| ETA-10-0109 Hilti Firestop Foam CFS-F-FX[1].pdf |
| MEMBER OF EOTA |
| I LEGAL BASIS AND GENERAL CONDITIONS |
| II SPECIFIC CONDITIONS OF THE EUROPEAN TECHNICAL APPROVAL |
| 1 Definition of product and intended use |
| 1.1 Definition of the construction product |
| 1.1.1 Hilti Firestop Foam CFS-F FX |
| 1.1.2 Additional components |
| 1.2 Intended use and use category |
| 1.2.1 Intended use |
| 1.2.2 Use category |
| 2 Characteristics of products and methods of verification |
| 2.1 Reaction to fire |
| 2.2 Resistance to fire |
| 2.3 Air permeability, and permeability regarding some other gases |
| 2.4 Water permeability |
| 2.5 Dangerous substances |
| 2.6 Mechanical resistance and stability |
| 2.7 Resistance to impact/movement |
| 2.8 Adhesion |
| 2.9 Airborne sound insulation |
| 2.10 Thermal insulation |
| 2.11 Water vapour permeability |
| 2.12 Durability and serviceability |
| 2.12.1 Durability |
| 2.12.2 Serviceability |
| 3 Evaluation and attestation of conformity and CE marking |
| 3.1 System of attestation of conformity |
| 3.2 Responsibilities |
| 3.2.1 Tasks of the manufacturer |
| 3.2.1.1 Factory production control |
| 3.2.1.2 Other tasks of manufacturer |
3.2.2 Tasks of approved bodies
| 3.3 CE-marking |
| 3.4 Other marking and/or information |
| 4 Assumptions under which the fitness of the product for the intended use was favourably assessed |
| 4.1 Manufacturing |
| 4.2 Installation |
| 4.2.1 General |
| 4.2.2 Cable seals |
| 4.2.3 Pipe seals |
| 4.2.4 Design |
| 4.2.5 Tool and equipment for application |
| 4.2.6 Applications including Hilti Firestop Bandage CFS-B |
| 5 Indications to the manufacturer and supplier |
| 5.1 Packaging, transport and storage |
| 5.2 Use, maintenance and repair |
| AMEND0003_C5_TRAINING_TECH_SPECS_w_red_lines.pdf |
| COVER |
| INDEX OF SECTION |
| PROJECT TABLE OF CONTENTS |
| PACK_C_e_D_22 07 19.00 40_with_red_lines |
| 22 07 19.00 40 - PLUMBING PIPING INSULATION |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.3 SYSTEM DESCRIPTION |
| 1.4 PERFORMANCE REQUIREMENTS |
| 1.5 SUBMITTALS |
| PART 2 PRODUCTS |
| 2.1 MATERIALS |
| 2.1.1 Adhesives |
| 2.1.1.1 Cloth Adhesives |
| 2.1.1.2 Vapor-Barrier Material Adhesives |
| 2.1.1.3 Cellular Elastomer Insulation Adhesive |
| 2.1.2 Coatings |
| 2.1.2.1 Outdoor Vapor-Barrier Finishing |
| 2.1.2.2 Indoor Vapor-Barrier Finishing |
| 2.1.2.3 Outdoor and Indoor Nonvapor-Barrier Finishing |
| 2.1.2.4 Cellular-Elastomer Insulation Coating |
| 2.1.2.4 Coating Color |
| 2.1.3 Insulating Cement |
| 2.1.3.1 General Purpose Insulating Cement |
| 2.1.3.2 Finishing Insulating Cement |
| 2.1.4 Calking |
| 2.1.5 Corner Angles |
| 2.1.6 Insulation Materials |
| 2.1.6.1 Mineral Fiber |
| 2.1.6.2 Pipe BarrelPhenolic Foam Pipe Insulation |
| 2.1.6.3 Pipe Fittings |
| 2.1.6.4 Flexible Blankets |
| 2.1.6.5 Cellular Elastomer |
| 2.1.6.5 Cellular Glass |
| 2.1.6.7 Calcium Silicate |
| 2.1.7 Jacketing |
| 2.1.7.1 Aluminum Jackets |
| 2.1.7.2 Glass Cloth Jackets |
| 2.1.7.3 PVC Jackets |
| 2.1.7.4 3-Ply Laminate |
2.1.8 Tape
| 2.2 PIPING SYSTEMS |
| 2.2.1 Dual-Temperature Hot- and Chilled- Water Piping |
| 2.2.1 Domestic Hot-Water, Steam, and CondensateHot Water-Return Piping |
| 2.2.2 Domestic Cold-Water, Condensate-Drain, and Roof Drain Piping |
| 2.2.4 Refrigerant Suction Piping |
| 2.2.5 Cooling-Tower Circulating Water Piping |
| 2.2.6 Steam and Condensate Piping, 350 psig |
| 2.2.7 Hot Water Heating Converter |
| 2.2.8 Chilled-Water and Dual-Temperature Pumps |
| 2.2.9 Low-Pressure Steam and Condensate, Weather-Exposed |
| 2.2.10 Steam & Condensate, Weather-Exposed, 861 kilopascal |
| 2.2.11 Steam & Condensate, Weather-Exposed, 2.4 Megapascal |
| PART 3 EXECUTION |
| 3.1 INSTALLATION OF INSULATION SYSTEMS |
| 3.2 SYSTEM TYPES |
| 3.2.1 Type T-1, Mineral Fiber with Vapor-Barrier Jacket |
| 3.2.2 Type T-2, Mineral Fiber with Glass Cloth Jacket |
| 3.2.3 Type T-3, Cellular Elastomer |
| 3.2.3 Type T-4, Cellular Glass with Vapor-Barrier Jacket |
| 3.2.5 Type T-5, Calcium Silicate with Glass Cloth Jacket Piping |
| 3.2.4 Type T-6, Mineral Fiber with Aluminum Jacket |
| 3.2.7 Type T-7, Calcium Silicate with Glass Cloth Jacket Surfaces |
| 3.2.8 Type T-9, Cellular Elastomer |
| 3.2.5 Type T-10, Mineral-Fiber Fill |
| 3.2.10 Type T-17, Calcium Silicate Weatherproof Jacket |
| 3.2.6 Phenolic Foam |
| 3.2.6.1 General Installation Requirements: |
| 3.2.6.2 Insulation Installation on Straight Piping |
| 3.2.6.3 Insulation Installation on Pipe Flanges |
| 3.2.6.4 Insulation Installation on Pipe Fittings and Elbows |
| 3.2.6.5 Insulation Installation on Valves and Pipe Specialties |
3.3 ACCEPTANCE
| PACK_C_e_D_23 07 00.00 42_with_red_lines |
| 23 07 00.00 42 - MECHANICAL INSULATION |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.3 SYSTEM DESCRIPTION |
| 1.3.1 Packaging and Labeling |
| 1.3.2 Surface Burning Characteristics |
| 1.4 SUBMITTALS |
| 1.4.1 LEED Requirements |
1.4 IDENTIFICATION OF NEW ASBESTOS-FREE INSULATION
| PART 2 PRODUCTS |
| 2.1 SOURCE MANUFACTURERS |
| 2.1.1 Mechanical Insulation |
| 2.2 PIPING INSULATION AND JACKET |
| 2.2.1 Fibrous Glass Preformed Insulation |
| 2.2.2 Phenolic Foam Pipe Insulation |
| 2.2.3 Flexible Cellular Preformed Pipe Insulation |
| 2.2.4 Cellular Glass |
| 2.2.5 Piping Insulation Jacket |
| 2.2.6 Aluminum Jacket |
| 2.1.7 PVC Jacket |
| 2.3 DUCT INSULATION AND JACKET |
| 2.3.1 Blanket Type Duct Insulation |
| 2.3.2 Rigid Type Duct Insulation |
| 2.3.3 Duct Insulation Jacket |
| 2.4 EQUIPMENT INSULATION AND JACKET |
| 2.4.1 Mineral Fiber Block and Board Insulation |
| 2.4.2 Calcium Silicate Block and Board Insulation |
| 2.4.3 Phenolic Block and Board Insulation |
| 2.4.4 Equipment Insulation Jacket |
| 2.5 BOILER STACK INSULATION AND JACKET For CEP Building Only |
| 2.5.1 Mineral Fiber Preformed Pipe Insulation |
| 2.5.2 Calcium Silicate Preformed Pipe Insulation |
| 2.5.3 Aluminum Jacket |
| PART 3 EXECUTION |
| 3.1 INSTALLATION OF MECHANICAL INSULATION |
| 3.2 PIPING INSULATION |
| 3.2.1 Insulation for Water Piping |
| 3.2.1.1 Heating Hot Water piping, and Hot and Cold Domestic Water Piping |
| 3.2.1.2 Cold Drain Piping |
| 3.2.1.3 Roof Drain Piping |
| 3.2.1.2 Water Piping With Electric-Resistance Heater Cable |
| 3.2.2 Insulation for Chilled Water Piping and Chilled-Hot Water Piping |
| 3.2.2.1 Cellular Glass |
| 3.2.2.2 Phenolic Foam |
| 3.2.2.3 Elastomeric Cellular |
| 3.2.3 Insulation for Refrigerant Suction and Condensate Drain Piping |
| 3.2.4 Insulation for Steam Piping and Condensate Piping For CEP |
| 3.2.5 Piping Insulation Covering |
| 3.2.5 Piping Insulation Covering Exposed to the Weather |
| 3.3 DUCT INSULATION |
| 3.3.1 Blanket Duct Insulation |
| 3.3.2 Rigid Duct Insulation |
| 3.3.3 Vapor Barrier |
| 3.4 WEATHERPROOF DUCT INSULATION |
| 3.5 EQUIPMENT INSULATION |
| 3.5.1 Pumps |
| 3.5.2 Expansion Tanks, Receivers, Converters, and Storage Tanks |
| 3.6 BOILER STACK INSULATION AND JACKET |
| 3.7 FIELD INSPECTIONS |
| C5_TRAINING_23 20 23.00 42_with_red_lines |
| 23 20 23.00 42 - CHILLED, CONDENSER, OR DUAL SERVICE WATER PIPING |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 Related Requirements |
| 1.3 GENERAL REQUIREMENTS |
| 1.3.1 Description of Work |
| 1.3.2 Associated Work |
| 1.3.3 System Design Temperatures, Pressures, and Classes |
| 1.4 SUBMITTALS |
| 1.5 QUALITY ASSURANCE |
| 1.5.1 Defective Welds |
| 1.5.2 Previous Welder Qualifications |
| 1.5.3 Welding Procedure |
| 1.5.4 Performance Qualification Record |
| 1.5.5 List of Welders' Names and Symbols |
| 1.5.6 Backflow Preventer Certificate |
| 1.5.7 Posted Operating Instructions |
| 1.6 SPECIMENS, CORROSION PREVENTION OF FERROUS METALS |
| 1.7 SAFETY PRECAUTIONS |
| 1.7.1 Rotating Equipment Safety |
| 1.7.2 Welding and Cutting Safety |
| PART 2 PRODUCTS |
| 2.1 SOURCE MANUFACTURERS |
| 2.1.1 Water Piping, Fittings, and Accessories |
| 2.1.2 Valves |
| 2.1.3 Miscellaneous Components |
| 2.1.4 Pumps |
| 2.1.5 Tanks |
| 2.1.6 Expansion Joints |
| 2.1.7 Backflow Preventers |
| 2.2 WATER PIPING, FITTINGS, AND ACCESSORIES |
| 2.2.1 Chilled Water Piping |
| 2.2.2 Condenser Water Piping |
| 2.2.3 Hot and Cold Water Dual Service Piping |
| 2.2.2 Fittings and Flanges for Steel Piping |
| 2.2.2.1 Sizes 3 to 50 Millimeters |
| 2.2.2.2 Sizes 65 Millimeters and Above |
| 2.2.3 Fittings for Copper Tubing |
| 2.2.4 Unions |
| 2.2.4.1 Unions Threaded for Steel Pipe |
| 2.2.4.2 Unions for Copper Tubing |
| 2.2.4.3 Dielectric Union |
| 2.2.5 End Connections |
| 2.2.5.1 Steel Piping |
| 2.2.5.2 Joints for Copper Tubing |
| 2.2.6 Valves and Related Equipment |
| 2.2.6.1 Gate, Valves |
| 2.2.6.2 Globe and Angle Valves |
| 2.2.6.3 Check Valves |
| 2.2.8.4 Water Temperature Mixing Valves |
| 2.2.8.5 Water Pressure-Reducing Valves |
| 2.2.6.4 Plug Valves |
| 2.2.6.5 Ball Valves |
| 2.2.6.6 Drain Valves |
| 2.2.6.7 Air Vent Valves |
| 2.2.8.10 Automatic Flow Control Valves |
| 2.2.6.8 Butterfly Valves |
| 2.2.8.12 Solenoid Valves |
| 2.2.8.13 Automatic Water Regulating Valves |
| 2.2.8.14 Float Valves |
| 2.2.6.9 Safety Relief Valves |
| 2.2.6.10 Balancing Valves |
| 2.2.7 Miscellaneous Components for Piping System |
| 2.2.7.1 Strainers |
| 2.2.7.2 Flexible Hose |
| 2.2.7.3 Flow Measuring Equipment |
| 2.2.7.4 Pipe Hangers and Supports |
| 2.2.7.5 Pipe Guides |
| 2.2.7.6 Pipe Sleeves |
| 2.2.7.7 Condensate Drains |
| 2.2.9.8 Cooling Coil Drain Pans |
| 2.2.8 Pumps |
| 2.2.8.1 Pump Motors |
| 2.2.8.2 Motor Starters |
| 2.2.9 Tanks |
| 2.2.9.1 Expansion Tank |
| 2.2.9.2 External Air Separation Tank |
| 2.2.10 Instrumentation |
| 2.2.10.1 Pressure and Vacuum Gages |
| 2.2.12.2 Tank Gages |
| 2.2.10.2 Indicating Thermometers |
| 2.2.12.4 Remote Reading Thermometers |
| 2.2.10.3 Pressure/Temperature Test Ports |
| 2.2.11 Expansion Joints |
| 2.2.11.1 Guided Slip Tube Expansion Joints |
| 2.2.11.2 Flexible Ball Expansion Joints |
| 2.2.13.3 Bellows Expansion Joints |
2.2.14 Backflow Preventers
| 2.3 WATER TREATMENT SYSTEMS |
| 2.3.1 Tanks |
| 2.3.2 Pumps |
| 2.3.3 Corporation Stop |
| 2.3.4 Pretreatment |
| 2.3.5 Chemicals |
| 2.3.6 Testing Equipment |
| 2.3.7 Timers |
| 2.3.8 Sequence of Operation |
| 2.3.8.1 Timers |
| 2.3.9 Piping |
| 2.3.10 Water Analysis |
| 2.3.1 Pipe Cleaning Chemical |
| 2.3.2 Pipe Cleaning Accessories |
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.1.1 Water Piping |
| 3.2 PIPING SYSTEMS |
| 3.2.1 Flanged Joints |
| 3.2.2 Threaded Joints |
| 3.2.3 Pipe Bends |
| 3.2.3.1 Copper Tubing |
| 3.2.4 Reducing Fittings |
| 3.2.5 Insulation |
| 3.2.6 Brazing and Soldering |
| 3.2.7 Dielectric Unions or Flanges |
| 3.2.8 Pipe Hangers and Supports |
| 3.2.9 Pipe Guides |
| 3.2.10 Flexible Connections |
| 3.2.11 Pipe Sleeves |
| 3.3 WATER PIPING |
| 3.3.1 Fabrication and Assembly of Piping and Components |
| 3.3.1.1 Insulation of Copper Tubing |
| 3.3.1.1 Strainers |
| 3.3.1.3 Shell and Tube Vessels and Clearance |
| 3.3.1.2 Piping, Chilled Water Coils |
| 3.3.1.3 Pumps |
| 3.3.1.4 Valves |
| 3.3.1.5 Air Vent Valves |
| 3.3.1.6 Orifice Flanges |
| 3.3.1.9 Automatic Flow Control Valve |
| 3.3.1.10 Automatic Water Regulating Valves |
| 3.3.1.7 Closed Expansion Tank |
| 3.3.1.8 Instrumentation |
| 3.4 MISCELLANEOUS DRAINS |
| 3.4.1 Condensate Drains |
| 3.4.2 Cooling Coil Drain Pans |
| 3.5 MISCELLANEOUS PIPING |
| 3.5.1 Make-up Water Piping |
| 3.5.2 Drain and Overflow Piping |
| 3.5.3 Water Bleedoff Piping |
| 3.5.4 Cooling Towers and Evaporative Condensers |
| 3.5 ELECTRICAL EQUIPMENT |
| 3.7 WATER CHEMICAL TREATMENT |
| 3.7.1 Supervision |
| 3.7.2 Equipment Placement and Mounting |
| 3.7.3 Operating Instruction |
| 3.7.4 Service |
| 3.7.5 Chemical Parameters |
| 3.6 CLEANING OF SYSTEMS |
| 3.6.1 Safety Procedure |
| 3.7 IDENTIFICATION OF PIPING AND PHYSICAL HAZARDS |
| 3.8 FIELD INSPECTIONS |
| 3.9 FIELD TESTS |
| 3.9.1 Water Piping |
| 3.10 STARTUP AND OPERATIONAL TESTS |
| 3.11 TESTING, ADJUSTING, AND BALANCING |
| C5_TRAINING_23 21 13.00 42_with_red_lines |
| 23 21 13.00 42 - LOW TEMPERATURE WATER LTW HEATING SYSTEM |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.3 RELATED REQUIREMENTS |
| 1.4 SYSTEM DESCRIPTION |
| 1.4.1 Hot Water Heating System |
| 1.5 SUBMITTALS |
| 1.6 QUALITY ASSURANCE |
| 1.6.1 Standard Commercial Product for Terminal Units |
| 1.6.2 Welding |
| 1.6.2.1 Welding Procedures |
| 1.6.2.2 Welder's Qualifications |
| 1.6.2.3 Identification of Welder's Work |
| 1.6.2.4 Previous Qualifications |
| 1.6.3 Brazing and Soldering |
| 1.6.3.1 Brazing Procedure |
| 1.6.3.2 Soldering, Soldering Preparation, and Procedures for Joints |
1.5.4 Backflow Preventer Certification
| 1.7 SAFETY STANDARDS |
| 1.7.1 Welding |
| 1.7.2 Guards |
| PART 2 PRODUCTS |
| 2.1 SOURCE MANUFACTURERS |
| 2.1.1 Pipe and Fittings |
| 2.1.2 Valves |
| 2.1.3 Piping Systems Equipment |
| 2.1.4 Terminal Equipment |
| 2.2 PIPE AND FITTINGS |
| 2.2.1 Hot Water Heating Pipe Supply and Return |
| 2.2.2 Fittings |
| 2.2.2.1 Steel or Malleable Iron Pipe |
| 2.2.2.2 Steel, Cast Iron, or Bronze |
| 2.2.2.3 Fittings for Copper Tubing |
| 2.2.3 Mechanical Pipe Coupling System |
| 2.2.3.1 Groove and Check Valves |
| 2.2.3.2 Butterfly Valves |
| 2.2.3.3 Strainers |
| 2.2.4 Unions |
| 2.2.4.1 Steel Pipe |
| 2.2.4.2 Copper Tubing |
| 2.2.4.3 Dielectric Union |
| 2.2.5 Flanges |
| 2.2.5.1 Steel Flanges |
| 2.2.5.2 Cast Iron Screwed Flanges |
| 2.2.5.3 Bronze Screwed Flanges |
| 2.2.6 Drains and Overflows |
| 2.2.6.1 Steel Pipe |
| 2.2.6.2 Copper Tubing |
| 2.2.6.3 PVC Pipe |
| 2.2.7 Valves |
| 2.2.7.1 Gate Valves |
| 2.2.7.2 Globe and Angle Valves |
| 2.2.7.3 Check Valves |
| 2.2.7.4 Temperature Regulating Valves |
| 2.2.7.5 Water Pressure-Reducing Valves |
| 2.2.7.6 Plug Valves |
| 2.2.7.7 Ball Valves |
| 2.2.7.8 Radiator Valves |
| 2.2.7.9 Flow Control Valves |
| 2.2.7.9 Butterfly Valves |
| 2.2.7.10 Butterfly Valves 2 Millimeters and Smaller |
| 2.2.7.11 Relief Valves |
| 2.2.7.12 Valve Operating Mechanisms |
| 2.2.7.13 Balancing Valves |
| 2.2.8 End Connections |
| 2.2.8.1 Flexible Connectors |
| 2.2.8.2 Steel Piping |
| 2.2.8.3 Joints for Copper Tubing |
| 2.2.9 Expansion Joints |
| 2.2.9.1 Packless Type |
| 2.2.9.2 Guided Slip-Tube Type |
| 2.2.10 Instrumentation |
| 2.2.10.1 Pressure and Vacuum Gauges |
| 2.2.10.2 Indicating Thermometers |
| 2.2.10.3 Pressure/Temperature Test Ports |
| 2.2.11 Miscellaneous Pipeline Components |
| 2.2.11.1 Air Vent |
| 2.2.11.2 Strainers |
| 2.2.11.3 Hangers and Supports |
| 2.2.11.4 Pipe Sleeves |
| 2.2.11.5 Escutcheon Plates |
| 2.3 CENTRAL MECHANICAL EQUIPMENT |
| 2.3.1 Boilers |
| 2.3.1 Hot Water Heat Exchangers |
| 2.3.3 Converters |
| 2.4 PIPING SYSTEM EQUIPMENT |
| 2.4.1 Pumps |
| 2.4.2 Expansion Tanks |
| 2.4.3 External Air Separation Tanks |
| 2.4.4 Backflow Preventers |
| 2.4.4 Flow Measuring Equipment |
| 2.5 TERMINAL UNITS |
| 2.5.1 Finned Tube Radiators |
| 2.5.2 Convectors |
| 2.5.2 Unit Heaters |
| 2.5.3 Heating and Ventilating Units |
| 2.6 ELECTRICAL EQUIPMENT |
| 2.7 CONTROLS |
| 2.8 INSULATION |
| 2.9 ASBESTOS PROHIBITION |
| PART 3 EXECUTION |
| 3.1 PREPARATION |
| 3.2 INSTALLATION |
| 3.2.1 Hangers and Supports |
| 3.2.2 Grading of Pipe Lines |
| 3.2.3 Pipe Sleeves |
| 3.2.4 Flashing for Buildings |
| 3.2.5 Unions and Flanges |
| 3.2.6 Connections for Future Equipment |
| 3.2.7 Changes in Pipe Size |
| 3.2.8 Cleaning of Pipe |
| 3.2.9 Valves |
| 3.2.9.1 Globe Valves |
| 3.2.9.2 Radiators Valves |
| 3.2.9.3 Relief Valves |
| 3.2.10 Pressure Gage |
| 3.2.11 Thermometers |
| 3.2.12 Strainers |
| 3.2.13 Pumps |
| 3.2.14 Equipment Foundations |
| 3.2.15 Equipment Installation |
| 3.2.16 Cleaning of Systems |
| 3.2.17 Painting of Piping and Equipment |
| 3.2.18 Identification of Piping |
| 3.3 FIELD QUALITY CONTROL |
| 3.3.1 Hydrostatic Test of Piping System |
| 3.3.2 Auxiliary Equipment and Accessory Tests |
| 3.3.2.1 Backflow Preventers |
| 3.4 TESTING, ADJUSTING, AND BALANCING |
| 3.4.1 Markings of Settings |
| 3.4.2 Sound Level Tests |
| C5_TRAINING_23 30 13.00 42_with_red_lines |
| 23 30 13.00 42 - DUCTWORK AND DUCTWORK ACCESSORIES |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.3 RELATED REQUIREMENTS |
| 1.4 PRESSURE CLASSIFICATION |
| 1.5 SUBMITTALS |
| 1.6 QUALITY ASSURANCE |
| 1.6.1 Modification of References |
| PART 2 PRODUCTS |
| 2.1 SOURCE MANUFACTURERS |
| 2.1.1 Metal Ducts |
| 2.1.2 Sound Attenuators |
| 2.1.2 Flexible Ducts |
| 2.1.3 Diffusers, Registers, and Grilles |
| 2.1.4 Access Doors |
| 2.1.5 Dampers and Louvers |
| 2.1.6 Fire Dampers |
| 2.1.7 Sealing Materials |
| 2.1.8 Fire-Stopping Materials |
| 2.1.9 Accessory Hardware |
| 2.2 Ductwork |
| 2.2.1 Steel Ducts |
| 2.2.2 Aluminum Ducts |
| 2.2.3 Copper Sheets |
| 2.2.4 Corrosion Resisting Stainless Steel Sheets |
| 2.2.5 Duct-Liner Adhesives |
| 2.2.6 Duct Sheet Metal Thickness |
| 2.3 DUCTS OF PRESSURE CLASSES |
| 2.3.1 Construction |
| 2.3.2 Joints |
| 2.3.3 Fittings |
| 2.3.3.1 Test Holes |
| 2.3.3.2 Round Elbows |
| 2.3.4 Round and Oval Ducts |
| 2.3.4.1 Round Duct Fittings Thickness |
| 2.3.4.2 Oval Fitting Construction |
| 2.3.4.3 Sealing |
| 2.3.4.4 Small Diameter Elbows |
| 2.3.4.5 Large Diameter Elbows |
| 2.3.4.6 Die-stamped Elbows |
| 2.3.4.7 Gored Elbows |
| 2.3.4.8 Pleated Elbows |
| 2.3.4.9 Mitered Elbows |
| 2.3.4.10 Diverging Flow Fittings |
| 2.3.4.11 Entrances |
| 2.3.5 Round Ducts |
| 2.3.5.1 Duct Metal Thickness |
| 2.3.5.2 Single-Rib Spiral Duct |
| 2.3.6 Oval Duct |
| 2.3.6.1 Duct Metal Thickness |
| 2.3.6.2 Reinforcement |
| 2.3.7 Joint Sealing of Round and Flat Oval Ductwork |
| 2.3.7.1 Round Supply Joint Construction Diameters less than 900 mm |
| 2.3.7.2 Round Supply Joint Construction diameters 900 mm and greater |
| 2.3.7.3 Oval Supply Joint Construction |
| 2.3.8 Rectangular Ducts |
| 2.3.9 Sound Attenuators Traps |
| 2.3.9.1 Net Noise Reduction Values |
| 2.3.9.2 Factory-Fabricated Sound Attenuators Traps |
| 2.3.9.3 Factory-Fabricated Sound-Attenuator Ducts |
| 2.3.10 Safety Relief Valve |
| 2.3.11 Air Valves |
| 2.4 DUCTS OF PRESSURE CLASSES 750 Pa GAGE OR LESS |
| 2.4.1 Curved Elbows |
| 2.4.2 Laps |
| 2.4.3 Fittings |
| 2.4.4 Round Duct |
| 2.4.5 Acoustical Attenuator Systems |
| 2.4.5.1 Acoustical Duct Lining |
| 2.4.5.2 Net Noise Reduction Values |
| 2.4.5.3 Preformed Duct Liner |
| 2.4.5.4 Factory-Fabricated Sound-Attenuator Ducts |
| 2.4.5.5 Sound Attenuators Traps |
| 2.5 FLEXIBLE DUCTS AND CONNECTORS |
| 2.5.1 Materials |
| 2.5.2 Insulation and Vapor Barrier |
| 2.5.3 Joints |
| 2.6 CASINGS AND PLENUMS |
| 2.7 DIFFUSERS, REGISTERS, AND GRILLES |
| 2.7.1 Material and Finishes |
| 2.7.2 Sound Pressure Level |
| 2.7.3 Throw |
| 2.7.4 Drop |
| 2.7.3 Ceiling Diffusers |
| 2.7.3.1 Circular, Square, and Rectangular Diffusers |
| 2.7.3.2 Perforated Plate Diffusers |
| 2.7.3.3 Linear Diffusers |
| 2.7.4 Registers |
| 2.7.5 Grilles |
| 2.8 TROFFERS |
| 2.8.1 Air Seal |
| 2.8.2 Interior Dampers or Deflectors Finish |
| 2.8.3 Lighting Fixture Characteristics |
| 2.8 DUCT SLEEVES, PREPARED OPENINGS, AND CLOSURE COLLARS |
| 2.8.1 Duct Sleeves |
| 2.8.2 Prepared Openings |
| 2.8.3 Packing |
| 2.8.4 Closure Collars |
| 2.9 DEFLECTORS |
| 2.10 ACCESS DOORS |
| 2.11 DAMPERS AND LOUVERS |
| 2.11.1 Backdraft Dampers Gravity Dampers or Shutters |
| 2.11.2 Manual Volume Dampers |
| 2.11.3 Manual Volume Dampers |
| 2.11.2 Manual Balancing Dampers |
| 2.11.2.1 Square or Rectangular Dampers |
| 2.11.2.2 Round Dampers |
| 2.11.3 Fire Dampers |
| 2.11.4 Automatic Smoke-Fire Dampers |
| 2.11.5 Automatic Smoke Dampers |
| 2.11.7 Dampers |
| 2.11.6 Automatic Dampers |
| 2.11.7 Louvers |
| 2.11.7.1 Bird Screens |
| 2.11.8.2 Louvered Penthouse |
| 2.12 TIE RODS |
| 2.13 SEALING MATERIALS |
| 2.13.1 Joint and Seam Sealants, General |
| 2.13.2 Tape Sealing System |
| 2.13.3 Joint and Seam Sealant |
| 2.13.4 Flanged Joint Mastics |
| 2.14 FIRE-STOPPING MATERIALS |
| 2.14.1 Fire Resistant Sealant |
| 2.15 DUCT HANGERS AND SUPPORTS |
| 2.15.1 Building Attachments |
| 2.15.2 Hangers |
| 2.15.3 Hangers Installed in Corrosive Atmosphere |
| 2.15.4 Duct Attachments |
| 2.16 ACCESSORIES |
| 2.16.1 Instrument Test Holes |
| 2.16.2 Splitter Damper Accessories |
| 2.16.3 Flexible Duct Clamps |
2.17 SEISMIC PROTECTION COMPONENTS FOR DUCTWORK
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.1.1 Ductwork |
| 3.1.1.1 Duct Construction |
| 3.1.1.2 Louvers |
| 3.1.1.3 Dampers |
| 3.1.1.4 Deflectors |
| 3.1.1.5 Fire Dampers |
| 3.1.1.6 Access Doors |
| 3.1.1.7 Duct Sleeves, Prepared Openings, and Closure Collars |
| 3.1.1.8 Packing |
| 3.1.2 Duct Hangers and Supports |
| 3.1.2.1 Flexible Ducts |
| 3.1.2.2 Flexible Connectors |
| 3.1.3 Inspection Plates and Test Holes |
| 3.1.4 Acoustical Duct Lining |
| 3.1.5 Flashing |
| 3.1.6 Cleaning of Ducts |
| 3.2 FIELD QUALITY CONTROL |
| 3.3 IDENTIFICATION INSTALLATION REQUIREMENTS |
| C5_TRAINING_23 34 16.00 42_with_red_lines |
| 23 34 16.00 42 - AIR HANDLING UNITS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 GENERAL REQUIREMENTS |
| 1.3 RELATED REQUIREMENTS |
| 1.4 SUBMITTALS |
| PART 2 PRODUCTS |
| 2.1 SOURCE MANUFACTURERS |
| 2.1.1 Air Handling Units |
| 2.2 FANS |
| 2.2.1 Centrifugal Fans |
| 2.2.2 Propeller Fans |
| 2.2.4 Power Roof and Wall Ventilators |
| 2.2.5 In-Line Tubular Centrifugal Fans |
| 2.2.6 Utility Sets |
| 2.2.7 Air Circulating Fans |
| 2.2.8 Air Curtains |
| 2.3 PACKAGED AIR HANDLING UNITS |
| 2.3.1 Casings |
| 2.3.2 Dampers |
| 2.3.3 Supply Fans |
| 2.3.3.1 Double Width Double Inlet DWDI, Housed Centrifugal Type |
| 2.3.3.2 Single Width Single Inlet SWSI, Plug Type Supply Fans |
| 2.3.4 Vibration Isolation |
| 2.3.5 Filter Sections |
| 2.3.5.1 Replaceable Air Filters |
| 2.3.5.2 Cleanable Air Filters |
| 2.3.5.2 Disposable Cartridge Air Filters |
| 2.3.5.3 Extended Media Pleated Air Filters |
| 2.3.5.5 High Efficiency Particulate HEPA Air Filters |
| 2.3.5.4 Filter Housing |
| 2.3.5.7 Odor Control |
| 2.3.6 Mixing Boxes |
| 2.3.7 Outside-Air Intake |
| 2.3.8 Heating and Cooling Sections |
| 2.3.8.1 Coils |
| 2.3.8.2 Heaters |
| 2.3.8.2 Eliminators |
| 2.3.8.3 Drip Pans |
| 2.3.9 Ultraviolet Disinfection System |
| 2.3.10 Energy Recovery Section |
| 2.3.9 Sprayed Coil Dehumidifiers |
| 2.3.10 Humidifiers |
| 2.3.10.1 Evaporative Pan |
| 2.3.10.2 Steam Grid |
| 2.3.10.3 Mechanical Water-Spray |
| 2.3.10.4 Atomizing or Wetted Element |
| 2.4 GRAVITY VENTILATORS |
| 2.5 FAN COIL UNITS |
| 2.5.1 Casing |
| 2.5.2 Fans |
| 2.5.3 Coils |
| 2.5.4 Drain Pans |
| 2.5.5 Motor |
| 2.5.6 Accessibility |
| 2.5.7 Controls |
| 2.6 ELECTROSTATIC IONIZING AIR FILTERS |
| 2.4 VARIABLE-AIR-VOLUME VAV TERMINAL UNITS |
| 2.4.1 Casings |
| 2.4.2 Insulation |
| 2.4.3 Controls |
| 2.4.4 Air-Volume Regulators |
| 2.4.5 Air Diffusers |
| 2.4.6 Reheat Coils |
| 2.4.6.1 Water Coils |
| 2.7.6.2 Electric Coils |
| 2.5 SERIES FAN POWERED VARIABLE AIR VOLUME VAV TERMINAL UNITS |
| 2.6 ELECTRICAL |
| 2.6.1 Electrical Motors, Controllers, Contactors, and Disconnects |
| 2.6.2 Electrical Work |
| 2.8 ROOF CURBS |
| 2.7 FINISH COATING FOR AIR HANDLING UNIT CASINGS |
| 2.12 CORROSION PROTECTION FOR MARINE ENVIRONMENTS |
| 2.12.1 Polyelastomer or Vinyl Finish Coating |
| 2.12.1.1 Heat Exchanger Coil Including Evaporator Coil Surfaces |
| 2.12.1.2 Uninsulated Interior Surfaces and Exterior Surfaces |
| 2.12.1.3 Insulated Interior Surfaces |
| 2.12.2 Phenolic Finish |
| 2.12.2.1 Heat Exchanger Coil Including Evaporator Coil Surfaces |
| 2.12.2.2 Uninsulated Interior Surfaces and Exterior Surfaces |
| 2.12.2.3 Insulated Interior Surfaces |
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.2 FIELD QUALITY CONTROL |
| 3.2.1 Equipment |
| 3.2.1.1 Field Testing |
| 3.2.1.2 Field Acceptance Test Plans |
| 3.2.1.3 Equipment Field Acceptance Testing |
3.2.2 Testing and Balancing