This solicitation package outlines requirements for a competitive small business set-aside contract to perform power distribution upgrades at Locks No. 27. Work includes furnishing equipment, labor, engineering services, site supervision, and materials to upgrade electrical systems. The U.S. Army Corps of Engineers, St. Louis District will issue solicitation W912P9-19-B-0007 with a closing date for bids contained in the package. The solicitation style is an Invitation for Bid and the North American Industry Classification System code is 237990 for heavy and civil engineering construction. The size standard for eligibility is $36.5 million. The solicitation package will be available on www.fedbizopps.gov and interested parties must register on SAM to be eligible for award.
PLANS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912P919B0007-0003.pdf | ||
| W912P919B0007-0001-Amendment.pdf | ||
| A22-19B0007-SOL.pdf | ||
| A02-19B0007-27_PwrDist_Upgrades_Adv_specs.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
M
AR
K D
ES
C
R
IP
TI
O
N
ST._LOUIS_DISTRICT
/ G001M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M B
ER
:M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
SAINT LOUIS DISTRICT
W912P9-19-B-0007
CONTRACT NO.:
ISSUE DATE: OCTOBER 2019
VOLUME: 1
CO
VE
R
SH
EE
T
LOWER MISSISSIPPI RIVER
LOCKS NO. 27
ELECTRICAL
M-LM-84
LOCKS NOS. 27 AT 3291 W 20TH ST. GRANITE CITY, IL 62040
G
EN
ER
AL
AFF
AFG
A, AMP
BC
BFF
BKR
BOT
C
CA
CAB
CAX
CL
CKT
CP
CU
CR
CT
DN
DWG
EGC
EL
EMT
ENT
EQPT
ETC.
ES
E-STOP
EX
EXP
EXP
FCV
FDR
FJ
FSL
FWE
FX
GEC
GFI
GND
GFCI
HD
HOI
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPACITY
BARE COPPER
BELOW FINISHED FLOOR
BREAKER
BOTTOM
CONDUIT
CABLE
CABINET
CABLE REEL
CENTER LINE
CIRCUIT
CONTROL PANEL
COPPER
CONVENIENCE RECEPTACLE
CABLE TRAY
DOWN
DRAWING
EQUIPMENT GROUNDING CONDUCTOR
ELEVATION
ELECTRICAL METALLIC TUBING
ELECTRICAL NONMETALLIC TUBING
EQUIPMENT
ETCETERA
END SEAL
EMERGENCY STOP
EXISTING
EXPLOSION-PROOF
FLOW CONTROL VALVE
FLOW CONTROL VALVE
FEEDER
FIELD INSTALLED JUMPER
FLOW SWITCH LOW
FURNISHED WITH EQUIPMENT
LIGHTING FIXTURE
GROUNDING ELECTRIC CONDUCTOR
GROUND FAULT INTERUPTOR
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
HEAT DETECTOR
HOIST
HPU
HS
HT
HTC
HTR
J-BOX
KV
KVA
KW
LC
LS
LSH
LSL
LSLL
M
MC
M/C
MCC
MCP
MH
MTD
N
N.C.
N.O.
NIC
NTS
O.C.
OC
Φ/PH
P
PB
PDSH
PNL
PT
RAL
REF
RGS
HYDRAULIC POWERT UNIT
HAND SWITCH
HEAT TRACE
HEAT TRACE POWER CONNECTION
HEATER
JUNCTION BOX
KILO VOLT
KILO VOLT AMP
KILO WATT
LIGHTING CABINET
LEVEL SWITCH
LEVEL SWITCH HIGH
LEVEL SWITCH LOW
LEVEL SWITCH LOW-LOW
ELECTRONIC MOTOR
METAL CLAD CABLE
MULTICONDUCTOR
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR (MAGNETIC ONLY)
MOUNTING HEIGHT (AFF)
MOUNTED
NEUTRAL
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OBSERVATION CAMERA
PHASE
POLE
PANELBOARD
PRESSURE DIFFERENTIAL SWITCH HIGH
PANEL
PRESSURE TRANSMITTER
RIGID ALUMINUM
REFERENCE
RIGID GALVANIZED STEEL
ABBREVIATIONS NOTE: NOT ALL ABBR/DEVICES SHOWN ARE USED
SYSTEM SWITCH
SPLICE CONNECTION
SPEED SWITCH
SPEED SWITCH - LOW
SOLENOID VALVE
SPEED TRANSMITTER
SWITCH
TERMINAL BOX
TEMP, ELEMENT
TRANSFORMER
TEMPERATURE SWITCH LOW
TEMPERATURE TRANSMITTER
TEMP, TRANSMITTER
TYPICAL
UNDERGROUND DUCT BANK
VOLT
VOLT-AMP
VARIABLE FREQUENCY DRIVE
VIBRATION SWITCH HIGH
WATT
WARNING LIGHT
WEATHERPROOF
WATERPROOF WHILE IN USE
WELDING RECEPTACLE
WEIGHT INTEGRATER
EXPLOSION PROOF
EXPLOSION PROOF WHILE IN USE
ALARM HORN
POSITION SWITCH
LIMIT SWITCH CLOSED
LIMIT SWITCH HIGH
LIMIT SWITCH OPEN
POSITION TRANSMITTER
S/S
SC
SS
SSL
SV
ST
SW
TB
TE
TR
TSL
TT
TX
TYP
UDB
V
VA
VFD
VSH
W
WL
WP
WPIU
WR
WT
XP
XPIU
YA
ZS
ZSC
ZSH
ZSO
ZT
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ G002M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
DR
AW
IN
G
LI
ST
,S
YM
BO
LS
AB
BR
EV
IA
TI
O
NS
LOCKS NOS. 27
AT 3291 W 20TH ST.
GRANITE CITY, IL
62040
M-LM-84-E604 SINGLE LINE DIAGRAM MAIN LOCK MCCPB & MCC3
M-LM-84-E205 RISER DIAGRAM MCCPB AT GENERATOR BUILDING
M-LM-84-ED205 DEMO- OUTAGE 2- RISER DIAGRAM MCCPB AT GENERATOR BUILDING
M-LM-84-E201 ELEVATION AND DETAILS -RESERVED
M-LM-84-E200 ELEVATION AND DETAILS - NEW TRANSFORMER PLACEMENT
M-LM-84-E105 SITE PLAN - GROUNDING
M-LM-84-E104 SITE PLAN - NEW TRANSFORMER AREA
M-LM-84-E103 SITE PLAN - INCOMING UTILITY
M-LM-84-ED101 DEMO - OUTAGE 2 - DEMOLITION AND RELOCATION
M-LM-84-ED100 DEMO - OUTAGE 2 - DEMOLITION AND RELOCATION
M-LM-84-C101 CIVIL SITE PLAN
SUMMARY OF WORK DWG. PACKAGE NO. 2
M-LM-84-E900 REFERENCE PHOTOS OUTAGE 1
M-LM-84-E604 SINGLE LINE DIAGRAM MAIN LOCK MCCPB & MCC3
M-LM-84-E603 MCC 5 & LP7, NEW HOG SHED PANEL
M-LM-84-E601 SINGLE LINE DIAGRAM MCC2
M-LM-84-E600 SINGLE LINE DIAGRAM MAIN SWITCHBOARD
M-LM-84-E202 RISER DIAGRAM MAIN SWBD
M-LM-84-E102 SITE PLAN - HOG SHED AREA
M-LM-84-E101 SITE PLAN - MCC2 NEW FEEDER
SUMMARY OF WORK DWG. PACKAGE NO. 1
M-LM-84-G100 OVERALL SITE PLAN
M-LM-84-G003 SUMMARY OF WORK
M-LM-84-G002 DRAWING LIST, SYMBOLS & ABBREVIATIONS
M-LM-84-G001 COVER SHEET
GENERAL
DWG # DRAWING TITLE
DRAWING LIST
G
EN
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ G003M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
BR
E
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
PD
M
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
SU
M
M
AR
Y O
F W
O R
K
SUMMARY OF WORK - PREOUTAGE #1 - ELECTRICAL UPGRADES
1. MAIN SWITCHBOARD: CONTRACTOR SHALL PROCURE CIRCUIT BREAKER FOR MAIN SWITCHBOARD AS SPECIFIED ON
DRAWINGS.
2. MCC2 PARALLEL FEEDERS: CONTRACTOR SHALL FURNISH NEW PARALLEL FEEDERS FROM THE MAIN SWITCHBOARD TO MCC2 PER THE DRAWINGS. FEEDERS SHALL BE INSTALLED IN EXISTING TRAYS. FEEDERS SHALL BE TERMINATED DURING
OUTAGE #1.
3. MCC3 BREAKER REPLACEMENTS: CONTRACTOR SHALL SUPPLY NEW 480V/3P CIRCUIT BREAKERS FOR CUBICLES 3A AND 4C
(WHICH SERVE MCC4) AS SPECIFIED ON THE DRAWINGS.
4. MCC5 BREAKER REPLACEMENTS: CONTRACTOR SHALL SUPPLY NEW 480V/3P CIRCUIT BREAKERS FOR EXISTING BREAKERS
1BC, 1SL, 1EL & 1QL AS SPECIFIED ON THE DRAWINGS.
5. NEW FEEDER AND PANEL TO "HOG SHED": CONTRACTOR SHALL REPLACE THE EXISTING PANEL IN THE SHED. CONTRACTOR SHALL FURNISH NEW FEEDER FROM THE STORAGE BLDG PANEL TO THE HOG SHED PANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRENCHING, EXCAVATION & BACK FILL FOR THE UNDERGROUND WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UNDERGROUND LOCATES OF EXISTING SITE UTILITIES IN THE AREA. CONTRACTOR SHALL RECONNECT THE THREE LIGHTING AND RECEPTACLE CIRCUITS IN THE SHED. ANY OUTAGE REQUIRED OR THIS WORK CAN BE ACCOMPLISHED OUTSIDE OF THE TWO MAIN OUTAGES AND WILL NOT AFFECT LOCK OPERATION.
GENERAL DESCRIPTION OF PROJECT
THE OWNER WISHES TO ACCOMPLISH SOME REPLACEMENTS AND UPGRADES TO THE ELECTRICAL DISTRIBUTION SYSTEM. THE FACILITY IS PRESENTLY SERVED WITH A 4160V SERVICE FROM AMEREN WITH THE MAIN TRANSFORMER AS PART OF THE OWNERS EQUIPMENT. THIS PROJECT WILL CHANGE THE SERVICE FROM 4160V TO A 480V SERVICE FROM AMEREN WITH AMEREN OWNING
THE TRANSFORMER. THE NEW SERVICE WILL REQUIRE WORK PERFORMED BY AMEREN.
AMEREN WORK AND COSTS: CONTRACTOR SHALL COORDINATE THE NEW SERVICE WORK WITH AMEREN. ALL AMEREN CHARGES FOR THE SERVICE SHALL BE PAID BY THE CONTRACTOR AND INCLUDED IN THE BID PRICE. AMEREN SHALL BE PAID LUMPSUM IN
FULL AMOUNT AT AWARD.
PERMITTING COSTS: CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING AND SURVEYING COSTS. PERMITS INCLUDE BUT ARE NOT LIMITED TO USACE SEC. 408, USACE SEC.404 (OR LETTER STATING NO NEED FOR SEC. 404 PERMIT), ILLINOIS LAND DISTURBANCE PERMIT, SEC. 106 CULTURAL RESOURCES PERMIT. ALL CONSTRUCTION PERMITS ARE ALSO THE RESPONSIBILITY
OF THE CONTRACTOR.
NEW MAIN DISCONNECT: THE OWNER REQUIRES A NEW MAIN DISCONNECT ON THE 480V SECONDARY OF THE NEW 4160V TRANSFORMER IN ORDER TO HAVE ISOLATION MEANS OF THE TRANSFER SWITCH AND THE MCC IN THE GENERATOR BUILDING.
BREAKER REPLACEMENT: FOR ARC-FLASH HAZARD REDUCTIONS THE OWNER WISHES TO REPLACE SEVERAL BREAKERS WITH UPGRADED MODELS IN THE EXISTING MAIN SWITCHBOARD, AND EXISTING MCC3 AND MCC5. PARALLEL FEEDERS ARE TO BE
INSTALLED FOR MCC2.
NEW PANEL AND FEEDER: THE OWNER REQUIRES A NEW SMALL PANEL AND FEEDER TO A REMOTE SHED REFERRED TO AS "HOG
SHED" .
OUTAGES: OUTAGES ARE LIMITED TO NO MORE THAN 12 HOURS AND MUST BE SCHEDULED WITH THE OWNER. IT IS ANTICIPATED THAT NO MORE THAN 2-12 HOUR OUTAGES WILL BE NECESSARY TO ACCOMPLISH THE WORK. THE CONTRACTOR SHALL PLAN AND
ACCOMPLISH AS MUCH WORK PRIOR TO ANY OUTAGE SO AS TO MINIMIZE THE OUTAGE TIME.
DEMOLITION: SOME DEMOLITION WORK WILL BE NECESSARY TO THE OLD 4160V SERVICE EQUIPMENT AFTER THE NEW 480V SERVICE IS IN OPERATION. THIS WORK SHOULD NOT REQUIRE ANY ADDITIONAL OUTAGES TO THE FACILITY.
1. NEW 480V SERVICE; : CONTRACTOR SHALL FURNISH THE NEW PRIMARY CONDUIT, TRANSFORMER PAD, GROUNDING SYSTEM, SECONDARY FEEDERS, METERING CABINETS, AND NEW MAIN CIRCUIT BREAKER (MCB).
CONTRACTOR SHALL FURNISH THE NEW FEEDER FROM THE MCB TO THE ATS (FINAL TERMINATION TO BE MADE DURING OUTAGE #2). CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE AMEREN
TRANSFORMER AND ENERGIZATION OF THE NEW SERVICE EQUIPMENT PRIOR TO OUTAGE #2.
AMEREN WORK AND COSTS: CONTRACTOR SHALL COORDINATE THE NEW SERVICE WORK WITH AMEREN.
ALL AMEREN CHARGES FOR THE SERVICE SHALL BE PAID BY THE CONTRACTOR AND INCLUDED IN THE BID
PRICE.
2. GENERATOR BUILDING MCC-PB: CONTRACTOR SHALL FURNISH THIS NEW MCC PER THE DRAWINGS.
SUMMARY OF WORK - OUTAGE #1 - ELECTRICAL UPGRADES
1. MAIN SWITCHBOARD: CONTRACTOR SHALL REPLACE THE BREAKERS IN THE MAIN SWITCHBOARD. NEW SECTION FOR MAIN SWITCHBOARD SHALL HAVE BREAKERS AND CONFIGURATION AS SPECIFIED ON DRAWINGS. WORK INCLUDES DISCONNECTION/RECONNECTION OF EXISTING FEEDERS. CONTRACTOR SHALL TEST/MAINTAIN ROTATION PHASING.
BREAKER SETTINGS SHALL BE DONE BY THE CONTRACTOR PER THE ARC-FLASH STUDY TO BE PROVIDED BY USACE.
2. MCC2 PARALLEL FEEDERS: CONTRACTOR SHALL INSTALL NEW LUGS AT MCC2 MAIN BREAKERS, TERMINATE THE NEW PARALLEL FEEDERS TO THE BREAKERS IN THE MAIN SWITCHBOARD AND AT MCC2. WORK INCLUDES DISCONNECTION/RECONNECTION OF EXISTING FEEDERS, CONTRACTOR SHALL TEST/MAINTAIN ROTATION PHASING.
BREAKER SETTINGS SHALL BE DONE BY THE CONTRACTOR PER THE ARC-FLASH STUDY TO BE PROVIDED BY USACE.
3. MCC3 BREAKER REPLACEMENTS: CONTRACTOR SHALL INSTALL NEW 480V/3P CIRCUIT BREAKERS FOR CUBICLES 3A AND 4C (WHICH SERVE MCC4) AS SPECIFIED ON THE DRAWINGS. WORK INCLUDES DISCONNECTION/RECONNECTION OF EXISTING FEEDERS, CONTRACTOR SHALL TEST/MAINTAIN ROTATION PHASING. BREAKER SETTINGS SHALL BE DONE BY THE
CONTRACTOR PER THE ARC-FLASH STUDY TO BE PROVIDED BY USACE.
4. MCC5 BREAKER REPLACEMENTS: CONTRACTOR SHALL INSTALL NEW 480V/3P CIRCUIT BREAKERS FOR EXISTING BREAKERS 1EL & 1QL (WHICH SERVE MCC7) AS SPECIFIED ON THE DRAWINGS. WORK INCLUDES DISCONNECTION/RECONNECTION OF EXISTING FEEDERS, CONTRACTOR SHALL TEST/MAINTAIN ROTATION PHASING. BREAKER SETTINGS SHALL BE DONE BY THE
CONTRACTOR PER THE ARC-FLASH STUDY TO BE PROVIDED BY USACE.
CONTRACTOR SHALL REMOVE ALL OLD BREAKERS & EQUIPMENT FROM THE SITE AND DISPOSE OF PROPERLY. THE OWNER DOES NOT WISH TO ADD TO THEIR SPARE INVENTORY, BUT MAY ELECT TO KEEP ALL OR PART OF THE OLD COMPONENTS AT
ITS DISCRETION.
SUMMARY OF WORK - PREOUTAGE #2 - NEW SERVICE
SUMMARY OF WORK - OUTAGE #2 - NEW SERVICE
1. MCC-PB: CONTRACTOR SHALL DEMO THE EXISTING MCC AND INSTALL NEW MCC. WORK INCLUDES DISCONNECTION/RECONNECTION OF EXISTING FEEDERS, CONTRACTOR SHALL TEST/MAINTAIN ROTATION PHASING. BREAKER SETTINGS SHALL BE DONE BY THE CONTRACTOR AS SPECIFIED BY THE ENGINEER.
NEW MCC NAMEPLATES TO BE SUPPLIED AND FURNISHED BY CONTRACTOR. ARC FLASH LABELS TO BE
SUPPLIED BY USACE AND INSTALLED BY CONTRACTOR.
2. NEW FEEDER TO ATS: CONTRACTOR SHALL INSTALL NEW FEEDER TO THE EXISTING ATS.
3. CONTRACTOR SHALL DISCONNECT EXISTING FEEDER TO ATS FROM EXISTING TRANSFORMER AND
REMOVE THE EXISTING FEEDER CONDUCTORS (4 SETS OF #350KCMIL) FROM THE EXISTING MANHOLE (#1) THROUGH EXISTING DUCTBANK, TO THE GENERATOR BUILDING CABLE VAULT, BEFORE MCC-PB IN THE
GENERATOR BUILDING.
4. CONNECTION TO EXISTING GROUNDING SYSTEM: CONTRACTOR SHALL FURNISH NEW CONDUCTORS FROM EXISTING MANHOLE #5 TO THE NEW MCC-PB IN THE CONDUIT (FROM OLD FEEDER IN #2) AND
BONDED TO EXISTING GROUND CONDUCTOR IN THE MANHOLE.
5. ABANDON EXISTING CABLES P0003,4,5,6 IN THE CABLE VAULT JUST BELOW THE MCC/ATS. CONTRACTOR SHALL MAKE ALL NEW CONNECTIONS TO THE SYSTEM GROUNDING GRID (NEW AND EXISTING) PER THE
DRAWINGS.
6. EXISTING 4160V SERVICE: CONTRACTOR SHALL REMOVE THE OVERHEAD FUSES FROM THE EXISTING SERVICE POLE AND DISCONNECT AND REMOVE ALL 4160V RISER CABLES FROM THE FUSE HOLDERS TO THE TOPS OF THE RISER CONDUITS. CONTRACTOR SHALL ENSURE THAT THE EXISTING TRANSFORMER IS
DE-ENERGIZED.
SUMMARY OF WORK - POST OUTAGE#2 - DEMOLITION
1. OLD TRANSFORMER: CONTRACTOR SHALL REMOVE ALL PRIMARY CABLING FROM THE RISER POLE TO
THE TRANSFORMER. CONTRACTOR SHALL REMOVE THE SECONDARY CABLES FROM THE
TRANSFORMER TO THE ATS THROUGH THE OLD CONDUITS IN THE DUCT BANK. CONTRACTOR SHALL REMOVE AND DISPOSE OF THE TRANSFORMER, PAD, BOLLARDS, ETC. PER DRAWINGS. CONTRACTOR
SHALL BACKFILL & REPAIR ASPHALT PER DRAWINGS.
2. OVERHEAD LINES AND POLES: CONTRACTOR SHALL REMOVE THE RISER CONDUITS, OVERHEAD LINES, GUY-WIRES, AND WOOD POLES AS SHOWN ON THE DRAWINGS. CONTRACTOR REMOVE FROM THE SITE
AND PROPERLY DISPOSE OF. CONTRACTOR SHALL BACKFILL THE POLE EXCAVATIONS PER THE
DRAWINGS.
3. AMEREN LINES & POLES: AMEREN SHALL REMOVE 3 POLES & OVERHEAD LINES OWNED BY AMEREN.
CONTRACTOR SHALL PAY AMEREN CHARGES FOR THIS WORK. G
EN
E103
E102
POWER
BUILDING
EXISTING UTILITY POLE
EXISTING TRANSFORMER
EXISTING HOG SHED
STORAGE BULDING
("MCC 7 STOR" PANEL
LOCATED HERE)
MCC 2
EXISTING AMEREN
METERING POLE
OVERHEAD LINE POLE
(USACE OWNED)
MCC7
MCC3 & MCC5
MAIN SWBD
E101
MCC PB
I-WALL
WEST WALL (AUX)
EAST WALL (MAIN)
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ G100M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
O
VE
RA
LL
SI
TE
PL
AN
1" = 60'-0"
OVERALL SITE PLAN
N N
TRUE NORTH PLAN NORTH
G
EN
1065'-0"
~130' INSIDE
BUILDING AND
~30' DROP
FROM MCC2
~ 130' INSIDE BUILDING
AND ~30' RISE
TO MAIN SWBD TOTAL ESTIMATED CABLE DISTANCE =~1400'
TRAYS 1008 AND 1009
TRAYS 2000 AND 2001
UNDERGROUND TRAY, SEE
PICTURE ON THIS DRAWING
~ 130' INSIDE
BUILDING
AND ~30' RISE
TO MAIN SWBD
EX. POWER CABLE
TRAYS BETWEEN MAIN
SWB & MCC2
REF PHOTO #1
EX. POWER TRAYS NEAR MAIN SWITCHBOARD
REF PHOTO #4
EX. POWER TRAYS TO MCC2
REF PHOTO #2
MCC2 INCOMING TRAYS (RISER)
REF PHOTO #3
MCC2 MAIN LUGS
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E101M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PL
AN
-M C
C2
NE
W
PA
R
AL
LE
L
FE
ED
ER
1" = 50'-0"
MCC2 NEW PARALLEL FEEDER
GENERAL NOTES
1. MCC2 PARALLEL FEEDERS: CONTRACTOR SHALL FURNISH NEW PARALLEL
FEEDERS FROM THE MAIN SWITCHBOARD TO MCC2 PER THE DRAWINGS.
FEEDERS SHALL BE INSTALLED IN EXISTING TRAYS. CONTRACTOR SHALL
MAINTAIN ROTATION PHASING.
2. FEEDER LENGTHS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE.
CONTRACTOR IS RESPONSIBLE FOR CONDUCTOR LENGTHS FIELD-
VERIFICATION.
KEYED NOTES
1. ROUTE NEW FEEDERS P2004A & P2005A IN SAME TRAYS AS P2004 & P2005.
REFERENCE DRAWINGS
1. SINGLE LINE DIAGRAM & CABLE SCHEDULE DRAWING E-601.
50 50 100 1" = 50'-0"
FEETSCALE
N
EL
EC
TR
IC
A E102
5'
-4
'-0
1.5" UNDERGROUND PVC SCHEDULE 80 CONDUIT.
DIRECT BURY.
24" DEPTH.
NEW 12" x 12" PULLBOX
NEMA 4XSS
SURFACE MOUNT ON TOP OF CONCRETE WALL
B E102
STORAGE
BUILDING
MCC-7
BUILDING
HOG
SHED
EXISTING & NEW
PANEL LOCATION
1.5" RGS ON SURFACE
EXISTING
MAINTENANCE
BUILDING
EXISTING
HOG
STORAGE
NEW LP-HS
EXISTING MCC 7
STORAGE PANEL
1.5" PVC-COATED RGS WITH
CABLE #L2005B
INSTALLED ON TOP
OF CONCRETE WALL
NEW 12"x12" BOX
NEMA 4XSS
B E102
1.5" PVC
SCH.80
CONDUIT
LB
FITTING
2' -0
LB FITTING
1.5" PVC-COATED RGS
(ELBOWS &
VERTICALS)
1.5" PVC-COATED
RGS (ELBOWS &
VERTICALS)
1'-0"
100% COMPACTED
SPOIL BACKFILL
2' -0
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E102M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PL
AN
-H O
G
SH
ED
AR
EA
1/16" = 1'-0"
HOG SHED AREA
1/16" = 1'-0"E102
A NEW HOG SHED FEEDER ELEVATION
REFERENCE PHOTO 1: HOG SHED FEEDER ROUTE
REFERENCE PHOTO 3: HOG SHED EXISTING PANEL REFERENCE PHOTO 4: MCC 7 STORAGE PANEL
DEMO EXISTING HOG
SHED PANEL AND
RISER CONDUIT.
TO HOG SHED PANEL
GENERAL NOTES
1. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
UNDERGROUND LOCATES IN THIS AREA PRIOR TO DIGGING.
2. FEEDER LENGTHS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE.
CONTRACTOR IS RESPONSIBLE OF CONDUCTOR LENGTHS FIELD-
VERIFICATION.
3. REFERENCE DWG. E603 FOR CABLE SCHEDULE & SINGLE LINE DIAGRAM.
KEYED NOTES
NEW FEEDER CONNECTION: ELECTRICAL CONTRACTOR SHALL INSTALL NEW
LUGS IN EXISTING PANEL TO ACCEPT 2-#4 PER PHASE OR INSULATED
MECHANICAL SPLICES (BLACKBURN TYPE AMTD SERIES OR EQUIVALENT).
CONNECT FROM LINE SIDE OF MAIN BREAKER IN MCC7 STOR. PANEL.
CONTRACTOR SHALL EXIT STORAGE BUILDING WITH LB-FITTING THROUGH
SIDE OF BUILDING.
REFERENCE DRAWINGS
1. SINGLE LINE DIAGRAM REF. DRAWING E-603.
1/2" = 1'-0"E102
B CROSS SECTION DETAIL
N
PLAN NORTH
NEW 3-#4,1-#8G
CONNECT FROM
LINE SIDE OF MAIN
BREAKER IN MCC7
STOR. PANEL.
5 5 10 15 20 25 30 35 40 45 1/16" = 1'-0"
FEETSCALE
5 5 10 15 20 25 30 35 40 45 1/16" = 1'-0"
FEETSCALE
HOG SHED
CONCRETE WALL
EL
EC
TR
NOT USED
REPLACE BREAKERS CB3A AND CB3D WITH SQUARE D PART #LJA36400U33X. BREAKERS MUST HAVE LUGS
FOR 2 SETS OF 500 KCMIL PER PHASE. SEE DWG M-LM-84-E601 FOR ONE LINE DIAGRAM.
REPLACE CB3F WITH SQUARE D PART #LJA36600U33X. BREAKER MUST HAVE LUGS FOR 2 SETS OF 3-500
KCMIL PER PHASE. SEE DWG. M-LM-84-E600 FOR ONE LINE DIAGRAM.
REPLACE CB3I AND CB3N WITH SQUARE D PART #LJA36600U33X. BREAKERS MUST HAVE LUGS FOR 2 SETS
OF 500 KCMIL PER PHASE.
REPLACE CB3P AND CB3S WITH SQUARE D PART #LJA36600U33X. BREAKERS MUST HAVE LUGS FOR 2 SETS
OF 350 KCMIL PER PHASE. SEE DWG. M-LM-84-E600 FOR ONE LINE DIAGRAM.
MAIN SWITCHBOARD SECTION
KEYED NOTES:
D- 2 1 6 5 3 4 3
GENERAL NOTES:
1. BREAKER POSITIONS (SHOWN) SHALL REMAIN SO EXISTING FEEDER CABLES CAN BE RE-USED, LUG SIZES ON BREAKERS SHALL ACCOMMODATE THE EXISTING CABLES. CONTRACTOR SHALL PERFORM THIS WORK
DURING OUTAGE #1.
2. CONTRACTOR SHALL ADJUST BREAKER SETTINGS AS SPECIFIED BY THE GOVERNMENT.
NEW WORK SHOWN IN BOLD..
EXISTING WIREWAY TO REMAIN
CABLE # SETS # COND GND SERVICE FROM: TO: COMMENTS
P2000 2 3-350KCMIL EX 480V CB3P MAIN SWBD MCC3 EXISTING
P2001 2 3-350KCMIL EX 480V CB3S MAIN SWBD MCC3 EXISTING
P2002 2 3-350KCMIL EX 480V CB3I MAIN SWBD MCC5 EXISTING
P2003 2 3-350KCMIL EX 480V CB3N MAIN SWBD MCC5 EXISTING
P2004 3-500KCMIL EX 480V CB3A MAIN SWBD MCC2 EXISTING
P2004A 3-500KCMIL EX 480V CB3A MAIN SWBD MCC2 NEW
P2005 3-500KCMIL EX 480V CB3D MAIN SWBD MCC2 EXISTING
P2005A 3-500KCMIL EX 480V CB3D MAIN SWBD MCC2 NEW
P2006 2 3-350KCMIL EX 480V CB3F MAIN SWBD MCC1 EXISTING
CABLE SCHEDULE
NOTES
1.NOT USED
480 60
GRND WYE
1200 1200
3 3 3 3
2 43 05794691 APO
A N
SI
D
N O
/ E202M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B A
R R
Y R
.E
IK
M A
N N
,P E
B R
E
N A
N A
FI
LE
N U
M B
ER
:M
-L M
-8
LO
C
K S
N O
.2
R
IS
ER
D
IA
G
R A
M -M
A
IN
SW
IT
CH
BO
AR
D
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
B
M
IT
TE
D
B Y:
SI
ZE
C H
EC
K
ED
B
Y:
IS
SU
E D
A
TE
C O
N
TR
A C
T
SO
LI
C
IT
A
TI
O N
N O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
A M
PB
EL
L
PL
A
ZA
,S U
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
FI
R
ST
TI
TL
E
FI
LE
N A
M E:
US Army Corps
ST._LOUIS_DISTRICT
T:\Working\18073 - usace stl - l27 power dist upgrades\Drawings\M-LM-84-E600.dwg 10/07/19-14:28tlanuza
A N
S
ID
N O
/ E600M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
SI
N
G
LE
LI
N
E D
IA
G
R A
M S-
M A
IN
SW
B D
,M
CC
M
CC
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
CABLE # SETS # COND GND SERVICE FROM: TO: COMMENTS
P2004 3-500KCMIL EX 480V CB3A MAIN SWBD MCC2 EXISTING
P2004A 3-500KCMIL EX 480V CB3A MAIN SWBD MCC2 NEW, SEE NOTE 1
P2004 3-500KCMIL EX 480V CB3D MAIN SWBD MCC2 EXISTING
P2004B 3-500KCMIL EX 480V CB3D MAIN SWBD MCC2 NEW, SEE NOTE 1
MCC2 CABLE SCHEDULE
NOTES
2. EX=EXISTING
1. THESE CABLES WILL RUN AS PARALLEL FEEDERS TO P2004 AND P2005 RESPECTIVELY.
A N
S
ID
N O
/ E601M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
SI
N
G
LE
LI
N
E D
IA
G
R A
M -M
CC
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
A N
S
ID
N O
/ E603M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
SI
N
G
LE
LI
N
E D
IA
G
R A
M -M
CC
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
3K
100AF
100AT
LP-1B
H
IG
H M
AS
T
LI
G
H
TI
N G
PA
N
EL
3/C#2, W/GND,
11/4"C
L2
100AF
100AT
H
IG
H M
A
ST
LI
G
H
TI
N G
PA
N
EL
LP-2A
3/C#2, W/GND,
1 1/4"C
4A
L2
100AF
100AT
LP-4A
H
IG
H M
AS
T
LI
G
H
TI
N G
PA
N
EL
1I
3/C#2, W/GND,
1 1/4"CL2
100AF
100A
H
IG
H M
AS
T
LI
G
H
TI
N G
PA
N
EL
LP-3A
1 1/4"C
L2
3 3 3 4 34
A N
S
ID
N O
/ E604M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
SI
N
G
LE
LI
N
E D
IA
G
R A
M -M
AI
N
LO
CK
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
MCC3 FCBS
MCC3 CB3A MCC3 CB4C
REFERENCE PHOTO 1
REFERENCE PHOTO 2 REFERENCE PHOTO 3
MCC5 DISTRIBUTION PANEL
REFERENCE PHOTO 4
BREAKERS TO MCC7
REPLACE BUCKET CB4C AND MOVE TO
TOP OF MCC SO IT IS RIGHT NEXT TO
CB3BA.
SEE DWG. M-LM-84-E604 FOR SINGLE
LINE DIAGRAM SWAP NECESSARY
NAMEPLATES.
MOVE "MAIN LOCK I-WALL UPSTREAM
LEAF XFMR AND DRIVE" UNDER MCC
FEEDER TO ALLOW FOR SPACE FOR
CB4C ALL THE WAY TO THE TOP.
SWAP NECESSARY NAME PLATES.
REPLACE BUCKET CB3A IN PLACE. SEE DWG. M-LM-84-E604 FOR SINGLE LINE
DIAGRAM
REPLACE BREAKERS CB1BC, CB1SL,
CB1EL AND CB1QL IN PLACE. SEE
DWG. M-LM-84-E603 FOR SINGLE LINE
DIAGRAM
A N
S
ID
N O
/ E900M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
R
EF
ER
EN
C E
PH
O
TO
S
-O U
TA
G
E
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
5 6
B
C
D
E
7 8
F
.G
H
I
J
1 2 3
~2
40'-0"40'-0"40'-0"40'-0"40'-0"40'-0"40'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
~188'
~3 8'
EX
IS
TI
NG
FE
NC
E
METER POLE
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ ED100M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PO
ST
-O
UT
AG
E
D
EM
O
LI
TI
O N
AN
D
RE
LO
C
AT
IO
N
3/64" = 1'-0"
POST-OUTAGE 2 DEMOLITION
GENERAL NOTES
1. LENGTHS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE. CONTRACTOR IS
RESPONSIBLE FOR FIELD-VERIFICATION.
KEYED NOTES
1 REMOVE AND DISPOSE OF POSTS (MARKED IN DRAWING) AND COSTUMER-OWNED OVERHEAD
LINES. FILL ABANDONED POST HOLES WITH FLOWABLE FILL.
REFERENCE PHOTO 1
N
PLAN NORTH
1 1
2 AMEREN POLE REMOVAL: AMEREN TO REMOVE THREE POLES & POWER LINES OWNED BY
THEM. ELECTRICAL CONTRACTOR SHALL PAY COSTS TO AMEREN AS PART OF CONTRACT WITH
USACE.
REFERENCE PHOTO 2
2 2 2
METER POLE
METER POLE
EL
EC
TR
IC
AL
DE
M O
LI
TI
O N
40'-0"
EXISTING TRANSFORMER NAMEPLATE
A
7 8
ED101
EXISTING
POWER
BUILDING
EXISTING
DIESEL TANK
EXISTING
TRANSFORMER
40'-0"40'-0"
SEE DWG. M-LM-84-ED605
FOR DETAILED MCC-PB
DEMOLITION DRAWING
5' -9
7'-8"
EXISTING
SECURITY
CABINET
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ ED101M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PO
ST
-O
UT
AG
E
D
EM
O
LI
TI
O N
GENERAL NOTES
1. LENGTHS & DIMENSIONS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE.
CONTRACTOR IS RESPONSIBLE FOR FIELD-VERIFICATION.
KEYED NOTES
REFERENCE DRAWINGS
1/4" = 1'-0"ED101
2 EX. TRANSFORMER DEMOLITION
2 EXISTING TRANSFORMER TO BE REMOVED AND PROPERLY DISPOSED BY CONTRACTOR. REMOVE TRANSFORMER PAD, GROUT AND BOLLARDS. BACKFILL WITH FLOWABLE FILL, SEAL ANY ENTRIES INTO THE MANHOLE, AND
REPAIR ASPHALT PER DETAIL IN CIVIL DWG. C101.
3/16" = 1'-0"
POST-OUTAGE 2 DEMOLITION & RELOCATION
4160 V DELTA
480Y/277 V
1000 KVA
TOTAL APPROX. WEIGHT 8180 LBS
3 REMOVE POLE, GUY-WIRES, RISER CONDUITS & OVERHEAD CONDUCTORS. CONTRACTOR SHALL USE FLOWABLE
FILL FOR POLE, BACKFILL, AND REPAIR ALL ASPHALT PER CIVIL DWG. C101.
N
PLAN NORTH
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10 12 14 3/16" = 1'-0"
FEETSCALE
1. CABLE RISER DIAGRAM REF. DRAWING E-205. SINGLE LINE DIAGRAM REF. DRAWING E-604.
EL
EC
TR
IC
AL
DE
M O
LI
TI
O N
NOT USED.
B
4 7 82 3
40'-0"40'-0"40'-0"40'-0"40'-0"40'-0"
'-0
'-0
EXISTING
MANHOLE
NO.2
EXISTING
MANHOLE
NO.1
AA
EXISTING
DIESEL TANK
E103
NEW
POLYMER
CONCRETE
QUAZITE BOX
E103
E103
REF. DWG M-LM-84-E104
FOR DETAIL OF THIS AREA
EXISTING
TRANSFORMER
EXISTING
PHONE BOX
NEW UNDERGROUND DUCTBANK
EXISTING SHED
TO BE
DEMOLISHED
BY OWNER
REF. CIVIL DWG.
M-LM-84/C101
'-8
4'-0"
~6' FROM FENCE
EXISTING UNDERGROUND DUCTBANK
~7
EXISTING CURB
1' -8
2' -4
0' - 0"
3000 PSI CONCRETE
(DYED RED)
1'-8"
4/0 BARE COPPER CONDUCTOR.
RUN ENTIRE LENGTH OF
DUCTBANK BONDED TO
GROUND GRID AT BOTH ENDS
4 #4 REBAR
WITH 4 CROSS
TIES 36" ON CENTER
EXISTING
UNDERGROUND
DUCTBANK
MIN. 6"
~4'-7"
GROUND LEVEL
0' - 0"
AAA
2' -0
EXISTING
PHONE BOX
EXISTING
MANHOLE
NO.2
EXISTING
DUCTBANK
3' -6
~6
40'-0"
ASPHALT
NEW POLYMER CONCRETE QUAZITE BOX
REF. DWG M-LM-84/E200 #2 FOR BOX DETAIL
NEW CONDUITS SHALL BE
INSTALLED DIRECTLY ON TOP
OF EXISTING DUCTBANK
EXISTING
FENCE
2' -4
GROUND LEVEL
0' - 0"
EXISTING FENCE EXISTING SHED TO
BE DEMOLISHED
BY OWNER
NEW
POLYMER
CONCRETE
QUAZITE BOX
(2) 4" PVC SCHEDULE 40
IN CONCRETE
ENCASEMENT
(2) 4" PVC SCHEDULE 40 IN
CONCRETE ENCASEMENT
2' -4
REF. CIVIL
DWG.
M-LM-84/C101
2' -4
EXISTING
CURB
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E103M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PL
AN
-I N
CO
M
IN
G
U
TI
LI
TY
3/32" = 1'-0"
SITE PLAN - INCOMING UTILITY
GENERAL NOTES
1. REFER TO CIVIL DWG. M-LM-84/C101.
2. LENGTHS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE.
CONTRACTOR IS RESPONSIBLE FOR FIELD-VERIFICATION.
3. CONTRACTOR SHALL TEMPORARILY RESTORE ALL PERIMETER FENCING
AT THE END OF EACH WORKING DAY.
KEYED NOTES
1 CONCRETE BOX: 48" x 48" PG STYLE POLYMER CONCRETE BOX.
REF. DWG E200.
REFERENCE DRAWINGS
1. CABLE RISER DIAGRAM REF. DRAWING E-205. SINGLE LINE
DIAGRAM REF. DRAWING E-604.
N
PLAN NORTH
1/2" = 1'-0"E103
2 NEW TRENCH DETAIL
1/4" = 1'-0"E103
3 DETAIL LOOKING WEST
1/4" = 1'-0"E103
4 DETAIL LOOKING SOUTH
5 5 10 15 20 25 30 3/32" = 1'-0"
FEETSCALE
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
2 SECURITY FENCE: FENCE SHALL REMAIN. CONTRACTOR TO
LEAVE IN PLACE OR RESTORE AFTER CONSTRUCTION.
EL
EC
TR
7 8 40'-0" 40'-0"
EXISTING
POWER
BUILDING
EXISTING
GENERATOR
CT CAB
NEW MCC-PB
SECTIONS
EXISTING ATS
NEW
TRANSFORMER
BY AMEREN
REF. DWG E200,
DETAIL #1 FOR
TRANSFORMER
PAD DETAILS
M
E104
EXISTING
DIESEL TANK
EXISTING
MANHOLE
NO.1
EXISTING
TRANSFORMER
4'-5"
VENT
EXISTING FENCE
E104
EXISTING
SECURITY
PANEL AT
NEW
LOCATION.
SEE DWG.
DETAIL 4, THIS
DRAWING
FOR
RELOCATION
INFO.
EXISTING
CONTROL
PANEL
(ABOVE)
CONCRETE-FILLED
4" IRON PIPES
3' DEEP, 5' TALL
E104
EXISTING
UNDERGROUND
DUCTBANK
NEW UNDERGROUND DUCTBANK
NEW SECONDARY
CONDUITS
ENCASED IN RED-
DYED CONCRETE
'-2
EXISTING 4160V
RISER POLE
1' -0
2'-8"
E104
A
EXISTING
GENERATOR
NEW METER
NEW
TRANSFORMER
BY AMEREN
(4) 3" PVC SCH. 40
IN RED-DYED CONCRETE
ENCASEMENT
(4) 3" RGS (ELBOWS & VERTICALS)
(4) 3" PVC SCH. 40 IN RED-DYED
CONCRETE ENCASEMENT
(4) 3" RGS (FOR ELBOWS
AND VERTICALS)
(4) 3" RGS
3' -0
EXISTING
UNDERGROUND
DUCTBANK
MCC-PB
(1) 1" RGS
A
NEW 1G SPLICE BOX
TWPR SHALL BE
BUTT-SPLICED WITH
HEAT SHRINK WRAP.
3/4"
1TWPR
3/C#12
EXISTING
SECURITY
PANEL AT
NEW
LOCATION.
SEE DWG.
DETAIL 4, THIS
DRAWING
FOR
RELOCATION
INFO.
(4) 3" RGS (ELBOWS &
VERTICALS)
(4) 3" PVC SCH.40
ENCASED IN RED-
DYED CONCRETE
(4) 3"
RGS
EXISTING
UNDERGROUND
DUCTBANK
NEW CT
CABINET 10
'-2
2' -0
NEW MCB
A
EXISTING
SECURITY
CABINET
(SALVAGE)
3/4"
4-TWPR
1" 9/C#12
3/4" 3/C#12
3/4"
4-TWP
1" 3/C#12
2-CAT5
1-TWPR
3/4"
4-TWPR
3/4
1-TWP CT CABINET (BY CONTRACTOR
PER AMEREN REQUIREMENTS)
METER (BY AMEREN)
METER BASE (BY CONTRACTOR
PER AMEREN REQUIREMENTS)
CTs (BY AMEREN)
5' -0
FISNISHED
GRADE
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E104M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PL
AN
-P O
W
ER
BU
IL
DI
N
G
1/4" = 1'-0"
NEW TRANSFORMER AREA DETAIL
GENERAL NOTES
1. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
UNDERGROUND LOCATES IN THIS AREA PRIOR TO DIGGING.
2. LENGTHS IDENTIFIED IN THIS DRAWING ARE APPROXIMATE. CONTRACTOR IS
RESPONSIBLE FOR FIELD-VERIFICATION.
KEYED NOTES
REFERENCE DRAWINGS
N
PLAN NORTH
1/4" = 1'-0"E104
3 EXISTING POWER BUILDING ELEVATION WEST
1 NEW CHAINLINK FENCING: FURNISHED BY CONTRACTOR TO MATCH EXISTING, W/ 2-4 SWING GATES.
1/4" = 1'-0"E104
2 EX. SECURITY PANEL AT NEW LOCATION
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
1. CABLE RISER DIAGRAM REF. DRAWING E-205. SINGLE LINE DIAGRAM REF. DRAWING E-604.
1/4" = 1'-0"E104
4 EX. SECURITY PANEL RELOCATION
EL
EC
TR
IC
AL
SECURITY PANEL: RELOCATE EXISTING SECURITY PANEL TO ALLOW NEW MCB TO FULLY OPEN.
MOVE BOTTOM OF PANEL APROX. 60" UP. CONFIRM LOCATION IN FIELD. RECONNECT
ALL EXISTING FEEDERS. REF. DWG. E104, DETAIL #2 FOR NEW LOCATION.
TRANSFORMER LOCATION: LOCATION OF NEW TRANSFORMER PAD SHOULD BE
REFERENCED FROM LOCATION OF EXISTING DUCTBANK.
1/4" = 1'-0"E104
5 METER AND CT CABINET ELEVATION
4 73
AA
40'-0"40'-0"40'-0"40'-0"
'-0
EXISTING
MANHOLE
NO.1
NEW
TRANSFORMER
BY AMEREN
NEW
POLYMER
CONCRETE
QUAZITE BOX
EXISTING
MANHOLE
NO.2
E105
E105
EXISTING SHED
GT
NEW UNDERGROUND DUCTBANK
3/4", 8' LENGTH
GROUNDING ROD
NEW FENCE
CONNECTED TO
GROUNDING RING
E105
EXISTING
UNDERGROUND
DUCTBANK MCCPB ATS
4/0 BARE
EXISTING
8-3/0 EGC
4-3/0 EGC NEW MCB
CT CABINET
4/0 GND
TA
A
NEW
TRANSFORMER
BY AMEREN
NEW
UNDERGROUND
DUCTBANK
FOR PRIMARY
FEEDER
NEW CT
CABINET
(2) 4" W/ (6) 350 KCMIL,
& 1-3/0G EACH
(4) 3" W/ (4)
350 KCMIL
ALL BONDING CONDUCTORS
SHALL BE BONDED TOGETHER
AND BONDED TO THE
TRANSFORMER GROUNDING PAD.
BARE 4/0 IN NEW TRENCH
4/0 BARE
COPPER IN
1" RGS
EXISTING
UNDERGROUND
DUCTBANK
GND RODS
BARE 4/0 GEC
4/0 BARE COPPER
GEC IN TRENCH
4/0 BARE
COPPER
4-3/0 EGC IN RGS
(1-3/0 XHHW-2 IN
EACH CONDUIT)
NEW CT
CABINET
NEW METER
EXISTING
CONTROL
PANEL
(ABOVE)
EXISTING
UNDERGROUND
VAULT
INSIDE BUILDING
OUTSIDE BUILDING
INSIDE BUILDING
NEW MCCPB
INSIDE
BUILDING
1-3/0 XHHW-2 IN EACH CONDUIT (INSIDE BUILDING)
4/0 BARE COPPER IN
1" RGS
EXISTING
ATS
4/0 BARE COPPER
THROUGH WALL
EXISTING
8-3/0 EGC
1-4/0 EGC
INSIDE
BUILDING
1' -0
NAME TYPE DESCRIPTION
CABLE TO CABLE CONNECTIONS
CABLE TO BUS CONNECTIONS
PLAN SYMBOL
GROUNDING LEGEND
HORIZONTAL TEE USED FOR CABLE
SIZE RUNS
#4 - 1000 KCMIL
VERTICAL STEEL
SURFACE
USED FOR CABLE
SIZE
#6 - #250 KCMIL
CABLE TO REBAR CONNECTS TO REBAR
SIZES 3 THRU 18.
CABLE SIZE USED,
#6 - 4/0 AWG
CABLE TO REBAR CONNECTIONS
CABLE TO GROUND
ROD
USED WITH
GROUND ROD
SIZES 1/2", 5/8" OR
3/4"
TA
GT
RR
VS
NEW
TRANSFORMER
BY AMEREN
APPROVED
MECHANICAL
GROUNDING
CLAMPS
#6 BARE
COPPER
TO NEW
GROUNDING
RING
TO NEW
GROUNDING
RING
US Army Corps of Engineers ®
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E105M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
PL
AN
-G R
O U
ND
IN
G -I
N
CO
M
IN
G U
TI
LI
TY
1/8" = 1'-0"
INCOMING UTILITY - GROUNDING
1/4" = 1'-0"E105
2 GROUNDING ELEVATION 1
1/4" = 1'-0"E105
3 GROUNDING ELEVATION 2
1 GROUND CONDUCTOR BONDED TO
TRANSFORMER GROUND PAD.
2 GROUND CONDUCTOR BONDED TO GROUND BAR
IN CT CABINET, MCB, ATS & MCC-PB.
KEYED NOTES
3 BOND 4/0 BARE CONDUCTOR TO BUILDING STEEL
ABOVE. BOND W/EXOTHERMIC WELD.
EX. POWER BUILDING
5 5 10 15 20 1/8" = 1'-0"
FEETSCALE
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
N
PLAN NORTH
1/4" = 1'-0"E105
5 FENCE GROUNDING DETAIL
4 ALL BONDING CONDUCTORS SHALL BE BONDED
TOGETHER AND BONDED TO TRANSFORMER
GROUNDING PAD.
EL
EC
TR
IC
AL
5 FURNISH BONDING JUMPER BETWEEN NEUTRAL
AND GROUND IN NEW MAIN CIRCUIT BREAKER AND
CT CABINET.
1. ALL GROUNDING CONDUCTORS SHALL BE BARE
COPPER 4/0 UNLESS OTHERWISE NOTED.
GENERAL NOTES
DRAWING
NUMBER
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
BY
SU
BM
IT
TE
D
BY
SI
ZE
C H
EC
KE
D
BY
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
A
B C D E F G H
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
ST._LOUIS_DISTRICT
/ E200M-LM-84
PO
W
ER
DI
ST
RI
BU
TI
O N
UP
G
RA
D
ES
LO
W
ER
M
IS
SI
SS
IP
PI
R
IV
ER
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
C D
G
EN
G
IN
EE
R
IN
G
,I N
C
C
AM
PB
EL
L
PL
AZ
A, SU
IT
E
3A
SA
IN
T
LO
U
IS
,M
O
TM
L
TM
L
BA
R
R Y
R .E
IK
M
AN
N
,P E
BR
E
N A
N A
FI
LE
N U
M
BE
R :M
-L M
-8
FI
R
ST
TI
TL
E
FI
LE
N
AM
E:
LO
CK
S
NO
.2
EL
EV
AT
IO
N S
AN
D
D
ET
AI
LS
1 1/2" = 1'-0"
1 AMEREN TRANSFORMER DETAIL
1 1/2" = 1'-0"
2 QUAZITE BOX
E104
E103
EL
EC
TR
IC
AL
• COVER: HUBBEL PART NO. PG4848HH00** OR
APPROVED EQUAL
• BOX: HUBBEL PART NO. PG4848BA48 OR APPROVED
EQUAL
1A
OUTGOING SECTION FOR
AUTOMATIC
TRANSFER SWITCH
EXISTING COMMUNICATIONS CABINET
EXISTING
AUTO-TRANSFER
SWITCH
TO REMAIN
MCC-PB
P0010,11,12,13 P0014,15,16,17 P0018-22
EXISTING
UNDERGROUND
CABLE
VAULT
4 4 4
EXISTING WIREWAY
(REMAIN)
EXISTING
PPA
TO REMAINPPA
NEW
MAIN
CIRCUIT
BREAKER
(MCB)
MCB REQUIREMENTS
· VOLTS: 480/277
· AMPS/POLES: 1200A/3, LSIG TRIP ADJUSTMENTS
· SCCR: 65KA INCOMING BOTTOM FEED, LUGS FOR 4-350 KCMIL COPPER PER
PHASE
· INCOMING: BOTTOM/BACK, LUGS FOR 4-350KCMIL COPPER PER PHASE, 4-1/0
NEUTRAL.
· OUTGOING: TOP, LUGS FOR 4-350 KCMIL COPPER PER PHASE, 4-1/0 NEUTRAL
· GROUND BAR: YES
· METERING: INTEGRAL, DIGITAL DISPLAY; VOLTS, AMPS, KVA, KVAD, POWER
FACTOR ARE MINIMUM PARAMETERS REQUIRED.
· NEMA/UL SPECS: NEMA 1 ENCLOSURE, RATED AS SERVICE ENTRANCE
EQUIPMENT.
· TRIP UNIT: ELECTRONIC LSIG, WITH ARC-FLASH REDUCTION SWITCH, WHICH
CHANGES INSTANT TRIP SETTINGS TO MINIMUM. SWITCHES SHALL BE OF THE
SELECTOR SWITCH TYPE ACCESSIBLE FROM DEAD FRONT COVERS. SWITCHES
SHALL HAVE ENGRAVED NAMEPLATES, AND LOCKING COVERS. SWITCHES SHALL
BE ILLUMINATED AMBER WHEN IN ARC FLASH REDUCTION MODE. BREAKERS
SHALL HAVE ZONE-SELECTIVE INTERLOCKING (REF. NOTE 8 THIS DWG.).
· MOUNTING: WALL
· ACCESSIBILITY: ALL SETTINGS & ARC-FLASH SWITCH SHALL BE ACCESSIBLE
FROM DEAD FRONT WITHOUT OPENING COVERS. BREAKERS SHALL HAVE
EXTERNAL MEANS FOR LOCKING IN THE OPEN OR OFF POSITION.
NEW EXISTING
1H
1T
2A
2H
2O
2Q
3A
3E
3G
3I
3K
3O
3Q
MAIN LUGS
(4) 3" CONDUITS
NEW P0003A, 4B, 5B, 6B TO NEW
MAIN CIRCUIT BREAKER
EXISTING 1" WITH
4-2PR CABLES TO
EXISTING SECURITY
CABINET (~30FT)
EXISTING 2" WITH FIBER & 120V
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPD - 160kA
FLOOD TRLRS.
PPA
COMFORT ST.
3M
WELDING REC.
FUTURE
MAINTENANCE
BUILDING
LIGHTING XFMR
2J
LOCK FEEDER
FCB NO.1
1200A
LOCK FEEDER
FCB NO.2
1200A
REFERENCE PHOTO 1
6 6
(4) 3" CONDUITS
NEW P0003B, 4B, 5B,
6B FROM MCC PB
(2) 4" CONDUITS THROUGH WALL.
NEW P0003A, 4A, 5A, 6A TO
NEW TRANSFORMER
OUTSIDEP0007-9 (GENERATOR) TO REMAIN (NO CHANGE)
P0003A-6A (TO NEW TRANSFORMER)
INCOMING SECTION
(1) 1" 1PR18SH
TO MCC-PB MAIN FCBs
(1) 1" 1PR18SH
TO MCC-PB
MAIN FCBs
8 8
1' -0
KEYED NOTES:
GENERAL NOTES:
1. OUTAGE WORK: CONTRACTOR SHALL PERFORM PRE-OUTAGE
INSTALLATION WORK TO THE MAXIMUM EXTENT POSSIBLE IN ORDER TO
MINIMIZE OUTAGE TIME.
2. CONDUIT PENETRATIONS: ALL NEW CONDUIT PENETRATIONS INTO
EQUIPMENT SHALL USE SEALING FITTINGS.
REPLACE MCC-PB: ATS TO REMAIN IN PLACE. NEW MCC SHALL HAVE
CONFIGURATION AS SHOWN IN THIS DRAWING.
EXISTING FIBER OPTIC/CONTROL CABLES: RE-CONNECT 3-24STD
FIBER CABLES, 7 #12 CABLES PREVIOUSLY STOWED IN CABLE VAULT
BELOW MCC-PB, TO COMMUNICATIONS CABINET. RE-CONNECT
4-TWISTED PAIR CABLES TO CABINET.
EXISTING CONDUCTORS: (4) SETS OF 350 KCMIL TO BE PULLED BACK
TO WIREWAY AND RETERMINATED TO NEW LUGS.
EXISTING FEEDERS: SHALL BE DISCONNECTED & RECONNECTED TO
NEW MCC-PB.
NEW FEEDERS: CONTRACTOR SHALL FURNISH NEW FEEDERS
(P0003,4,5,6) FROM NEW MAIN CIRCUIT BREAKER TO ATS. FEEDERS
SHALL BE INSTALLED IN EXISTING WIREWAYS ABOVE ATS. FEEDERS &
CONDUITS SHALL BE ROUTED NEAR CEILING & OVER TO THE NEW
MAIN CIRCUIT BREAKERS ON NORTH WALL OF GENERATOR BUILDING.
EXTEND CABLES: EXTEND CABLES ~5 FEET FOR BOTH 1200A
BREAKERS USING INSULATED MECHANICAL CONNECTORS (NSI
INDUSTRIES, POLARIS ISR SERIES IN LINE TYPE OR EQUIVALENT.) USE
SAME CABLE SIZE. SPLICES INSTALLED AT VAULT BELOW MCC.
NAMEPLATES: SHALL BE FURNISHED BY CONTRACTOR. NAMEPLATES
SHALL BE ENGRAVED BLACK LETTERING IN WHITE BACKGROUND 1
4"
HEIGHT, WITH CUBICLE NUMBER.
ZONE SELECTIVE INTERLOCKING: BREAKERS SHALL HAVE ZONE
SELECTIVE INTERLOCKING CAPABILITIES. ZONE INTERLOCKING SHALL
PERMIT ELECTRONIC TRIP DEVICES TO SIGNAL EACH OTHER VIA LOW
VOLTAGE SIGNALS TO CLEAR A FAULT VIA THE NEAREST UPSTREAM
CIRCUIT BREAKER WITHOUT INTENTIONAL TIME DELAY.
INTERLOCKING FUNCTION SHALL NOT SACRIFICE COORDINATION
WITH UPSTREAM DEVICES.
MCC REQUIREMENTS
· VOLTS/AMPS: 480/277/1200A
· HORIZONTAL: 1200A BUS
· VERTICAL: BUS 600A
· MAINS: 1200 MLO
· SPD: INTERNAL, 160KA RATED, INTEGRAL FEEDER CIRCUIT BREAKER
· SCCR: 65KA
· INCOMING: TOP FEED, LUGS FOR 4-350 KCMIL COPPER PER PHASE
· OUTGOING: BOTTOM FEED
· GROUND BAR: YES
· METERING: NOT REQUIRED
· NEMA/UL SPECS: NEMA 1G
· DIMENSIONS: MATCH EXISTING MCC BEING REPLACED IN SAME LOCATION.
· FEEDER BREAKERS: 480V, 65KA, ADJUSTABLE INSTANTANEOUS TRIP.
REFERENCE DWGS.
1. DEMOLITION: M-LM-84-ED205
2. SINGLE LINE DIAGRAM: M-LM-84-E604
CABLE # SETS # COND GND SERV. FROM: TO: COMMENTS
EX ATS 4 3-350KCMIL W/GND EXISTING 480V ATS OUTPUT MCC-PB EXISTING; REUSE W/NEW MCC P0003A-6A 4 3-350KCMIL, 1/0 N 480V NEW AMEREN XFMR NEW MCB NEW; VIA CT CAB. & NEW MCB
P0003B-6B 4 3-350KCMIL 3/0 480V NEW MCB ATS NEW; VIA CT CAB. & NEW MCB
P0010-13 4 3-350KCMIL W/GND EXISTING 480V CB1A MCC PB MAIN SWBD EXISTING; EXTEND & REUSE
P0014-17 4 3-350KCMIL W/GND EXISTING 480V CB2A MCC PB MAIN SWBD EXISTING; EXTEND & REUSE
P0018 3-#1 W/GND EXISTING 480V CB3BB MCC PB MCCPB WR EXISTING; REUSE
P0019 3-350KCMIL W/GND EXISTING 480V CB3D MCC PB LP-SG XFMR EXISTING; REUSE
P0020 3-#1/0 W/GND EXISTING 480V CB3BA MCC PB CS XFMR EXISTING; REUSE
P0021 3-#2 W/GND EXISTING 480V CB33E MCC PB PPA EXISTING; REUSE
P0022 3-#4/0 W/GND EXISTING 480V CB3CA MCC PB FLOOD TRAIL. EXISTING; REUSE
P0001C 3-#4/0 W/GND EXISTING 24VDC NEW MCB CB1A MCC PB NEW; INTERLOCK
P0002C 3-#4/0 W/GND EXISTING 24VDC NEW MCB CB2A MCC PB NEW; INTERLOCK
MCCPB CABLE SCHEDULE
A N
S
ID
N O
/ E205M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
R
IS
EE
R
D
IA
G R
A M
-G
EN
ER
A
TO
R
B U
IL
D
IN
G
M
CC
PB
EL
EC
TR
IC
AL
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
OUTGOING SECTION FOR
AUTOMATIC
TRANSFER SWITCH
EXISTING COMMUNICATIONS CABINET
KEYED NOTES:
GENERAL NOTES:
1. OUTAGE WORK: CONTRACTOR SHALL PERFORM PRE-OUTAGE INSTALLATION WORK TO THE
MAXIMUM EXTENT POSSIBLE IN ORDER TO MINIMIZE OUTAGE TIME. ALL OUTAGE WORK TO BE
PERFORMED DURING SCHEDULED OUTAGE #2.
REPLACE MCC-PB: ATS TO REMAIN IN PLACE. NEW MCC SHALL HAVE CONFIGURATION AS SHOWN IN
DRAWING M-LM-84-E205 - RISER MCCPB.
EXISTING FIBER OPTIC/CONTROL CABLES: DISCONNECT 3-24STD FIBER CABLES, 7 #12 CABLES
FROM COMMUNICATIONS CABINET & STOW IN CABLE VAULT BELOW MCC-PB. DISCONNECT
4-TWISTED PAIR CABLES FROM SECURITY CABINET, PULL BACK & STOW IN CABLE VAULT.
EXISTING CONDUCTORS: (4) SETS OF 350 KCMIL TO BE RE-USED.
EXISTING FEEDERS: SHALL BE DISCONNECTED & RECONNECTED TO NEW MCC-PB (SEE DWG.
M-LM-84-E205 - RISER MCCPB) FOR NEW MCC CONFIGURATION.
OLD FEEDERS: ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING FEEDER CONDUCTORS
(EXISTING P0003,4,5,6) SOURCED FROM THE OWNERS EXISTING TRANSFORMER. ABANDON
CONDUCTORS IN CABLE VAULT BELOW ATS & MCC-PB. CONDUCTORS TO BE REMOVED AS PART OF
POST OUTAGE DEMO WORK.
TO EXISTING
SECURITY
CABINET (~30
FT.)
EXISTING
AUTO-TRANSFER
SWITCH
TO REMAIN
P0010,11,12,13 P0014,15,16,17 P0018-22
EXISTING
CABLE
VAULT
4 4 4
EXISTING 2"
WITH FIBER & 120V CABLES
EXISTING 1"
WITH 4-2PR CABLES
EXISTING WIREWAY
(REMAIN)
EXISTING
PPA
TO REMAIN
PPA
REFERENCE PHOTO NO.3
REFERENCE PHOTO NO.2
REFERENCE PHOTO NO.1
LEGEND:
INDICATES DEMOLITION
P0007-9 (TO GENERATOR, TO REMAIN NO CHANGE)
CABLE # SETS # COND GND SERV. FROM: TO: COMMENTS
EX ATS 4 3-350KCMIL W/GND EXISTING 480V ATS OUTPUT MCC-PB EXISTING; DISC. & REUSE W/NEW MCC P0003-6 4 3-350KCMIL 3/0 480V EXISTING XFMR ATS EXISTING; TO EXISTING XFMR; REMOVE P0010-13 4 3-350KCMIL W/GND EXISTING 480V CB1A MCC PB MAIN SWBD EXISTING; DISC. & REUSE
P0014-17 4 3-350KCMIL W/GND EXISTING 480V CB2A MCC PB MAIN SWBD EXISTING; DISC. & REUSE
P0018 3-#1 W/GND EXISTING 480V CB3BB MCC PB MCCPB WR EXISTING; DISC. & REUSE
P0019 3-350KCMIL W/GND EXISTING 480V CB3D MCC PB LP-SG XFMR EXISTING; DISC. & REUSE
P0020 3-#1/0 W/GND EXISTING 480V CB3BA MCC PB CS XFMR EXISTING; DISC. & REUSE
P0021 3-#2 W/GND EXISTING 480V CB33E MCC PB PPA EXISTING; DISC. & REUSE
P0022 3-#4/0 W/GND EXISTING 480V CB3CA MCC PB FLOOD TRAIL. EXISTING; DISC. & REUSE
MCCPB DEMOLITION CABLE SCHEDULE
P0003-6-EX (TO EXISTING TRANSFORMER, REMOVE)
A N
S
ID
N O
/ ED205M-LM-84
PO
W
ER
D
IS
TR
IB
U
TI
O
N U
PG
RA
DE
S
LO
W
ER
M
IS
SI
SS
IP
PI
RI
VE
R
SA
IN
T
LO
U
IS
D
IS
TR
IC
T
ST
.L O
U
IS
,M
IS
SO
U
R I6
-2
TM
L
TM
L
B
AR
R Y
R .E
IK
M
A N
N ,P
E
BR
E
N A
N A
FI
LE
N U
M B
E R
:M -L
M -8
LO
C
K S
N O
.2
R
IS
ER
D
IA
G
R A
M -G
EN
ER
A
TO
R B
U
IL
D
IN
G M
CC
PB
EL
EC
TR
IC
A L
D
EM
O
LI
TI
O
N
DRAWING
NUMBER
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W
N
BY
D
ES
IG
N
E D
BY
S U
B M
IT
TE
D
BY
S
IZ
E:
C H
E C
K
ED
BY
IS
S
U E
D
AT
E:
C O
N
TR
AC
T
S O
LI
C
IT
A
TI
O
N N
O
A
B C D E F G H
D A
TE
M
A R
K D
ES
C
R
IP
TI
O
N
C D
G E
N G
IN
E
E R
IN
G
,I N
C
C
A M
P B
E
LL
P
LA
ZA
,S
U
IT
E 3A
S A
IN
T
LO
U
IS
,M
O
FI
R
S T
TI
TL
E
FI
LE
N
AM
E:
US Army Corps
| M-LM-84 - G001 SEALED |
| M-LM-84 - G002 SEALED |
| M-LM-84 -G003 SEALED |
| M-LM-84 -G100 SEALED |
| M-LM-84 - E101 SEALED |
| M-LM-84 - E102 SEALED |
| M-LM-84-E202 SEALED |
| M-LM-84-E600 SEALED |
| M-LM-84-E601 SEALED |
| M-LM-84-E603 SEALED |
| M-LM-84-E604 SEALED |
| M-LM-84-E900 SEALED |
| M-LM-84 -C101 SEALED |
| M-LM-84 - ED100 SEALED |
| M-LM-84 - ED101 SEALED |
| M-LM-84 - E103 SEALED |
| M-LM-84 - E104 SEALED |
| M-LM-84 - E105 SEALED |
| M-LM-84 - E200 SEALED |
| M-LM-84-E205 SEALED |
| M-LM-84-ED605 SEALED |