TOWER
A2YF(L)2Y 6 x 2 x 0.8
NEW/NEU
A2YF(L)2Y 6 x 2 x 0.8
EXISTING/BESTAND
DATA SLEEVE
MUFFE, DATEN
P1.4 P1.1
P1.2
P1.3
P2.1 P2.2
P2.3 P2.4
P2.5 P2.6
P3.1 P3.2
P3.3
P3.4
P4.1 P4.2
P4.3 P4.4
P11.1 P11.2
P11.3
P11.4
P11.5
P11.6
MOVER 1
MOVER 2
MOVER 3
P5.4
P5.3
P5.2
P6.1 P6.2
P6.3 P6.4
V4
V3
V1
Z1
V2
BP1
P7.4
P7.3 P7.2
P7.1
P8.4 P8.3
P8.2 P8.1
P10.4 P10.3
P10.2 P10.1
P9.4
P9.3
P9.2 P9.1
Z3
V11
V12
V10
V9
V8
V6
BP2
V5
Z2
A2YF(L)2Y 6 x 2 x 0.8
V7
P5.1
33 3
C16 B16 B16 B16C16 B16 B16 B16
25/0.03A
L1/L2/L3/PEN, 400/230V, 50 Hz
C16 B16 B16 B16C16 B16 B16 B16
25A
L i g h t i n g
B e l e u c h t u n g
O u t l e t s
S t e c k d o s e n
S p a r e
R e s e r v e
N Y
C W
Y
X
C16 C16
S p a r e
R e s e r v e
3 3
Mover 1
NH00
63A
S t e c k d o s e
L a g e g e r a e t
O u t l e t c h a r g i n g u n i t
50-63
32-40
T A
R G
E T
S
E X I
S T I
N G
Z I
E L
B
S T
A N
D
Fahrzeugziel 1
32-40
EXISTING/BESTAND
SCHEMATIC LOW VOLTAGE DISTRIBUTION MOVERS
SCHEMATIK NIEDERSPANNUNGSVERTEILUNGEN FAHRZEUGZIELE
N Y
Y x
32-40
20614
C16 B16 B16 B16C16 B16 B16 B16
25/0.03A
L1/L2/L3/PEN, 400/230V, 50 Hz
C16 B16 B16 B16C16 B16 B16 B16
25A
L i g h t i n g
B e l e u c h t u n g
O u t l e t s
S t e c k d o s e n
S p a r e
R e s e r v e
N Y
C W
Y
X
C16 C16
S p a r e
R e s e r v e
NH00
63A
S t e c k d o g e g e r a e t
O u t l e t c h a r g i n g u i t
50-63
32-40
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
32-40
EXISTING/BESTAND
20615
C16 B16 B16 B16C16 B16 B16 B16
25/0.03A
L1/L2/L3/PEN, 400/230V, 50 Hz
C16 B16 B16 B16C16 B16 B16 B16
25A
L i g h t i n g
B e l e u c h t u n g
O u t l e t s
S t e c k d o s e n
S p a r e
R e s e r v e
N Y
C W
Y
C16 C16
S p a r e
R e s e r v e
NH00
63A
O u t l e t c h a r g i g u i t
50-63
32-40
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
32-40
EXISTING/BESTAND
32-40
20616
Mover 2
Fahrzeugziel 2 NYCWY 3x16/16
NYCWY 3x95/50
Mover 3
Fahrzeugziel 3
N Y
C W
N Y
C W
Y
X
NYCWY 3x50/25
N Y
C W
Y
X
INSTALLATION
PROJECT TITLE
SHEET TITLE
DATE
DATE
DATE
DATE
DRAWN BY PROJECT ENGR CHECKED BY
DATE PROJECT NO
SHEET
OF
SIGNATURE SIGNATURE
SIGNATURE
Training Area Grafenwoehr GM 31P
SIGNATURE
SIGNATURE
MASTER PLANNERRES SECTION
ENGINEERING DIV
ERWIN SCHMIEGERERWIN SCHMIEGER
DATE DESCRIPTION DRAWN BY APPROVEDREV NO
USER/RANGE OPERATIONS
RTLPSAFETY
SIGNATURE
DATE
ERWIN SCHMIEGER, RES DESIGNER
DATE
USA GARRISON BAVARIA
JOHN A. HOWARD, C/Engr Div
SCALE
REVIEW: PREFINAL 19 NOVEMBER 2018
JEFFREY F. ANDERSON, LTC, FA, C/RANGE OPS
DUWAIN S. MARING, C/RTLP
USAG BAVARIA/RES BRANCH/ENG DIV
DAVID A. TASKER, C/Master Planning
Repair Electrical and Data System, Range 206
TI-00620-8J
SCHEMA DATENKABEL/ELEKTROVERTEILUNGEN
SCHEMATIC DATA CABLING/ELECTRICAL DISTRIBUTIONS
20615
20614
20616 inactive
32-40
N x
33 3 3
TROLLEY SHELTER, MOVING TARGET
UNTERSTELLGEBAEUDE, ZIELWAGEN
SCALE 1 : 50
TROLLEY SHELTER 4,8 m x 6,2 m
WAGENUNTERSTAND 4,8 m x 6,2 m
CJB
SCHEMA: DATA CABLING RANGE 206
SCHEMA: DATENVERKABELUNG RANGE 206
CJB
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
S t e c k d o g e g e r a e t
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
LIMIT MARKER
LIMIT MARKER
CEE
14 NOV 2018 1 : 50
T A
R G
E T
I
S T I
N G
Z I
E L
S T
A N
D
JOHN S. DARLINGTON, SAFETY DIRECTOR
ELEKTROKABEL NYY 4 x 16/ERDUNG V4A
POWER CABLE NYY 4 x 16/GROUNDING V4A
FINAL SUBMISSION: 24 JANUARY 2019