05_Drawing_Sheet_3_of_4.pdf
PDF 221 KB Posted
- Solicitation number
- W912PB19Q8013
About this file
Drawing, Sheet 3 of 4
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 03_Drawing_Sheet_1_of_4.pdf | ||
| 04_Drawing_Sheet_2_of_4.pdf | ||
| 06_Drawing_Sheet_4_of_4.pdf | ||
| 01_Solicitation_W912PB19Q8013.pdf | ||
| 02_Attachment_I,_Specification_14Mar19.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCHARNIER
HINGE
SCHARNIER
HINGE
CJB FRONT VIEW
CJB VORDERANSICHT
31230
CJB TOP VIEW
CJB DRAUFSICHT
CJB SIDE VIEW
CJB SEITENANSICHT
BOLT M5 x 30
BOLZEN M5 x 30
BOLT M5 x 30
BOLZEN M5 x 30
BOLZEN M8
BOLT M8
50 50 m a x i m a l m m
CABLE JUNCTION BOX PERSONNEL TARGET
CJB FRONT VIEW
CJB VORDERANSICHT
DATA
DATEN
POWER
ELEKTRO
KABELANSCHLUSSKASTEN PERSONENZIEL
OPENING POWER
OEFFNUNG ELEKTRO
DATA OPENINGS AS REQUIRED
DATEN-OEFFNUNGEN WIE BENOETIGT
BOLZEN M8 ERDUNG
GROUNDING BOLT M8
NOTES / ANMERKUNGEN :
4. ALL CABLE LEAD-IN TO BE WATER TIGHT, IN STEEL.
6. THE INSTALLATION CARRIER MUST BE EQUPPED WITH FOUR BOLTS M5 X 30MM FOR LATER
SLOPE OF THE BOX APPR. 1:10
NEIGUNG DES KASTEN CA. 1:10
CABLE AT THE POINT OF ENTRANCE.
1. ENCLOSURE SHALL BE HIGH-GRADE STEEL, DIMENSIONS: 500mm x 4OOmm x 210mm.
GEHAEUSE AUS EDELSTAHL, ABMESSUNGEN: 500mm x 400mm x 210mm, IP 66, NEMA 4X
ALLE KABELEINFUEHRUNGEN SIND WASSERDICHT, IN EDELSTAHL, AUSZUFUEHREN.
ALL OPENINGS WITHOUT CABLES MUST BE CLOSED WITH PLASTIC BLIND STOPPER
TO BE WATER TIGHT.
ALLE OEFFNUNGEN OHNE KABEL SIND MIT KUNSTSTOFFBLINDSTOPFEN, WASSERDICHT, ZU SCHLIESSEN.
UM DIE MONTAGE DER VIER GEWINDEBOLZEN M5 X 30MM (PARAGRAPH 6) ZU ERMOEGLICHEN.
DIE MONTAGEPLATTE IST MIT VIER STEHBOLZEN M5 X 30MM ZU BESTUECKEN ZUR SPAETEREN
8. DATACABLES MUST BE GROUNDED AT THE CJB CASING
DATENKABELSCHIRME AM GEHAEUSE DATENANSCHLUSSKASTEN ERDEN
IP 66, NEMA 4X
DECKELSCHARNIERE LINKS, BZW. RECHTS MONTIERT, ABHAENGIG VOM MONTAGEORT DES KASTENS IN DER
ZIELGRUBE
3. DOOR HINGES MOUNTED LEFT, RESPECTIVELY RIGHT SIDE, DEPENDING ON THE LOCATION OF THE BOX AT
THE TARGET EMPLACEMENT
INSTALLATION OF AN ADDITIONAL CARRIER FOR ELECTRONIC EQUIPMENT.
MONTAGE EINER ZUSAETZLICHEN MONTAGEPLATTE FUER ELEKTRONIKBAUTEILE.
ALLE FREIEN KABELENDEN SIND DAUERHAFT, AN DER EINLASS-STELLE, ZU KENNZEICHNEN.
2. SECURE GROUND WIRE TO BOX UNDER AT EXTERIOR BOLT, M8. PROVIDE GROUNDING CONNECTION
OF THE BOX DOOR AND THE BOX ITSELF
ERDLEITER AM AEUSSEREN BOLZEN, M8, DES KASTENS FESTKLEMMEN. ERDUNGSVERBINDUNG ZWISCHEN
GEHAEUSETUER UND DEM GEHAEUSE HERSTELLEN
5. INSTALLATION CARRIER MUST BE INSTALLED AT BOLTS AND EQUIPPED WITH 12 SEPARATION
BESTUECKT MIT VIER EDELSTAHLLASCHEN, MIT BOHRLOCH ZUR MONTAGE AUF DEN BODEN
9. ALL CABLE PIGTAILS WILL BE TAGGED WITH PERMANENT TAGS ATTACHED TO THE
STEEL SUPPORTS, WITH HOLE FOR MOUNTING TO GROUND
CABLE JUNCTION BOX CJB
KABELANSCHLUSSKASTEN CJB
INSTALLATION
PROJECT TITLE
SHEET TITLE
DATE
DATE
DATE
DATE
DRAWN BY PROJECT ENGR CHECKED BY
DATE PROJECT NO
SHEET
OF
SIGNATURE SIGNATURE
SIGNATURE
Training Area Grafenwoehr GM 31P
SIGNATURE
SIGNATURE
MASTER PLANNERRES SECTION
ENGINEERING DIV
ERWIN SCHMIEGERERWIN SCHMIEGER
DATE DESCRIPTION DRAWN BY APPROVEDREV NO
USER/RANGE OPERATIONS
RTLPSAFETY
SIGNATURE
DATE
ERWIN SCHMIEGER, RES DESIGNER
DATE
USA GARRISON BAVARIA
JOHN A. HOWARD, C/Engr Div
SCALE
REVIEW: PREFINAL 19 NOVEMBER 2018
JEFFREY F. ANDERSON, LTC, FA, C/RANGE OPS
DUWAIN S. MARING, C/RTLP
USAG BAVARIA/RES BRANCH/ENG DIV
DAVID A. TASKER, C/Master Planning
7. MOUNTING OF THE BOX AT CONCRETE BASE (PERSONNEL TARGETS) - BOX EQUIPPED WITH FOUR HIGH GRADE
DER KASTEN WIRD AUF EINE BETONBODENPLATTE MONTIERT (PERSONENZIELE) - KASTEN
TERMINALS, 2 GROUNDING TERMINALS AND 3 ELECTRICAL TERMINATIONS, MOUNTED AT A CARRIER RAIL. NOTICE
MINIMUM SIZE OF THE CARRIER TO ALLOW THE INSTALLATION OF THE TREADED BOLTS M5 X 30MM (PARAGRAPH 6).
DIE MONTAGEPLATTE IST AUF STEHBOLZEN ZU MONTIEREN UND MIT 12 TRENNKLEMMEN, 2 ERDUNGSKLEMMEN UND
3 ELEKTRO-REIHENKLEMMEN AUF TRAGSCHIENE ZU BESTUECKEN. MINDESTABMESSUNG DER MONTAGEPLATTE BEACHTEN,
10. PROVIDE 50 CM OF SLACK DATA CABLES IN THE CJB.
50 cm KABELLAENGE DER DATENKABEL IM ANSCHLUSSKASTEN AUFROLLEN.
ELECTRICAL POWER PANEL
NIEDERSPANNUNGSVERTEILER
TOP VIEW
DRAUFSICHT
DATA CONNECTION BOX
DATENANSCHLUSSKASTEN
POTENTIAL EQUALIZATION BUSBAR
POTENTIALAUSGLEICHSSCHIENE
RUBBER MAT
GUMMIMATTE
ELECTRICAL POWER PANEL
NIEDERSPANNUNGSVERTEILER
CJB
CJB
POTENTIAL EQUALIZATION BUSBAR
A A
DATA CABLES
DATENKABEL
POTENTIALAUSGLEICHSSCHIENE
SECTION A-A, SAT
SCHNITT A-A, SAT
VEHICLE TARGET PIT (SAT)
FAHRZEUGZIELGRUBE (SAT)
SIDE VIEW
ELECTRICAL POWER PANEL
NIEDERSPANNUNGSVERTEILER
POTENTIAL EQUALIZATION BUSBAR
POTENTIALAUSGLEICHSSCHIENE
CJB
RUBBER MAT
GUMMIMATTE
SEITENANSICHT
TOP VIEW
ELECTRICAL POWER PANEL
NIEDERSPANNUNGSVERTEILER
DRAUFSICHT
POTENTIAL EQUALIZATION BUSBAR
POTENTIALAUSGLEICHSSCHIENE
CJB
BETONFERTIGTEIL BESTAND
CONCRETE PREFAB ELEMENT EXISTING
PERSONNEL TARGET PIT (SIT)
PERSONENZIEL (SIT)
1 : 20
SCALE
MASSTAB
1 : 20
SCALE
MASSTAB
SCALE
MASSTAB
1 : 5
CONCRETE PREFAB ELEMENT EXISTING
BETONFERTIGTEIL BESTAND
Details: Target Emplacements with electrical/data installations, CJB
Details: Zielgruben mit Elektro/Dateneinbauten, CJB
Repair Electrical and Data System, Range 206
TI-00620-8J1 : 20, 1 : 514 NOV 2018
ELECTRICAL POWER PANEL
NIEDERSPANNUNGSVERTEILER
POTENTIAL EQUALIZATION BUSBAR
POTENTIALAUSGLEICHSSCHIENE
PROTECTION CONDUIT
KABELSCHUTZROHR
CONCRETE PREFAB ELEMENT
BETONFERTIGTEIL
BALKENWINKEL
BEAM SUPPORT
PROTECTION TIMBER 25/15
SCHUTZHOLZ 25/15
1 : 20
SCALE
MASSTAB
L-SHAPE ELEMENT LIMIT MARKER
L-FORM FERTIGTEIL BEGRENZER
JOHN S. DARLINGTON, SAFETY DIRECTOR
FINAL SUBMISSION: 24 JANUARY 2019
File details come from the government source that posted it.