W912HN-21-B-5004_DRAWINGS.pdf
PDF 22 MB Posted
- Solicitation number
- W912HN21B5004
About this file
This solicitation is for a firm fixed price contract to complete the removal and replacement of the existing roof system on the Powerhouse and Dam Pump Room buildings at Russell Dam in Elberton, Georgia. The contractor will remove the existing two-ply modified bitumen roof and install a new 90-mil EPDM single-ply roof system with a minimum R-value of R-30. The new roof will include associated flashings, insulation, sheet metal components and accessories to provide a watertight roof. An optional aluminum catwalk spanning the powerhouse roof is also included. The site visit will take place on August 19, 2021 and bids must be submitted in accordance with sealed bidding procedures under FAR Part 14. The contract will be awarded by the Department of the Army Corps of Engineers Savannah District.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BARBINA.SEAN.ERIC.1556536194 Digitally signed by BARBINA.SEAN.ERIC.1556536194 Date: 2021.07.27 08:21:35 -04'00'
FUNK.TROY.ALAN.1039429256 Digitally signed by FUNK.TROY.ALAN.1039429256 Date: 2021.07.27 15:27:34 -04'00'
HENDREN.TRACY.LEE.1229932868
2021.07.27 16:41:02 -04'00'
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
G (cont) ---------------------
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
N (cont) ---------------------
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
S (cont) --------------------
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DIDISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
0 GRID/COLUMN
LINE DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
W/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE
LEVEL
SHEET NUMBER WHERE
SECTION/DETAIL IS DRAWN
SHEET NUMBER WHERE
SECTION/DETAIL IS DRAWN
SHEET NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SIM
EXTERIOR ELEVATION
SHEET NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATORView Name1
1/8" = 1'-0"
MATCHLINE INDICATOR
VIEW TITLE BAR AND SCALE
1 / A-101
1 / A-102
REFERENCE
SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A-101
SIM
A101
Ref
R ef
Ref
R ef
8 6 2 0 8 164
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T- TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET SEQUENCE NUMBER
SHEET TYPE DESIGNATOR
DISCIPLINE DESIGNATOR
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endprm\Desktop\Rbr0115_RTA\Revit\FYXX_PNXXXXX_RBR DAM ROOF REPL_PROJ_R21.rvt
7/27/2021 7:22:09 AM
JU
LY
W
2H N
-2 1-
B-
P.
M
O R
AL
ES
P.
M
O R
AL
ES
S.
B
AR
BI
N A G
I0
.p df
N O
N E
GI002
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
M
C
TI
ER
N
AN
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
GENERAL NOTES:
G-1. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION
PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
TEMPORARY BRACING, GUYS, OR TIE-DOWNS.
G-2. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND CONSTRUCTION
AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES,
TECHNIQUES, SEQUENCES, LOADINGS AND SAFETY.
G-3. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS
FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN IMPACTED AREAS.
G-5. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
G-6. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
G-7. WHERE A DETAIL OR SECTION IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL LIKE OR
SIMILAR CONDITIONS EVEN THOUGH NOT SPECIFICALLY MARKED ON THE PLANS.
G-8. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
G-9. DO NOT SCALE THE DRAWINGS.
DESIGN LOAD CRITERIA:
D-2. LIVE LOADS: ROOF 20 PSF
CATWALK 40 PSF OR 300 LBS CONCENTRATED LOAD
ON 1 SQ FT
D-3. SNOW LOADS:
MINIMUM GROUND SNOW LOAD, Pg 10 PSF
D-4. WIND LOADS:
RISK CATEGORY III
BASIC WIND SPEED, V 116 MPH (ULTIMATE)
93 MPH (SERVICE)
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-5. SEISMIC LOADS:
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR, Ie 1.25 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.386
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.101
SITE CLASS D (ASSUMED)
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.38 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.16
SEISMIC DESIGN CATEGORY C
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC-FORCE RESISTING SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC
RESPONSE MODIFICATION FACTOR, R 3
SYSTEM OVERSTRENGTH FACTOR 3
DEFLECTION AMPLIFICATION FACTOR, Cd 3 SEISMIC RESPONSE COEFFICIENT, Cs 0.160
SEISMIC BASE SHEAR 1.47 KIPS
D-6. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
ANTI-TERRORISM/FORCE PROTECTION IS NOT REQUIRED FOR THIS FACILITY BASED ON THE INTENDED
OCCUPANCY AND DISTANCE TO CONTROLLED PERIMETER.
DESIGN CODE NOTES:
D-1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND
SPECIFICATIONS:
A. IBC 2018, INTERNATIONAL BUILDING CODE
B. IEBC 2018, INTERNATIONAL EXISTING BUILDING CODE
C. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
D. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
E. TMS 402-16, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
F. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
G. AISI S100-12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED
STEEL STRUCTURAL MEMBERS.
H. AWS, AMERICAN WELDING SOCIETY, STRUCTURAL WELDING CODE
I. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK, FORM DECK, &
ROOF DECK
J. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS (01 OCT 2020)
K. UFC 3-301-01, STRUCTURAL ENGINEERING, (01 OCT 2019)
L. UFC 4-010-01, DOD MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDINGS, (19 AUG 2020)
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_STRUCT_R21_k6enxmdz.rvt
7/27/2021 9:11:06 AM
JU
LY
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
N O
N E
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AFF ABOVE FINISHED FLOOR
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BCX BOTTOM CHORD EXTENSION
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CFS COLD-FORMED STEEL
CJ CONTRACTION JOINT
CL CENTER LINE
CLR CLEAR
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DEG DEGREE
DIA DIAMETER
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOD EDGE OF DECK
EOS EDGE OF SLAB
ES EACH SIDE
EQ EQUAL
EW EACH WAY
FF FINISHED FLOOR
FTG FOOTING
GA GAGE
GALV GALVANIZED
HGT HEIGHT
HORIZ HORIZONTAL
IS ISOLATION JOINT
JS JOIST SEAT
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MNFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SOG SLAB ON GRADE
SPCG SPACING
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF SLAB
TR TENSION REINFORCEMENT
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
STRUCTURAL ABBREVIATIONS
SLOPE DIRECTION
INDICATES ELEVATION REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
SLAB DEPRESSION
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
BRICK WALL
CONCRETE ELEMENT
EARTH FILL
GROUT
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
STRUCTURAL LEGEND
1' 1 2
ROOF ZONES
1. GROSS WIND PRESSURES SHOWN ABOVE ARE PREDICATED ON ULTIMATE WIND SPEED.
2. EDGE ZONES: 'a' = 7'-10"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LRFD LOAD COMBINATIONS SPECIFIED IN
SECTIONS 2.3 AND 2.4 OF ASCE 7-16.
4. POSITIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING TOWARDS THE COMPONENT AND
CLADDING SURFACES.
5. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING AWAY FROM THE COMPONENT AND
CLADDING SURFACES.
6. USE ZONE 3 PRESSURES FOR WIND ON THE PUMPHOUSE ROOF.
0.6h 0.6h
COMPONENT AND CLADDING WIND PRESSURES
EFFECTIVE WIND
AREA
ROOF ZONES
1'
10 SF
1 2
+16 / -35
+16 / -35
+16 / -35
0.
6h
0.6h
20 SF
50 SF
OVERHANG ZONES
1', 1 2
-60
-59
-58
+16 / -35100 SF -57
+16 / -30200 SF -49
+16 / -24500 SF -38
+16 / -60
+16 / -56
+16 / -51
+16 / -47
+16 / -43
+16 / -38
+16 / -79
+16 / -74
+16 / -67
+16 / -62
+16 / -57
+16 / -50
+16 / -107
+16 / -97
+16 / -84
+16 / -74
+16 / -64
+16 / -50
-79
-72
-63
-57
-50
-41
-107
-96
-80
-68
-57
-41
(T
YP
0.
2h
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_STRUCT_R21_k6enxmdz.rvt
7/27/2021 9:11:08 AM
JU
LY
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
N O
N E
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOT TO SCALE
COMPONENT AND CLADDING WIND PRESSURES1
1 2 3 4 5 5.5 6 7 8 9 9.5 10 11 12 13 13.5 14 15 16 17 17.5 18 19 20 21 21.5 22
H
R
PO
W
ER
PL
A N T
36' - 0" 20' - 11" 20' - 11" 20' - 11" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6"
ERECTION BAY
100' - 0"
BAY 1
71' - 0"
BAY 2
71' - 0"
BAY 3
71' - 0"
BAY 4
71' - 0"
APPROXIMATE LOCATION
OF WALKWAY COLUMNS BY
CONTRACTOR
WALKWAY BY
CONTRACTOR. SEE ARCH.
PROVIDE 2" GAP IN WALKWAY
WITH SLIDING COVER PLATE
TYP AT ALL EXPANSION JOINTS
EFEFEFEFEF
RTURTURTURTURTU
R H
EF
EF
EF
RD RD
RDRD RD RD RD RD RD RD RD RD RD
RDRDRDRDRDRDRDRDRDRDRD
RL
SAT
VTR
VTR
EL
RL RL RL RL RL
GUARDRAIL, SEE ARCH
S-301
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
NORTH ARROW
PLAN NORTH
GENERAL SHEET NOTES
C:\Users\k6enxmdz\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_STRUCT_R21_k6enxmdz.rvt
7/27/2021 9:11:11 AM
JU
LY
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
BA
R
BI
N A
N O
N E
S-101
PO
W
ER
PL
AN
T
R O
O F
PL
AN
W
ES
T
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
1/16" = 1'-0"
POWERPLANT ROOF PLAN - WEST1 16 12 4 0 16 328
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS, SEE S-001 AND S-002.
2. COORDINATE ALL DIMENSIONS, ELEVATIONS, OPENINGS AND PENETRATIONS
WITH ARCHITECTURAL DRAWINGS.
3. SEE ARCHITECTURAL DRAWINGS FOR DEMOLITION OF ITEMS.
4. SEE ARCHITECTURAL DRAWINGS FOR NEW ROOF DETAILS AND FOR EXTENTS OF
WORK IN VARIOUS OPTIONS.
5. SEE ARCHITECTURAL DRAWINGS FOR EXTENTS OF NON-PENETRATING
GUARDRAILS.
6. FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTED WORKING.
M
AR
K D
ES
C
R
IP
TI
O
N D
21 21.5 22 23 24 25 26 26.5 27
R
2928 30 31 31.5 32 33 34 35 36 36.5 37 38 39 40 41 42
2' - 6" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 2' - 6" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 2' - 6" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 2' - 6" 17' - 3" 17' - 3" 17' - 3" 17' - 3" 22' - 9"
BAY 5
80' - 0"
BAY 6
80' - 0"
BAY 7
80' - 0"
BAY 8
93' - 0"
APPROXIMATE LOCATION
OF WALKWAY COLUMNS BY
CONTRACTOR
WALKWAY BY
CONTRACTOR. SEE ARCH
PROVIDE 2" GAP IN WALKWAY
WITH SLIDING COVER PLATE
TYP AT ALL EXPANSION JOINTS
EF
RTU
EFEF
RTURTURTU
RD RD RD RD RD RD RD RD RD
RDRDRDRDRDRDRDRDRD
EF
RL RL RL RL
GUARDRAIL, SEE ARCH
S-301
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
NORTH ARROW
PLAN NORTH
GENERAL SHEET NOTES
C:\Users\k6enxmdz\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_STRUCT_R21_k6enxmdz.rvt
7/27/2021 9:11:16 AM
JU
LY
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
BA
R
BI
N A
N O
N E
S-102
PO
W
ER
PL
AN
T
R O
O F
PL
AN
EA
ST
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
1/16" = 1'-0"
POWERPLANT ROOF PLAN - EAST1
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS, SEE S-001 AND S-002.
2. COORDINATE ALL DIMENSIONS, ELEVATIONS, OPENINGS AND PENETRATIONS
WITH ARCHITECTURAL DRAWINGS.
3. SEE ARCHITECTURAL DRAWINGS FOR DEMOLITION OF ITEMS.
4. SEE ARCHITECTURAL DRAWINGS FOR NEW ROOF DETAILS AND FOR EXTENTS OF
WORK IN VARIOUS OPTIONS.
5. SEE ARCHITECTURAL DRAWINGS FOR EXTENTS OF NON-PENETRATING
GUARDRAILS.
6. FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTED WORKING.
16 12 4 0 16 328
M
AR
K D
ES
C
R
IP
TI
O
N D
ALUMINUM WALKWAY STRINGER BY CONTRACTOR
ALUMINUM WALKWAY PURLIN BY CONTRACTOR
ALUMINUM SERRATED GRATING OR SAFETY
PLATE BY CONTRACTOR
EXISTING CONCRETE ROOF PANEL
SECTION IS CONCEPTUAL. ACTUAL DESIGN OF
ALL ITEMS INCLUDING BRACING AND
CONNECTIONS BY CONTRACTOR. BRACING
AND CONNECTIONS NOT SHOWN. STAIRS ARE
NOT SHOWN BUT SHALL BE PROVIDED AT
LOCATIONS SHOWN ON THE ARCHITECTURAL
DRAWINGS.
ROUND ALUMINUM POSTS LOCATED
OVER EXISTING RIGID FRAMES.
BASE PLATE AND ANCHORAGE TO
CONCRETE PLANKS BY
CONTRACTOR
ALUMINUM GUARDRAIL POSTS.
DESIGN OF POSTS AND
CONNECTIONS BY CONTRACTOR
ROOF MATERIAL, SEE ARCH
BOTTOM OF WALKWAY SHALL BE A
MINIMUM OF 6" ABOVE
INTERMEDIATE PARAPETS
3'
6"
1'
9"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_STRUCT_R21_k6enxmdz.rvt
7/27/2021 9:11:18 AM
JU
LY
W
2H N
-2 1-
B-
M . Z
AI
TZ
M . Z
AI
TZ
S.
B
AR
BI
N A
N O
N E
S-301
SE
C
TI
O
N S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
EL
BE
R
TO
N , G
EO
R
G
IA
R U
SS
EL
L D
AM
P
O W
ER
PL
AN
T
R O
O F
R
EP
LA
C
EM
EN
T
FY
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
1 1/2" = 1'-0"
CONCEPTUAL WALKWAY SECTION1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
1 0 1
1 9.5 13.5 17.5 21.5 26.5 31.5 36.5 425.5
R
2 3 4 7 8 11 12 15 16 19 20 23 24 25 28 29 30 33 34 35 38 39 40 41
1. APPLICABLE CODES AND STANDARDS:
A. UFC 1-200-01 DOD BUILDING CODE, CHANGE 1, 01 OCTOBER 2020
B. UFC 3-101-01 ARCHITECTURE, CHANGE 1, 05 JANUARY 2021
C. UFC 3-110-03 ROOFING, CHANGE 5, 12 JUNE 2020
D. IBC INTERNATIONAL BUILDING CODE, 2018
2. ROOF AND WALL PENETRATIONS/FLASHING SHALL CONFORM TO ACCEPTED
ROOFING PRACTICES AS DESCRIBED AND DETAILED IN THE CURRENT
EDITION OF THE NRCA ROOFING AND WATERPROOFING MANUALS & THE
SMACNA ARCHITECTURAL SHEET METAL MANUAL.
3. COMPLETELY SEAL AROUND PENETRATIONS PER MANUFACTURER'S
RECOMMENDATIONS TO MAINTAIN AIR BARRIER / WEATHER TIGHT
CONDITIONS.
SHEET ID
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
D
C
B
A
C A
T E
G O
R Y
C O
D E
A N
S I D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endfjl\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_ARCH_R21_k6endfjl.rvt
7/27/2021 9:42:40 AM
J U
L Y
W H
N -2
-B
-5
F .L
IE
B
G O
T T
F .L
IE
B
G O
T T
S .B
A R
B
IN
A N
O N
E
A-001
O V
E R
A L L P
L A
N
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
E L B
E R
T O
N G
E O
R G
IA
R
U S
S E
L L D
A M
P O
W E
R P
L A
N T
R O
O F
R E
P L A
C E
M E
N T
F Y
P .S
U L L
IV
A N
READY TO ADVERTISE (RTA)
PUMP HOUSE
ROOF
POWERPLANT
ROOF
1" = 40'-0"
POWERPLANT - OVERALL ROOF PLAN2
A-101 A-102
NOT TO SCALE
RUSSELL DAM AERIAL VIEW
PLAN NORTH
PLAN NORTH
GENERAL SHEET NOTES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A-101 A-102
40 30 10 0 40 8020
1 9.5 13.5 17.5 21.5
10' - 1 1/2"
ERECTION BAY
89' - 10 1/2"
BAY 1
71' - 0"
BAY 2
71' - 0"
BAY 3
71' - 0"
BAY 4
71' - 0"
5.5
H
R
V
IS
IT
O
R C
E N
T E
R
P O
W E
R P
L A
N T
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
EFEFEFEFEF
RTURTURTURTURTU
R H
EF
EF
EF
RD RD
RDRD RD RD RD RD RD RD RD RD RD
RDRDRDRDRDRDRDRDRDRDRD
RL
RL RL RL RL RL
SAT
10 10 10 10 10
A-501
A-501
14 14
VTR
VTR
EL
A-501
A-501
A-501
A-501
LINE OF SLOPED STANDING SEAM ROOF TO
REMAIN. PROTECT AS REQUIRED
131313
1515 15
2' - 6"36' - 0" 20' - 11" 20' - 11" 20' - 11" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10" 2' - 6" 22' - 10" 22' - 10" 22' - 10"
1111111111
11 11 11 11 16 17
16 17
THE EXISTING ROOFTOP UNITS (1-9) ARE MCQUAY-PERFEX INC. MODEL
NUMBER RDS800BY. EACH OF THE UNITS WEIGH APPROXIMATELY 4600
POUNDS INCLUDING ALL ACCESSORIES. EACH RTU HAS FOUR (4) TOTAL
LIFT POINTS THAT ARE LOCATED AT EACH CORNER OF THE UNIT NEAR THE
BOTTOM. THE WIRING FOR THE 480 DISCONNECT RUNS INTERNAL TO THE
UNIT AND THERE IS NO EXTERNAL CONDUIT GOING THROUGH THE ROOF
TO THE DISCONNECT BOX.
LEGEND
SLOPE DIRECTION
RD ROOF DRAIN
EF EXHAUST FAN
RTU ROOFTOP UNIT
RH ROOF HATCH
SAT SATELLITE DISH
RL ROOF PARAPET LADDER
VTR VENT THRU ROOF
EL EMERGENCY STROBE LIGHT
1. APPLICABLE CODES AND STANDARDS:
A. UFC 1-200-01 DOD BUILDING CODE, CHANGE 1, 01 OCTOBER 2020
B. UFC 3-101-01 ARCHITECTURE, CHANGE 1, 05 JANUARY 2021
C. UFC 3-110-03 ROOFING, CHANGE 5, 12 JUNE 2020
D. IBC INTERNATIONAL BUILDING CODE, 2018
2. ROOF AND WALL PENETRATIONS/FLASHING SHALL CONFORM TO ACCEPTED
ROOFING PRACTICES AS DESCRIBED AND DETAILED IN THE CURRENT
EDITION OF THE NRCA ROOFING AND WATERPROOFING MANUALS & THE
SMACNA ARCHITECTURAL SHEET METAL MANUAL.
3. COMPLETELY SEAL AROUND PENETRATIONS PER MANUFACTURER'S
RECOMMENDATIONS TO MAINTAIN AIR BARRIER / WEATHER TIGHT
CONDITIONS.
DEMOLITION NOTES
1. ALL EXISTING ROOFING MATERIALS ARE TO BE REMOVED
COMPLETE DOWN TO THE STRUCTURAL CONCRETE ROOF DECK.
THIS INCLUDES ALL LAYERS OF EXISTING BITUMINOUS ROOFING,
ROOF INSULATION, ROOF FLASHINGS, MEMBRANE AND
FLASHINGS/MEMBRANE ON PARAPETS, ETC. REFER TO DETAIL
3/A-501
2. ALL EXISTING RTU'S, EXHAUST FANS, ROOF PARAPET LADDERS,
SATELLITE DISH AND ROOF HATCH WILL ALL REQUIRE REMOVAL.
SALVAGE FOR REINSTALLATION INTO NEW WORK.
3. REMOVE EXISTING ROOF DRAINS AND SALVAGE FOR
REINSTALLATION INTO NEW WORK.
SCOPE NOTES
1. NEW ROOF SYSTEM TO BE 90 MIL FULLY ADHERED WHITE EPDM ON
THE ROOF AND 60 MIL FULLY ADHERED WHITE EPDM ON THE
VERTICAL AND HORIZONTAL PORTIONS OF THE PARAPETS. NEW
ROOF INSULATION TO BE R30 MINIMUM. ROOF INSULATION TO BE
POLYISOCYANURATE WITH A 1/2" COVERBOARD.
2. ALL EXISTING RTU'S, EXHAUST FANS, ROOF PARAPET LADDERS,
SATELLITE DISH AND ROOF HATCH WILL ALL BE REINSTALLED ON
NEW CURBS TO COORDINATE WITH NEW INCREASED ROOF
INSULATION THICKNESS.
3. EXTEND ROOF DRAIN LINES AS REQUIRED TO COORDINATE WITH
NEW ROOF THICKNESS. REINSTALL EXISTING ROOF DRAINS.
4. DISCONNECT AND MAKE SAFE ALL ELECTRICAL FEEDERS, BRANCH
CIRCUITS AND OTHER CABLES TO ALL EQUIPMENT BEING REMOVED
AND REINSTALLED AS PART OF THE ROOF REPLACEMENT.
EXTENSION OF CONDUCTORS AND RACEWAYS AND CABLES
REQUIRED FOR RE-CONNECTION AFTER RE-INSTALLATION OF
EQUIPMENT SHALL BE MADE IN ACCORDANCE WITH MATERIAL,
WIRING METHOD AND WORKMANSHIP REQUIREMENTS OF NFPA 70,
NATIONAL ELECTRICAL CODE, 2020 EDITION. SHEET ID
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
D
C
B
A
C A
T E
G O
R Y
C O
D E
A N
S I D
E
F
G
2 3 4 5 6 7 8 9 10
NORTH ARROW
PLAN NORTH
GENERAL SHEET NOTES
C:\Users\k6endfjl\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_ARCH_R21_k6endfjl.rvt
8/30/2021 9:10:44 AM
J U
L Y
W H
N -2
-B
-5
F .L
IE
B
G O
T T
F .L
IE
B
G O
T T
S .B
A R
B
IN
A N
O N
E
A-101
P O
W E
R P
L A
N T
R O
O F
P L A
N
W E
S T
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
E L B
E R
T O
N G
E O
R G
IA
R
U S
S E
L L D
A M
P O
W E
R P
L A
N T
R O
O F
R E
P L A
C E
M E
N T
F Y
P .S
U L L
IV
A N
READY TO ADVERTISE (RTA)
1/16" = 1'-0"
POWERPLANT ROOF PLAN - WEST1 16 12 4 0 16 328
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
A
U G
KEYNOTES
10 HIGH POINT OF EXISTING SLOPED CONCRETE ROOF STRUCTURE TO
REMAIN (SLOPE IS 1/4" PER FOOT ACCORDING TO EXISTING
DOCUMENTS)
11 TAPERED ROOF INSULATION: 1/4" SLOPE MIN.
12 42" HIGH NON-PENETRATING SAFETY GUARDRAIL SYSTEM. SET BASES
ON ROOF WALKPADS TO PROVIDE ADDITIONAL PROTECTION TO THE
EPDM ROOF MEMBRANE.
13 GREY POCHE INDICATES LOCATIONS OF WALK PADS.
14 REMOVE EXISTING PREFINISHED METAL COPING TO INSTALL NEW EPDM
ROOF MEMBRANE. INSTALL NEW COPING ONCE NEW EPDM MEMBRANE
HAS BEEN INSTALLED. REFER TO DETAIL 5/A-501.
15 NON-PENETRATING SAFETY GUARDRAIL RETURN.
16 OPTION 1: ALUMINUM CATWALK SYSTEM. 48" WIDE CLEAR WIDTH
BETWEEN 42" HIGH GUARDRAILS. REFER TO STRUCTURAL FOR
ADDITIONAL INFORMATION.
17 OPTION 1: ALUMINUM CATWALK SYSTEM STEPS DOWN TO ROOF WITH
HANDRAILS. STEPS TO HAVE 12" TREADS AND 7" MAX RISE.
18 TAPERED INSULATION CRICKET: 1/8" SLOPE.
19 42" GALVANIZED METAL GUARDRAIL
20 20" WIDE GALVANIZED METAL LADDER WITH SAFETY CAGE.
COORDINATE LOCATION WITH EXISTING CONDUIT ON WALL BELOW.
21 1/4" PER FOOT (MIN) TAPERED INSULATION
21.5 26.5 31.5 36.5 42
BAY 5
80' - 0"
BAY 6
80' - 0"
BAY 7
80' - 0"
BAY 8
93' - 0"
H
R
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
EF
RTU
EFEF
RTURTURTU
RD RD RD RD RD RD RD RD RD
RDRD
RDRDRDRDRDRDRD
RL RL RL RL
10 10 10 10
A-501
A-501
14 14
A-501
A-501
LINE OF SLOPED STANDING SEAM ROOF TO
REMAIN. PROTECT AS REQUIRED
EF
13 13 1313
2' - 6" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 2' - 6" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 20' - 7 1/2" 1' - 3" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 19' - 4 1/2" 2' - 6" 17' - 3" 17' - 3" 17' - 3" 17' - 3" 22' - 9"
1111 11 11
11 11 11
16 17 1716 17
THE EXISTING ROOFTOP UNITS (1-9) ARE MCQUAY-PERFEX INC. MODEL
NUMBER RDS800BY. EACH OF THE UNITS WEIGH APPROXIMATELY 4600
POUNDS INCLUDING ALL ACCESSORIES. EACH RTU HAS FOUR (4) TOTAL
LIFT POINTS THAT ARE LOCATED AT EACH CORNER OF THE UNIT NEAR THE
BOTTOM. THE WIRING FOR THE 480 DISCONNECT RUNS INTERNAL TO THE
UNIT AND THERE IS NO EXTERNAL CONDUIT GOING THROUGH THE ROOF
TO THE DISCONNECT BOX.
LEGEND
SLOPE DIRECTION
RD ROOF DRAIN
EF EXHAUST FAN
RTU ROOFTOP UNIT
RH ROOF HATCH
SAT SATELLITE DISH
RL ROOF PARAPET LADDER
VTR VENT THRU ROOF
EL EMERGENCY STROBE LIGHT
1. APPLICABLE CODES AND STANDARDS:
A. UFC 1-200-01 DOD BUILDING CODE, CHANGE 1, 01 OCTOBER 2020
B. UFC 3-101-01 ARCHITECTURE, CHANGE 1, 05 JANUARY 2021
C. UFC 3-110-03 ROOFING, CHANGE 5, 12 JUNE 2020
D. IBC INTERNATIONAL BUILDING CODE, 2018
2. ROOF AND WALL PENETRATIONS/FLASHING SHALL CONFORM TO ACCEPTED
ROOFING PRACTICES AS DESCRIBED AND DETAILED IN THE CURRENT
EDITION OF THE NRCA ROOFING AND WATERPROOFING MANUALS & THE
SMACNA ARCHITECTURAL SHEET METAL MANUAL.
3. COMPLETELY SEAL AROUND PENETRATIONS PER MANUFACTURER'S
RECOMMENDATIONS TO MAINTAIN AIR BARRIER / WEATHER TIGHT
CONDITIONS.
DEMOLITION NOTES
1. ALL EXISTING ROOFING MATERIALS ARE TO BE REMOVED
COMPLETE DOWN TO THE STRUCTURAL CONCRETE ROOF DECK.
THIS INCLUDES ALL LAYERS OF EXISTING BITUMINOUS ROOFING,
ROOF INSULATION, ROOF FLASHINGS, MEMBRANE AND
FLASHINGS/MEMBRANE ON PARAPETS, ETC. REFER TO DETAIL
3/A-501
2. ALL EXISTING RTU'S, EXHAUST FANS, ROOF PARAPET LADDERS,
SATELLITE DISH AND ROOF HATCH WILL ALL REQUIRE REMOVAL.
SALVAGE FOR REINSTALLATION INTO NEW WORK.
3. REMOVE EXISTING ROOF DRAINS AND SALVAGE FOR
REINSTALLATION INTO NEW WORK.
SCOPE NOTES
1. NEW ROOF SYSTEM TO BE 90 MIL FULLY ADHERED WHITE EPDM ON
THE ROOF AND 60 MIL FULLY ADHERED WHITE EPDM ON THE
VERTICAL AND HORIZONTAL PORTIONS OF THE PARAPETS. NEW
ROOF INSULATION TO BE R30 MINIMUM. ROOF INSULATION TO BE
POLYISOCYANURATE WITH A 1/2" COVERBOARD.
2. ALL EXISTING RTU'S, EXHAUST FANS, ROOF PARAPET LADDERS,
SATELLITE DISH AND ROOF HATCH WILL ALL BE REINSTALLED ON
NEW CURBS TO COORDINATE WITH NEW INCREASED ROOF
INSULATION THICKNESS.
3. EXTEND ROOF DRAIN LINES AS REQUIRED TO COORDINATE WITH
NEW ROOF THICKNESS. REINSTALL EXISTING ROOF DRAINS.
4. DISCONNECT AND MAKE SAFE ALL ELECTRICAL FEEDERS, BRANCH
CIRCUITS AND OTHER CABLES TO ALL EQUIPMENT BEING REMOVED
AND REINSTALLED AS PART OF THE ROOF REPLACEMENT.
EXTENSION OF CONDUCTORS AND RACEWAYS AND CABLES
REQUIRED FOR RE-CONNECTION AFTER RE-INSTALLATION OF
EQUIPMENT SHALL BE MADE IN ACCORDANCE WITH MATERIAL,
WIRING METHOD AND WORKMANSHIP REQUIREMENTS OF NFPA 70,
NATIONAL ELECTRICAL CODE, 2020 EDITION.
EF
RD
A-102
EXISTING CONCRETE
ROOF DECK
VAPOR BARRIER
60 MIL FULLY ADHERED
EPDM (WHITE) TO WRAP
TOP OF PARAPET
PREFINISHED METAL
COPING TO MATCH EXISTING
ROOF COLOR
90 MIL FULLY
ADHERED EPDM
(WHITE) OVER 1/2"
COVER BOARD 1
A B
O V
E R
O O
F S
U R
F A
C E
1 1/2" DIA. GALVANIZED PIPE
GUARDRAIL
EXISTING CONCRETE
WALL AND PARAPET
(4) STAINLESS STEEL 1/2"
DIA. WEDGE ANCHORS (4"
EMBED) PER BRACKET.
FINAL SIZE AND SPACING
BY CONTRACTOR.
GALVANIZED METAL
GUARDRAIL BRACKET.
4" GALVANIZED TOE KICK
SHEET ID
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
D
C
B
A
C A
T E
G O
R Y
C O
D E
A N
S I D
E
F
G
2 3 4 5 6 7 8 9 10
NORTH ARROW
PLAN NORTH
GENERAL SHEET NOTES
C:\Users\k6endfjl\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_ARCH_R21_k6endfjl.rvt
8/30/2021 9:10:47 AM
J U
L Y
W H
N -2
-B
-5
F .L
IE
B
G O
T T
F .L
IE
B
G O
T T
S .B
A R
B
IN
A N
O N
E
A-102
P O
W E
R P
L A
N T
R O
O F
P L A
N
E A
S T
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
E L B
E R
T O
N G
E O
R G
IA
R
U S
S E
L L D
A M
P O
W E
R P
L A
N T
R O
O F
R E
P L A
C E
M E
N T
F Y
P .S
U L L
IV
A N
READY TO ADVERTISE (RTA)
1/16" = 1'-0"
POWERPLANT ROOF PLAN - EAST1 16 12 4 0 16 328
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
A
U G
KEYNOTES
1/8" = 1'-0"
PUMP ROOM ROOF PLAN2 8 6 2 0 8 164
PUMP ROOM ROOF SCOPE
REMOVE EXISTING INSULATED BUILT-UP ROOF SYSTEM COMPLETE DOWN TO
CONCRETE DECK. REMOVE EXISTING WALL, PARAPET AND CURB FLASHINGS.
REMOVE EXISTING ROOFING ON ALL PARAPET WALLS.
INSTALL NEW 90 MIL FULLY ADHERED WHITE EPDM ON ½” HD COVER BOARD
OVER POLYISOCYANURATE INSULATION, SLOPE TO EXISTING DRAIN. 60 MIL
FULLY ADHERED WHITE EPDM ON PARAPET WALLS AND OVER TOP OF PARAPET.
NEW PRE-FINISHED METAL WALL FLASHING AND COPINGS ON PARAPET WALLS,
COLOR TO MATCH EXISTING.
1" = 1'-0"
PUMP ROOM PARAPET3 1 0 1 21/2
10 HIGH POINT OF EXISTING SLOPED CONCRETE ROOF STRUCTURE TO
REMAIN (SLOPE IS 1/4" PER FOOT ACCORDING TO EXISTING
DOCUMENTS)
11 TAPERED ROOF INSULATION: 1/4" SLOPE MIN.
12 42" HIGH NON-PENETRATING SAFETY GUARDRAIL SYSTEM. SET BASES
ON ROOF WALKPADS TO PROVIDE ADDITIONAL PROTECTION TO THE
EPDM ROOF MEMBRANE.
13 GREY POCHE INDICATES LOCATIONS OF WALK PADS.
14 REMOVE EXISTING PREFINISHED METAL COPING TO INSTALL NEW EPDM
ROOF MEMBRANE. INSTALL NEW COPING ONCE NEW EPDM MEMBRANE
HAS BEEN INSTALLED. REFER TO DETAIL 5/A-501.
15 NON-PENETRATING SAFETY GUARDRAIL RETURN.
16 OPTION 1: ALUMINUM CATWALK SYSTEM. 48" WIDE CLEAR WIDTH
BETWEEN 42" HIGH GUARDRAILS. REFER TO STRUCTURAL FOR
ADDITIONAL INFORMATION.
17 OPTION 1: ALUMINUM CATWALK SYSTEM STEPS DOWN TO ROOF WITH
HANDRAILS. STEPS TO HAVE 12" TREADS AND 7" MAX RISE.
18 TAPERED INSULATION CRICKET: 1/8" SLOPE.
19 42" GALVANIZED METAL GUARDRAIL
20 20" WIDE GALVANIZED METAL LADDER WITH SAFETY CAGE.
COORDINATE LOCATION WITH EXISTING CONDUIT ON WALL BELOW.
21 1/4" PER FOOT (MIN) TAPERED INSULATION
60 MIL FULLY ADHERED EPDM
(WHITE) ON TOP OF PARAPET
1/2" HEAVY DUTY COVER BOARD
60 MIL FULLY ADHERED
EPDM (WHITE)
5/8" GLASS MAT SHEATHING
3 5/8" METAL RUNNER
ANCHORED TO EXISTING
CONCRETE DECK
90 MIL FULLY ADHERED
EPDM (WHITE) OVER 1/2"
COVER BOARD
EXISTING 3/16" ALUMINUM
PLATE COPING
EXISTING CONCRETE
PARAPET WALL
EXISTING 1/4" CONTINUOUS
'Z' CLOSURE
TAPERED POLYISOCYANURATE
ROOF INSULATION WHERE
OCCURS
POLYISOCYANURATE ROOF
INSULATION (R-30 MIN.)VAPOR BARRIER
EXISTING CONCRETE
ROOF DECK
60 MIL FULLY ADHERED EPDM
(WHITE) ON TOP OF PARAPET
1/2" HEAVY DUTY COVER
BOARD
60 MIL FULLY ADHERED
EPDM (WHITE)
5/8" GLASS MAT SHEATHING
3 5/8" METAL RUNNER
ANCHORED TO EXISTING
CONCRETE DECK
90 MIL FULLY ADHERED
EPDM (WHITE) OVER
1/2" COVER BOARD
EXISTING 3/16" ALUMINUM
PLATE COPING
EXISTING CONCRETE
PARAPET WALL
EXISTING 1/4" CONTINUOUS
'Z' CLOSURE
TAPERED
POLYISOCYANURATE ROOF
INSULATION WHERE
OCCURS
POLYISOCYANURATE ROOF
INSULATION (R-30 MIN.)
EXISTING CONCRETE
ROOF DECK
VAPOR BARRIER
COMPRESSIBLE TUBE
REMOVE EXISTING EPDM
MEMBRANE, FIBERBOARD
AND INSULATION FROM
EXISTING ALUM. PLATE
COPING AND ANY OTHER
RELATED ITEMS COMPLETE
REMOVE EXISTING FLASHING
COMPLETE
REMOVE EXISTING ROOF
DOWN TO EXISTING
CONCRETE ROOF DECK
AND PREPARE SURFACES
TO RECEIVE NEW ROOF
SYSTEM
EXISTING 3/16" ALUMINUM
PLATE COPING TO
REMAIN
EXISTING CONCRETE
PARAPET WALL TO
REMAIN
EXISTING 1/4" CONTINUOUS
'Z' CLOSURE TO REMAIN
EXISTING CONCRETE ROOF
DECK TO REMAIN
REMOVE EXISTING
TERMINATION BAR
COMPLETE
60 MIL FULLY ADHERED EPDM
(WHITE) ON TOP OF PARAPET
EXISTING CONCRETE
PARAPET WALL
1/2" HEAVY DUTY COVER
BOARD
EXISTING 3/16" ALUMINUM
PLATE COPING
PRE-FINISHED METAL DRIP
EDGE COPING TO MATCH
EXISTING
REMOVE AND REPLACE
BACKER ROD AND SEALANT
IN THIS JOINT AROUND
BUILDING
1/2" HEAVY DUTY COVER
BOARD
EXISTING 3/16" ALUMINUM
PLATE COPING
REFER TO DETAIL 1/A-501
FOR TYPICAL NOTES
EXISTING SLOPE
60 MIL FULLY ADHERED EPDM
(WHITE) ON TOP OF PARAPET
REFER TO DETAIL 1/A-501
FOR TYPICAL NOTES
60 MIL FULLY ADHERED
EPDM (WHITE) TO WRAP
TOP OF PARAPET
EXISTING CONCRETE
PARAPET WALL
1/2" HEAVY DUTY COVER
BOARD
EXISTING 3/16" ALUMINUM
PLATE COPING
PREFINISHED METAL
COPING TO MATCH EXISTING
ROOF COLOR
EXISTING SLOPED
STANDING SEAM ROOF TO
REMAIN
CANT STRIP
EXISTING SLOPE
SHEET ID
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
D
C
B
A
C A
T E
G O
R Y
C O
D E
A N
S I D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endfjl\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_ARCH_R21_k6endfjl.rvt
7/27/2021 9:42:43 AM
J U
L Y
W H
N -2
-B
-5
F .L
IE
B
G O
T T
F .L
IE
B
G O
T T
S .B
A R
B
IN
A N
O N
E
A-501
R O
O F
D E
T A
IL
S
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
E L B
E R
T O
N G
E O
R G
IA
R
U S
S E
L L D
A M
P O
W E
R P
L A
N T
R O
O F
R E
P L A
C E
M E
N T
F Y
P .S
U L L
IV
A N
READY TO ADVERTISE (RTA)
1 1/2" = 1'-0"
ROOF DETAIL - TYPICAL PARAPET1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1 1/2" = 1'-0"
ROOF DETAIL - TYPICAL EXPANSION JOINT2
1 0 1 1 0 1
1 1/2" = 1'-0"
ROOF DETAIL - TYPICAL PARAPET DEMOLITION3
1 1/2" = 1'-0"
ROOF DETAIL - TYPICAL PARAPET COPING 14
1 0 1 1 0 1 1 0 1
1 1/2" = 1'-0"
ROOF DETAIL - TYPICAL PARAPET @ SLOPED ROOF5 1 0 1
SHEET ID
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
D
C
B
A
C A
T E
G O
R Y
C O
D E
A N
S I D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endfjl\Documents\FYXX_PNXXXXX_RBR DAM ROOF REPL_ARCH_R21_k6endfjl.rvt
7/27/2021 9:42:44 AM
J U
L Y
W H
N -2
-B
-5
F .L
IE
B
G O
T T
F .L
IE
B
G O
T T
S .B
A R
B
IN
A N
O N
E
A-502
R E
F E
R E
N C
E P
H O
T O
S
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
E L B
E R
T O
N G
E O
R G
IA
R
U S
S E
L L D
A M
P O
W E
R P
L A
N T
R O
O F
R E
P L A
C E
M E
N T
F Y
P .S
U L L
IV
A N
READY TO ADVERTISE (RTA)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
IMAGE 1:TYPICAL RTU AND EXHAUST FAN IMAGE 2: ROOF HATCH, ROOF DRAIN AND EMERGENCY STROBE LIGHT IMAGE 3: TYPICAL ROOF PARAPET AND ROOF DRAIN IMAGE 4: WALK PADS ON PARAPET, EXHAUST FANS AND ROOF DRAIN OVER VISITOR'S CENTER
IMAGE 5: TYPICAL ROOF PARAPET LADDER IMAGE 6: SOUTHEAST CORNER IMAGE 7: TYPICAL RTU AND ROOF PARAPET LADDER WITH SATELLITE DISH IMAGE 8: PUMP ROOM ROOF
IMAGE 9:WALKPADS ON NORTH PARAPET IMAGE 10: WALKPADS AT SOUTH PARAPET OVER VISITOR'S CENTER
IMAGE 11: TYPICAL ROOF DRAIN IMAGE 12: SOUTHEAST PARAPET AT VISITOR'S CENTER IMAGE 13: PARAPET COPING AT NORTH PARAPET IMAGE 14: PARAPET COPING AT SOUTH PARAPET
| GI001 COVER SHEET AND INDEX OF DRAWINGS |
| GI002 GENERAL NOTES, ABBREVIATIONS |
| S-001 GENERAL STRUCTURAL NOTES |
| S-002 GENERAL STRUCTURAL NOTES |
| S-101 POWERPLANT ROOF PLAN - WEST |
| S-102 POWERPLANT ROOF PLAN - EAST |
| S-301 SECTIONS |
| A-001 OVERALL PLAN |
| A-101 POWERPLANT ROOF PLAN - WEST |
| A-102 POWERPLANT ROOF PLAN - EAST |
| A-501 ROOF DETAILS |
| A-502 REFERENCE PHOTOS |
File details come from the government source that posted it. Updated .