ARRA2-Renovation of Building 2 Drawings.pdf

PDF 424 KB Posted

Attached to
RECOVERY: Renovation of Building #2 at Coyote Valley Dam, Lake Mendocino, CA Project No 4230
Solicitation number
W912P7-10-B-0007
Issued by

About this file

Drawings

View the file

Other files

File Type Posted
Bid Results Mar 31 2010.pdf PDF
Amendment 1 to Solicitation.pdf PDF
Questions and Answers.pdf PDF
Bid Bond form.pdf PDF
Questions and Answers.doc DOC document
WalkThruAttend.pdf PDF
61-43-17 Sheet 10D.PDF PDF
61-43-17 Sheet 11B.PDF PDF
Scope of Work CVD Bld 2 Renov - ARRA 23.pdf PDF
W912P7-10-B-0007.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARK HEADQUARTERS

SEE LOCATION MAP

La ke

M en do ci no

To Hopland

To Willits

Ukiah

Calpella

The Forks

GENERAL NOTES

1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO

STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE CORPS OF

ANY DISCREPANCIES.

2. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE

ALERT (USA) AT LEAST 48 HOURS IN ADVANCE OF ANY EXCAVATION

(1-800-642-2444).

3. CONTRACTOR SHALL PROVIDE ADEQUATE DUST CONTROL AT

ALL TIMES AS REQUIRED BY ARMY CORPS REPRESENTATIVES AND

THE BAAQMD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

COSTS DUE TO AIR QUALITY VIOLATIONS. CONTRACTOR SHALL

PROVIDE NOISE CONTROL AT ALL TIMES.

4. CONTRACTOR SHALL EXERCISE ALL NECESSARY CAUTION TO

AVOID DAMAGE TO ANY EXISTING TREES, LANDSCAPING,

IRRIGATION SYSTEMS, FENCES, BOLLARDS, OR SURFACE

IMPROVEMENTS, OR TO ANY EXISTING DRAINAGE STRUCTURES,

WATER STRUCTURES, SEWER CLEANOUTS, OR JUNCTION BOXES FOR

UNDERGROUND ELECTRIC, TELEPHONE, OR STORM SEWER,

SANITARY SEWER, WATER LINE, AND UNDERGROUND UTILITIES,

WHICH ARE TO REMAIN IN PLACE, AND SHALL BEAR FULL

RESPONSIBILITY FOR ANY DAMAGE.

5. EXISTING UTILITY LINES WHICH ARE KNOWN TO THE ENGINEER

ARE SHOWN FOR INFORMATION ONLY. CONTRACTOR SHALL

CONDUCT NECESSARY POTHOLE OPERATION TO IDENTIFY

UNDERGROUND UTILITIES IN ADVANCE OF TRENCHING AND SHALL

BE RESPONSIBLE FOR THE VERIFICATION OF ALL EXISTING UTILITIES

IN THE FIELD AND EXERCISE ALL NECESSARY CAUTION TO AVOID

DAMAGE TO ANY EXISTING UTILITY LINE OR FACILITIES TO REMAIN

IN PLACE, WHETHER OR NOT SUCH LINES OR FACILITIES ARE SHOWN

ON THESE PLANS, AND SHALL BEAR THE FULL RESPONSIBILITY FOR

ANY DAMAGE THERETO. NO WARRANTY IS GIVEN AS TO THE

ACCURACY OF EXISTING UTILITY INFORMATION.

6. CONTRACTOR SHALL RESTORE OR REPLACE ANY DAMAGED

MONUMENTS RESULTING FROM HIS OPERATION AND SHALL BEAR

ALL COSTS OF SUCH REPLACEMENT.

SYMBOL DESCRIPTION DATE APPR.

MENDOCINO COUNTY CALIFORNIA

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

TITLE SHEET

VICINITY &LOCATION MAPS

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 1 OF 6

Redwood Valley

AMERICAN RECOVERY & REINVESTMENT ACT

BUILDING #2 RENOVATION

COYOTE VALLEY DAM/LAKE MENDOCINO

NOT TO SCALE

VICINITY MAP

LAKE M

ENDOCINO DRIVE

SCALE: 1:400

LOCATION MAP

STAGING AREA

PA

RK

H

EA

D Q

U A

RT

ER

S

BU

IL

D

IN

G

MAINTENANCE

BUILDING

BU

IL

D

IN

G

SCHEDULE OF DRAWINGS

SHEET NO. TITLE OF DRAWING

1 TITLE SHEET - VICINITY & LOCATION MAPS

2 GENERAL FLOOR PLAN

3 FRAMING PLAN

4 ELECTRICAL PLAN

5 HEATING, VENTILATION & AIR CONDITIONING PLAN

6 PLUMBING PLAN

N

N

SYMBOL DESCRIPTION DATE APPR.

MENDOCINO COUNTY CALIFORNIA

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

GENERAL FLOOR PLAN

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 2 OF 6

5'

3'

3' 2'-6"

2'-6.2"

3'-3" 17'-10" 15'-3" 12'-1" 20'-1"

20'-7"12'-4.5"7'-8"11'7'-9"9'-1.5"

3'

4'-6"

4'-6"

R1'-6"

2'-2"

2'-4.2"

1'

2'-4"

2'2'-9"

1'-10"

4'-9"

11'-9"

3'-11.5"3'-6"SIZE TO FIT EXISTING

ELECTRICAL BOX

4'

5'

12'

8'

68'-6"

32'-4"

10'-10"

15'-6"

20'-2"

39'-6"

15'-6.5"

9'-9"

15'-6"

5'

2'

2'-8"

3'

ADA STALLS

(COMPLIANT

TO ADAAG)

3'-8"

W

W

W

W

W

W

W

W

W

D

D

D

D

D

D

D

D

D

D

D

D

D

DOOR SCHEDULE

CALL

OUT TYPE DESCRIPTION

DIMENSIONS (WIDTH x HEIGHT x THICKNESS)

SCOPE OF WORK

REFERENCE SECTION

QTY.

D 1 EXTERIOR DOOR 36" x 80" x 1-1/2" 2.2.7 5

D 2 DOOR W/WINDOW 36" x 80" x 1-1/2" 2.2.7 1

D 3 HALF-DOOR INTERIOR 28" x 80" x 1-3/8" 2.2.8 1

D 4 FULL-DOOR INTERIOR 36" x 80" x 1-3/8" 2.2.8 5

D 5 EXISTING DOOR 36" x 80" x 1-3/8" N/A N/A

WINDOW SCHEDULE

CALL

OUT TYPE DESCRIPTION

DIMENSIONS

(WIDTH x HEIGHT)

SCOPE OF WORK

REFERENCE SECTION

QTY.

W 1 SMALL WINDOW 36" x 36" 2.2.6 3

W 2 LARGE WINDOW 60" x 36" 2.2.6 2

W 3 EXISTING WINDOW 60" x 36" N/A N/A

DOOR

CALL-OUT

TYPE (SEE SCHEDULE)

WINDOW

CALL-OUT

TYPE (SEE SCHEDULE)

STORAGE ROOM

(488 SQ. FT.)

CONFERENCE ROOM

(655 SQ. FT.)

RESTROOM

(130 SQ. FT.)

KITCHEN

(86 SQ. FT.)

LUNCH ROOM

(312 SQ. FT.)

MAP ROOM

(168 SQ. FT.)

HALLWAY

(170 SQ. FT.) EXERCISE ROOM

(368 SQ. FT.)

RESTROOM

(130 SQ. FT.)

UTILITY ROOM

(86 SQ. FT.)

D

W

0 1 2 3 4 8 12

S C A L E : 1 4 " = 1 ' - 0 "

G R A P H I C S C A L E

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

FRAMING PLAN

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 3 OF 6

ROOF LINE

R-1A R-2A B-1

B-2R-1B

R-2B

FRAMING SCHEDULE

TYPE DESCRIPTION

SIZE

(BASE x HEIGHT x LENGTH)

ACTUAL DIMENSIONS

(BASE x HEIGHT x LENGTH)

B-1 BLOCKING, DOUG. FIR 2" x 8" x 2' 1-1/2" x 7-1/2" x 19-3/4"

B-2 BLOCKING, DOUG. FIR 2" x 8" x 4' 1-1/2" x 7-1/2" x 3'-8"

G-1 GIRDER, REDWOOD 4" x 12" x 30' 4" x 12" x 30'-4"

R-1A EXISTING RAFTER BEAM,

REDWOOD 4" x 8" x 22' 4" x 8" x 22'-2"

R-1B EXISTING RAFTER BEAM,

REDWOOD 4" x 8" x 14' 4" x 8" x 14'-2"

R-2A RAFTER SUPPORT BEAM,

DOUG. FIR

SIDE-BY-SIDE

2" x 8" x 20'

(4" x 8" x 20')

SIDE-BY-SIDE

1-1/2" x 7-1/2" x 20'-2"

(3-1/2" x 7-1/2" x 20'-2")

R-2B RAFTER SUPPORT BEAM,

DOUG. FIR

SIDE-BY-SIDE

2" x 8" x 16'

(4" x 8" x 16')

SIDE-BY-SIDE

1-1/2" x 7-1/2" x 16'2"

(3-1/2" x 7-1/2" x 16'-2")

FRAMING

TYPE (SEE SCHEDULE)

CROSS-SECTION

CALL-OUT

REFERENCE SHEET NUMBER

G-1

B

0 1 2 3 4 8 12

S C A L E : 1

S 3 S 3

S 3 S 3

S 3 S

3 S 3 S

S3S3

S 3 S 3

S3S3

S3S3

S S

S

S 3

SS SS

S

S

S

COM COM

COMCOM

CO

M

SYMBOL DESCRIPTION DATE APPR.

MENDOCINO COUNTY CALIFORNIA

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

ELECTRICAL PLAN

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 4 OF 6

CONFERENCE ROOM

(655 SQ. FT.)

RESTROOM

(130 SQ. FT.)

KITCHEN

(86 SQ. FT.)

LUNCH ROOM

(312 SQ. FT.)

MAP ROOM

(168 SQ. FT.)

HALLWAY

(170 SQ. FT.)

RESTROOM

(130 SQ. FT.)

ELECTRICAL

CALL

OUT DESCRIPTION

1 EXISTING ELECTRICAL PANEL

2 EXISTING COMMUNICATIONS SERVER

3 RANGE OUTLET (STOVE)

4 EXISTING COMMUNICATION PORT

0 1 2 3 4 8 12

S C A L E : 1

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

HEATING, VENTILATION & AIR CONDITIONING PLAN

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 5 OF 6

STORAGE ROOM

(488 SQ. FT.)

CONFERENCE ROOM

(655 SQ. FT.)

RESTROOM

(130 SQ. FT.)

KITCHEN

(86 SQ. FT.)

LUNCH ROOM

(312 SQ. FT.)

MAP ROOM

(168 SQ. FT.)

HALLWAY

(170 SQ. FT.)

EXERCISE ROOM

(368 SQ. FT.)

RESTROOM

(130 SQ. FT.)

2 3 41

R-1 R-2 R-3

R-4

R-5

R-6

R-7R-8R-9

REGISTER DESIGN

FLOWRATES

REGISTER NO.

OUTFLOW

(CFM)

R-1 300

R-2 300

R-3 300

R-4 250

R-5 235

R-6 235

R-7 130

R-8 220

R-9 220

HVAC CALLOUT INFORMATION

CALLOUT TITLE DESCRIPTION

1 ELECTRICAL PANEL CONNECT TO PANEL W/NEW BREAKER

2 HEAT PUMP

6 TON, 208/230 VOLT, 3 PHASE, 60 Hz, (REINFORCED CONCRETE PAD 42" x 40" x 4")

3 PLENUM OVERHEAD PLENUM TO FIT DESIGN

4 AIR HANDLER 6 TON, 2,250-3,750 CFM

5 RETURN PLENUM RETURN AIR INTAKE, 42" x 18"

0 1 2 3 4 8 12

S C A L E : 1

COYOTE VALLEY DAM/LAKE MENDOCINO

BUILDING #2 RENOVATION

PLUMBING PLAN

US ARMY CORPS OF ENGINEERS

SAN FRANCISCO DISTRICT

OPERATIONS TECHNICAL SUPPORT OFFICE

3333 SKAGGS SPRINGS ROAD

GEYSERVILLE, CA 95441

SHEET NO. 6 OF 6

H C

W.H.

APPROXIMATE LOCATION OF

EXISTING WATER HEATER

(66 GAL. CAP.; 220 V; 5,000W)

DISHWASHER

REFERENCE 2.4.5

0 1 2 4 6

S C A L E : 1 2 " = 1 ' - 0 "

File details come from the government source that posted it. Updated .