ATTACHMENT J-1502000-01
FACILITIES PROPERTY AND SYSTEMS INVENTORY
| Site Code |
| Fac ID |
| Facility Name & Address |
| Building Number |
| Square Footage |
| RQ401 |
| PR024 |
| USARC BLDGS 323, 324, 325, FORT ALLEN, ROAD NO 149, KM 2, JUANA DIAZ |
| 323 |
| 3,913.00 |
| RQ401 |
| PR024 |
| USARC BLDGS 323, 324, 325, FORT ALLEN, ROAD NO 149, KM 2, JUANA DIAZ |
| 324 |
| 4,307.00 |
| RQ401 |
| PR024 |
| USARC BLDGS 323, 324, 325, FORT ALLEN, ROAD NO 149, KM 2, JUANA DIAZ |
| 325 |
| 3,913.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 1 |
| 34,859.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 2 |
| 19,960.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 3 |
| 41,019.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 7 |
| 45.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 17 |
| 3,970.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| 00QH1 |
| 10,921.00 |
| RQ685 |
| PR010 |
| FT ALLEN – LTC HERNAN G. PASQUERA USARC; ROAD NO 149 KM 2, JUANA DIAZ |
| PMPST |
| 162.00 |
J-1502000-01 P0001
ATTACHMENT J-1502000-02
SITE MAPS
| Site Code |
| Site Name |
| Site Address |
| Site Map File Name |
| RQ401 |
| Fort Allen Army Reserve Center |
| Road No. 149, km 2, Juana Diaz |
| RQ401.pdf |
| RQ685 |
| LTC Hernan G. Pesquera Army Reserve Ctr |
| Road No. 149, km 2, Juana Diaz |
| RQ685.pdf |
J-1502000-02 P0001
ATTACHMENT J-1502000-03
PROJECTED SERVICE CALLS
The following table provides the projected number of services calls that should be expected for bidding purposes to occur annually at each of the two sites being added by P0001. The number of projected calls at each site and the mix of HVAC/Other than HVAC, and Emergency/Routine calls may vary. The overall total may vary plus or minus 10% without an equitable adjustment. If the overall total does vary more than plus or minus 10% the equitable adjustment will be based on the ELIN price.
| Site |
| Projected HVAC Service Calls |
| Projected other than HVAC Service Calls |
| Emergency Service Calls |
| Routine Service Calls |
Examples of service calls which might be experience include:
1. HVAC does not work properly.
2. Commode, urinal, sink, water cooler, or shower is stopped up.
3. Water Heater is leaking.
4. Gutter or downspout damaged.
5. Door or door closer is damaged by Government personnel.
6. Broken window either by vandal or government personnel.
In each case the Contractor responds to the site within the specified time limits for either an emergency or routine service call and makes repairs up to the specified service call limit. If the total cost of direct labor and direct material exceeds service call limit the Contractor will provide an assessment and estimated cost to the KO within the specified time frame. The Government may or may not issue multiple service calls or an IDIQ delivery order to complete the repair. See Spec Item 3.1.
J-1502000-03 P0001
ATTACHMENT J-1502000-04
HVAC AND REFRIGERATION SYSTEM INVENTORY
| Facility # |
| Description |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
RQ685-001
Dirty Filter Monitoring Panel – Room 204
RQ685-003
Exterior of bldg (North) Condensing Unit
Desert Aire
Exterior of bldg (North) Condensing Unit
Desert Aire
Interior Air Handler
Interior Air Handler
J-1502000-04 P0001
ATTACHMENT J-1502000-05
TEMPERATURE STANDARDS
| Occupied Living & Working Spaces |
| 74º ± 2º F |
| Unoccupied Living and Working Spaces (Set-Up) |
| 85º ± 5º F |
REFRIGERATION SYSTEMS
| Dairy Products |
| 32º to 34º |
| Fruits and Vegetables |
| 36º to 42º |
J-1502000-05 P0001
ATTACHMENT J-1502000-06
EXHAUST AND TRANSFER FAN INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
| Last Service |
RQ685-001
| Roof top EF |
| 3 |
| EF-15; EF-3 |
| Penn Ventilator |
| DX08SR |
| Roof top EF |
| 1 |
| EF-12/EF-2 |
| Penn Ventilator |
| XQ-82 |
| Roof top EF |
| 1 |
| EF-4 |
| Penn Ventilator |
| XR-94 |
| Roof top EF |
| 1 |
| EF-5 |
| Penn Ventilator |
| FMX-18B |
| Roof top EF |
| 2 |
| EF-6 |
| Penn Ventilator |
| FX16Q |
| Roof top EF |
| 2 |
| SF-2; SF-1 |
| Penn Ventilator |
| MU-40 |
| Roof top EF |
| 2 |
| SF-3 |
| Penn Ventilator |
| MU-30 |
| Roof top EF |
| 1 |
| EF-1 |
| Penn Ventilator |
| AB |
RQ685-002
| Rooftop exhaust fan |
| 4 |
| EF-14 |
| Penn Ventilator |
| Dry/11CM |
| Rooftop exhaust fan |
| 3 |
| EF-20 |
| Rooftop exhaust fan |
| 2 |
| EF-10 |
| Penn Ventilator |
| DX08SR |
| Rooftop exhaust fan |
| 2 |
| EF-1 |
| Loren Cook Co. |
| 100 ACEH |
RQ685-003
| Exhaust Fans w/ Hoods |
| 8 |
| Hood 1-8 |
| Moffitt Corp. |
| HREDC36 |
| 70374 |
Loren Cook Co.
RQ685-00QH1
Schaefer
RQ685-PMPST
Penn Ventilator
J-1502000-06 P0001
ATTACHMENT J-1502000-09
ROOFTOP UNIT INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
| Last Service |
RQ685-001
| Rooftop Single Package Unit |
| 1 |
| Johnson Controls |
| J15ZFC00A4AAC1 |
| N1L0436519 |
| 174,000 BTUH |
| Rooftop Single Package Unit |
| 1 |
| Johnson Controls |
| J15ZJC00D4BZZ10001 B |
| N1G2987739 |
| 174,000 BTUH |
| York |
| YCJF36S41S1 A |
| W1M1418586 |
| Rooftop Single Package Unit |
| 1 |
| Johnson Controls |
| JA5ZJC00R4BZZ50001 A |
| N1G2969917 |
| 60,000 BTUH |
| Rooftop Single Package Unit |
| 1 |
| Johnson Controls |
| J10ZJC00R4BZZ50004 A |
| N1G2987857 |
| 120,000 BTUH |
| Trane |
| TSC120A4R0A2900 |
| 704101686L |
RQ685-002
| Johnson Controls |
| J07ZJC00R4BZZ50002A |
| N1G2005305 |
| 90,000 BTUH |
| Johnson Controls |
| J12ZJC00R4BZZ50001A |
| N1G2001117 |
| 150,000 BTUH |
J-1502000-09 P0001
ATTACHMENT J-1502000-12
HUMIDIFIER INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
| Last Service |
RQ685-002
| Air Compressor Dryer Unit |
| 1 |
Saylor Beall
J-1502000-12 P0001
ATTACHMENT J-1502000-13
MINI-SPLIT INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
| Last Service |
RQ401-324
| Condenser unit (exterior) |
| 1 |
| Ducane |
| 2AC13B60P-2A |
| 4609G59205 |
| 60,000 BTUH |
| Floor-ceiling unit (Room D0) |
| 1 |
| Ducane |
| CAN-60FCT-EV |
| 107170502080300070 |
| 60,000 BTUH |
RQ685-001
| Top of wall mounted, Room 209 |
| 1 |
York
York
RQ685-002
| Condensing Unit/East Wall |
| 1 |
| Nordyne |
| GS3BA-036KA |
| GSA060100590 |
| 36,000 BTUH |
| Condensing Unit/South Wall |
| 1 |
| Nordyne |
| JS5BD-024KA |
| JSF080302105 |
| 24,000 BTUH |
| Elevated wall mount condensing unit |
| 1 |
18,000 BTUH
| TGM |
| MWCT24S |
| 055063796050700012 |
| 24,000 BTUH |
| 2005 |
RQ685-003
| Elevated wall mounted (exterior) condenser |
| 1 |
| Daikin |
| R60BVL |
| 3901116 |
| 23,500 BTUH |
TGM
RQ685-00QH1
SCU10B24A-1
SCU10B48A-1
8400J16354;
8400J16310;
8400H37897;
18,000 24,000 48,000
| Nordyne |
| JS4BD-042KA |
| JSD091203342 |
| 3.5 ton |
Armstrong
| Wall mount cooling unit |
| 1 |
| York |
| YAEC36FS-ADS |
| 1001300171 |
| 36,000 |
J-1502000-13 P0001
ATTACHMENT J-1502000-15
THERMOSTAT INVENTORY
| Facility #: |
| Description |
| Location |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
| Last Service |
RQ685-001
| Wall mounted analog |
| Room 304; 405 |
| 2 |
Colman
| Wall mounted, digital |
| Room 301 |
| 1 |
Johnson Controls
Wall mounted, digital
Johnson Controls
| Wall mounted, digital |
| Room 103 |
| 1 |
Honeywell
| Wall mounted, digital |
| Room 504 |
| 1 |
Honeywell
Wall mounted
QE
RQ685-002
| Wall mounted, digital |
| Corridor 113 |
Johnson Controls
| Wall mounted, digital |
| Room 201 |
Johnson Controls
| Wall mounted analog |
| Room 105 |
| 1 |
Colman
RQ685-003
| Wall mounted thermostat |
| Room 107 |
| 2 |
Honeywell
| Wall mounted relative humidity control |
| Room 107 |
| 2 |
Honeywell
J-1502000-15 P0001
J-1502000-16
SECURITY SYSTEMS AND EQUIPMENT INVENTORY
| Facility # |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
| Last Service |
RQ685-001
| Keypad |
| 5 |
| 1056, 1052, 1054, 1057 |
| Advantor |
| Advantor power supply box |
| 10 |
Advantor
| Exterior security cameras |
| 5 |
| Interior motion detectors |
| 95 |
RQ685-002
| Alarm Keypad |
| 1 |
| 1055 |
| Advantor |
| Access Module |
| 1 |
| 6 |
| Advantor |
| 07140001 |
| Base pluse 1055 & LEM #1 |
| 1 |
| Pelco |
| MCS8-5B |
| 02365-30-0031 21 |
| Motion detectors throughout building. Wall and ceiling mounted |
| 25 |
RQ685-003
| Advantor keypad |
| 1 |
| 1054 |
| Advantor |
| Advantor Security Box |
| 1 |
| ACM #7 |
| Advantor |
| Advantage Plus |
| Advantor Security Box |
| 1 |
| Base Plus 1054 & LEM #1 |
| Advantor |
| Advantage Plus |
| Pelco |
| MCS8-5B |
| 02365-30-0036 14 |
RQ685-00QH1
| Advantor Keypad |
| 1 |
| 1058 |
| Advantor |
| Advantor Base Module |
| 1 |
| Base Plus 1058 |
| Advantor |
| Advantage Plus |
J-1502000-16 P0001
J-1502000-17
COMPRESSED AIR SYSTEMS (FIXED TO BUILDING) INVENTORY
| Facility # |
| Description |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Last Certification |
| Service Frequency |
| Year |
RQ685-002
| 1 |
| Ingersoll Rand |
| Grainger-710 |
| 0703190087 |
J-1502000-17 P0001
J-1502000-18
EMERGENCY GENERATOR SYSTEM INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
| Last Service |
RQ401-324
| Portable generators (fixed) |
| 2 |
| Generac Power Systems |
| 45822 |
| 4487937 |
RQ685-001
| South of building main entrance. Diesel powered |
| 1 |
Caterpillar
J-1502000-18 P0001
J-1502000-19
ABOVE GROUND FUEL STORAGE TANK INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
RQ685-001
| Diesel storage tanks at Generator |
| 2 |
J-1502000-19 P0001
ATTACHMENT J-1502000-21
WEIGHT HANDLING EQUIPMENT (WHE) INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
| Last Service |
| Service Frequency |
RQ685-002
Yale
7.5 tons
J-1502000-21 P0001
J-1502000-22
PLUMBING FIXTURE INVENTORY
| Facility #: |
| Location |
| Type |
| Quantity |
| Last Service |
RQ401-323
| Exterior wall |
| Std. spigot |
| 2 |
| Exterior wall |
| Std. spigot w/ broken handle |
| 1 |
| Rooms A7, B3, C7, D3 |
| Floor mounted Toilet |
| 4 |
| Rooms A7, B3, C7, D3 |
| Wall mounted Sink |
| 4 |
| Rooms A7, B3, C7, D3 |
| Standard, single handle Shower |
| 4 |
| Haws – wall mounted water cooler |
| 1 |
| Halsey-Taylor – wall mounted water cooler |
| 2 |
| Elkay – wall mounted water cooler |
| 1 |
RQ401-324
| Exterior wall |
| Std. spigot |
| 2 |
| Exterior wall |
| Std. spigot w/ broken handle |
| 1 |
| A10, A11, B3, C5 bathroom ,C8, D2 |
| Floor mounted toilet with tank |
| 6 |
| A10, A11, B3, C5 bathroom ,C8, D2 |
| P-trap Lavs |
| 6 |
| A11, B3, C8 |
| Std., Single-handle Shower |
| 3 |
| A2, B2, C2 |
| Wall Mount water cooler |
| 3 |
RQ401-325
| West side of building |
| External Hose Faucet |
| 2 |
| East side of building |
| External Hose Faucet, No handle |
| 1 |
| Room A7 |
| Floor mounted Toilet |
| 1 |
| Room B3 |
| Floor mounted Toilet |
| 1 |
| Room C7 |
| Floor mounted Toilet |
| 1 |
| Room D3 |
| Floor mounted Toilet |
| 1 |
| Rooms A7, B3, C7, D3 |
| Wall mounted, single handle Sink |
| 4 |
| Rooms A7, B3, C7, D3 |
| Standard, single handle Shower |
| 4 |
| Wall mounted – Halsey Taylor water cooler |
| 2 |
| Wall mounted – Haws water cooler |
| 1 |
| Wall mounted – Elkay water cooler |
| 1 |
RQ685-001
| Building exterior |
| Hose bib |
| 4 |
| Room 207 |
| Wall mounted, flush valve Toilet |
| 6 |
| Room 208 |
| Wall mounted, flush valve Toilet |
| 4 |
| Room 502 |
| Wall mounted, flush valve Toilet |
| 3 |
| Room 501 |
| Wall mounted, flush valve Toilet |
| 2 |
| Room 207 |
| Wall mounted, flush valve Urinal |
| 4 |
| Room 502 |
| Wall mounted, flush valve Urinal |
| 2 |
| Room 207 |
| Wall mounted, metered Sink |
| 6 |
| Room 208 |
| Wall mounted, metered Sink |
| 4 |
| Room 502 |
| Wall mounted, metered Sink |
| 3 |
| Room 501 |
| Wall mounted, metered Sink |
| 2 |
| Room 302, 209, 509 |
| P-trap standard Sink |
| 3 |
| Room 305, 306 |
| Double-bowl kitchen sink |
| 2 |
| Room 305 |
| Wall mounted, foot pedal Sink |
| 1 |
| Room 306 |
| Single-bowl, kitchen sink |
| 3 |
| Room 207 |
| Standard single handle Shower |
| 4 |
| Room 208 |
| Standard single handle Shower |
| 2 |
| Exterior corridor and courtyard |
| Wall mounted, Halsey-Taylor Water Cooler |
| 2 |
RQ685-002
| Room 103 |
| Wall mounted, flush valve Toilet |
| 2 |
| Room 105 |
| Wall mounted, flush valve Toilet |
| 2 |
| Room 120 |
| Wall mounted, flush valve Toilet |
| 1 |
| Room 105 |
| Wall mounted, flush valve Urinal |
| 2 |
| Room 103 |
| Wall mounted, flush valve sink |
| 2 |
| Room 105 |
| Wall mounted, flush valve Sink |
| 3 |
| Room 120 |
| Wall mounted, flush valve Sink |
| 1 |
| Room 119 |
| Double-bowl, two-handle Sink |
| 1 |
| Exterior (south wall) |
| Kitchen style wash basin |
| 2 |
| Room 104 |
| Standard, single-handle Shower |
| 1 |
| Corridor 102 |
| Wall mounted Halsey-Taylor water cooler |
| 1 |
RQ685-003
| NE & SW corners |
| Std. spigot |
| 2 |
| Women’s Room 105 |
| Floor mounted, flush valve Toilet |
| 1 |
| Men’s Room 106 |
| Floor mounted, flush valve Toilet |
| 1 |
| Men’s Room 106 |
| Wall mounted, flush valve Urinal |
| 1 |
| Women’s Room 105 |
| Wall mounted, double handle sink |
| 1 |
| Men’s Room 106 |
| Wall mounted, double handle sink |
| 1 |
| Break Room 103 |
| Double-bowl, single handle kitchen sink |
| 1 |
| Women’s Room 105 |
| Standard, double handle shower |
| 1 |
| Men’s Room 106 |
| Standard, double handle shower |
| 1 |
| South wall, Eastern side |
| Wall mounted, Halsey-Taylor water cooler |
| 1 |
RQ685-017
| On concrete islands under roof |
| Water Spigot |
| 2 |
RQ685-00QH1
| Exterior walls |
| Standard spigot |
| 3 |
| Exterior walls |
| Standard spigot w/ broken/missing handle |
| 1 |
| Room 131 |
| Floor mounted, flush valve Toilet |
| 2 |
| Room 132 |
| Floor mounted, flush valve Toilet |
| 1 |
| Room 131 |
| Wall mounted, flush valve Urinal |
| 2 |
| Room 131 |
| Wall mounted double handle Sink |
| 2 |
| Room 132 |
| Wall mounted double handle Sink |
| 2 |
| Room 130 |
| Double-bowl Sink, single handle, counter top |
| 1 |
| Room 131 |
| Standard, single handle Shower |
| 2 |
| Room 132 |
| Standard, single handle Shower |
| 1 |
| Along wall of Room 130 |
| Wall mounted – Halsey-Taylor Water Cooler |
| 1 |
RQ685-PMPST
| East side of building |
| Fire department connection |
| 1 |
J-1502000-22 P0001 J-1502000-23
WATER HEATER INVENTORY
| Facility #: |
| Location |
| Manufacturer |
| Model No |
| Serial No |
| Capacity |
| Year |
| Quantity |
RQ401-323
| A1 |
| Bradford-White |
| M130R5DS13 |
| ME4851861 |
| 30 Gal |
| B1 |
| Bradford-White |
| MI30R5DS13 |
| ME4851860 |
| 30 Gal |
| C1 |
| Bradford-White |
| 1I30R5DS13 |
| ME4851927 |
| 30 Gal |
| D1 |
| Bradford-White |
| MI30R5DS13 |
| ME4852031 |
| 30Gal |
RQ401-324
| A7, B7, & C6 |
| Stiebel Eltron |
| DHC Instantaneous Water Heater |
| --- |
| --- |
| --- |
| 3 |
RQ401-325
| Room A1 |
| Bradford White |
| MI30R5DS13 |
30 Gal
| Room B1 |
| Stiebel Eltron (DHC Instantaneous) |
| DHC 8-2 |
| 074055-8726-000016 |
| 0.131 Gal |
| Room C1 |
| Bradford White |
| MI30R5DS13 |
| ME4851884 |
| 30 Gal |
| Room D1 |
| Stiebel Eltron (DHC Instantaneous) |
| DHC 8-2 |
| 074055-8726-000029 |
| 0.131 Gal |
RQ685-001
| Room 204 |
| A.O. Smith |
| DVE-200-30 |
| SH89-29796-Y3 |
| Room 204 |
| A.O. Smith |
| DVE-200-30 |
| SH89-29795-Y3 |
RQ685-002
| Room 105 |
| Bradford White |
| M265R6DS5 |
| CB7361242 |
| 65 gal |
J-1502000-23 P0001
J-1502000-24
CIRCULATING PUMP INVENTORY
| Facility #: |
| Description |
| Quantity |
| Manufacturer |
| Model No |
| Serial No |
| Capacity |
| Year |
| Last Service |
RQ685-001
J-1502000-24 P0001
J-1502000-25
BACKFLOW PREVENTION DEVICE INVENTORY
| Facility # |
| Description |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
| Last Certification |
RQ685-002
Double check valve
J-1502000-25 P0001
J-1502000-28
WATER TOWER TANK INVENTORY
| Facility # |
| Location |
| Type (Elevated, Round) |
| Model No. |
RQ685-001
| North of building |
| Round, ground based, no tower, about 25ft tall, 28ft diameter, Year-1992, capacity-100000 |
| Alonso & Carus Iron Works, Inc – 1.0 Contract No.: 91-766 |
J-1502000-28 P0001
J-1502000-29
ROOF DRAINS/GUTTERS INVENTORY
| Facility #: |
| Description |
| Quantity |
| Last Service |
RQ685-001
| Roof drains w/ downspouts |
| 32 |
RQ685-002
| Roof drains w/ down spouts |
| 6 |
RQ685-003
| Roof drains w/ downspouts |
| 9 |
RQ685-007
| Parapet drain on East side of roof |
| 1 |
RQ685-017
| Gutter along East side |
| 77ft |
| Downspouts on East side |
| 2 |
RQ685-00QH1
RQ685-PMPST
| Downspouts on West side |
| 2 |
J-1502000-29 P0001
ATTACHMENT J-1502000-30
FIRE PROTECTION SYSTEM INVENTORY - FIRE ALARM SYSTEM OVERVIEW
| Facility #: |
| Type |
| Description |
| # Pull Handles |
| #. Smoke Detectors |
| # Heat Sensors |
| # Flashing Alarms |
| # Fire Panel Board |
| Wired to Fire Department (Y/N) |
| Last Service |
RQ401-323
EST
RQ401-324
EST
RQ401-325
EST
RQ685-001
IntelliKnight
Yes
RQ685-002
Fire-lite Alarms by Honeywell
RQ685-003
Fire-Lite Alarms by Honeywell
RQ685-00QH1
J-1502000-30 P0001
ATTACHMENT J-1502000-31
FIRE SUPPRESSION SYSTEM INVENTORY
| Facility #: |
| Description |
| XMTR |
| Sprinkler System |
| Dry/Wet Chemical |
| CO2 System |
| FM 200 System |
| Fire Hydrant |
| Fire Pumps |
| Last Service |
RQ685-003
Sprinkler system throughout building
Yes
J-1502000-31 P0001
ATTACHMENT J-1502000-33
FIRE ALARM PANEL BOARD INVENTORY
| Facility #: |
| Location |
| Size |
| Make |
| Model # |
| Serial # |
| Last Service |
| Service Frequency |
RQ401-323
A2
RQ401-324
A2
RQ401-325
A2
RQ685-001
Room 103
RQ685-002
Hallway (Room 102)
RQ685-003
South-West side of building
RQ685-00QH1
SE side of building
J-1502000-33 P0001
ATTACHMENT J-1502000-34
KITCHEN EXHAUST HOODS AND DUCTS INVENTORY
| Facility #: |
| Description |
| Fire Suppression System (Wet/Dry) |
| Make |
| Model # |
| Serial # |
| Quantity |
| Operable (Y/N) |
| Last Service |
| Service Frequency |
RQ685-001
| Large hood system, Room 305 |
| Wet |
| Ansul |
| R-102 |
| 5258297 |
Yes
Single hood system, Room 306
RQ685-003
Single stove domestic hood
J-1502000-34 P0001
ATTACHMENT J-1502000-35
SMOKE DETECTOR INVENTORY
| Facility #: |
| Description |
| Make |
| Model # |
| Serial # |
| Quantity |
| Operable (Y/N) |
| Last Service |
RQ401-323
Ceiling mounted
RQ401-324
Ceiling mounted (old)
RQ401-325
Ceiling mounted, throughout building, electrically powered
RQ685-001
Ceiling mounted
RQ685-002
Ceiling mounted
RQ685-003
Ceiling mounted
RQ685-00QH1
Ceiling mounted
RQ685-PMPST
Ceiling mounted
J-1502000-35 P0001
ATTACHMENT J-1502000-38
LIGHTNING AND GROUNDING DEVICES (LIGHTNING RODS, LIGHTNING ARRESTORS, AND GROUNDING SYSTEMS) INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Year |
RQ685-001
| Transformer ground (Rm 405) |
| 1 |
| Transformer ground (Rm 303) |
| 1 |
| Transformer ground (Rm 204) |
| 2 |
RQ685-00QH1
| Lightning Grounding Rod |
| 3 |
| Transformer Dry T10 |
Transformer Dry T9 & Transformer T-8
Unlabeled transformer
J-1502000-38 P0001
J-1502000-39
EXTERIOR LIGHTING PHOTOCELL CONTACTORS AND/OR TIME CLOCK INVENTORY
| Facility #: |
| Description (Photocell/ Time Clock) |
| Location |
| Quantity |
| Last Service |
RQ401-323
| Photocell |
| Exterior wall @ roof (front & back of bldg.) |
| 2 |
RQ401-324
| Photocell |
| Exterior wall @ roof (front & back of bldg.) |
| 2 |
RQ401-325
| Photo cell for exterior lights |
| East/West side of bldg @ eave |
| 2 |
RQ685-001
| Time Clock (disconnected) |
| Room 405 |
| 1 |
J-1502000-39 P0001
J-1502000-40
PRIVATELY OWNED VEHICLE (POV) PARKING AREA LIGHTS INVENTORY
| Facility #: |
| Description |
| Quantity |
| Pole Type (Steel, Wood, etc) |
| Light Type (Halogen, incandescent, etc) |
| Operational Device (Photo Cell Contacts, Time clock, etc ) |
RQ401-324
| Light post with single arm/light |
| 4 |
| Concrete |
| Sodium or Metal Halide |
RQ685-001
| Pole mounted, two-lamp |
| 10 |
| Rounded concrete |
J-1502000-40 P0001
J-1502000-41
MILITARY EQUIPMENT PARKING LIGHTS INVENTORY
| Facility #: |
| Description |
| Quantity |
| Pole Type (Steel, Wood, etc) |
| Light Type (Halogen, incandescent, etc) |
| Operational Device (Photo Cell Contacts, Time clock, etc ) |
RQ685-001
| Pole mounted, two-lamp |
| 5 |
| Rounded concrete |
| Fluorescent T17 |
RQ685-002
| Round post with one lamp |
| 2 |
| Concrete |
| Fluorescent T17 |
| Round post with two lamps |
| 32 |
| Concrete |
| Fluorescent T17 |
| Round post with four lamps |
| 5 |
| Concrete |
| Fluorescent T17 |
J-1502000-41 P0001
J-1502000-42
EMERGENCY LIGHT WALL PACK INVENTORY
| Facility #: |
| Description |
| Quantity |
| Make |
| Model No |
| Serial No |
| Operable (Y/N) |
| Last Service |
RQ685-001
| Wall mounted, interior |
| 21 |
| Wall mounted in exterior corridor |
| 8 |
RQ685-002
| Wall mounted throughout building interior |
| 9 |
Yes
RQ685-003
Yes
RQ685-00QH1
Yes
J-1502000-42 P0001
J-1502000-43
EMERGENCY EXIT SIGN INVENTORY
| Facility #: |
| Description |
| Quantity |
| Operable |
| Last Service |
RQ401-323
| Ceiling mounted, lighted. Dual Lite |
| 12 |
| Yes |
RQ401-324
| Ceiling mounted. backlit emergency exit sign – Dual-Lite |
| 10 |
| Y |
RQ401-325
| Ceiling mounted, illuminated – Dual Lite |
| 12 |
| Yes |
RQ685-001
| Ceiling and wall mounted, illuminated – Dual-Lite |
| 26 |
| Yes |
RQ685-002
| Ceiling mounted, illuminated – Dual Lite |
| 7 |
| Yes |
RQ685-003
| Ceiling mounted, illuminated – Dual-Lite |
| 5 |
| Yes |
RQ685-00QH1
| Dual-Lite – Ceiling and wall mounted, illuminated |
| 8 |
| Yes |
J-1502000-43 P0001
J-1502000-44
GREASE TRAP INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
RQ685-001
| Outside of Kitchen – Rooms 304-306 |
| 1 |
J-1502000-44 P0001
J-1502000-45
GATE INVENTORY
| Facility #: |
| Location |
| Type (Motorized, Manual, Swinging, Cantilever) |
| Motor |
| Manufacturer |
| Model # |
| Serial # |
| Year |
| Last Service |
RQ685-001
| Motor pool lot to West of building |
| Manual, double swing, chainlink, 6 total |
RQ685-002
| Main gate, East entrance |
| Motorized – iron, sliding, 10ft tall |
| Chamberlain Lift Master |
| SL585-150-21-G3 |
| 5010N1839 |
| 2010 |
| Main gate, East entrance |
| Motorized – iron, sliding, 10ft tall |
| Chamberlain Lift Master |
| SL585-150-21-G3 |
| 5010N1838 |
| 2010 |
| Motor pool lot |
| Manual –chainlink with razor wire, double swing, 8ft tall |
| Motor pool lot |
| Manual –chainlink with razor wire, single swing, 8ft tall |
| Motor pool lot |
| Manual –chainlink with razor wire, personnel swing, 8ft tall |
J-1502000-45 P0001
J-1502000-46
FENCE INVENTORY
| Facility #: |
| Location |
| Type |
| Height |
RQ401-324
| West side of site at perimeter |
| 6’ chain-link fence with 1’ of barbed wire |
| 7’ total |
RQ685-001
| To East of building along POV lot perimeter |
| Iron with razor wire |
| 10ft |
| To West of building along motor pool lot perimeter |
| Chainlink with razor wire |
| 8ft |
RQ685-002
| Motor pool lot |
| Chainlink with razor wire |
| 8ft |
| Main gate, East entrance |
| Iron |
| 10ft |
J-1502000-46 P0001
J-1502000-47
OIL WATER SEPARATOR INVENTORY
| Facility #: |
| Description |
| Quantity |
| Equip # |
| Manufacturer |
| Model No. |
| Serial No. |
| Capacity |
| Year |
RQ685-017
| Large concrete pit 20ft x 7ft |
| 1 |
| Large concrete pit 15ft x 7ft |
| 1 |
J-1502000-47 P0001
J-1502000-48
OVERHEAD DOOR INVENTORY
(include Material, Type, Size, and Location)
| Quantity |
| Manual/ Automatic |
| Motor Information (If Automatic Doors) |
| Manufacturer |
| Model # |
| Serial # |
| Year |
RQ685-002
| 16’x14’ steel |
| 16 |
| Automatic |
| Electro Gate Caribbean |
174753FL
RQ685-003
| 16’x16’ steel |
| 4 |
| Automatic |
RQ685-00QH1
| 12’x12’ steel |
| 4 |
| Automatic |
| Lift-Master |
J-1502000-48 P0001
J-1502000-49
AUTOMATED ACCESS CONTROL SYSTEM INVENTORY
| Facility #: |
| Description (Card Readers, CCTV-cameras, recorders, power supplies, computer monitors, etc) |
| Quantity |
RQ685-001
| Main gate monitor and entrance control |
| 1 |
| Master power supply – Pelco |
| 1 |
J-1502000-49 P0001
J-1502000-50
AUTOMATED KEY CONTROL SYSTEM INVENTORY
| Facility #: |
| Type |
| Quantity |
RQ685-002
RQ685-003
RQ685-00QH1
J-1502000-50 P0001
J-1502000-51
VAULT DOOR INVENTORY
| Facility #: |
| Description/Location |
| Quantity |
| Utilized |
RRQ685-001
| Room 402, Mosler – 3170035 |
| 1 |
| Yes |
RQ685-002
J-1502000-51 P0001
J-1502000-52
INTERIOR ROLL-UP DOOR INVENTORY
(include Material, Type, Size, and Location)
| Quantity |
| Manual/ Automatic |
| Motor Information (If Automatic) |
| Manufacturer |
| Model # |
| Serial # |
| Year |
RQ685-001
| Room 305, steel, 11’x4’ |
| 1 |
| Manual |
RQ685-003
J-1502000-52 P0001
ATTACHMENT J-1503050-54
IRRIGATION SYSTEMS
| Facility # |
| Location |
| Control Valves |
| Controllers |
| Wiring |
| Backflow Preventers |
| Sprinkler Heads |
| Riser |
| Incidental Related Components |
| Last Service |
RQ401-323
North End wall
RQ401-325
RQ685-001
Room 204
J-1502000-54 P0001