This document provides details on a federal solicitation for cleaning and repainting bridge girders and resurfacing an approach roadway at the John H Kerr Dam in Mecklenburg County, Virginia. The U.S. Army Corps of Engineers, Wilmington District is seeking a contractor to clean and repaint the spillway bridge's 22 spans of steel girders using SSPC SP-5 blast cleaning and an epoxy paint system. The work also requires excavating the top six inches of concrete on the approach roadway across 19 non-overflow monoliths and replacing it with new concrete and reinforcing. The solicitation is a 100% small business set-aside with a magnitude between $1-5 million. The NAICS code is 237310 and bids must be registered in SAM. Interested parties should contact the contracting officers by July 28th for additional details.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLARKSVILLE
FINCHLEY
BOYDTON
US 15
US 58
BUS
US
B
YP
JOHN H KERR RESERVOIRUS 15
US 15
US 15
SR 1501 SR 1350
SR 1502
VA 825 VA 719
NC 39
VIRGINIA
NORTH CAROLINA
JOHN H KERR RESERVOIR
VA 825
US 58
US 58
VA 92
US 58
VA 707 VA
VA
US 58
VA 615
VA 4VA 615
VA 615
VA 678
VA 678
VA 70
VA 4
VA 4
VA 4
VA 707
BRIDGE AND
ROADWAY
REPAIR
JOHN H.
KERR DAM
ISSUE DATE:
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
Approval Recommended: *
Approved: *
07.28.22
07.28.22
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION
CHIEF, ENGINEERING BRANCH
* THIS PROJECT WAS DESIGNED BY THE U.S. ARMY CORPS OF ENGINEERS,
WILMINGTON DISTRICT. INDIVIDUALS WHOSE SIGNATURES AND REGISTRATION
DESIGNATIONS APPEAR ON THESE DOCUMENTS ARE OPERATING WITHIN THE
SCOPE OF THEIR EMPLOYMENT. SIGNATURES ARE REQUIRED BY ER 1110-1-8152.
CHIEF, DESIGN and GENERAL ENGINEERING SECTION
AND APPROVAL OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
G-000
C O
VE
R
S H
EE
T
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
PROJECT LOCATION, VICINITY MAP
N.T.S.
Wilmington DISTRICT
TBD
JULY 2022
W912PM22B0032
N
FY22 IIJA Bridge and Roadway Repair
JOHN H. KERR DAM AND RESERVOIR
MECKLENBURG COUNTY, VIRGINIA
RTA - READY TO ADVERTISE
INDEX OF DRAWINGS
SHEET NO. TITLE
G-000 COVER SHEET
G-001 GENERAL CONSTRUCTION NOTES
C-101 SITE PLAN
S-101 MAIN DAM PLAN & ELEVATIONS
S-102 SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION
S-103 NON-OVERFLOW MONOLITHS 1-9 INCL AND 42-53 INCL AND CUT-OFF WALL PLAN, ELEVATION, AND
SECTIONS
S-501 SPILLWAY MONOLITHS 20-40 INCL PIER DECK ARRANGEMENT SECTIONS AND DETAILS
S-502 STEEL SUPERSTRUCTURE CLEAN AND REPAINT PLANS AND SECTIONS
S-601 GIRDER REPAIR PHOTOS
REFERENCE DRAWINGS (ISSUED 1947)
GC 203A-2 MAIN DAM - PLAN, ELEVATIONS AND SECTIONS SHEET NO. 6
GE 808A-1 MAIN DAM - ELECTRICAL MONOLITHS 1-9 INCL. CONDUIT AND GROUNDING SHEET NO. 330
GE 815A-0 MAIN DAM - ELECTRICAL MONOLITHS 42-53 INCL. CONDUIT AND GROUNDING SHEET NO. 335
SC 200A-1 SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION SHEET NO. 42
SC270A-0 SPILLWAY MONOLITHS 19-41 INCL. BRIDGE - SHEET NO. 75
SS 200A-0 SPILLWAY MONOLITHS 19-41 INCL. BRIDGE ERECTION DIAGRAM AND GIRDER DETAILS
SHEET NO. 164
SS 201A-0 SPILLWAY MONOLITHS 19-41 INCL. BRIDGE FLOOR BEAMS SHEET NO. 165
SS 202A-0 SPILLWAY MONOLITHS 19-41 INCL. MISCELLANEOUS STRUCTURAL STEEL SHEET NO. 166
SS 203A-0 SPILLWAY MONOLITHS 19-41 INCL. HATCH FRAMES, COVERS AND JOINT FRAMES NO. 167
SS 204A-1 SPILLWAY MONOLITHS 19-41 INCL. CATWALK-ERECTION DIAGRAM AND DETAILS NO. 168
SS 205A-0 SPILLWAY MONOLITHS 19-41 INCL. CATWALK FRAMING NO. 169
SS 206A-0 SPILLWAY MONOLITHS 19-41 INCL. HATCH ARRANGEMENT NO. 170
SS 207A-0 SPILLWAY MONOLITHS 20-40 INCL. PIER DECK ARRANGEMENT NO. 171
NC 200A-0 NON-OVERFLOW MONOLITHS 1-9 INCL AND 42-53 INCL. AND CUT-OFF WALL SHEET NO. 37
NC 201A-0 NON-OVERFLOW MONOLITHS 1-8 INCL AND 42-53 INCL. SECTIONS & DETAILS SHEET NO. 38
NC 202A-0 NON-OVERFLOW MONOLITHS 9 INCL SECTIONS & DETAILS SHEET NO. 39
NOTICE TO CONTRACTOR - LEAD BASED
PAINT REMEDIATION REQUIRED.
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
AMENDMENTS:
0001 AUGUST 16, 2022
G-001
G
EN
ER
AL
C O
N
ST
R U
C
TI
O N
N O
TE
S
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
GENERAL NOTES
1. CLEANING AND REPAINTING OF BRIDGE STEEL GIRDERS AND FLOOR BEAM EXTENSIONS REQUIRES REMEDIATION OF LEAD BASED PAINT. REMEDIATION OF LEAD BASED PAINT SHALL FOLLOW THE
REQUIREMENTS IN ACCORDANCE WITH SPECIFICATION SECTION 02 83 00. PROTECTION OF
EXISTING FACILITY SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION 01 10 00.10 38.
REPAINTING OF THE BRIDGE STEEL GIRDERS AND FLOOR BEAM EXTENSIONS SHALL FOLLOW THE
REQUIREMENTS IN ACCORDANCE WITH SPECIFICATION SECTION 09 97 02.
2. ALL ELEVATIONS AND DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE WORK BEGINS. THE
CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL DIMENSIONS PRIOR TO SHOP DRAWING
PREPARATIONS AND MATERIAL FABRICATION.
3. THE CONTRACTOR SHALL MAINTAIN WALKWAY ACCESS FOR THE ENTIRE LENGTH OF THE DAM FOR
DAILY DAM GATE SETTINGS OPERATIONS.
4. GOVERNMENT UTILITIES (INCLUDING WATER, FUEL, ETC) AND EQUIPMENT WILL NOT BE MADE AVAILABLE TO THE CONTRACTOR. ELECTRIC UTILITIES WILL BE PROVIDED BY THE GOVERNMENT.
5. REFERENCE DRAWINGS ARE DRAWINGS OF RECORD, INCLUDED SOLELY FOR THE CONTRACTOR'S BENEFIT. NO REQUIRED WORK UNDER THIS CONTRACT IS SHOWN ON THE REFERENCE DRAWINGS.
THE REFERENCE DRAWINGS ARE NOT "AS-BUILTS" DO NOT NECESSARILY REPRESENT ACTUAL
FIELD CONDITIONS. REFERENCE DRAWINGS ARE NOT PRINTED TO SCALE.
6. CONTRACTOR SHALL INCLUDE A GENERAL SEQUENCE OF WORK WHICH INCLUDES BUT IS NOT
LIMITED TO ABRASIVE BLASTING AND PAINTING, AND PROTECTION OF NON PAINTED ELECTRICAL
AND MECHANICAL FEATURES.
7. LEAD BASE PAINT IS PRESENT ON THE EXISTING STEEL GIRDERS.
8. LAKE ELEVATIONS SHOWN ON PLAN SHEETS VARY. NORMAL POOL IS EL 300.0'. REFER TO
RIVER-GAGES FOR HISTORIC RIVER LEVELS.
CONCRETE:
1. VERY-EARLY STRENGTH LATEX-MODIFIED CONCRETE OVERLAY (LMC-VES) SHALL BE PLACED IN
ACCORDANCE WITH ACI 548.40-11 AND VDOT ROAD AND BRIDGE SPECIFICATIONS.
2. BEFORE PLACING THE OVERLAY, THE SURFACE SHALL BE SHOTBLASTED OR HYDROBLASTED WITH EQUIPMENT TO PROVIDE A MACROTEXTURE DEPTH OF AT LEAST 0.06 INCH (ASTM E 965) OVER THE
AREA TO BE OVERLAID WITHIN THE TIME ALLOWED FOR SURFACE PREPARATION. CONTRACTOR
TO PROVIDE A MINIMUM 5-FT X 5-FT TEST AREA FOR REVIEW AND APPROVAL BY THE CONTRACTING
OFFICER PRIOR TO PLACEMENT OF LMC-VES.
3. THE OVERLAY CONCRETE SHALL BE MOIST CURED FROM THE TIME IT IS PLACED UNTIL IT IS
OPENED TO TRAFFIC.
4. THE MOIST CURE SHALL BE INITIATED BY APPLYING WET BURLAP AND PLASTIC TO THE SURFACE OF THE OVERLAY CONCRETE AS SOON AS PRACTICAL AND BEFORE THE SURFACE DRIES. SECURE
BURLAP/PLASTIC TO PREVENT IT FROM BEING BLOWN AWAY OR DISPLACED. MOISTURE CURE
COVER SYSTEM TO REMAIN IN PLACE UNTIL 3500 PSI COMPRESSIVE STRENGTH IS OBTAINED.
5. COMPRESSIVE STRENGTH, MINIMUM, PSI CONCRETE ASTM C39:
· 3 HOURS: 2500
· 1 DAY: 3500
· 28 DAYS: 3500
6. BOND STRENGTH, MINIMUM, PSI, VTW 92:
· 7 DAYS: 150 PSI.
TRAFFIC CONTROL NOTES
1. JOHN H KERR DAM CARRIES VIRGINIA HIGHWAY 4 ACROSS THE TOP OF THE DAM. CONSTRUCTION ACTIVITY SHALL BE PHASED TO ALLOW AT LEAST ONE-LANE TRAVEL ACROSS THE TOP OF THE DAM
WITH A MINIMUM LANE WIDTH OF 11 FEET.
2. CONTRACTOR SHALL SUBMIT A DETAILED TRAFFIC CONTROL PLAN ADDRESSING THE TRAFFIC
DISRUPTING CONSTRUCTION ACTIVITIES AND PLANNED MEASURES FOR MEETING THE ABOVE
REQUIREMENTS. THE TRAFFIC CONTROL PLAN MUST BE SEALED BY A PROFESSIONAL TRAFFIC
ENGINEER LICENSED IN THE STATE OF VIRGINIA AND APPROVED BY THE CONTRACTING OFFICER
OR THE CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE PRIOR TO ANY WORK.
3. THE TRAFFIC CONTROL PLAN SHALL BE DEVELOPED IN ACCORDANCE WITH THE CURRENT
VERSION OF THE VDOT "WORK AREA PROTECTION MANUAL". THE TRAFFIC CONTROL PLAN SHALL BE REVIEWED BY AND COORDINATED WITH PERMITS DEPARTMENT OF THE VDOT OFFICE LOCATED
IN SOUTH HILL, VIRGINIA.
4. IN THE CASE OF ONE-WAY TRAVEL LANES, TRAFFIC CONTROL MEASURES SHALL BE IMPLEMENTED
TO PROVIDE SAFE TRAVEL THROUGH THE ONE-WAY PORTIONS. FLAGGING OPERATIONS AND
SIGNAGE SHALL CONFORM TO VDOT STANDARD DRAWINGS, CURRENT VERSION.
5. TWO-WAY, TWO LANE TRAFFIC SHALL BE MAINTAINED DURING PERIODS OF CONSTRUCTION
INACTIVITY. A PERIOD OF CONSTRUCTION INACTIVITY IS DEFINED AS A PERIOD EQUAL TO OR
GREATER THAN ONE WEEK..
6. CONTRACTOR SHALL SUPPLY SIGNAGE IN ACCORDANCE WITH VDOT STANDARD DRAWINGS,
CURRENT EDITION, ALONG VA HWY 4.
7. THE CONTRACTOR SHALL MAINTAIN TRAFFIC DURING CONSTRUCTION AND PROVIDE, INSTALL, AND MAINTAIN ALL TRAFFIC CONTROL DEVICES IN ACCORDANCE WITH THESE PROJECT GUIDELINES, THE PROJECT SPECIAL PROVISIONS, VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARD
DRAWINGS, STANDARD SPECIFICATIONS FOR ROAD AND STRUCTURE CURRENT EDITION, AND THE
CURRENT EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).
8. THE CONTRACTOR SHALL UTILIZE COMPLETE AND PROPER TRAFFIC CONTROLS AND TRAFFIC
CONTROL DEVICES DURING ALL OPERATIONS. ALL TRAFFIC CONTROL AND TRAFFIC CONTROL
DEVICES REQUIRED FOR ANY OPERATION SHALL BE FUNCTIONAL AND IN PLACE PRIOR TO THE
COMMENCEMENT OF THAT OPERATION. SIGNS FOR TEMPORARY OPERATION SHALL BE REMOVED
DURING PERIODS OF INACTIVITY. THE CONTRACTOR IS REQUIRED TO LEAVE THE PROJECT IN A
MANNER THAT WILL BE SAFE TO THE TRAVELING PUBLIC AND WHICH WILL NOT IMPEDE
MOTORISTS.
9. TRAFFIC MOVEMENTS THROUGH LANE CLOSURES ON ROADS WITH TWO WAY TRAFFIC SHALL BE CONTROLLED BY FLAGGERS STATIONED AT EACH END OF THE WORK ZONE. IN SITUATIONS WHERE
SIGHT DISTANCE IS LIMITED, THE CONTRACTOR SHALL PROVIDE ADDITIONAL MEANS OF
CONTROLLING TRAFFIC, INCLUDING, BUT NOT LIMITED TO, TWO-WAY RADIOS, PILOT VEHICLES, OR
ADDITIONAL FLAGGERS. FLAGGER SHALL BE COMPETENT PERSONNEL, ADEQUATELY TRAINED IN
FLAGGING PROCEDURE, AND FURNISHED WITH PROPER SAFETY DEVICES AND EQUIPMENT,
INCLUDING, BUT NOT LIMITED TO, SAFETY VESTS AND STOP/SLOW PADDLES.
10. ALL PERSONNEL, WHEN WORKING IN TRAFFIC AREAS OR AREAS IN CLOSE PROXIMITY TO TRAFFIC, SHALL WEAR AN APPROVED SAFETY VEST, OR SHIRT OR JACKET WHICH MEETS THE COLOR
REQUIREMENTS OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).
11. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, AND REGULATIONS GOVERNING SAFETY, HEAL TH, AND SANITATION, AND SHALL
PROVIDE ALL SAFEGUARDS, SAFETY DEVICES, AND PROTECTIVE EQUIPMENT, AND SHALL TAKE
ANY OTHER NEEDED ACTIONS, ON HIS OWN RESPONSIBILITY THAT ARE REASONABLY NECESSARY TO PROTECT THE LIFE AND HEALTH OF EMPLOYEES ON THE JOB AND THE SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF THE WORK COVERED
BY THE CONTRACTOR.
12. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT PROPER TRAFFIC CONTROL PROVISIONS AND ANY DEVICES REQUIRED TO IDENTIFY OBSTRUCTIONS OR HAZARDS WITHIN THE ROADWAY TO INCLUDE REFLECTIVE CONES AT EACH OPEN CUT / GRAVEL FILLED TRENCH, REFLECTIVE BARRELS
ON RAISED MANHOLES, ETC.
13. WHEN PHYSICAL DIMENSIONS IN THE DETAIL DRAWINGS, STANDARD DETAILS, AND ROADWAY DETAILS ARE NOT ATTAINABLE TO MEET FIELD CONDITIONS OR WHEN THEY RESULT IN DUPLICATE
OR UNDESIRED OVERLAPPING OF DEVICES, CHANGES MAY BE REQUIRED. MODIFICATIONS MAY
INCLUDE: MOVING, SUPPLEMENTING, COVERING, OR REMOVAL OF DEVICES AS DIRECTED BY THE
CONTRACTING OFFICER OR DESIGNATED REPRESENTATIVE.
14. THE CONTRACTOR SHALL COVER OR REMOVE ALL SIGNS AND DEVICES REQUIRED FOR LANE
CLOSURE WHEN THE LANE CLOSURE IS NOT IN OPERATION.
15. ANY WORK REQUIRING EQUIPMENT OR PERSONNEL WITHIN 5-FEET OF THE EDGE OF THE TRAVEL
LANE SHALL REQUIRE A LANE CLOSURE WITH APPROPRIATE TAPERS.
16. DURING NON-WORKING HOURS, EQUIPMENT SHALL BE PARKED AS FAR FROM THE ROADWAY AS
POSSIBLE AND SHALL BE PROPERLY BARRICADED SO THAT NO EQUIPMENT OBSTRUCTION SHALL
BE WITHIN THE CLEAR RECOVERY AREA.
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
12 MONOLITHS
@ 50' = 600'
29.0'
22 GATES @ 42' PLUS 21 PIERS @ 8' = 1092'
43.0'
6 MONOLITHS
@ 70' = 427'
9 MONOLITHS
@ 50' = 453'
ST
A
+6 4.
ST
A
+1 4.
ST
A
+6 6.
ST
A
+6 0.
ST
A
+5 0.
N
C-101
SI
TE
P
LA
N
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
SCALE: 1" = 250'-0"1 SITE PLAN
BU
G
G
S ISLAN
D R
D
BUGGS ISLAND RD. 4
BU
G
G S
IS
LA
ND
R
D.
MAYS C
HAPEL R
D.
FL
O
W
STAGING AREA FOR
CONTRACTOR
LOADING AREA FOR
THIS CONTRACT
1 2
WEST SIDE
EAST SIDE
S-101
M
AI
N D
AM
PL
AN
E
LE
VA
TI
O
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
SCALE: 1" = 100'-0"B UPSTREAM ELEVATION
GRAPHIC SCALE
1" = 100'
100'0 200'50'
SCALE: 1" = 100'-0"A DOWNSTREAM ELEVATION
SCALE: 1" = 100'-0"1 PLAN
A
S-101
B
S-101
EAST SIDEWEST SIDE
EAST SIDE WEST SIDE
EAST SIDE WEST SIDE
GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS.
2. LAYOUT OF DAM, MONOLITHS, AND BRIDGE BASED ON REFERENCE DRAWINGS:
· FILE NO. GC203A-2 - SHEET NO. 6 - MAIN DAM PLAN, ELEVATIONS AND SECTIONS - OCTOBER 1947.
· FILE NO. SC200A-1 - SHEET NO. 42 - SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION - AUGUST 1947.
· FILE NO. NC200A-0 - SHEET NO. 37 - NON-OVERFLOW MONOLITHS 1-9 INCL AND 42-53 INCL AND CUT-OFF WALL - SEPTEMBER 1947.
· FILE NO. NC201A-0 - SHEET NO. 38 - NON-OVERFLOW MONOLITHS 1-8 INCL AND 42-53 SECTIONS AND DETAILS - OCTOBER 1947.
S-501
TYP.
S-501
TYP.
S-102
SP
IL
LW
AY
M O
N O
LI
TH
S
-4
IN
C
L.
PL
AN
A
N D
S
EC
TI
O
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
SCALE: 1" = 60'-0"A DOWNSTREAM SECTION
SCALE: 1" = 60'-0"1 PLAN
S-102
A
S-102
A
GRAPHIC SCALE
1" = 60'
60'0 120'30'
EAST SIDE WEST SIDE
EAST SIDE WEST SIDE
GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS.
2. LAYOUT OF DAM, MONOLITHS, AND BRIDGE BASED ON REFERENCE DRAWINGS:
· FILE NO. GC203A-2 - SHEET NO. 6 - MAIN DAM PLAN, ELEVATIONS AND SECTIONS
- OCTOBER 1947.
· FILE NO. SC200A-1 - SHEET NO. 42 - SPILLWAY MONOLITHS 19-41 INCL. PLAN AND
SECTION - AUGUST 1947.
· FILE NO. NC200A-0 - SHEET NO. 37 - NON-OVERFLOW MONOLITHS 1-9 INCL AND
42-53 INCL AND CUT-OFF WALL - SEPTEMBER 1947.
· FILE NO. NC201A-0 - SHEET NO. 38 - NON-OVERFLOW MONOLITHS 1-8 INCL AND
42-53 SECTIONS AND DETAILS - OCTOBER 1947.
S-501
TYP.
S-501
TYP.
ROADWAY REPAIR ROADWAY REPAIR
MONOLITH JOINTS (TYP.) - ROADWAY
REPAIR WILL NEED TO MAINTAIN
JOINTS AT ALL MONOLITH JOINTS.
MONOLITH JOINTS (TYP.) - ROADWAY
REPAIR WILL NEED TO MAINTAIN
JOINTS AT ALL MONOLITH JOINTS.
11'-7 1/2"
10'-0"
11'-7 1/2"
BRIDGE ROADWAY
OVER MONOLITHS
CL OF
ROADWAY
EL. 330.00'
EL. 331.83'
EL. 334.79'
EL. 326.00'
4'-0" 1'-0"1'-0"
1'-0"
MONOLITHS
SAW-CUT FOR
REPAIR - SEE
4/S-103 (TYP.)
REMOVE CONCRETE PAVEMENT TO LIMITS
SHOWN BY SHADED AREA. CONCRETE MAY BE
REMOVED BY SAW-CUTTING OR MILLING. IMPACT
HAMMERS AND RAMS WILL NOT BE PERMITTED.
SAW-CUT FOR
REPAIR - SEE
4/S-103 (TYP.)
11'-7 1/2"11'-7 1/2"
CL OF
ROADWAY
EL. 330.00'
EL. 336.50'
3'-9" 1'-6"1'-0"
1'-6"
MONOLITHS
BRIDGE ROADWAY
OVER MONOLITHS
SAW-CUT FOR
REPAIR - SEE
4/S-103 (TYP.)
REMOVE CONCRETE PAVEMENT TO LIMITS
SHOWN BY SHADED AREA. CONCRETE MAY BE
REMOVED BY SAW-CUTTING OR MILLING. IMPACT
HAMMERS AND RAMS WILL NOT BE PERMITTED.
SAW-CUT FOR
REPAIR - SEE
4/S-103 (TYP.)
NOTES:
1. W = APPROX. 0'-6", EXTEND OVER SEVERAL SLABS IF NECESSARY.
2. H = 0'-2", MINIMUM.
3. H' = H + 0'-2", MAXIMUM OF 0'-4".
4. VERY-EARLY STRENGTH LATEX-MODIFIED CONCRETE OVERLAY
(LMC-VES) SHALL BE PLACED IN ACCORDANCE WITH ACI 548.40-11
AND VDOT ROAD AND BRIDGE SPECIFICATIONS, SEE GENERAL
NOTES FOR MORE INFORMATION.
CL OF
ROADWAY
1' -1
0"
EL. 330.00'
EL. 331.83'
H
W
H
BRIDGE RAIL, SIDEWALK &
CURB
SAW CUT FACE
NEW CONCRETE
OVERLAY
W
T/CONC.
NOTE: MATCH EXISTING JOINTS AND CUT INTERMEDIATE
JOINTS AS NEEDED.
NEW CONCRETE
OVERLAY
EXPANSION JOINT
MATERIAL H
EXISTING
CONCRETE JOINT
EXISTING
CONCRETE SLAB
S-103
N O
N -O
VE
R
FL
O
W M
O N
O
LI
TH
S
1-
IN
C
L
AN
D
2-
IN
C
L
AN
D C
U T-
O
FF
W
AL
L
PL
AN
, E
LE
VA
TI
O
N , A
N D
S
EC
TI
O
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
SCALE: 1" = 60'-0"A DOWNSTREAM ELEVATION
SCALE: 1" = 60'-0"1 PLAN
BASE BID ITEM
APPROACH ROADWAY RESURFACING OF MONOLITHS:
1, 2, 3, 4, 5, 47, 48, 49, 50, 51, 52, AND 53
OPTIONAL BID ITEM
APPROACH ROADWAY RESURFACING OF MONOLITHS:
7, 8, 9, 42, 43, 44, 45, AND, 46
GRAPHIC SCALE
1" = 60'
60'0 120'30'
A
S-103
GRAPHIC SCALE
1" = 5'
5'0 10'2.5'
SCALE: 1" = 5'-0"2 ROADWAY SECTION AT MONOLITHS 02 - 09 and 42 - 52
EAST SIDE WEST SIDE
EAST SIDE WEST SIDE
SCALE: 1" = 5'-0"3 REPAIR ROADWAY SECTION AT MONOLITHS 01 & 53
SCALE: 1" = 5'-0"4 REPAIR SECTION
GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS.
2. COVER PLATES FOR ELECTRICAL BOXES ARE IN THE PAVEMENT SURFACE OF MONOLITHS 2, 5, 8, 44, 47, 50, AND 53. SEE
REFERENCES DRAWINGS GE 808AA AND GE 815A.
3. LAYOUT OF DAM, MONOLITHS, AND BRIDGE BASED ON REFERENCE DRAWINGS:
· FILE NO. GC203A-2 - SHEET NO. 6 - MAIN DAM PLAN, ELEVATIONS AND SECTIONS - OCTOBER 1947.
· FILE NO. SC200A-1 - SHEET NO. 42 - SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION - AUGUST 1947.
· FILE NO. NC200A-0 - SHEET NO. 37 - NON-OVERFLOW MONOLITHS 1-9 INCL AND 42-53 INCL AND CUT-OFF WALL - SEPTEMBER 1947.
· FILE NO. NC201A-0 - SHEET NO. 38 - NON-OVERFLOW MONOLITHS 1-8 INCL AND 42-53 SECTIONS AND DETAILS - OCTOBER 1947.
S-103
S-103
TYP.
S-103
S-103
TYP.
424344454647484950515253 23456789 1
SCALE: 1" = 5'-0"5 JOINT DETAIL
TOP SURFACE ELEVATION OF NEW CONCRETE OVERLAY TO
MATCH TOP SURFACE ELEVATION OF EXISTING CONCRETE.
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
1 1
EXISTING GIRDER
EXISTING FLOOR
BEAM EXTENSION
EXIST. ROADWAY
RAIL
EXIST. ROADWAY
EXISTING GIRDER
EXISTING FLOOR
BEAM EXTENSION
EXIST. ROADWAY
RAIL
EXIST. FLOOR
BEAM
45'-4" OUT to OUT
10'-2"10'-2"2'-4"
CL SYMMETRICAL101
2"21
2" 1'-01 4" 3'-4" 3'-6" 3'-4" 3'-4"3'-6"3'-4"
4"
(2 )L
7x 4x
(2) FILL PLATE
15 12" x 916"
PLATE 16" x 916" x 1'-6"
CL FLOOR BEAM
FILL PLATE 11" x 516"
NEAR SIDE
FILL PLATE 4" x 916"
FAR SIDE
(2 )L
7x 4x
C R
IM
PE
D
(2)L8x6x9
(TYP. U.N.O.)
WEB PLATE
42" x 12"
(TYP. U.N.O.)(2
)L
7x 4x
C R
IM
PE
D
FILL PLATE
11" x 516"
NEAR SIDECOVER PLATE
18" x 716" x 31'-9"
FI
LL
P
LA
TE
" x 9 16
FA
R S
ID
E
(2 ) L
7x 4x
COVER PLATE
18" x 3 8" x 24'-6"
(2 )L
7x 4x
C R
IM
PE
D
(2 )L
7x 4x
C R
IM
PE
D
FILL PLATE
11" x 516"
NEAR SIDE
FI
LL
P
LA
TE
" x 9 16
FA
R S
ID
E
(2 ) L
7x 4x
4/A-A
S-501
4/B-B
S-501
4/C-C
S-501
(2)L8x6x9
(TYP. U.N.O.)
3' -6
1 2"
AREA AT END OF GIRDER TO BE
CLEANED AND REPAINTED (SEE
TYPICAL CONDITIONS IN PHOTOS
ON SHEET S-502)
AREA AT END OF GIRDER TO BE
CLEANED AND REPAINTED (SEE
TYPICAL CONDITIONS IN PHOTOS
ON SHEET S-502)
EXISTING STEEL FRAME ON PIER
SIDE F EXPANSION JOINT
EXISTING FILLS (UNDER
TIE PLATE)
EXISTING TIE PLATE
EXISTING GIRDER
EXISTING FLOOR BEAM
EXTENSION
EXISTING STEEL
FRAME ON PIER SIDE
EXIST. MASONRY
SUPPORT ANGLE
FLOOR BEAM EXTENSION TO BE CLEANED AND
REPAINTED (SEE TYPICAL CONDITIONS IN
PHOTOS ON SHEET S-502)
EXIST. ROADWAY
RAIL
DETAIL A-A
(2) FILL PLATE
15 12" x 916"
PLATE 16" x 916" x 1'-6"
L7x4x3
PLATE 16" x 916" x 1'-6"
L8x6x9
L8x6x9
(2) FILL PLATE
15 12" x 916"
L7x4x3
L8x6x9
L8x6x9
DETAIL B-B
(2) FILL PLATE
15 12" x 916"
L7x4x3
L8x6x9
L8x6x9
DETAIL C-C
14WF61
(SPLIT)
GROUT
GROUT
EXISTING
MASONRY PLATE
EXISTING
ANCHOR BOLT
EXISTING HATCH FRAME MK 19
AXIS OF DAM
EXISTING HATCH COVER
EXISTING HATCH FRAME
EXISTING GIRDER
EXISTING
MASONRY PLATE
EXISTING ANCHOR
BOLT
EXISTING FLOOR BEAM EXISTING GIRDER
2'-3"
36'-6"
EXISTING HATCH COVER
FLOW
S-501
SP
IL
LW
AY
M O
N O
LI
TH
S
-4
IN
C
L
PI
ER
D
EC
K
AR
R
AN
G
EM
EN
T
SE
C
TI
O N
S
AN
D D
ET
AI
LS
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
GENERAL CONSTRUCTION NOTES
1. THE FIVE FEET ON EACH END OF THE SUPER STRUCTURE STEEL
GIRDERS, INCLUDING THE FLOOR BEAMS EXTENSIONS ON EACH
END OF THE GIRDER AND THE GIRDER BEARING PLATES SHALL
BE ABRASIVE BLASTED AND PAINTED IN ACCORDANCE WITH
SECTION 09 97 02 OF THE SPECIFICATIONS.
2. ALL STEEL BRIDGE MEMBERS SHOWN ON THE SECTIONS AND
ELEVATIONS ARE EXISTING (SEE NOTE 8). NO NEW STEEL OR
STEEL REPAIRS ARE REQUIRED UNDER THIS CONTRACT.
3. ALL EXISTING PAINT IS LEAD BASED. SEE SPECIFICATION 09 97 02.
4. BRIDGE PAINTING RELATED WORK: - SEE G001 NOTE #1 AND
SPECIFICATION 09 97 02.
5. THE APPROXIMATE SURFACE AREA TO BE CLEANED AND PAINTED
OF EACH OF THE 22 SPANS AND FLOOR BEAM EXTENSIONS IS 400
SF FOR A TOTAL OF 8,800 SF. (SURFACE AREA OF BRIDGE STEEL
TO BE CLEANED AND PAINTED IS ESTIMATED AND IS PROVIDED
FOR BIDDING PURPOSES ONLY).
6. FIELD VERIFY ALL DIMENSIONS.
7. CONTRACTOR TO PROVIDE WORK PLATFORMS TO ACCESS TO
SUPERSTRUCTURE GIRDERS IN ACCORDANCE WITH
SPECIFICATION SECTION 01 35 26.
8. CONTRACTOR TO PROVIDE CONTAINMENT OF LEAD BASED PAINT
AND BLAST MATERIAL IN ACCORDANCE WITH SPECIFICATION
SECTIONS 02 83 00 AND 09 97 02.
9. LAYOUT OF DAM, MONOLITHS, AND BRIDGE BASED ON
REFERENCE DRAWINGS:
· FILE NO. GC203A-2 - SHEET NO. 6 - MAIN DAM PLAN, ELEVATIONS
AND SECTIONS - OCTOBER 1947.
· FILE NO. SC200A-1 - SHEET NO. 42 - SPILLWAY MONOLITHS 19-41
INCL. PLAN AND SECTION - AUGUST 1947.
· FILE NO. NC200A-0 - SHEET NO. 37 - NON-OVERFLOW MONOLITHS
1-9 INCL AND 42-53 INCL AND CUT-OFF WALL - SEPTEMBER 1947.
· FILE NO. NC201A-0 - SHEET NO. 38 - NON-OVERFLOW MONOLITHS
1-8 INCL AND 42-53 SECTIONS AND DETAILS - OCTOBER 1947.
SCALE: 1/2" = 1'-0"2 SECTION C-C
GRAPHIC SCALE
1/2" = 1'-0"
0 1' 2' 4'
SCALE: 1/2" = 1'-0"5 SECTION E-E
SCALE: 1/2" = 1'-0"3 ELEVATION GIRDER (MARK G1 & G2)
SCALE: 1/2" = 1'-0"4 DETAILS - GIRDER
LEGEND
CLEAN AND REPAINT
S-501
3 SIM
SCALE: 1/2" = 1'-0"1 SECTION B-B
S-501
3 SIMS-501
3 SIM
S-501
3 SIM
S-501
5 TYP
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
EXIST. HATCH
EXIST. ROADWAY RAIL
EXIST. ROADWAY
EXIST. ROADWAY RAIL
EXIST. HATCH
EXISTING FLOOR BEAM (TYP.)
EXISTING GIRDER
EXIST. ROADWAY
EXIST. ROADWAY RAIL
EXISTING FLOOR BEAM (TYP.) EXISTING GIRDER
EXIST. ROADWAY RAIL
EXISTING GIRDER
EXISTING FLOOR
BEAM EXTENSION
EXIST. ROADWAY
RAIL
EXIST. ROADWAY
EXIST. ROADWAY
RAIL
EXIST. FLOOR
BEAM
EXIST. FRAME
EXISTING FLOOR
BEAM EXTENSION
EXISTING GIRDER
S-502
ST
EE
L
SU
PE
R
ST
R
U C
TU
R
E C
LE
AN
A N
D R
EP
AI
N T
PL
AN
S
SE
C
TI
O
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
GENERAL CONSTRUCTION NOTES
1. BRIDGE PAINTING RELATED WORK: - SEE G001 NOTE #1 AND
SECTION 09 97 02 OF THE SPECIFICATIONS.
2. ALL EXISTING PAINT IS LEAD BASED. CONTRACTOR TO PROVIDE
CONTAINMENT OF LEAD BASED PAINT AND BLAST MATERIAL IN
ACCORDANCE WITH SPECIFICATION SECTIONS 02 83 00 AND 09 97
02.
3. LOCATION OF THE STEEL SUPERSTRUCTURE TO BE CLEANED AND
REPAINTED ARE IDENTIFIED ON THE “PLAN - TYPICAL SPAN” AS 1,
2, 3, AND 4. THERE ARE 22 SPANS AND EACH SPAN HAS TWO
GIRDERS.
4. GIRDERS - CLEAN AND PAINT 5-FEET OF THE EAST END AND
5-FEET OF THE WEST END OF EACH GIRDER. THERE ARE 44
GIRDERS. THE LOCATIONS ARE THE END FIVE FEET OF THE TWO
GIRDERS OF EACH SPAN AS SHOWN ON “SECTION A-A” AND
“ELEVATION C-C”. THE SURFACES TO BE CLEANED AND PAINTED
ARE THE SOUTH AND NORTH WEB, AS WELL AS THE BOTTOM AND
TOP FLANGES. THE TOPSIDE OF THE TOP FLANGE CAN BE
EXCLUDED DUE TO SPACE LIMITATIONS OF THE BOTTOM OF THE
CONCRETE DECK.
5. FLOOR BEAM EXTENSIONS - CLEAN AND PAINT FLOOR BEAM
EXTENSIONS ON THE UPSTREAM AND DOWNSTREAM SIDES OF
THE GIRDERS AS SHOWN IN “SECTION B-B”. THE TWO FLOOR BEAM
EXTENSIONS THAT ARE LOCATED WITHIN THE END FIVE FEET OF
EACH GIRDER ARE TO BE CLEANED AND PAINTED. BOTH THE EAST
AND WEST SIDE, AS WELL AS THE TOP AND BOTTOM FLANGES OF
THE FLOOR BEAM EXTENSIONS ARE TO BE CLEANED AND PAINTED.
6. IN ADDITION TO THE GIRDER AND FLOOR BEAM EXTENSIONS, THE
GIRDER BEARING PLATES ARE TO BE CLEANED AND PAINTED.
7. FIELD VERIFY ALL DIMENSIONS.
8. LAYOUT OF DAM, MONOLITHS, AND BRIDGE BASED ON REFERENCE
DRAWINGS:
· FILE NO. SC270A-0 - SHEET NO. 75 - SPILLWAY MONOLITHS 19-41
INCL. - BRIDGE - AUGUST 1947.
LEGEND
CLEAN AND REPAINT
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
SCALE: 3/8" = 1'-0"4 SECTION B - B
SCALE: 1/4" = 1'-0"1 PLAN - TYPICAL SPAN
SCALE: 1/4" = 1'-0"3 SECTION C - C
SCALE: 1/4" = 1'-0"2 SECTION A - A
S-601
G
IR
D
ER
R
EP
AI
R
PH
O
TO
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
AN
SI
D
XX
XX
XX
-X
X- X-
XX
XX
W
2P M
B0
JU
LY
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
D
IS
TR
IC
T
R
TA
- R
EA
D Y
TO
A
D
VE
R
TI
SE
FY
II
JA
B rid ge R oa dw ay R ep ai r
JO
H N
H . K
ER
R
D
AM
A N
D R
ES
ER
VO
IR
M
EC
KL
EN
BU
R
G C
O U
N
TY
, V
IR
G
IN
IA
J.
M
AN
N
IN
G
H . W
IL
D
E
S.
S
U R
R
AT
T
E.
D
U N
LO
P/
A.
K
AP
TI
S
GENERAL CONSTRUCTION NOTES
1. THE PHOTOS ARE SHOWN FOR VISUAL REPRESENTATION OF THE STEEL
GIRDERS AND FLOOR BEAM EXTENSIONS TO BE CLEANED AND PAINTED
FOR BIDDING PURPOSES.
PHOTO 1: Left Pier Support of Girder (Typical), taken from Catwalk.
PHOTO 2: Typical Roadway Extension Plate, right side looking downstream.
PHOTO 3: Corroded Roadway Extension Plate, right side looking downstream.
PHOTO 4: Upstream view of girder looking from left, upstream side, typical.
PHOTO 5: Corroded Stiffener at bearing plate, left, upstream side of girder (typical).
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
A
U G
| GENERAL |
| G000 COVER SHEET |
| G001 GENERAL NOTES |
| CIVIL |
| C-101 SITE PLAN |
| STRUCTURAL |
| S-101 MAIN DAM PLANS & ELEVATIONS |
| S-102 SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION |
| S-103 NON-OVERFLOW MONOLITHS 1-9 INCL. AND 42-53 INCL AND CUT-OFF WALL PLAN, ELEVATION, AND SECTIONS |
| S-501 SPILLWAY MONOLITHS 20-40 INCL PIER DECK ARRANGEMENT SECTIONS AND DETAILS |
| S-502 STEEL SUPERSTRUCTURE CLEAN AND REPAINT PLANS AND SECTIONS |
| S-601 GIRDER REPAIR PHOTOS |
| Reference Drawings |
| GC 203A-2 MAIN DAM - PLAN, ELEVATIONS AND SECTIONS SHEET NO. 6 |
| SC 200A-1 SPILLWAY MONOLITHS 19-41 INCL. PLAN AND SECTION SHEET NO. 42 |
| GE 808A-1 MAIN DAM - ELECTRICAL MONOLITHS 1-9 INCL. CONDUIT AND GROUNDING SHEET NO. 330 |
| GE 815A-0 MAIN DAM - ELECTRICAL MONOLITHS 42-53 INCL. CONDUIT AND GROUNDING SHEET NO. 335 |
| SS 200A-0 SPILLWAY MONOLITHS 19-41 INCL. BRIDGE ERECTION DIAGRAM AND GIRDER DETAILS SHEET NO. 164 |
| SS 201A-0 SPILLWAY MONOLITHS 19-41 INCL. BRIDGE FLOOR BEAMS SHEET NO. 165 |
| SS 202A-0 SPILLWAY MONOLITHS 19-41 INCL. MISCELLANEOUS STRUCTURAL STEEL SHEET NO. 166 |
| SS 203A-0 SPILLWAY MONOLITHS 19-41 INCL. HATCH FRAMES, COVERS AND JOINT FRAMES NO. 167 |
| SS 204A-1 SPILLWAY MONOLITHS 19-41 INCL. CATWALK-ERECTION DIAGRAM AND DETAILS NO. 168 |
| SS 205A-0 SPILLWAY MONOLITHS 19-41 INCL. CATWALK FRAMING NO. 169 |
| SS 206A-0 SPILLWAY MONOLITHS 19-41 INCL. HATCH ARRANGEMENT NO. 170 |
| SS 207A-0 SPILLWAY MONOLITHS 20-40 INCL. PIER DECK ARRANGEMENT NO. 171 |
| NC 200A-0 NON-OVERFLOW MONOLITHS 1-9 INCL AND 42-53 INCL. AND CUT-OFF WALL SHEET NO. 37 |
| NC 201A-0 NON-OVERFLOW MONOLITHS 1-8 INCL AND 42-53 INCL. SECTIONS & DETAILS SHEET NO. 38 |
| NC 202A-0 NON-OVERFLOW MONOLITHS 9 INCL SECTIONS & DETAILS SHEET NO. 39 |