20210528 - QandA.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
XCTC TNARNG Base Life Support Federal contract opportunity
Solicitation number
W912L7-21-Q-1501
Issued by
Department of the Army Tennessee Army National Guard

About this file

This document contains a request for proposal for base life support services at multiple locations in Fort Hood, Texas. The Tennessee Army National Guard is seeking a turnkey solution including sleeping tents, feeding tents, catered meals, gray water removal, potable water, dumpsters, power generation, laundry, shower, and latrine trailers. Proposals are due by May 31, 2021 and will be evaluated using lowest price technically acceptable criteria. The contract will be a firm-fixed price award. The North American Industry Classification System code for this requirement is 521610 for facility support operations, and it is set aside for small businesses.

View the file

Other files for this federal contract opportunity

Other files attached to XCTC TNARNG Base Life Support, newest first.
File Type Posted
20210528 - Dumpster Schedule.xlsx XLSX spreadsheet
20210528 - TNARNG XCTC PWS.docx DOCX document
20210527 - 278 Latrines-HW Stations Schedule.xlsx XLSX spreadsheet
20210527 - TNARNG XCTC PWS.pdf PDF
20210527 - QandA.xlsx XLSX spreadsheet
20210527 - TNARNG Requirement Timeline.xlsx XLSX spreadsheet
20210521_TNARNG_XCTC_PWS.pdf PDF
20210519 - TNARNG XCTC PWS.pdf PDF
TNARNG Requirement Timeline 20210519.xlsx XLSX spreadsheet
Combined Synopsis Solicitation 2021 XCTC 20210519.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 Job #: 2656 Solicitation Title: TNARNG - XCTC Ft. Hood Due Date: 9amCT - May 26th 2021 POC Submitting Questions: Marcus Deem

Q #RFP Section,
Page NumberPosted QuestionAnswer
15.1 & 5.2 Page 10Provide a desired ratio for number of users to laundry units?50 Soldiers per washer/dryer.
25.1 & 5.2 Page 10Can laundry facilities use other than trailer type structures?Yes, tents and containerized facilities are acceptable so long as they have at minimum 1 inch flooring.
35.3 & 5.4Do the shower trailers need daily cleaningYes
45.5 Page 12Can Latrine facilities use other than trailer type structures?Yes, tents and containerized facilities are acceptable so long as they have at minimum 1 inch flooring.
55.5.1 Page 12What is the ratio of toilets per soldier?1 per 15 Soldiers
65.5.1 Page 12What is the ratio of hand washing stations per soldier1 per 100 soldiers
75.10.1 Page 14Section States: "Contract shall provide sufficient mobile refrigeration (Reefer) capability to support 13,440 cubic feet of total required storage capacity at minimum of fourteen separate locations." - Please provide the minimum number of cubic feet per location so we may understand the number of reefer units required.1600 cubic feet per location. Total should be 22,400. PWS and solicitation will be updated.
85.10.3 Page 14Section States: "Requesting activity is responsible for all re-fueling required during the period of performance." - Please confirm if Government personnel will be maintaining the refueling needs for refrigerated trucks.The requiring activity will operate and refuel the reefer trucks.
95.11 & 5.12 Page 15Will the contractor be required to supply cots?Contractor will not supply cots.
105.11 & 5.13 Page 15/16Can you provide any additional information for the site prepartions required for tent construction? Is the ground grass, asphault, dirt? (Will a flat surface be designated for tent construction?)At TA-40 and 60, ground will be relatively flat with a mix of dirt and grass.
115.12.13 Page 15/16Please provide the anticipated male to female ratio for the required training areas; TA-40, TA-60 and N. Ft. Hood.230th SB Ratios: @ TA-40 80% males/20% females @ TA-60 70% males/30% females 278th ACR Ratio: 95% males/5% females
125.14.1 Page 15/16Please provide the square foot required per soldier for the sleeping tents.50 Square foot per Soldier
135.13.1 & 5.14.1 Page 16Please confirm the requirement for wind load rating for the feeding tent is to be 85mph and the sleeping tent is to be rated at 75mph. (Typical max wind load rating for clearspan billeting is 75mph.)75 MPH
145.15.3 Page 17Breakfast meal requirements state: minimum 8 oz meat serving, Dinner meal requirements state: minimum 4 oz meat serving. This is the reverse of the typical requirement and industry standards. Request confirmation that this is intentional and 8 oz meat servings is indeed required for breakfast and a 4 oz meat serving for dinner.This is a clerical error. 8 oz minimum for dinner and 4 oz for breakfast.
155.15.6 Page 17Section States: "Contractor must be locally certified by health inspectors prior to contract execution." Is a local Texas food handler's permit required? or would a nationally recognized food protection manager certification via ServSafe be acceptable?National recognition would be acceptable.
165.18.1 Page 18Section States: "Access to fuel will be provided." - Please advise if transportation and fueling of generator power is to be performed by contractor or government personnel.Transportation and fueling of contracted items (except Reefer trucks) will be the responsibility of the Contractor. Government personnel will provide access to fuel point. No charge for the fuel to the Contractor.
175.22 Page 19Please provide toilet locations and Approximately how many total separate locations will there be toilet and handwashing units required.278th Latrines-HW Stations Schedule will be attached to the solicitation and include the information.
185.3.1How many shower heads per pax (ratio of shower heads per pax for males and females).16 Soldiers per shower head
195.4.1How many shower heads per pax (ratio of shower heads per pax for males and females).16 Soldiers per shower head
205.6.1 and 5.7.1IS there a requirement for the 278th SB to have Latrine Trailers?No
215.6.1 and 5.7.1Trash Removal and Dumpsters - Do you have a formula or ratio for the size and service frequency for trash removal.See spreadsheet for Dumpster Schedule
225.8 and 5.9Does the Unit provide the Potable Water Blivets?Contractor must supply potable water storage sufficient for the contracted items (laundry, shower, etc)
23Does the 230th SB have a requirement for Reefer trucks?No
24Shower TrailerWill potable water be supplied by the requiring activity for contracted items?Access points will be provided and Contractor will be escorted to the points.
255.3 & 5.41. Can the USG define soaps and paper products or give examples?HAND SOAPS , DAIL HANDY SOAP ANTIBACTERIAL LIQUID WITH DISPENSER brown papper towel for drying hands ex. Georgia Pacfic multifold towel.
265.3 & 5.4a. Will the paper products need to be gender specific?No
275.3 & 5.4If gender specific what is the ratio or percentage?NA
28Will gray water removal be required for contracted items?For contracted items. Contractor will be responsible for the storage and removal of graywater to the appropriate dump site on Fort Hood (no fee for dumping gray water). COR will coordinate with the Contractor for dump sites and hours.
295.18 & 5.19If Pole or shore power what is the volts/amps 3phase and seize generator?Should be sufficient to support contracted items. Must also allow for power strips and outlets for tents.
305.5Do the latrine trailers need daily cleaningYes
31Not SpecifiedAre light towers requiredLight Towers are not included in this solicitation. See solicitation W912L7-21-Q-1504. Solicitation endd 1JUN21 @ 1400 CST.
325.10What is the reefer truck requirement prior to the arrival of the 278th ACR?3200 cubic feet at two separate locations.