090292Dwgs100 _030510.pdf
PDF 4 MB Posted
- Attached to
- Multiple Award Task Order Contract Federal contract opportunity
- Solicitation number
- W912LM-10-R-0002
About this file
Prototypical Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Mpls MATOC Q A - 5-20.doc | DOC document | |
| MPLS Pre-Proposal Slides.ppt | PPT presentation | |
| Site Visit Roster - Mpls.pdf | ||
| Base Entry EAL-FORM.xls | XLS spreadsheet | |
| 2010 - MATOC EXHIBITS A-D F and G Jan 09.doc | DOC document | |
| W912LM-10-R-0002 - Mpls MATOC Solicitation.doc | DOC document | |
| 090292100 Spec_030510.pdf | ||
| MATOC EXHIBIT E.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPAIR ROOF BLDG 662
CONTACTS
CONTRACTING OFFICER'S REPRESENTATIVE
ARCHITECT & ENGINEERS
LHB, INC.
21 WEST SUPERIOR STREET, SUITE 500
DULUTH, MN 55802
PHONE: (218) 727-8446
ARCHITECT: CRAIG SCHNEUER
E-MAIL: craig.schneuer@lhbcorp.com
MECHANICAL: STEWART CRAN
E-MAIL: stewart.cran@lhbcorp.com
ELECTRICAL: JOHN TOWNSEND
E-MAIL: john.townsend@lhbcorp.com
133rd AIR WING
MINNESOTA AIR NATIONAL GUARD
OFFICE OF THE BASE CIVIL ENGINEER
614 MILITIA DRIVE
ST. PAUL, MN 55111-4112
PHONE: (612) 713-2225
FAX: (612) 713-2234
CONTACT: MAJ. MIKE PIONTEK
DEPUTY BASE CIVIL ENGINEER
michael.piontek@ang.af.mil
Minnesota Air National Guard -
133rd AIR WING ST. PAUL, MN
PN: QJKL 072919
ABBREVIATIONS
SHEET INDEX
LOCATION MAP REFERENCE INDICATORS
ROOM NAME
MATERIAL
INDICATOR
SIZE
INDICATOR
SUB TYPE IDENTIFIER
LAYERS OF GYP BD/
COVERING INDICATOR
ELEVATION
INDICATOR
WALL/ PARTITION TYPE
DOOR TAG
WINDOW/ LOUVER TAG
INTERIOR ELEVATION
REFERENCE
EXTERIOR ELEVATION REFERENCE
BUILDING SECTION REFERENCE
SECTION REFERENCE
REFERENCE TAG
REVISION NUMBER
KEYNOTES
ROOM NAME/ NUMBER101A
DETAIL NUMBER
SHEET NUMBER
G0.01
L000
101A.1
M3 1A
POINT REFERENCED
ELEVATION
PLYWOOD
WOOD BLOCKING
MATERIALS
FACE BRICK
CONCRETE BLOCK
CONCRETE BLOCK (LARGE SCALE)
WOOD STUD PARTITION
METAL STUD PARTITION
BATT INSULATION
EXTERIOR RIGID INSULATION
RIGID INSULATION (LARGE SCALE)
FINISH WOOD
GYPSUM BOARD OR PLASTER
METAL-LARGE SCALE
STONE
EXISTING (DETAILS/SECTIONS)
A
AB
AC
ACBD
ACT
ADDM
ADJ
ADJ
ADJ
AFF
AHU
ALT
ALUM
AP
APPROX
ARCH
AWT
Absolute Acoustic Acoustic Board Acoustical Ceiling Tile Addendum Adjacent Adjoining Adjustable Above Finished Floor Air Handling Unit Alternate Aluminum Access Panel Approximate Architect Acousical Wall Treatment
BB
BD
BITUM
BLDG
BLK
BLKG
BM
BMU
BOT
BRG
BUR
Bulletin Board Board Bituminous Building Block Blocking Bench Mark, Beam Burnished Masonry Unit Bottom Bearing Built-Up Roofing
CAB
CB
CI
CJ
CT
CEM
CEMPLAS
CHBD
CG
CL
CLG
CLR
CMU
CO/COR
COL
COMP
CONC
CONF
CONT
CONTR
CPT
CSG
CUH
Cabinet Catch Basin Cast Iron Control Joint Ceramic Tile Cement Cement Plaster Chalk Board Corner Guard Center Line Ceiling Clear Concrete Masonry Unit Contracting Officer (Rep) Column Composition Concrete Conference Continuous Contractor Carpet Casing
Cabinet Unit Heater
D
DBL
DEMO
DET
DF
DIA
DIM
DISP
DN
DR
DR
DS
DT
DW
DWG
Depth Double Demolition Detail
Drinking Fountain Diameter Dimension Dispenser Down Door Drain Down Spout Drain Tile Dishwasher Drawing
E
EA
EF
EFIS
EJ
EL
ELEC
ELEV
ENCL
EQ
EW
EWC
EXP
EXPMATL
EXT
EXIST
East Each Each Face Exterior Finish Insulation System Expansion Joint Elevation Electrical Elevator Enclosure Equal Each Way Elec. Water Cooler Expansion, Exposed Expansion Material Exterior Existing
FD
FDTN
FE
FEC
FIN
FLR
FP
FR
FT
FTG
FWC
Floor Drain Foundation Fire Extinguisher Fire Extinguisher Cabinet Finish Floor Fireproofing Frame Foot Footing Fabric Wall Covering
GA
GALV
GB
GEN
GI
GL
GLU LAM
GYP
Gage Galvanized Grab Bar General Galvanized Iron Glass Glued Laminated Wood Gypsum
HC
HD
HDBD
HDW
HDWD
HNDRL
HM
HORIZ
HT
Hollow Core Hand Dryer Hardboard Hardware Hardwood Handrail
Hollow Metal Horizontal Height
ID
INSUL
INT
JAN
JST
JT
Inside Diameter Insulation Interior Janitor Joist Joint
LAV
LF
LINO
LKR
LOC
MATL
MAX
MECH
MET/MTL
MEZZ
MFR
MH
MK BD
MIN
MIRR
MISC
MO
MR
MTG
Lavatory Linear Feet (Foot) Linoleum Locker Location, Locate
Material Maximum Mechanical Metal Mezzanine Manufacturer Manhole Marker Board Minimum, Minute Mirror Miscillaneous
Masonry Opening Mosure Resistant Mounting
N
NA
NIC
NTS
NO
North Not Applicable Not In Contract Not To Scale Number
OC
OD
OFF
OPNG
OPP
OH
ORIG
On Center Outside Diameter Office Opening Opposite Overhead Original
PC
PBD
PERF
PL
PLAS
PLAM
PLYWD
PREFIN
PTD
PTH
PT
QT
R
RAD
RB
RD
REC
REF
REINF
REQD
RESIL
RM
RO
RS
RTF
S
SAT
SC
SCHED
SECT
SD
SGD
SGT
SHTHG
SIM
SND
SPEC
SQ FT
SS
STL
STOR
STRUCT
SUSP
SV
Portland Cement Partical Board Perforated Plate Plaster Plastic Laminate Plywood Prefinished Paper Towel Dispenser
Paper Towel Holder Paint
Quarry Tile
Riser, Radius, Range Radiator Resilient Base Roof Drain Recessed Refigerator Reinforced Required Resilient Room Rough Opening Rough Sawn Rubber Tile Flooring
South Suspended Acoustical Tile Solid Core Schedule Section Soap Dispenser Sliding Glass Door
Structural Glazed Tile Sheathing Similar Sanitary Napkin Dispenser Specification Square Foot Stainless Steel Steel Storage Structural Suspended Sheet Vinyl
T
TB
TD
TEL
TEMP
TER
TKBD
T&G
TPD
TYP
UNEX
UNFIN
UNO
UR
VB
VCT
VERT
VIF
VWC
W W/ W/O
WC
WD
WDW
WGL
WH
WWM
WI
Tread, Toilet Towel Bar Towel Dispenser Telephone Tempered Terrazo Tack Board Tongue and Groove Toilet Paper Dispenser Typical
Unexcavated Unfinished Unless Noted Otherwise Urnial
Vinyl Base Vinyl Composition Tile Vertical Verify In Field Vinyl Wall Covering
West With Without Water Closet Wood Window Wire Glass Water Heater Welded Wire Mesh Wrought Iron
At
Angle Channel Center Line
Flow Line Plate
Feet
Inches
Number
Smoke
Square Round, Diameter
CL
FL
PL
O
SYMBOL CHARACTERS
W, X, Y, Z
V
U
T
S
R
Q
P
H
I, J, K
L
M
N
O
D
E
F
G
C
B
GENERAL NOTES
THE GENERAL CONTRACTOR, ASSOCIATED SUBCONTRACTORS AND ALL OF THEIR
SUBORDINATES SHALL FAMILIARIZE THEMSELVES WITH ALL INFORMATION LOCATED
WITHIN THE MASTER LEGEND REGARDLESS OF TRADE INVOLVED PRIOR TO
CONSTRUCTION.
1. ALL WORK SHALL BE PERFORMED IN STRICT CONFORMANCE WITH LAWS,
ORDINANCES, RULES AND REGULATIONS OF GOVERNMENT AUTHORITIES HAVING
JURISDICTIONS.
2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR AND ASSOCIATED
SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS, CONDITIONS SHOWN IN
THE CONTRACT DOCUMENTS, AND EXISTING CONDITIONS PRIOR TO BIDDING.
ANY DEVIATIONS, DISCREPANCIES, AND/OR CONFLICTS SHALL BE REPORTED
IN WRITING.
3. DO NOT SCALE: DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER
SMALL SCALE. IMPERIAL DIMENSIONS GOVERN OVER METRIC.
4. THE CONTRACTING OFFICER SHALL CONDUCT A FIELD INSPECTION OF THE
PARTITION LAYOUT AT THE JOB SITE BEFORE THE WORK IS COMMENCED.
5. REFERENCES IN THE SPECIFICATIONS TO EQUIPMENT, MATERIAL, ARTICLES
OR PROCESSES BY BRAND NAME, TRADE NAME, MAKE OR CATALOG NUMBER,
SHALL BE REGARDED AS ESTABLISHING A STANDARD OF QUALITY AND SHALL
NOT BE CONSTRUED AS LIMITING COMPETITION THE CONTRACTOR MAY AT ITS
OPINION, USE ANY EQUIPMENT, MATERIAL, ARTICLE, OR PROCESS THAT IN
THE JUDGEMENT OF THE CONTRACTING OFFICER, IS EQUAL TO THAT NAMED
IN THE SPECIFICATIONS, UNLESS OTHERWISE SPECIFICALLY PROVIDED IN
THIS CONTRACT.
6. CONTRACTOR SHALL PERFORM HIGH QUALITY WORK. MATERIALS INSTALLED
TO UNIFORM ACCURATE FIT SO THEY MEET WITH NEAT, STRAIGHT LINES, FREE
OF OPEN SEAMS OR OVERLAPS. INSTALL EXPOSED MATERIALS
APPROPRIATELY LEVEL, PLUMB AND AT ACCURATE RIGHT ANGLES, OR FLUSH
WITH ADJOINING MATERIALS. WORK OF EACH TRADE SHALL MEET OR
EXCEED ALL NATIONAL STANDARDS PUBLISHED BY THE TRADE.
7. CONTRACTOR SHALL ARRANGE TO ACCOMMODATE "NOT IN CONTRACT"
WORK. WHEN INFORMATION IS INADEQUATE, REQUEST FURTHER
INSTRUCTIONS BEFORE PROCESSING.
8. CONTRACTOR SHALL TAKE CARE TO PROTECT NEWLY INSTALLED MATERIALS.
9. PRIOR TO FINAL INSPECTION OF AND ACCEPTANCE OF THIS PROJECT, THE
CONTRACTOR SHALL HAVE PROJECT AREA FREE FROM ALL CONSTRUCTION
DEBRIS, SCRAPS, MATERIAL, AND EQUIPMENT.
10. CONTRACTOR SHALL PATCH AND REPAIR ANY AND ALL FLOORS, WALLS, BASE,
CEILING, ETC. IN A WORKMANSHIP-LIKE MANNER TO MATCH THE SURROUNDING
SURFACE AREAS WHERE THERE IS DAMAGE BECAUSE OF REMOVAL OR
REPLACEMENT OF EXISTING CONSTRUCTION.
11. ALL ACTIVE TELEPHONE AND LOW VOLTAGE LINES IN PLENUM SPACES ABOVE THE
CEILING SHALL BE BOUND TOGETHER AND SUSPENDED FROM THE BUILDING
STRUCTURE. NO LINES SHALL BE ALLOWED TO REST ON THE CEILING GRID
STRUCTURE.
12. FIRE CAULK ALL PENETRATIONS THROUGH RATED WALL ASSEMBLIES THAT OCCUR
AS A RESULT OF THIS CONSTRUCTION.
13. IF NON-IDENTIFIED, POTENTIALLY HAZARDOUS MATERIAL IS ENCOUNTERED, DO
NOT DISTURB. CONTACT OWNER IMMEDIATELY TO ARRANGE FOR REMOVAL BY
OWNER (NIC).
14. REPLACE DAMAGED SOD/SOIL DUE TO CONSTRUCTION RELATED ACTIVITIES WITH
BLACK DIRT AND NEW SOD TO ACHIEVE A UNIFORM SURFACE AND APPEARANCE.
15. REFER TO SPEC SECTION 01 2300 FOR BID OPTIONS.
16. DUAL DIMENSIONING IS USED ON PLANS WITH PRIMARY DIMENSIONS IN
MILLIMETERS (METRIC) AND FOOT AND INCHES (IMPERIAL) IN PARENTHESIS.
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT TITLE:
COPYRIGHT 2008 BY LHB, INC. ALL RIGHTS RESERVED
http://www.LHBcorp.com
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
21 W. Superior Street Suite 500 Duluth, MN 55802
TEL 218/727-8446
FAX 218/727-8456
DULUTH MINNEAPOLIS
THIS SQUARE APPEARS 1/2"x1/2" ON FULL SIZE SHEETS
CLIENT:
133RD AW
ST.PAUL, MN
QJKL 072919
03-05-10 TYPE B 100%"
Q
P ro j\ D W G S R e vi t\
A
B ld g
A
C e n tr a l.
rv t
133RD AW, ST. PAUL, MN
:3
:0
A M
MMH
CAS
090292
G0.01
PROJECT TITLE
SHEET
REPAIR ROOF
BUILDING 662
03-05-10
CRAIG SCHNEUER
20160
MINNESOTA AIR
NATIONAL GUARD
SHEET INDEX
SHEET
NO. SHEET NAME
G0.01 PROJECT TITLE SHEET
A2.21 ROOF PLAN
A2.22 ROOF DETAILS
E2.01 LIGHTNING PROTECTION AND
ELECTRICAL PLAN
E7.01 ELECTRICAL DETAILS
No Date Revision
D O
W N
E X
IS
T
IN
G
S L O
P E
D S
T R
U C
T U
R E
BOND DOWN CONDUCTOR
TO STEEL COLUMN AT TOP &
BOTTOM, & PLACES AT
PERIMETER
VERIFY USE OF EXISTING
CURBS AND EXHAUST
PENETRATIONS (REMOVE IF
DETERMINED TO BE INACTIVE).
LIGHTNING PROTECTION AIR
TERMINALS AT PERIMETER, 20'-
0" O.C. AND INTERIOR, 50'-0" O.C.
REMOVE EXIST BUILT-UP ROOF &
INSULATION TO DECK
CLEAN AND RE-PAINT
EXISTING METAL ROOF
PER SPECIFICATION
SECTION 099600.
REPLACEMENT ROOF SYSTEM:
- 6 MIL. POLYETHELENE VAPOR
BARRIER ON
EXISTING DECK.
- 5/8" GYPSUM BASED UNDERLAYMENT,
MECHANICALLY ATTACHED
- 5" POLYISO INSUL, ADHERED
- 60 MIL TPO, FULLY ADHERED
PROVIDE ROOF ACCESS
LADDER PER SPECIFICATION
SECTION 055133 AT THIS
LOCATION.
A2.21
A2.21 3
A2.21
EXISTING
SCUPPER
EXISTING
SCUPPER
EXISTING
SCUPPER
EXISTING
SCUPPER
EXISTING
SCUPPER
TAPERED
INSULATION
CRICKETS WITH
TAPER OF 1/8" /
FOOT
EXISTING CONDUIT PIPE
RESTING ON BLOCKS
1 1 1
3 3 3
D O
W N
E X
IS
T
IN
G
S L O
P E
D S
T R
U C
T U
R E
D O
W N
E X
IS
T
IN
G
S L O
P E
D S
T R
U C
T U
R E
D O
W N
E X
IS
T
IN
G
S L O
P E
D S
T R
U C
T U
R E
NEW ANTENNA MAST
(APPROX. LOCATION)
PROVIDE PER DETAIL
A2.22
A2.22
A2.22
A2.22
A2.22
20' LONG
TRAFFIC MAT
1 REMOVE EXISTING CURB AND NSTALL NEW DECKING
OVER EXISTING OPENINGS.
2 EXISTING CONDUIT ROUTED OVER ROOFTOP TO BE
RE-ROUTED BELOW ROOF. SEE ELECTRICAL DRAWINGS
AND SPECIFICATIONS.
3 REMOVE EXISTING, AND INSTALL NEW ROOF DRAIN
ASSEMBLY AND INSULATION FROM UNDERSIDE. SEE
MECHANICAL SPECIFICATIONS.
4 PRIME AND PAINT EXISTING GALVANIZED SHEET METAL
DUCTS AND VENTS PER SPECIFICATION SECTION
099600.
5 RAISE EXISTING VENTILATION CURB AS REQUIRED TO
PROVIDE MINIMUM 4" FLASHING CLEARANCE HEIGHT
FROM MEMBRANE TO TOP OF CURB. PROVIDE
ADDITIONAL HEIGHT AS REQUIRED BY MANUFACTURER
TO ACHIEVE WARRANTY. PROVIDE DUCT EXTENSIONS
AS REQUIRED.
6 EXTEND PLUMBING STACK TO 12" ABOVE NEW ROOF
SURFACE. PROVIDE NEW FROSTPROOF VENT
FLASHING.
KEYED NOTES
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT TITLE:
COPYRIGHT 2008 BY LHB, INC. ALL RIGHTS RESERVED
http://www.LHBcorp.com
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
21 W. Superior Street Suite 500 Duluth, MN 55802
TEL 218/727-8446
FAX 218/727-8456
DULUTH MINNEAPOLIS
THIS SQUARE APPEARS 1/2"x1/2" ON FULL SIZE SHEETS
CLIENT:
133RD AW
ST.PAUL, MN
QJKL 072919
03-05-10 TYPE B 100%"
Q
P ro j\ D W G S R e vi t\
A
B ld g n tr a l.
rv t
133RD AW, ST. PAUL, MN
:0
A M
MMH
CAS
090292
A2.21
ROOF PLAN
REPAIR ROOF
BUILDING 662
03-05-10
CRAIG SCHNEUER
20160
MINNESOTA AIR
NATIONAL GUARD
1/8" = 1'-0"1
ROOF PLAN
NORTH
12" = 1'-0"2
EXIST 662 ROOF - LOOKING SOUTH-EAST
12" = 1'-0"3
EXISTING METAL ROOF
12" = 1'-0"4
PROPOSED EXTERIOR ROOF ACCESS LADDER LOCATION
PRIME AND PAINT METAL DUCTS
AND VENTS AS NOTED IN NOTE
PAINT PER SPECIFICATION
SECTION 09 9600.
CLEAN, PREP AND REPAINT
EXISTING METAL ROOFING PER
SPECIFICATION SECTION 09 9600.
BID OPTION:
PROVIDE ROOF ACCESS LADDER
PER SPECIFICATION SECTION 05
5133 AT THIS LOCATION
2 4 2
PREFINISHED METAL FLASHING
TPO MEMBRANE
3/4" PLYWOOD
EXISTING
WOOD
BLOCKING
(2) 2 1/2" LAYERS
OF
POLYISOCYANUR
ATE INSULATION
BOARD
5/8" GYPSUM BOARD
DECKING
MECHANICALLY
FASTENED TO METAL
DECK
6 MIL.
POLYETHELENE
VAPOR RETARDER
LOOSE LAID OVER
DECK
3� 4�
SEE NOTE #5 - SHEET
A2.21
PREFINISHED
METAL FLASHING
TPO MEMBRANE
EXISTING
WOOD
BLOCKING
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL
DECK
6 MIL. POLYETHELENE
VAPOR RETARDER
LOOSE LAID OVER DECK
3/4" PLYWOOD
PREFINISHED
METAL CAP
FLASHING
TPO MEMBRANE
3/4" PLYWOOD
EXISTING
WOOD
BLOCKING
EXISTING BRICK
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL
DECK
6 MIL. POLYETHELENE
VAPOR RETARDER
LOOSE LAID OVER DECK
FASTENER WITH NEOPRENE WASHER
M
IN
KEEPER STRIP
SEALANT
LIGHTNING ROD BRACKET
(SEE ELECTRICAL)
M
IN
1 SEALANT
TPO MEMBRANE
EXISTING BRICK
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL DECK
6 MIL. POLYETHELENE
VAPOR RETARDER LOOSE
LAID OVER DECK
SLOPED CRICKET
INSULATION
M
IN
PREFINISHED
METAL CAP
FLASHING
3/4" PLYWOOD
EXISTING
WOOD
BLOCKING
FASTENER WITH
NEOPRENE WASHER
KEEPER STRIP
SEALANT
LIGHTNING ROD BRACKET
(SEE ELECTRICAL)
M
IN
SEALANTPREFINISHED METAL CAP FLASHING
TPO MEMBRANE
3/4" PLYWOOD
EXISTING
WOOD
BLOCKING
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL
DECK
6 MIL. POLYETHELENE
VAPOR RETARDER LOOSE
LAID OVER DECK
FASTENER WITH NEOPRENE WASHER
PREFINISHED METAL FLASHING
TPO MEMBRANE
3/4" PLYWOOD
EXISTING WOOD
BLOCKING
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL DECK
6 MIL. POLYETHELENE
VAPOR RETARDER LOOSE
LAID OVER DECK
FASTENER WITH NEOPRENE WASHER
CRICKET INSULATION
SEALANT
TPO MEMBRANE
EXISTING BRICK
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD
DECKING MECHANICALLY
FASTENED TO METAL DECK
6 MIL. POLYETHELENE
VAPOR RETARDER LOOSE
LAID OVER DECK
SLOPED CRICKET
INSULATION
SCUPPER INSERT
M
IN
PREFINISHED
METAL CAP
FLASHING
3/4" PLYWOOD
EXISTING WOOD
BLOCKING
FASTENER WITH
NEOPRENE WASHER
KEEPER
STRIP
SEALANT
LIGHTNING ROD BRACKET
(SEE ELECTRICAL)
M
IN
3/4" PLYWOOD
EXI
ST�
G
UY
ATTACHM
EN
T
6�
M I N
ABOVE
1�
7� 8�
M
IN
A
B O
V E
E X
IS
T
IN
G
G U
Y A
T T
A C
H M
E N
T
CENTERING RING PLATE OR
SET SCREWS W/ WATER TIGHT
SEAL - DO NOT DRILL ANTENNA
SHAFT.
REMOVE EXISTING GUY
WIRES & ATTACHMENT
REMOVE EXISTING TIMBER
AND BALLAST BASE
5/16" (MIN) U-BOLT OR
APPROVED FASTENER,
TOP AND BOTTOM
WELDED SLIP STOPS OR
SIMILAR MECHANISM TO
PREVENT PIPE SLIPPAGE
P 3/16" BASEPLATEL
EXISTING 40LH
BAR JOIST (TYP)
/ 4"X4"X1/4" TOP AND BOTTOM
LINDAPTER OR EQUAL
BOLTED NO-DRILL
CONNECTIONS OR
FIELD WELDED &
PAINTED TOP & BOTTOM
(TYPICAL)
V E
R
IF
Y E
X
IS
T
IN
G G
U Y
H E
IG
H
T
2 1/2" STANDARD
SCHEDULE 40 PIPE
TPO FLASHING BOOT
ROOF DRAIN ASSEMBLY
TPO MEMBRANE
(2) 2 1/2" LAYERS OF
POLYISOCYANURATE
INSULATION BOARD
5/8" GYPSUM BOARD DECKING
MECHANICALLY FASTENED TO
METAL DECK
6 MIL. POLYETHELENE VAPOR
RETARDER LOOSE LAID OVER
DECK
T Y
P
R O
O F
A S
S E
M B
L Y
MEMBRANE ROOFING
PRE-MOLDED PIPE
FLASHING
STAINLESS STEEL
CLAMPING RING
PIPE 1/2" O MIN.
6 1/2" O MAX.
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT TITLE:
COPYRIGHT 2008 BY LHB, INC. ALL RIGHTS RESERVED
http://www.LHBcorp.com
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
21 W. Superior Street Suite 500 Duluth, MN 55802
TEL 218/727-8446
FAX 218/727-8456
DULUTH MINNEAPOLIS
THIS SQUARE APPEARS 1/2"x1/2" ON FULL SIZE SHEETS
CLIENT:
133RD AW
ST.PAUL, MN
QJKL 072919
03-05-10 TYPE B 100%"
Q
P ro j\ D W G S R e vi t\
A
B ld g n tr a l.
rv t
133RD AW, ST. PAUL, MN
:0
A M
MMH
CAS
090292
A2.22
ROOF DETAILS
REPAIR ROOF
BUILDING 662
03-05-10
CRAIG SCHNEUER
20160
MINNESOTA AIR
NATIONAL GUARD
3" = 1'-0"7
MECHANICAL CURB
3" = 1'-0"3
CONTRACTION JOINT
3" = 1'-0"4
SHORT PARAPET
3" = 1'-0"1
TALL PARAPET
3" = 1'-0"2
EXPANSION JOINT
3" = 1'-0"6
ROOF/WALL CONNECTION
3" = 1'-0"5
SCUPPER DETAIL
1" = 1'-0"8
ANTENNA SUPPORT @ ROOF
3" = 1'-0"9
ROOF DRAIN DETAIL
3" = 1'-0"10
VENT STACK FLASHING (TYP.)
GENERAL SHEET NOTES KEYED SHEET NOTES
DN
DN
GND ROD
GND ROD
DNGND ROD
DN
GND ROD
DN
GND ROD
DN
GND ROD
ANT
DN
GND ROD
DN
GND ROD
1 1
CU-P
CU-P
CU-P CU-P
CU-P
AL-M
AL-M
CU-P
AL-M
CU-P CU-P
CU-P
CU-P CU-P CU-P CU-P CU-P CU-P
AL-M
AL-M
AL-M AL-M
AL-M
AL-M
CU-P CU-P
CU-P
CU-P
CU-P
CU-F
AL-M AL-M
CU-P CU-P
CU-P
AL-S
AL-S
AL-S
AL-S
AL-S
AL-S
AL-S AL-S AL-S
AL-S
AL-M AL-M
CU-F
AL-M
AL-M AL-M
CU-F
MB
MB
MB
MB
MB
ARRESTER
CU-P CU-P
CU-P
CU-PCU-P CU-P
BIMETAL
SPLICER
(4)
(4)
(2)
SPD
MAIN SWBD
(EXISTING)
INSIDE BLDG
WATER
SERVICE
INSIDE BLDG
8 8
A. ELECTRICAL CONTRACTOR SHALL BE RESPONSABLE FOR
WIRING ALL ELECTRICAL ITEMS SHOWN ON THE DRAWINGS.
B. ALL UNDERGROUND CONNECTIONS OF GROUNDING
CONDUCTORS AND LIGHTNING PROTECTION SHALL BE BY
EXOTHERMIC WELD, ALL BUILDING CONNECTIONS TO
STRUCTURAL STEEL SHALL BE BY EXOTHERMIC WELD.
C. LOCATE ALL GROUND RODS 6096mm (20'-0") FROM BUILDING
FOUNDATION. MINIMUM BURIAL DEPTH OF CONDUCTOR
762mm (30").
D. ALL DOWN CONDUCTORS AND MAIN CONDUCTORS OF
LIGHTNING PROTECTION SYSTEM SHALL BE 17 GUAGE 32
STRAND COPPER (65,536 CM).
E. NO BEND OF A CONDUCTOR SHALL FORM AN INCLUDED ANGLE
OF LESS THAN 90 DEGREES, NOR SHALL IT HAVE A RADIUS OF
BEND LESS THAN 203mm (8").
F. ALL MAIN CONDUCTORS SHALL BE COPPER EXCEPT WHERE
ALUMINUM IS REQUIRED AT MECHANICAL EQUIPMENT.
PROVIDE BIMETAL SPLICER AT TRANSITION TO ALUMINUM.
G. MOUNT STANDOFF PARAPET BASES BENEATH FLASHING.
PROVIDE SEALANT AS NECESSARY FOR INTEGRITY OF ROOF
WARRANTEE.
1 BOND TO METAL BODY PENETRATING ROOF, TYPICAL WHERE
DENOTED BY "MB".
AIR TERMINALS, MOUNTING BASES, CONDUCTORS, AND OTHER
LIGHTING PROTECTION COMPONENTS ON METAL ROOF SHALL
BE ALUMINUM. PROVIDE BIMETAL ROOF PENETRATION,
CONDUCTORS INSIDE SHALL BE COPPER.
BOND TO ANTENNA STRUCTURE. PROVIDE LIGHTING
ARRESTER AT CABLE PENETRATION INSIDE STRUCTURE, BOND
TO STEEL STRUCTURE WITH #10 AWG CU.
BOND DOWN CONDUCTOR TO TOP OF STEEL COLUMN. ROUTE
DOWN CONDUCTOR INSIDE THE GAP BETWEEN CMU AND
STEEL COLUMN WEB. REMOVE ONE CMU BLOCK NEAR BASE OF
COLUMN AND BOND DOWN CONDUCTOR TO COLUMN. CORE
DRILL ADJACENT CMU (BENEATH REMOVED CMU), PROVIDE
PVC SLEEVE, AND ROUTE DOWN CONDUCTOR THROUGH
SLEEVE. CONNECT TO THRU-WALL CONNECTOR, CONNECT TO
GROUND ROD AND GROUND RING ELECTRODE. PROVIDE
ACCESS PANEL AT REMOVED CMU BLOCK.
BOND DOWN CONDUCTOR TO TOP OF STEEL COLUMN, ROUTE
IN PVC CONDUIT TO BASE OF COLUMN, AND BOND TO STEEL.
CONNECT TO THRU-WALL CONNECTOR, CONNECT TO GROUND
ROD AND GROUND RING ELECTRODE.
BOND TO ALUMINUM LADDER.
PROVIDE TYPE 1 SPD FOR ELECTRICAL SERVICE. CONNECT
AHEAD OF MAIN SWITCH, MAXIMUM LEAD LENGTH 610mm (24").
VERIFY THAT GROUNDING ELECTRODE CONDUCTOR IS
BONDED TO WATER SERVICE AND NEAREST STRUCTURAL
STEEL COLUMN WITH #3/0 Cu, PROVIDE IF NECESSARY.
SAWCUT AND PATCH BITUMINOUS PAVEMENT AS REQUIRED
FOR INSTALLATION AND CONNECTIONS TO GROUND ROD.
DIRECTIONAL BORE BENEATH CONCRETE. RESTORE TO MATCH
EXISTING CONDITIONS.
DISCONNECT AND REMOVE EXISTING CONDUIT ROUTED OVER
ROOFTOP. PROVIDE CONDUIT AND CONDUCTORS INSIDE
STRUCTURE TO SERVE EXISTING MECHANICAL EQUIPMENT ON
ROOF. FIELD VERIFY CONDUIT AND CONDUCTOR SIZE
REQUIRED.
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT TITLE:
COPYRIGHT 2009 BY LHB, INC. ALL RIGHTS RESERVED
http://www.LHBcorp.com
21 W. Superior Street Suite 500 Duluth, MN 55802
TEL 218/727-8446
FAX 218/727-8456
DULUTH MINNEAPOLIS
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2" ON FULL SIZE SHEETS
CLIENT:
133RD AW
MPLS / ST.PAUL IAP
QJKL 072919
133RD AW, ST. PAUL, MN
03-05-10 TYPE B 100%
C
R e vi t
Lo c a l F ile s
B ld g
E le c tr ic a l M E P n tr a lw lw e d a n .r vt
:1 :3
P M
WLW
LRH
090292
E2.01
LIGHTNING
PROTECTION AND
ELECTRICAL PLAN
REPAIR ROOF
BUILDING 662
JOHN TOWNSEND
4036003-05-10
MINNESOTA AIR
NATIONAL GUARD
1/8" = 1'-0"1
LIGHTNING PROTECTION AND ELECTRICAL PLAN
COPPER LOOP CABLE
HOLDER AT (3'-0") 0/C
STANDOFF PARAPET
MOUNT POINT BASE
SOLID COPPER BLUNT
TIP AIR TERMINAL
203.2mm (8")
BARE COPPER
CONDUCTOR
COPPER BLUNT TIP
AIR TERMINAL
FLAT MOUNT POINT BASE
BARE ALUM CONDUCTOR
COPPER LOOP CABLE
HOLDER (3'-0") 0/C
COPPERCLAD
GROUND ROD
PER SPECIFICATION
SECTION 26 0526
EXOTHERMIC CONNECTION
PARALLEL SPLICER
BIMETAL SPLICER
EXOTHERMIC
CONNECTION
COPPERCLAD
GROUND ROD
PER SPECIFICATION
SECTION 26 0526
EXOTHERMIC
CONNECTION
PARALLEL CABLE SPLICER
FLAT MOUNT POINT
BASE - ALUMINUM
14Ga 24St BARE ALUM CONDUCTOR
SOLID ALUMINUM
AIR TERMINAL
FINAL THRU-ROOF FLASHING
BY ROOFING CONTRACTOR
PVC SLEEVE TO BE FURNISHED
AND INSTALLED BY ELECTRICAL
CONTRACTOR
27 (1") PVC PIPE CAP
203mm
(8" MAX.)
THRU ROOF CONNECTOR
32Ga 17St BARE
CU CONDUTOR
13mm (1/2") STAINLESS
NUT AND WASTER
13mm (1/2") STAINLESS
STEEL RISER
SR
*** DISTANCE TO HIGHEST OPERABLE PART OF EQUIPMENT
72"** CIRCUIT BREAKER PANEL
ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED. DEVICES INDICATED AT 48" MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 48". DEVICES MAY BE INSTALLED IN
CONCRETE MASONRY UNITS WITH THE TOP OF THE DEVICE AT 48".
** DISTANCE TO TOP OF EQUIPMENT OR DEVICE
72"**
72"**
T1
POWER OR DISTRIBUTION PANEL
TRANSFORMER (TYPE DENOTED)
SPECIAL CABINET (TYPE DENOTED)
HT AFF SYMBOL
GROUND CONNECTION - EXOTHERMIC WELD
GROUND CONNECTION TO STEEL OR STRUCTURE
GROUND ROD (PLAN VIEW)
DESCRIPTION
**** DISTANCE BELOW CEILING
ANTENNA
***** DISTANCE TO BOTTOM OF DEVICE
CONDUIT TRANSITION DOWN
CONDUIT TRANSITION UP
CONDUIT EXPOSED
SURFACE RACEWAY
CONDUIT STUBBED OUT
CONDUIT CONCEALED BELOW FLOOR
CONDUIT CONCEALED IN WALL OR OVERHEAD
LIGHTNING PROTECTION CONDUCTOR SPLICE
ELECTRICAL SYMBOL LEGEND
LIGHTNING PROTECTION AIR TERMINAL (TYPE DENOTED)
AIR TERMINAL SCHEDULEAIR TERMINAL SCHEDULEAIR TERMINAL SCHEDULEAIR TERMINAL SCHEDULE
FILE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT TITLE:
COPYRIGHT 2009 BY LHB, INC. ALL RIGHTS RESERVED
http://www.LHBcorp.com
21 W. Superior Street Suite 500 Duluth, MN 55802
TEL 218/727-8446
FAX 218/727-8456
DULUTH MINNEAPOLIS
I HEREBY CERTIFY that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota.
Signature:
Typed or Printed Name:
Date: Reg. No.:
THIS SQUARE APPEARS 1/2"x1/2" ON FULL SIZE SHEETS
CLIENT:
133RD AW
MPLS / ST.PAUL IAP
QJKL 072919
133RD AW, ST. PAUL, MN
03-05-10 TYPE B 100%
C
R e vi t
Lo c a l F ile s
B ld g
E le c tr ic a l M E P n tr a lw lw e d a n .r vt
:1 :3
P M
WLW
LRH
090292
E7.01
ELECTRICAL
DETAILS
REPAIR ROOF
BUILDING 662
JOHN TOWNSEND
4036003-05-10
MINNESOTA AIR
NATIONAL GUARD
1 : 11
COPPER AIR TERMINAL DETAIL
1 : 12
FLAT ROOF AIR TERMINAL INSTALLATION DETAIL
1 : 13
GROUND CONDUCTOR SPLICING & WELDING DETAIL
1 : 14
MECHANICAL EQUIPMENT AIR TERMINAL INSTALLATION DETAIL
1 : 15
ROOF CABLE PENETRATION DETAIL
TYPE DESCRIPTION MANUFACTURER MODEL
CU-P 610mm (24") COPPER AIR TERMINAL MOUNTED ON STANDOFF PARAPET BASE THOMSON 572E
678LA
CU-F 610mm (24") COPPER AIR TERMINAL MOUNTED ON FLAT BASE. THOMSON 572E 688C
AL-S 610mm (24") ALUMINUM AIR TERMINAL MOUNTED ON SWIVEL BASE. THOMSON A571 A30
AL-M 610mm (24") ALUMINUM AIR TERMINAL MOUNTED ON MECHANICAL EQUIPMENT.
PROVIDE BIMETAL MECHANICAL EQUIPMENT BASE 702 WHERE APLICABLE
THOMSON A571
A611
| 090292 G001 030510 |
| 090292 A221 030510 |
| 090292 A222 030510 |
| 090292 E2-01 - ELECTRICAL PLAN |
| 090292 E7-01 - ELECTRICAL DETAILS |