CNC Machines Questions.docx

DOCX document 16 KB Posted

Attached to
CNC Milling and Lathe Machine Federal contract opportunity
Solicitation number
W912K625QA016
Issued by
Department of the Army Maryland Army National Guard

About this file

The file is a document containing technical questions about CNC machine installation for the Maryland Army National Guard's Allied Trades Shop. The questions cover critical infrastructure and equipment details, including air compressor availability (10-20 feet from installation), primary power accessibility (10-20 feet from machine install area), and facility ventilation requirements. The government indicated they do not currently have a mist collector system and would be interested in one if feasible.

The document relates to Solicitation W912K625QA016 for procuring two CNC machines: a CNC Lathe and a CNC Vertical Milling Machine, to be delivered to 333 Old Bay Lane, Havre de Grace, Maryland within 90 days. Vendors must submit detailed proposals by 3:00 PM Eastern Standard Time on September 19, 2025, including company information, pricing, spec sheets, and UEI number. Submission is via email to cory.l.silfies.civ@army.mil, with vendors required to be registered in the System for Award Management (SAM). The machines will be used for machining aluminum, mild steel, stainless steel, and brass.

View the file

Other files for this federal contract opportunity

Other files attached to CNC Milling and Lathe Machine, newest first.
File Type Posted
Solicitation - W912K625QA016.pdf PDF
SOW CSMS Allied Trades CNC Machines.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CNC Machines Questions

1. Air Compressor – Does the facility currently have an air compressor available for machine hookup? If so, please confirm the distance from the proposed installation location.

1. Yes, approximately 10-20ft

1. Primary Power – Please confirm whether primary power is available at the installation location. If so, what is the approximate distance from the machine install area to the nearest power supply?

1. Yes, approximately 10-20ft

1. Ventilation / Mist Collector – While not specifically required in the solicitation, can you confirm whether the facility has an existing mist collector system, or if the government would like one included as part of this installation?

1. We do not have a mist collector system in the building.

1. Option CLIN Quote: Yes, we would be interest if feasible and available.

1. Coolant Type / Metal Material – Please confirm the type of coolant required. Alternatively, please provide the primary metal(s) being cut so that we may determine the appropriate coolant type.

1. Aluminum, Miled Steel, Stainless Steel, Brass

File details come from the government source that posted it. Updated .