This document contains questions and answers regarding solicitation number W912K623Q0047 for Intrusion Detection System Statewide Monitoring Services. The solicitation is from the Department of the Army Maryland Army National Guard and seeks quarterly inspection of 14 motion detectors and 2 door contacts in a SCIF. It also requires reprogramming of alarm points on 32 panels to update the internal account number, 800 number for contact monitoring, and reregistration of backup cell units with the new monitoring company. The questions clarify that while the administration codes for each panel are needed, the Maryland Electronic Security System technicians already have the current codes to facilitate the reprogramming process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Question and Answers 8-29-2023.pdf | ||
| Solicitation -W912K6-23-Q-0047 IDS Monitoring.pdf | ||
| MD State Monitoring_PWS AUG_2023.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W912K6‐23‐Q‐0047 Intrusion Detection System Statewide Monitoring Services
Question and Answers 2
1. How many alarm points are there in the SCIF that require quarterly inspection?
ANS: The alarm points which require inspections are the 14 motion detectors and 2 door contacts.
2. How many alarm points on each of the 32 panels must be reprogrammed?
ANS: The internal account number and the 800 number that the system will use to contact monitoring will be changed during the reprogramming process. The backup cell units will also be reregistered by the new monitoring company.
3. Requesting clarity on the answer to question 3 (Previous Q&A)
Does the Government have the admin codes for each panel to reprogram them, or will the panels be reprogrammed from scratch?
Ans: Both. The Admin Codes are needed to start the programming process but are changed during the programming process to a code selected by the Maryland Electronic Security System
(MDESS) Techs.
Q: Does this mean that the Maryland Electronic Security System Techs already have what the codes are now, or will the monitoring company have to completely reprogram each panel from scratch, including all of the zones, to create new codes?
ANS: The Maryland Electronic Security technicians currently have all the require codes.