This document provides specifications for plastic toilet compartments for a barracks restoration project at Camp Atterbury in Indiana. The project includes installing solid plastic toilet compartments and shower enclosures made of high-density polyethylene with eased edges and a consistent color throughout. Compartments must meet 2010 ADA standards and include stainless steel pilaster shoes, brackets, hinges, latches, coat hooks, and bumpers. Overhead bracing is also required. Bids are due by September 9, 2020 for this project with a contract duration of 240 days. The solicitation is set aside 100% for small businesses with a size standard of $39.5 million in average annual receipts. The North American Industry Classification for this project is 236220.

View the file

Other files for this federal contract opportunity

Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLASTIC TOILET COMPARTMENTS 102113.19 - 1

Camp Atterbury JMTC DLZ Project No. 1963-1020-90

BOQ and Barracks Renovation State of Indiana Project 2020-008

SECTION 102113.19 - PLASTIC TOILET COMPARTMENTS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary

Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Solid-plastic toilet compartments configured as toilet enclosures and shower enclosures.

1.3 ACTION SUBMITTALS

A. Product Data:

1. Solid-plastic toilet compartments:

a. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for toilet compartments.

B. Shop Drawings: For solid-plastic toilet compartments.

1. Include plans, elevations, sections, details, and attachment details.

2. Show locations of cutouts for compartment-mounted toilet accessories.

3. Show locations of centerlines of toilet fixtures.

4. Show locations of floor drains.

C. Samples for Initial Selection: Manufacturer's standard color sheets, showing full range of available colors for each type of toilet compartment material indicated.

1. Include Samples of hardware and accessories involving material and color selection.

D. Samples for Verification: Actual sample of finished products for each type of toilet compartment indicated.

1. Size: Manufacturers? standard size.

2. Include each type of hardware and accessory.

PLASTIC TOILET COMPARTMENTS 102113.19 - 2

Camp Atterbury JMTC DLZ Project No. 1963-1020-90

BOQ and Barracks Renovation State of Indiana Project 2020-008

1.4 CLOSEOUT SUBMITTALS

A. Maintenance Data: For toilet compartments.

1.5 FIELD CONDITIONS

A. Field Measurements: Verify actual locations of toilet fixtures, walls, columns, ceilings, and other construction contiguous with toilet compartments by field measurements, and coordinate before fabrication.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Regulatory Requirements: Comply with applicable provisions in the U.S. Department of Justice

"2010 ADA Standards for Accessible Design" and ICC A117.1 for toilet compartments designated as accessible.

2.2 SOLID-PLASTIC TOILET AND SHOWER COMPARTMENTS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Accurate Partitions Corp., an ASI Group Company.

2. AJW Architectural Products.

3. Global Partitions Corp., an ASI Group Company.

4. Scranton Products.

B. Toilet and Shower-Enclosure Style: Overhead braced.

C. Door, Panel, and Pilaster Construction: Solid, high-density polyethylene (HDPE) panel material, not less than 1 inch thick, seamless, with eased edges, and with homogenous color and pattern throughout thickness of material.

1. Color and Pattern: One color and pattern in each room as selected by Architect from manufacturer's full range.

D. Pilaster Shoes and Sleeves (Caps): Manufacturer's standard design; polymer or stainless steel.

1. Polymer Color and Pattern: Matching pilaster.

E. Brackets (Fittings):

1. Full-Height (Continuous) Type: Manufacturer's standard design; polymer or extruded aluminum.

a. Polymer Color and Pattern: Matching panel.

PLASTIC TOILET COMPARTMENTS 102113.19 - 3

Camp Atterbury JMTC DLZ Project No. 1963-1020-90

BOQ and Barracks Renovation State of Indiana Project 2020-008

2.3 HARDWARE AND ACCESSORIES

A. Hardware and Accessories, Heavy Duty: Manufacturer's heavy-duty operating hardware and accessories.

1. Hinges: Manufacturer's minimum 0.062-inch-thick stainless steel continuous, cam type that swings to a closed or partially open position, allowing emergency access by lifting door. Mount with through bolts.

2. Latch and Keeper: Manufacturer's heavy-duty, surface-mounted, cast-stainless steel latch unit, designed to resist damage due to slamming, with combination rubber-faced door strike and keeper, and with provision for emergency access. Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible. Mount with through bolts.

3. Coat Hook: Manufacturer's heavy-duty combination cast-stainless steel hook and rubber-tipped bumper, sized to prevent inswinging door from hitting compartment-mounted accessories. Mount with through bolts.

4. Door Bumper: Manufacturer's heavy-duty, rubber-tipped, cast-stainless steel bumper at outswinging doors. Mount with through bolts.

B. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with antigrip profile and in manufacturer's standard finish.

C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel, finished to match the items they are securing, with theft-resistant-type heads. Provide sex-type bolts for through-bolt applications. For concealed anchors, use stainless steel, hot-dip galvanized steel, or other rust-resistant, protective-coated steel compatible with related materials.

2.4 MATERIALS

A. Aluminum Castings: ASTM B26/B26M.

B. Aluminum Extrusions: ASTM B221.

2.5 FABRICATION

A. Fabrication, General: Fabricate toilet compartment components to sizes indicated. Coordinate requirements and provide cutouts for through-partition toilet accessories where required for attachment of toilet accessories.

B. Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling mechanism, and anchors at pilasters to suit floor conditions. Provide shoes at pilasters to conceal supports and leveling mechanism.

C. Door Size and Swings: Unless otherwise indicated, provide 24-inch-wide, inswinging doors for standard toilet compartments and 36-inch-wide, outswinging doors with a minimum 32-inch-wide, clear opening for compartments designated as accessible.

PLASTIC TOILET COMPARTMENTS 102113.19 - 4

Camp Atterbury JMTC DLZ Project No. 1963-1020-90

BOQ and Barracks Renovation State of Indiana Project 2020-008

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas and conditions, with Installer present, for compliance with requirements for fastening, support, alignment, operating clearances, and other conditions affecting performance of the Work.

1. Confirm location and adequacy of blocking and supports required for installation.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION OF PLASTIC TOILET COMPARTMENTS

A. General: Comply with manufacturer's written installation instructions. Install units rigid, straight, level, and plumb. Secure units in position with manufacturer's recommended anchoring devices.

1. Maximum Clearances:

a. Pilasters and Panels: 1/2 inch.

b. Panels and Walls: 1 inch.

2. Full-Height (Continuous) Brackets: Secure panels to walls and to pilasters with full-height brackets.

a. Locate bracket fasteners, so holes for wall anchors occur in masonry or tile joints.

b. Align brackets at pilasters with brackets at walls.

B. Overhead-Braced Units: Secure pilasters to floor and level, plumb, and tighten. Set pilasters with anchors penetrating not less than 1-3/4 inches into structural floor unless otherwise indicated in manufacturer's written instructions. Secure continuous head rail to each pilaster with no fewer than two fasteners. Hang doors to align tops of doors with tops of panels and adjust, so tops of doors are parallel with overhead brace when doors are in closed position.

3.3 ADJUSTING

A. Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's written instructions for proper operation. Set hinges on inswinging doors to hold doors open approximately 30 degrees from closed position when unlatched. Set hinges on outswinging doors to return doors to fully closed position.

END OF SECTION 102113.19