About this file

Drawing, Sheet 4 of 4

View the file

Other files

File Type Posted
03_Drawing_Sheet_1_of_4.pdf PDF
04_Drawing_Sheet_2_of_4.pdf PDF
05_Drawing_Sheet_3_of_4.pdf PDF
01_Solicitation_W912PB19Q8013.pdf PDF
02_Attachment_I,_Specification_14Mar19.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TOWER

A2YF(L)2Y 6 x 2 x 0.8

NEW/NEU

A2YF(L)2Y 6 x 2 x 0.8

EXISTING/BESTAND

DATA SLEEVE

MUFFE, DATEN

P1.4 P1.1

P1.2

P1.3

P2.1 P2.2

P2.3 P2.4

P2.5 P2.6

P3.1 P3.2

P3.3

P3.4

P4.1 P4.2

P4.3 P4.4

P11.1 P11.2

P11.3

P11.4

P11.5

P11.6

MOVER 1

MOVER 2

MOVER 3

P5.4

P5.3

P5.2

P6.1 P6.2

P6.3 P6.4

V4

V3

V1

Z1

V2

BP1

P7.4

P7.3 P7.2

P7.1

P8.4 P8.3

P8.2 P8.1

P10.4 P10.3

P10.2 P10.1

P9.4

P9.3

P9.2 P9.1

Z3

V11

V12

V10

V9

V8

V6

BP2

V5

Z2

A2YF(L)2Y 6 x 2 x 0.8

V7

P5.1

33 3

C16 B16 B16 B16C16 B16 B16 B16

25/0.03A

L1/L2/L3/PEN, 400/230V, 50 Hz

C16 B16 B16 B16C16 B16 B16 B16

25A

L i g h t i n g

B e l e u c h t u n g

O u t l e t s

S t e c k d o s e n

S p a r e

R e s e r v e

N Y

C W

Y

X

C16 C16

S p a r e

R e s e r v e

3 3

Mover 1

NH00

63A

S t e c k d o s e

L a g e g e r a e t

O u t l e t c h a r g i n g u n i t

50-63

32-40

T A

R G

E T

S

E X I

S T I

N G

Z I

E L

B

S T

A N

D

Fahrzeugziel 1

32-40

EXISTING/BESTAND

SCHEMATIC LOW VOLTAGE DISTRIBUTION MOVERS

SCHEMATIK NIEDERSPANNUNGSVERTEILUNGEN FAHRZEUGZIELE

N Y

Y x

32-40

20614

C16 B16 B16 B16C16 B16 B16 B16

25/0.03A

L1/L2/L3/PEN, 400/230V, 50 Hz

C16 B16 B16 B16C16 B16 B16 B16

25A

L i g h t i n g

B e l e u c h t u n g

O u t l e t s

S t e c k d o s e n

S p a r e

R e s e r v e

N Y

C W

Y

X

C16 C16

S p a r e

R e s e r v e

NH00

63A

S t e c k d o g e g e r a e t

O u t l e t c h a r g i n g u i t

50-63

32-40

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

32-40

EXISTING/BESTAND

20615

C16 B16 B16 B16C16 B16 B16 B16

25/0.03A

L1/L2/L3/PEN, 400/230V, 50 Hz

C16 B16 B16 B16C16 B16 B16 B16

25A

L i g h t i n g

B e l e u c h t u n g

O u t l e t s

S t e c k d o s e n

S p a r e

R e s e r v e

N Y

C W

Y

C16 C16

S p a r e

R e s e r v e

NH00

63A

O u t l e t c h a r g i g u i t

50-63

32-40

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

32-40

EXISTING/BESTAND

32-40

20616

Mover 2

Fahrzeugziel 2 NYCWY 3x16/16

NYCWY 3x95/50

Mover 3

Fahrzeugziel 3

N Y

C W

N Y

C W

Y

X

NYCWY 3x50/25

N Y

C W

Y

X

INSTALLATION

PROJECT TITLE

SHEET TITLE

DATE

DATE

DATE

DATE

DRAWN BY PROJECT ENGR CHECKED BY

DATE PROJECT NO

SHEET

OF

SIGNATURE SIGNATURE

SIGNATURE

Training Area Grafenwoehr GM 31P

SIGNATURE

SIGNATURE

MASTER PLANNERRES SECTION

ENGINEERING DIV

ERWIN SCHMIEGERERWIN SCHMIEGER

DATE DESCRIPTION DRAWN BY APPROVEDREV NO

USER/RANGE OPERATIONS

RTLPSAFETY

SIGNATURE

DATE

ERWIN SCHMIEGER, RES DESIGNER

DATE

USA GARRISON BAVARIA

JOHN A. HOWARD, C/Engr Div

SCALE

REVIEW: PREFINAL 19 NOVEMBER 2018

JEFFREY F. ANDERSON, LTC, FA, C/RANGE OPS

DUWAIN S. MARING, C/RTLP

USAG BAVARIA/RES BRANCH/ENG DIV

DAVID A. TASKER, C/Master Planning

Repair Electrical and Data System, Range 206

TI-00620-8J

SCHEMA DATENKABEL/ELEKTROVERTEILUNGEN

SCHEMATIC DATA CABLING/ELECTRICAL DISTRIBUTIONS

20615

20614

20616 inactive

32-40

N x

33 3 3

TROLLEY SHELTER, MOVING TARGET

UNTERSTELLGEBAEUDE, ZIELWAGEN

SCALE 1 : 50

TROLLEY SHELTER 4,8 m x 6,2 m

WAGENUNTERSTAND 4,8 m x 6,2 m

CJB

SCHEMA: DATA CABLING RANGE 206

SCHEMA: DATENVERKABELUNG RANGE 206

CJB

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

S t e c k d o g e g e r a e t

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

LIMIT MARKER

LIMIT MARKER

CEE

14 NOV 2018 1 : 50

T A

R G

E T

I

S T I

N G

Z I

E L

S T

A N

D

JOHN S. DARLINGTON, SAFETY DIRECTOR

ELEKTROKABEL NYY 4 x 16/ERDUNG V4A

POWER CABLE NYY 4 x 16/GROUNDING V4A

FINAL SUBMISSION: 24 JANUARY 2019

File details come from the government source that posted it.