Amendment 1 - Attachment 2 - W912P924B0002 Bid Schedule STL Combined Sewer Overflow Rehabilitation Project 21 NOV 2023.xlsx
XLSX spreadsheet 17 KB Posted
- Solicitation number
- W912P924B0002
About this file
This document contains a bid schedule for solicitation number W912P924B0002 from the Department of the Army Corps of Engineers Engineering District St Louis for the St. Louis Missouri Combined Sewer Overflow Rehabilitation Project. The bid schedule outlines various cleaning, lining, and repair services required for sewer pipes and manholes in sizes ranging from 6 to 48 inches in diameter. It also includes requirements for bypass pumping, heavy cleaning, lateral repairs, manhole frame replacements and adjustments, cementitious lining installation, and pavement repair. Pricing is to be provided per unit of measure for each line item, with quantities estimated. Site-specific service connection repairs are also included at multiple locations. Option 1 involves bypass pumping services while Option 2 requires heavy cleaning services.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| CLIN | Description | Unit | Quantity | Unit Price | Unit Total |
| Harlem Baden 9 | |||||
| A001 | Mobilization and Demobilization | JOB | 1 | ||
| A002 | Protection and Restoration of Site | JOB | 1 | ||
| A003 | Manhole Frame Seals | EA | 148 | ||
| A004 | Manhole Cover Seals | EA | 148 | ||
| A005 | CIPP Liner - 6" Dia Pipe | LF | 474 | ||
| A006 | CIPP Liner - 8" Dia Pipe | LF | 6370 | ||
| A007 | CIPP Liner - 10" Dia Pipe | LF | 1021 | ||
| A008 | CIPP Liner - 12" Dia Pipe | LF | 3188 | ||
| A009 | CIPP Liner - 15" Dia Pipe | LF | 1260 | ||
| A010 | CIPP Liner - 18" Dia Pipe | LF | 1135 | ||
| A011 | CIPP Liner - 21" Dia Pipe | LF | 912 | ||
| A012 | CIPP Liner - 24" Dia Pipe | LF | 601 | ||
| A013 | CIPP Liner - 27" Dia Pipe | LF | 277 | ||
| A014 | CIPP Liner - 30" Dia Pipe | LF | 410 | ||
| A015 | CIPP Liner - 36" Dia Pipe | LF | 435 | ||
| A016 | CIPP Liner - 39" & 42" Dia Pipe | LF | 686 | ||
| A017 | CIPP Liner - 48" Dia Pipe | LF | 906 | ||
| A018 | Sewer Re-connections 6" - 24" Dia | EA | 527 | ||
| A019 | Sewer Re-connections over 24" Dia | EA | 54 | ||
| A020 | Point Repair - Under 10 Feet Deep - Street | EA | 7 | ||
| A021 | Point Repair - Over 10 Feet Deep - Street | EA | 5 | ||
| A022 | Cleaning and CCTV - 6-12" Dia Pipe | LF | 11053 | ||
| A023 | Cleaning and CCTV - 15" Dia Pipe | LF | 1260 | ||
| A024 | Cleaning and CCTV - 18" Dia Pipe | LF | 1135 | ||
| A025 | Cleaning and CCTV - 21" Dia Pipe | LF | 912 | ||
| A026 | Cleaning and CCTV - 24" Dia Pipe | LF | 601 | ||
| A027 | Cleaning and CCTV - 27" Dia Pipe | LF | 277 | ||
| A028 | Cleaning and CCTV - 30" Dia Pipe | LF | 410 | ||
| A029 | Cleaning and CCTV - 36" Dia Pipe | LF | 435 | ||
| A030 | Cleaning and CCTV - 39" & 42" Dia Pipe | LF | 686 | ||
| A031 | Cleaning and CCTV - 48" Dia Pipe | LF | 906 | ||
| A032 | Service Connection Repair - 6-12" Dia Pipe | EA | 402 | ||
| A033 | Service Connection Repair - Over 12-18" Dia Pipe | EA | 78 | ||
| A034 | Service Connection Repair - Over 18-21" Dia Pipe | EA | 42 | ||
| A035 | Service Connection Repair - Over 21-24" Dia Pipe | EA | 5 | ||
| A036 | Service Connection Repair - Site 1 | JOB | 1 | ||
| A037 | Service Connection Repair - Site 2 | JOB | 1 | ||
| A038 | Service Connection Repair - Site 3 | JOB | 1 | ||
| A039 | Service Connection Repair - Site 4 | JOB | 1 | ||
| A040 | Service Connection Repair - Site 5 | JOB | 1 | ||
| A041 | Service Connection Repair - Site 6 | JOB | 1 | ||
| A042 | Service Connection Repair - Site 7 | JOB | 1 | ||
| A043 | Service Connection Repair - Site 8 | JOB | 1 | ||
| A044 | Service Connection Repair - Site 9 | JOB | 1 | ||
| A045 | Service Connection Repair - Site 10 | JOB | 1 | ||
| A046 | Service Connection Repair - Site 11 | JOB | 1 | ||
| A047 | Service Connection Repair - Site 12 | JOB | 1 | ||
| A048 | Service Connection Repair - Site 13 | JOB | 1 | ||
| A049 | Manhole Frame and Cover, Remove and Replace (includes 1 foot masonry) | EA | 22 | ||
| A050 | Install Cementitious Lining | LF | 1524 | ||
| A051 | Adjust to Grade in Pavement | LF | 17 | ||
| A052 | Pavement | SY | 780 |
| MSD Infrastructure 2023 | |||
| B001 | Mobilization and Demobilization | JOB | 1 |
| B002 | CIPP Liner - 15" Dia Pipe - 07.5 MM | LF | 12295 |
| B003 | CIPP Liner - 18" Dia Pipe - 06 MM | LF | 170 |
| B004 | CIPP Liner - 18" Dia Pipe - 07.5 MM | LF | 14511 |
| B005 | CIPP Liner - 18" Dia Pipe - 09 MM | LF | 3324 |
| B006 | CIPP Liner - 18" Dia Pipe - 11 MM | LF | 80 |
| B007 | CIPP Liner - 21" Dia Pipe - 09 MM | LF | 5530 |
| B008 | CIPP Liner - 21" Dia Pipe - 11 MM | LF | 314 |
| B009 | CIPP Liner - 24" Dia Pipe - 10.5 MM | LF | 2899 |
| B010 | Point Repair - Under 10 Feet Deep (not underneath pavement) | EA | 2 |
| B011 | Point Repair - Under 10 Feet Deep - Street | EA | 2 |
| B012 | Point Repair - 10 to 15 Feet Deep (not underneath pavement) | EA | 2 |
| B013 | Point Repair - 10 to 15 Feet Deep - Street | EA | 2 |
| B014 | Install Cured-In-Place Chimney Liner (hazardous) | LF | 10 |
| B015 | Install Chimney Liner (non-hazardous) | LF | 50 |
| B016 | Sewer Re-connections 6" - 24" Dia | EA | 400 |
| B017 | Cleaning and CCTV - 15" Dia Pipe | LF | 12295 |
| B018 | Cleaning and CCTV - 18" Dia Pipe | LF | 18085 |
| B019 | Cleaning and CCTV - 21" Dia Pipe | LF | 5844 |
| B020 | Cleaning and CCTV - 24" Dia Pipe | LF | 2899 |
| B021 | Manhole Frame and Cover, Remove and Replace | EA | 5 |
| B022 | Manhole Frame and Cover, Adjustment (includes first foot of new masonry) | EA | 5 |
| B023 | Manhole Masonry (Greater than One Foot) | LF | 5 |
| B024 | Locate Buried Manholes | EA | 10 |
| B025 | Lateral Repair Non-Person Entry | EA | 10 |
| B026 | Lateral Repair Person Entry | EA | 10 |
| B027 | Install Cementitious Liner | LF | 350 |
| OPTION 1 - Harlem Baden 9 | |||
| C001 | Bypass Pumping (over 1000 GPM) | JOB | 1 |
| OPTION 2 - MSD Infrastructure 2023 | |||
| D001 | Heavy Cleaning | JOB | 1 |
File details come from the government source that posted it. Updated .