This federal contract opportunity is for construction services related to the Mouse Creek 12th Street Detention Structure project in Cleveland, Tennessee. The project scope includes building a concrete spillway and box culvert, constructing an earthen berm up to 10 feet high along both sides of the spillway, grading the upstream area with a 2% slope, installing a stilling basin downstream, and armoring the downstream portion of the spillway with articulated concrete block for 25 feet to prevent erosion. The solicitation was issued by the U.S. Army Corps of Engineers Nashville District. No other details on response date, award date, pricing terms, or incumbent were provided in the opportunity description.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nashville District of Engineers
US Army Corps
W912P5-22-B-0016
Plans For
CLEVELAND, TENNESSEE
FILLAUER BRANCH CHANNEL MODIFICATION
CLEVELAND FLOOD REDUCTION PROJECT
DETENTION STRUCTURE
12TH STREET
Submitted:
George M. Uku, E.I.T.
(2.) The approval signatures appearing in the signature block on this sheet constitute approval of all drawings listed in the sheet index.
of individuals appear on these project documents within the scope of their employment as required by ER 1110-1-8152.
(1.) This project was designed by the Nashville District of the U.S. Army Corps of Engineers. The initials or signatures and registration designations
Note:
Frank C. Mills, P.E.
Chief, Survey and Mapping Section
Approved:
Joanne E. Traicoff, P.E.
Deputy Chief, Engineering and Construction Division. Chief, Engineering Services Branch
Project Engineer
Approval Recommended:
CERTIFIED FINAL DOCUMENTS - RTA
JUNE 2022
C
"O N
0' u a, C')
CD
r-- N N r--
CD
N a, u, E "O - C a.
C
E
"O a.
� C') N .s:: a..
1i1 N 0 a, (]) � C') u, LO co
C') -
E 2 (]) ro Ill E z □ i=
0 0 u::: a.. a..
p
N
M
L
J
G
F
E
D
C
B
A
3 4 5
SITE LOCATION
N.T.S.
6 7
N
IAMSON
SHALL
TE
AL
L E G E
N
D
ANNON
D
8 9
COFFEE r:
GRUNDY
�-� r SEQU
COUNTY LINE
STATE BOUNDARY - - -
PROJECTLOCATION �
VICINITY MAP
ti .. • II " t tlllllCI
E'E='EJE'E"l"====='===='='l
SCOTT
POLK
G
GILMER
11 12
SITE LOCATION
N.T.S.
13 14 15 16 17 18 19
INDEX
DRAWING NUMBER
G-001
G-002
V-001
B-001
C-001
C-002
C-003
C-004
C-101
C-102
C-103
C-301
C-302
C-303
C-304
C-500
C-501
C-502
C-503
C-504
S-101
S-102
DRAWING DESCRIPTION
Index- Location map
Legends and Symbols
Survey Control Points Map
Bore Hole Map
Civil - Work limits- Project/Laydown Location
Civil - Work limits- Borrow/Disposal
Excavation
Borrow site
Site Plan
Plan and Profile
Plan and Profile
Cross Section
Cross Section
Cross Section
Cross Section
Typical Fence Detail
Spillway Plan & Profile
Spillway Elevation View
ACB Detail
HD-TRM Detail
Spillway- Plan- Elevation
Spillway- Cross Section
US Army Corps of Engineers®
Q CD
z-zo w o"i'
-N �� Cl[ij t::::�
�� !,1 N _J -
(/l � g� !11.,.
>' Cl
LU [!]
z z Cl iiii
LU
Cl Cl f-
(.) LU LU 0::
--, :::) 0 f-0:: (.)0.. :::)
z 0::
0 f-j::: Cl) :z (.) z f :::) 0 .
Cl - Cl LU f- z 0:: ifi :"'i Cl f- LU
0 LU>
Oc, LU _J f- _J
"- LU (.)
Cl LU z
0::
:"'i�
WI
[ij t:;;
_J -g g f- ' f- 0..
z� 8�
Cl
LU
LU
I w
(/l ti _J
0..
Cl
LU
(/l z z z u t u
UJ
a..
SHEET ID
N
:'.j LU ;;l Cl N
"C
0 Z
0..
&l
LU
� i0::
� "C
LU -
::i:
Cl z"'
LU ,-.. -' N
-N "- -
LU
(/l
G-001
READY TO ADVERTISE
G
F
E
D
C
B
A
1 I 2 I 3 I 4
GENERAL NOTES
1. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITE CONDITIONS AND GRADES PRIOR TO COMMENCEMENT OF CONSTRUCTION. IF DISCREPANCIES BECOME APPARENT, THE COR MUST BE NOTIFIED PRIOR TO START OF WORK.
I
2. THE PROJECT SITE IS A PUBLIC AREA. THE CONTRACTOR MUST TAKE ALL NECESSARY SAFETY PRECAUTIONS TO PROTECT AND PROVIDE ACCESS TO ABUTTING PROPERTY, UTILITIES, PEDESTRIAN, AND VEHICULAR TRAFFIC.
3. THE CONTRACTOR MUST CONTACT THE TENNESSEE ONE CALL CENTER BY CALLING 811 TO LOCATE UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION WORK. MORE CONTACT INFORMATION CAN BE FOUND USING THE LINK "http://www.tennessee811.com".
4. UTILITIES AND SITE FEATURES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND MUST BE VERIFIED BY THE CONTRACTOR IN THE FIELD. THE CONTRACTOR MUST IMMEDIATELY REPORT ANY DISCREPANCIES TO THE COR. SERVICES OF A REGISTERED LAND
SURVEYOR ARE REQUIRED FOR LAYOUT OF WORK LIMITS AND FENCE LINE.
5. THE CONTRACTOR MUST BE RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES THAT ARE NOT DESIGNATED TO BE REMOVED WITHIN THE WORK LIMITS. UTILITIES DAMAGED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT NO ADDITIONAL COST
TO THE GOVERNMENT.
6. ALL AREAS AND FACILITIES DISTURBED DUE TO CONSTRUCTION WORK MUST BE RESTORED TO PRE- CONSTRUCTION CONDITION OR
AS SPECIFIED IN THE PLANS AND SPECIFICATION.
7. ALL WORK MUST BE IN ACCORDANCE WITH CORPS OF ENGINEERS SAFETY AND HEALTH REQUIREMENTS MANUAL EM 385-1-1.
8. THE CONTRACTOR MUST INSTALL AND MAINTAIN TEMPORARY EROSION CONTROL BEST MANAGEMENT PRACTICES (BMPs) AND IN ACCORDANCE TO SECTION 01 57 19 ENVIRONMENTAL PROTECTION OF TENNESSEE, AS NECESSARY TO CONTROL SEDIMENT AND
EROSION ON THE SITE DURING CONSTRUCTION.
9. THE CONTRACTOR MUST KEEP ALL STREETS CLEAN AND CLEAR OF MUD, STONES, DEBRIS, ETC., AS DESCRIBED IN SECTION 01 57 19
ENVIRONMENTAL PROTECTION OF TENNESSEE.
10. THE CONTRACTOR SHALL PERFORM ALL WORK WITHIN THE SPECIFIED WORK LIMITS.
11. EXISTING CONDITION MAY VARY OR DIFFER FROM THOSE SHOWN IN THE DRAWINGS.
12. ALL COORDINATES AND ELEVATIONS ARE IN FEET UNLESS OTHERWISE NOTED.
STANDARD ABBREVIATIONS
ACOE
CB
CL
CJ
COR
COE
CMP
DIA
DBH
DTM
D.I.P.
EHH
EHM
ELEV
EJ
EN
FF
FH
GF
G.D.
G.M.H.
HWL
H
TOOT
LCP
MH
MIN
MW
NGVD
NWL
NAVO
NTS
OSI
SL
RCP
SSP
TYP.
VIF
V
WLP
WL
WP
ARMY CORPS OF ENGINEERS
CATCH BASIN
CENTERLINE
CONSTRUCTION JOINT
CONTRACTING OFFICER'S REPRESENTATIVE
CORPS OF ENGINEERS
CORRUGATED METAL PIPE
DIAMETER
DIAMETER AT BREAST HEIGHT
DIGITAL TERRAIN MODEL
DUCTILE IRON PIPE
ELECTRICAL HAND HOLE
ELECTRICAL MAN HOLE
ELEVATION
EXPANSION JOINT
EXTRACTION WELL
FINISH FLOOR
FIRE HYDRANT
GRADE AT FOUNDATION
GRATE DRAIN
GRATED MANHOLE
HIGH WATER LEVEL (ELEVATION)
HORIZONTAL
TENNESSEE DEPARTMENT OF TRANSPORTATION
LOCAL CONTROL PANEL
MANHOLE
MINIMUM
MONITORING WELL
NATIONAL GEODETIC VERTICAL DATUM
NATURAL WATER LINE
NORTH AMERICAN VERTICAL DATUM
NOT TO SCALE
OCEAN SURVEYS, INC.
SLOPE
REINFORCED CONCRETE PIPE
STEEL SHEET PILE
TYPICAL
VERIFY IN FIELD
VERTICAL
WELL POINTS
WORK LIMIT
WORK POINT
5 I 6 I 7 I 8
LINE STYLES
---••-- FENCE
--J40-- DESIGN CONTOUR
- --11- - EXISTING CONTOUR
- - - - - - - - - - EXISTING EASEMENT
- . ---- CONSTRUCTION WORK LIMITS
- S S --- SANITARY FORCE MAIN
---- w - WATER MAIN
- - - - - - - - - - PROPERTY LINE
- S D --- STORM DRAIN
------ GAS LINE
SYMBOLS
STORM MANHOLE
WATER MANHOLE
TRIANGULATION POINT
ELECTRICAL MANHOLE
MONITORING WELL
WATER VALVE VAULT
FIRE HYDRANT
LIGHT FIXTURE
DRAINAGE FEATURE
DETAIL INDICATOR
PATTERNS
1111 COMPACTED BACKFILL
G RIPRAP
- EXISTING EARTH
u CRUSHED ROCK EARTH
'': i ,· ,,::,,·,'
� 0 '.' •• ,.. • .. , , " · · · • , STREAM BED I
• I " ' 0,' I
T W.L. AT '( ) WATER LEVEL
[BJ ELECTRIC HANDHOLE
C GUY WIRE
0 UTILITY POLE
0 TREE
� CATCH BASIN
@ CATCH BASIN ROUND
0 DROP CONNECTION
GRID LETTER/NUMBER
DRAWING AREA TITLE INDICATOR
- DIRECTION OF CUT
GRID LETTER/NUMBER �- GRID LETTER/NUMBER OF
OF DETAIL A X# SECTION
x--
SHEET WHERE '- _ ,,7""11f---- SHEET WHERE
DETAIL IS SHOWN SECTION IS SHOWN
SECTION INICATOR
� ARTICULATED CONCRETE BLOCK
GRADED TOPSOIL & SEEDING
• · CONCRETE
-: 4 .
.... 4,.
I 9 I 10
US Army Corps of Engineers®
U wWO'.
-, ::,0 >- 1!'. u o._ ::, Zll'. 0 >-j::: C/) :z uz > ::, 0 -o-o w >- z I!'. ifi 5 0 r- Wo�a-;
g I- ...J u. w u oW zll'.
5�
WI
a-; t;;
...J�
...I
0III
::i:
Cl z
Cl z w (!) w ...I
SHEET ID
CLB
w w !;;:
ui 0 w t C/) w z ::J
IC
:a
I!'.
Cl)
C/) w z w z w
0 wz zo o-> >- o._ cii ii':
OU
o._ Cl)
WW
I!'. 0
G-002
S O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
F
IL
E N
A M
E
P R
O J E
C T
I D
T
H S
T R
E E
T D
E T
E N
T
IO
N S
T R
U C
T U
L
E V
E L
A N
D T
N
C L
E V
E L
A N
D F
L O
O D
R E
D U
C T
IO
N
P R
O J E
C T
W P
-2
-X
X X
X
(D
A T
E
W P
-2
-X
X X
X
N A
S H
V
IL
L E
D
IS
T R
IC
T
-3
C
L B
V
-0
.d g n
B
R O
A D
W A
Y
N A
S H
V
IL
L E
T
N
LOCALITY
COUNTRY
LATITUDE
(NORTHING) (US FT) (EASTING) (US FT)
LONGITUDE
STAMPING ON MARK
TYPE OF MARK STATION
AGENCY (CAST IN MARK)
DATUM
GRID AND ZONE DATE ORDER
ESTABLISHED BY (AGENCY)
DATUM
ELEVATION
DESCRIPTION:
N
LOCALITY
COUNTRY
LATITUDE
(NORTHING) (US FT) (EASTING) (US FT)
LONGITUDE
STAMPING ON MARK
TYPE OF MARK STATION
AGENCY (CAST IN MARK)
DATUM
GRID AND ZONE DATE ORDER
ESTABLISHED BY (AGENCY)
DATUM
ELEVATION
DESCRIPTION:
N
LOCALITY
COUNTRY
LATITUDE
(NORTHING) (US FT) (EASTING) (US FT)
LONGITUDE
STAMPING ON MARK
TYPE OF MARK STATION
AGENCY (CAST IN MARK)
DATUM
GRID AND ZONE DATE ORDER
ESTABLISHED BY (AGENCY)
DATUM
ELEVATION
DESCRIPTION:
N
11TH STREET NE
A
R O
L
IN
A A
V E
N U
E N
E
13TH STREET NE
USACE
APRIL 2009
MODIFIED 22 1959
1 OCT 04
DAFORM
CONTROL MONUMENT
NOT TO SCALE
USACE
APRIL 2009
MODIFIED 22 1959FORM
1 OCT 04
DA
CONTROL MONUMENT
USACE
APRIL 2009
MODIFIED 22 1959FORM
1 OCT 04
DA
CONTROL MONUMENT
NOT TO SCALE
the proponent agency is TRADOC.
For use of this form see FM 3-34.331;
HORIZONTAL CONTROL STATION
DESCRIPTION OR RECOVERY OF
agency is TRADOC.
3-34.331; the proponent For use of this form see FM
HORIZONTAL CONTROL STATION
DESCRIPTION OR RECOVERY OF
HORIZONTAL CONTROL STATION
DESCRIPTION OR RECOVERY OF
APPROXIMATELY 0.28 MILES TO THE MARK ON THE RIGHT.
11TH STREET NE, TRAVEL EAST ALONG 11TH STREET NE
FROM THE INTERSECTION OF PARKER STREET NE AND
LEFT.
ON THE LEFT. MARK IS APPROXIMATLEY 230 FEET ON THE
APPROXIMATELY 0.24 MILES TO PARKING LOT ENTRANCE
11TH STREET NE, TRAVEL EAST ALONG 11TH STREET NE
FROM THE INTERSECTION OF PARKER STREET NE AND
U.S.A. HUBTACK U.S.A. MAGNAILCP2 867.29 CP3 855.57 U.S.A. MAGNAIL CP4 864.44
NONE N/A NAVD88
NAD83 (2011) USACE
303828.02 2307743.14 TN 4100 3RD
NONE N/A NAVD88
USACENAD83 (2011)
304061.94 2307550.51 TN 4100 3RD
NAVD88N/ANONE
NAD83 (2011) USACE
3RDTN 41002307514.25304132.41
12TH STREET NE
A N
S I
D
B E
N L
R
O H
R B
A C
H P
.E
C O
N T
R O
L P
O
IN
T S
V-001
T S
M
F C
M
T
IM
O T
H Y
S
M O
Y A
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
CP2
CP4
CP3
CP2
CP3 CP4
WORK LIMITS
CONSTRUCTION
NOT TO SCALE
BRADLEY CO. BRADLEY CO. BRADLEY CO.
LEFT.
ON THE LEFT. MARK IS APPROXIMATLEY 170 FEET ON THE
APPROXIMATELY 0.24 MILES TO PARKING LOT ENTRANCE
11TH STREET NE, TRAVEL EAST ALONG 11TH STREET NE
FROM THE INTERSECTION OF PARKER STREET NE AND
PATIAL REFERENCE SYSTEM VIA NGS.
ALL HORIZONTAL AND VERTICAL CONTROL POINTS ARE REFERENCED TO THE NATIONAL 4.
OF 1988 (NAVD88) U.S. FEET.
ALL ELEVATIONS SHOWN ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM3.
COORDINATE SYSTEM, ZONE 4100, NORTH AMERICAN DATUM OF 1983 (NAD83) U.S. FEET.
ALL COORDINATES SHOWN ARE REFERENCED TO THE TENNESSEE STATE PLANE2.
ACCORDINGLY IN THE BID.
TO ASSESS THE EXISTING CONDITIONS AT THE TIME OF BIDDING, AND INCLUDE COST
DIFFER FROM THOSE SHOWN. THE CONTRACTOR SHALL TAKE ALL NECESSARY ACTIONS
EXISTING AT THAT TIME. EXISTING CONDITIONS DURING CONSTRUCTION MAY VARY AND
PERFORMED BY THE U.S. ARMY CORPS OF ENGINEERS AND REPRESENTS CONDITIONS
THE SURVEY CONDITIONS SHOWN ON THESE DRAWINGS ARE FROM A MAY 2020 SURVEY1.
NOTES:
TRADOC.
3-34.331; the proponent agency is For use of this form see FM
304061.94
303828.02
304132.41CP2
CP3
CP4
867.29
855.57
864.44 MAGNAIL
MAGNAIL
HUBTACK
DESCRIPTION
TN NAD83 STATE PLANE COORDINATES
NORTHING (Y)
HORIZONTAL & VERTICAL CONTROL POINTS
(PID)
POINT
NAVD88
ELEV.
EASTING (X)
2307514.25
2307743.14
2307550.51
NN
/2
R e p o s it io n e d
C o n s tr u c ti o n
L im it s P la n w in d o w a d ju s te d t e x t s iz e f o r
H o ri z o n ta l
V e rt ic a l
C o n tr o l
P o in ts t a b le a d ju s te d N o te s t e x t s iz e
El, BORING LOCATION z w ....J w
1+00
FBDP-1
FBDP-1
O,()Q m i z
5 � Cl:::!! ci> m r, c:
IQ
-z
1+50
FBDP-2@
FBDP-4
FBDP-3
@ FBDP-6
12TH STREET SUBSURFACE
EXPLORATION PLAN
SCALE: 1" = 20'
FBDP-3
FBDP-4
FBDP-6 FBDP-2
� v..r,m 0 W//$4!!
/fl'/,:,;
��6
W,0 0� w&�W/$//A
W/,W,°� w,Wr,:,;
W/,W,°� mJ mJ "'C) 0 m i z
5 < "-< Cl!! v.i mr>c:
IQ
-z"'
� ,..,.,w,Wr,:,; � w&� � W/� v,:,;
- 0 0 W/� V,0 � W$7f6 "
W/� W/$� -w,Wu,.; �/ffr/6
- >'<7$/4!
vq,W�
W/$� -v,:,;W�
- W/�Vq43'v,:,;
W/� O,()Q ,w43'v,:,; rn�z
5 < "'"0 "'"0 ��< m�z m�z o:!!ci.i 5 � 5 � mOC:
:::E�< ::E�< ��� 0 !! ci.i o::!!u.i IQ m�c: m� c: -z:s =' F' :s� F' "
IQ IQ
:::;z -z "'
2+00 2+50
STATION
12TH STREET SUBSURFACE
EXPLORATION PROFILE
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
FBDP-5
DETENTION STRUCTURE
BASELINE
FBDP-5
Vq� � 0 woW,.a
,,.�,., 0,0 W/$/4! �/oWUA
W/$/4! Vq$,",:,;
>'<7/$4!!
W,& 7-0
��,.,0,0.,� vq$<
� � ,w,?";l O,()Q m>z 5(/.)� �!:f!s;
o::!!oo mOC:
:!J��
IQ
:::;:z
3+00 3+50
-2
10 I I-a..
w
APPROXIMATE BOREHOLE LOCATION
HOLE ID NORTHING (Y) EASTING (X) ELEVATION (Z)
FBDP-1 304,189.45 2,307,633.33 852.14
FBDP-2 304,179.50 2,307,700.06 853.21
FBDP-3 304,171.95 2,307,728.29 854.54
FBDP-4 304,121.72 2,307,660.67 851.59
FBDP-5 304,082.56 2,307,800.92 852.59
FBDP-6 304,019.40 2,307,691.04 852.60
LEGEND:
� FAT CLAY >'<7,W,°/��
w,@w;ffW$<
- CLAYEY SAND
- LEAN CLAY
11 msw II US Army Corps of Engineers® ij w
:c ui I
>- f;'!
_j " z " "' LU e= >- a, w w z f- M (!) u z a:' w f- M
u. !!1 z 0 □ f- Cl) w wD.. ...J ...Jct: ...J cc! 0 5 > u I I
Cl) ct: z z
:::J f- Uw w ct:
--, :::J0 f-ct: u D.. :::J z ct:
0 f-f'.= Cl) z u z f- <( :::J O - � □-□ w f- z (!)
ct:
z <( w ...J z
□ f- w ll:'. 0W> o
□w 0 ...J f- ...J fl] u. w (.)
□W z ct:
:5 tii w > f-w N ...J � u
Sheet
ID
B-001 0 0
C m :z
1ii z
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
E N
A M
O J E
C T
I D
WL 02
WL 04
WL 07
WL 01
WL 03
WL 05
WL 06
IPO
IE 848.71OUT
RIM 858.02
62-58X
MANHOLE I.D.
12TH STREET NE
C A
R O
L
IN
A S
T R
E
T
O W
F L O
W
F L
O W
859'
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
T H
S T
R E
E T
D E
T E
N T
IO
N
S T
R U
C T
U
O
T S
C A
L E
F
IL
E N
A M
E V
E L
A N
D T
N
C L
E V
E L
A N
D F
L O
O D
R E
D U
C T
IO
N
P R
O J E
C T
(D
A T
E
N A
S H
V
IL
L E
T
N
B
R O
A D
W A
Y
N A
S H
V
IL
L E
D
IS
T R
IC
T
A N
S I
D
T S
M
F C
M
B E
N L
R
O H
R B
A C
H
P .E
T
IM
O T
H Y
S
M O
Y A
W O
R K
L
IM
IT
S
-3
C
L B
C
-0 .d g n
P R
O J E
C T
L
A Y
D O
W N
A1
SCALE: 1" = 30' 30' 60'0
NORTH
PLAN
T R
U E
N
WORK LIMITS - PROJECT LOCATION
C-001
W P
-2
-X
X X
X
W P
-2
-X
X X
X
READY TO ADVERTISE
WORK LIMITS (WL)
TN NAVD 83
CHRUCH PARKING LOT IS OFF LIMITS
L O
C A
T
IO
N
WL 07
WL 06
WL 05
WL 04
WL 03
WL 02
WL 01
POINT
303,843.88
303,826.45
304,053.40
304,119.32
304,237.49
304,232.88
304,181.60
NORTHING
2307674.97
2,307,726.379
2,307,867.807
2,307,875.72
2,307,643.50
2,307,600.67
2,307,574.43
EASTING
TN NAVD 83
LA 04
LA 03
LA 02
LA 01
POINT
LAYDOWN AREA (LA)
303,779.60
303,745.60
303,782.20
303,815.60
NORTHING
2,307,748.0
2,307,824.7
2,307,840.9
2,307,765.6
EASTING
LA 01
LA 02
LA 03
LA 04
WORK AREA LIMITS
TO CONSTRUCTION TRAFFIC
12th STREET IS OFF LIMIT
AREA ENTERENCE
POSSIBLE WORK
EXISTING TREES
DO NOT DISTURB
PROPOSED LAYDOWN AREA
EXISTING FENCE
EXISTING SEWER LINE
CONSTRUCTION FOR THE CHURCH OF GOD BUILDING.
11. CONTRACT IS REQUIRED TO MAINTAIN ACCESS EASEMENT DURING
ROADWAY BARRIER PLAN FOR COR APPROVAL PRIOR TO CONSTRUCTION.
THE GOVERNMENT. SUBMIT A PROPOSED SAFE CONSTRUCTION SITE AND
SAFETY, THE CONTRACTOR SHALL SUPPLY THEM AT NO ADDITIONAL COST TO
DETERMINES THAT ADDITIONAL BARRIERS ARE REQUIRED FOR PUBLIC
SPECIFICATIONS, EM385-1-1, AND OSHA REQUIREMENTS. IF THE COR
KEEPING WITH LATEST VERSIONS OF MUTCD, TDOT STANDARD
TRAFFIC FROM ENTERING THE CONSTRUCTION SITE. BARRIERS SHALL BE IN
AND/OR SAFETY PERSONNEL SO AS TO PREVENT VEHICLE AND PEDESTRIAN
PROVIDE NECESSARY ROADWAY, SAFETY AND CONSTRUCTION BARRIERS 10.
AND MINIMIZE IMPACT TO THE SITE.
USE BEST MANAGEMENT PRACTICES TO PROTECT EXISTING STRUCTURES
RETURNED TO THEIR ORIGINAL CONDITION PRIOR TO FINAL ACCEPTANCE.
STRUCTURES THAT ARE IMPACTED BY CONSTRUCTION EFFORTS SHALL BE
UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS, ANY EXISTING 9.
OFFICER.
LAYDOWN LIMITS UNLESS OTHERWISE APPROVED BY THE CONTRACTING
CONTRACTOR STAGING AREAS SHALL BE LOCATED WITHIN THE PROJECT 8.
IS NEEDED DURING THE CONSTRUCTION PERIOD.
ARE REQUIRED WHEREIT IS EVIDENT THAT EROSION OR SEDIMENT CONTROL
AT A MINIMUM, EROSION CONTROL BEST MANAGEMENT PRACTICES (BMPS) 7.
CONSTRUCTION PERIOD.
TO COMMENCING EARTHWORKAND SHALL BE MAINTAINED THROUGHOUT THE
ALL NECESSARY EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR 6.
CORPS OF ENGINEER'S SAFETY MANUALEM 385-1-1.
ADDITIONALLY, ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
OCCUPATIONALSAFETY AND HEALTH ADMINISTRATION (OSHA) REGULATIONS.
CONTRACTOR SHALL MAINTAIN SAFETY PRACTICES THAT CONFORM TO 5.
AREAS, UTILITIES, ETC. DUE TO DAMAGE BY CONSTRUCTION ACTIVITIES.
ALSO RESPONSIBLE FOR ANY REPAIRS NEEDED TO THE STREETS, PARKING
THE EQUIPMENT AND TOOLS NEEDED TO CLEAN ROADS. THE CONTRACTOR IS
MUD, ETC. AT ALL TIMES. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING
CONTRACTOR SHALL KEEP ALL ROADS CLEAN OF CONSTRUCTION DEBRIS, 4.
2016.
ACCORDING TO THE SOFTWARE, THE IMAGERY WAS CAPTURED IN OCTOBER
IMAGERY WAS IMPORTED INTO MICROSTATION FROM GOOGLE EARTH. 3.
CONTRACTOR UPON CONTRACT AWARD.
CAD, SURVEY, AND TERRAIN MODEL FILES SHALL BE MADE AVAILABLE TO THE
TENNESSEE STATE PLANE US SURVEY FEET. VERTICAL DATUM IS NAVD 88.
COORDINATE AZMUTHS AND DISTANCES SHOWN ARE BASED ON NAD 83 2.
PROPERTY.
CONTRACTOR SHALL NOT DO NOT TRESPASS ON ADJACENT CHURCH
CONTRACTOR MAY ACCESS THE SITE FROM CAROLINA STREET. THE 1.
NOTES:
CLB
/2
A d ju s te d t e x t s iz e
D
C
B
A
1 2
WORK LIMITS - DISPOSAL LOCATION
SCALE: 1" = 30'
Yi /ff fE i
BL02
BL01
3 4 5
0 30'- -
PLAN
NORTH
EB
60'
9 10
DISPOSAL LOCATION (BL)
POINT NORTHING EASTING
BLOl 299163.33 2308618.25
BL02 299272 .91 2308627 .11
BL03 299363.68 2308657.36
BL04 299243.21 2308992.47
BL05 299074.05 2308936.94
GENERAL NOTES:
1. THE DISPOSAL AREA ADDRESS IS 355 Hill St SE AND IS OWNED BY THE CITY.
2 . ALL WORK PERFORMED IN THE DISPOSAL AREA SITE SHALL NOT DAMAGE
THE UTILITIES AND IS TO BE APPROVED BY THE CONTRACTING OFFICER. FILL
PLACEMENT AROUND AND UNDER POWER LINES SHALL BE COORDINATED
WITH THE LOCAL POWER COMPANY.
3 . PROVIDE NECESSARY ROADWAY, SAFETY AND CONSTRUCTION BARRIERS
AND/OR SAFETY PERSONNEL SO AS TO PREVENT VEHICLE AND PEDESTRIAN
TRAFFIC FROM ENTERING THE CONSTRUCTION SITE. BARRIERS SHALL BE IN
KEEPING WITH LATEST VERSIONS OF MUTCD, TOOT STANDARD SPECIFI
CATIONS, EM385-1-1, AND OSHA REQUIREMENTS. IF THE COR DETERMINES
THAT ADDITIONAL BARRIERS ARE REQUIRED FOR PUBLIC SAFETY, THE
CONTRACTOR SHALL SUPPLY THEM AT NO ADDITIONAL COST TO THE
GOVERNMENT. SUBMIT A PROPOSED SAFE CONSTRUCTION SITE AND ROAD
WAY BARRIER PLAN FOR COR APPROVAL PRIOR TO CONSTRUCTION.
4 . CONTRACTOR SHALL MAINTAIN SAFETY PRACTICES THAT CONFORM TO
OCCUPATIONALSAFETY AND HEALTH ADMINISTRATION (OSHA) REGULATIONS.
ADDITIONALLY, ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
THE CORPS OF ENGINEER'S SAFETY MANUALEM 385-1-1 .
5 . CONTRACTOR SHALL KEEP ALL ROADS CLEAN OF CONSTRUCTION DEBRIS,
MUD, ETC. AT ALL TIMES. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING
THE EQUIPMENT AND TOOLS NEEDED TO CLEAN ROADS. THE CONTRACTOR IS
ALSO RESPONSIBLE FOR ANY REPAIRS NEEDED TO THE STREETS, PARKING
AREAS, UTILITIES, ETC. DUE TO DAMAGE BY CONSTRUCTION ACTIVITIES.
6. IMAGERY WAS IMPORTED INTO MICROSTATION FROM GOOGLE EARTH.
ACCORDING TO THE SOFTWARE, THE IMAGERY WAS CAPTURED IN
OCTOBER 2016.
7. COORDINATE AZMUTHS AND DISTANCES SHOWN ARE BASED ON NAO 8 3
TENNESSEE STATE PLANE US SURVEY FEET. VERTICAL DATUM IS NAVO 88 .
CAD, SURVEY, AND TERRAIN MODEL FILES SHALL BE MADE AVAILABLE TO THE
CONTRACTOR UPON CONTRACT AWARD.
US Army Corps of Engineers® f-u UJUJ a:
-, ::,0 f- 1!'. u a_ ::, za:
0 f-j::: en :Z uz f ::, 0 -o-o
UJ f- z a: a'i :5 0 f- UJ 0W> oOw ...J f- ...J
u. UJ u
0 UJ
zll'.
:5 �
UJ :,:
> fUJ "' ...J� u z en � I- (.)
�o a:'. <( o en $ lr en
SHEET ID
CLB
C-002
E
D
C
B
A
I
I
'S.9.9 '
'09.9
I
I
I
I
I I
I
I I
I
I
I
I
I (/) I
I
I
I
I I 1') 1') a:)
I
I (/) I
3 4 5
CUT ARROWS
\ + CJ'
PROPOSED EXCAVATION AREA
SLOPES SHALL NOT EXCEED 1V:3H
WITHOUT BENCHING (SEE NOTE 11)
EMBANKMENT CL-P�R�O�F=l�L=-E -=B=E�L�OW
\ I
I I
I I
I I q:;
I I
I
I I
I I
I
I © I
E�ISITING SANITARY SEWER1--
r--
---\-J
I I
I
I
I
I
I
I
I
I
I
I l
I
I l.
I
I
I
I
I I
I
EXISTING
SURFACE
c96) v, � 0
15'\ " cs>� v\
I I
I
I
I a:, CJ'
(Jl
I I I I
I
/ <::5 I
I I
I
I
I
I
I I
:q, I I
I I
I
I
I I
I I
15'"
I I
I I I
I I
V
I I
I
I
I
I
----- I
I � I
I ,,'-..._ .,,,,,,,,,- - - I
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • I• • • • •
840 +----.1....---.....1.----...L..----'----.,...4-----'----__,j..__�_...,_ ____ ... ___ --+----...L..----.1....---....L.��--..L..----I-----....L.----.1...---.....,j----...1..----+-
0+00
EXISITING SANITARY
SEWER (APPROX.)
EXCAVATION
SURFACE
2+00 3+00
SEE NOTE 11
4+00
LI NE I SURF ACE I OFFSET
- 12th Street Tope -- Excavation
Scaled 1,0000 Times Ver.
9 10
NOTES:
1. ALL SUITABLE EXCAVATION MATERIA7.CONTRACTOR SHALL COMPACT SOIL WITH A SHEEP FOOT
ROLLER OR A COR APPROVED ALTERNATIVE UNLESS OTHERWISE DIRECTED.
2, AT A MINIMUM, EROSION CONTROL BEST MANAGEMENT PRACTICES (BMPS) ARE REQUIRED WHERE
IT IS EVIDENT THAT EROSION OR SEDIMENT CONTROL IS NEEDED DURING THE CONSTRUCTION
PERIOD.
3, DO NOT DISTURB EXISTING UTILITIES. ANY DAMAGE TO THE UTILITIES OR INTERRUPTIONS OF THE
SERVICE CAUSED BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED, AND THE SERVICE
RESTORED PROMPTLY, AT THE CONTRACTOR'S EXPENSE. LOCATIONS OF EXISTING ABOVE
GROUND AND UNDERGROUND UTILITIES INDICATED ON THE PLANS ARE APPROXIMATE ONLY AND
THOSE INDICATED ARE NOT NECESSARILY ALL WHICH MAY EXIST ON THE PROJECT SITE, THE
CONTRACTOR SHALL DETERMINE THE LOCATIONS OF ALL UTILITIES ON THE PROJECT SITE.
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT ALL OPEN EXCAVATIONS AND EARTHWORKS
FROM THE EFFECTS OF THE ELEMENTS AND WEATHER.
5, THE GOV RESERVES THE RIGHT TO CONDUCT ITS OWN INDEPENDENT TESTING OF MATERIALS TO INCLUDE BUT NOT LIMITED TO: SOIL, SUBGRADE, BASE, IN PLACE DENSITY,MOISTURE, RELATIVE
COMPACTION, CONCRETE SLUMP, WATER CONTENT, AND STRENGTH TESTS.
6. CONTRACTOR SHALL COORDINATE WITH COR FOR LOCATION TO PLACE MATERIAL. THE MATERIAL SHALL BE GRADED TO MAINTAIN THE CURRENT SLOPE DIRECTION. VERIFY THAT THERE IS POSITIVE
DRAINAGE. CONTRACTOR SHALL COORDINATE TRUCK HAULING ROUTES WITH THE COR FOR THE
BEST ROUTE TO LAY DISPOSAL MATERIAL.
7. CONTRACTOR SHALL COMPACT SOIL WITH A SHEEP FOOT ROLLER OR A COR APPROVED ALTERNATIVE
UNLESS OTHERWISE DIRECTED.
8. THE EXCAVATIONS PRIMARILY CLAY. HOWEVER, THE CONTRACTOR SHOULD EXPECT THE EXCAVATED MATERIAL TO CONTAIN A MIX OF SOIL TYPES; GRAVEL, ROCK, CONCRETE, AND OTHER MATERIAL. ALL
EXCAVATED MATERIAL IS TO BE PLACED IN THE DISPOSAL GRADED EMBANKMENT AREA AS
9.
10.
11.
SHOWN AND DESCRIBED .
NO CONSTRUCTION EQUIPMENT OR HAUL TRAFFIC SHALL EXCEED 15
TONS.
WHERE THE EXCAVATION SURFACE EXCEEDS 3H:1V, THE SURFACE SHALL BE BENCHED
WITH THE VERTICAL COMPONENTS NOT EXCEEDING 2 FEET AND THE HORIZONTAL COMPONENTS
BEING NO LESS THAN 2 FEET; EXCAVATION SURFACE SHALL BE IN ACCORDANCE WITH
SPECIFICATION 31 00 00.
SUBMIT A WATER CONTROL WORK PLAN IN ACCORDANCE WITH
SPECIFICATION 31 00 00. UPON GOVERNMENT APPROVAL, COMPLY WITH PLAN FOR DEALING WITH GROUND AND SURFACE WATER ON THE CONSTRUCTION SITE FOR FULL DURATION OF EXCAVATION
AND CONSTRUCTION ACTIVITIES.
12. THE 0.5" EXACAVATION BELOW THE STRUCTURE CAN EITHER BE COMPACTED OR MUD SLAB SHALL BE USED ON SITE. STRIPPED MATERIAL SHALL BE STOCK PILLED ON SITE IN PREPARATION FOR SEEDING
UPON SITE COMPLETION.
PLAN
NORTH
0-�-c�-�-�-1"=-�-�_A_N ____________________________________________________________________ _ Scaled 1.0000 Times Hor. EB
0 20' 40'
US Army Corps of Engineers® f-u UJ UJ a:-, ::, 0 f-a:u a_ ::, z za:0 f-j::: en :Z ...I uz f- ll.
::, 0 -z o-o
UJ f- z 0 a: a'i :5
� 0 f- UJ 0W>
� oOw ..J f- ..J u. UJ u (.)
0 UJ ><
zll'. w
:5 �UJ :,:
> f-UJ "' ..J � u
SHEET ID
CLB
C-003
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
E N
A M
O J E
C T
I D
:LA 01
LA 02
LA 03
LA 04
LA 05
LA 06
LA 07
LA 08
IPO
IPO
IPO
ALLEYW
AY
G A
U T S
T R
E E
T N
E
8TH STREET NE
BUILDING OUTLINE
THIS AREA
DEBRIS IN
FIELD
OPEN
FIELD
OPEN
WOODS
WOODS
(TYP)
IRON PIN NEW/SET
BUILDING OUTLINE
POST (TYP)
UTILITY POLE
HYDRANT
FIRE
FILLAUER BRANCH
A1
SCALE: 1" = 30' 30' 60'0
NORTH
PLAN
T R
U
WORK LIMITS - BORROW LOCATION
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SURFACE OFFSET LINE
LEFT BANK BORROW
EXISTING SURFACE
EXISTING SURFACE
PROPOSED BORROW CUT
PROPOSED BORROW CUT
EXISTING SANITARY SEWER LINE
APPROXIMATE LOCATION OF
0+00 0+50
0+00 1+00
LINE SURFACE OFFSET
EXISTING BORROW SITE
SCALED 1.0000 TIMES VER.
SCALED 1.0000 TIMES VER.
RIGHT BORROW AREA
EXISTING BORROW SITE
SCALED 1.0000 TIMES HOR.
SCALED 1.0000 TIMES HOR.
RIGHT BORROW AREA
LATERALS
LOCATION OF
APPROXIMATE
LEFT BORROW AREA
AREA
BORROW
PROPOSED
SITE ENTRANCE
PREFERED BORROW
WORK AREA LIMITS
BORROW SITE
0+20 0+40 0+60 0+80
0+400+20
REGARDING HAULING OVER LATERALS.
SANITARY SEWER, AND 15' FROM LATERALS FEEDING INTO THE SANITARY SEWER. COORDINATE WITH UTILITY OWNER
MAINTAIN THE FOLLOWING BUFFERS FOR EDGE OF EXCAVATION: 10' FROM CONCRETE CHANNEL, 5' FROM EXISTING9.
EXCAVATION PLAN WITH TYPICAL SECTIONS FOR THE CORS APPROVAL.
BORROW SLOPE SHALL NOT BE STEEPER THEN 1V:3H. BEFORE EXCAVATION THE CONTRACTOR SHALL PROVIDED A8.
ENSURE THERE IS POSITIVE DRAINAGE TOWARDS THE FILLAUER BRANCH7.
CONTRACTOR UPON CONTRACT AWARD.
VERTICAL DATUM IS NAVD 88. CAD, SURVEY, AND TERRAIN MODEL FILES SHALL BE MADE AVAILABLE TO THE
COORDINATE AZIMUTHS AND DISTANCES SHOWN ARE BASED ON NAD 83 TENNESSEE STATE PLANE US SURVEY FEET.6.
WAS CAPTURED IN OCTOBER 2016.
IMAGERY WAS IMPORTED INTO MICROSTATION FROM GOOGLE EARTH. ACCORDING TO THE SOFTWARE, THE IMAGERY5.
CONSTRUCTION ACTIVITIES.
RESPONSIBLE FOR ANY REPAIRS NEEDED TO THE STREETS, PARKING AREAS, UTILITIES, ETC. DUE TO DAMAGE BY
IS RESPONSIBLE FOR PROVIDING THE EQUIPMENT AND TOOLS NEEDED TO CLEAN ROADS. THE CONTRACTOR IS ALSO
CONTRACTOR SHALL KEEP ALL ROADS CLEAN OF CONSTRUCTION DEBRIS, MUD, ETC. AT ALL TIMES. THE CONTRACTOR4.
THE CORPS OF ENGINEER'S SAFETY MANUAL EM 385-1-1.
ADMINISTRATION (OSHA) REGULATIONS. ADDITIONALLY, ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
CONTRACTOR SHALL MAINTAIN SAFETY PRACTICES THAT CONFORM TO OCCUPATIONAL SAFETY AND HEALTH3.
SITE AND ROADWAY BARRIER PLAN FOR COR APPROVAL PRIOR TO CONSTRUCTION.
SHALL SUPPLY THEM AT NO ADDITIONAL COST TO THE GOVERNMENT. SUBMIT A PROPOSED SAFE CONSTRUCTION
IF THE COR DETERMINES THAT ADDITIONAL BARRIERS ARE REQUIRED FOR PUBLIC SAFETY, THE CONTRACTOR
KEEPING WITH LATEST VERSIONS OF MUTCD, TDOT STANDARD SPECIFICATIONS, EM385-1-1, AND OSHA REQUIREMENTS.
PREVENT VEHICLE AND PEDESTRIAN TRAFFIC FROM ENTERING THE CONSTRUCTION SITE. BARRIERS SHALL BE IN
PROVIDE NECESSARY ROADWAY, SAFETY AND CONSTRUCTION BARRIERS AND/OR SAFETY PERSONNEL SO AS TO2.
THE BORROW SITE LOCATION IS 525 8TH ST NE.1.
NOTES:
EXISTING SANITARY SEWER LINE
APPROXIMATE LOCATION OF
T
H S
T R
E E
T D
E T
E N
T
IO
N S
T R
U C
T U
R E
P L
O T
S C
A L
E
F
IL
E N
A M
E
C L
E V
E L
A N
D T
N
C L
E V
E L
A N
D F
L O
O D
R E
D U
C T
IO
N
P R
O J E
C T
(D
A T
E
N A
S H
V
IL
L E
T
N
B
R O
A D
W A
Y
N A
S H
V
IL
L E
D
IS
T R
IC
T
-3
C
L B
C
-0
.d g n
W P
-2
-X
X X
X
W P
-2
-X
X X
X
READY TO ADVERTISE
C-004
A N
S I
D
T S
M
F C
M
B E
N L
R
O H
R B
A C
H
P .E
T
IM
O T
H Y
S
M O
Y A
B O
R R
O W
L O
C A
T
IO
N
CLB
/2
A d ju s te d t e x t s iz e
D
E
C
A
SCALE: 1" = 20'
IGI T POI
(TYP)
PARKING LOT
DRAIN FEATURE
(TYP)
IG� T POLE
(TYP)
3 4
I I
.I - - -
I
OF CB:EST
T11DTI-I
Efl\JOTE 2 f/
PROPOSED LOCATION FOR
CONTRACTOR TO STOCK
PILE SOIL MATERIAL
6 7 8
0 20'
PLAN
NORTH
9 10
DETENTION STRUCTURE ALIGNMENT
COORDINATES
STATION NORTHING EASTING
0+00 304,140.96 2,307,588.65 0+40 304,152.64 2,307,626.90 0+45 304,154.00 2,307,631.72 0+60 304,155.19 2,307,646.66 1+00 304,158.08 2,307,686.56 1+40 304,160.97 2,307,726.45 1+66 304,162.88 2,307,752.88
TN83F NAO 83 US SURVEY FOOT
BANK LIMIT (BL)
POINT NORTHING EASTING
BL0l 304,145.94 2,307,622.13
BL02 304,124.32 2,307,629.23
BL03 304,067.95 2,307,662.03
BL04 304,061.32 2,307,654.73
BL0S 304,122.08 2,307,622.17
BL06 304,143.91 2,307,615.50
TN83F NAO 83 US SURVEY FOOT
LEGEND:
� ARTICULATED CONCRETE BLOCK
.•,, ,' ,P,','
', • , ,,,. ::, •, STREAM BED
. '":'' " ' 0'' '
\ • D" � ' ' ••'
NOTES:
1. SEE PLAN AND PROFILE WITH PROPOSED GRADING ON SHEET C-102 .
2. RE-ALIGN STREAM AS SHOWN. MAINTAIN THE EXISTING STREAM BED
ELEVATION. ENSURE THAT THE STREAM PATH FLOWS NORTH.
3. TAPER IN THE STREAM BED AS SHOWN AND TIE INTO THE EXISTING
STREAM .
4. CONTRACTOR SHALL LOCATE THE EXISING SANITAY SEWER LINE
LOCATED APPROXIMATELY WEST OF THE PROPOSED DETENTION
STRUCTURE BEFORE EXCAVATION.
5. NO ROAD CLOSURES ARE PERMITTED DURING CONSTRUCTION. THE
CONTRACTOR MUST UTILIZE TRAFFIC CONTROL MEASURES IF TRAFFIC
MUST BE TEMPORARILY OBSTRUCTED .
6. NO BLOCKING ANY DRIVEWAYS, ACCESS, OR TRAFFIC IS ALLOWED.
THE CONTRACTOR IS NOT ALLOWED TO USE 12TH STREET DURING THE
CONSTRUCTION PHASE. CONTRACTOR MAY TEMPORARY BLOCK IF
NEEDED, BUT MUST HAVE CAPABILITY TO UNBLOCK OR ALLOW ACCESS
OF NEARBY RESIDENTS, BUISNESSES, AND TRAFFIC, SUBMIT TRAFFIC
CONTROL.
7. ALL ELEVATIONS ARE IN FEET.
8. ACTUAL FIELD CONDITIONS MAY VARY. CONTRACTOR MUST FIELD VERIFY
AND NOTIFY THE COR IF A DIFFERING SITE CONDITIONS EXISTS.
9. ALL GRADED AREAS MUST BE COVERED BY 4 INCHES OF TOPSOIL AND
SEEDED, SEE SECTION 32 92 19 SEEDING.
10. CONTRACTOR MAY STOCKPILE UNSUITABLE AND ORGANIC MATERIAL
TEMPORARILY ON SITE WITHIN THE 'PROJECT LOCATION' NOT AT THE
LAYDOWN AREA. KEEP ORGANIC AND UNSUITABLE MATERIALS IN
SEPERATE STOCKPILES.
11. EROSION CONTROL IS REQUIRED FOR ANY AREAS THAT THE CONTRACTOR
HAS DISTURBED AND IS VURABLE TO EROSION. ALL TEMPORARY MATERIAL
STOCKPILES MUST HAVE TEMPORARY SEEDING, SEE SECTION 32 92 19
SEEDING. STOCKPILE MATERIAL SHALL EXCEED 3H:1V UNLESS OTHERWISE
DIRECTED BY THE COR.
12. UNSUITABLE MATERIALS/DEBRIS MUST BE DISPOSED IN OCCORDANCE
WITH LOCAL AND STATE LAWS. ANY UNSUITABLE MATERIAL OR UN-NEEDED
MATERIAL MAY BE DISOPOSED AT THE DISPOSAL LOCATION SHOWN ON
SHEET C-002 IF IT MEETS THE NECESSARY CRITERIA, SEE SECTION 31 00 00.
13. CLEARING AND GRUBBING IS REQUIRED AT ALL AREAS TO BE GRADED.
14. STREAM DEBRIS SHOULD BE CLEARED AND DISPOSED. RE-ALIGN AND GRADE
STREAM AS INDICATED, SEE SHEET C-101 FOR STREAM MODIFICAITON.
15. CONTRACTOR SHALL ADD NECESSARY BMPs.
16. CONTRACTOR SHALL COMPACT SOIL WITH A SHEEP FOOT ROLLER OR A COR
APPROVED ALTERNATIVE UNLESS OTHERWISE DIRECTED.
US Army Corps of Engineers® f- U wW(l'.
-, ::,0 f- 1!'. u a_ ::, za:
0 f-j::: en :Z uz f ::, 0 -o-o w f- z a: a'i :5 Cl f- W 0W>oO w ..J f- ..J u. w u oW zll'.
:5 � w:,:
> f W N ..J � w 1-
SHEET ID
C-101 w z ii':
u
E
D
C
B
A
IGH- POL
TYP)
2 3 4
I I ctn .0 i
L FENCE ON
TOP OF WING WALL
TREAM)
I
J cP.
I
I
I ff?
l/)
PARKING .OT
DRAIN F=EATURE
(TYP)
\ I
I
I
I
880'
870'
PLAN
I
NORTH
STRUCTURE-P
I
0 10'- - 20' - -
PROPOSED STREAM CL
STA0+94
' I I I I I I I I I I I I I I I I
00 00 00 o9 a9 Lf)9 0(0 IOg L0:2
0 a:) C\I CO N CO t> .;t.> t> -W -W -W ' >....1 >...J >...J - • -- • -- '. -------- ,_ • -- • ---<l- w.. ------- ,_ -------<l- L!J. --Q,. L!J. --'
PROPOSED SURFACE EXISTING SURFACE
PROPOSED EXCAVATION SURFACE
Z 860' - _,_ - - - - - - - _,_ - - - .3_3'y. _________ , _ _ _ _ _ _ _ _ ________________ G_Rf.p� :' Q.QOJo_: ________ , ________ , ________ , ________ , _ ---------�-------
UJ
...J 850'
UJ
EXISTING SANITARY
: SEWER LINE
' GRADE = 0.00%
• • • • 1 • • • • • • • • • 1 • • • • • • • • • 1 • • • • • • • • • 1 • • • • • • • • • 1 • • • • • • • • 1 • • • • • • • • • • • • • • • • • • 1 • • • • • • • • .J • • • • • • • • J • • • • • • • • J.... . . J • • • • • • • • l • • • • • • • • L • • • • • • • • L • • • • • • •
840' • • • • • • • '- • • • • • • • • '- • • • • • • • • • • • • • • • • • '• • • • • • • • • IO • • • • • • • • '• • • • • • • • • I• • • • • • • • • I • • • • • • • • • I • • • • • • • • •' • • • • • • • • • ' • • • • • • • • •' • • • • • • • • • • • • • • • • • •' • • • • • • • • .! • • • • • • • • .J • • • • • • • • ,I • • • • • • • • ,I • • • • • • • • I • • • • • • • • I • • • • • • • • L • • • • • • •
830' 0+70
<D' "'' .;• o-i' "'' "'' co, co, 0+80 0+90
0 r--.·8 ,00 coo -.::t'O "'"' "'""'co co co,co
1+00 1+10 co•8 m•8 ci'O cri'IJ') "'""' "'"'
CO,CO CO,CO
1+20 1+30 co•8., . �co "'""'
CO,CO
1+40
-.:t'8 N'«i "'""'
CO,CO
1+50 co'g N'g N'g M'cri cri'cri cri'C) "'""' "'""' "'""' CO,CO CO,CO co,co
1+60 1+70 1+80
N'g 0 "' "' -.:;t'C) N cri "'""' "' "' CO,CO co co
1+90 2+00 m'g. , .
� Cl "'""' co,co
2+10
12TH STREET DETENTION STRUCTURE PROFILE
lO'g. , .�"' "'""'
CO,CO
2+20 r-,..'g., .�"' "'""'
CO,CO
2+30 r,'g M'O'>"'""'
CO,CO
2+40 co'g co'g "'' <D' LC)'C) «i'cri ...:• ,,;• "'""' "'""' "'' "'' CO,CO CO,CO co, co, 2+50 2+60 2+70 2+80 2+90
880'
870'
860'
850'
840'
830'
9 10
ENBANKMENT CL ALIGNMENT DATA
Type, Station Northi1111 Earslihgi [Ell! 11ati oni
S+O 0+63.9 301-1:M).J ZD1ffi4.1 0
S+O 73.9 W4W.2 ZD1!fil.1 0
S+-0 0-+&.9 304136.2 ZD1613.S 0
3+0 O+m9 301-t!.9.1 ZD1ffi:2.:8 0
S+O l+00.9 3$4142 2-..W�4 � 3+0 + 3.9 ::MJ4"1!ri ZD16!J1.9 800
S+O 1+23.9 Jl!)j. 7.9 ZD 1.'5 aw S+O +33.9 304�.8 23:11621. ll!i<5i S+0 l+-0.9 Wi-00.8 Zll163lll.6 008
S+O +fil9 301-M.7 23:lmffl.6 l!fi:!l S-i-0 l+619 :IDil,ffl,� 2-..WWll.'5 �.§ S-t-0 +73.9 301-iffl.2 23Rt'lml.'5 l!@ill.§ S+-0 1-1&.9 Jl!)1.'M.9 ZD16l'®.'5 859.§ S+O +93.9 304 'i!l7.!!l ZD1ffi!l.'5 !!®El.§ S+O 2+m9 301-'1§1!:_ 4 23:111'9!1.4 Mil.§ S+O 2+13.9 W4M.1 2-..�1ll'OOIA 859.§ St-0 2+23.9 301-�.8 2.D1710A 85FJ.§ S+-0 2+33.9 :!1!)1.61)_!) ZD112>llA �-§
S+O 2+43.9 :!iD4iil1.2 2Dnlill.S MFJ.§ S+O 2+§3.9 3$41€.2 2DTT4'il.3 �.§ S+0 2+fil9 301-�.7 2-3Jlmll.:3 Ml!.§ S+0 2+73.9 D'l&.4 23:l�.2 0
S-t-0 2-t&.9 301-'irM.1 2.Dm®-2 0
S+0 2+93.9 304164.9 �-2
S+0 3.+m9 301-'iMi.!!l 23:l779il.2 0
S+O 3,+08. 301-'i!!,fi,.S z:Dm4.:3 0
PROPOSED RIVER CL ALIGNMENT DATA
Sl'Al'IDNI NORTIHING EAST1I.NG
POINl"li ,(flu, tffl ,(flu, O+!!Ml.O �-1 23lll7858
[Fl 1!)+11,4 :3l!WD74.2 Z2J!l7M1 .2
[Fl Ot24.§ �-s Z3>lJffl-%. J
[Fl Ot:2:'ll.1 3®� 22Jll7�.2
[Fl 0+37.§ �-4 �.1
[Fl 0+49.9 :Ml-410!!.J 23illffl3:l. J
[Fl �-6 :3l3412J.2 22l!l7fi25.
0-+39.4 304144.S 2&ll7!!1 8 §
PROPOSED CONCRETE WING WALLS LOCATIONS
Pciint North.inQI 1Ei1<5;tin Q
{flJ tft)
Sl .3114 l] 1.1 2.3117594.0
S2 3!l41S, .S 23!ll16l1Sc6
S,3 3!l413SA 23!l1&14.4
S4 3!'.J4118c9 23!'.11611!).!l
.304181!1.S 2.3076-24.6
Si& 3!14161.!) 231!176':!!).1
£1 3!14141.9 231!17621ic!)
S'!I .3114128 • .3 2.3117641!1\., LEGEND:
TURF REINFORCEMENT MAT (HP-TRM)
ARTICULATED CONCRETE BLOCK (ACB)
m US Army Corps of Engineers® f-u L!J L!J a:
---, ::,0 f-1!'. ua. ::, za:
0 f-j::: en :Z uz f::, 0 -o-oL!J f- z a: a'i :5 Cl f- L!J 0W> oO w _J f- _Ju. L!J u
0 L!J zll'.
:5 � L!J :,:
> f W "1_J � w ....I
(L
(L
SHEET ID
C-102
L!J z ii':
u
E
D
C
B
BL05
FILLAUER BRANCH
(EXISTING STREAM)
DETENTION STRUCTURE - PLAN AND PROFILE
SCALE: 1" = 10'
3 4 5
860 ---- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- 860
PROPOSED SURFACE
J_ EXISTING SURFACE
850 ---- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .,..____ - ..:....:....:. -..:....:....:. -..:....:....:. -..:....:....:. - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---4- 850
840-+----------------'-------------...L..-------------.1.----------------L---------------'--840
0+00 0+20 0+40 0+60 0+80
1+00
LINE
0 10'
PLAN
NORTH
20'- -
SURFACE
PURPOSED SURFACE
12TH STREET TOPO
SCALED 1.0000 TIMES VER.
SCALED 1.0000 TIMES HOR.
9 10
LEGEND:
� ARTICULATED CONCRETE BLOCK
,': i ,' ,P,',' � 0 , .. , •• , .. ' .. · ·" " • · STREAM BED ''� I " '' d' ', '
EXISTING
SURFACE
�-- - - - - - - - - ·: i": · - - - - - - - - - - - - - -
PROPOSED
SURFACE
840 __ ___.. __ ..._ ____ .___ ....... ___ 840 0+30
-15 o
TYPICAL TRENCH CROSS SECTION
US Army Corps of Engineers® f- U w W(l'.
--, ::,0 f-1!'. u a_ ::, za: 0 f-j::: en :Z uz f ::, 0 -o-o w f- z a: a'i :5 0 f- W 0W> oOw _J f- _J u. w u oW zll'.
:5 � w:,:
> f W N _J � w ....I
(L
(L
SHEET ID
C-103 w z ii':
u
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
E N
A M
O J E
C T
I D
SECTION
STA. 0+64
SECTION
STA. 0+89
SECTION
STA. 1+14
E L
E V
A T
IO
N
E L
E V
A T
IO
N
E L
E V
A T
IO
N
E L
E V
A T
IO
N
E L
E V
A T
IO
N
E L
E V
A T
IO
N
0 25 50 75 100-25-50-75-100
100750 25 50-25-50-75-100
1007525 500-25-50-75-100
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
FLOW DIRECTION
PROPOSED SURFACE
EXISTING SURFACE
EXCAVATION SURFACE
EXISTING SURFACE
PROPOSED SURFACE
EXCAVATION SURFACE
LEGEND:
FLOW DIRECTION
FLOW DIRECTION
T
H S
T R
E E
T D
E T
E N
T
IO
N S
T R
U C
T U
R E
F
IL
E N
A M
E
C L
E V
E L
A N
D T
N
C L
E V
E L
A N
D F
L O
O D
R E
D U
C T
IO
N
P R
O J E
C T
(D
A T
E
N A
S H
V
IL
L E
T
N
B
R O
A D
W A
Y
N A
S H
V
IL
L E
D
IS
T R
IC
T
A N
S I
D
T S
M
F C
M
B E
N L
R
O H
R B
A C
H
P .E
T
IM
O T
H Y
S
M O
Y A
C R
O S
S S
E C
T
IO
N S
S T
A
A
C-301
-3
C
L B
C
-3
.d g n
READY TO ADVERTISE
W
P
-2
-X X
X X
W P
-2
-X
X X
X
CLB
/2
C h a n g e d l in e s ty le o f
S e c ti o n s
F
E
D
C
B
A z w ...J w z w ...J w
I 2 I 3 I 4 I 5 I 6 I 7 I 8
FLOW DIRECTION
I
I-
I I I I I I I -..... - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - PROPOSED SURFACE � - - - - - - - - - - - - - - - - - - - - - _ , - - - - - - - - - - - - - - - - - - - - - - !. - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -■ I-
I
I-
_,r--�----
■ I- - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - J - - - - -
I-
� I I -- I I I
I I --- -- -....:. I I - I I I � --_.:,_-
I -.. I I I / I -
■ I- - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - -
- - - "---�: P-R-O��E:/<- -
1 _,>'� - ----,,-; __ ] __ / - - - - - - - - - - : - - - - - - - - - - - - - - - - - - - - - •
- - - - - - - - - - - - - - - - - - - -- I-
I
I-
■ ... - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - EXCAVATION SURFACE _____________ : ______________________ '. _____________________ '. ______________________ : _______________________ �
I
I-
-100
I I I I I I I '
-75
I : I I I
-50
I
-25
I I I
I I I I
I ; I '
SECTION
STA. 1+64
FLOW DIRECTION
I I I ; I '
I I I : I I I I : ' '
50 75
I I I I
I
I-
' I I I I I I
PROPOSED SURFACE
. I- - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ , - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -- t■
I-
I-
- STILLING BASIN
· EXISTING SURFACE · ·
:- - - - - - - - - - - - - - - - - - - - - - -: - - - - - - - - - - - - - - - - - - - - - - :- - - - - - - - - - - - - - - - - - - - - -- I-
I-
,... ' - - ------'--- -': - - - - - - - - - - - - - - - - - - - - -:- - - - - - - - - - - - - - - - - - - - - -:- - - - - -� -- \, �- --1- ----- �- - - - - -:- - - - - - - - - - - - - - - - - -"1-_-_\..:,li-- _- _- _-_ -_ -_- _- _- _- _-_ -_ -_- _- _- ----:�-- -_- _- _- _ -_ -_ -_ -_- _,,,- - - - - - - - -:- - - - - - - - - - - - - - - - - - - - - = � 1-- I I \. ' I I / I I -
I I \. I I I / I I I I
I I I / I I
• I- - - - - - - - - - - - - - - - - - - - - - -: - - - - - - - - - - - - - - - - - - - - - - :- - - - - - - - - - - - - - - - - - - - - f � - - - - - - - - - - - - - - - - - - - - - - : - - - - - - - - - - - - - - - - - - - - - - � - 1- - - - - - - - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - :- - - - - - - - - - - - - - - - - - - - - -- t■
1-- I I \. I I I / I I
I-
I I I I I I I I I I I I I I -
1--
I I I I I I I I I I I I I I
• I- - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - _ , - - - - - - - - - - - - - - - - - - - - - - '- - - - - - - - - - - - - - - - - - - - - - -' - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -- 1-
, ' ' - : : PROPOSED EXCAVATION SURFACE : : : :
I
I-
-100
I I I I ' .
-75
I I I I ' - I I I I I I I
-50 -25
I ' .
1+39
I
SECTION
STA. 1+38
I I I
I I I I ' .
I I I I
' - I I I I
75 100 z w ...J w z w ...J w
I 9
LEGEND:
PROPOSED SURFACE
EXISTING SURFACE
EXCAVATION SURFACE
I 10
US Army Corps of Engineers® f- U ww 0::--, :::,0 f- 0:: u a_ :::, z 0::0 f-j::: C/) :z uz f :::, 0 -o-o w f- z o:: ifi 5 0 f- Wo�a-;
g 1-- ...J u. w u oWz 0::
5�
WI
a-; t;;
_J � en + Z N
Oi'.:!:
t, Cl)
WO
Cl) I- C/) 0 en " o + 0:: 0
(.) ' i'.:!:
en
SHEET ID
CLB
C:
.iz a, 0 C: - =t" - 1l 0::c:U"' (/) .c: w uo
C-302
E
D
C
B
A z
UJ
...J
UJ
z
UJ
...J
UJ
2 3 4 5 6 7 8
FLOW DIRECTION
I I I I I I I
I I I I
PROPOSED SURFACE EXISTING SURFACE
I
---- I -- - I
- - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - _ ,_ - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - .--:-.-!-', -----_,_ -----,-------� �-:-;:r-- - I
I
PROPOSED EXCAVA�ION SURFACE /' -t-, /, _ _ _ _ _ _ _ _ _ _ _ J _ _ _ _ _ _ _ - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - _ , - - - - - - - - - - - - - - - - - - - - - - '- - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -
-100 -75 -50 -25 0
SECTION
STA.2+14
25 50 75 100
FLOW DIRECTION
PROPOSED SURFACE
: EXISTING SURFACE
PROPOSED EXCAVA�ION SURFACE/'--:-''
- - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - _ , - - - - - - - - - - - - - - - - - - - - - - '- - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -
-100
-75 -50 -25 0
SECTION
STA. 1+89
25 50 75 100 z
UJ
...J
UJ
z
UJ
...J
UJ
LEGEND:
PROPOSED SURFACE
EXISTING SURFACE
EXCAVATION SURFACE
m US Army Corps of Engineers®
C:
Cf)
'5 _gi
.iz a, 0 C: -
=t "C - " 0::
C: u "' Cf) .c: w uo
. 0::
C:
"C
Uww 0::-, ::,o ...
0:: u a_ ::, en z 0::
O>- z j::: C/) :z 0 uz ... I-::, 0 -o-o t) w ... z w o:: ifi 5 en 0 f- W en o�a-; (/) g I- __J 0u. w u oW z 0:: t) 5�
WI
a-; t;;
_J � u
SHEET ID
CLB
C-303
F
E
D
C
B
A z
> 855 w ...J w z w ...J w
I 2 I 3 I 4 I 5 I 6 I 7 I
FLOW DIRECTION
I I I I I I I
I I I I I I I
EXISTING SURFACE
•I-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .!. - - - - - - - - - - - - - - - - - - -' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -· 1-
•I-- - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - _ ,_ - - - - - - - - - - - - - - - - - - - - - l - - - - - - - - - - - - - - - - - - - - - _,_ - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - _ ,_ - - - - - - - - - - - - - - - - - - - - -•I-
. t- - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - .1 - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - '- - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - -- I-
• I- - - - - - - - - - - - - - - - - - - - - - _I - - - - - - - - - - - - - - - - - - - - - - 1_ - - - - - - - - - - - - - - - - - - - - - .1 - - - - - - - - - - - - - - - - - - - - - _ I - - - - - - - - - - - - - - - - - - - - - - I_ - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - - I - - - - - - - - - - - - - - - - - - - - - -• I-
I I I I
-100
I I I I I I I
: I I I I : I I I I --, -75 -50
I : I I I I
-25
I : I I
SECTION
STA. 3+08
FLOW DIRECTION
I I I : I I I I : I I I I :
I I --, 25 50 75
I I I I
' ... - - - - - - - - - - - - - - - - - - - - - -, - - - - - - - - - - - - - - - - - - - - - - ,- - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - -, - - - - - - - - - - - - - - - - - - - - - - ,- - - - - - - - - - - - - - - - - - - - - - -, - - - - - - - - - - - - - - - - - - - - - - , - - - - - - - - - - - - - - - - - - - - - -· r-
I-
EXISTING SURFACE
. I-- - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - ! - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - , _ - - - - - - - - - - - - - - - - - - - - -· 1-
I I I I I I
I I I I I I I
I I I I I I I
.... - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - ,_ - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - _, - - - - - - - - - - - - - - - - - - - - - - '- - - - - - - - - - - - - - - - - - - - - - J - - - - - - - - - - - - - - - - - - - - - - , _ - - - - - - - - - - - - - - - - - - - - -- I-
I I I I
-100
I I I I I I I
: I I I I : I I I I I I I I I .
-75 -50 -25
I ; I
SECTION
STA. 2+89
I I I ; I I
I I : I I I I :
I I
50 75
I I I I z w ...J w z w ...J w
I 9 I 10
LEGEND:
PROPOSED SURFACE
EXISTING SURFACE
US Army Corps of Engineers®
C:
.iz a, 0 C: - =t "C -
1l 0::
C: u
.c: w uo
"C u
CD
LL! .. ()
0. w �
I <( "?
uz� .. <( co
>-mwr--.
CD$-=
III 0::: ::::! �
Cl I u. ..-
0 ro >- 0 w oL---w >- CD w >-o::Z I Z � 1-
£1 f- ,s: u :;;..i .. �w§l<:;;w:;;CDz�w w_C:::roio::Jw_z 0 I- 0 I- 0 u. CIJ III CIJ <( f- U w w
0:: --, :::, 0 f-
0:: u
0. :::, z 0:: 0 f-j::: C/) :z uz f :::, 0 -o-o w f- z o:: ifi 5 0 f- W o�a-;
g l-- _J
u. w u oW z 0::
5�
WI
a-; t;;
_J � en z w en a!
SHEET ID
CLB
C-304
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
®of Engineers
US Army Corps
P lo t T im e
P lo t D a te
F il e N a m e
:4
:4
P
M
/2
/2 c u s e rs
\h e c e c p k \d o c u m e n ts \p w \c e lr n \d m s
\1
-3
C
L B
C
-5
.d g n
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R
BE OUTSIDE THE CLEAR ZONE.
ROADWAY SHOULDER AND THE NEAREST PORTION OF THE FENCE SHALL
THE ELEVATION OF THE FENCE POST TOP SHALL BE LOWER THAN THE A
MAY BE USED AS AN ALTERNATE.
2. FENCING TERMINALS AT RETAINING WALL DETAIL ON S-F-10D
OVER THE DRAINAGE STRUCTURE AS SHOWN ON THIS SHEET.
GREATER AND WHEN IT IS NOT FEASIBLE TO GO UP AND
1. FOR USE WHEN DRAINAGE STRUCTURE HEIGHT IS 5'-8" OR
LINE POSTS
1-S
TRAND B
ARBED W
IRE,T
OP
6" MAX.
6" MAX.
SEE STD. DWG. S-F-10 FOR DETAILS.
POST S
PACIN
G
8'-0 " M
AX
LINE POSTS
INTERMEDIATE OR
6" MAX.
FIL
L S
LOPE V
ARIE
S
POST S
PACIN
G
8'-0 " M
AX
SEE DWG. NO. S-F-10B FOR CHAIN LINK FENCE DETAILS AND SPECS.
BRACE BAR
1' INSIDE THE R.O.W. LINE
FENCING TERMINALS AT BRIDGE ABUTMENTS
FENCE UP AND OVER DRAINAGE STRUCTURES WITHOUT WINGWALLS
STOCK FENCE
CHAIN LINK FENCE
GUARDRAIL
APPROACH PAVEMENT BRIDGE
VARIES, AS DIRECTED BY THE ENGINEER
PROPOSED FENCE
BRACE PIPE
" GALV. STEEL4
WING WALL
(TYP.)
" STEEL4
PIPE CLAMP
1'-0"
(TYP.)
" BOLT8
ANCHOR RODS
"x6" CIP8
WINGWALL
SHOULDER OF ROAD
TO R.O.W.
FIELD CONDITIONS AND/OR AS DIRECTED BY ENGINEER.
CONSTRUCTION MAY BE VARIED AS REQUIRED TO MEET
OF ALL CONDITIONS WHICH WILL BE ENCOUNTERED.
AND ARE NOT TO BE CONSTRUED AS REPRESENTATIVE
NOTE: THESE INSTALLATION SCHEMES ARE TYPICAL
ENDWALL
EDGE OF SHOULDER
END POST
BRIDGE ABUTMENT
TOE OF SLOPE
EDGE OF SHOULDER
NOT TO SCALE
ENDWALL
2" GALV. STEEL POST
FENCE NEEDS APPROVAL BY THE ENGINEER.
OF THE POST, THE METHOD OF ERECTION OF THE
BREAK IN THE FABRIC. FOR APPROVAL OF OMISSION
IF THE FENCE CAN BE STRETCHED TAUT WITHOUT A
A BREAK IN THE FENCE AT THIS POST MAY BE OMITTED
NO.7 GAUGE
TENSION WIRE
NO.7 GAUGE
TENSION WIRE
ABUTMENT
BRIDGE
POST
(TYP.)
HEX HEAD BOLTS
"4 3"x48
6" MAX.
2" GALV. STEEL POST
WING WALL
2" GALV. STEEL POST
3'-6" MIN. LENGTH
2" GALV. STEEL POST
BRACE BAR
" GALV. STEEL4
PARAPET
BRIDGE
PROPOSED FENCE
BRIDGE ABUTMENT SLOPE
POST
IN CORNER
INCLUDED
MATERIAL
CORNER POST
PROPOSED FENCE
R.O.W. LINE
N.T.S.
DETAIL
PIPE CLAMP CONNECTION
N.T.S.
PLAN
N.T.S.
N.T.S.
ELEVATION
DRAINAGE STRUCTURES WITH WINGWALLS
ELEVATION
SHOULDER OF ROAD
EDGE OF SHOULDER
SEE NOTE A
SEE NOTE A
TO R.O.W.
N.T.S.
ELEVATION
N.T.S.
PLAN
TOE OF FILL SLOPE
IN CORNER POST
MATERIAL INCLUDED
DETAIL BELOW
ATTACHMENT SEE
ALTERNATIVE POST
GENERAL NOTES
C L
E V
E L
A N
D
T N
T
H S
T R
E E
T D
E T
E N
T
IO
N S
T R
U C
T U
R E
C L
E V
E L
A N
D F
L O
O D
R E
D U
C T
IO
N
P R
O J E
C T
W P
-2
-X
X X
X
W P
-2
-X
X X
X
B
R O
A D
W A
Y
N A
S H
V
IL
L E
T
N
READY TO ADVERTISE
F
IL
E N
A M
E
P L
O T
S C
A L
E
(D
A T
E
N A
S H
V
IL
L E
D
IS
T R
IC
T
T Y
P
IC
A L
F E
N C
E D
E T
A
IL
T S
M
F C
M
-3
C
L B
C
-5
.d g n
A N
S I
D
B E
N L
R
O H
R B
A C
H P
.E
C-500
T
IM
O T
H Y
S
M O
Y A
/0
/1
A D
JU
S
T E
D L
E A
D E
R S
A
D
JU
S T
E D
T
IT
L E
S F
O R
E L
E V
A T
IO
N
D
E T
A
IL
A
E
D
C
B
A
1 2 w0 I
I
:r I
17.32'
U STREAM
r
' ' 0 ' • ' ., .. ' •
J
D1
MODIFIED
STREAM BED
EL848. 5'
w0 I
.] J
CONCRETE SPILLWAY - PLAN
SCALE: 1" = 5'
PROPOSED GRADE
SEE SHEET C-102
MODIFIED
STREAM BANK
EL850'
17.32'
5'
UPSTREAM
5'
UPSTREAM
EDGE OF WING WA LSOUTHSEE NOTE 4 INLET
', ' ' , 0 ,' ,. ,. , o, ', \ ' , 0 ,' ., ,. , o, ', \ ' , 0 ,' .,. •• , o, ', \ ' , 0 ,' ,. •• , o, ', \ ' , 0 ,' .,. •• , o, ', \ ' , ,' ,. .• , o, ', ' ' , , o • , , 11 ' , • O ' , • D ' , • 0 ' , 0 I ' , ' 0 , ,/7 ,, o , p , ,17 ,• • , e, ,f7 ,, o , 0 , ,t? ,• • , e, • ,O ,• • • p • ,17 ,• • • p • , ',-;• " ' o,' , ,·,":'• " o,' , ,·,':• " o,' , ,·,-:• " o,' , ,',-;,11' o,' , ,',-;, , ' o,' , ,•,-;, FLOW DIRECTION
20'
Fillbaur Branch CL
CULVERT
EDGE
10'
FLOW DIRECTION
TOP OF
WING WALL
EL: 860'
10'
TOP OF
SPILLWAY
EL: 855'
TOP OF
CULVERT
EL: 852
, .. ,o,' o,',�•
,0, , .. ,o,' o , ',�•
,0, , .. ,o, ,0 , 0 .. , 1 o,',�•
,0, , .. ,o,' o,',�•
,0, , .. ,,,, o,',�•
,0, ,.,o, ' o,',�•
,0, 1.,00
, o,',�•
,0, o, , 0,;,.,,' o
A1
CONCRETE SPILLWAY - PROFILE
SCALE: 1" = 5'
WING WALL
(TYP)
17.32'
DOWNSTREAM
5'
NORTH
OUTLET
DOWNSTREAM
EDGE OF WING WALL
SEE NOTE 6
17.32'
15'
STILLING BASIN
(TYP)
�PLAN
cr::,NORTH
0 5' 10'- -
5'
TOP OF
STILLING BASIN
EL: 850'
10'
\.oo,e,rn
STREAM BANK
SEE NOTE 7
15'
MODIFIED
STREAM BANK
SEE NOTE 7
5'
5'
SEE NOTE 5
EXISTING STREAM
BANK
LEGEND:
NOTES:
COMPACTED BACKFILL
REFER TO SECTION 31 00 00
ARTICULATED CONCRETE BLOCK
STREAMBED & BANK
CONCRETE
1. STRUCTURAL FOUNDATIONS/JOINTS/BREAKS NOT SHOWN ON CIVIL DETAILS. SEE
STRUCTURAL SHEETS FOR DETAILS & DIMENSIONS.
2. THE UPSTREAM & DOWNSTREAM SIDES OF THE SPILLWAY MUST BE GRADED AS
SHOWN, ALL PROPOSED GRADES MUST BE COMPACTED PER EARTHWORK
SPECIFICATION 31 00 00.
3. STREAM BANK MATERIAL SHALL BE PLACED UP TO THE UPSTREAM MOUTH OF THE
CULVERT TO MEET THE CULVERT INVERT ELEVATION OF 848.5 FEET. ARTICULATED
CONCRETE BLOCK ARMORING SHALL BE USED DOWNSTREAM OF THE CULVERT
OUTLET OPENING.
4. SLOPE GRADE UP FROM EDGE OF STREAM BANK TO THE WING WALLS AT 5%. THE
STREAM BANK ELEVATION IS 850 FEET.
5. DOWNSTREAM SIDE OF SPILLWAY SHALL BE MATCHED TO GRADE.
6. ARTICULATED CONCRETE BLOCK {ACB) ARMORING SHALL SLOPE UP FROM THE
EDGES OF THE STEAM BED AT A SLOPE OF 3H:1V TO THE EDGE OF WING WALLS.
7. MODIFIED STREAM BANK SHALL TIE INTO THE EXISTING STREAM OVER A DISTANCE
OF 15 FEET.
8. TAPER STREAM BED WIDTH DOWNSTREAM OF STILLING BASIN. CONTRACTOR SHALL
TRANSITION STREAM BED WIDTH OF 10 FEET TO EXISTING STREAM BED WIDTH OVER
A DISTANCE OF 10 FEET OR LESS.
9. ARMOR STREAM BANK AND STREAM BED FROM THE EDGE OF THE NORTH OUTLET
PAST THE EDGE OF THE WING WALLS, AS SHOWN ON SHEET C-101.
10. ACB ARMORING SHALL SLOPE UP FROM STREAM BED AT A3H:1V SLOPE TO EDGE
OF THE MODIFIED BANK. OVER A DISTANCE OF 15 FEET, TRANSITION 3H:1V SLOPE
TO TIE INTO THE EXISTING STEAM BANK AND BED SLOPE.
11. ENSURE THERE IS POISTIVE DRAINAGE FROM THE UPSTREAM TO DOWNSTREAM END.
12. EXCAVATE AT LEAST 6 INCHES BENEATH THE BOTTOM OF THE STRUCTURE FOOTING
ELEVATION AND IMPLEMENT MUD SLAB OR COMPACT 6 INCHES IN ACCORDANCE WITH
SPECIFICATION 31 00 00 PRIOR TO CONSTRUCTION OF THE STRUCTURE.
0 5'- - 10'- -
SCALE: 1" = 5'-0"
US Army Corps of Engineers® f-(.) ww 0::--, ::,0 fa:: (.)a. ::, z 0::0 f-j::: C/) :zuz f ::, 0 "
□ -0 w f- z a:: ifi 50 f- W o�a-;
g I- ...J
u. w (.)
oW z 0::
5�
WI
a-; t;;
_J �
?i: w ��...I 0 Cl. c::en c..
w □ I- z w< c:: z �:'.:5 0 Cl.
SHEET ID
C-501 w z ii':(.)
E
D
C
B
A
1 2
WEST TOP OF
BERM EL: 860' TOP OF SPILLWAY
EL: 855'
PROPOSED GRADE
SLOPE UP5% • • •
'TOP
"cl:JL\Y
• EL:.8
.. .. 4 • ' '
•• -�-· ...;"' 4 �
TOP…