ARRA2-Renovation of Building 2 Drawings.pdf
PDF 424 KB Posted
- Attached to
- RECOVERY: Renovation of Building #2 at Coyote Valley Dam, Lake Mendocino, CA Project No 4230
- Solicitation number
- W912P7-10-B-0007
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Results Mar 31 2010.pdf | ||
| Amendment 1 to Solicitation.pdf | ||
| Questions and Answers.pdf | ||
| Bid Bond form.pdf | ||
| Questions and Answers.doc | DOC document | |
| WalkThruAttend.pdf | ||
| 61-43-17 Sheet 10D.PDF | ||
| 61-43-17 Sheet 11B.PDF | ||
| Scope of Work CVD Bld 2 Renov - ARRA 23.pdf | ||
| W912P7-10-B-0007.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARK HEADQUARTERS
SEE LOCATION MAP
La ke
M en do ci no
To Hopland
To Willits
Ukiah
Calpella
The Forks
GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO
STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE CORPS OF
ANY DISCREPANCIES.
2. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE
ALERT (USA) AT LEAST 48 HOURS IN ADVANCE OF ANY EXCAVATION
(1-800-642-2444).
3. CONTRACTOR SHALL PROVIDE ADEQUATE DUST CONTROL AT
ALL TIMES AS REQUIRED BY ARMY CORPS REPRESENTATIVES AND
THE BAAQMD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COSTS DUE TO AIR QUALITY VIOLATIONS. CONTRACTOR SHALL
PROVIDE NOISE CONTROL AT ALL TIMES.
4. CONTRACTOR SHALL EXERCISE ALL NECESSARY CAUTION TO
AVOID DAMAGE TO ANY EXISTING TREES, LANDSCAPING,
IRRIGATION SYSTEMS, FENCES, BOLLARDS, OR SURFACE
IMPROVEMENTS, OR TO ANY EXISTING DRAINAGE STRUCTURES,
WATER STRUCTURES, SEWER CLEANOUTS, OR JUNCTION BOXES FOR
UNDERGROUND ELECTRIC, TELEPHONE, OR STORM SEWER,
SANITARY SEWER, WATER LINE, AND UNDERGROUND UTILITIES,
WHICH ARE TO REMAIN IN PLACE, AND SHALL BEAR FULL
RESPONSIBILITY FOR ANY DAMAGE.
5. EXISTING UTILITY LINES WHICH ARE KNOWN TO THE ENGINEER
ARE SHOWN FOR INFORMATION ONLY. CONTRACTOR SHALL
CONDUCT NECESSARY POTHOLE OPERATION TO IDENTIFY
UNDERGROUND UTILITIES IN ADVANCE OF TRENCHING AND SHALL
BE RESPONSIBLE FOR THE VERIFICATION OF ALL EXISTING UTILITIES
IN THE FIELD AND EXERCISE ALL NECESSARY CAUTION TO AVOID
DAMAGE TO ANY EXISTING UTILITY LINE OR FACILITIES TO REMAIN
IN PLACE, WHETHER OR NOT SUCH LINES OR FACILITIES ARE SHOWN
ON THESE PLANS, AND SHALL BEAR THE FULL RESPONSIBILITY FOR
ANY DAMAGE THERETO. NO WARRANTY IS GIVEN AS TO THE
ACCURACY OF EXISTING UTILITY INFORMATION.
6. CONTRACTOR SHALL RESTORE OR REPLACE ANY DAMAGED
MONUMENTS RESULTING FROM HIS OPERATION AND SHALL BEAR
ALL COSTS OF SUCH REPLACEMENT.
SYMBOL DESCRIPTION DATE APPR.
MENDOCINO COUNTY CALIFORNIA
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
TITLE SHEET
VICINITY &LOCATION MAPS
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 1 OF 6
Redwood Valley
AMERICAN RECOVERY & REINVESTMENT ACT
BUILDING #2 RENOVATION
COYOTE VALLEY DAM/LAKE MENDOCINO
NOT TO SCALE
VICINITY MAP
LAKE M
ENDOCINO DRIVE
SCALE: 1:400
LOCATION MAP
STAGING AREA
PA
RK
H
EA
D Q
U A
RT
ER
S
BU
IL
D
IN
G
MAINTENANCE
BUILDING
BU
IL
D
IN
G
SCHEDULE OF DRAWINGS
SHEET NO. TITLE OF DRAWING
1 TITLE SHEET - VICINITY & LOCATION MAPS
2 GENERAL FLOOR PLAN
3 FRAMING PLAN
4 ELECTRICAL PLAN
5 HEATING, VENTILATION & AIR CONDITIONING PLAN
6 PLUMBING PLAN
N
N
SYMBOL DESCRIPTION DATE APPR.
MENDOCINO COUNTY CALIFORNIA
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
GENERAL FLOOR PLAN
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 2 OF 6
5'
3'
3' 2'-6"
2'-6.2"
3'-3" 17'-10" 15'-3" 12'-1" 20'-1"
20'-7"12'-4.5"7'-8"11'7'-9"9'-1.5"
3'
4'-6"
4'-6"
R1'-6"
2'-2"
2'-4.2"
1'
2'-4"
2'2'-9"
1'-10"
4'-9"
11'-9"
3'-11.5"3'-6"SIZE TO FIT EXISTING
ELECTRICAL BOX
4'
5'
12'
8'
68'-6"
32'-4"
10'-10"
15'-6"
20'-2"
39'-6"
15'-6.5"
9'-9"
15'-6"
5'
2'
2'-8"
3'
ADA STALLS
(COMPLIANT
TO ADAAG)
3'-8"
W
W
W
W
W
W
W
W
W
D
D
D
D
D
D
D
D
D
D
D
D
D
DOOR SCHEDULE
CALL
OUT TYPE DESCRIPTION
DIMENSIONS (WIDTH x HEIGHT x THICKNESS)
SCOPE OF WORK
REFERENCE SECTION
QTY.
D 1 EXTERIOR DOOR 36" x 80" x 1-1/2" 2.2.7 5
D 2 DOOR W/WINDOW 36" x 80" x 1-1/2" 2.2.7 1
D 3 HALF-DOOR INTERIOR 28" x 80" x 1-3/8" 2.2.8 1
D 4 FULL-DOOR INTERIOR 36" x 80" x 1-3/8" 2.2.8 5
D 5 EXISTING DOOR 36" x 80" x 1-3/8" N/A N/A
WINDOW SCHEDULE
CALL
OUT TYPE DESCRIPTION
DIMENSIONS
(WIDTH x HEIGHT)
SCOPE OF WORK
REFERENCE SECTION
QTY.
W 1 SMALL WINDOW 36" x 36" 2.2.6 3
W 2 LARGE WINDOW 60" x 36" 2.2.6 2
W 3 EXISTING WINDOW 60" x 36" N/A N/A
DOOR
CALL-OUT
TYPE (SEE SCHEDULE)
WINDOW
CALL-OUT
TYPE (SEE SCHEDULE)
STORAGE ROOM
(488 SQ. FT.)
CONFERENCE ROOM
(655 SQ. FT.)
RESTROOM
(130 SQ. FT.)
KITCHEN
(86 SQ. FT.)
LUNCH ROOM
(312 SQ. FT.)
MAP ROOM
(168 SQ. FT.)
HALLWAY
(170 SQ. FT.) EXERCISE ROOM
(368 SQ. FT.)
RESTROOM
(130 SQ. FT.)
UTILITY ROOM
(86 SQ. FT.)
D
W
0 1 2 3 4 8 12
S C A L E : 1 4 " = 1 ' - 0 "
G R A P H I C S C A L E
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
FRAMING PLAN
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 3 OF 6
ROOF LINE
R-1A R-2A B-1
B-2R-1B
R-2B
FRAMING SCHEDULE
TYPE DESCRIPTION
SIZE
(BASE x HEIGHT x LENGTH)
ACTUAL DIMENSIONS
(BASE x HEIGHT x LENGTH)
B-1 BLOCKING, DOUG. FIR 2" x 8" x 2' 1-1/2" x 7-1/2" x 19-3/4"
B-2 BLOCKING, DOUG. FIR 2" x 8" x 4' 1-1/2" x 7-1/2" x 3'-8"
G-1 GIRDER, REDWOOD 4" x 12" x 30' 4" x 12" x 30'-4"
R-1A EXISTING RAFTER BEAM,
REDWOOD 4" x 8" x 22' 4" x 8" x 22'-2"
R-1B EXISTING RAFTER BEAM,
REDWOOD 4" x 8" x 14' 4" x 8" x 14'-2"
R-2A RAFTER SUPPORT BEAM,
DOUG. FIR
SIDE-BY-SIDE
2" x 8" x 20'
(4" x 8" x 20')
SIDE-BY-SIDE
1-1/2" x 7-1/2" x 20'-2"
(3-1/2" x 7-1/2" x 20'-2")
R-2B RAFTER SUPPORT BEAM,
DOUG. FIR
SIDE-BY-SIDE
2" x 8" x 16'
(4" x 8" x 16')
SIDE-BY-SIDE
1-1/2" x 7-1/2" x 16'2"
(3-1/2" x 7-1/2" x 16'-2")
FRAMING
TYPE (SEE SCHEDULE)
CROSS-SECTION
CALL-OUT
REFERENCE SHEET NUMBER
G-1
B
0 1 2 3 4 8 12
S C A L E : 1
S 3 S 3
S 3 S 3
S 3 S
3 S 3 S
S3S3
S 3 S 3
S3S3
S3S3
S S
S
S 3
SS SS
S
S
S
COM COM
COMCOM
CO
M
SYMBOL DESCRIPTION DATE APPR.
MENDOCINO COUNTY CALIFORNIA
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
ELECTRICAL PLAN
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 4 OF 6
CONFERENCE ROOM
(655 SQ. FT.)
RESTROOM
(130 SQ. FT.)
KITCHEN
(86 SQ. FT.)
LUNCH ROOM
(312 SQ. FT.)
MAP ROOM
(168 SQ. FT.)
HALLWAY
(170 SQ. FT.)
RESTROOM
(130 SQ. FT.)
ELECTRICAL
CALL
OUT DESCRIPTION
1 EXISTING ELECTRICAL PANEL
2 EXISTING COMMUNICATIONS SERVER
3 RANGE OUTLET (STOVE)
4 EXISTING COMMUNICATION PORT
0 1 2 3 4 8 12
S C A L E : 1
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
HEATING, VENTILATION & AIR CONDITIONING PLAN
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 5 OF 6
STORAGE ROOM
(488 SQ. FT.)
CONFERENCE ROOM
(655 SQ. FT.)
RESTROOM
(130 SQ. FT.)
KITCHEN
(86 SQ. FT.)
LUNCH ROOM
(312 SQ. FT.)
MAP ROOM
(168 SQ. FT.)
HALLWAY
(170 SQ. FT.)
EXERCISE ROOM
(368 SQ. FT.)
RESTROOM
(130 SQ. FT.)
2 3 41
R-1 R-2 R-3
R-4
R-5
R-6
R-7R-8R-9
REGISTER DESIGN
FLOWRATES
REGISTER NO.
OUTFLOW
(CFM)
R-1 300
R-2 300
R-3 300
R-4 250
R-5 235
R-6 235
R-7 130
R-8 220
R-9 220
HVAC CALLOUT INFORMATION
CALLOUT TITLE DESCRIPTION
1 ELECTRICAL PANEL CONNECT TO PANEL W/NEW BREAKER
2 HEAT PUMP
6 TON, 208/230 VOLT, 3 PHASE, 60 Hz, (REINFORCED CONCRETE PAD 42" x 40" x 4")
3 PLENUM OVERHEAD PLENUM TO FIT DESIGN
4 AIR HANDLER 6 TON, 2,250-3,750 CFM
5 RETURN PLENUM RETURN AIR INTAKE, 42" x 18"
0 1 2 3 4 8 12
S C A L E : 1
COYOTE VALLEY DAM/LAKE MENDOCINO
BUILDING #2 RENOVATION
PLUMBING PLAN
US ARMY CORPS OF ENGINEERS
SAN FRANCISCO DISTRICT
OPERATIONS TECHNICAL SUPPORT OFFICE
3333 SKAGGS SPRINGS ROAD
GEYSERVILLE, CA 95441
SHEET NO. 6 OF 6
H C
W.H.
APPROXIMATE LOCATION OF
EXISTING WATER HEATER
(66 GAL. CAP.; 220 V; 5,000W)
DISHWASHER
REFERENCE 2.4.5
0 1 2 4 6
S C A L E : 1 2 " = 1 ' - 0 "
File details come from the government source that posted it. Updated .