W912HN-B-4009_DRAWINGS_AMD1.pdf

PDF 4 MB Posted

Attached to
W912HN22B4009 - Repair Maxwell AFB Elementary School Bldg. 538A and 538A1
Solicitation number
W912HN22B4009
Issued by

About this file

This document outlines a planned firm fixed-price construction contract valued at $10,000,000 to repair Maxwell Elementary-Middle School buildings at Maxwell Air Force Base. The U.S. Army Corps of Engineers Savannah District intends to award the contract to repair fire alarms, HVAC systems, floors, lighting, ceilings and roofs at Buildings 538A and 538A1. The work will also include incidental repairs to two restrooms and a corridor in Building 538B. Maxwell Elementary-Middle School, established in 1963, provides educational services for military dependents at Maxwell AFB and Gunter Annex through the Defense Department Education Activity Americas program.

View the file

Other files

File Type Posted
C.04 - Bid Abstract (signed) - W912HN22B4009.pdf PDF
B.08- Solicitation AMD 5-(SF30) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
B.08- Solicitation AMD 5 (Conformed) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
B.08- Solicitation AMD 4 (Conformed) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
B.08- Solicitation AMD 4-(SF30) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-B-4009_FIO_AS-BUILTS.pdf PDF
B.08- Solicitation AMD 3(Conformed) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
B.08- Solicitation AMD 3 (SF30) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-B-4009_DRAWINGS_AMD3.pdf PDF
B.08- Solicitation AMD 2 (Conformed) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-22-B-4009_SPECS_VOL1_AMD2.pdf PDF
W912HN-B-4009_DRAWINGS_AMD2.pdf PDF
B.08- Solicitation AMD 2 (SF30) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-22-B-4009_SPECS_VOL2_AMD2.pdf PDF
B.08- Solicitation AMD 1 (SF30) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-22-B-4009_SPECS_VOL1_AMD1.pdf PDF
B.08- Solicitation AMD 1 (Conformed) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN22B4009 - Site Visit 20220802.pdf PDF
W912HN-22-B-4009_SPECS_VOL2 (1).pdf PDF
B.08- Solicitation (Released) - W912HN22B4009_Repair School Bldgs Maxwell.pdf PDF
W912HN-22-B-4009_SPECS_VOL1 (1).pdf PDF
W912HN-B-4009_DRAWINGS.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N

O

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

D

C

B

A

C A

T E

G O

R Y

C O

D E

A N

S I D

E

F

G

2 3 4 5 6 7 8 9 10

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

JOSE L. MURGUIDO

Reg. AR0010670 June 2022

BIM 360://Maxwell Elementary Middle School SRM/1412_MEMS_SRM_ARCH CENTRAL_V18.rvt

8/11/2022 12:33:35 PM

J U

N E

W H

N B

G -0

.d w g

-7

-0

G-002

S H

E E

T I

N D

E X

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

-3

M a x w e ll

A ir F o rc e B a s e A la b a m a M a x w e ll

E le m e n ta ry M id d le

S c h o o l R e n o v a ti o n

F Y

RTA (READY TO ADVERTISE)

SHEET INDEX MEP (Linked Model Sheets)

WT SHEET NAME DWG FILE NAME 35

S U

B M

IT

T

A L

F

IN

A L

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

M503 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M602 MECHANICAL SCHEDULES

M603 MECHANICAL CALCULATIONS

M604 MECHANICAL CALCULATIONS

M611. MECHANICAL CALCULATIONS

M701 MECHANICAL CONTROLS

M702 MECHANICAL CONTROLS

M703 MECHANICAL CONTROLS

M704 MECHANICAL CONTROLS

M705 MECHANICAL CONTROLS

M705. MECHANICAL CONTROLS

M706 MECHANICAL CONTROLS

M707 MECHANICAL CONTROLS

MD201 MECHANICAL DEMO OVERALL 1ST FLOOR PLAN

MD401F MECHANICAL DEMO ENLARGED 1 ST FLOOR PLAN - AREA F

MD402G MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA G

MD403H MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA H

MD404J MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA J

PLUMBING

P001 PLUMBING SYMBOLS LEGEND

P401F PLUMBING ENLARGED 1ST FLOOR PLAN - AREA F

P402G PLUMBING ENLARGED 1ST FLOOR PLAN - AREA G

P403H PLUMBING ENLARGED 1ST FLOOR PLAN - AREA H

P404J PLUMBING ENLARGED 1ST FLOOR PLAN - AREA J

P410 PLUMBING ENLARGED RESTROOM PLAN

P701 PLUMBING SCHEDULES

P801 PLUMBING DETAILS

PD401F PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA F

PD402G PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA G

PD403H PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA H

PD404J PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA J

SHEET INDEX MEP (Linked Model Sheets)

WT SHEET NAME DWG FILE NAME 35

S U

B M

IT

T

A L

F

IN

A L

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

STRUCTURAL SHEETS

S-001. GENERAL NOTES S-001.dwg X

S-002. GENERAL NOTES S-002.dwg X

S-003. SPECIAL INSPECTIONS NOTES & SCHEDULES S-003.dwg X

S-004. WIND LOAD DATA AND DIAGRAMS S-004.dwg X

S-100. OVERALL PLAN S-100.dwg X

S-101. ENLARGED PLAN 538A WEST S-101.dwg X

S-102. ENLARGED PLAN 538A EAST S-102.dwg X

S-500.. SECTION AND DETAILS S-500.dwg X

FIRE PROTECTION/LIFE SAFETY SHEETS

FA-100.. FIRE ALARM RISER DIAGRAM FA-100..dwg X

FA-101.. FIRE ALARM OPERATION MATRIX FA-101.dwg X

FA-102. FIRE ALARM OVERALL FIRST FLOOR PLAN FA-102.dwg X

FA-401F. FIRE ALARM ENLARGED FIRST FLOOR AREA F FA-401F.dwg X

FA-401G.. FIRE ALARM ENLARGED FIRST FLOOR AREA G FA-401G.dwg X

FA-401H. FIRE ALARM ENLARGED FIRST FLOOR AREA H FA-401H.dwg X

FA-401J FIRE ALARM ENLARGED FIRST FLOOR AREA J FA-401J.dwg X

FA-411 FIRE ALARME ENLARGED FIRST FLOOR DEMOLITION FA-411.dwg X

FS-401F FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA F FS-401F.dwg X

FS-401G FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA G FS-401G.dwg X

FS-401H FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA H FS-401H.dwg X

FS-401J FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA J FS-401J.dwg X

LS-401F LIFE SAFETY ENLARGED FIRST FLOOR AREA F LS-401F.dwg X

LS-401G LIFE SAFETY ENLARGED FIRST FLOOR AREA G LS-401G.dwg X

LS-401H LIFE SAFETY ENLARGED FIRST FLOOR AREA H LS-401H.dwg X

LS-401J LIFE SAFETY ENLARGED FIRST FLOOR AREA J LS-401J.dwg X

ELECTRICAL

E001 ELECTRICAL SYMBOLS LEGEND

E002 LIGHTING FIXTURE SCHEDULE

E003 ELECTRICAL SYSTEMS SYMBOL LEGEND

E101 ELECTRICAL SITE PLAN

E201 LIGHTING OVERALL CEILING PLAN

E301 ELECTRICAL OVERALL PLAN

E401F LIGHTING ENLARGED CEILING PLAN - AREA F

E402G LIGHTING ENLARGED CEILING PLAN - AREA G

E403H LIGHTING ENLARGED CEILING PLAN - AREA H

E404J LIGHTING ENLARGED CEILING PLAN - AREA J

E405G PHOTOMETRIC ENLARGED PLAN - AREA G

E406H PHOTOMETRIC ENLARGED PLAN - AREA H

E407J PHOTOMETRIC ENLARGED PLAN - AREA J

E408 PHOTOMETRIC TABLES

E409F ELECTRICAL ENLARGED PLAN - AREA F

E410G ELECTRICAL ENLARGED PLAN - AREA G

E411H ELECTRICAL ENLARGED PLAN - AREA H

E412J ELECTRICAL ENLARGED PLAN - AREA J

E501 ELECTRICAL ONE-LINE DIAGRAMS

E601 ELECTRICAL FEEDER SCHEDULES

E701 ELECTRICAL PANEL SCHEDULES

E801 ELECTRICAL DETAILS

E802 ELECTRICAL DETAILS

E803 ELECTRICAL DETAILS

E804 ELECTRICAL DETAILS

E805 ELECTRICAL DETAILS

E806 ELECTRICAL DETAILS

E807 ELECTRICAL RACK ELEVATION

ED401G LIGHTING ENLARGED DEMO PLAN - AREA G

ED402H LIGHTING ENLARGED DEMO PLAN - AREA H

ED403J LIGHTING ENLARGED DEMO PLAN - AREA J

ED404G POWER ENLARGED DEMO PLAN - AREA G

ED405H POWER ENLARGED DEMO PLAN - AREA H

ED406J POWER ENLARGED DEMO PLAN - AREA J

MECHANICAL

M001 MECHANICAL SYMBOLS LEGEND

M002 MECHANICAL GENERAL NOTES

M201 MECHANICAL OVERALL 1ST FLOOR PLAN

M203 MECHANICAL OVERALL ROOF PLAN

M301. MECHANICAL ISOMETRICS AND ENLARGED MECH ROOM

M302 MECHANICAL ENLARGED PLANS

M401F MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA F

M402G MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA G

M403H MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA H

M404J MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA J

M501 MECHANICAL DETAILS

M502 MECHANICAL DETAILS

SHEET INDEX

SHEET ID SHEET NAME DWG FILE NAME 35

S U

B M

IT

T

A L

F

IN

A L

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

GENERAL SHEETS

G-001 COVER SHEET G-001.dwg X

G-002 SHEET INDEX G-002.dwg X

G-005 GENERAL NOTES, ABBREVIATIONS, LEGENDS, AND PROJECT INFORMATION G-005.dwg X

G-006 OVERALL, BASE, AND SCHOOL LOCATION MAPS G-006.dwg X

ARCHITECTURAL SHEETS

AD101 OVERALL DEMOLITION PLAN AD101.dwg X

AD102 EXISTING CONDITION REFERENCE IMAGES AD102.dwg X

AD102A REFERENCE IMAGES (ROOF) AD102A.dwg X

AD105 OVERALL ROOF DEMOLITION PLAN AD105.dwg X

AD111 OVERALL FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION AD111.dwg X

AD401F ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA F AD401F.dwg X

AD401G ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA G AD401G.dwg X

AD401H ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA H AD401H.dwg X

AD401J ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA J AD401J.dwg X

AD403G ENLARGED ROOF DEMOLITION - AREA G AD403G.dwg X

AD403H ENLARGED ROOF DEMOLITION - AREA H AD403H.dwg X

AD403J ENLARGED ROOF DEMOLITION - AREA J AD403J.dwg X

AD411F ENLARGED FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION - AREA F AD411F.dwg X

AD411G ENLARGED FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION - AREA G AD411G.dwg X

AD411H ENLARGED FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION - AREA H AD411H.dwg X

AD411J ENLARGED FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION - AREA J AD411J.dwg X

AE001 WALL & PARTITION TYPE LEGEND AE001.dwg X

AE101 OVERALL FIRST FLOOR PLAN AE101.dwg X

AE104 OVERALL ROOF PLAN AE104.dwg X

AE105 ENLARGED ROOF PLAN AE104.dwg X

AE106 ROOF GENERAL NOTES AND SCOPE OF WORK AE106.dwg X

AE111 OVERALL FIRST FLOOR REFLECTED CEILING PLAN AE111.dwg X

AE401F ENLARGED FIRST FLOOR PLAN - AREA F AE401F.dwg X

AE401G ENLARGED FIRST FLOOR PLAN - AREA G AE401G.dwg X

AE401H ENLARGED FIRST FLOOR PLAN - AREA H AE401H.dwg X

AE401J ENLARGED FIRST FLOOR PLAN - AREA J AE401J.dwg X

AE404G ENLARGED ROOF PLAN - AREA G AE404G.dwg X

AE404H ENLARGED ROOF PLAN - AREA H AE404H.dwg X

AE404J ENLARGED ROOF PLAN - AREA J AE404J.dwg X

AE411F ENLARGED FIRST FLOOR REFLECTED CEILING PLAN - AREA F AE411F.dwg X

AE411G ENLARGED FIRST FLOOR REFLECTED CEILING PLAN - AREA G AE411G.dwg X

AE411H ENLARGED FIRST FLOOR REFLECTED CEILING PLAN - AREA H AE411H.dwg X

AE411J ENLARGED FIRST FLOOR REFLECTED CEILING PLAN - AREA J AE411J.dwg X

AE520 ROOF DETAILS AE520.dwg X

AE521 ROOF DETAILS AE520.dwg X

AE522 ROOF DETAILS AE521.dwg X

AE523 ROOF DETAILS AE522.dwg X

AE524 ROOF DETAILS AE523.dwg X

AE525 ROOF DETAILS AE524.dwg X

AE526 ROOF DETAILS AE526.dwg X

AE527 ROOF DETAILS AE527.dwg X

AE528 ROOF DETAILS AE528.dwg X

AE529 ROOF DETAILS AE529.dwg X

AE530 ROOF DETAILS AE530.dwg X

AE531 ROOF DETAILS AE531.dwg X

AE540 ROOF DETAILS AE540.dwg X

AE541 ROOF DETAILS AE541.dwg X

AE601 FIRST FLOOR DOOR & FRAME TYPES & SCHEDULE AE601.dwg X

AE580 FIRE PENETRATION DETAILS AE580.dwg X

AE581 FIRE PENETRATION DETAILS AE581.dwg X

INTERIOR SHEETS

IF010 MILLWORK SECTIONS IF010.dwg X

IF410 ENLARGED TOILET ROOM PLANS AND ELEVATIONS IF411.dwg X

IF411 ENLARGED TOILET ROOM PLANS AND ELEVATIONS IF411.dwg X

IF430 ENLARGED MILLWORK ELEVATIONS IF430.dwg X

IN001 INTERIOR FINISH LEGEND AND DETAILS IN001.dwg X

IN101 OVERALL FIRST FLOOR FINISH PLAN IN101.dwg X

IN401F ENLARGED FIRST FLOOR FINISH PLAN- AREA F IN401F.dwg X

IN401G ENLARGED FIRST FLOOR FINISH PLAN- AREA G IN401G.dwg X

IN401H ENLARGED FIRST FLOOR FINISH PLAN- AREA H IN401H.dwg X

IN401J ENLARGED FIRST FLOOR FINISH PLAN - AREA J IN401J.dwg X

IN601 FIRST FLOOR ROOM FINISH SCHEDULE IN601.dwg X

I-001 INTERIOR SIGNAGE LEGEND I-002.dwg X

I-002 SIGNAGE SCHEDULE I-001.dwg X

I-101 OVERALL FIRST FLOOR SIGNAGE PLAN I-101.dwg X

I-401F ENLARGED FIRST FLOOR SIGNAGE PLAN- AREA F I-401F.dwg X

I-401G ENLARGED FIRST FLOOR SIGNAGE PLAN - AREA G I-401G.dwg X

I-401H ENLARGED FIRST FLOOR SIGNAGE PLAN - AREA H I-401H.dwg X

I-401J ENLARGED FIRST FLOOR SIGNAGE PLAN - AREA J I-401J.dwg X

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A U

G

SHEET INDEX MEP (Linked Model Sheets)

WT SHEET NAME DWG FILE NAME 3

S U

B M

IT

T

A L

F

IN

A L

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

M503 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M602 MECHANICAL SCHEDULES

M603 MECHANICAL CALCULATIONS

M604 MECHANICAL CALCULATIONS

M611. MECHANICAL CALCULATIONS

M701 MECHANICAL CONTROLS

M702 MECHANICAL CONTROLS

M703 MECHANICAL CONTROLS

M704 MECHANICAL CONTROLS

M705 MECHANICAL CONTROLS

M705. MECHANICAL CONTROLS

M706 MECHANICAL CONTROLS

M707 MECHANICAL CONTROLS

MD201 MECHANICAL DEMO OVERALL 1ST FLOOR PLAN

MD401F MECHANICAL DEMO ENLARGED 1 ST FLOOR PLAN - AREA F

MD402G MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA G

MD403H MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA H

MD404J MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA J

PLUMBING

P001 PLUMBING SYMBOLS LEGEND

P401F PLUMBING ENLARGED 1ST FLOOR PLAN - AREA F

P402G PLUMBING ENLARGED 1ST FLOOR PLAN - AREA G

P403H PLUMBING ENLARGED 1ST FLOOR PLAN - AREA H

P404J PLUMBING ENLARGED 1ST FLOOR PLAN - AREA J

P410 PLUMBING ENLARGED RESTROOM PLAN

P701 PLUMBING SCHEDULES

P801 PLUMBING DETAILS

PD401F PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA F

PD402G PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA G

PD403H PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA H

PD404J PLUMBING DEMO ENLARGED 1ST FLOOR PLAN - AREA J

SHEET INDEX MEP (Linked Model Sheets)

WT SHEET NAME DWG FILE NAME 3

S U

B M

IT

T

A L

F

IN

A L

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

STRUCTURAL SHEETS

S-001. GENERAL NOTES S-001.dwg X

S-002. GENERAL NOTES S-002.dwg X

S-003. SPECIAL INSPECTIONS NOTES & SCHEDULES S-003.dwg X

S-004. WIND LOAD DATA AND DIAGRAMS S-004.dwg X

S-100. OVERALL PLAN S-100.dwg X

S-101. ENLARGED PLAN 538A WEST S-101.dwg X

S-102. ENLARGED PLAN 538A EAST S-102.dwg X

S-500.. SECTION AND DETAILS S-500.dwg X

FIRE PROTECTION/LIFE SAFETY SHEETS

FA-100.. FIRE ALARM RISER DIAGRAM FA-100..dwg X

FA-101.. FIRE ALARM OPERATION MATRIX FA-101.dwg X

FA-102. FIRE ALARM OVERALL FIRST FLOOR PLAN FA-102.dwg X

FA-401F. FIRE ALARM ENLARGED FIRST FLOOR AREA F FA-401F.dwg X

FA-401G.. FIRE ALARM ENLARGED FIRST FLOOR AREA G FA-401G.dwg X

FA-401H. FIRE ALARM ENLARGED FIRST FLOOR AREA H FA-401H.dwg X

FA-401J FIRE ALARM ENLARGED FIRST FLOOR AREA J FA-401J.dwg X

FA-411 FIRE ALARME ENLARGED FIRST FLOOR DEMOLITION FA-411.dwg X

FS-401F FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA F FS-401F.dwg X

FS-401G FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA G FS-401G.dwg X

FS-401H FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA H FS-401H.dwg X

FS-401J FIRE SUPPRESSION ENLARGED FIRST FLOOR AREA J FS-401J.dwg X

LS-401F LIFE SAFETY ENLARGED FIRST FLOOR AREA F LS-401F.dwg X

LS-401G LIFE SAFETY ENLARGED FIRST FLOOR AREA G LS-401G.dwg X

LS-401H LIFE SAFETY ENLARGED FIRST FLOOR AREA H LS-401H.dwg X

LS-401J LIFE SAFETY ENLARGED FIRST FLOOR AREA J LS-401J.dwg X

ELECTRICAL

E001 ELECTRICAL SYMBOLS LEGEND

E002 LIGHTING FIXTURE SCHEDULE

E003 ELECTRICAL SYSTEMS SYMBOL LEGEND

E101 ELECTRICAL SITE PLAN

E201 LIGHTING OVERALL CEILING PLAN

E301 ELECTRICAL OVERALL PLAN

E401F LIGHTING ENLARGED CEILING PLAN - AREA F

E402G LIGHTING ENLARGED CEILING PLAN - AREA G

E403H LIGHTING ENLARGED CEILING PLAN - AREA H

E404J LIGHTING ENLARGED CEILING PLAN - AREA J

E405G PHOTOMETRIC ENLARGED PLAN - AREA G

E406H PHOTOMETRIC ENLARGED PLAN - AREA H

E407J PHOTOMETRIC ENLARGED PLAN - AREA J

E408 PHOTOMETRIC TABLES

E409F ELECTRICAL ENLARGED PLAN - AREA F

E410G ELECTRICAL ENLARGED PLAN - AREA G

E411H ELECTRICAL ENLARGED PLAN - AREA H

E412J ELECTRICAL ENLARGED PLAN - AREA J

E501 ELECTRICAL ONE-LINE DIAGRAMS

E601 ELECTRICAL FEEDER SCHEDULES

E701 ELECTRICAL PANEL SCHEDULES

E801 ELECTRICAL DETAILS

E802 ELECTRICAL DETAILS

E803 ELECTRICAL DETAILS

E804 ELECTRICAL DETAILS

E805 ELECTRICAL DETAILS

E806 ELECTRICAL DETAILS

E807 ELECTRICAL RACK ELEVATION

ED401G LIGHTING ENLARGED DEMO PLAN - AREA G

ED402H LIGHTING ENLARGED DEMO PLAN - AREA H

ED403J LIGHTING ENLARGED DEMO PLAN - AREA J

ED404G POWER ENLARGED DEMO PLAN - AREA G

ED405H POWER ENLARGED DEMO PLAN - AREA H

ED406J POWER ENLARGED DEMO PLAN - AREA J

MECHANICAL

M001 MECHANICAL SYMBOLS LEGEND

M002 MECHANICAL GENERAL NOTES

M201 MECHANICAL OVERALL 1ST FLOOR PLAN

M203 MECHANICAL OVERALL ROOF PLAN

M301. MECHANICAL ISOMETRICS AND ENLARGED MECH ROOM

M302 MECHANICAL ENLARGED PLANS

M401F MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA F

M402G MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA G

M403H MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA H

M404J MECHANICAL ENLARGED 1ST FLOOR PLAN - AREA J

M501 MECHANICAL DETAILS

M502 MECHANICAL DETAILS

MD201 MECHANICAL DEMO OVERALL 1ST FLOOR PLAN

MD401F MECHANICAL DEMO ENLARGED 1 ST FLOOR PLAN - AREA F

MD402G MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA G

MD403H MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA H

MD404J MECHANICAL DEMO ENLARGED 1ST FLOOR PLAN - AREA J

PLAN NORTH

F

E

D

C

B

A

K

G H

J

L

SRM

Renovation Bldg 538A

Zone 1

538B

538B1

538B2

538A Zone 2

538A.1

Zone 3

Zone 4

CORRIDOR

SOCIAL

STUDIES /

HISTORY

SCIENCE

CLASSROOM

MATH /

ELEM

STEM

TECH /

STEM

SOCIAL

STUDIES /

SCIENCE

MATH /

AVID

ELA

MIDDLE

SCHOOL

SCIENCE

MIDDLE

SCHOOL

COUNSELOR

TOILET

002A

TOILET

004A

VESTIBULE

V002

TOILET

001A

TOILET

003A

VESTIBULE

V001

MECH.

ROOM

010A

CURRICULUM

MATERIALS

ROOM

SUPPLY

ROOM

STORAGE

012A

CORRIDOR

1H02

STAFF

WORKROOM

/ LOUNGE

COUNSELOR

OFFICE

OFFICE

OFFICE

011A

WORK/

COPY

015C

TOILET

015B

OFFICE

015A

RESTROOM

015D

1 7 11

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

TOILET

006A

TOILET

008A

VESTIBULE

V006

1/ A

D

1G

1/ A

D

1H

SCOPE BOUNDARY

SCOPE BOUNDARY

S C

O P

E B

O U

N D

A R

Y

6 84

B3/ AD102

CORRIDOR

1H02

B6/ AD102

A3/ AD102

E1/ AD102

E1/ AD102

S C

O P

E B

O U

N D

A R

Y

S C

O P

E B

O U

N D

A R

Y

DEMOLITION NOTES

1. DEMOLITION DRAWINGS ARE ONLY TO ASSIST IN SHOWING THE SCOPE OF

DEMOLITION WORK AND IT IS NOT INTENDED TO INDICATE ALL DEMOLITION.

CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE

WORK.

2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL

BE RESPONSIBLE FOR PERFORMING A WALK THROUGH OF THE PROJECT TO

IDENTIFY POSSIBLE CRITICAL ITEMS NOT OR INCORRECTLY ADDRESSED, WHICH

REQUIRE REMOVAL / RELOCATION PRIOR TO SUBMITTING A BID TO THE OWNER.

3. CONTRACTOR IS TO COORDINATE LOCATION OF ALL TEMPORARY DUST AND

PROTECTION BARRIERS TO MAINTAIN SAFE ACCESS TO EGRESS AT ALL TIMES.

CONSTRUCTION IAQ MANAGEMENT PLAN SHALL BE POSTED AT ALL TIMES.

4. CUT, REMOVE, PATCH, AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO

LEAVE WORK COMPLETE AND IN SATISFACTORY CONDITION.

5. CONTRACTOR IS TO PROTECT ALL CONCEALED UTILITIES. CONTRACTOR IS TO

INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES.

MECHANICAL AND / OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED.

6. RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE

IMMEDIATE SCOPE OF WORK IN VARIOUS AREAS WITHIN THE SCOPE. IT MAY REQUIRE

WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL, COMMUNICATIONS, DATA,

WATER, SEWER, FIRE SPRINKLER PROTECTION, ETC.). ANY WORK IN AREAS OUTSIDE

OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL-INCLUSIVE, PROVIDING ALL

UTILITIES, FINISHES AND EQUIPMENT REQUIRED TO RESTORE THE AREA TO FULLY

OPERATIONAL CONDITIONS.

7. CONTRACTOR IS TO PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY

DEMOLITION AND / OR INSTALLATION OF NEW MECHANICAL DUCT AND ELECTRICAL

CONDUITS ETC. AS REQUIRED, TO MATCH ADJACENT SURFACES AND / OR AS

REQUIRED FOR NEW SCHEDULED FINISHES.

8. FOR REMOVAL OF FIXTURES AND EQUIPMENT, REFER TO ARCHITECTURAL,

MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

9. REFER TO ELECTRICAL DRAWINGS FOR REMOVAL OF ANY ELECTRICAL PANELS,

OUTLETS, ETC.

10. ALL AREAS OF DEMOLITION OPERATIONS SHALL BE PROPERLY POSTED WITH SIGNS

WARNING OF DANGER. SUFFICIENT WATCH PERSONS SHALL BE PROVIDED TO WARN

WORKERS OF IMPENDING DANGERS, AND ALL UNAUTHORIZED PERSONS SHALL BE

EXCLUDED FROM PLACES WHERE DEMOLITION IS IN PROGRESS.

11. PROTECT ALL STRUCTURAL MEMBERS AS REQUIRED.

12. SCOPE OF REQUIRED SLAB CUTTING, REMOVAL AND REPAIR IS NOT INDICATED.

CONTRACTOR REQUIRED TO COORDINATE WILL ALL EXISTING AS-BUILT DRAWINGS

AND DESIGN DRAWINGS TO DETERMINE REQUIREMENTS FOR FULLY FUNCTIONING

SYSTEMS.

13. REMOVE ALL INTERIOR ROOM NAME SIGNAGE FOR NEW ROOM SIGNAGE TO BE

PROVIDED AND INSTALLED IN SCOPE OF RENOVATION WORK. SEE ID DWGS.

14. EXISTING GLAZED WALL TILE ON CORRIDORS TO REMAIN. PROTECT AS REQUIRED.

15. DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION PROTECT EXISTING

TELECOM RACKS, UPS, CABLES, CABLES/BUNDLES FROM DUST/DEBRIS/PAINT. ALL

DISTURBED, DAMAGED OR IMPARED CABLES AND OUTLETS SHALL BE PROVIDED NEW

CABLING AS REQUIRED AND TESTED TO CONFIRM LIKE NEW CONDITION AND

OPERATION.

DEMOLITION PLAN KEY NOTES

1 REMOVE EXISTING CONCRETE BLOCK WALL OR FRAMED WALL AND FINISH.

DEMOLISH FROM TOP OF EXISTING FLOOR SLAB INCLUDING TIE BEAM. PATCH &

REPAIR AS REQUIRED. (SEE STRUCTURAL DWGS.)

2 REMOVE EXISTING MECHANICAL UNIT AND ASSOCIATED COMPONENTS. PATCH AND

REPAIR AS REQUIRED . PREPARE EXISTING WALL SURFACES TO REMAIN TO

RECEIVE NEW FINSHES. (SEE MECHANICAL DRAWINGS)

3 REMOVE PORTIONS OR ALL OF EXISTING INTERIOR WALL PARTITIONS AS INDICATED

ON NEW FLOOR PLANS. PATCH & REPAIR AS REQUIRED TO MATCH EXISTING

ADJACENT CONDITIONS.

5 EXISTING CHILLERS. CONTRACTOR TO COORDINATE WITH REQUIRED PHASING AND

ENGINEERING REQUIREMENTS.

6 REMOVE EXISTING CEILINGS INCLUDING, BUT NOT LIMITED TO, ACOUSTIC CEILING

TILE GRIDS, SOFFITS, LIGHTING FIXTURES, MECHANICAL VENTS, AND CEILING

MOUNTED EQUIPMENTS. EXISTING SPRINKLER SYSTEM TO REMAIN, PROTECT AS

REQUIRED.

7 REMOVE EXISTING CASEWORK AND ASSOCIATED COMPONENTS INCLUDING, BUT

NOT LIMITED TO, BASE AND/OR UPPER CABINETS, COUNTERTOPS, SINKS, WATER

AND GAS PIPING (CAP AND CLOSE AS REQUIRED), ELECTRICAL (IF APPLICABLE),

AND SHELVES. PREPARE EXISTING FLOOR AND WALL SURFACES TO REMAIN TO

RECEIVE NEW FINISHES.

8 REMOVE ALL FLOORING, BASES, AND ACCESSORIES, DOWN TO EXISTING CONC.

SLAB. CONTRACTOR TO VERIFY CONDITION OF EXISTING FLOOR SLAB AND PATCH

AND REPAIR IF NEEDED. PREPARE ALL DEMOLISHED AREAS TO RECEIVE NEW

FINISHES.SEE ID SHEETS/SPECS FOR DETAILS.

4 PREPARE EXISTING INTERIOR WALLS TO RECEIVE NEW FINISHES. NO ITEMS SHOULD

BE REMOVED FROM THE WALL. ALL WORK INCLUDING PAINT WORK SHOULD BE

DONE AROUND ALL EXISTING ELEMENTS ON THE WALL. PROTECT ELEMENTS AS

REQUIRED. PATCH & REPAIR AS REQUIRED.

9 REMOVE AND DISPOSE OF EXISTING FURNITURE, FIXTURES AND EQUIPMENT NOT

REMOVED BY THE OWNER.CONTRACTOR TO COORDINATE REQUIREMENTS FOR

DISPOSAL.

10 EXISTING SINKS TO BE REMOVED. PREPARE FOR NEW SINKS IN THE SAME

LOCATION.

12 REMOVE ALL FLOOR BASES. EXISTING FLOOR FINISH TO REMAIN. CLEAN AND

PREPARE TO RECEIVE NEW FINISH ON TOP OF EXISTING FLOOR FINISH (REFER TO

ENVIRONMENTAL REPORT)

13 EXISTING DOOR AND FRAME TO BE REMOVED. PATCH & REPAIR AS REQUIRED.

(SEE STRUCTURAL DWGS.)

11 REFER TO PLUMBING DRAWINGS FOR EXISTING PLUMBING FIXTURES AND UTILITY

LINES TO BE RELOCATED OR REMOVED. PROVIDE SLAB CUTS AS REQUIRED TO

CONNECT NEW SERVICES, WHERE NECESSARY. CONTRACTOR TO VERIFY EXISTING

LOCATIONS AND DEMOLISH ACCORDINGLY. PATCH AND REPAIR TO RECEIVE NEW

FINISHES.

14 EXISTING GLAZED WALL TILE IN CORRIDORS TO REMAIN. (PROTECT AS REQUIRED)

15 EXISTING MECHANICAL/ELECTRICAL ROOM.SEE MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS FOR SYSTEMS DEMOLITION REQUIREMENTS.

16 EXISTING STAGE TO BE PROTECTED AND PREPARED TO BE SANDED AND

RE-STAINED/VARNISHED. WALLS AND HANDRAIL TO BE PAINTED. (SEE FINISH

DWGS.) PROTECT ALL SYSTEMS, CURTAINS, ETC. AS REQUIRED.

EXISTING WALL

SCOPE BOUNDARY

ITEMS TO BE DEMOLISHED

17 EXISTING DRINKING FOUNTAIN TO REMAIN. (PROTECT AS REQUIRED.)

18 PREPARE WALL AS REQUIRED TO RECEIVE NEW FIRE ALARM PANEL (SEE FIRE

ALARM AND SYSTEM DRAWINGS.)

LEGEND

19 REMOVE EXISTING TEMPORARY WALL AND REPAIR / PREPARE TO LIKE NEW

CONDITION TO RECEIVE NEW FINISHES.

20 RELOCATE TEMPORARY (PHASING) DOOR ASSEMBLY AT CORRIDOR ALONG WITH

FRAMED AND FINISHED PARTITION TO SEPARATE SCOPE AREAS.

21 EXISTING FLOOR FINISH TO REMAIN. PAINT WALL AS REQUIRED - SEE FINISH PLANS.

(PROTECT AS REQUIRED)

22 REMOVE ALL EXISTING FLOORING, EXCEPT UNDER RACKS/UPS . CUT FLOORING

AROUND THE BASE OF THE RACKS AND UPS. REMOVE ALL EXISTING FLOORING,

EXCEPT UNDER RACKS/UPS . CUT FLOORING AROUND THE BASE OF THE RACKS

AND UPS. PROTECT TELECOM RACKS, UPS, AND CABLES/BUNDLES FROM

DUST/DEBRIS/PAINT DURING DEMOLITION AND RENOVATION .

SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

D

C

B

A

C A

T E

G O

R Y

C O

D E

A N

S I D

E

F

G

2 3 4 5 6 7 8 9 10

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

JOSE L. MURGUIDO

Reg. AR0010670 June 2022

BIM 360://Maxwell Elementary Middle School SRM/1412_MEMS_SRM_ARCH CENTRAL_V18.rvt

8/11/2022 12:33:15 PM

J U

N E

W H

N B

A D

G

.d w g

-7

-0

AD401G

E N

L A

R G

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

A R

E A

G

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

-3

M a x w e ll

A ir F o rc e B a s e A la b a m a M a x w e ll

E le m e n ta ry M id d le

S c h o o l R e n o v a ti o n

F Y

RTA (READY TO ADVERTISE)

04 8 16268

SCALE: 1/8"=1'-0"

1/8" = 1'-0"AD401G

A2 ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A U

G

CORRIDOR

1H02

MULTI-PURPOSE

MECHANICAL

ROOM

M16

RESTROOM

016A

JANITOR

J016

SERVER

ROOM

017A

OFFICE

017B

MEDIA

CENTER

MEDIA

ART

CLASSROOM

RESTROOM

016B

EDUCATIONAL

TECH

OFFICE

CORRIDOR

1H02

MUSIC

BAND

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 8

6 84

6 84

6 84

1/ A

D

1G

1/ A

D

1H

1/ A

D

1H

1/ A

D

1J

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

A

E A

S T

S C

O P

E

A

W E

S T

S C

O

STAGE

014A

B1/ AD102

E1/ AD102

A1/ AD102

E3/ AD102

17 17

14 14

S C

O P

E B

O U

N D

A R

Y

SCOPE BOUNDARY

21 6

PLAN NORTH

F

E

D

C

B

A

K

G H J

L

SRM

Renovation Bldg 538A

Zone 1

538B

538B1

538B2

538A Zone 2

538A.1

Zone 3

Zone 4

DEMOLITION PLAN KEY NOTES

1 REMOVE EXISTING CONCRETE BLOCK WALL OR FRAMED WALL AND FINISH.

DEMOLISH FROM TOP OF EXISTING FLOOR SLAB INCLUDING TIE BEAM. PATCH &

REPAIR AS REQUIRED. (SEE STRUCTURAL DWGS.)

2 REMOVE EXISTING MECHANICAL UNIT AND ASSOCIATED COMPONENTS. PATCH AND

REPAIR AS REQUIRED . PREPARE EXISTING WALL SURFACES TO REMAIN TO

RECEIVE NEW FINSHES. (SEE MECHANICAL DRAWINGS)

3 REMOVE PORTIONS OR ALL OF EXISTING INTERIOR WALL PARTITIONS AS INDICATED

ON NEW FLOOR PLANS. PATCH & REPAIR AS REQUIRED TO MATCH EXISTING

ADJACENT CONDITIONS.

5 EXISTING CHILLERS. CONTRACTOR TO COORDINATE WITH REQUIRED PHASING AND

ENGINEERING REQUIREMENTS.

6 REMOVE EXISTING CEILINGS INCLUDING, BUT NOT LIMITED TO, ACOUSTIC CEILING

TILE GRIDS, SOFFITS, LIGHTING FIXTURES, MECHANICAL VENTS, AND CEILING

MOUNTED EQUIPMENTS. EXISTING SPRINKLER SYSTEM TO REMAIN, PROTECT AS

REQUIRED.

7 REMOVE EXISTING CASEWORK AND ASSOCIATED COMPONENTS INCLUDING, BUT

NOT LIMITED TO, BASE AND/OR UPPER CABINETS, COUNTERTOPS, SINKS, WATER

AND GAS PIPING (CAP AND CLOSE AS REQUIRED), ELECTRICAL (IF APPLICABLE),

AND SHELVES. PREPARE EXISTING FLOOR AND WALL SURFACES TO REMAIN TO

RECEIVE NEW FINISHES.

8 REMOVE ALL FLOORING, BASES, AND ACCESSORIES, DOWN TO EXISTING CONC.

SLAB. CONTRACTOR TO VERIFY CONDITION OF EXISTING FLOOR SLAB AND PATCH

AND REPAIR IF NEEDED. PREPARE ALL DEMOLISHED AREAS TO RECEIVE NEW

FINISHES.SEE ID SHEETS/SPECS FOR DETAILS.

4 PREPARE EXISTING INTERIOR WALLS TO RECEIVE NEW FINISHES. NO ITEMS SHOULD

BE REMOVED FROM THE WALL. ALL WORK INCLUDING PAINT WORK SHOULD BE

DONE AROUND ALL EXISTING ELEMENTS ON THE WALL. PROTECT ELEMENTS AS

REQUIRED. PATCH & REPAIR AS REQUIRED.

9 REMOVE AND DISPOSE OF EXISTING FURNITURE, FIXTURES AND EQUIPMENT NOT

REMOVED BY THE OWNER.CONTRACTOR TO COORDINATE REQUIREMENTS FOR

DISPOSAL.

10 EXISTING SINKS TO BE REMOVED. PREPARE FOR NEW SINKS IN THE SAME

LOCATION.

12 REMOVE ALL FLOOR BASES. EXISTING FLOOR FINISH TO REMAIN. CLEAN AND

PREPARE TO RECEIVE NEW FINISH ON TOP OF EXISTING FLOOR FINISH (REFER TO

ENVIRONMENTAL REPORT)

13 EXISTING DOOR AND FRAME TO BE REMOVED. PATCH & REPAIR AS REQUIRED.

(SEE STRUCTURAL DWGS.)

11 REFER TO PLUMBING DRAWINGS FOR EXISTING PLUMBING FIXTURES AND UTILITY

LINES TO BE RELOCATED OR REMOVED. PROVIDE SLAB CUTS AS REQUIRED TO

CONNECT NEW SERVICES, WHERE NECESSARY. CONTRACTOR TO VERIFY EXISTING

LOCATIONS AND DEMOLISH ACCORDINGLY. PATCH AND REPAIR TO RECEIVE NEW

FINISHES.

14 EXISTING GLAZED WALL TILE IN CORRIDORS TO REMAIN. (PROTECT AS REQUIRED)

15 EXISTING MECHANICAL/ELECTRICAL ROOM.SEE MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS FOR SYSTEMS DEMOLITION REQUIREMENTS.

16 EXISTING STAGE TO BE PROTECTED AND PREPARED TO BE SANDED AND

RE-STAINED/VARNISHED. WALLS AND HANDRAIL TO BE PAINTED. (SEE FINISH

DWGS.) PROTECT ALL SYSTEMS, CURTAINS, ETC. AS REQUIRED.

EXISTING WALL

SCOPE BOUNDARY

ITEMS TO BE DEMOLISHED

17 EXISTING DRINKING FOUNTAIN TO REMAIN. (PROTECT AS REQUIRED.)

18 PREPARE WALL AS REQUIRED TO RECEIVE NEW FIRE ALARM PANEL (SEE FIRE

ALARM AND SYSTEM DRAWINGS.)

LEGEND

19 REMOVE EXISTING TEMPORARY WALL AND REPAIR / PREPARE TO LIKE NEW

CONDITION TO RECEIVE NEW FINISHES.

20 RELOCATE TEMPORARY (PHASING) DOOR ASSEMBLY AT CORRIDOR ALONG WITH

FRAMED AND FINISHED PARTITION TO SEPARATE SCOPE AREAS.

21 EXISTING FLOOR FINISH TO REMAIN. PAINT WALL AS REQUIRED - SEE FINISH PLANS.

(PROTECT AS REQUIRED)

22 REMOVE ALL EXISTING FLOORING, EXCEPT UNDER RACKS/UPS . CUT FLOORING

AROUND THE BASE OF THE RACKS AND UPS. REMOVE ALL EXISTING FLOORING,

EXCEPT UNDER RACKS/UPS . CUT FLOORING AROUND THE BASE OF THE RACKS

AND UPS. PROTECT TELECOM RACKS, UPS, AND CABLES/BUNDLES FROM

DUST/DEBRIS/PAINT DURING DEMOLITION AND RENOVATION .

DEMOLITION NOTES

1. DEMOLITION DRAWINGS ARE ONLY TO ASSIST IN SHOWING THE SCOPE OF

DEMOLITION WORK AND IT IS NOT INTENDED TO INDICATE ALL DEMOLITION.

CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE

WORK.

2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL

BE RESPONSIBLE FOR PERFORMING A WALK THROUGH OF THE PROJECT TO

IDENTIFY POSSIBLE CRITICAL ITEMS NOT OR INCORRECTLY ADDRESSED, WHICH

REQUIRE REMOVAL / RELOCATION PRIOR TO SUBMITTING A BID TO THE OWNER.

3. CONTRACTOR IS TO COORDINATE LOCATION OF ALL TEMPORARY DUST AND

PROTECTION BARRIERS TO MAINTAIN SAFE ACCESS TO EGRESS AT ALL TIMES.

CONSTRUCTION IAQ MANAGEMENT PLAN SHALL BE POSTED AT ALL TIMES.

4. CUT, REMOVE, PATCH, AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO

LEAVE WORK COMPLETE AND IN SATISFACTORY CONDITION.

5. CONTRACTOR IS TO PROTECT ALL CONCEALED UTILITIES. CONTRACTOR IS TO

INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES.

MECHANICAL AND / OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED.

6. RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE

IMMEDIATE SCOPE OF WORK IN VARIOUS AREAS WITHIN THE SCOPE. IT MAY REQUIRE

WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL, COMMUNICATIONS, DATA,

WATER, SEWER, FIRE SPRINKLER PROTECTION, ETC.). ANY WORK IN AREAS OUTSIDE

OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL-INCLUSIVE, PROVIDING ALL

UTILITIES, FINISHES AND EQUIPMENT REQUIRED TO RESTORE THE AREA TO FULLY

OPERATIONAL CONDITIONS.

7. CONTRACTOR IS TO PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY

DEMOLITION AND / OR INSTALLATION OF NEW MECHANICAL DUCT AND ELECTRICAL

CONDUITS ETC. AS REQUIRED, TO MATCH ADJACENT SURFACES AND / OR AS

REQUIRED FOR NEW SCHEDULED FINISHES.

8. FOR REMOVAL OF FIXTURES AND EQUIPMENT, REFER TO ARCHITECTURAL,

MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

9. REFER TO ELECTRICAL DRAWINGS FOR REMOVAL OF ANY ELECTRICAL PANELS,

OUTLETS, ETC.

10. ALL AREAS OF DEMOLITION OPERATIONS SHALL BE PROPERLY POSTED WITH SIGNS

WARNING OF DANGER. SUFFICIENT WATCH PERSONS SHALL BE PROVIDED TO WARN

WORKERS OF IMPENDING DANGERS, AND ALL UNAUTHORIZED PERSONS SHALL BE

EXCLUDED FROM PLACES WHERE DEMOLITION IS IN PROGRESS.

11. PROTECT ALL STRUCTURAL MEMBERS AS REQUIRED.

12. SCOPE OF REQUIRED SLAB CUTTING, REMOVAL AND REPAIR IS NOT INDICATED.

CONTRACTOR REQUIRED TO COORDINATE WILL ALL EXISTING AS-BUILT DRAWINGS

AND DESIGN DRAWINGS TO DETERMINE REQUIREMENTS FOR FULLY FUNCTIONING

SYSTEMS.

13. REMOVE ALL INTERIOR ROOM NAME SIGNAGE FOR NEW ROOM SIGNAGE TO BE

PROVIDED AND INSTALLED IN SCOPE OF RENOVATION WORK. SEE ID DWGS.

14. EXISTING GLAZED WALL TILE ON CORRIDORS TO REMAIN. PROTECT AS REQUIRED.

15. DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION PROTECT EXISTING

TELECOM RACKS, UPS, CABLES, CABLES/BUNDLES FROM DUST/DEBRIS/PAINT. ALL

DISTURBED, DAMAGED OR IMPARED CABLES AND OUTLETS SHALL BE PROVIDED NEW

CABLING AS REQUIRED AND TESTED TO CONFIRM LIKE NEW CONDITION AND

OPERATION. SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

D

C

B

A

C A

T E

G O

R Y

C O

D E

A N

S I D

E

F

G

2 3 4 5 6 7 8 9 10

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

JOSE L. MURGUIDO

Reg. AR0010670 June 2022

BIM 360://Maxwell Elementary Middle School SRM/1412_MEMS_SRM_ARCH CENTRAL_V18.rvt

8/11/2022 12:33:20 PM

J U

N E

W H

N B

A D

H

.d w g

-7

-0

AD401H

E N

L A

R G

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

A R

E A

H

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

-3

M a x w e ll

A ir F o rc e B a s e A la b a m a M a x w e ll

E le m e n ta ry M id d le

S c h o o l R e n o v a ti o n

F Y

RTA (READY TO ADVERTISE)

1/8" = 1'-0"AD401H

A4 ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA H

04 8 16268

SCALE: 1/8"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A U

G

DEMOLITION PLAN KEY NOTES

1 REMOVE EXISTING CONCRETE BLOCK WALL OR FRAMED WALL AND FINISH.

DEMOLISH FROM TOP OF EXISTING FLOOR SLAB INCLUDING TIE BEAM. PATCH &

REPAIR AS REQUIRED. (SEE STRUCTURAL DWGS.)

2 REMOVE EXISTING MECHANICAL UNIT AND ASSOCIATED COMPONENTS. PATCH AND

REPAIR AS REQUIRED . PREPARE EXISTING WALL SURFACES TO REMAIN TO

RECEIVE NEW FINSHES. (SEE MECHANICAL DRAWINGS)

3 REMOVE PORTIONS OR ALL OF EXISTING INTERIOR WALL PARTITIONS AS INDICATED

ON NEW FLOOR PLANS. PATCH & REPAIR AS REQUIRED TO MATCH EXISTING

ADJACENT CONDITIONS.

5 EXISTING CHILLERS. CONTRACTOR TO COORDINATE WITH REQUIRED PHASING AND

ENGINEERING REQUIREMENTS.

6 REMOVE EXISTING CEILINGS INCLUDING, BUT NOT LIMITED TO, ACOUSTIC CEILING

TILE GRIDS, SOFFITS, LIGHTING FIXTURES, MECHANICAL VENTS, AND CEILING

MOUNTED EQUIPMENTS. EXISTING SPRINKLER SYSTEM TO REMAIN, PROTECT AS

REQUIRED.

7 REMOVE EXISTING CASEWORK AND ASSOCIATED COMPONENTS INCLUDING, BUT

NOT LIMITED TO, BASE AND/OR UPPER CABINETS, COUNTERTOPS, SINKS, WATER

AND GAS PIPING (CAP AND CLOSE AS REQUIRED), ELECTRICAL (IF APPLICABLE),

AND SHELVES. PREPARE EXISTING FLOOR AND WALL SURFACES TO REMAIN TO

RECEIVE NEW FINISHES.

8 REMOVE ALL FLOORING, BASES, AND ACCESSORIES, DOWN TO EXISTING CONC.

SLAB. CONTRACTOR TO VERIFY CONDITION OF EXISTING FLOOR SLAB AND PATCH

AND REPAIR IF NEEDED. PREPARE ALL DEMOLISHED AREAS TO RECEIVE NEW

FINISHES.SEE ID SHEETS/SPECS FOR DETAILS.

4 PREPARE EXISTING INTERIOR WALLS TO RECEIVE NEW FINISHES. NO ITEMS SHOULD

BE REMOVED FROM THE WALL. ALL WORK INCLUDING PAINT WORK SHOULD BE

DONE AROUND ALL EXISTING ELEMENTS ON THE WALL. PROTECT ELEMENTS AS

REQUIRED. PATCH & REPAIR AS REQUIRED.

9 REMOVE AND DISPOSE OF EXISTING FURNITURE, FIXTURES AND EQUIPMENT NOT

REMOVED BY THE OWNER.CONTRACTOR TO COORDINATE REQUIREMENTS FOR

DISPOSAL.

10 EXISTING SINKS TO BE REMOVED. PREPARE FOR NEW SINKS IN THE SAME

LOCATION.

12 REMOVE ALL FLOOR BASES. EXISTING FLOOR FINISH TO REMAIN. CLEAN AND

PREPARE TO RECEIVE NEW FINISH ON TOP OF EXISTING FLOOR FINISH (REFER TO

ENVIRONMENTAL REPORT)

13 EXISTING DOOR AND FRAME TO BE REMOVED. PATCH & REPAIR AS REQUIRED.

(SEE STRUCTURAL DWGS.)

11 REFER TO PLUMBING DRAWINGS FOR EXISTING PLUMBING FIXTURES AND UTILITY

LINES TO BE RELOCATED OR REMOVED. PROVIDE SLAB CUTS AS REQUIRED TO

CONNECT NEW SERVICES, WHERE NECESSARY. CONTRACTOR TO VERIFY EXISTING

LOCATIONS AND DEMOLISH ACCORDINGLY. PATCH AND REPAIR TO RECEIVE NEW

FINISHES.

14 EXISTING GLAZED WALL TILE IN CORRIDORS TO REMAIN. (PROTECT AS REQUIRED)

15 EXISTING MECHANICAL/ELECTRICAL ROOM.SEE MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS FOR SYSTEMS DEMOLITION REQUIREMENTS.

16 EXISTING STAGE TO BE PROTECTED AND PREPARED TO BE SANDED AND

RE-STAINED/VARNISHED. WALLS AND HANDRAIL TO BE PAINTED. (SEE FINISH

DWGS.) PROTECT ALL SYSTEMS, CURTAINS, ETC. AS REQUIRED.

EXISTING WALL

SCOPE BOUNDARY

ITEMS TO BE DEMOLISHED

17 EXISTING DRINKING FOUNTAIN TO REMAIN. (PROTECT AS REQUIRED.)

18 PREPARE WALL AS REQUIRED TO RECEIVE NEW FIRE ALARM PANEL (SEE FIRE

ALARM AND SYSTEM DRAWINGS.)

LEGEND

19 REMOVE EXISTING TEMPORARY WALL AND REPAIR / PREPARE TO LIKE NEW

CONDITION TO RECEIVE NEW FINISHES.

20 RELOCATE TEMPORARY (PHASING) DOOR ASSEMBLY AT CORRIDOR ALONG WITH

FRAMED AND FINISHED PARTITION TO SEPARATE SCOPE AREAS.

21 EXISTING FLOOR FINISH TO REMAIN. PAINT WALL AS REQUIRED - SEE FINISH PLANS.

(PROTECT AS REQUIRED)

22 REMOVE ALL EXISTING FLOORING, EXCEPT UNDER RACKS/UPS . CUT FLOORING

AROUND THE BASE OF THE RACKS AND UPS. REMOVE ALL EXISTING FLOORING,

EXCEPT UNDER RACKS/UPS . CUT FLOORING AROUND THE BASE OF THE RACKS

AND UPS. PROTECT TELECOM RACKS, UPS, AND CABLES/BUNDLES FROM

DUST/DEBRIS/PAINT DURING DEMOLITION AND RENOVATION .

DEMOLITION NOTES

1. DEMOLITION DRAWINGS ARE ONLY TO ASSIST IN SHOWING THE SCOPE OF

DEMOLITION WORK AND IT IS NOT INTENDED TO INDICATE ALL DEMOLITION.

CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE

WORK.

2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL

BE RESPONSIBLE FOR PERFORMING A WALK THROUGH OF THE PROJECT TO

IDENTIFY POSSIBLE CRITICAL ITEMS NOT OR INCORRECTLY ADDRESSED, WHICH

REQUIRE REMOVAL / RELOCATION PRIOR TO SUBMITTING A BID TO THE OWNER.

3. CONTRACTOR IS TO COORDINATE LOCATION OF ALL TEMPORARY DUST AND

PROTECTION BARRIERS TO MAINTAIN SAFE ACCESS TO EGRESS AT ALL TIMES.

CONSTRUCTION IAQ MANAGEMENT PLAN SHALL BE POSTED AT ALL TIMES.

4. CUT, REMOVE, PATCH, AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO

LEAVE WORK COMPLETE AND IN SATISFACTORY CONDITION.

5. CONTRACTOR IS TO PROTECT ALL CONCEALED UTILITIES. CONTRACTOR IS TO

INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES.

MECHANICAL AND / OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED.

6. RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE

IMMEDIATE SCOPE OF WORK IN VARIOUS AREAS WITHIN THE SCOPE. IT MAY REQUIRE

WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL, COMMUNICATIONS, DATA,

WATER, SEWER, FIRE SPRINKLER PROTECTION, ETC.). ANY WORK IN AREAS OUTSIDE

OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL-INCLUSIVE, PROVIDING ALL

UTILITIES, FINISHES AND EQUIPMENT REQUIRED TO RESTORE THE AREA TO FULLY

OPERATIONAL CONDITIONS.

7. CONTRACTOR IS TO PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY

DEMOLITION AND / OR INSTALLATION OF NEW MECHANICAL DUCT AND ELECTRICAL

CONDUITS ETC. AS REQUIRED, TO MATCH ADJACENT SURFACES AND / OR AS

REQUIRED FOR NEW SCHEDULED FINISHES.

8. FOR REMOVAL OF FIXTURES AND EQUIPMENT, REFER TO ARCHITECTURAL,

MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.

9. REFER TO ELECTRICAL DRAWINGS FOR REMOVAL OF ANY ELECTRICAL PANELS,

OUTLETS, ETC.

10. ALL AREAS OF DEMOLITION OPERATIONS SHALL BE PROPERLY POSTED WITH SIGNS

WARNING OF DANGER. SUFFICIENT WATCH PERSONS SHALL BE PROVIDED TO WARN

WORKERS OF IMPENDING DANGERS, AND ALL UNAUTHORIZED PERSONS SHALL BE

EXCLUDED FROM PLACES WHERE DEMOLITION IS IN PROGRESS.

11. PROTECT ALL STRUCTURAL MEMBERS AS REQUIRED.

12. SCOPE OF REQUIRED SLAB CUTTING, REMOVAL AND REPAIR IS NOT INDICATED.

CONTRACTOR REQUIRED TO COORDINATE WILL ALL EXISTING AS-BUILT DRAWINGS

AND DESIGN DRAWINGS TO DETERMINE REQUIREMENTS FOR FULLY FUNCTIONING

SYSTEMS.

13. REMOVE ALL INTERIOR ROOM NAME SIGNAGE FOR NEW ROOM SIGNAGE TO BE

PROVIDED AND INSTALLED IN SCOPE OF RENOVATION WORK. SEE ID DWGS.

14. EXISTING GLAZED WALL TILE ON CORRIDORS TO REMAIN. PROTECT AS REQUIRED.

15. DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION PROTECT EXISTING

TELECOM RACKS, UPS, CABLES, CABLES/BUNDLES FROM DUST/DEBRIS/PAINT. ALL

DISTURBED, DAMAGED OR IMPARED CABLES AND OUTLETS SHALL BE PROVIDED NEW

CABLING AS REQUIRED AND TESTED TO CONFIRM LIKE NEW CONDITION AND

OPERATION.

PLAN NORTH

F

E

D

C

B

A

K

G H J

L

SRM

Renovation Bldg 538A

Zone 1

538B

538B1

538B2

538A Zone 2

538A.1

Zone 3

Zone 4

MUSIC

PE

BAND

OT/PT

CONFERENCE

ROOM

CLASSROOM

CLASSROOM

STORAGE

028C

STORAGE

028B

STORAGE

028A

CLASSROOM

CLOSET

030A

SERVICE

AREA

039F

CUSTODIAL

SERVICE

AREA

039E

CUSTODIAL

039D

STORAGE

OFFICE

D

Room F

OFFICE

G

OFFICE

E

OFFICE

C

OFFICE

B

TOILET

027D

TOILET

027F

STORAGE

027B

TOILET

027A

OFFICE

A

ADMIN

CORRIDOR

M109

STORAGE

035A

CLASSROOM

CLASSROOM

STORAGE

039A

RESTROOM

JANITOR

RESTROOM

CLASSROOM

6 8

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 124

6 84

6 124

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 84

6 124

6 84

6 124

6 84

6 84

6 84

6 84

6 84

TOILET

039C

TOILET

039B

1/ A

D

1H

1/ A

D

1J

1/AD401J

1/AD401K

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

S

C O

P E

B O

U N

D A

R Y

S C

O P

E B

O U

N D

A R

Y

A

E A

S T

S C

O P

E

O P

T

IO

N

A

S

C O

P E

O

P T

IO

N

538 B.1 SCOPE (FUTURE)

538 A.1 SCOPE (OPTION 1)

A6/ AD102

E1/ AD102

S C

O P

E B

O U

N D

A R

Y

S C

O P

E B

O U

N D

A R

Y

SCOPE BOUNDARY

4 6

6 124

6 124

6 124

SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

D

C

B

A

C A

T E

G O

R Y

C O

D E

A N

S I D

E

F

G

2 3 4 5 6 7 8 9 10

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

JOSE L. MURGUIDO

Reg. AR0010670 June 2022

BIM 360://Maxwell Elementary Middle School SRM/1412_MEMS_SRM_ARCH CENTRAL_V18.rvt

8/11/2022 12:41:54 PM

J U

N E

W H

N B

A D

J .d w g

-7

-0

AD401J

E N

L A

R G

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

A R

E A

J

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

-3

M a x w e ll

A ir F o rc e B a s e A la b a m a M a x w e ll

E le m e n ta ry M id d le

S c h o o l R e n o v a ti o n

F Y

RTA (READY TO ADVERTISE)

1/8" = 1'-0"AD401J

A5 ENLARGED FIRST FLOOR DEMOLITION PLAN - AREA J

04 8 16268

SCALE: 1/8"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A U

G

1 1

CR

S

P

PLAN NORTH

F

E

D

C

B

A

K

G H

J

L

SRM

Renovation Bldg 538A

Zone 1

538B

538B1

538B2

538A Zone 2

538A.1

Zone 3

Zone 4

RENOVATION AREA LEGEND

1 NEW DOOR AND FRAME ASSEMBLY. PROVIDE PROPER REINFORCEMENT AS

REQUIRED, PATCH & REPAIR ADJACENT SURFACES FOR A SMOOTH AND

COMPLETE ASSEMBLY. (SEE DOOR AND FRAME TYPE.)

2 EXISTING INTERIOR WALL PARTITIONS TO RECEIVE NEW PAINT FINISH. PATCH &

REPAIR AS REQUIRED TO MATCH EXISTING ADJACENT CONDITIONS.

3 NEW CEILING, SOFFITS, LIGHT FIXTURES, MECHANICAL VENTS / CONNECTIONS,

AND CEILING MOUNTED EQUIPMENT / FIXTURES. (SEE REFLECTED CEILING PLANS)

4 NEW CASEWORK AND ASSOCIATED COMPONENTS INCLUDING, BUT NOT LIMITED

TO, BASE AND/OR UPPER CABINETS, COUNTERTOPS, SINKS, WATER, SEWER AND

GAS PIPING, ELECTRICAL, AND SHELVING AS REQUIRED

5 NEW FLOORING AND BASEBOARDS. CONTRACTOR TO VERIFY CONDITION OF

EXISTING FLOOR SLAB AND PATCH AND REPAIR AS NEEDED FORE NEW FINISH

INSTALATION PER TO MEET MANUFACTURER'S REQUIREMENTS. SEE ID

SHEETS/SPECS FOR FINISH SELECTIONS.

7 EXISTING EXTERIOR WINDOW OR STOREFRONT / DOOR TO REMAIN. PROTECT AS

REQUIRED. PROVIDE REQUIRED BLOCKING AND SYSTEM CONNECTIONS AND NEW

ROLLER SHADE.

8 EXISTING DOOR, FRAME AND HARDWARE TO REMAIN. DOOR AND FRAME TO BE

REPAIRED, PATCHED, PREPED AND PAINTED AS REQUIRED. INSTALL NEW SHADE /

SCREEN DEVICE OVER GLAZED OPENING TO ALLOW FOR LOCKDOWN.

9 EXISTING ROOM FINISHES TO REMAIN. ALL EXISTING PAINTED SURFACES TO BE

REPAINTED. ALL SURFACES TO BE CLEANED. ALL FIXTURES TO BE MAINTAINED

AND CONFIRMED IN WORKING CONDITION..

10 EXISTING CASEWORK AND ASSOCIATED COMPONENTS AND FIXTURES TO REMAIN

INCLUDING, BUT NOT LIMITED TO, BASE AND/OR UPPER CABINETS,

COUNTERTOPS, SINKS, WATER, SEWER AND GAS PIPING, ELECTRICAL, AND

SHELVING. PROTECT AS REQUIRED

6 NEW INTERIOR WALL FINISH ASSEMBLY AT ALL WALLS IN THIS ROOM (SEE WALL

TYPE DESIGNATION)

11 PROVIDE NEW PRE-FINISHED INSULATED METAL PANEL OVER WATERPROOFING

MEMBRANE FOR WALL ASSEMBLY CLOSURE.

GENERAL NOTES

1. PENETRATIONS AND HOLES IN THE EXISTING FIRE WALLS SHALL BE PATCHED WITH

FIRE RATED TESTED ASSEMBLIES, SEALANT AND CLOSURE SYSTEMS IN

ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS.

2. ATTIC HEAT DETECTION ZONE IN PLAN ZONE D, E, AND F IS REQUIRED TO BE

ACTIVATED. PROVIDE NEW PANEL TO REPLACE REMOVED PANEL FROM PHASE 1

CONSTRUCTION FOR A FULLY OPERATIONAL SYSTEM. ALL EXISTING SYSTEMS AND

SAFETY TO LIFE SYSTEMS ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION

AND FOLLOWING FOR A COMPLETE OPERATIONAL FACILITY.

3. DURING CONSTRUCTION, CONTRACTOR IS TO ADVISE THE GOVERNMENT /

ARCHITECT / FIRE PROTECTION ENGINEER OF ANY RATED ASSEMBLIES OR SYSTEMS

THAT ARE DAMAGED / OR NOT CLOSED AS REQUIRED.

4. PROVIDE DOOR WINDOW LOCK DOWN SHADE FOR ALL DOOR GLAZING (ATTACHED

TO DOOR) LOCATIONS IN THE SCOPE OF WORK AREA (REGARDLESS OF WORK OR

REPLACEMENT). SYSTEM SHALL BE FIRE RETARDENT MATERIAL WITH BLACKOUT

FABRIC, WEIGHTED HEM BAR AND VELCRO HOLD STRAP (BLACK) AND SHALL BE

SIZED FOR FULL GLAZING COVERAGE.

5. PROVIDE AND INSTALL NEW ROLLER SHADE (MANUAL) AT ALL FIXED INTERIOR AND

EXTERIOR WINDOWS AND GLAZED AREAS WITHIN THE FULL SCOPE OF WORK.

6. ALL EXISTING DOORS TO REMAIN ARE TO RETAIN ALL EXISTING OPERATION AND

HARDWARE IN ACCORDANCE WITH THE EXISTING COSNTRUCTION AND RATING

SYSTEM.

7. ALL OLD SKYLIGHT CAPS ARE TO BE REPLACED WITH INSULATED DOUBLE WALL

METAL WRAPPED ASSEMBLIES TO ENSURE THERMAL CLOSURE. COORDIANTE ALL

LOCATIONS WITH REQUIRED MECAHNICAL PENETRATIONS AND ACCOMODATE

CLOSURE IN ACCRDANCE WITH MECHANICAL REQUIREMENTS (SEE MECHANICALAND

SYSTEMS DRAWINGS FOR COORDIANTION).

8. EXTERIOR WALL ASSMEBLY CLOSURE TO ENSURE VAPOR / MOISTURE SEPARATION

AND CLOSURE OF THE EXTERIOR ENVELOPE.INFIULL MASONRY AND BRICK TO

MATCH INSTALLATION AND FINISH OF THE ADJACENT SIMILAR ASSEMBLY. PARTIAL

REMOVAL OF EXTERIOR FACING BRICK MAY BE NEEDED TO ENSURE

WATERPROOFING SYSTEM CONTINUITY AND CKOSURE. REPAIR AS REQUIRED.

9. PROVIDE TRANSITION REDUCER ADAPTER PER MANUFACTURER'S

RECOMMENDATION AT ALL CHANGES OF FLOOR ELEVATION.

10. AT ALL AREAS WHERE VCT IS TO REMAIN FLOOR FINISH IS TO BE STRIPPED AND

WAXED IN ACCORDANCE WITH INDUSTRY STANDARDS. (MIN 3 COATS)

12 STAGE FLOOR TO BE SANDED AND RE-STAINED/VARNISHED. WALLS AND

HANDRAIL TO BE PAINTED. SEE FINISH PLANS.

13 PREPARE WALL AREA AS REQUIRED FOR NEW ACCENT WALL FINISH AND

SIGNAGE. (SEE FINISH PLANS AND INTEROR ELEVATIONS.)

14 PROTECT TEMPORARY RELOCATED CORRIDOR WALL AND DOOR ASSEMBY AS

REQUIRED FOR SEPARATION OF BASE AND OPTION AREA SCOPES OF WORK.

ALLOW FOR EXITING AT ALL TIMES.

15 CONTINUE EXISTING CORRIDOR WALL RATING (SMOKE PARITION) AND CLOSE

EXISTING AND NEW PARTITIONS TO UNDERSIDE OF STRUCTURAL DECK.

16 EXISTING EXTERIOR DOOR ASSEMBLY TO REMAIN. (ADAPT AS REQUIRED TO

ACCOMODATE NEW ACCESS CONTROL SYSTEM AND HARDWARE.)

17 NEW SINKS. REFER TO PLUMBING DRAWINGS

18 NEW FLOORING, EXCEPT UNDER RACKS/UPS . HAND PAINTING ONLY BY ROLLER

OR BRUSH (NO SPRAY PAINTING IN THAT ROOM). PROTECT TELECOM RACKS,

UPS, AND CABLES/BUNDLES FROM DUST/DEBRIS/PAINT DURING DEMOLITION AND

RENOVATION

CORRIDOR

1F05

SUPPLY

ROOM

CURRICULUM

MATERIALS

ROOM

MECH.

ROOM

010A

CLASSROOM

CLASSROOM

VESTIBULE

V006

TOILET

008A

TOILET

006A

CLASSROOM

VESTIBULE

V002

TOILET

004A

TOILET

002A

CLASSROOM

CLASSROOM

VESTIBULE

V001

TOILET

001A

TOILET

003A

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

OFFICE

011A

WORKSPACE

ADA

RESTROOM

RESTROOM

015D

WORK/

COPY

015C

STAFF

WORKROOM

/ LOUNGE

TOILET

015B

OFFICE

015A

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

3 6

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

1/ A

E

1G

1/ A

E

1H

SCOPE BOUNDARY

SCOPE BOUNDARY

S C

O P

E B

O U

N D

A R

Y

CORRIDOR

1G12

CORRIDOR

1G12

2 3 5

VESTIBULE

013A

C6.2

H3.3

H2.3

H2.3

A6.1

3'-0"

3'-0"

C6.5

8'-6 1/2"

3'-0" 7

A3

AE601

/C3 AE601

1G12

S C

O P

E B

O U

N D

A R

Y

HE2.5

HE2.5

S C

O P

E B

O U

N D

A R

Y

EXISTING WALL

SCOPE BOUNDARY

NEW INTERIOR PARTITION

538 A - WEST SCOPE (BASE BID)

538 A - EAST SCOPE & 538 A.1 SCOPE - (OPTION 1)

LEGEND

SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

D

C

B

A

C A

T E

G O

R Y

C O

D E

A N

S I D

E

F

G

2 3 4 5 6 7 8 9 10

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

Z Y

S C

O V

IC

H

IN

C

JOSE L. MURGUIDO

Reg. AR0010670 June 2022

BIM 360://Maxwell Elementary Middle School SRM/1412_MEMS_SRM_ARCH CENTRAL_V18.rvt

8/11/2022 12:33:29 PM

J U

N E

W H

N B

A E

G

.d w g

-7

-0

AE401G

E N

L A

R G

E D

F

IR

S T

F L O

O R

P L A

N

A R

E A

G

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

-3

M a x w e ll

A ir F o rc e B a s e A la b a m a M a x w e ll

E le m e n ta ry M id d le

S c h o o l R e n o v a ti o n

F Y

RTA (READY TO ADVERTISE)

04 8 16268

SCALE: 1/8"=1'-0"

1/8" = 1'-0"AE401G

A6 ENLARGED FIRST FLOOR PLAN - AREA G

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A U

G

ES

P

ES

P

CR

PLAN NORTH

F

E

D

C

B

A

K

G H J

L

SRM

Renovation Bldg 538A

Zone 1

538B

538B1

538B2

538A Zone 2

538A.1

Zone 3

Zone 4

RENOVATION AREA LEGEND

1 NEW DOOR AND FRAME ASSEMBLY. PROVIDE PROPER REINFORCEMENT AS

REQUIRED, PATCH & REPAIR ADJACENT SURFACES FOR A SMOOTH AND

COMPLETE ASSEMBLY. (SEE DOOR AND FRAME TYPE.)

2 EXISTING INTERIOR WALL PARTITIONS TO RECEIVE NEW PAINT FINISH. PATCH &

REPAIR AS REQUIRED TO MATCH EXISTING ADJACENT CONDITIONS.

3 NEW CEILING, SOFFITS, LIGHT FIXTURES, MECHANICAL VENTS / CONNECTIONS,

AND CEILING MOUNTED EQUIPMENT / FIXTURES. (SEE REFLECTED CEILING PLANS)

4 NEW CASEWORK AND ASSOCIATED COMPONENTS INCLUDING, BUT NOT LIMITED

TO, BASE AND/OR UPPER CABINETS, COUNTERTOPS, SINKS, WATER, SEWER AND

GAS PIPING, ELECTRICAL, AND SHELVING AS REQUIRED

5 NEW FLOORING AND BASEBOARDS. CONTRACTOR TO VERIFY CONDITION OF

EXISTING FLOOR SLAB AND PATCH AND REPAIR AS NEEDED FORE NEW FINISH

INSTALATION PER TO MEET MANUFACTURER'S REQUIREMENTS. SEE ID

SHEETS/SPECS FOR FINISH SELECTIONS.

7 EXISTING EXTERIOR WINDOW OR STOREFRONT / DOOR TO REMAIN. PROTECT AS

REQUIRED. PROVIDE REQUIRED BLOCKING AND SYSTEM CONNECTIONS AND NEW

ROLLER SHADE.

8 EXISTING DOOR, FRAME AND HARDWARE TO REMAIN. DOOR AND FRAME TO BE

REPAIRED, PATCHED, PREPED AND PAINTED AS REQUIRED. INSTALL NEW SHADE /

SCREEN DEVICE OVER GLAZED OPENING TO ALLOW FOR LOCKDOWN.

9 EXISTING ROOM FINISHES TO REMAIN. ALL EXISTING PAINTED SURFACES TO BE

REPAINTED. ALL SURFACES TO BE CLEANED. ALL FIXTURES TO BE MAINTAINED

AND CONFIRMED IN WORKING CONDITION..

10 EXISTING CASEWORK AND ASSOCIATED COMPONENTS AND FIXTURES TO REMAIN

INCLUDING, BUT NOT LIMITED TO, BASE AND/OR UPPER CABINETS,

COUNTERTOPS, SINKS, WATER, SEWER AND GAS PIPING, ELECTRICAL, AND

SHELVING. PROTECT AS REQUIRED

6 NEW INTERIOR WALL FINISH ASSEMBLY AT ALL WALLS IN THIS ROOM (SEE WALL

TYPE DESIGNATION)

11 PROVIDE NEW PRE-FINISHED INSULATED METAL PANEL OVER WATERPROOFING

MEMBRANE FOR WALL ASSEMBLY CLOSURE.

GENERAL NOTES

1. PENETRATIONS AND HOLES IN THE EXISTING FIRE WALLS SHALL BE PATCHED WITH

FIRE RATED TESTED ASSEMBLIES, SEALANT AND CLOSURE SYSTEMS IN

ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS.

2. ATTIC HEAT DETECTION ZONE IN PLAN ZONE D, E, AND F IS REQUIRED TO BE

ACTIVATED. PROVIDE NEW PANEL TO REPLACE REMOVED PANEL FROM PHASE 1

CONSTRUCTION FOR A FULLY OPERATIONAL SYSTEM. ALL EXISTING SYSTEMS AND

SAFETY TO LIFE SYSTEMS ARE TO REMAIN OPERATIONAL DURING CONSTRUCTION

AND FOLLOWING FOR A COMPLETE OPERATIONAL FACILITY.

3. DURING CONSTRUCTION, CONTRACTOR IS TO ADVISE THE GOVERNMENT /

ARCHITECT / FIRE PROTECTION ENGINEER OF ANY RATED ASSEMBLIES OR SYSTEMS

THAT ARE DAMAGED / OR NOT CLOSED AS REQUIRED.

4. PROVIDE DOOR WINDOW LOCK DOWN SHADE FOR ALL DOOR GLAZING (ATTACHED

TO DOOR) LOCATIONS IN THE SCOPE OF WORK AREA (REGARDLESS OF WORK OR

REPLACEMENT). SYSTEM SHALL BE FIRE RETARDENT MATERIAL WITH BLACKOUT

FABRIC, WEIGHTED HEM BAR AND VELCRO HOLD STRAP (BLACK) AND SHALL BE

SIZED FOR FULL GLAZING COVERAGE.

5. PROVIDE AND INSTALL NEW ROLLER SHADE (MANUAL) AT ALL FIXED INTERIOR AND

EXTERIOR WINDOWS AND GLAZED AREAS WITHIN THE FULL SCOPE OF WORK.

6. ALL EXISTING DOORS TO REMAIN ARE TO RETAIN ALL EXISTING OPERATION AND

HARDWARE IN ACCORDANCE WITH THE EXISTING COSNTRUCTION AND RATING

SYSTEM.

7. ALL OLD SKYLIGHT CAPS ARE TO BE REPLACED WITH INSULATED DOUBLE WALL

METAL WRAPPED ASSEMBLIES TO ENSURE THERMAL CLOSURE. COORDIANTE ALL

LOCATIONS WITH REQUIRED MECAHNICAL PENETRATIONS AND ACCOMODATE

CLOSURE IN ACCRDANCE WITH MECHANICAL REQUIREMENTS (SEE MECHANICALAND

SYSTEMS DRAWINGS FOR COORDIANTION).

8. EXTERIOR WALL ASSMEBLY CLOSURE TO ENSURE VAPOR / MOISTURE SEPARATION

AND CLOSURE OF THE EXTERIOR ENVELOPE.INFIULL MASONRY AND BRICK TO

MATCH INSTALLATION AND FINISH OF THE ADJACENT SIMILAR ASSEMBLY. PARTIAL

REMOVAL OF EXTERIOR FACING BRICK MAY BE NEEDED TO ENSURE

WATERPROOFING SYSTEM CONTINUITY AND CKOSURE. REPAIR AS REQUIRED.

9. PROVIDE TRANSITION REDUCER ADAPTER PER MANUFACTURER'S

RECOMMENDATION AT ALL CHANGES OF FLOOR ELEVATION.

10. AT ALL AREAS WHERE VCT IS TO REMAIN FLOOR FINISH IS TO BE STRIPPED AND

WAXED IN ACCORDANCE WITH INDUSTRY STANDARDS. (MIN 3 COATS)

12 STAGE FLOOR TO BE SANDED AND RE-STAINED/VARNISHED. WALLS AND

HANDRAIL TO BE PAINTED. SEE FINISH PLANS.

13 PREPARE WALL AREA AS REQUIRED FOR NEW ACCENT WALL FINISH AND

SIGNAGE. (SEE FINISH PLANS AND INTEROR ELEVATIONS.)

14 PROTECT TEMPORARY RELOCATED CORRIDOR WALL AND DOOR ASSEMBY AS

REQUIRED FOR SEPARATION OF BASE AND OPTION AREA SCOPES OF WORK.

ALLOW FOR EXITING AT ALL TIMES.

15 CONTINUE EXISTING CORRIDOR WALL RATING (SMOKE PARITION) AND CLOSE

EXISTING AND NEW PARTITIONS TO UNDERSIDE OF STRUCTURAL DECK.

16 EXISTING EXTERIOR DOOR ASSEMBLY TO REMAIN. (ADAPT AS REQUIRED TO

ACCOMODATE NEW ACCESS CONTROL SYSTEM AND HARDWARE.)

17 NEW SINKS. REFER TO PLUMBING DRAWINGS

18 NEW FLOORING, EXCEPT UNDER RACKS/UPS . HAND PAINTING ONLY BY ROLLER

OR BRUSH (NO SPRAY PAINTING IN THAT ROOM). PROTECT TELECOM RACKS,

UPS, AND CABLES/BUNDLES FROM DUST/DEBRIS/PAINT DURING DEMOLITION AND

RENOVATION

CORRIDOR

1G12

STAFF

WORKROOM

/ LOUNGE

MULTI-PURPOSE

MECHANICAL

ROOM

M16

JANITOR

J016

RESTROOM

016A

RESTROOM

016B

STORAGE

SERVER

ROOM

017A

OFFICE

017B

CLASSROOM

TEACHER'S

WORK

ROOM

CLASSROOM

CLASSROOM

2 3 5

2 3 5

2 3 5

2 3 5

2 3 5

8 8 8

2 3 5

2 3 5

2 3 5

2 3 5

1/ A

E

1G

1/ A

E

1H

1/ A

E

1H

1/ A

E

1J

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

SCOPE BOUNDARY

A

E A

S T

S C

O

A

W E

S T

S C

O

STAGE

014A

2 3 5

CORRIDOR

1G12

2 3 5

1G

A

1G 12B

13 1313

17 17

A3

AE601

S C

O P

E B

O U

N D

A R

Y

SCOPE BOUNDARY

EXISTING WALL

SCOPE BOUNDARY

NEW INTERIOR PARTITION

538 A - WEST SCOPE (BASE BID)

538 A - EAST SCOPE & 538 A.1 SCOPE - (OPTION 1)

LEGEND

SHEET ID

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .