QUESTIONS__ANSWERS_-_1 2 15 16 34_-_W912L2-16-B-2001_-_RPR_Main_Gate_(Valencia_Gate)_-_22Jun.pdf

PDF 195 KB Posted

Attached to
RPR MAIN GATE (VALENCIA GATE) 162ND WING.
Solicitation number
W912L2-16-B-2001
Issued by

About this file

Questions and Answers 1 2 15 16 34

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUESTIONS AND ANSWERS

W912L2-16-B-2001 – RPR Main Gate (Valencia Gate)

22Jun16

Q1. Keynotes 1, 9, 10, 11, 13, 14, 15, 16, 17, and 18 on Detail 1/g2.0 are not shown on the Keynote

Legend. Please provide the information for the missing Keynotes.

A1.

1. A1. Hinge Post Assembly

2. Hinge End Top Plate Assembly.

3. Not used.

4. Shaft Collar

5. Pillow block

6. Not Used

7. Not Used

8. Not Used

9. Not Used

10. Not Used

11. Latch Post Assembly

12. Manual Latch Pin

13. Cable Eye Cushion

14. Not Used

15. Not Used

16. Not Used

17. Yoke assembly with Tube Clamps

18. Crash Cable Assembly

19. Crash Tube

20. Tape, Red Reflective

Q2. Keynotes 2, 3, 4, and 5 on the Keynote Legend on Detail 1/g2.0 do not appear to correspond to the

Keynotes on the Detail. Is the Keynote Legend correct?

A2. These are General Notes, not keynotes.

Q15. C2.0 note 9 calls to relocate the light pole, please provide a structural detail for the pole base.

A15. See Attached detail.

Q16. Please provide the structural requirements for the CMU columns on the relocated monument sign.

Please include architectural details also.

A16. CMU piers shall be 16”x16” with 4-#5 rebar, one each cell. Provide #2 pencil rod ties at 16” o.c.

vertical. Provide 12” thick x 3’wide x 10’-0” long concrete footing reinforced with 4-#5 x cont.

reinforcing long dimension with #4 cross reinforcing at 24” o.c. perpendicular. Relocate existing marquee sign and support beams. Extend existing power to new sign.

Q34. The Light Pole Detail on Sheet e001 says to “See Structural Details for Additional Information” and to “See Structural Calculations for More Information”. There are no Structural Drawings in the set.

Please provide the missing information.

A34. See attached detail.

File details come from the government source that posted it. Updated .