W912PL21B0002_Amendment0003.pdf

PDF 15 MB Posted

Attached to
FY18 Ground Transport Equipment Facility Federal contract opportunity
Solicitation number
W912PL21B0002
Issued by
Department of the Army Corps of Engineers Engineering District Los Angeles

About this file

This solicitation is for the construction of a Ground Transport Equipment Facility at Fort Huachuca, Arizona. Services required include the construction of a vehicle maintenance shop, organizational storage building, vehicle wash platform, vehicle loading dock, petroleum, oils and lubricants storage, hazardous waste storage, and demolition of three existing buildings totaling 10,072 square feet. The project is based on the medium-sized Tactical Equipment Maintenance Facility standard but customized for the customer's functions. Estimated costs range from $25-100 million. The NAICS code is 236220. The solicitation will be issued under full and open competition without exclusion of sources. The Department of the Army Corps of Engineers Engineering District Los Angeles is the issuing agency.

View the file

Other files for this federal contract opportunity

Other files attached to FY18 Ground Transport Equipment Facility, newest first.
File Type Posted
Bid Abstract W912PL-20-B-0002.pdf PDF
W912PL21B0002_Amendment0005.pdf PDF
W912PL21B0002_Amendment0004.pdf PDF
W912PL21B0002_Amendment0002.pdf PDF
W912PL21B0002_Amendment0001.pdf PDF
Site Visit Sign In.pdf PDF
Plans_W912PL21B0002_Ft Huachuca.pdf PDF
Spec_W912PL21B0002_Ft Huachuca_AZ.pdf PDF
Plans_W912PL21B0002_Ft Huachuca.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICAITON NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicble)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICIATION NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a)By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPIRATION DATA (If required)

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc. ) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION ( Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

0003 27 OCT 2020

W912PL

U.S Army Corps of Engineers,Los Angeles Dist CESPL-CT-E, East Region Branch 915 Wilshire Blvd.

Los Angeles, CA 90017

SEE ITEM 6

W912PL-21-B-0002

18 September2020

FY18 GROUND TRANSPORT EQUIPMENT FACILITY, FORT HUACHUCA, AZ

SEE CONTINUATION PAGE FOR AMENDMENT 0003 SUMMARY OF CHANGES.

PLEASE BE ADVISED THAT DOD SAFE DROP-OFF CODES EXPIRE IN 14 DAYS. ALL BIDDERS MUST REQUEST A

NEW CODE IF THEIR EXISTING CODE WILL EXPIRE BEFORE BID SUBMITTAL.

GROUND TRANSPORTATION EQUIPMENT BUILDING (GTEB) FORT HUACHUCA

AMENDMENT 0003 SUMMARY OF CHANGES

SPECIFICATIONS:

1. Revise Table of Contents Page 5 adding an Appendices Section and

a. Appendix 1. Hazardous Material Reports for Existing Motor Pool buildings to be demolished. NOTE: Contractor to bid based on info in that attached test results. If no results are available for a building, for bidding purposes, contractor shall assume no HAZMAT.

HOWEVER, contractor is responsible for performing HAZMAT testing on all buildings to be demo’ed. Any discrepancies resulting from contractor testing will be addressed via Changes clause.

b. Appendix 2. Fort Huachuca Fire Department requirements. Note; these items are required for work under this contract.

2. Revise Section 01 57 20 Paragraph 3.18 regarding UXO monitors.

3. Revise CD-101 with FH Fire Department Requirements note.

4. Revise Drawing CD-104 adding Notes 5-9.

5. Revise Drawing C-510 showing fence fabric at 8 feet high.

6. Revise Drawing A-102 and add Drawing A-102a.

7. Revise Drawing A-620; A-640 and A-641.

8. Revise Drawing M-602 clarifying "Option" requirements.

9. Revise E-601 Note for wire size form DP-1 to XP-1.

10. Revise Drawing FA-601 adding Note 6 on Fire Alarm Panel requirement (Monaco).

11. Revise a series of Electrical drawings; E-001; EP-102; EG-102; E-401; E-402; E-504; 101;

T-102; T-103; T-501; T-502; T-601.

12. SF-1442. Change Bid due date from 30 October 2020 to 6 November 2020 12PM PST.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NUMBER 2. TYPE OF SOLICITATION

SEALED BID (IFB)

NEGOTIATED (RFP)

3. DATE ISSUED PAGE OF PAGES

IMPORTANT - The "offer" section on the reverse must be fully completed by the offeror.

4. CONTRACT NUMBER 5. REQUISITION/PURCHASE REQUEST NUMBER 6. PROJECT NUMBER

7. ISSUED BY CODE 8. ADDRESS OFFER TO

9. FOR INFORMATION CALL

A. NAME B. TELEPHONE NUMBER (Include area code) (NO COLLECT CALLS)

SOLICITATION

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying number, date):

11. The Contractor shall begin performance within calendar days and complete it within calendar days after receiving award, notice to proceed. This performance period is mandatory, negotiable. (See .)

12A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

12B. CALENDAR DAYS

YES NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and copies to perform the work required are due at the place specified in Item 8 by (hour) local time (date). If this is a sealed bid solicitation, offers will be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror’s name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, is not required.

C. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.

NSN 7540-01-155-3212

Designed using Perform Pro, WHS/DIOR, Oct 96

1442-103 STANDARD FORM 1442 (REV. 4-85) (EG)

Prescribed by GSA - FAR (48 CFR) 53.236-1(d)

W912PL21B0002 X 18 SEP 2020 1 OF

USACE, Los Angeles District Contracting Division, West Region Branch 915 Wilshire Blvd Los Angeles, CA 90017

DoD Secure Access File Exchange (DoD Safe) at https://safe.apps.mil/

See Section 00 22 13, Special Instructions Pertaining to Submission of Electronic Bids

JIMMY L. BARTON 213.452.3251

FY18 GROUND TRANSPORT EQUIPMENT FACILITY, FORT HUACHUCA, AZ

This a fully designed project (Design Bid Build). Construct a Ground Transport Equipment Building Complex. Project includes a vehicle maintenance shop (ground transport equipment building), organizational storage building, organizational vehicle parking, vehicle wash platform, vehicle loading dock, petroleum, oils and lubricants (POL) storage, and other hazardous waste/material storage. The vehicle maintenance facility will include mechanical and electrical rooms, telecommunications, HVAC, fire detection and sprinkler suppression systems, building information systems, intrusion detection system (IDS) installation, integrated energy, monitoring and control system (EMCS) connected to the base monitoring systems, and the installation of fire alarm systems. Supporting facilities will include connection to all utilities, lighting, paving, parking areas, sidewalks, curbs and gutters, rainwater harvesting systems, and signage. Heating and air conditioning will be provided by self-contained systems.

The estimated magnitude of project is between $25,000,000 and $100,000,000. This solicitation is UNRESTRICTED and all responsive and responsible parties are invited to submit a bid. The North American Industry Classification System (NAICS) code is 236220 Commercial and Institutional Building

BIDDERS PLEASE NOTE: “This project may be delayed, canceled or revised at any time prior to award.”

10 * 00 73 00

X X *Section 00 73 00

X 10

0 12PM

06 NOV 2020

X

OFFER (Must be fully completed by offeror)

STANDARD FORM 1442 BACK (REV. 4-85)

14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code) 15. TELEPHONE NUMBER (Include area code)

16. REMITTANCE ADDRESS (Include only if different than Item 14)

CODE FACILITY CODE

17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government in writing within calendar days after the date offers are due. (Insert any number equal or greater than the minimum requirement stated in 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGEMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation - give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER (Type or print) 20B. SIGNATURE 20C. OFFER DATE

AWARD (To be completed by Government)

21. ITEMS ACCEPTED

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24.SUBMIT INVOICES TO ADDRESS SHOWN IN

(4 copies unless otherwise specified)

ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) ( ) 41 U.S.C. 253(c) ( )

26. ADMINISTERED BY 27. PAYMENT WILL BE MADE BYCODE

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

28. NEGOTIATED AGREEMENT (Contractor is required to sign this document and return copies to the issuing office.) Contractor agrees to furnish and deliver all items or perform all work requirements identified on this form and any continuation sheets for the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and

(c) the clauses, representations, certifications, and specifications incorporated by reference in or attached to this contract.

29. AWARD. (Contractor is not required to sign this document.) Your offer on this solicitation is hereby accepted as to the items listed. This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award. No further contractual document is necessary.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED TO SIGN

(Type or print)

30B. SIGNATURE 30C. DATE

31A. NAME OF CONTRACTING OFFICER (Type or print)

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

DUNS NO.: TAX ID NO.:

CAGE CODE NO.:

( ) - ; FAX ( ) -

USACE, Finance Center

ATTN: CEFCO-AO-D

5722 Integrity Drive Millington, TN 38054-5005

FY18 Ground Transport Facility W912PL21B0002 Ft Huachuca, AZ

TABLE OF CONTENTS - 5

DIVISION 27 - COMMUNICATIONS

27 05 14.00 10 CABLE TELEVISION PREMISES DISTRIBUTION SYSTEM

27 05 28.36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

27 13 23 COMMUNICATIONS OPTICAL BACKBONE CABLING

27 51 16 RADIO AND PUBLIC ADDRESS SYSTEMS

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING

28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS)

28 31 49 CARBON MONOXIDE DETECTORS

28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM

DIVISION 31 - EARTHWORK

31 00 00 EARTHWORK

31 11 00 CLEARING AND GRUBBING

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 11 20 SUBBASES FOR FLEXIBLE PAVING

32 11 23 AGGREGATE BASE COURSES

32 12 10 BITUMINOUS TACK COAT

32 12 17 HOT MIX BITUMINOUS PAVEMENT

32 12 18 RESIN MODIFIED PAVEMENT SURFACING MATERIAL

32 16 13 CONCRETE SIDEWALKS AND CURBS AND GUTTERS

32 17 23 PAVEMENT MARKINGS

32 31 13.53 HIGH-SECURITY CHAIN LINK FENCES AND GATES

DIVISION 33 - UTILITIES

33 08 55 COMMISSIONING OF FUEL FACILITY SYSTEMS

33 11 00 WATER UTILITY DISTRIBUTION PIPING

33 30 00 SANITARY SEWERS

33 40 00 STORM DRAINAGE UTILITIES

33 51 13 NATURAL-GAS METERING

33 51 15 NATURAL-GAS DISTRIBUTION

33 56 10 FACTORY-FABRICATED FUEL STORAGE TANKS

33 58 00 LEAK DETECTION FOR FUELING SYSTEMS

33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION

33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

DIVISION 41 - MATERIAL PROCESSING AND HANDLING EQUIPMENT

41 22 13.13 BRIDGE CRANES

-- End of Table of Contents --

APPENDICES

APPENDIX 1

APPENDIX 2

HAZARDOUS MATERIAL REPORTS

FORT HUACHUCA FIRE DEPARTMENT REQUIRMENTS

AMENDMENT 3

Client Job: 1-1580911 PO Number:68056

JobNumber: 201300606

Routing Number: -

# Samples: 1

PLMn

PLM The "New" Method; see below

Client:

Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample

Method and Analysis Information:

Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.

Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."

The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40CFT Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US

EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are <= 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0- 5%. This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or

"negative". For this reason, Fiberquant refers to results where asbestos was detected but <= 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.

Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope

(TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.

The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that analysts can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the

Method: EPA 600/R-93/116Rec: 1/17/2013

Report Date: 1/23/2013 Date Analyzed: 1/23/2013

Fiberquant Internal SOP:

EMCOR GOVERNMENT SVCS

CLARKSTON RD BLDG 30033

FT HUACHUCA, AZ

Office Phone: (520) 533-5906

FAX: (520) 533-3699

85613-0000

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 1 of 3

PLM Analysis Summary: Job Number: 201300606 1-1580911 estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab #101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical

Services.

Job Analysis Notes:

Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.

Sample Number Lab Number Apparent Sample Type * Positive Layer Yes or No

Layer Color Apparent Layer Type * Asbestos Results

Roofing2013-00606- 168056-01 Positive Layer? YesSample # no asbestos detectedroofing roll/shingleblackLayer # 1 no asbestos detectedroofing roll/shingleblackLayer # 2

20-30% chrysotile asbestosroofing roll/shingleblackLayer # 3

20-30% chrysotile asbestosroofing roll/shingleblackLayer # 4

20-30% chrysotile asbestosroofing roll/shingleblackLayer # 5 no asbestos detectedroofing roll/shingleblackLayer # 6 no asbestos detectedroofing roll/shingleblackLayer # 7 no asbestos detectedroofing roll/shingleblackLayer # 8

30-40% chrysotile asbestosroof plyblackLayer # 9 no asbestos detectedroof plyblackLayer # 10

* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the apparent type of material may not be the actual type of material.

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 2 of 3

PLM Analysis Details Job Number: 201300606 1-1580911

2013-00606- 168056-01 Lab Number Sample Sampled:

DMSAnalyzed By 1/23/2013

Homogeneous

Roofing

No

Fibrous SolidOKAn?

10# Layers YesPos Layer?

Apparent Smp Type cellulose fiber chrysotile asbestosFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. Note: there appears to be more than one sample layer sequence in the bag (e.g., samples from more than one location); therefore, the reported layer sequence has been estimated/composited.

Fibers

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations cellulose fiber chrysotile asbestos 1.556 1.5491.550 vb/g pb/r

W F N N H + U

W A N N L + P

Non-Fibrous Components (in approx. decreasing order): bitumen, rock, 30# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 11 30-40% n.d. - - - -roofing roll/shingle black 1

2 11 30-40% n.d. - - - -roofing roll/shingle black 1

3 11 2-5% 20-30% - - - -roofing roll/shingle black 1

4 11 2-5% 20-30% - - - -roofing roll/shingle black 1

5 11 2-5% 20-30% - - - -roofing roll/shingle black 1

6 11 30-40% n.d. - - - -roofing roll/shingle black 1

7 11 30-40% n.d. - - - -roofing roll/shingle black 1

8 11 30-40% n.d. - - - -roofing roll/shingle black 1

9 6 5-10% 30-40% - - - -roof ply black 1

10 6 60-70% n.d. - - - -roof ply black 1

100Total % 20-30% 10-20% - - - -Overall %

Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;

D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow; vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.

RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber

23-Jan-13Analyst: DAVID M. SCHALLER

Larry S. Pierce, Approved Accreditation Signatory

Printed:

23-Jan-13Original Print Date:

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 3 of 3

Client Job: 1-1610512 PO Number: 68056

JobNumber: 201301115

Routing Number: -

# Samples: 1

PLMn

PLM The "New" Method; see below

Client:

Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample

Method and Analysis Information:

Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.

Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."

The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40CFT Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US

EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are <= 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0- 5%. This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or

"negative". For this reason, Fiberquant refers to results where asbestos was detected but <= 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.

Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope (TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.

The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that

Method: EPA 600/R-93/116Rec: 1/31/2013

Report Date: 2/5/2013 Date Analyzed: 2/5/2013

Fiberquant Internal SOP:

EMCOR GOVERNMENT SVCS

CLARKSTON RD BLDG 30033

FT HUACHUCA, AZ

Office Phone: (520) 533-5906

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

PLM Analysis Summary: Job Number: 201301115 1-1610512 analysts can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab

#101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical Services.

Job Analysis Notes:

Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.

Sample Number Lab Number Apparent Sample Type * Positive Layer Yes or No

Layer Color Apparent Layer Type * Asbestos Results

Wall System2013-01115- 168056-01 Positive Layer? NoSample # no asbestos detectedpaintblackLayer # 1 no asbestos detectedpaper/cardboardtanLayer # 2 no asbestos detecteddrywall corewhiteLayer # 3

* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

PLM Analysis Details Job Number: 201301115 1-1610512

2013-01115- 168056-01 Lab Number Sample Sampled:

MACAnalyzed By 2/5/2013

Homogeneous

Wall System

No

Fibrous SolidOKAn?

3# Layers NoPos Layer?

Apparent Smp Type cellulose fiber Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. Note: no texture layer observed.

Fibers

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations cellulose fiber

W F N N H + U

Non-Fibrous Components (in approx. decreasing order): powder, polymer, 8# Sub-Samples

Condition: acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 2 n.d. - - - - -paint black 1

2 4 90-100% - - - - -paper/cardboard tan 2

3 94 <=1% - - - - -drywall core white 3

100Total % 2-5% - - - - -Overall %

Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable

Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various

Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;

D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper

Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High

Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining

Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow;

vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.

RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber

05-Feb-13Analyst: MICHAEL A. COOK

Larry S. Pierce, Approved Accreditation Signatory

05-Feb-13Original Print Date:

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Client Job: 1-1580912 PO Number:68057

JobNumber: 201300604

Routing Number: -

# Samples: 1

PLMn

PLM The "New" Method; see below

Client:

Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample

Method and Analysis Information:

Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.

Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."

The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40CFT Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US

EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are <= 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0- 5%. This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or

"negative". For this reason, Fiberquant refers to results where asbestos was detected but <= 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.

Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope

(TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.

The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that analysts can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the

Method: EPA 600/R-93/116Rec: 1/17/2013

Report Date: 1/23/2013 Date Analyzed: 1/23/2013

Fiberquant Internal SOP:

EMCOR GOVERNMENT SVCS

CLARKSTON RD BLDG 30033

FT HUACHUCA, AZ

Office Phone: (520) 533-5906

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

PLM Analysis Summary: Job Number: 201300604 1-1580912 estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab #101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical

Services.

Job Analysis Notes:

Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.

Sample Number Lab Number Apparent Sample Type * Positive Layer Yes or No

Layer Color Apparent Layer Type * Asbestos Results

Roofing2013-00604- 168057-01 Positive Layer? YesSample # no asbestos detectedroofing roll/shingleblackLayer # 1 no asbestos detectedroofing roll/shingleblackLayer # 2

20-30% chrysotile asbestosroofing roll/shingleblackLayer # 3

20-30% chrysotile asbestosroofing roll/shingleblackLayer # 4 no asbestos detectedroofing roll/shingleblackLayer # 5 no asbestos detectedroof plyblackLayer # 6 no asbestos detectedroof plyblackLayer # 7

* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

PLM Analysis Details Job Number: 201300604 1-1580912

2013-00604- 168057-01 Lab Number Sample Sampled:

DMSAnalyzed By 1/23/2013

Homogeneous

Roofing

No

Fibrous SolidOKAn?

7# Layers YesPos Layer?

Apparent Smp Type cellulose fiber synthetic fiber (extr chrysotile asbestosFiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. Note: there appears to be more than one sample layer sequence in the bag (e.g., samples from more than one location); therefore, the reported layer sequence has been estimated/composited.

Fibers

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations cellulose fiber synthetic fiber (extruded) chrysotile asbestos 1.556 1.5491.550 vb/g pb/r

W F N N H + U

W E N N H + P

W A N N L + P

Non-Fibrous Components (in approx. decreasing order): bitumen, rock, 21# Sub-Samples

Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 17 30-40% 2-5% n.d. - - -roofing roll/shingle black 1

2 17 30-40% n.d. n.d. - - -roofing roll/shingle black 1

3 17 5-10% n.d. 20-30% - - -roofing roll/shingle black 1

4 17 5-10% n.d. 20-30% - - -roofing roll/shingle black 1

5 17 10-20% n.d. n.d. - - -roofing roll/shingle black 1

6 8 40-50% n.d. n.d. - - -roof ply black 1

7 7 60-70% n.d. n.d. - - -roof ply black 1

100Total % 20-30% <=1% 10-20% - - -Overall %

Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable

Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various

Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;

D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper

Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High

Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining

Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow;

vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.

RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber

23-Jan-13Analyst: DAVID M. SCHALLER

Larry S. Pierce, Approved Accreditation Signatory

23-Jan-13Original Print Date:

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Client Job: 1-1610514 PO Number: 68057

JobNumber: 201301117

Routing Number: -

# Samples: 4

PLMn

PLM The "New" Method; see below

Client:

Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample

Method and Analysis Information:

Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.

Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."

The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual.