W912HV-20-B-0013-AM0001 Revised Drawings.pdf
PDF 9 MB Posted
- Attached to
- AFSOC103010 Simulator Facility, Yokota AB, Japan
- Solicitation number
- W912HV-20-B-0013
About this file
This solicitation describes a commercial and institutional building construction project. The project involves constructing an 845 square meter Simulator Facility at Yokota Air Base in Japan, including a concrete foundation and floor slab, concrete walls and roof slab, steel structure, metal roofing, fire safety systems, and support facilities. Interested local Japanese firms must be registered in the System for Award Management and submit documentation proving registration with the Government of Japan to perform construction and hold necessary licenses by the bid submission deadline. The solicitation will utilize full and open competition and award a firm fixed price contract to local Japanese sources.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
X
X
X
X
X
X
X
GATE 20
N : 3959240.006
E : 350593.694
JPG-1
N : 3959286.831
E : 350547.881
TG-1
N : 3959289.072
E : 350559.459
GATE 10
N : 3959326.169
E : 350581.891
C
O
C
O
C
O
C
O
C
C
C
O
C
C
C
O
C
O
C
O
C
O
C
O
C
O
C
O
C
O
C
O
W
V
W
V
C
O
S
I G
N
P
O
S
T
S
I G
N
P
O
S
T
F
H
S
I G
N
P
O
S
T
S
I G
N
P
O
S
T
S
I G
N
P
O
S
T
C
O
S
I G
N
B
O
A
R
D
S
I G
N
P
O
S
T
C
O
C
O
C
O
T
E
M
P
S
O
I L
Y
A
R
D
T
E
M
P
S
O
R
D
T
E
M
P
S
O
R
D
T
E
M
P
S
O
R
D
S
I G
N
P
O
S
T
W
V
W
V
W
V
C
O
F
H
W
V
A
S
A
S
A
S
W
V
W
V
W
V
A
S
A
S
A
S
A
S
C
O
C
O
C
O
C
O
W
V
SIGNBOARD
C
O
C
O
C
O
A
S
A
S
C
O
F
H
W
V
W
V
W
V
W
V
F
H
C
O
W
V
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
W
V
W A
T E
R
V
A L V
EC
O
P
I P
E
P
I P
E
S
E
N
S
O
R S
E
N
S
O
R
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
S
I G
N
B
O
A
R
D
T
V
T
V
C
O
A
SA
S
A
S
C
O
C
O
C
O
S
I G
N
B
O
A
R
D
C
O
C
O
C
O
C
O
T
V
S
I G
N
B
O
A
R
D
P
I P
E
C
O
C
O
C
O
C
O
C
O
C
O
S
I G
N
B
O
A
R
D
S
I G
N
B
O
A
R
D
C
O
W
V
G
S
P
100GSP
100GSP
100GSP
G
S P
70GSP
P
V
C
P
P
V C
P
P
V C
P
150CIP
150CIP
150CIP
C
I
P
C
IP
19PVCP
A
S
PROTECTION PILLAR
S
I G
N
B
O
A
R
D
G
A
T
E
F
L
A
S
H
L
I G
H
T
S
I G
N
B
O
A
R
D
U
N
D
E
R
C
O
N
S
T
R
U
C
T
I
O
N
U
N
D
N
S
T
R
U
C
T
I O
N
U
N
D
N
S
T
R
U
C
T
I
O
N
U
N
D
N
S
T
R
U
C
T
I
O
N
U
N
D
N
S
T
R
U
C
T
I O
N
S
E
N
S
O
R S
E
N
S
O
R
T
V
F
U
B
X
F
U
X
C
O
C
O
C
O
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
A
S
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K H
O
O
K
H
O
O
K
H
O
O
K H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
W
H
EEL S
TO
P
C
O
C
O
C
O
A
S
A
S
A
S
A
S
A
S
A
S
A
S
C
O
C
O C
O
C
O
C
O
C
O
C
O
C
O
C
O
D
IE
S
E
L
T
A
N
K
A
W V
F
U
V
L
V
E
C
O
C
O
SERVICEABLE
W
V
W
V
W
V
C
O
C
O
C
O
C
O
C
O
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
H
O
O
K
S
I G
N
P
O
S
T
S
I G
N
B
O
A
R
D
S I G
N B
O A
R D
F H
F
H
F
H
C
P
T
E
S
T
C
P
T
E
S
T
C
P
T
E
S
T
C
O
C
O
C
O
C
O
W
V
F
H
W
V
S
IG
N
B
O
A
R
D
S
IG
N
B
O
A
R
D
W
V
D
I P
D
I P
D
I P
120DIP
90DIP
120DIP
D
I P
D
I P
90DIP
S H
O W
E R
D
I P
S I G
N B
O A
R D
DIE
SEL
TANK
S
I G
N
B
O
A
R
D
C
O
C
O
C
O
C
O
C
O
W x
X
X
C
O
X
F
F
F
F
F
F
F
F
F
F
F
F
F
G
G
H-2
H-3
H-1
G
G
G
G
G
J
J
G
G
J
J
G
G
G
J
G
G
J
J
G
G
G
G
G
H-4
G
F
F
F
F
L
O
R
I N
G
R
M
O
R
G
S
T
DAVIS ST
B E
N N
E T
T U
N N
ANDREWS DR
S P
A A
Z
F R
I E
N D
S H
P
V
D
S
E
B
I
L
C
H
E
L
I
A
V
E
CARSWELL ST
ANDREWS DR
C R
A B
B A
V E
D E
S E
V E
R S
K
VANCE ST
R I C
K E
N B
A C
K E
R
S
T
V
O
S
L
WALKER BLVD
M
IC
H A
E L D
R
C R
A B
B A
V E
C R
A B
B A
V E
M
O
R
G
HOWARD ST
W
A
L
M
S
L
T U
N N
HOWARD ST
T U
N N
S
E
L
F
R
I
D
G
E
W I L
K I N
S
S
T
AIRLIFT AVE
CASTLE ST
S
IJ
A N
D R
B O
C
H
E
L
I
A
V
E
ARNOLD DR
CARSWELL ST
VANCE ST
ANDREWS DR
B A
K E
R
S
T
WALKER BLVD
S
A
R
N
O
S
K
I
A
V
E
T W
I N
I N
G
S
T
T W
I N
I N
G
S
T
V A
N D
E N
B E
W
A
L
M
S
L
S P
A A
S
E
L
F
R
I
D
G
E
D E
S E
V E
R S
T
R
U
E
M
P
S
IJ
A N
D R
T W
I N
I N
G
S
T
DAVIS ST
B O
WALKER BLVD
COCHRAN
H A
U G
H T
MCGUIRE AVE
M
C G
U I R
E
A
V E
A
I R
L I F
E
B A
K E
R
S
T
H A
U G
H T
W
A
L
K
V
D
S P
A A
S
H
O
M
D
S
E
B
I
L
L
A
H
M
P
E
A
S
IJ
A N
D R
A
LA
B A
M A
A V
E
F R
I E
N D
S H
V
D
A
I R
L I
E
E A
K E
R
S
T
S
IJ
A N
D R
A
LA
B A
M A
A V
E
C A
R S
W E
AIRLIFT AVE
S
A
R
N
O
S
K
I
A
V
E
WALKER BLVD
W
A
L
K
V
D
HAMILTON ST
M
O
R
G
MITCHELL RD
W
A
L
K
V
D
W I L
K I N
S
S
T
WALKER BLVD
GOETTLER ST
F R
I E
N D
S H
V
D
HAMILTON ST
AIRLIFT AVE
DAVIS ST
S
A
R
N
O
S
K
I
A
V
E
C R
A B
B A
V E
J
O
N
E
WALKER BLVD
WALKER BLVD
M C
G U
I R
E
A
V E
F R
I E
N D
S H
V
D
WALKER BLVD
P
U
C
K
E
T
W
A
L
M
S
L
MITCHELL RD
J
O
N
E
C
H
E
L
I
A
V
E
C
H
E
L
I
A
V
E
M
C G
U I R
E
A
V E
S
I
J
S P
A A
F O
U L O
S
I
J
H A
U G
H T
C A
R S
W E
L
A
H
M
J
O
N
E
ANDREWS DR
E A
R H
A R
T A
V E
M
E
Y
E A
K E
R
S
T
S
H
O
VANCE ST
T U
N N
T U
N N
W
A
L
K
V
D
M C
G U
I R
E
A
V E
E A
K E
R
S
T
S
E
B
I
L
S
E
L
F
R
I
D
G
E
D E
S E
V E
R S
B
R
O
W
E
W I L
K I N
S
S
T
AIRLIFT AVE
MITCHELL RD
MCGUIRE AVE
M C
G U
I R
E
A
V E
COCHRAN
S P
A A
R I C
K E
N B
A C
K E
R
S
T
F O
U L O
H
U
G
H
MITCHELL RD
DAVIS ST
M
IC
H A
E L D
R
DAVIS ST
AIRLIFT AVE
L
O
R
I
R
M
O
R
G
B O
DAVIS ST
P
U
C
K
E
T
S
H
O
A
LA
B A
M A
A V
E
HOWARD ST
S
M
I
H
W
A
L
K
V
D
H A
U G
H T
T W
I N
I N
G
S
T
HAMILTON ST
AIRLIFT AVE
S
I
J
ARNOLD DR
J
O
N
E
M
I T
C H
E L L
R
D
HOWARD ST
S
E
L
F
R
I
D
G
E
W I L
K I N
S
S
T
M
E
Y
P
U
C
K
E
T
W
A
L
K
V
D
WALKER BLVD
ARNOLD DR
C A
R S
W E
M
IC
H A
E L D
R
V
O
S
L
H
U
G
H
A
LA
B A
M A
A V
E
H
U
G
H
D E
S E
V E
R S
V A
N D
E N
B E
S
A
R
N
O
S
K
I
A
V
E
A
I R
L I
E
VANCE ST
F O
U L O
T U
N N
CARSWELL ST
T
R
U
E
M
P
S
M
I
E A
R H
A R
T A
V E
V A
N D
E N
B E
M
I T
C H
E L L
R
D
R I C
K E
N B
A C
K E
R
S
T
T U
N N
M
IC
H A
E L D
R
V
O
S
L
V
O
S
L
E A
K E
R
S
T
W
A
L
M
S
L
B
R
O
E
S
M
I
AIRLIFT AVE
GOETTLER ST
L
A
H
M
B
R
O
E
B A
K E
R
S
T
WALKER BLVD
P
E
A
B O
S P
A A
M
E
Y
GOETTLER ST
V A
N D
E N
B E
CARSWELL ST
DAVIS ST
ARNOLD DR
E A
R H
A R
T A
V E
W
A
L
K
V
D
P
E
A
COCHRAN
S P
A A
S
E
B
I
L
C A
R S
W E
T U
N N
M C
G U
I R
E
A
V E
M
C G
U I R
E
A
V E
WALKER BLVD
B
R
O
E
T
R
U
E
M
P
L
O
R
I
R
S
M
I
R I C
K E
N B
A C
K E
R
S
T
DAVIS ST
CASTLE ST
H
U
G
H
M
I T
C H
E L L
R
D
GOETTLER ST
B A
K E
R
S
T
COCHRAN
P
E
A
F O
U L O
CASTLE ST
M
C G
U I R
E
A
V E
MCGUIRE AVE
HAMILTON ST
A
I R
L I
E
L
O
R
I
R
AIRLIFT AVE
MCGUIRE AVE
CASTLE ST
S P
A A
M
E
Y
T
R
U
E
M
P
WALKER BLVD
W
A
L
K
V
D
L
A
H
M
S
I
J
P
U
C
K
E
T
E A
R H
A R
T A
V E
M
I T
C H
E L L
R
D
S
H
O
W I L
K I N
S
S
T
N
A
N
A
N
A
N
A
N A
N
A
N
A
N
A
N
A
N
A
N
A
N
A
N
A
X
N
A
N
A
N
A
N
A
N
A
N
A
N
A
AIRLIFT AVE
A
R
N
O
X X
X X
X
X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
N : 3957342.529
E : 351348.329
N : 3957447.837
E : 351230.880
X X X X X X X
X X X
X
X
X
X
JPG-2
N : 3957875.636
E : 350883.528
TG-2
N : 3957787.699
E : 350923.240
TG-3
N : 3957918.558
E : 351137.698
JPG-3
N : 3957904.069
E : 351139.670
TG-4
N : 3957758.269
E : 351212.918
JPG-4
N : 3957174.676
E : 351495.798
JPG-5
N : 3957445.385
E : 351453.810
JPG-6
N : 3958981.162
E : 350712.653
SHEET ID
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
U
M
Y
C
O R
E
N G
I N
E E
R S
C H
E C
K E
D
B
Y
US Army Corps of Engineers ®
I S
O
A
A
D R
A W
I N
G
C
O D
E
PLOT SCALE:PLOT DATE:
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N
D
I S
T R
I C
T
A P
O
A
P
F Y
L
C O
N
A
F S
O C
S I M
U L
A T
C
I L
I T
Y
Y O
K O
S
E
J A
P A
N
S I M
U L
A T
I L
D I N
G
W
H V
D
A F
S C
O C
G
A
M E
N D
D
W G
A F
R
12/4/201910:10:00PM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
M A
S
C R
I P
T I O
N D
A T
E
R
K N
O L
L E
JACOBS GOVERNMENT SERVICES COMPANY
777 MAIN STREET
FORT WORTH, TX 76102 USA
GENERAL NOTES
LEGEND
TRUE NORTH
READY TO ADVERTISE - 06 MARCH 2020
S I T
E
L
O C
A T
I O
N
M
U
L
R
O U
T E
S
1. ALL GRUBBING AND CLEARING RESIDUE,
DEMOLISHED MATERIAL RUBBISH AND
DEBRIS GENERATED BY THIS PROJECT
SHALL BE HAULED OFFSITE TO AN
APPROVED LANDFILL
2. CONSTRUCTION WITHIN 61 METERS OF
FOXTROT TAXIWAY REQUIRES A MINIMUM
45-DAY COORDINATION NOTICE WITH THE
CONTRACTING OFFICER AND THE AIRFIELD
MANAGER. THE BASE IS NOT ALLOWED TO
FLY AIRCRAFT DURING 10:00PM AND
5:00AM DURING NORMAL OPERATIONS. THE
AIRFIELD MANAGER WILL ALLOW NIGHT
CONSTRUCTION TO MINIMIZE AIRCRAFT
OPERATIONAL IMPACTS.
3. "FY17 MILCON AFSOC103022 AIRFIELD
APRON AND SITE INFRASTRUCTURE" IS
SHOWN AS EXISTING CONDITIONS.
4. CONTRACTOR ACCESS FOR BUILDING
CONSTRUCTION AND SITE WORK SHALL BE
THROUGH GATES 7 AND 10.
5. IT IS ASSUMED THAT CONSTRUCTION OF
"FY17 MILCON AFSOC103022 AIRFIELD
APRON AND SITE INFRASTRUCTURE" WILL
COINCIDE IN TIME AND LOCATION WITH
THIS PROJECT. CONTRACTOR SHALL
COORDINATE WITH CONTRACTING
OFFICER AND "AIRFIELD APRON AND SITE
INFRASTRUCTURE" CONTRACTOR FOR
MATTERS INCLUDING, BUT NOT LIMITED TO,
SHARED LAYDOWN AREA, HAUL ROUTE,
AND SITE ACCESS.
TWO-WAY HAUL ROUTE
PROJECT BOUNDARY
T W
Y
C
T W
Y
C
T W
Y
D
T W
Y
D
T
W
Y
B
T
I
X
I W
A Y
G
O
L
F
G
O
L
F
J
U
L
I
E
T
FOXTROT TAXIWAY
RUNWAY 18-36
WALKER BLVD
W
A
L
K
V
D
M c G
U I R
E
A
V E
AIRLIFT AVE
A
I R
L
I
E
G-100
PROJECT SITE
FIRE STATION
FIRE STATION
BASE CIVIL ENGINEER
ID/PASS GATE
M A
T C
H
L I N
E
T
H
E
E T
M A
T C
H
L I N
E
T
H
E
E T
SCALE: 1:6000
0 120000 240000
T O
K Y
O
TRANSMITTER
BUILDING
KEYNOTES
1 : 6000
SITE LOCATION MAP AND HAUL ROUTES
T
A
X
I
L
A
N
E
T
A
X
I
L
A
N
E
T
A
X
I
L
A
N
E
R
I N
G
R
O
A
D
CONTRACTOR STAGING AREA
CONTRACTOR
STAGING AREA
A1
GATE 11
EXISTING FENCE LINE
GATE 10, GATE 20
TEMPORARY GATE (TG)
JOGGING PATH GATE (JPG)
R r
A
D D
T
E
L O
C A
T I O
N S
O
Y
R r
SEAL
JAMES D. EMERSON
62773
05-21-2020
SEAL
05-21-202009-25-2020
10/02/2020
TEXAS REGISTERED
ENGINEERING FIRM F-296
05-20509-
10/02/
(AM-0001)
SHEET ID
R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
C H
E C
K E
D
B
Y
US Army Corps of Engineers ®
I S
O
A
A
D R
A W
I N
G
C
O D
E
PLOT SCALE:PLOT DATE:
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N
D
I S
T R
I C
T
A P
O
A
P
F Y
L
C O
N
A
F S
O C
S I M
U L
A T
C
I L
I T
Y
Y O
K O
S
E
J A
P A
N
S I M
U L
A T
I L
D I N
G
W
H V
D
A F
S C
O C
C
U
D
W G
A F
R
12/4/201910:10:00PM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
M A
S
C R
I P
T I O
N D
A T
E
J
E
M E
R S
O N
A
F
E A
L Y
R
K
N O
L L
E
K
K
E N
N E
D Y
JACOBS GOVERNMENT SERVICES COMPANY
777 MAIN STREET
FORT WORTH, TX 76102 USA
READY TO ADVERTISE - 06 MARCH 2020
TEXAS REGISTERED
ENGINEERING FIRM F-2966
CU502
U T
I L
I T
Y
D
E T
A I L
S
Ø VARIES PVC Ø VARIES PVCØ VARIES-WYE PVC
EXISTING GRADE
CLEANOUT
Ø VARIES PVC STRAIGHT PIPE
THREADED OUTLET
CONC
COLLAR
ADJUSTABLE VALVE
BOX
C CROSS
OR TEE
L
VARIABLE
V A
R I E
S
GROUND
MIN.
CONCRETE FOOTING
GRADE SURFACE
25 CROWN
150 DIAMETER SCHEDULE
40 STEEL PIPE
75 DOME FILL POST
WITH CONCRETE
Ø300
(21 MPa)
NOTE
1. SLOPE CONCRETE COLLAR AWAY FROM HYDRANT
NTS
P
T H
EXISTING 150 GATE VALVE
EXISTING 150 PVC
2100 MAX
1000 MIN
FACE OF EXISTING CURB OR
EDGE OF EXST ROADWAY
CRUSHER-RUN
FILL
22575
600 x 600
CONC.
COLLAR
S
O
LOCK AND CHAIN
GROUND LINE
P
R O
X
450 SQUARE
ELEVATION
CONCRETE
ANCHOR BLOCK
(21MPa)
NEW 150 PVC
NOTE: ALL DIMENSIONS SHOWN ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
FINISHED
GRADE
100 (1 EA) PUMPER
CONNECTION FACING ROADWAY
63 (2 EA) FIRE HOSE
OUTLETS
NEW FIRE HYDRANT
(DRY BARREL TYPE WITH
150 MECH JOINT INLET)
MAX OF 600 ABOVE
LOAD BEARING SURFACE
Ø VARIESx45° PVC
PLUG
NOTES:
1. ASSUME VEHICLE TRAFFIC ARE ON ALL SIDES OF THE HYDRANT.
2. ONLY ADD BOLLARDS ON THE SIDE OF HYDRANT EXPOSED TO VEHICLE
TRAFFIC. A MINIMUM OF 2 BOLLARDS SHALL BE INSTALLED.
HYDRANT
BOLLARD
RE: F6/CU502
MAINTAIN
1000 SEPARATION
FINISH GRADE1
GAS METER
UNION
PLUGGING TEE WITH BUSHING AND 10mm PLUG
GAS PRESSURE REGULATOR
INSULATING UNION
PLUGGING TEE WITH
BUSHING AND 10mm PLUG
PROVIDE EARTHQUAKE AUTOMATIC
GAS SHUTOFF VALVE PER
SPECIFICATION SECTION 33 51 13.00 30
EXISTING ISOLATION VALVE
TO BUILDING
F1
GROUND CLEANOUT DETAIL
NTS
D1
BOLLARD PLACEMENT AT HYDRANT DETAIL
NTS
D5
GAS METER AND REGULATOR DETAIL
NTS
F6
BOLLARD DETAIL
NTS
C8
POST INDICATOR VALVE DETAIL
NTS
A8
TYPICAL VALVE SETTING
NTS
A1
LAND SIDE FIRE HYDRANT W/GATE VALVE DETAIL
NTS
PE PIPE OR COATED STEEL
PIPE PER SPECIFICATION
SECTION 33 51 15
CONNECT TO EXISTING ISOLATION VALVE
M
O V
T
E
V
A L V
E
F
R O
M
F
I R
E
H
Y D
R A
S
E M
B L Y
M A
R K
O
SEAL
JAMES D. EMERSON
62773
05-21-2020
SEAL
05-21-202009-25-2020
10/02/2020
STANDARD HOOK SCHEDULE
BAR
SIZE
FINISHED BEND
DIAMETER "D"
D13 80
D16 95
D19 115
D22 135
90 DEG.
HOOKS
"L"
D10 60 155
D25 155 410
"L
"D" f'c = 24 MPa f'c = 27 MPa
HOOK DEVELOPMENT
140 130
190 180
240 220
330 310
380 360
440 410
"Ldh"
CRITICAL
SECTION
LENGTH "Ldh"
NOTE:
1. INCREASE DEVELOPMENT & LAP LENGTH FOR TOP BARS BY 30%.
TOP BARS ARE HORIZONTAL REINFORCING
WITH MORE THAN 300 CONCRETE CAST BELOW.
2. DEVELOPMENT & LAP LENGTHS SHOWN ASSUME CLEAR SPACING OF BARS IS
NOT LESS THAN TWO TIMES THE BAR DIAMETER AND CLEAR COVER
IS NOT LESS THAN THE BAR DIAMETER. IF CLEAR SPACING OR COVER
IS LESS THAN LIMITS INDICATED, INCREASE DEVELOPMENT & LAP LENGTHS BY 50%.
3. FOR DOWEL BARS EXTENDING FROM AN INITIAL CONC. POUR INTO A SUBSEQUENT POUR,
PROVIDE AT LEAST DEVELOPMENT LENGTH EMBEDMENT INTO INITIAL POUR. IF DEVELOPMENT
LENGTH IN INITIAL POUR IS NOT AVAILABLE, PROVIDE STANDARD 90 DEGREE HOOK
W/ HOOK DEVELOPMENT LENGTH SHOWN BELOW.
DEVELOPMENT & LAP SPLICE TABLE
BAR SIZE
f'c = 24 MPa f'c = 27 MPa
SPLICE LENGTH
D10 360 340
D13 480 460
D16 600 570
D19 850 800
D22 1230 1160
D25 1400 1320
D29 1790 1680
D32 1990 1870
D35 2180 2060 f'c = 24 MPa f'c = 27 MPa
DEVELOPMENT LENGTH
280 270
370 350
470 440
650 620
950 890
1080 1020
1380 1300
1530 1440
1680 1580
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V
- 1
-D
-0
-0
S im u la to r_
S T
R .r v t
A F
-1
-2
-0
M A
R C
H
As indicated
10/2/2020 1:10:52
AM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_STR.rvt
T V
E R
S T
J S
H A
R P
S H
A
IR
R K
N O
L L E
S-002
P
G
IE
S S
E L
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
S S
-0
NTS
STANDARD HOOK SCHEDULE
C8
NTS
TYPICAL LAP SPLICE DETAIL
E8
GENERAL NOTES CONTINUED
CONCRETE
3.1 REINFORCING
A. STEEL BARS FOR CONCRETE REINFORCEMENT SHALL CONFORM WITH JIS G3112 AND THE FOLLOWING.
1. REINFORCING STEEL D16 AND SMALLER SHALL BE SD295 DEFORMED BARS, WITH MINIMUM YIELD
STRENGTH OF 295 MPA UNLESS NOTED OTHERWISE.
2. REINFORCING STEEL D19 AND LARGER SHALL BE SD345 DEFORMED BARS, WITH A MINIMUM YIELD
STRENGTH OF 345 MPA UNLESS NOTED OTHERWISE.
3. WELDED WIRE FABRIC SHALL CONFORM WITH JIS G3551 AND SHALL BE CONTACT LAP SPLICED
TWO FULL WIRE SPACES.
4. ADDITIONAL REQUIREMENTS FOR BARS THAT ARE TO BE PART OF THE SPECIAL REINFORCED
CONCRETE SHEAR WALLS:
A. YIELD STRENGTH SHALL NOT EXCEED 469 MPA.
B. YIELD RATIO PER JIS G3112 ANNEX JA.1 SHALL BE MET.
5. REINFORCING, INCLUDING DOWELS, SHALL BE SECURELY TIED AND CAST WITH THE LOWER
MEMBER. PLACING REINFORCING AFTER CONCRETE HAS BEEN PLACED IS NOT PERMITTED.
6. FIELD BENDING OF REINFORCING PARTIALLY EMBEDDED IN CONCRETE IS NOT ALLOWED UNLESS
SPECIFICALLY NOTED IN THE STRUCTURAL DOCUMENTS OR APPROVED BY GOVERNMENT.
7. PROVIDE DOWELS FROM FOUNDATION THE SAME GRADE, SIZE, AND NUMBER AS VERTICAL WALL
OR COLUMN REINFORCING, UNLESS NOTED OTHERWISE.
8. PROVIDE CORNER BARS TO MATCH HORIZONTAL REINFORCING AT CORNERS AND INTERSECTIONS.
9. MECHANICAL COUPLERS SHALL BE UNI-AXIAL TYPE OR EQUIVALENT CAPABLE OF DEVELOPING
125% OF THE SPECIFIED TENSILE STRENGTH OF THE SPLICED BAR. FOR D19 AND LARGER BARS GAS PRESSURE WELDED SPLICES ARE ACCEPTABLE IN LIEU OF MECHANICAL COUPLERS OR LAP SPLICES.
3.2 CAST-IN-PLACE CONCRETE
A. REINFORCED CONCRETE SHALL HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE STRENGTHS:
1. CLASS A 24 MPA NORMAL WEIGHT CONCRETE
2. CLASS B 27 MPA NORMAL WEIGHT CONCRETE
3. CLASS C 18 MPA NORMAL WEIGHT CONCRETE
B. PLACE CONCRETE AS FOLLOWS:
1. CLASS A:
A. SLAB-ON-GRADE
2. CLASS B:
A. FOUNDATIONS
B. COLUMNS, WALLS
C. GIRDERS, BEAMS, STRUCTURAL SLABS
3. CLASS C:
A. MUD SLAB BELOW FOUNDATIONS
C. PROVIDE CONCRETE COVER FOR REINFORCING AS FOLLOWS UNLESS NOTED OTHERWISE:
1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH................75 MM
2. CONCRETE EXPOSED TO EARTH OR WEATHER (D19 OR GREATER)...................50 MM
3. CONCRETE EXPOSED TO EARTH OR WEATHER (D16 AND SMALLER)..................40 MM
4. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
A. SLABS AND WALLS...................................................................................................20 MM B. BEAMS AND COLUMNS............................................................................................40 MM
D. PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB-ON-GRADE AS INDICATED IN THE
STRUCTURAL DRAWINGS.
E. CONSTRUCTION JOINTS IN WALLS SHALL BE KEYED AND PLACED AT LOCATIONS APPROVED BY
CONTRACTING OFFICER'S REPRESENTATIVE.
F. LOCATE CONSTRUCTION JOINTS FOR JOISTS, BEAMS, GIRDERS, AND SUSPENDED SLABS IN
THE MIDDLE 1/3 OF THE SPAN. PLACE JOINTS SO THEY DO NOT COMPROMISE THE STRENGTH
OF THE STRUCTURE. OFFSET JOINTS IN A GIRDER AT LEAST TWICE THE BEAM WIDTH
FROM A BEAM/GIRDER INTERSECTION.
G. INTERFACE OF CONSTRUCTION JOINTS SHALL BE ROUGHENED TO A FULL AMPLITUDE OF 6
MILLIMETERS. SURFACE OF CONSTRUCTION JOINTS SHALL BE CLEAN AND FREE OF LAITANCE.
IMMEDIATELY BEFORE NEW CONCRETE IS PLACED, CONSTRUCTION JOINTS SHALL BE WETTED AND
STANDING WATER REMOVED.
H. REFER TO SPECIFICATIONS SECTION 03 15 00.00 10 FOR WATERSTOPS.
I. PROVIDE COMPRESSIBLE FILLER AND SEALANT IN SLAB-ON-GRADE AND WALL AND COLUMN
INTERFACES THAT ARE NOT DOWELED TOGETHER.
J. ALL COLUMN POCKETS SHALL BE FILLED WITH CONCRETE AFTER COLUMN IS ERECTED.
K. CONDUIT AND PIPES EMBEDDED IN WALLS, BEAMS, OR SLABS SHALL BE NO LARGER IN OUTSIDE
DIMENSION THAN 1/3 THE OVERALL MEMBER THICKNESS OR 50 MILLIMETERS MAXIMUM, AND SHALL
BE PLACED NO CLOSER THAN 3 DIAMETERS OR WIDTHS ON CENTER.
L. CONDUIT AND PIPES, WITH THEIR FITTINGS, EMBEDDED WITHIN A COLUMN SHALL NOT DISPLACE
MORE THAN 4 PERCENT OF THE AREA OF THE COLUMN CROSS SECTION.
M. PROVIDE 100 MM HIGH CONCRETE HOUSEKEEPING PADS UNDER EQUIPMENT. PADS SHALL
EXTEND BEYOND EQUIPMENT 150 MM NOMINAL ON ALL SIDES. APPLY BONDING AGENT TO
EXISTING CONCRETE SLAB PRIOR TO PLACING HOUSEKEEPING PAD. SEE DOCUMENTS FROM
OTHER DISCIPLINES FOR EQUIPMENT SIZE AND LOCATIONS.
N. AT FLOOR DRAINS, LOCALLY SLOPE FLOOR TOWARDS DRAIN. SEE DOCUMENTS FROM OTHER
DISCIPLINES FOR DRAIN LOCATIONS.
O. PROVIDE 20 MM CHAMFER AT THE CORNERS OF COLUMNS AND WALLS WITH ANGLES OF 90
DEGREES OR LESS.
P. SEE ARCHITECTURAL DOCUMENTS FOR MOLDS, GROOVES, REVEALS, ORNAMENTS, CLIPS, ETC.
REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF FLOOR FINISHES AND SLAB
DEPRESSIONS.
METALS
4.1 STRUCTURAL STEEL
A. GENERAL
1. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC 360-10
“SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”.
2. MATERIALS SHALL CONFORM TO JIS G3101 AND THE FOLLOWING, UNLESS NOTED OTHERWISE.
A. H SHAPES JIS G3136 SN490B, 325 MPA YIELD STRENGTH
B. CHANNELS AND ANGLES JIS G3101 SS400, 235 MPA YIELD STRENGTH
C. PLATES JIS G3101 SS400, 235 MPA YIELD STRENGTH
D. SQUARE AND RECTANGULAR TUBES JIS G3466 STKR400, 245 MPA YIELD STRENGTH
E. ROUND TUBES JIS G3444 STK400, 235 MPA YIELD STRENGTH
F. BOLTS JIS B1180
G. HIGH STRENGTH BOLTS JIS B1186, F10T
H. ANCHOR RODS JIS B1220 SNR 490B, 325 MPA YIELD STRENGTH
I. ELECTRODES MATCHING STRENGTH, 484 MPA MIN.
3. BEAM CONNECTIONS SHALL BE AS INDICATED ON THE STRUCTURAL DRAWINGS.
4. ALL BOLTED CONNECTIONS SHALL BE DESIGNED AS FULLY TENSIONED BEARING CONNECTIONS WITH
THREADS INCLUDED IN THE SHEAR PLANE, UNLESS NOTED OTHERWISE.
4.2 METAL DECK
A. GENERAL
1. METAL DECK SHALL CONFORM TO JIS G3352, SGH400. GALVANIZED SHEET STEEL SHALL CONFORM TO
JIS G3302.
2. DECK SHALL BE CONTINUOUS OVER 3 SPANS, UNLESS NOTED OTHERWISE.
3. AT SUPPORTS PARALLEL TO THE DECK SPAN, RAISE STEEL SUPPORTS OR PROVIDE SHIMS AT
FASTENING POINTS IF THE DECK VALLEY DOES NOT ENGAGE THE SUPPORT.
B. SIMULATOR ROOF DECK
1. ROOF DECK SHALL BE GALVANIZED.
2. NIPPON STEEL AND SUMIKIN METAL PRODUCTS UA-R, 75 MM DEEP BY 1.2 MM THICK METAL DECK, OR
APPROVED EQUIVALENT.
3. DECK SHALL BE FASTENED TO SUPPORTS, BOTH PERPENDICULAR
AND PARALLEL TO THE DECK, WITH HILTI X-ENP-19 L15 POWDER ACTUATED FASTENERS OR APPROVED
EQUIVALENT AND FASTENED AT SIDELAPS WITH NO. 10 SCREWS AS FOLLOWS:
A. TYPICAL INSTALLATION, UNLESS NOTED OTHERWISE:
1) POWDER ACTUATED FASTENER PATTERN: 1 FASTENER PER VALLEY (200 MM O.C.)
AND AT 300 MM MAX. FOR PARALLEL SUPPORTS
2) SIDELAP FASTENERS: 2/SPAN, MAXIMUM SPACING OF 600 MM
4.3 POST-INSTALLED ANCHORS AND DEFORMED BAR DOWELS TO CONCRETE.
A. ANCHORS SHALL BE EXPANSION OR ADHESIVE ANCHORS, AS NOTED IN CONSTRUCTION DRAWINGS, UNLESS NOTED OTHERWISE.
B. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN
INSTRUCTIONS.
C. WHEN INSTALLING ANCHORS, DO NOT CUT EXISTING REINFORCING. LOCATE EXISTING REINFORCING BARS WITH PACHOMETER OR SIMILAR MEANS, MARKING LOCATION AND DIRECTION OF EACH BAR IN THE VICINITY
OF EACH PROPOSED HOLE LOCATION.
D. INSTALL ANCHORS TO ACCOMMODATE THE STANDARD HOLE SIZE IN STEEL.
E. THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE
INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING
ANCHORS.
F. CONCRETE BASE MATERIAL ANCHORS BASIS OF DESIGN:
1. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN
TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193.
A. FOR EXAMPLE, PRE-APPROVED MECHANICAL ANCHORS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING:
1) HILTI KWIK-BOLT TZ (ICC-ES ESR-1917) OR EQUIVALENT
B. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN
INSTRUCTIONS.
2. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED
AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308.
A. FOR EXAMPLE, PRE-APPROVED ADHESIVE ANCHORS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING:
1) HILTI HIT-HY 200 (ICC-ES ESR-3187) OR EQUIVALENT
2) HILTI HIT-RE-500-V3 (ICC-ES ESR 3814) OR EQUIVALENT
B. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN
INSTRUCTIONS.
C. STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD (OR EQUIVALENT)
OR CONTINUOUSLY DEFORMED STEEL REBAR.
D. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS.
G. FOR POST INSTALLED ANCHORS, SUBMIT THE FOLLOWING:
1. DOCUMENTATION SHOWING THAT THE PROPOSED ANCHOR HAS BEEN TESTED AND APPROVED FOR
USE IN CRACKED CONCRETE.
2. CALCULATIONS PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER.
H. ANCHOR INSTALLATIONS SHALL BE TESTED AND INSPECTED BY THE CONTRACTOR’S TESTING AND
INSPECTION AGENCY. SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE
REQUIREMENTS SET OUT BELOW AND PER CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE:
1. WRITTEN SPECIAL INSPECTION REPORTS SHALL BE SUBMITTED TO THE GOVERNMENT INDICATING THE
NUMBER AND LOCATION OF TESTS, TEST TYPE CONDUCTED, TEST RESULTS, AND FINAL DISPOSITION OF ANCHOR INSTALLATION AND CONFIRMATION OF THE INFORMATION OUTLINED WITHIN THE “SPECIAL
INSPECTION AND TESTING REQUIREMENTS” BELOW.
2. ANY ANCHOR FAILING THE SPECIFIED CRITERIA SHALL BE MARKED WITH RED SPRAY PAINT AND NOT USED TO SATISFY CONTRACT REQUIREMENTS. ALL FAILED ANCHORS SHALL BE BROUGHT TO THE
ATTENTION OF THE CONTRACTING OFFICER FOR REINSTALLATION OR ALTERNATE ANCHORAGE
INSTALLATION BY THE CONTRACTOR.
3. SPECIAL INSPECTION AND TESTING REQUIREMENTS:
A. ADHESIVE ANCHOR TESTING SHALL BE PERFORMED PERIODICALLY BY A SPECIAL INSPECTOR PER
THE FOLLOWING CRITERIA:
1) THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE INITIALLY DURING ANCHOR INSTALLATION TO
VERIFY ANCHOR PRODUCT NAME, ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE/MASONRY
TYPE, CONCRETE/MASONRY COMPRESSIVE STRENGTH, ADHESIVE IDENTIFICATION AND
EXPIRATION DATE, HOLE DIMENSIONS, HOLE CLEANING PROCEDURES, ANCHOR SPACING, EDGE
DISTANCES, CONCRETE/MASONRY THICKNESS, ANCHOR EMBEDMENT, TIGHTENING TORQUE,
AND ADHERENCE TO THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS AND SHALL
SUBMIT REPORT WHICH INCLUDES THE ABOVE INFORMATION.
2) THE SPECIAL INSPECTOR MUST VERIFY THE INITIAL INSTALLATIONS OF EACH TYPE AND SIZE OF
ADHESIVE ANCHOR BY CONSTRUCTION PERSONNEL ON SITE.
3) SUBSEQUENT INSTALLATIONS OF THE SAME ANCHOR TYPE AND SIZE BY THE SAME
CONSTRUCTION PERSONNEL ARE PERMITTED TO BE PERFORMED IN THE ABSENCE OF THE
SPECIAL INSPECTOR. ANY CHANGE IN THE ANCHOR PRODUCT BEING INSTALLED OR THE
PERSONNEL PERFORMING THE INSTALLATION REQUIRES AN INITIAL INSPECTION. FOR ONGOING
INSTALLATIONS OVER AN EXTENDED PERIOD, THE SPECIAL INSPECTOR MUST MAKE REGULAR
INSPECTIONS TO CONFIRM CORRECT HANDLING AND INSTALLATION OF THE PRODUCT.
B. MECHANICAL ANCHOR TESTING SHALL BE PERFORMED PERIODICALLY WITH THE SPECIAL
INSPECTOR SUBMITTING A REPORT THAT INCLUDES THE FOLLOWING DETAILS:
1) ANCHOR DESCRIPTION, INCLUDING THE ANCHOR PRODUCT NAME, ANCHOR TYPE, NOMINAL
ANCHOR AND BOLT DIAMETERS, AND ANCHOR LENGTH.
2) HOLE DESCRIPTION, INCLUDING HOLE DIMENSIONS, ANCHOR EMBEDMENT, AND VERIFICATION OF
DRILL BIT COMPLIANCE WITH ANSI B212.15-1994.
3) INSTALLATION DESCRIPTION, INCLUDING VERIFICATION OF CONCRETE/MASONRY TYPE,
CONCRETE/MASONRY COMPRESSIVE STRENGTH, MEMBER THICKNESS, VERIFICATION OF
ANCHOR INSTALLATION AND LOCATION (SPACING AND EDGE DISTANCE), TIGHTENING TORQUE,
AND ADHERENCE TO THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS AND ESR
REPORT.
END OF STRUCTURAL GENERAL NOTES
M A
S
C R
IP
T
IO
N
D A
T E
R
E V
IS
E
D C
A S
T -I
N -P
L A
C E
C O
N C
R E
T E
N O
T E
H
O C
T
BEAM
FACE OF CONCRETE
USE SHEAR PL. w/
SEE STEEL GIRDER
SCHEDULE
END CONNECTION
HEADED STUDS
TYP.
SEE
SCHEDULE
EMBED PLATE
PER PLAN & SCHED.
EP02
25 MAX. CLR.
HAIRPIN
SUPPLEMENTAL
REINF.
EP01
50 200 50
D10 HAIRPIN
SUPPLEMENTAL
REINF.
(TYP.)
T
Y P
T
Y P
50 200 50
STEEL GIRDER, SEE PLAN
& SCHEDULE
NOTE: SHOP WELD AT CONTRACTOR'S OPTION
D16 @ EA. ROW OF
STUDS, EXTEND BARS 610
BEYOND LAST STUD
EP03
35 230 35
EP04
50 100 100 50
EP05
35 230 35
OPTIONAL ERECTION ANGLE BY CONTRACTOR
EMBED. PLATE SCHEDULE
EMBED. PLATE SIZE
T x H x W
16x300x300
EMBED PLATE
DESIGNATION
EP01
EP02
HEADED
STUDS
(4) 19Øx150 LG.
16x300x500 (4) 19Øx150 LG.
EP03 16x225x300 (4) 19Øx150 LG.
NOTES
NO HAIRPINS REQ'D
EP04 16x225x300 (6) 19Øx200 LG.
EP05 16x200x300 (4) 19Øx100 LG. NO HAIRPINS REQ'D
NO HAIRPINS REQ'D
EP06 16x400x250 (4) 19Øx150 LG.
EP07
50 200 50
EP07 16x700x300 (8) 19Øx150 LG.
EP08 16x500x300 (6) 19Øx150 LG.
EP09 16x200x200 (4) 19Øx100 LG.
EP08
50 200 50
EP09
35 130 35
NO HAIRPINS REQ'D
ADDITIONAL
COLUMN STIRRUP.
MATCH SIZE PER
COLUMN SCHEDULE
(3) D19 HAIRPIN
SUPPLEMENTAL
REINF.
EP06
50 150 50
ADDITIONAL
BEAM STIRRUP.
MATCH SIZE PER
BEAM SCHEDULE
EQ EQ
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V
- 1
-D
-0
-0
S im u la to r_
S T
R .r v t
A F
-1
-2
-0
M A
R C
H
1 : 1010/2/2020 1:07:03
AM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_STR.rvt
T V
E R
S T
J S
H A
R P
S H
A
IR
R K
N O
L L E
S-608
P
G
IE
S S
E L
E M
B E
D P
L A
T E
S C
H E
D U
L E
S -6
- NTS
TYPICAL EMBED PLATE SCHEDULE & DETAILS
A4
M A
S
C R
IP
T
IO
N
D A
T E
C
H A
N G
E D
E M
B E
D P
L A
T E
S C
H E
D U
L E
H E
A D
E D
S T
U D
S T
O
D
IA
O
C T
12F
FIRE RATING
W: STUD SIZE HEIGHT
C OR F
FIRE RATED STUD WALLS
U21
THICKNESS
DESIGNATION
1 THRU 8
RATING
1-HR OR 2-HR
FIRE RATED CONCRETE WALLS
CONCRETE
A1C
TYPE
W: STUD SIZE
HEIGHT
C = 100mm ABOVE CEILING
F = FULL HEIGHT TO STRUCTURE ABOVE
LINE OF STRUCTURE
METAL RUNNER
METAL STUDS AT MAXIMUM 600 mm
OC
GYPSUM BRD:
12.7mm (1/2") FIRE RATED TYPE
EACH SIDE
LINE OF STRUCTURE
DEFLECTION TRACK
SEALANT - EACH SIDE
SCHEDULED CEILING
HEAD
CEILING
PLAN
SEALANT - EACH SIDE
SOUND ATTENUATION:
ROCK WOOL (NRC 1.00 MIN)
BLANKET INSULATION;
THICKNESS TO MATCH
STUD SIZE.
REFER TO
PARTITION
HEAD DETAILS
BASE
11F W= 65mm 12F W= 90mm
1 HR FIRE RATED ASSEMBLY: UL DESIGNS U419
REFER SHEET A-005 FOR UL ASSEMBLY INFORMATION.
LINE OF STRUCTURE
METAL RUNNER
METAL STUDS AT 303 mm O.C.
12.5 mm GYPSUM BD
EACH SIDE
SEALANT - EACH SIDE
SCHEDULED CEILING
CEILING
PLAN
BASE
A2C W= 90mm
A1C W= 65mm
METAL RUNNER
METAL STUD
DIAGONAL BRACING
TO STRUCTURE ABOVE
AT 1200mm O.C. MAX
SOUND ATTENUATION:
ROCK WOOL (NRC 1.00
MIN)
BLANKET INSULATION;
THICKNESS TO MATCH
STUD SIZE
STC 40
LINE OF STRUCTURE
METAL RUNNER
METAL STUDS AT 303mm O.C.
12.5 mm GYPSUM BD
EA SIDE
LINE OF STRUCTURE
DEFLECTION TRACK
SEALANT - EACH SIDE
SCHEDULED CEILING
HEAD
CEILING
PLAN
BASE
E2F W= 90mm
*MIN. STC=45
SOUND ATTENUATION:
ROCK WOOL (NRC 1.00 MIN)
BLANKET INSULATION;
THICKNESS TO MATCH STUD
SIZE
SEE PLAN
SEALANT - EACH SIDE
REFER TO
PARTITION
HEAD DETAILS
LINE OF STRUCTURE
METAL RUNNER
METAL STUDS AT 303mm O.C.
12.5 mm GYPSUM BD
SEALANT
SCHEDULED CEILING
CEILING
PLAN
BASE
F2C W= 90mm
F1C W= 65mm
METAL RUNNER
SOUND INSULATION: ROCK
WOOL (NRC 1.00 MIN)
BLANKET INSULATION;
THICKNESS TO MATCH STUD
SIZE
F2F W= 90mm
F1F W= 65mm
EXTEND TO STRUCTURE
AT F1F AND F2F
LINE OF STRUCTURE
METAL RUNNER
METAL STUDS AT 303mm O.C.
12.5 mm GYPSUM BD
LINE OF STRUCTURE
DEFLECTION TRACK
SEALANT
SCHEDULED CEILING
HEAD
CEILING
PLAN
BASE
G2F W= 90mm
G1F W= 65mm
EXTEND TO STRUCTURE
AT G1F AND G2F
G2C W= 90mm
G1C W= 65mm
REFER TO
PARTITION
HEAD DETAILS
EXTERIOR CONCRETE WALL
REFER STRUCTURE PLANS
60MM RIGID BOARD
INSULATION MIN R-2.76
METAL STUDS AT 303mm O.C.
12.5 mm GYPSUM BD
LINE OF STRUCTURE
DEFLECTION TRACK
SEALANT - EACH SIDE
SCHEDULED CEILING
HEAD
CEILING
PLAN
BASE
H1F W= 65mm
.15 MM THK VAPOR
RETARDER UNDER
GYPSUM BD
64 MM THK ROCK WOOL
THERMAL INSULATION
R=1.429 PER 50mm
THICKNESS
REFER TO
PARTITION
HEAD DETAILS
LINE OF STRUCTURE
NOTE: WHERE THE HEIGHT OF METAL STUDS EXCEEDS 3 600,
PROVIDE METAL CLIPS ON EACH STUD IN SAME GAUGE AS METAL
STUDS SPACED AT 1 500 OC FOR FULL HEIGHT OF STUD WALL.
45.00°
CEILING AS SCHEDULED
INTERIOR WALL TYPE -
REFER TO FLOOR PLAN.
CEILING AS
SCHEDULED
DECK ABOVE
90MM METAL STUD STRUTS
(0.8MM THICKNESS) @ 606MM
O.C. MAX. SEE FLOOR PLAN -
NOTATIONS FOR LOCATIONS
METAL STUD CHANNEL
RUNNER SECURED TO DECK
ABOVE OR WALL STUDS. USE
WIDTH REQUIRED TO SPAN
FLUTES. BEND FLANGES TO
ENGAGE BRACING STRUTS.
STEADY BRACE @ 1200MM
MAX WHERE STRUTS
GREATER THAN 1200MM LONG.
SEE TYPICAL HEAD
OF WALL &
DEFLECTION TRACK
DETAILS
NOTE:
PROVIDE BRACING ONE
SIDE OF WALL @ ALL
INTERIOR WALLS GREATING
THAN 5500MM TALL
NOTE:
LOCATE BRACING ON SIDE
OF WALL OPPOSITE OF
SPACE W/HIGH CEILING
OR CLERE-STORIES.
BOTTOM OF BRACING - STRUCTS
5500 A.F.F.METAL STUD CHANNEL
RUNNER SECURED TO DECK
ABOVE OR WALL STUDS. USE
WIDTH REQUIRED TO SPAN
FLUTES. BEND FLANGES TO
ENGAGE BRACING STRUTS.
GENERAL NOTES:
SHEET ID
D R
A W
N B
Y
D E
S I G
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L I C
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V -1
-D
- 0
-0
S im u l a to r_
A rc h . r v t
A F
-1
-2
-0
M
A R
C H
As indicated
10/5/2020 11:10:02
AM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
S A
B S
H
IR
E
S A
B S
H
IR
E
R K
N O
L L E
A-003
A H
A U
C K
-K A
L T
I
IN
T
E R
IO
R
W A
L L T
Y P
E S
A -0
Interior Wall Type G
Interior Wall Type H1F
Interior Wall Type 1_F
Interior Wall Type A_CInterior Wall Type E_F
Interior Wall Type F_C, F_F
INTERIOR WALL TYPES:
TYPE 1 - 1-HR RATED WITH STUDS
TYPE 2 - NOT USED.
TYPE A - TYPICAL WITH INSULATION
TYPE B - NOT USED.
TYPE C - NOT USED.
TYPE D - NOT USED.
TYPE E - CHASE
TYPE F - FURRING - WITH INSULATION
TYPE G - FURRING - NO INSULATION
TYPE H - FURRING - AT EXTERIOR CONCRETE WALL
TYPE J - STC 45
TYPE K - NOT USED.
TYPE L - BLAST RESISTANT
TYPE P - SECURE; STC 50
TYPE R - UNBALANCED, WITH INSULATION, STC 50
TYPE S - SMOKE RATED WITH INSULATION
TYPE T - NOT USED.
TYPE U - FIRE RATED CONCRETE
TYPE V - NON- RATED CONCRETE
WALL REFERENCING SYMBOL NOTES:
1. INTERIOR WALL TYPES LIST INDICATES ALL
INTERIOR WALL TYPES AVAILABLE IN
PROJECT.
2. SEE WALL REFERENCING SYMBOL NOTES
FOR EXPLANATION OF WALL TYPE AND
STUD INFORMATION. WALL INFORMATION
IS INDICATED ON FLOOR PLAN NOTATIONS
SHEET AS INTERIOR PARTITION
REFERENCING SYMBOL.
3. REFER SHEET A-002 FOR ALL OTHER
GENERAL NOTES PERTAINING TO
INTERIOR PARTITIONS.
4. FOR ALL CONCRETE WALLS (INTERIOR
AND EXTERIOR) REFER TO STRUCTURE
DRAWINGS, CONCRETE WALL
ELEVATIONS, FOR ALL INFORMATION.
5. WHERE METAL CLIPS ARE REQUIRED FOR
SUPPORT OF METAL STUDS AT HIGH BAY,
PROVIDE CLIP MEETING ASTM A653/A653M
OR JIS EQUIVALENT. "L" TYPE SUPPORT
CLIP, MINIMUM LENGTH 75MM, WITH
SHORT LEG MINIMUM 50MM AND LONG
LEG (FOR FULL CONTACT WITH FACE OF
STUD) 125MM. CLIP GAUGE SAME AS STUD
GAUGE. FASTEN TO CONCRETE WALL
WITH (2) POWDER ACTUATED FASTENERS,
SHANK DIAMETER 0.145", HEAD DIAMETER
0.3", AND EMBED MINIMUM 20MM. SPACE
FASTENERS ON CLIP 50 MM. VERIFY SIZES
WITH JAPANESE MANUFACTURED
MATERIALS.
1 : 12
TYP. TALL INTERIOR WALL BRACING
D7
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
B id I n q u ir y
-0
-2
B id
I n q u ir y
-0
-2
3. REFER SHEET A-002 FOR ALL OTHER
GENERAL NOTES PERTAINING TO
INTERIOR PARTITIONS.
4. FOR ALL CONCRETE WALLS (INTERIOR
AND EXTERIOR) REFER TO STRUCTURE
DRAWINGS, CONCRETE WALL
ELEVATIONS, FOR ALL INFORMATION.
5. WHERE METAL CLIPS ARE REQUIRED FOR
SUPPORT OF METAL STUDS AT HIGH BAY,
PROVIDE CLIP MEETING ASTM A653/A653M
OR JIS EQUIVALENT. "L" TYPE SUPPORT
CLIP, MINIMUM LENGTH 75MM, WITH
SHORT LEG MINIMUM 50MM AND LONG
LEG (FOR FULL CONTACT WITH FACE OF
STUD) 125MM. CLIP GAUGE SAME AS STUD
GAUGE. FASTEN TO CONCRETE WALL
WITH (2) POWDER ACTUATED FASTENERS,
SHANK DIAMETER 0.145", HEAD DIAMETER
0.3", AND EMBED MINIMUM 20MM. SPACE
FASTENERS ON CLIP 50 MM. VERIFY SIZES
WITH JAPANESE MANUFACTURED
MATERIALS.
NOTE: WHERE THE HEIGHT OF METAL STUDS EXCEEDS 3 600,
PROVIDE METAL CLIPS ON EACH STUD IN SAME GAUGE AS METAL
STUDS SPACED AT 1 500 OC FOR FULL HEIGHT OF STUD WALL.
FIRST FLOOR
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
FACTORY FINISHED
BLAST-RESISTANT
STOREFRONT SYSTEM
WITH INSULATED
LAMINATED GLAZING.
12.5 MM GYPSUM
BOARD.
FACTORY FINISHED
METAL GUTTER.
CEILING AS
SCHEDULED.
9.5
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
64 MM ROCK WOOL
INSULATION.
CORRIDOR
CO1
C1
A-525
50 MM STEEL METAL
DECK
HOLD INSULATION
TIGHT TO DECK, SEAL
ALL FLUTES WITH
FOAM INSULATION
CONCRETE
FLOOR SLAB,
FOUNDATION
WALL AND
FOOTING; REFER
STRUCTURE
FOUNDATION
PLAN
CONCRETE SIDEWALK,
REFER CIVIL SITE
DRAWINGS
DOWNSPOUT WITH
BOOT, CONNECT
TO BELOW GRADE
STORM SYSTEM
STRUCTURAL STEEL
SUPPORT FOR CATCH
WALL. REFER
STRUCTURAL DRAWINGS
FRAME INSULATION AND
VAPOR BARRIER TIGHT ALL
AROUND STEEL SUPPORT
DASHED LINE
INDICATES LINE OF
AIR BARRIER;
REFER A-131 AND
A-132 FOR
COMPONENTS AND
NOTES.
METAL GUTTER
WITH DOWNSPOUT
TO LOWER ROOF
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD
ON RIGID
POLYISOCYANURATE
INSULATION (1 LAYER
EACH 75MM AND 50MM
THICKNESSES) ON
VAPOR BARRIER
ENTRY CANOPY WITH
MODIFIED BITUMEN
ROOFING MEMBRANE,
REFER SHEET A-525
FLEXIBLE JOINT
FILLER AT
CONCRETE
SIDEWALK, REFER
CIVIL SITE
DRAWINGS
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
CEILING AS
SCHEDULED.
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
CONCRETE REVEAL
PATTERN. REFER TO
ELEVATIONS.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
64 MM ROCK WOOL
INSULATION.
TRAINING/
CLASSROOM
105B
CERAMIC TILE WITH
MORTAR INSET INTO
WALL. REFER
TYPICAL TILE
DETAILS MISC
DETAILS SHEET
A-533.
50 MM STEEL
METAL DECK
HOLD INSULATION
TIGHT TO DECK,
SEAL ALL FLUTES
WITH FOAM
INSULATION
CONCRETE BEAM,
REFER TO
STRUCTURE
ROOF FRAMING PLAN
CONCRETE FOUNDATION,
REFER TO STRUCTURE
FOUNDATION PLAN
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
DASHED LINE
INDICATES LINE OF
AIR BARRIER; REFER
A-131 AND A-132 FOR
COMPONENTS AND
NOTES.
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD
ON RIGID
POLYISOCYANUTRATE
ROOF INSULATION (1
LAYER EACH 75MM
AND 50MM
THICKNESSES) ON
VAPOR BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
CLEAR ANODIZED
ALUMINUM SUN
SHADE SYSTEM
ATTACHED TO
VERTICAL MULLIONS.
REFER TO FLOOR
PLANS FOR
LOCATIONS.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
FACTORY FINISHED
BLAST-RESISTANT
STOREFRONT SYSTEM
WITH INSULATED
LAMINATED GLAZING.
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
50 MM STEEL METAL
DECK.
SOLID SURFACE
WINDOW SILL.
64 MM ROCK WOOL
INSULATION.
TRAINING /
CLASSROOM
105A
CERAMIC TILE WITH
MORTAR INSET INTO
WALL. REFER
TYPICAL TILE DETAILS
MISC DETAILS SHEET
A-533.
F5
A-521
HOLD INSULATION
TIGHT TO DECK,
SEAL AT ALL
FLUTES WITH
FOAM INSULATION
CONCRETE
BEAM, REFER
STRUCTURE
ROOF
FRAMING PLAN
SCHEDULED
CEILING
CONCRETE
FOUNDATION,
REFER STRUCTURE
FOUNDATION PLAN
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
Sim
A9
A-612
DASHED LINE
INDICATES LINE OF
AIR BARRIER; REFER
A-131 AND A-132 FOR
COMPONENTS AND
NOTES.
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD
ON RIGID ROOF
INSULATION (1 LAYER
EACH 75MM AND
50MM THICKNESSES
ON VAPOR BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
FACTORY FINISHED
BLAST-RESISTANT
STOREFRONT SYSTEM
WITH INSULATED
LAMINATED GLAZING.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
CEILING AS
SCHEDULED.
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
B.2CLEAR ANODIZED
ALUMINUM COPING.
SOLID SURFACE
WINDOW SILL.
64 MM ROCK WOOL
INSULATION.
GOVERNMENT
OFFICE
CONCRETE BEAM,
REFER TO
STRUCTURAL
ROOF FRAMING PLAN
METAL DECK
HOLD INSULATION
TIGHT
TO METAL DECK,
SEAL FLUTES WITH
FOAM INSULATION
CONCRETE
FOUNDATION.
REFER TO
STRUCTURE
FOUNDATION
DRAWINGS.
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
D1
A-523
DASHED LINE INDICATES
LINE OF AIR BARRIER;
REFER TO A-131 AND
A-132 FOR COMPONENTS
AND NOTES.
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD
ON RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75 MM
AND 50MM
THICKNESSES) ON
VAPOR BARRIER
ATTACHMENT OF STUDS,
INSULATION TO WALL AT
PERIMETER BEAM
CONDITIONS: REFER
A5/A-525 FOR TYPICAL
(SIMILAR) DETAIL.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
1. SEAL ALL PENETRATIONS OF THE AIR
BARRIER, AND VERIFY INTEGRITY PRIOR
TO COVERING WITH OTHER MATERIALS.
2. FIRST FLOOR ELEVATION OF "0"
CORRESPONDS TO THE DATUM
ELEVATION OF FFE=130.70 ON CIVIL
SITE DRAWINGS.
3. DIMENSIONS SHOWN FOR WINDOW,
LOUVER AND DOOR OPENINGS ARE
ROUGH OPENINGS. REFER TO DOOR,
WINDOW AND LOUVER SCHEDULE
SHEETS SERIES A-600.
4. REFER INTERIOR WALL TYPES A-002
GENERAL NOTES FOR ATTACHMENT OF
STUDS TO CONCRETE AT WALLS ABOVE
3 600 HEIGHT.
5. REFER SHEET A-533 FOR "MISC DETAILS"
AND INFORMATION.
GENERAL NOTES:
SHEET ID
D R
A W
N B
Y
D E
S I G
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L I C
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V -1
-D
- 0
-0
S im u l a to r_
A rc h . r v t
A F
-1
-2
-0
M
A R
C H
As indicated
9/29/2020 5:42:47
PM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
A H
A U
C K
-K A
L T
I
M .K
G
E N
IS
R K
N O
L L E
A-311
M L
O H
S E
W A
L L S
E C
T
IO
N S
A A
-3
1 : 20
WALL SECTION
A7
1 : 20
WALL SECTION
A5
1 : 20
WALL SECTION
A3
1 : 20
WALL SECTION
A1 0 400
SCALE: 1: 20
800200
M A
S
C R
IP
T
IO
N
D A
T E
B id I n q u ir y
-3
-2
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
12.5 MM GYPSUM
BOARD.
CEILING AS
SCHEDULED.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
FACTORY FINISHED
BLAST-RESISTANT
STOREFRONT SYSTEM
WITH INSULATED
LAMINATED GLAZING.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
FACTORY FINISHED
METAL FASCIA
PANELS WITH DRIP
EDGE. VERTICAL
JOINTS TO ALIGN WITH
METAL ROOF SEAMS.
C.2 C
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
64 MM ROCK WOOL
INSULATION.
CORRIDOR
CO1
A5
A-521
50 MM STEEL
METAL DECK
HOLD INSULATION
TIGHT TO DECK,
SEAL AT ALL
FLUTES WITH
FOAM INSULATION
CONCRETE BEAM,
REFER TO STRUCTURE
ROOF FRAMING PLAN
CONCRETE REVEAL
PATTERN, REFER TO
ELEVATIONS
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATIONS, REFER
TO STRUCTURE
FOUNDATION PLAN
FLEXIBLE JOINT FILLER AT
CONCRETE SIDEWALK,
REFER CIVIL SITE
DRAWINGS.
FRAME INSULATION
AND VAPOR BARRIER
TIGHT ALL AROUND
STRUCTURE
CATCH WALL
STRUCTURE, REFER
STRUCTURAL TYPICAL
DETAILS S-502
DASHED LINE INDICATES LINE
OF AIR BARRIER; REFER A-131
AND A-132 FOR COMPONENTS
AND NOTES.
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD
ON RIGID
POLYISOCYANURATE
ROOF INSULATION (I
LAYER EACH 75MM
AND 50MM
THICKNESSES) ON
VAPOR BARRIER
CONCRETE SIDEWALK,
REFER CIVIL SITE
DRAWINGS
ATTACHMENT OF STUDS,
INSULATION TO PERIMETER
BEAM; REFER A5/A-525 FOR
TYPICAL (SIMILAR) CONDITION.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
CERAMIC TILE WITH
MORTAR INSET INTO
WALL.REFER TYPICAL
TILE DETAILS MISC
DETAILS SHEET A-500
SERIES.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
CEILING AS
SCHEDULED.
CONCRETE REVEAL -
SEE ELEVATION
SHEETS.
R E
F E
R E
L E
V A
T
IO
N S
CLEAR ANODIZED
ALUMINUM COPING.
B
64 MM ROCK WOOL
INSULATION.
BRIEFING/
DEBRIEFING
112B
MODIFIED
BITUMEN
ROOFING
SYSTEM
CAST-IN-PLACE CONCRETE
ROOF SLAB, REFER
STRUCTURE ROOF
FRAMING PLAN
OUTBOARD ROOF
DRAINAGE TRENCH
CONCRETE BEAM,
REFER STRUCTURE
ROOF FRAMING PLAN
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATIONS, REFER
STRUCTURE
FOUNDATION PLAN
DASHED LINE
INDICATES AIR
BARRIER; REFER
A-131 AND A-132
FOR
COMPONENTS
AND NOTES.
CONCRETE GROUT
SLOPED UP TO TRENCH
HIGH POINT BETWEEN
ROOF DRAINS
300 TYP
Sim
A5
A-525
PROTECTION BOARD, RIGID
POLYISOCYANURATE ROOF
INSULATION (1 LAYER EACH
75MM AND 50MM
THICKNESSES( ON VAPOR
BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
CERAMIC TILE WITH
MORTAR INSET INTO
WALL.REFER TYPICAL
TILE DETAILS MISC
DETAILS SHEET A-500
SERIES.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
12.5 MM GYPSUM
BOARD.
CEILING AS
SCHEDULED.
CLEAR ANODIZED
ALUMINUM COPING.
B
64 MM ROCK WOOL
INSULATION.
CIVILIAN OFFICE
Sim
C9
A-612
Sim
A9
A-612
MODIFIED
BITUMEN
ROOFING
SYSTEM
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATIONS, REFER
STRUCTURE
FOUNDATION PLAN
WINDOW SILL
CONCRETE ROOF SLAB,
PERIMETER BEAM, REFER
STRUCTURE ROOF FRAMING
PLAN
A9
A-521
GROUT BED,
MINIMUM 50MM
THICK AT DRAIN,
SLOPE UP TO
TRENCH HIGH POINT
OVERFLOW
SCUPPER
ROOF DRAIN,
REFER ROOF PLAN
DASHED LINE
INDICATES LINE
OF AIR BARRIER;
REFER A-131
AND A-132 FOR
COMPONENTS
AND NOTES.
Sim
A5
A-525
PROTECTION BOARD, RIGID
POLYISOCYANURATE ROOF
INSULATION (1 LAYER EACH
75MM AND 50MM
THICKNESSES( ON VAPOR
BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
1. SEAL ALL PENETRATIONS OF THE AIR
BARRIER, AND VERIFY INTEGRITY PRIOR
TO COVERING WITH OTHER MATERIALS.
2. FIRST FLOOR ELEVATION OF "0"
CORRESPONDS TO THE DATUM
ELEVATION OF FFE=130.70 ON CIVIL
SITE DRAWINGS.
3. DIMENSIONS SHOWN FOR WINDOW,
LOUVER AND DOOR OPENINGS ARE
ROUGH OPENINGS. REFER TO DOOR,
WINDOW AND LOUVER SCHEDULE
SHEETS SERIES A-600.
4. REFER INTERIOR WALL TYPES A-002
GENERAL NOTES FOR ATTACHMENT OF
STUDS TO CONCRETE AT WALLS ABOVE
3 600 HEIGHT.
5. REFER SHEET A-533 FOR "MISC DETAILS"
AND INFORMATION.
GENERAL NOTES:
SHEET ID
D R
A W
N B
Y
D E
S I G
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L I C
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V -1
-D
- 0
-0
S im u l a to r_
A rc h . r v t
A F
-1
-2
-0
M
A R
C H
As indicated
9/29/2020 5:42:48
PM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
A H
A U
C K
-K A
L T
I
M .K
G
E N
IS
R K
N O
L L E
A-312
M L
O H
S E
W A
L L S
E C
T
IO
N S
A A
-3
1 : 20
WALL SECTION
A6
1 : 20
WALL SECTION
A1 1 : 20
WALL SECTION
A4 0 400
SCALE: 1: 20
800200
M A
S
C R
IP
T
IO
N
D A
T E
B id I n q u ir y
-3
-2
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
CONCRETE REVEAL -
SEE ELEVATION
SHEETS.
CLEAR ANODIZED
ALUMINUM COPING.
50 MM STEEL METAL
DECK.
CONCRETE REVEAL -
SEE ELEVATION
SHEETS.
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
A.1 A
64 MM ROCK WOOL
INSULATION.
FULL FLIGHT
SIMULATOR
Sim
A1
A-523
MODIFIED BITUMEN
ROOFING SYSTEM
HOLD INSULATION
TIGHT TO DECK,
SEAL FLUTES WITH
FOAM INSULATION
REFER WALL
PARTITION TYPES
GENERAL NOTES
FOR INSTALLATION
OF STUDS AT HIGH
WALL CONDITIONS
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE FOUNDATIONS,
REFER STRUCTURE
FOUNDATION PLAN
CONCRETE PERIMETER
BEAM AND WALL, REFER
STRUCTURE ROOF
FRAMING PLAN
EXTERIOR PAVEMENT,
REFER CIVIL SITE
DRAWINGS
DASHED LINE INDICATES
LINE OF AIR BARRIER; REFER
A-131 AND A-132 FOR
COMPONENTS AND NOTES.
PROTECTION BOARD,
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM AND
50MM THICKNESSES(
ON VAPOR BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
MODIFIED BITUMEN
ROOFING.
FACTORY FINISHED
METAL GUTTER.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
12.5 MM GYPSUM
BOARD.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
50 MM STEEL METAL
DECK.
PROTECTION BOARD,
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM
AND 50MM
THICKNESSES), ON
VAPOR BARRIER.
1.1 1
64 MM ROCK WOOL
INSULATION.
FULL FLIGHT
SIMULATOR
ATTACHMENT OF STUDS
AND INSULATION TO
PERIMETER BEAM,
REFER A5/A-525 FOR
TYPICAL (SIMILAR)
CONDITION.
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATION WALL
AND FOOTERS, REFER
STRUCTURE
FOUNDATION PLAN
GYPSUM BOARD
PILASTER BEYOND
HOLD INSULATION TIGHT
TO METAL DECK, SEAL
ALL FLUTES WITH FOAM
INSULATION
DASHED LINE
INDICATES LINE OF
AIR BARRIER;
REFER A-131 AND
A-132 FOR
COMPONENTS AND
NOTES.
CONCRETE WALL AND
PERIMETER BEAM,
REFER STRUCTURE
ROOF FRAMING PLAN
GRADE MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
FACTORY FINISHED
COILING OVERHEAD
DOOR.
FACTORY FINISHED
COILING OVERHEAD
DOOR HOUSING.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
12.5 MM GYPSUM
BOARD.
FACTORY FINISHED
METAL GUTTER.
PROTECTION BOARD,
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM
AND 50MM
THICKNESSES), ON
VAPOR BARRIER.
1.1 1
64 MM ROCK WOOL
INSULATION.
TRENCH DRAIN AND
GRATE.
FULL FLIGHT
SIMULATOR
MODIFIED BITUMEN
ROOFING SYSTEM
50 MM STEEL
METAL DECK
CONCRETE BEAM
AND STEEL FRAMING,
REFER STRUCTURE
ROOF FRAMING PLAN
HOLD INSULATION
TIGHT TO METAL
DECK, SEAL ALL
FLUTES WITH FOAM
INSULATION
FACE OF
PILASTER
BEYOND
CONCRETE WALL
AND BEAM, REFER
TO STRUCTURE
ROOFING PLAN
CONCRETE
FOUNDATIONS AND
FOOTINGS, REFER
STRUCTURE
FOUNDATION PLAN50 MM
PERIMETER
INSULATION
EXTERIOR PAVEMENT,
REFER CIVIL SITE
DRAWINGS
A8
A-526
Sim
E1
A-611
DASHED LINE
INDICATES LINE OF
AIR BARRIER; REFER
A-131 AND A-132 FOR
COMPONENTS AND
NOTES.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
1. SEAL ALL PENETRATIONS OF THE AIR
BARRIER, AND VERIFY INTEGRITY PRIOR
TO COVERING WITH OTHER MATERIALS.
2. FIRST FLOOR ELEVATION OF "0"
CORRESPONDS TO THE DATUM
ELEVATION OF FFE=130.70 ON CIVIL
SITE DRAWINGS.
3. DIMENSIONS SHOWN FOR WINDOW,
LOUVER AND DOOR OPENINGS ARE
ROUGH OPENINGS. REFER TO DOOR,
WINDOW AND LOUVER SCHEDULE
SHEETS SERIES A-600.
4. REFER INTERIOR WALL TYPES A-002
GENERAL NOTES FOR ATTACHMENT OF
STUDS TO CONCRETE AT WALLS ABOVE
3 600 HEIGHT.
5. REFER SHEET A-533 FOR "MISC DETAILS"
AND INFORMATION.
GENERAL NOTES:
SHEET ID
D R
A W
N B
Y
D E
S I G
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L I C
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
PLOT SCALE:PLOT DATE: READY TO ADVERTISE - 06 MARCH 2020
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
PLOTTED BY:
FILE PATH:
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
F Y
M
IL
C
O N
A F
S O
C
S
IM
U L A
T O
R F
A C
IL
IT
Y Y
O K
O T
A A
IR
B
A S
E J A
P A
N
S
IM
U L A
T O
R B
U
IL
D
IN
G
W
H
V -1
-D
- 0
-0
S im u l a to r_
A rc h . r v t
A F
-1
-2
-0
M
A R
C H
As indicated
9/29/2020 5:42:48
PM
BIM 360://AFSOC Vertical Design - Yokota AB/Simulator_Arch.rvt
A H
A U
C K
-K A
L T
I
M .K
G
E N
IS
R K
N O
L L E
A-313
M L
O H
S E
W A
L L S
E C
T
IO
N S
A -3
1 : 20
WALL SECTION
A6
1 : 20
WALL SECTION
A3
1 : 20
WALL SECTION
A1
0 400
SCALE: 1: 20
800200
M A
S
C R
IP
T
IO
N
D A
T E
B id I n q u ir y
-3
-2
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
CLEAR ANODIZED
ALUMINUM COPING.
E
CEILING AS
SCHEDULED.
12.5 MM GYPSUM
BOARD.
64 MM ROCK WOOL
INSULATION.
65 MM METAL STUDS
AT 303MM MAX.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
COMPUTER
ROOM
Sim
A1
A-523
MODIFIED BITUMEN
ROOFING SYSTEM
CONCRETE ROOF SLAB AND
PERIMETER BEAM, REFER
STRUCTURE ROOF FRAMING
PLAN
CONCRETE FLOOR SLAB,
REFER TO STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATION AND
FOOTINGS, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
REVEAL, REFER
ELEVATIONS
CONCRETE
REVEAL, REFER
ELEVATIONS
50 MM RIGID FOUNDATION
PERIMETER INSULATION
DASHED LINE
INDICATES LINE OF
AIR BARRIER; REFER
A-131 AND A-132 FOR
COMPONENTS AND
NOTES.
300 TYP
Sim
A5
A-525
GRADE MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
PROTECTION BOARD,
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM AND
50MM THICKNESSES(
ON VAPOR BARRIER
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
CEILING AS
SCHEDULED.
CONCRETE WALL.
REFER TO
STRUCTURAL WALL
ELEVATIONS.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
65 MM METAL STUDS
AT 303MM MAX.
12.5 MM GYPSUM
BOARD.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
FACTORY FINISHED
METAL FASCIA
PANELS WITH DRIP
EDGE. VERTICAL
JOINTS TO ALIGN WITH
METAL ROOF SEAMS.
F
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
STORAGE
50 MM STEEL METAL
DECK
CONCRETE BEAM AND
WALL, REFER
STRUCTURE ROOF
FRAMING PLAN
CONCRETE
FLOOR SLAB,
REFER
STRUCTURE
FOUNDATION
PLAN
CONCRETE FOOTING
AND FOUNDATION,
REFER STRUCTURE
FOUNDATION PLAN
CERAMIC TILE WITH
MORTAR INSET INTO
WALL. REFER
ELEVATIONS AND
TYPICAL TILE DETAILS
SHEET A-533.
DASHED LINE INDICATES
LINE OF AIR BARRIER;
REFER A-131 AND A-132
FOR COMPONENTS AND
NOTES.
E5
A-525
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD ON
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM AND
50MM THICKNESSES) ON
VAPOR BARRIER
64 MM ROCK WOOL
INSULATION
GRADE MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
FACTORY FINISHED
BLAST-RESISTANT
STOREFRONT SYSTEM
WITH INSULATED
LAMINATED GLAZING.
65 MM METAL STUDS
AT 303MM MAX.
FACTORY FINISHED
STANDING SEAM
METAL ROOF AND
UNDERLAYMENT AS
REQUIRED BY MFR.
FACTORY FINISHED
METAL FASCIA
PANELS WITH DRIP
EDGE. VERTICAL
JOINTS TO ALIGN WITH
METAL ROOF SEAMS.
E.9 F
12.5 MM GYPSUM
BOARD.
64 MM ROCK WOOL
INSULATION.
60 MM RIGID FOAM
BOARD INSULATION
FULLY ADHERED TO
CONCRETE.
CEILING AS
SCHEDULED.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
E1
A-525
GRADE. MINIMUM 150
MM BELOW FIRST
FLOOR SLAB.
CORRIDOR
CO1
A5
A-521
50 MM STEEL METAL
DECK
CONCRETE BEAM AND WALL ,
REFER STRUCTURE ROOF
FRAMING PLAN
HOLD
INSULATION
TIGHT TO DECK,
SEAL FLUTES
WITH FOAM
INSULATION
CONCRETE FLOOR
SLAB, REFER TO
STRUCTURE
FOUNDATION
PLAN
CONCRETE
FOUNDATIONS,
REFER
STRUCTURE
FOUNDATION
PLAN
A1
A-502
DASHED LINE INDICATES
LINE OF AIR BARRIER;
REFER A-131 AND A-132
FOR COMPONENTS AND
NOTES.
E5
A-525
SELF-ADHERING
MEMBRANE ON
PROTECTION BOARD ON
RIGID POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM AND
50MM THICKNESSES) ON
VAPOR BARRIER
ENTRY CANOPY WITH
MODIFIED BITUMEN
ROOFING FINISH AND
METAL PANEL FASCIA,
SOFFIT; REFER PLAN
ON SHEET A-525
ATTACHMENT OF STUDS,
INSULATION TO PERIMETER
BEAM, REFER A5/A-525 FOR
TYPICAL ( SIMILAR) DETAIL.
.15 MM POLY VAPOR
RETARDER UNDER
GYPSUM BOARD
FIRST FLOOR
CLEAR ANODIZED
ALUMINUM COPING.
2.9
HOLLOW METAL DOOR
AND FRAME.
50 MM RIGID
FOUNDATION
PERIMETER
INSULATION.
MECHANICAL
ROOM
M11
C9
A-521
MODIFIED
BITUMEN ROOFING
SYSTEM
CONCRETE ROOF,
BEAM, AND WALLS -
REFER STRUCTURE
ROOF FRAMING
PLAN
INTERIOR WALL TYPE,
GYPSUM BOARD ON
METAL STUDS WITH
ROCK WOOL
INSULATION AND
VAPOR BARRIER
60 MM RIGID
INSULATION
ADHERED TO WALL
CONCRETE FLOOR
SLAB, REFER
STRUCTURE
FOUNDATION PLAN
CONCRETE
FOUNDATIONS, REFER
STRUCTURE
FOUNDATION PLAN
DASHED LINE
INDICATES LINE OF
AIR BARRIER;
REFER A-131 AND
A-132 FOR
COMPONENTS AND
NOTES.
FLEXIBLE JOINT FILLER AT
CONCRETE SIDEWALK, REFER
CIVIL SITE DRAWINGS.
Sim
A5
A-525
PROTECTION BOARD,
RIGID
POLYISOCYANURATE
ROOF INSULATION (1
LAYER EACH 75MM AND
50MM THICKNESSES(
ON VAPOR BARRIER
CONCRETE SIDEWALK, REFER
CIVIL SITE DRAWINGS.
1. SEAL ALL PENETRATIONS OF THE AIR
BARRIER, AND VERIFY INTEGRITY PRIOR
TO COVERING WITH OTHER MATERIALS.
2. FIRST FLOOR ELEVATION OF "0"
CORRESPONDS TO THE DATUM
ELEVATION OF FFE=130.70 ON CIVIL
SITE DRAWINGS.
3. DIMENSIONS SHOWN FOR WINDOW,
LOUVER AND DOOR OPENINGS ARE
ROUGH OPENINGS. REFER TO DOOR,
WINDOW AND LOUVER SCHEDULE
SHEETS SERIES A-600.
4. REFER INTERIOR WALL TYPES A-002
GENERAL NOTES FOR ATTACHMENT OF
STUDS TO CONCRETE AT WALLS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .