B.08 - Solicitation - W912HN22B4003 - Drawings-Volume 2-AMD 2.pdf
PDF 14 MB Posted
- Solicitation number
- W912HN22B4003
About this file
This document summarizes a draft solicitation for Project Number 101083 to repair the HVAC systems in Buildings 3405 and 3425 at Fort Benning, Georgia. The U.S. Army Corps of Engineers Savannah District will issue a firm-fixed-price invitation for bid under NAICS code 238220 for plumbing, heating, and air conditioning contractors. The estimated value is between $10-25 million. The scope of work involves repairing and replacing HVAC equipment, controls, ductwork, and piping to improve conditions in sleeping, classroom, and office areas. The closing date for bids is September 12, 2022, and the period of performance is 840 calendar days from notice to proceed. The solicitation documents are available on SAM.gov, and bids must be submitted electronically through PIEE. Interested parties should monitor the website for amendments and contact the named contracting staff with any questions.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7 5/8", 11 5/8"
/8
SECTION
(2) #5
SPAN
ELEVATION
8" (MIN. BRG.)
LINTEL ML1
LINTEL
DESIGNATION
ML1
ML2
LINTEL TYPE
(NOMINAL DIMENSION)
8" HIGH CMU LINTEL
MASONRY OPENING
MAX. SPAN (FT) UNLESS
NOTED OTHERWISE
MINIMUM END
BEARING (INCHES)
84'-0"
MASONRY LINTEL SCHEDULE
LINTEL NOTES:
1. UNLESS OTHERWISE SHOWN, SELECT LINTEL TO SUIT INDICATED MASONRY OPENING AT OR
BELOW MAXIMUM ALLOWABLE SPAN INDICATED. LINTEL TYPE IS AT CONTRACTORS OPTION
EXCEPT AS NOTED OR DETAILED.
2. PROVIDE LINTELS @ ALL NEW PENETRATIONS OF INTERIOR MASONRY WALLS. COORDINATE
SIZE & LOCATION OF OPENINGS WITH APPROPRIATE TRADE.
3. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR OPENING SIZES.
4. MASONRY USED FOR LINTELS SHALL MATCH THAT OF THE ADJACENT WALL.
LOOSE STEEL ANGLE LINTEL SCHEDULE
LINTEL
DESIGNATION STEEL ANGLE SIZE
MASONRY OPENING
MAXIMUM SPAN (FT)
MINIMUM END
BEARING (INCHES)
SL1 L3 1/2 x 3 1/2 x 1/4 5'-0 4
LINTEL NOTES:
1. ALL LINTELS EXPOSED TO EXTERIOR SHALL BE HOT-DIPPED GALVANIZED.
2. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR OPENING SIZES.
8" HIGH PRECAST 6'-0" 8
SECTION
(2) #5, TOP
LINTEL ML2
/8
7 5/8"
(2) #5, BOT.
#3 TIES @ 6"oc
CLR.
3/4"
SIZE = 2' - 0" x 2' - 0"
EXIST. OPNG. (DIMS.
V.I.F., MAX OPNG.
EXIST. ELEV.
CONC. SLAB &
DECK (4" TOTAL
THK.)
EXIST. BEAM -
TO REMAIN)EXIST. BEAM -
TO REMAIN)
EXIST. ELEV. CONC.
SLAB & DECK (4"
TOTAL THK.)
NEW L4x4x3/8, (2)
SIDES OF OPNG.
(V.I.F. OPNG. DIMS.
FOR LENGTHS OF
L4x4
NEW 2 1/2" CONC.
(LW) & 1 1/2" DECK (20
GA.). NEW DECK
PROFILE SHALL
MATCH EXIST. DECK
PROFILE (V.I.F.)
(2) 3/8" DIA. EPOXY ANCHORS
BETWEEN VERT. LEG OF L4x4
& EXIST. SLAB. EMBED. &
EPOXY 2 1/2" INTO EXIST. CONC.
CENTER ANCHOR IN WIDTH
OF 4" THK. FLUTE LOCATIONS.
PROVIDE 12" BETWEEN
ANCHORS (EA. SIDE)
NEW CONC. FINISH
SHALL MATCH
EXIST. CONC.
ADJACENT TO INFILL
ROOF LOAD
HANGAR
HANGER
NOTE:
IN NO CASE SHALL THE LOAD EXCEED THE
LOAD ENVELOPE CREATED BY THE STATED
COLLATERAL LOADS.
1/8"
TYP
FIELD WELD 2 ANGLES FROM TOP
OR BOTTOM CHORD PANEL POINT
TO CONCENTRATED LOAD
LOCATION. (ONE ANGLE EA SIDE
OF JOIST CHORDS) MIN. REQ'D
ANGLE SIZES ARE AS FOLLOWS
JOIST DEPTH
8" TO 24"
26" TO 48"
52" TO 72"
ANGLE SIZE
L1-1/2x1-1/2x3/16 L2x2x3/16 L3x3x1/4
MODIFICATION IS TYP FOR ALL JOISTS
SUPPORTING LOAD FROM TOP OR
BOTTOM CHORD BETWEEN PANEL PTS
VERIFY LOC & NO OF LOADS W/ ARCH,
MECH, PLUMB, & ELEC DWGS. ANGLES
NOT REQ'D FOR CONCENTRATED LOADS
LESS THAN 100 LBS.
NOTE:
TOUCH UP FIELD WELDS W/ PAINT AS REQ'D
TO MATCH SHOP PRIMER.EXIST. SUPPORT BEAM
CUT & REMOVE DECK
WITHIN OPENING AFTER
FRAMING IS COMPLETED
COPED ENDS FOR
ANGLES (TYP)
CHANNEL C8x11.5 OR ANGLE FRAME L6x3 1/2x5/16
(LLV) TURNED DOWN TO
FORM PERIMETER OF
OPNG.
SLAB OPNG. COORD.
SIZE & LOCATION w/
APPLICABLE TRADE
CONTRACTOR
2"
ANGLE
BEARING
CHANNEL
CONNECTION
CL
SUPPORT
D E
C K
S P
A N
NOTES:
USE L6x3 1/2x5/16 WHEN OPNG SIZE EXCEEDS 1'-6" AND IS LESS THAN 3'-8". USE C8x11.7 WHEN OPNG IS BETWEEN 3'-8" AND 12'-0".
3/4"
EXIST. SUPPORT BEAM
EXIST. ROOF JOIST OR BEAM
(JOIST AS SHOWN). COORD.
SIZE, SPA., & SPAN DIR. IN
FIELD. AT JOIST LOCATIONS,
REFER TO C5/S-501 FOR NEW
WEB REINF. REQUIREMENT
WITHIN JOIST AT L4x4 SUPPORT
ANGLES (BETWEEN JOISTS)
EXIST. ROOF DECK.
- TO REMAIN (ROOF MAT'L
ABOVE DECK NOT SHOWN
FOR CLARITY, V.I.F.)
EXIST MECH. EQUIP. CURB - TO
REMAIN. CONTRACTOR TO
REMOVE METAL COPING ALONG
LENGTH OF CURB AND VERIFY
CONDITION AND CONSTRUCTION
OF CURB (ASSUMED WOOD 2x).
NOTIFY EOR IF ROT IS
OCCURRING OR CONSTRUCTION
TYPE DIFFERS PRIOR TO
SUPPORT INSTALL.
NEW L4x4x5/16x6" LG (GALV) @ EA. POST LOCATION w/ (3)
1/4" DIAMETER LAG SCREWS
(SS) BETWEEN L4x4 & EXIST 2x. EMBED SCREWS 2 1/2"
(MIN.) INTO EXIST. 2X.
COORD. SPA. w/ MECH EQUIP.
MECH. EQUIP. RAILS. COORD.
w/ MANUF. FOR SIZE & CONN.
TO SUPPORT FRAME
HSS3x0.250 POST (GALV.)
w/ 1/2" CAP PL. CENTER
ON CURB (WIDTH) BELOW
& C8 FRAME (ABOVE)
C8x11.5 MECH. EQUIP. SUPPORT
FRAME (GALV.). CENTER ON
EQUIP RAILS. COORD. PLAN
& RAIL DIMS. w/ MECH EQUIP.
3/16
POST TO
L4x4 (TYP.)
3/16
C8 TO
1/2" CAP PL
3/16
C8 FLANGE
TO C8
FLANGE,
TOP & BOT.
(M
A X
B
O T
S
T L
T O
T /E
X
IS
T C
U R
B
EXIST. STEEL ANGLE FRAME
(BETWEEN JOISTS/BEAMS)
BELOW EXIST. CURB LOCATIONS.
CONTRACTOR SHALL FIELD
VERIFY EXIST. ANGLE LOCATION
& SIZE. IF ANGLE FRAME
PRESENT, NOTIFY EOR WITH SIZE
OF ANGLES FOR SUPPORT
VERIFY. IF EXIST. ANGLE NOT
PRESENT, PROVIDE NEW L4x4x3/8
SUPPORT ANGLES. CENTER
BELOW CURB & SPAN BETWEEN
EXIST. JOISTS/BEAMS
VARIES, V.I.F.VARIES, V.I.F.
EQUIPMENT LOCATION (ROOM)
MAXIMUM
WEIGHT (lbs)
ERV ROOF 1500
AHU
(MECHANICAL ROOM @ EA.
BUNK AREA - 217A, 317A)
AHU (H-1)
(MECHANICAL ROOM -
A219, E219)
ERV (H-1) (MECHANICAL ROOM -
A219, E219)
NOTE: COORDINATE WITH MECHANICAL SHEETS M-601 AND
M-602 FOR ACTUAL EQUIPMENT WEIGHTS (PER PROVIDED
EQUIPMENT CUT SHEETS)
EXIST. ROOF JOIST
OR BEAM - TO
REMAIN (JOIST AS
SHOWN). COORD.
SUPPORT CONDITION
IN FIELD.
NEW L4x4x1/4
FRAME AROUND
NEW OPNG.
3/16
WELD TO
STRUCTURAL
SUPPORT
DWGS. FOR DIMS
NEW ROOF PENETRATION
REFER TO MECH.
EXIST. ROOF DECK
TO REMAIN. COORD.
w/ ARCH. DWGS. ON
REMOVAL EXTENTS
AROUND NEW OPNG.
EXIST. ROOF DECK
TO REMAIN. COORD.
w/ ARCH. DWGS. ON
REMOVAL EXTENTS
AROUND NEW OPNG.
NOTE:
1. CONNECTIONS SHALL BE SHOP
AND/OR FIELD WELDED
2. COORDINATE OPENING SIZE AND
LOCATION w/ ARCHITECTURAL &
MECHANICAL DRAWINGS.
3. NEW DECK INFILL SHALL LAP
EXISTING DECK (TO REMAIN) - 6" (MIN.)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
S-501
S T
R U
C T
U R
A L
D E
T A
IL
S
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
S R
IC
C
I
S R
IC
C
I
A H
A U
T M
A N
S S
A P
S F
O R
D
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
SCALE: 1" = 1'-0"
D1
LINTEL DETAILS AND SCHEDULES
SCALE: 3/4" = 1'-0"
F5
FLOOR FRAMING - EXISTING SLAB INFILL (NO EXISTING
SUPPORT FRAME, 24"x24" (MAX.) EXISTING OPENING)
SCALE: 1" = 1'-0"
C5
JOIST MODIFICATION AT CONCENTRATED LOADS
SCALE: 1" = 1'-0"
A1
CHANNEL OR ANGLE FRAMED SLAB OPENING
SCALE: 3/4" = 1'-0"
A5
MECHANICAL EQUIPMENT SUPPORT DETAIL (AT EXISTING
CURB)
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
SCALE: 1" = 1'-0"
F8
MAXIMUM EQUIPMENT WEIGHT (MAXIMUM)
SCALE: 1" = 1'-0"
C8
NEW ROOF PENETRATION FRAMING DETAILS
13 13
14 14
15 15
16 16
19 19
22 22
23 23
24 24
26 26
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
Px.L
Px.L
U.L
U.L
W.L
W.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
U.R
U.R
W.R
W.R
Px.R
Px.R
S.R
S.R
/MATCHLINE - A1 AD126 /MATCHLINE - A1 AD126
/MATCHLINE - A1 AD115 /MATCHLINE - A1 AD122
/MATCHLINE - A1 AD123/MATCHLINE - A1 AD114
/MATCHLINE - A1 AD124
OPEN AIR
HALLWAY
4 4
2' - 7" +/-
2' - 7" +/-
2' - 7" +/-
2' - 7" +/-
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR GENERAL DEMOLITION NOTES.
B. ALL FINISHES ARE EXISTING TO REMAIN UNO
C. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
DEMOLITION LEGEND
EXISTING TO REMAIN
WORK TO BE REMOVED
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
AD125
R O
O F
D E
M O
L
IT
IO
N
P L
A N
A
R E
A G
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
ROOF DEMOLITION PLAN - AREA G
1 EXISTING LOUVER TO BE REMOVED.
2 EXISTING TPO ROOF MEMBRANE OVER RIGID INSULATION TO REMAIN. PATCH
AND REPAIR ROOF SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS AT REQUIRED LOCATIONS AFTER REMOVAL OF EXISTING
ROOF TOP MECHANICAL EQUIPMENT AND ASSOCIATED PIPING OR CONDUIT, AS
WELL AS LOCATIONS OF DAMAGE DURING CONSTRUCTION. PROVIDE RIGID
INSULATION INFILL TO MATCH EXISTING AS REQUIRED. CONTRACTOR IS TO
PROTECT MEMBRANE THROUGHOUT CONSTRUCTION FROM DAMAGE.
3 EXISTING MECHANICAL EQUIPMENT CURB TO REMAIN. CONTRACTOR TO
REMOVE METAL COPING ALONG LENGTH OF CURB AND VERIFY CONDITION AND
CONSTRUCTION OF CURB (ASSUMED WOOD 2x). NOTIFY CONTRACTING
OFFICER IF ROT IS OCCURRING OR CONSTRUCTION TYPE DIFFERS PRIOR TO
SUPPORT INSTALL.
4 AREA OF EXISTING TPO MEMBRANE ROOFING SYSTEM AND METAL DECKING TO
BE REMOVED FOR NEW EQUIPMENT ROOF PENETRATION. COORDIANTE
LOCATION TO AVOID MAJOR STRUCTURAL ELEMENTS. COORDINATE SIZE OF
OPENING WITH NEW CURB REQUIREMENTS (REFER 'M' DRAWINGS) AND
REQUIREMENTS FOR NEW OPENING REINFORCEMENT (REFER C8/S-501).
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
09/14/2022
EXP: 12/31/2023
12 12
13 13
14 14
15 15
16 16
17 17
19 19
21x 21x
22 22
23 23
24 24
25 25
26 26
M.L
M.L
Px.L
Px.L
U.L
U.L
V.L
V.L
W.L
W.L
X.L
X.L
Y.L
Y.L
Z.L
Z.L
AA.L
AA.L
CC.L
CC.L
DD.L
DD.L
EE.L
EE.L
FF.L
FF.L
S.L
S.L
17' - 10" 90' - 3" 19' - 5"
127' - 6"
STAIR #5
A106
LUGGAGE
A105A
LAUNDRY
A105
MECHANICAL
A104
STORAGE
A112
RECEPTION
A113
CORRIDOR
A114
MEN
A115
WOMEN
A116
CQ
A117
C O
R R
ID
O
R
A
1ST SGT
A119
CO OPS
COMMANDER
A120
STORAGE
A121
VESTIBULE
G101
OPS SGT
A123
CORRIDOR
G104
CORRIDOR
G105
CORRIDOR
G106
WOMEN
H102
STORAGE
H122
21 21
CORRIDOR
A122
1/MATCHLINE - A1 AD150
/MATCHLINE - A1 AD152
/MATCHLINE - A1 AD161
/MATCHLINE - A1 AD162
/MATCHLINE - A1 AD150
3' - 11"
7' - 6"
MEN
B115
WOMEN
B116
CORRIDOR
G102
OUTDOOR TRAINING AREA
4' - 5"
MEN
G108
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR GENERAL DEMOLITION NOTES.
B. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
C. REFER TO ELECTRICAL ('E' SERIES SHEETS) FOR INFORMATION REGARDING
REMOVAL AND SALVAGE OF AFFECTED DEVICES.
D. REFER TO FIRE PROTECTION ('F' SERIES SHEETS) FOR INFORMATION
REGARDING REMOVAL AND SALVAGE OF AFFECTED CEILING MOUNTED
DEVICES.
E. ALL FINISHES ARE EXISTING TO REMAIN UNO
F. DIMENSIONS SHOW AT GYPSUM BOARD DEMOLITION ARE ASSUMED EXTENTS
OF CEILING TO BE REMOVED TO COMPLETE WORK. CONTRACTOR TO REMOVE
GYPSUM CEILING AS NECESSARY TO COMPLETE WORK.
G. UNO, REMOVE AND SALVAGE FOR POSSIBLE RE-USE EXISTING SUSPENEDED
ACOUSTICAL CEILING TILE AND GRID AS REQUIRED TO PERFORM HVAC WORK
ABOVE. REMOVE TO NEAREST FULL TILE. WATER DAMAGED CEILING TILE AT
EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS ARE TO BE DISCARDED.
COORDINATE EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS AND
EXTENTS OF ADDITIONAL HVAC WORK WITH MECHANICAL DRAWINGS.
H. UNO, REMOVE AND DISCARD CEILING ACCESS PANELS THAT ARE AFFECTED
BY THE DEMOLISHING OF GYPSUM BOARD CEILING TO ACCOMMODATE THE
HVAC SCOPE OF WORK.
I. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING.
CEILING DEMOLITION LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
TO BE
REMOVED
EXISTING TO REMAIN
WORK TO BE REMOVED
ASSUMED AREA OF SUSPENDED ACCOUSTICAL CEILING TILE
SYSTEM TO BE REMOVED AND SALVAGED FOR REINSTALLATION.
AREA SHOWN IS APPROXIMATE. REFER TO GENERAL NOTE ABOVE.
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
AD151
F
IR
S T
F L
O O
R C
E
IL
IN
G
D E
M O
L
IT
IO
N
P L
A N
A
R E
A A
-2
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING DEMOLITION PLAN - AREA A-2
1 REMOVE EXISTING GYP. BOARD CEILINGS IN AREA SHOWN TO COMPLETE
INSTALLATION AND RELOCATION OF DUCTWORK AND DEVICES. COORDINATE
DEVICE REQUIREMENTS WITHIN THIS AREA WITH OTHER DISCIPLINES.
REMOVAL SHALL INCLUDE ALL HANGERS, HARDWARE AND ALL RELATED
ACCESSORIES.
2 REMOVE EXISTING CEILING ACCESS PANEL AND SALVAGE FOR REUSE.
3 NO FINISHED CEILING THIS SPACE, OPEN TO STRUCTURE ABOVE.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
14 14
15 15
16 16
17 17
19 19
21x 21x
22 22
23 23
24 24
25 25
26 26
M.R
M.R
U.R
U.R
V.R
V.R
W.R
W.R
Y.R
Y.R
Z.R
Z.R
CC.R
CC.R
DD.R
DD.R
EE.R
EE.R
FF.R
FF.R
Px.R
Px.R
S.R
S.R
VESTIBULE
G103
STAIR #15
E132
LUGGAGE
E105A
LAUNDRY
E131
MECHANICAL
E130
STORAGE
E138
RECEPTION
E139
CORRIDOR
E140
MEN
E141
WOMEN
E142
CQ
E143
C O
R R
ID
O
R
E
1ST SGT
E119
CO OPS
COMMANDER
E120
STORAGE
E121
VESTIBULE
G103
OPS SGT
E123
CORRIDOR
G111
CORRIDOR
G112
CORRIDOR
G113
ELECTRICAL
G114
MEN
G115
STORAGE
G117
WOMEN
H110
STORAGE
H129
/MATCHLINE - A1 AD159
/MATCHLINE - A1 AD157
/MATCHLINE - A1 AD161
/MATCHLINE - A1 AD162
/MATCHLINE - A1 AD159
17' - 10"90' - 3"19' - 5"
127' - 6"
7' - 6"
WOMEN
D116
MEN
D115
3' - 11"
OUTDOOR TRAINING AREA
4' - 5"
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR GENERAL DEMOLITION NOTES.
B. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
C. REFER TO ELECTRICAL ('E' SERIES SHEETS) FOR INFORMATION REGARDING
REMOVAL AND SALVAGE OF AFFECTED DEVICES.
D. REFER TO FIRE PROTECTION ('F' SERIES SHEETS) FOR INFORMATION
REGARDING REMOVAL AND SALVAGE OF AFFECTED CEILING MOUNTED
DEVICES.
E. ALL FINISHES ARE EXISTING TO REMAIN UNO
F. DIMENSIONS SHOW AT GYPSUM BOARD DEMOLITION ARE ASSUMED EXTENTS
OF CEILING TO BE REMOVED TO COMPLETE WORK. CONTRACTOR TO REMOVE
GYPSUM CEILING AS NECESSARY TO COMPLETE WORK.
G. UNO, REMOVE AND SALVAGE FOR POSSIBLE RE-USE EXISTING SUSPENEDED
ACOUSTICAL CEILING TILE AND GRID AS REQUIRED TO PERFORM HVAC WORK
ABOVE. REMOVE TO NEAREST FULL TILE. WATER DAMAGED CEILING TILE AT
EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS ARE TO BE DISCARDED.
COORDINATE EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS AND
EXTENTS OF ADDITIONAL HVAC WORK WITH MECHANICAL DRAWINGS.
H. UNO, REMOVE AND DISCARD CEILING ACCESS PANELS THAT ARE AFFECTED
BY THE DEMOLISHING OF GYPSUM BOARD CEILING TO ACCOMMODATE THE
HVAC SCOPE OF WORK.
I. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING.
CEILING DEMOLITION LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
TO BE
REMOVED
EXISTING TO REMAIN
WORK TO BE REMOVED
ASSUMED AREA OF SUSPENDED ACCOUSTICAL CEILING TILE
SYSTEM TO BE REMOVED AND SALVAGED FOR REINSTALLATION.
AREA SHOWN IS APPROXIMATE. REFER TO GENERAL NOTE ABOVE.
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
AD158
F
IR
S T
F L
O O
R C
E
IL
IN
G
D E
M O
L
IT
IO
N
P L
A N
A
R E
A E
-2
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING DEMOLITION PLAN - AREA E-2
1 REMOVE EXISTING GYP. BOARD CEILINGS IN AREA SHOWN TO COMPLETE
INSTALLATION AND RELOCATION OF DUCTWORK AND DEVICES. COORDINATE
DEVICE REQUIREMENTS WITHIN THIS AREA WITH OTHER DISCIPLINES.
REMOVAL SHALL INCLUDE ALL HANGERS, HARDWARE AND ALL RELATED
ACCESSORIES.
2 REMOVE EXISTING CEILING ACCESS PANEL AND SALVAGE FOR REUSE.
3 NO FINISHED CEILING THIS SPACE, OPEN TO STRUCTURE ABOVE.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
13 13
14 14
16 16
19 19
22 22
23 23
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
Px.L
Px.L
U.L
U.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
U.R
U.R
Px.R
Px.R
S.R
S.R
OPS SGT
A123
CORRIDOR
G102
OPS SGT
E123
CORRIDOR
G104
CORRIDOR
G105
CORRIDOR
G106
ELECTRICAL
G107
STORAGE
G110
CORRIDOR
G111
CORRIDOR
G112
CORRIDOR
G113
ELECTRICAL
G114
MEN
G115
STORAGE
G117
CLASSROOM
G118
CLASSROOM
G121
/MATCHLINE - A1 AD162 /MATCHLINE - A1 AD162
/MATCHLINE - A1 AD151 /MATCHLINE - A1 AD158
/MATCHLINE - A1 AD159/MATCHLINE - A1 AD150
/MATCHLINE - A1 AD160
2 2
MEN
G108
4 4
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR GENERAL DEMOLITION NOTES.
B. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
C. REFER TO ELECTRICAL ('E' SERIES SHEETS) FOR INFORMATION REGARDING
REMOVAL AND SALVAGE OF AFFECTED DEVICES.
D. REFER TO FIRE PROTECTION ('F' SERIES SHEETS) FOR INFORMATION
REGARDING REMOVAL AND SALVAGE OF AFFECTED CEILING MOUNTED
DEVICES.
E. ALL FINISHES ARE EXISTING TO REMAIN UNO
F. DIMENSIONS SHOW AT GYPSUM BOARD DEMOLITION ARE ASSUMED EXTENTS
OF CEILING TO BE REMOVED TO COMPLETE WORK. CONTRACTOR TO REMOVE
GYPSUM CEILING AS NECESSARY TO COMPLETE WORK.
G. UNO, REMOVE AND SALVAGE FOR POSSIBLE RE-USE EXISTING SUSPENEDED
ACOUSTICAL CEILING TILE AND GRID AS REQUIRED TO PERFORM HVAC WORK
ABOVE. REMOVE TO NEAREST FULL TILE. WATER DAMAGED CEILING TILE AT
EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS ARE TO BE DISCARDED.
COORDINATE EXISTING FAN POWERED VAV EQUIPMENT LOCATIONS AND
EXTENTS OF ADDITIONAL HVAC WORK WITH MECHANICAL DRAWINGS.
H. UNO, REMOVE AND DISCARD CEILING ACCESS PANELS THAT ARE AFFECTED
BY THE DEMOLISHING OF GYPSUM BOARD CEILING TO ACCOMMODATE THE
HVAC SCOPE OF WORK.
I. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING.
CEILING DEMOLITION LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
TO BE
REMOVED
EXISTING TO REMAIN
WORK TO BE REMOVED
ASSUMED AREA OF SUSPENDED ACCOUSTICAL CEILING TILE
SYSTEM TO BE REMOVED AND SALVAGED FOR REINSTALLATION.
AREA SHOWN IS APPROXIMATE. REFER TO GENERAL NOTE ABOVE.
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
AD161
F
IR
S T
F L
O O
R C
E
IL
IN
G
D E
M O
L
IT
IO
N
P L
A N
A
R E
A G
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING DEMOLITION PLAN - AREA G
0 4' 8' 16'
1 REMOVE EXISTING GYP. BOARD CEILINGS IN AREA SHOWN TO COMPLETE
INSTALLATION AND RELOCATION OF DUCTWORK AND DEVICES. COORDINATE
DEVICE REQUIREMENTS WITHIN THIS AREA WITH OTHER DISCIPLINES.
REMOVAL SHALL INCLUDE ALL HANGERS, HARDWARE AND ALL RELATED
ACCESSORIES.
2 NO FINISHED CEILING THIS SPACE, OPEN TO STRUCTURE ABOVE.
3 UNO, REMOVE AND SALVAGE FOR POSSIBLE RE-USE EXISTING SUSPENEDED
ACOUSTICAL CEILING TILE AND GRID AS REQUIRED TO PERFORM HVAC WORK
ABOVE. WATER DAMAGED CEILING TILE AT EXISTING FPV LOCATIONS ARE TO
BE DISCARDED. COORDINATE EXISTING FPV LOCATIONS AND EXTENTS OF
ADDITIONAL HVAC WORK WITH MECHANICAL DRAWINGS.
4 REMOVE EXISTING CEILING ACCESS PANEL AND SALVAGE FOR REUSE.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
1 1
1/2
1/2 1/2
1/2
S S
1/2 1/2
13 13
14 14
15 15
16 16
19 19
22 22
23 23
24 24
26 26
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
Px.L
Px.L
U.L
U.L
W.L
W.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
U.R
U.R
W.R
W.R
Px.R
Px.R
S.R
S.R
/MATCHLINE - A1 A-126 /MATCHLINE - A1 A-126
/MATCHLINE - A1 A-115 /MATCHLINE - A1 A-122
/MATCHLINE - A1 A-123/MATCHLINE - A1 A-114
/MATCHLINE - A1 A-124
VIF
5' - 9"
VIF
5' - 9"
VIF
5' - 9" VIF
5' - 9"
VIF
5' - 9"
VIF
18' - 4"
A4
A-501
TYP
A4
A-501
SIM
OPEN AIR
HALLWAY
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR GENERAL DEMOLITION NOTES.
B. ALL FINISHES ARE EXISTING TO REMAIN UNO
C. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
D. ALL THRU-WALL PENETRATIONS AT RATED ASSEMBLIES ARE TO BE SEALED
TIGHT TO MAINTAIN CONTINUITY OF RATED PARTITION. PROVIDE
APPROPRIATE THRU PENETRATION FIRESTOPPING SYSTEM.
E. AT RATED PARITIONS, INFILL UN-USED OPENINGS LEFT BY DEMOLITION OF
EXISTING WORK USING TYPE 'X' (FIRE RESISTANT) GYPSUM BOARD AND METAL
STUD, UL ASSEMBLY U419 OR EQUIVILANT. PARTITION THICKNESS TO MATCH
EXISTING ADJACENT.
NEW WORK LEGEND
EXISTING TO REMAIN
NEW WORK
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
1/2 HOUR RATING
1 HOUR RATING
2 HOUR RATING
SMOKE PARTITION
PRESUMED LOCATIONS OF FIRE RATINGS. REFER TO G-SERIES SHEETS FOR
ADDITIONAL INFORMATION.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
A-125
R O
O F
P L
A N
A
R E
A G
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
SCALE: 1/8" = 1'-0"
A1
ROOF PLAN - AREA G
0 4' 8' 16'
1 EXISTING TPO ROOF MEMBRANE OVER RIGID INSULATION TO REMAIN. PATCH
AND REPAIR ROOF SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS AT REQUIRED LOCATIONS AFTER REMOVAL OF EXISTING
ROOF TOP MECHANICAL EQUIPMENT AND ASSOCIATED PIPING OR CONDUIT, AS
WELL AS LOCATIONS OF DAMAGE DURING CONSTRUCTION. PROVIDE RIGID
INSULATION INFILL TO MATCH EXISTING AS REQUIRED. CONTRACTOR IS TO
PROTECT MEMBRANE THROUGHOUT CONSTRUCTION FROM DAMAGE.
2 NEW MECHANICAL EQUIPMENT ON NEW OR MODIFIED CONCRETE
HOUSEKEEPING PAD. (REFER 'M' DRAWINGS). SEE F8/S-501 FOR MAXIMUM
EQUIPMENT WEIGHT TABLE.
3 NEW MECHANICAL EQUIPMENT ON MODIFIED EXISTING ROOF CURB. REFER TO
'M' DRAWINGS FOR NEW EQUIPMENT INFORMATION AND REFER TO
STRUCTURAL DRAWING (S-501) FOR EQUIPMENT SUPPORT DETAIL AND DETAIL
F8/S-501 FOR MAXIMUM EQUIPMENT WEIGHT TABLE.
4 NEW GALVANIZED CURB COPING FULL LENGTH OF ROOF CURB.
5 EXISTING ROOF FRAMING MEMBERS (OPEN WEB STEEL JOISTS OR STEEL
BEAMS - V.I.F., TO REMAIN) FOR SUPPORT OF NEW ROOF TOP MECHANICAL
EQUIPMENT. SEE DETAIL C5/S-501 FOR WEB REINFORCEMENT REQUIREMENTS
AT EXISTING JOISTS AND A5/S-501 FOR SUPPORT DETAIL BELOW MECHANICAL
EQUIPMENT CURB.
6 NEW MECHANICAL EQUIPMENT ON NEW CURB. (REFER 'M' DRAWINGS)
7 PATCH AREA OF TPO ROOFING MEMBRANE DUE TO REMOVAL FOR NEW
EQUIPMENT PENTRATION. NEW INSULATION TO MATCH EXISTING IN TYPE AND
IN SLOPE TO DRAIN. NEW TPO MEMBRANE TO BE INSTALLED PER
MANUFACTUERS STANDARD DETAILS FOR CURB APPLICATION AND LAPPING OF
EXISTING MEMBRANE WITH NEW PATCH. SEAL CUT EDGES OF TPO MEMBRANE
PER MANUFACTURERS REQUIREMENTS. PROVIDE NEW ROOF PENETRATION
FRAMING PER DETAIL C8/S-501.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
14 14
15 15
16 16
17 17
19 19
21x 21x
22 22
23 23
24 24
25 25
26 26
M.L
M.L
Px.L
Px.L
U.L
U.L
V.L
V.L
W.L
W.L
Y.L
Y.L
Z.L
Z.L
CC.L
CC.L
DD.L
DD.L
EE.L
EE.L
FF.L
FF.L
S.L
S.L
21 21
/MATCHLINE - A1 A-150
/MATCHLINE - A1 A-152
/MATCHLINE - A1 A-161
/MATCHLINE - A1 A-162
/MATCHLINE - A1 A-150
17' - 10" 90' - 3" 19' - 5"
127' - 6"
STAIR #5
A106
LUGGAGE
A105A
LAUNDRY
A105
MECHANICAL
A104
STORAGE
A112
RECEPTION
A113
CORRIDOR
A114
MEN
A115
WOMEN
A116
CQ
A117
C O
R R
ID
O
R
A
1ST SGT
A119
CO OPS
COMMANDER
A120
STORAGE
A121
VESTIBULE
G101
OPS SGT
A123
CORRIDOR
G104
CORRIDOR
G105
CORRIDOR
G106
ELECTRICAL
G107
MEN
G108
STORAGE
G110
WOMEN
H102
STORAGE
H122
CORRIDOR
A122
TYP
OUTDOOR TRAINING AREA
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR PROJECT GENERAL NOTES.
B. THE REFLECTED CEILING PLANS ARE INTENDED TO AID IN COORDINATION.
REFER TO MECHANICAL, ELECTRICAL, TECHNOLOGY, AND FIRE PROTECTION
DRAWINGS FOR ADDITIONAL CEILING DEVICE INFORMATION.
C. ALL NOTED CEILING HEIGHTS ARE CLEAR HEIGHTS TO FINISHED CEILING.
COORDINATE HEIGHT OF ALL SYSTEMS ABOVE CEILING PRIOR TO INSTALL.
NEW CEILING HEIGHTS ARE TO MATCH EXISTING UNO.
D. ALL FINISHES ARE EXISTING TO REMAIN, U.N.O.
E. REFER TO A-601 FOR FINISH SCHEDULE.
F. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
G. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING. CONTRACTOR TO
REPAIR TOP OF WALL AND COLUMN LOCATIONS TO LIKE NEW CONDITION.
WORK AREA TO BE PAINTED, P1. TERMINATE WITH STRAIGHT LEVEL LINE.
REFER TO DETAIL ON A-501.
H. AT RATED PARITIONS, INFILL UN-USED OPENINGS LEFT BY DEMOLITION OF
EXISTING WORK USING TYPE 'X' (FIRE RESISTANT) GYPSUM BOARD AND METAL
STUD, UL ASSEMBLY U419 OR EQUIVILANT. PARTITION THICKNESS TO MATCH
EXISTING ADJACENT.
I. NEW ACCESS PANELS SHOWN ARE DIAGRAMATIC AND SHALL BE LOCATED TO
SERVE MECHANICAL EQUIPMENT ABOVE. ACCESS PANELS OTHER THAN
THOSE SHOWN MAY BE REQUIRED, COORDINATE LOCATION WITH
MECHANICAL DRAWINGS.
J. INSTALL SALVAGED ACOUSTICAL CEILING TILE AND GRID REMOVED TO
ACCOMMODATE HVAC WORK ABOVE CEILING. PROVIDE NEW CEILING TILE AT
LOCATIONS WHERE WATER DAMAGED TILE WAS DISCARDED. NEW TILE
QUANTITY TO BE LIMITED TO:
a. AREAS 'A' THRU 'E'
• MAX. 385 TILES (TOTAL FOR ALL AREAS)
b. AREAS 'F' THRU 'H' INCLUDING HALLWAYS SERVING THESE AREAS
• MAX. 2,000 TILES (TOTAL FOR ALL AREAS)
CEILING LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
NEW /
RE-INSTALLED
EXISTING TO REMAIN
NEW WORK
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE - EMERGENCY
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
A-151
F
IR
S T
F L
O O
R C
E
IL
IN
G
P L
A N
A
R E
A A
-2
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING PLAN - AREA A-2
1 NEW 5/8" GYPSUM BOARD CEILING, PAINTED. HEIGHT AS SHOWN OR TO MATCH
EXISTING ADJACENT AT INFILL LOCATIONS.
2 NEW 5/8" MOISTURE RESISTANT GYPSUM BOARD CEILING, PAINTED. HEIGHT AS
SHOWN OR TO MATCH EXISTING ADJACENT AT INFILL LOCATIONS.
3 INSTALL SALVAGED CEILING ACCESS PANEL. COORDINATE FINAL INSTALL
LOCATION IN FIELD WITH MECHANICAL UNIT REQUIREMENTS ABOVE.
4 NEW 24"x36" CEILING ACCESS PANEL. COORDINATE FINAL INSTALL LOCATION IN
FIELD WITH MECHANICAL UNIT REQUIREMENTS ABOVE.
5 RE-INSTALL EXISTING ACOUSTICAL CEILING AND GRID REMOVED TO
ACCOMMODATE WORK ABOVE CEILING. REPLACE WATER DAMAGED CEILING
TILES AS OUTLINED IN GENERAL NOTES.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
14 14
15 15
16 16
17 17
19 19
21x 21x
22 22
23 23
24 24
25 25
26 26
M.R
M.R
U.R
U.R
V.R
V.R
W.R
W.R
Y.R
Y.R
Z.R
Z.R
CC.R
CC.R
DD.R
DD.R
EE.R
EE.R
FF.R
FF.R
Px.R
Px.R
S.R
S.R
/MATCHLINE - A1 A-159
/MATCHLINE - A1 A-157
/MATCHLINE - A1 A-161
/MATCHLINE - A1 A-162
/MATCHLINE - A1 A-159
17' - 10"90' - 3"19' - 5"
127' - 6"
VESTIBULE
G103
STAIR #15
E132
LUGGAGE
E105A
LAUNDRY
E131
MECHANICAL
E130
STORAGE
E138
RECEPTION
E139
CORRIDOR
E140
MEN
E141
WOMEN
E142
CQ
E143
C O
R R
ID
O
R
E
1ST SGT
E119
CO OPS
COMMANDER
E120
STORAGE
E121
OPS SGT
E123
CORRIDOR
G111
CORRIDOR
G112
CORRIDOR
G113
ELECTRICAL
G114
MEN
G115
STORAGE
G117
WOMEN
H110
STORAGE
H129
TYP
4 1
OUTDOOR TRAINING AREA
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR PROJECT GENERAL NOTES.
B. THE REFLECTED CEILING PLANS ARE INTENDED TO AID IN COORDINATION.
REFER TO MECHANICAL, ELECTRICAL, TECHNOLOGY, AND FIRE PROTECTION
DRAWINGS FOR ADDITIONAL CEILING DEVICE INFORMATION.
C. ALL NOTED CEILING HEIGHTS ARE CLEAR HEIGHTS TO FINISHED CEILING.
COORDINATE HEIGHT OF ALL SYSTEMS ABOVE CEILING PRIOR TO INSTALL.
NEW CEILING HEIGHTS ARE TO MATCH EXISTING UNO.
D. ALL FINISHES ARE EXISTING TO REMAIN, U.N.O.
E. REFER TO A-601 FOR FINISH SCHEDULE.
F. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
G. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING. CONTRACTOR TO
REPAIR TOP OF WALL AND COLUMN LOCATIONS TO LIKE NEW CONDITION.
WORK AREA TO BE PAINTED, P1. TERMINATE WITH STRAIGHT LEVEL LINE.
REFER TO DETAIL ON A-501.
H. AT RATED PARITIONS, INFILL UN-USED OPENINGS LEFT BY DEMOLITION OF
EXISTING WORK USING TYPE 'X' (FIRE RESISTANT) GYPSUM BOARD AND METAL
STUD, UL ASSEMBLY U419 OR EQUIVILANT. PARTITION THICKNESS TO MATCH
EXISTING ADJACENT.
I. NEW ACCESS PANELS SHOWN ARE DIAGRAMATIC AND SHALL BE LOCATED TO
SERVE MECHANICAL EQUIPMENT ABOVE. ACCESS PANELS OTHER THAN
THOSE SHOWN MAY BE REQUIRED, COORDINATE LOCATION WITH
MECHANICAL DRAWINGS.
J. INSTALL SALVAGED ACOUSTICAL CEILING TILE AND GRID REMOVED TO
ACCOMMODATE HVAC WORK ABOVE CEILING. PROVIDE NEW CEILING TILE AT
LOCATIONS WHERE WATER DAMAGED TILE WAS DISCARDED. NEW TILE
QUANTITY TO BE LIMITED TO:
a. AREAS 'A' THRU 'E'
• MAX. 385 TILES (TOTAL FOR ALL AREAS)
b. AREAS 'F' THRU 'H' INCLUDING HALLWAYS SERVING THESE AREAS
• MAX. 2,000 TILES (TOTAL FOR ALL AREAS)
CEILING LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
NEW /
RE-INSTALLED
EXISTING TO REMAIN
NEW WORK
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE - EMERGENCY
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
A-158
F
IR
S T
F L
O O
R C
E
IL
IN
G
P L
A N
A
R E
A E
-2
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING PLAN - AREA E-2
1 NEW 5/8" GYPSUM BOARD CEILING, PAINTED. HEIGHT AS SHOWN OR TO MATCH
EXISTING ADJACENT AT INFILL LOCATIONS.
2 NEW 5/8" MOISTURE RESISTANT GYPSUM BOARD CEILING, PAINTED. HEIGHT AS
SHOWN OR TO MATCH EXISTING ADJACENT AT INFILL LOCATIONS.
3 INSTALL SALVAGED CEILING ACCESS PANEL. COORDINATE FINAL INSTALL
LOCATION IN FIELD WITH MECHANICAL UNIT REQUIREMENTS ABOVE.
4 NEW 24"x36" CEILING ACCESS PANEL. COORDINATE FINAL INSTALL LOCATION IN
FIELD WITH MECHANICAL UNIT REQUIREMENTS ABOVE.
5 RE-INSTALL EXISTING ACOUSTICAL CEILING AND GRID REMOVED TO
ACCOMMODATE WORK ABOVE CEILING. REPLACE WATER DAMAGED CEILING
TILES AS OUTLINED IN GENERAL NOTES.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
13 13
14 14
16 16
19 19
22 22
23 23
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
Px.L
Px.L
U.L
U.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
U.R
U.R
Px.R
Px.R
S.R
S.R
/MATCHLINE - A1 A-162 /MATCHLINE - A1 A-162
/MATCHLINE - A1 A-151 /MATCHLINE - A1 A-158
/MATCHLINE - A1 A-159/MATCHLINE - A1 A-150
/MATCHLINE - A1 A-160
OPS SGT
A123
CORRIDOR
G102
OPS SGT
E123
CONF. TRAINING
E124
CORRIDOR
G104
CORRIDOR
G105
CORRIDOR
G106
ELECTRICAL
G107
MEN
G108
STORAGE
G110
CORRIDOR
G111
CORRIDOR
G112
CORRIDOR
G113
ELECTRICAL
G114
MEN
G115
STORAGE
G117
CLASSROOM
G118
CLASSROOM
G121
CORRIDOR
A122
TYP
TYP
1 TYP
TYP
10' - 0" 10' - 0"
TYP
3 3
DRAWING SHEET NOTES
GENERAL SHEET NOTES
A. REFER TO SHEET A-001 FOR PROJECT GENERAL NOTES.
B. THE REFLECTED CEILING PLANS ARE INTENDED TO AID IN COORDINATION.
REFER TO MECHANICAL, ELECTRICAL, TECHNOLOGY, AND FIRE PROTECTION
DRAWINGS FOR ADDITIONAL CEILING DEVICE INFORMATION.
C. ALL NOTED CEILING HEIGHTS ARE CLEAR HEIGHTS TO FINISHED CEILING.
COORDINATE HEIGHT OF ALL SYSTEMS ABOVE CEILING PRIOR TO INSTALL.
NEW CEILING HEIGHTS ARE TO MATCH EXISTING UNO.
D. ALL FINISHES ARE EXISTING TO REMAIN, U.N.O.
E. REFER TO A-601 FOR FINISH SCHEDULE.
F. CONTRACTOR IS TO ANTICIPATE WORK AT ALL THRU-WALL AND FLOOR
PENETRATIONS. EXISTING OPENINGS ARE TO BE USED WHERE POSSIBLE AND
INCREASE/DECREASE IN SIZE AS REQUIRED. PROVIDE NEW OPENINGS WHERE
EXISTING OPENINGS ARE NOT PRESENT. SIZE OF OPENING TO BE
DETERMINED BY PENETRATING ELEMENT, INCLUDING BUT NOT LIMITED TO
DUCT, PIPING, AND THEIR REQUIRED ACCESSORIES. COORDINATE OPENING
SIZE AND LOCATION USING MECHANICAL AND ELECTRICAL DRAWINGS.
G. CONTRACTOR TO LIMIT EXTENT OF WORK AT CEILING-TO-WALL AND CEILING-
TO-COLUMN TRANSITIONS TO 6" BELOW FINISHED CEILING. CONTRACTOR TO
REPAIR TOP OF WALL AND COLUMN LOCATIONS TO LIKE NEW CONDITION.
WORK AREA TO BE PAINTED, P1. TERMINATE WITH STRAIGHT LEVEL LINE.
REFER TO DETAIL ON A-501.
H. AT RATED PARITIONS, INFILL UN-USED OPENINGS LEFT BY DEMOLITION OF
EXISTING WORK USING TYPE 'X' (FIRE RESISTANT) GYPSUM BOARD AND METAL
STUD, UL ASSEMBLY U419 OR EQUIVILANT. PARTITION THICKNESS TO MATCH
EXISTING ADJACENT.
I. NEW ACCESS PANELS SHOWN ARE DIAGRAMATIC AND SHALL BE LOCATED TO
SERVE MECHANICAL EQUIPMENT ABOVE. ACCESS PANELS OTHER THAN
THOSE SHOWN MAY BE REQUIRED, COORDINATE LOCATION WITH
MECHANICAL DRAWINGS.
J. INSTALL SALVAGED ACOUSTICAL CEILING TILE AND GRID REMOVED TO
ACCOMMODATE HVAC WORK ABOVE CEILING. PROVIDE NEW CEILING TILE AT
LOCATIONS WHERE WATER DAMAGED TILE WAS DISCARDED. NEW TILE
QUANTITY TO BE LIMITED TO:
a. AREAS 'A' THRU 'E'
• MAX. 385 TILES (TOTAL FOR ALL AREAS)
b. AREAS 'F' THRU 'H' INCLUDING HALLWAYS SERVING THESE AREAS
• MAX. 2,000 TILES (TOTAL FOR ALL AREAS)
CEILING LEGEND
2' x 2' ACT CEILING
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
GYP. BD. CEILING
EXISTING TO
REMAIN
NEW /
RE-INSTALLED
EXISTING TO REMAIN
NEW WORK
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE - EMERGENCY
CEILING ACCESS PANEL
REFER TO MECHANICAL, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR
FIXTURE/DEVICE INFORMATION.
MASONRY WALL CONSTRUCTION
GYPSUM BOARD ON METAL STUD CONSTRUCTION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
F
IL
E N
U M
B E
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
A-161
F
IR
S T
F L
O O
R C
E
IL
IN
G
P L
A N
A
R E
A G
F O
R T
B E
N N
IN
G
G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T W
O
G L
E T
H O
R P
E A
V E
S A
V A
N N
A H
G
E O
R G
IA
R .F
U S
S N
E R
M H
A Y
N E
S
A H
A U
T M
A N
J K
O L S
H O
R N
A U
G U
S T
W H
N -2
-B
-4
READY TO ADVERTISE (RTA)
B U
IL
D
IN
G
H
E A
T
IN
G
V E
N T
IL
A
T
IO
N
A
IR
C
O N
D
IT
IO
N
IN
G
H
V A
C
R E
P A
IR
P
BLDG 3425
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR CEILING PLAN - AREA G
0 4' 8' 16'
1 RE-INSTALL EXISTING ACOUSTICAL CEILING AND GRID REMOVED TO
ACCOMMODATE WORK ABOVE CEILING. REPLACE WATER DAMAGED CEILING
TILES AS OUTLINED IN GENERAL NOTES.
2 NEW 5/8" MOISTURE RESISTANT GYPSUM BOARD CEILING, PAINTED. HEIGHT AS
SHOWN OR TO MATCH EXISTING ADJACENT AT INFILL LOCATIONS.
3 INSTALL SALVAGED CEILING ACCESS PANEL. COORDINATE FINAL INSTALL
LOCATION IN FIELD WITH MECHANICAL UNIT REQUIREMENTS ABOVE.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
1 1
14 14
15 15
16 16
17 17
19 19
21 21
22 22
23 23
24 24
25 25
26 26
M.L
M.L
P.L
P.L
U.L
U.L
V.L
V.L
W.L
W.L
Y.L
Y.L
Z.L
Z.L
BB.L
BB.L
CC.L
CC.L
DD.L
DD.L
EE.L
EE.L
FF.L
FF.L
S.L
S.L
STAIR #5
A106
LUGGAGE
A105A
LAUNDRY
A105
MECHANICAL
A104
STORAGE
A112
RECEPTION
A113
CORRIDOR
A114
MEN
A115
WOMEN
A116
CQ
A117
CORRIDOR
A118
1ST SGT
A119
CO OPS
COMMANDER
A120
VESTIBULE
G101
MEN
B115
WOMEN
B116
CORRIDOR
G104
ELECTRICAL
G107
MEN
G108
WOMEN
H102
STORAGE
H122
FPV-A2-1 (E)
EUH-A2 (E)
BBH-B (E)
BBH-A (E)
BBH-C (E)
BBH-E (E)
CUH-G1 (E)
FPV-A2-9 (E)
/MATCHLINE A1 MD101
/MATCHLINE A1 MD103
M
AT
C
H
LI
N E
A
M D
M
AT
C
H
LI
N E
A
M D
/MATCHLINE A1 MD101
/MATCHLINE A1 MD103
M
AT
C
H
LI
N E
A
M D
M
AT
C
H
LI
N E
A
M D
MD402
A1
2"
2" CHWR
1" CHWS/R
4" CHWR
1" CHWS/R
1 1/4" HWR UP3
1 1/4" HWS UP
2" CHWS UP
2" CHWR UP
EUH-A6 (E)1
FPV-A2-2 (E)
DRAWING SHEET NOTES #
US Army Corps of Engineers ®
SHEET ID
U S A R M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
M A R K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
FI
LE
N U
M
BE
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
MD102
FI
R
ST
F
LO
O R D
EM
O
LI
TI
O N M
EC
H A N
IC
A L
PL
A N
A R
EA
A -2
FO
R T B
EN
N
IN
G , G
EO
R G
IA
SA
VA
N N A H D
IS
TR
IC
T
W . O G
LE
TH
O R
PE
A
VE
SA
VA
N N A H , G
EO
R G
IA
D . L
AW
D . H
AS
EN
KA
M
P
A.
H
AU
TM
AN
D . G
IB
BS
AU
G
U
ST
, 2
W
2H N
-2 2-
B-
READY TO ADVERTISE
B U
IL
D
IN
G H
EA
TI
N G , V
EN
TI
LA
TI
O N
A
IR
C O N D
IT
IO
N
IN
G (H
VA
C ) R
EP
A
IR
P
BLDG 3425
0 4' 8' 16' 1/8" = 1'-0"A1 FIRST FLOOR DEMOLITION MECHANICAL PLAN - AREA A-2
1 EQUIPMENT TO REMAIN.
2 DEMOLISH FAN-POWERED VAV BOX (FPV) AND ASSOCIATED CONTROLS
INCLUDING THERMOSTAT. DEMOLISH ASSOCIATED CHILLED WATER SUPPLY
AND RETURN PIPING BACK TO MAIN AND CAP. HOT WATER PIPING TO
REMAIN. DEMOLISH CONDENSATE PIPING AND DRAIN PAN.
3 CAP OUTSIDE AIR DUCT BELOW FLOOR SLAB.
4 PATCH REMAINING DUCT OPENING.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 8/
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 4/
14 14
15 15
16 16
17 17
19 19
21 21
22 22
23 23
24 24
25 25
26 26
M.R
M.R
U.R
U.R
V.R
V.R
W.R
W.R
Y.R
Y.R
Z.R
Z.R
BB.R
BB.R
CC.R
CC.R
DD.R
DD.R
EE.R
EE.R
FF.R
FF.R
P.R
P.R
S.R
S.R
M
AT
C
H
LI
N E
A
M -1
VESTIBULE
G103
MEN
D115
WOMEN
D116
STAIR #15
E132
LUGGAGE
E105A LAUNDRY
E131
MECHANICAL
E130
STORAGE
E138
RECEPTION
E139
CORRIDOR
E140
MEN
E141
WOMEN
E142
CQ
E143
CORRIDOR
E144
1ST SGT
E119
CO OPS
COMMANDER
E120
STORAGE
E121
OPS SGT
E123
CORRIDOR
G111
CORRIDOR
G112
ELECTRICAL
G114
MEN
G115
WOMEN
H110STORAGE
H129
FPV-E2-2 (E)
FPV-E2-9 (E)
M
AT
C
H
LI
N E
A
M D
M
AT
C
H
LI
N E
A
M D
/MATCHLINE A1 MD108
M
AT
C
H
LI
N E
A
M D
M
AT
C
H
LI
N E
A
M D
/MATCHLINE A1 MD108
MD402
A1
4" C
H W
R (E
FPV-E2-1 (E)
DRAWING SHEET NOTES #
US Army Corps of Engineers ®
SHEET ID
U S A R M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
M A R K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
FI
LE
N U
M
BE
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
MD109
FI
R
ST
F
LO
O R D
EM
O
LI
TI
O N M
EC
H A N
IC
A L
PL
A N
A R
EA
E -2
FO
R T B
EN
N
IN
G , G
EO
R G
IA
SA
VA
N N A H D
IS
TR
IC
T
W . O G
LE
TH
O R
PE
A
VE
SA
VA
N N A H , G
EO
R G
IA
D . L
AW
D . H
AS
EN
KA
M
P
A.
H
AU
TM
AN
D . G
IB
BS
AU
G
U
ST
, 2
W
2H N
-2 2-
B-
READY TO ADVERTISE
B U
IL
D
IN
G H
EA
TI
N G , V
EN
TI
LA
TI
O N
A
IR
C O N D
IT
IO
N
IN
G (H
VA
C ) R
EP
A
IR
P
BLDG 3425
0 4' 8' 16'
1/8" = 1'-0"A1 FIRST FLOOR DEMOLITION MECHANICAL PLAN - AREA E-2
1 DEMOLISH FAN-POWERED VAV BOX (FPV) AND ASSOCIATED CONTROLS
INCLUDING THERMOSTAT. DEMOLISH ASSOCIATED CHILLED WATER SUPPLY
AND RETURN PIPING BACK TO MAIN AND CAP. HOT WATER PIPING TO
REMAIN. DEMOLISH CONDENSATE PIPING AND DRAIN PAN.
2 CAP OUTSIDE AIR DUCT BELOW FLOOR SLAB.
3 EQUIPMENT TO REMAIN.
4 PATCH REMAINING DUCT OPENING.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 8/
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 4/
14 14
15 15
16 16
17 17
19 19
21 21
22 22
23 23
24 24
25 25
26 26
M.L
M.L
P.L
P.L
U.L
U.L
V.L
V.L
W.L
W.L
Y.L
Y.L
Z.L
Z.L
BB.L
BB.L
CC.L
CC.L
DD.L
DD.L
EE.L
EE.L
FF.L
FF.L
S.L
S.L
/MATCHLINE A1 M-101
/MATCHLINE A1 M-103
M
AT
C
H
LI
N E
A
M -1
M
AT
C
H
LI
N E
A
M -1
STAIR #5
A106
LUGGAGE
A105A
LAUNDRY
A105
MECHANICAL
A104
RECEPTION
A113
CORRIDOR
A114
MEN
A115
WOMEN
A116
CQ
A117
CORRIDOR
A118
1ST SGT
A119
CO OPS
COMMANDER
A120
OPS SGT
A123
MEN
B115
CORRIDOR
G104
CORRIDOR
G105
ELECTRICAL
G107
MEN
G108
WOMEN
H102
EUH-A2 (E)
BBH-E (E)
CUH-G1 (E)
BBH-E (E)
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
52" x 20" EA (E) 14" x 10" SA (E)
6" x 6" EA (E)
6" x 6" EA (E)
6" x 6" EA (E)
6" x 6" EA (E) 6" x 6" EA (E)
6" x 6" EA (E)
3/4" HWS/R
4" CHWR (E)
4" CHWR (E)
" x
8"
E A
M-402 A1
2 1/2" CHWS UP
2 1/2" CHWR UP
46" x 18" RA UP
50" x 18" SA (E)
26" x 18" SA (E)
" x
" E
A E
8"ø X
VESTIBULE
G101
12" x 6" RA
50" x 18" SA (E)
VAV-H1-6
12"ø A
14"ø B
4"ø A
VAV-H1-1
FCU-A-2
" x
0"
S A
(E
10" Ø SA (E)
6"ø A
6"ø A
T
6" x 8" SA (E)
10" Ø SA (E)
6" Ø SA (E)
10" x 10" SA (E)
STORAGE
A112
4"ø A
65VAV-A2-2 1/2" HWR (E)
1/2" HWS (E)
1/2" HWS
1/2" HWR (E)
1/2" HWS (E)
VAV-A2-1
1/2" HWR
1/2" HWS
6"ø B
10" x 8" RA
6"ø B
8"ø B
4"ø B
8" x 10" RA
10" Ø SA UP
6"ø X
6"ø X
6"ø X
6"ø X
STORAGE
A121
26" x 18" SA (E)
10"x6" X
8"x6" X
6"ø X
6"ø C
6"ø C
10" Ø SA
14" x 12" RA UP
6" Ø EA
58" x 14" RA
MVD
12"x12" B
E6 M-301
10"x10" X
8"x8" X
14"x10" EA 14"x10" EA
" x
8"
R A
OS
12"ø B
DRAWING SHEET NOTES #
US Army Corps of Engineers ®
SHEET ID
U S A R M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
M A R K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
FI
LE
N U
M
BE
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
M-102
FI
R
ST
F
LO
O R M
EC
H A N
IC
A L
PL
A N A R
EA
A -2
FO
R T B
EN
N
IN
G , G
EO
R G
IA
SA
VA
N N A H D
IS
TR
IC
T
W . O G
LE
TH
O R
PE
A
VE
SA
VA
N N A H , G
EO
R G
IA
D . L
AW
D . H
AS
EN
KA
M
P
A.
H
AU
TM
AN
D . G
IB
BS
AU
G
U
ST
, 2
W
2H N
-2 2-
B-
READY TO ADVERTISE
B U
IL
D
IN
G H
EA
TI
N G , V
EN
TI
LA
TI
O N
A
IR
C O N D
IT
IO
N
IN
G (H
VA
C ) R
EP
A
IR
P
BLDG 3425
0 4' 8' 16' 1/8" = 1'-0"A1 FIRST FLOOR MECHANICAL PLAN - AREA A-2
1 UNLESS OTHERWISE NOTED, EXISTING HWS/R PIPE RUNOUTS ARE 1" IN
DIAMETER.
2 12"x6" EA UP TO EF-G-3 ON ROOF
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 8/
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 4/
14 14
15 15
16 16
17 17
19 19
21 21
22 22
23 23
24 24
25 25
26 26
M.R
M.R
U.R
U.R
V.R
V.R
W.R
W.R
Y.R
Y.R
Z.R
Z.R
BB.R
BB.R
CC.R
CC.R
DD.R
DD.R
EE.R
EE.R
FF.R
FF.R
P.R
P.R
S.R
S.R
M
AT
C
H
LI
N E
A
M -1
/MATCHLINE A1 M-108
VESTIBULE
G103
MEN
D115
WOMEN
D116
STAIR #15
E132
LUGGAGE
E105A
LAUNDRY
E131
MECHANICAL
E130
STORAGE
E138
RECEPTION
E139
CORRIDOR
E140
MEN
E141
WOMEN
E142
CQ
E143
C O
R R
ID
O
R E1
1ST SGT
E119
CO OPS
COMMANDER
E120
STORAGE
E121
C O
R R
ID
O
R G
CORRIDOR
G112
ELECTRICAL
G114
MEN
G115
STORAGE
G117
WOMEN
H110
1" HWR (E)
1" HWS (E)
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6" x 6" EA E6" x 6" EA (E)
6" x 6" EA E6" x 6" EA E6" x 6" EA (E)
6" x 6" EA (E)
M-402 A1
" x
2"
E A
E
(ON ROOF)
OAI-G2 (E)
24" x 12" EA (E)
VAV-H2-5
26" x 10" SA (E)
46" x 18" RA UP
2 1/2" CHWS UP
2 1/2" CHWR UP
3" HWR (E)
3" HWS (E)
52" x 20" RA UP
38" x 18" RA
" x
8"
R A
1/2" HWR
1/2" HWS
8"ø A
FCU-E-2
VAV-E2-1
VAV-E2-2
8"ø A
6"ø B
10" x 8" RA
6"ø B
8"ø B
4"ø B
8" x 10" RA
4"ø A
4"ø B
50" x 18" SA (E)
4" C
H W
R (E
4"
C H
W S
(E
1" HWS (E)
1" HWR (E)
1/2" HWR (E)
1/2" HWS (E)
6"ø X
6"ø X
6"ø X
6"ø X
6"ø A
6"ø X
2 1/2" CHWS
2 1/2" CHWR
5" Ø SA
14" x 12" RA UP
6" x 10" RA
4" Ø RA
5" Ø SA
58" x 14" RA
12"x12" B
8"ø X
12"ø A
8"x6" X
8"x6" X
14" Ø RA
14" Ø RA
14" Ø RA
14" Ø RA
14" Ø RA
14"x10" EA
OS
12"ø B
DRAWING SHEET NOTES #
US Army Corps of Engineers ®
SHEET ID
U S A R M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
M A R K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
FI
LE
N U
M
BE
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
M-109
FI
R
ST
F
LO
O R M
EC
H A N
IC
A L
PL
A N A R
EA
E -2
FO
R T B
EN
N
IN
G , G
EO
R G
IA
SA
VA
N N A H D
IS
TR
IC
T
W . O G
LE
TH
O R
PE
A
VE
SA
VA
N N A H , G
EO
R G
IA
D . L
AW
D . H
AS
EN
KA
M
P
A.
H
AU
TM
AN
D . G
IB
BS
AU
G
U
ST
, 2
W
2H N
-2 2-
B-
READY TO ADVERTISE
B U
IL
D
IN
G H
EA
TI
N G , V
EN
TI
LA
TI
O N
A
IR
C O N D
IT
IO
N
IN
G (H
VA
C ) R
EP
A
IR
P
BLDG 3425
0 4' 8' 16'
1/8" = 1'-0"A1 FIRST FLOOR MECHANICAL PLAN - AREA E-2
1 12"x6" EA UP TO EF-G-4 ON ROOF
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 8/
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 4/
2 2
13 13
14 14
16 16
19 19
22 22
23 23
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
P.L
P.L
U.L
U.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
U.R
U.R
P.R
P.R
S.R
S.R
M
AT
C
H
LI
N E
A
M -1
/MATCHLINE A1 M-111
/MATCHLINE A1 M-113
M
AT
C
H
LI
N E
A
M -1
OPS SGT
A123
CORRIDOR
G102
STORAGE
F123
S3 OPERATIONS
F128
CORRIDOR
G105
CORRIDOR
G106
ELECTRICAL
G107
MEN
G108
STORAGE
G110
C O
R R
ID
O
R G
CORRIDOR
G112
CORRIDOR
G113
ELECTRICAL
G114
MEN
G115
STORAGE
G117
CLASSROOM
G118
CLASSROOM
G121
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
14" x 12" SA (E) 20" x 12" SA (E)
8" Ø SA (E)
VAV-H1-5
24" x 12" EA (E)
14" x 12" SA (E) 20" x 12" SA (E)
14" x 12" SA (E) 20" x 12" SA (E)
20" x 12" SA (E)14" x 12" SA (E)
20" x 12" SA (E)14" x 12" SA (E)
" x
6"
S A
E
10" Ø SA14" x 10" SA (E)
6" x 6" EA (E)
6" x 6" EA (E)
6" x 6" EA (E)
6" x 6" EA (E) 6" x 6" EA (E)
6" x 6" EA (E)
24" x 12" EA (E)
3/4" HWS/R
4" CHWR (E)
4" CHWR (E)
3/4" HWS/R
2" HWS (E)
2" HWR (E)
3/4" HWS/R
3/4" HWS/R
2" HWR (E)
2" HWS (E)
3/4" HWS/R
2" HWS (E)
2" HWR (E)
2" HWR (E)
2" HWS (E)
3/4" HWS/R
2" HWS (E)
2" HWS (E)
2" HWR (E)
2" HWR (E)
2" HWS (E)
VAV-H2-2
10" Ø SA
10" Ø SA
3/4" HWS/R
3/4" HWS/R
10" Ø SA
10" Ø SA
2" HWR
3/4" HWS/R
10" Ø SA
10" Ø SA10" Ø SA
3/4" HWS/R
10" Ø SA 10" Ø SA
2" HWR (E)
2" HWS (E)
20" x 12" SA (E) 14" x 12" SA (E)
8" Ø SA (E)
20" x 12" SA (E) 14" x 12" SA (E)
14" x 12" SA (E)20" x 12" SA (E)
14" x 12" SA (E)20" x 12" SA (E)
20" x 12" SA (E) 14" x 12" SA (E)
10" Ø SA
VAV-H2-1
1" HWR (E)
1" HWS (E)3/4" HWS/R
8" Ø
S A
" x
8"
E A
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6"x6" X
6" x 6" EA E6" x 6" EA (E)
6" x 6" EA E6" x 6" EA E6" x 6" EA (E)
6" x 6" EA (E)
" x
2"
E A
E
(ON ROOF)
OAI-G2 (E)
24" x 12" EA (E)4" CHWR (E)
4" CHWS (E)
6" Ø SA VAV-H2-5
26" x 10" SA (E)
" x
6"
S A
50" x 18" SA (E)
3" HWR (E)
3" HWS (E)
S3 OFFICE
F128A
5" Ø SA
T
T
T
T
T
T
T T
T T
14" x 10" SA (E)
50" x 18" SA (E)
38" x 18" RA
" x
8"
R A
VAV-H1-2
VAV-H1-3
VAV-H1-4
VAV-H1-13 VAV-H2-14
VAV-H1-15
VAV-H2-16
VAV-H2-4
VAV-H2-3
1/2" HWR
1/2" HWS
6"ø A
12"ø A
10"ø A
14"ø B
10"ø A 24010"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A 240 10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
10"ø A
8"ø A
VAV-H1-1
6"ø A
4"ø A
651/2" HWR (E)
1/2" HWS (E)
1/2" HWS
1/2" HWR
4"ø B
8"ø B
4" CHWR (E)
4" CHWS (E)
3" HWR (E)
3" HWR (E)
3" HWS (E)
4" CHWS (E)
4" CHWR (E)
8"ø A
6"ø B
4"ø B
4" C
H W
R (E
4"
C H
W S
(E
5" Ø SA
6" x 10" RA
4" Ø RA
OS
OS
OS
OS
DP2
12"ø A
14"ø B
(TYP OF 5)
14" Ø RA
14" Ø RA
14" Ø RA
14" Ø RA
14" Ø RA
14"ø B
(TYP OF 5)
14"x10" EA
14"x10" EA
" x
8"
R A
OSOS
DRAWING SHEET NOTES #
US Army Corps of Engineers ®
SHEET ID
U S A R M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
M A R K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
FI
LE
N U
M
BE
R
KEY PLAN
A-1
A-2
B-1
B-2
E-1
E-2
D-1
D-2
C-2C-1
F
G
H
PLAN NORTH
M-112
FI
R
ST
F
LO
O R M
EC
H A N
IC
A L
PL
A N A R
EA
G
FO
R T B
EN
N
IN
G , G
EO
R G
IA
SA
VA
N N A H D
IS
TR
IC
T
W . O G
LE
TH
O R
PE
A
VE
SA
VA
N N A H , G
EO
R G
IA
D . L
AW
D . H
AS
EN
KA
M
P
A.
H
AU
TM
AN
D . G
IB
BS
AU
G
U
ST
, 2
W
2H N
-2 2-
B-
READY TO ADVERTISE
B U
IL
D
IN
G H
EA
TI
N G , V
EN
TI
LA
TI
O N
A
IR
C O N D
IT
IO
N
IN
G (H
VA
C ) R
EP
A
IR
P
BLDG 3425
0 4' 8' 16' 1/8" = 1'-0"A1 FIRST FLOOR MECHANICAL PLAN - AREA G
1 UNLESS OTHERWISE NOTED, EXISTING HWS/R PIPE RUNOUTS ARE 1" IN
DIAMETER.
2 SPACE DIFFERENTIAL PRESSURE TRANSMITTER. LOCATE ABOVE CEILING.
3 14"x14" EA TO TO EF-G-1 ON ROOF 4 14"x14" EA TO TO EF-G-2 ON ROOF
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/1 4/
11 1
24 24
26 26
31 31
34 34
35 35
39 39
42 42
C.L
C.LD.L
D.L
F.L
F.L
J.L
J.L
K.L
K.L
M.L
M.L
P.L
P.L
S.L
S.L C.R
C.R D.R
D.R
F.R
F.R
J.R
J.R
K.R
K.R
M.R
M.R
P.R
P.R
S.R
S.R
/MATCHLINE A1 M-112
/MATCHLINE A1 M-105 /MATCHLINE A1 M-106
CORRIDOR
G102
C O
R R
ID
O
R H
CLASSROOM
H121
STORAGE
H122
STORAGE
H123
STORAGE
H124
ELECTRICAL
H125
STORAGE
H126
CLASSROOM
H128
STORAGE
H129
STORAGE
H130
STORAGE
H131
ELECTRICAL
H132
STORAGE
H133
ALCOVE
H134
CORRIDOR
H135
CLASSROOM
H136
STORAGE
H137
CLASSROOM
H138
STORAGE
H139
SICK CALL
H140
STORAGE
H141
CLASSROOM
H142
STORAGE
H143
STORAGE
H145
COMM
H135A
12" x 10" SA (E) 14" x 12" SA (E)
12" Ø SA (E)
10" Ø SA
10" Ø SA
32" x 12" SA (E) 17" x 10" SA (E)
VAV-H1-16
10" Ø SA
32" x 12" SA (E) 17" x 10" SA (E)
32" x 12" SA (E) 17" x 10" SA (E)
32" x 12" SA (E) 17" x 10" SA (E)
17" x 10" SA (E)32" x 12" SA (E)
10" Ø SA
10" Ø SA
10" Ø SA
32" x 12" SA (E) 17" x 10" SA (E)
10" Ø SA
20" x 16" SA (E)
20" x 12" SA (E) 12"
C H
W R
(E
3/4" HWS/R
3" HWS (E)
3" HWR (E)
4" CHWR (E)
3/4" HWS/R
3" HWR (E)
4" CHWR (E)
3" HWS (E)
3/4" HWR/S
4" CHWR (E)
3" HWR (E)
3" HWS (E)
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
VAV-H2-13
20" x 12" SA E
12" x 10" SA (E) 14" x 12" SA (E)
1" HWR (E)
1" HWS (E)
3/4" HWS/R
12" Ø SA E
10" Ø SA26" x 14" SA (E)
14" Ø SA E
14" Ø SA E
3/4" HWS/R
1" HWR (E)
1" HWS (E)
10" Ø SA
1" HWS (E)
1" HWR (E)
3/4" HWS/R
32" x 12" SA (E)17" x 10" SA (E)
18" x 16" SA (E)
17" x 10" SA (E) 32" x 12" SA (E) 10" Ø SA
3/4" HWS/R
" x
8"
S A
(E
)1" HWR (E)
1" HWS (E)
10" Ø SA
3/4" HWS/R
10" Ø SA
3/4" HWS/R
1" HWR (E)
1" HWS (E)
32" x 12" SA (E)17" x 10" SA (E)
26" x 18" SA (E)
1" HWS (E)
32" x 12" SA (E)17" x 10" SA (E)
1" HWS (E)
1" HWR (E)
1" HWS (E)
32" x 12" SA (E)17" x 10" SA (E)
4" CHWS (E)
4" CHWR (E)
3" HWR (E)
3" HWS (E)
VAV-H2-1
1" HWS (E)3/4" HWS/R
20" x 16" SA (E)
26" x 6" RA
26" x 6" RA
26" x 8" RA
34" x 10" RA
" x
" R
A
20" x 12" SA (E)
6" Ø SA
8" Ø SA (E)
18" x 16" SA
1" HWR (E)
1" HWS (E)3/4" HWR
3/4" HWS
3/4" HWS
3/4" HWR
CLASSROOM
H144
T
T T
T
10" Ø SA
T
T
T
T T
T
T
T T