B.08 - Drawing - W912HN21B5000_AMD 02.pdf
PDF 819 KB Posted
- Attached to
- Savannah Harbor DMCA 1N Dike Raising Federal contract opportunity
- Solicitation number
- W912HN21B5000
About this file
This document package includes plans and specifications for a federal construction contract opportunity with the U.S. Army Corps of Engineers Savannah District. The solicitation seeks construction services to raise the perimeter dike and cross dike at the Savannah Harbor DMCA 1N dredged material containment area in Chatham County, Georgia to uniform elevations of 33 feet and 31 feet MLLW respectively. Work includes clearing, earthwork, surveying, turf establishment, relocating two southeastern weirs and providing additional catwalks and weir risers on two weirs along the cross dike. Bidders must furnish personnel, transportation, equipment and materials to install and remove silt fence for erosion control, harvest earth materials for placement, maintain roadways, and apply herbicide. The 9,270 foot new dike centerline alignment and weir/outfall areas must be cleared. The contractor will be responsible for verifying all dimensions and elevations.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| C.04 Bid Abstract W912HN21B5000.pdf | ||
| C.04 Bid Opening Attendee List.pdf | ||
| B.08 AMD 02 Conformed Solicitation W912HN21B5000.pdf | ||
| B.08 AMD 02 Solicitation W912HN21B5000.pdf | ||
| B.08 AMD 01 Conformed Solicitation W912HN21B5000.pdf | ||
| B.08- Specs W912HN21B5000 _ Amd01.PDF | ||
| B.08 AMD 01 Solicitation W912HN21B5000.pdf | ||
| Savannah Harbor DMCA 1N Dike Raising W912HN21B5000 _ Site Visit 19Apr2021.pdf | ||
| B.08 - Specs W912HN21B5000.pdf | ||
| B.08 - Solicitation _ W912HN21B5000.pdf | ||
| B.08 - Drawings W912HN21B5000.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G E
N E
R A
L N
O T
E S
ACCORDANCE WITH THE REQUIREMENTS OF ACI 318.
OTHERWISE. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN
CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS NOTED
INDICATED, UNLESS NOTED OTHERWISE.
MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS
CONCRETE EXPOSED TO WEATHER
CONCRETE CAST AGAINST EARTH
3"
2"
1"
SLABS AND WALLS
1.
2.
3.
REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
TOLERANCES IN ACCORDANCE WITH ACI SP-66. SHOP FABRICATE
TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION
CONCRETE REINFORCING BARS SHALL BE DEFORMED BARS CONFORMING
CONCRETE DENSITY SHALL BE NORMAL WEIGHT.
COMPRESSIVE STRENGTH (f'c) OF 4,000 PSI.
CAST-IN-PLACE CONCRETE SHALL ATTAIN A MINIMUM 28-DAY
NOT BE ACCEPTED.
SPOOL TYPE. FLANGES WELDED BY A GUN ONTO NEW HDPE PIPE WILL
ALL FLANGES ON NEW HDPE PIPE MUST BE SHOP- MANUFACTURED
THE TIMBER PILES SHALL COMPLY WITH UFGS SPEC 31 62 19.
ASTM D3350, MINIMUM CELL CLASS 335434C.
POLYETHYLENE MATERIAL THAT MEETS THE REQUIREMENTS OF
PIPES, WEIR RISERS, AND BEARING PLATES SHALL BE HIGH DENSITY
THESE CONTRACT DRAWINGS, THE FORMER SHALL GOVERN.
COMPLY WITH UFGS SPECS 06 73 01. IN CASE OF CONFLICT WITH
FIBERGLASS GRATING INCLUDING CLIPS AND ANCHORAGE SHALL
TO ASTM A-276
UNLESS NOTED OTHERWISE ALL STAINLESS STEEL SHALL CONFORM
STAINLESS STEEL CONFORMING TO ASTM A-316.
WEIR VALVE AND ITS COMPONENTS SHALL BE MANUFACTURED OF
ALL STAINLESS STEEL BOLTS SHALL CONFORM TO ASTM A-3041.
2.
3.
ALL ANCHOR BOLTS SHALL BE GALVINIZED.
ALL ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36. 5.
DAMAGE SHALL BE PAINTED IN ACCORDANCE WITH SPECIFICATIONS.
ANY UNCOATED STEEL AREAS OR AREAS OF STEEL WITH COATING
ALL NEW STRUCTURAL STEEL MUST BE G90 HOT-DIPPED GALVANIZED. 4.
3.
WELDS.
NOTED OTHERWISE. E70xx ELECTRODES SHALL BE USED FOR ALL
MINIMUM WELD SIZE FOR STRUCTURAL STEEL IS 3/16" FILLET, UNLESS
CIVIL DRAWINGS SHALL TAKE PRECEDENCE.
STRUCTURAL DRAWINGS AND THE CIVIL DRAWINGS, THE
IF CONFLICTS EXIST BETWEEN DIKE ELEVATIONS PROVIDED IN THE
A.
B.
1. SCOPE OF WORK:
CONFORM TO THE REQUIREMENTS OF ACI 318.
OTHERWISE NOTED. STIRRUPS, TIES, AND 180 DEGREE HOOKS SHALL
90 DEGREE HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS
CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A
DURING CONCRETE PLACEMENT.
POSITIONED, AND MAINTAINED SECURELY IN PLACE PRIOR TO AND
ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY
EMBEDDED ITEMS, UNLESS INDICATED.
REINFORCEMENT SHALL NOT BE CUT TO FACILITATE PLACEMENT OF
RECESSES AND OTHER EMBEDDED ITEMS UNLESS NOTED OTHERWISE.
REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS,
INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
NO CONCRETE SHALL BE PLACED UNTIL THE GOVERNMENT HAS
INDICATED.
ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS
7.
8.
9.
10.
13.
INDEX OF STRUCTURAL SHEETS
GENERAL NOTES
S-201
S-102
S-101
S-001
GENERAL NOTES
LOADING CRITERIA
STAINLESS STEEL
MISCELLANEOUS MATERIALS
CONCRETE CONSTRUCTION NOTES
1N-1 AND 1N-2 PLAN VIEW
1N-3 AND 1N-4 PLAN VIEW
WEIR ELEVATIONS
THE FOLLOWING WORK SHALL BE PERFORMED ON WEIR 1N-2 (STA.46+27):
THE FOLLOWING WORK SHALL BE PERFORMED ON WEIR 1N-1 (STA.48+22)
TIMBER
GALVANIZED.
4. ALL FASTENERS, STAPLES, HARDWARE, AND WIRE ROPE SHALL BE HOT DIP
3. MINIMUM PILE DIAMETER SHALL BE MINIMUM 12".
CONICAL CAPS PERMANENTLY ATTACHED TO THE PILE.
2. MARINE PILE CAPS MUST CONSIST OF FIBERGLASS OR POLYETHYLENE
RETENTION VALUE FOR CCA SHOULD NOT BE LESS THAN 2.5 lb/ft°3
(CCA) CATEGORY UC5C AS OUTLINED BY THE AWPA. MINIMUM
PRESERVATIVE TREATMENT MUST BE COPPER CHROMATED ARSENATE
PRODUCE IN ACCORDANCE WITH WWPI MGT PRACTICES. PILES
RETENTION AND PENETRATION FOR MARINE PILING AND
IN ACCORDANCE WITH AWPA U1 AND AWPA T1 TO THE
1. TREAT WOOD PILING BASED ON USE CATEGORY AND SPECIES
LOADING CRITERIA
4.
3.
2.
1.
EXPOSURE CATEGORY = D
RISK CATEGORY = I
WIND SPEED (ULTIMATE) = 120 MPH (PER ASCE 7-16)
WIND LOADS:
AND OTHER STRUCTURES)
ASCE 7-16 (MINIMUM DESIGN LOADS FOR BUILDING-
UFC 3-301-01, DATED 1 OCT. 2019
DESIGN LOADS ESTABLISHED USING:
WEIRS, AND WEIR FOUNDATIONS.
TO EVALUATE THE CONDITION OF THE EXISTING CATWALKS
IT IS REQUIRED THAT THE CONTRACTOR MAKE A SITE VISIT
CORROSION THAT IS ADVANCED BEYOND SURFACE RUST.
SHOW SIGNS OF CORROSION. SPECIFICALLY, ANY
I. CONTRACTOR SHALL REPLACE ANY MEMBERS THAT
FRAMING AS DETAILED ON SHEET S-102.
H. CONTRACTOR SHALL PROVIDE NEW SAFETY CLIMB ATTACHMENT
CONSTRUCTION.
FOR EXISTING AND NEW CONSTRUCTION PRIOR TO
RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND ELEVATIONS
EXTENSION FOR BIDING PURPOSES. THE CONTRACTOR IS
ELEVATION. THE CONTRACTOR SHALL ASSUME A 4FT WEIR
MATERIALS FOR EXTENDING WEIR 1N-3 AND 1N-4 TO ITS PROPOSED
E. CONTRACTOR SHALL PROVIDE ALL NECESSARY DESIGN AND
ABUTMENT.
UNSUITABLE FOR REUSE THEN CONTRACTOR SHALL PROVIDE NEW
ABUTMENT. IF ABUTMENT IS DAMAGED OR DETERMINED TO BE
D. CONTRACTOR TO REUSE EXISTING CONCRETE CATWALK
CATWALK BENTS.
SEE SHEETS S-102 AND S-201 FOR LOCATION OF
BEAMS, WOOD BRACING AND WOOD CONNECTIONS.
CONSTRUCTION FOR ALL TIMBER PILES, WOOD
CONTRACTOR SHALL PROVIDE DESIGN AND
BENT TO SUPPORT NEW CATWALK SECTION.
C. CONTRACTOR TO PROVIDE (1) NEW TIMBER PILE
1N-2 WEIR WORK CONTINUED (STA.46+27):
GENERAL WEIR RECOMMENDATIONS
4.
3.
2.
1.
4.
5.
6.
WALKWAYS = 40 PSF + POINT LOAD OF 0.3 KIP
LIVE LOADS:
RUST.
CORROSION THAT IS ADVANCED BEYOND SURFACE
SHOW SIGNS OF CORROSION. SPECIFICALLY, ANY
I. CONTRACTOR SHALL REPLACE ANY MEMBERS THAT
ATTACHMENT AS DETAILED ON SHEET S-102.
H. CONTRACTOR SHALL PROVIDE NEW SAFETY CLIMB
WEIR.
ALL TIMBER PILES REQUIRED TO SUPPORT THE 1N-2
CONTRACTOR SHALL DESIGN, SUPPLY, AND INSTALL
SLAB TO ACCOMMODATE RELOCATION OF 1N-2.
G. CONTRACTOR SHALL PROVIDE NEW CONCRETE WEIR
ACCORDANCE WITH ACI 318-14.
CONCRETE DESIGN PERFORMED BY THE CONTRACTOR SHALL BE IN
SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301-05). ALL
PROVISIONS OF THE AMERICAN CONCRETE INSTITUTE (ACI)
ALL CONCRETE CONSTRUCT ON SHALL BE IN ACCORDANCE WITH THE
12.
11.
AND STEEL.
CONCRETE REACTION AND ELECTROLYTIC ACTION BETWEEN ALUMINUM
UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-
ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE
THE FOLLOWING WORK SHALL BE PERFORMED ON WEIR 1N-3/1N-4 (STA.100+83):
DEAD LOADS: ACTUAL WEIGHT OF MATERIALS.
S-001
C.
VERIFIED BY THE CONTRACTORS DESIGN ANALYSIS.
EMBEDMENTS LISTED ON SHEET S-201 ARE MINIMUMS AND SHALL BE
ON CONTRACTORS GEOTECHNICAL INVESTIGATION. THE PILE
DESIGN OF FOUNDATIONS, ABUTMENTS, AND PILING SHALL BE BASED
ASTM A36, Fy = 36 ksiALL OTHER SHAPES:
ASTM A325, FY = 85 ksiBOLTS:
ASTM A500 Gr. B, Fy = 46 ksiHSS:
ASTM A992, Fy = 50 ksiWIDE FLANGE:
MATERIAL STRENGTH:1.
2.
OTHER-WISE.
GALVANIZED, 3/4" DIAMETER TYPE A325N UNLESS NOTED
BOLTS SHALL CONFORM TO ASTM A325. BOLTS SHALL BE
LESS THAN 19 PERCENT.
ALL LUMBER SHALL BE KILN DRIED WITH A MOISTURE CONTENT
THE CONTRACTOR.
COMPLETION OF THIS PROJECT IS THE RESPONSIBILITY OF
OUTLINED IN THE DRAWINGS WHICH ARE NECESSARY FOR THE
CONTRACTOR. COMPONENTS NOT DETAILED OR OTHERWISE
THEIR CONNECTIONS IS THE RESPONSIBILITY OF THE
THE FINAL DESIGN OF ALL MEMBERS AND 5.
6.
STRUCTURAL STEEL NOTES
CONSTRUCTION PRIOR TO CONSTRUCTION.
DIMENSIONS AND ELEVATIONS FOR EXISTING AND NEW
HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
IT IS NOT ANTICIPATED THAT 1N-2 WILL NEED TO BE EXTENDED,
MATERIALS FOR SETTING WEIR 1N-1 TO ITS PROPOSED ELEVATION.
F. CONTRACTOR SHALL PROVIDE ALL NECESSARY DESIGN AND
LOADING CRITERIA
Sdc = C
Sd1 = 0.274
Sds = 0.477
SITE CLASS = E
S1 = 0.120
Ss = 0.310
IMPORTANCE FACTOR = 1.0
RISK CATEGORY = I
SEISMIC LOADS:5.
LOADING CRITERIA CONTINUED
R
E V
IS
E D I
N A
C C
O R
D A
N C
E W
IT
H A
M E
N D
M E
N T
OR DAMAGE.
SHOW SIGNS OF SECTION LOSS DUE TO CORROSION
I. CONTRACTOR SHALL REPLACE ANY MEMBERS THAT
FRAMING AS DETAILED ON SHEET S-102.
H. CONTRACTOR SHALL PROVIDE NEW SAFETY CLIMB ATTACHMENT
SUPPORT THE 1N-1 WEIR.
DESIGN, SUPPLY, AND INSTALL ALL TIMBER PILES REQUIRED TO
ACCOMMODATE RELOCATION OF 1N-1. CONTRACTOR SHALL
G. CONTRACTOR SHALL PROVIDE NEW CONCRETE WEIR SLAB TO
CONSTRUCTION PRIOR TO CONSTRUCTION.
DIMENSIONS AND ELEVATIONS FOR EXISTING AND NEW
HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
IT IS NOT ANTICIPATED THAT 1N-1 WILL NEED TO BE EXTENDED,
MATERIALS FOR SETTING WEIR 1N-1 TO ITS PROPOSED ELEVATION.
F. CONTRACTOR SHALL PROVIDE ALL NECESSARY DESIGN AND
ABUTMENT.
UNSUITABLE FOR REUSE THEN CONTRACTOR SHALL PROVIDE NEW
ABUTMENT. IF ABUTMENT IS DAMAGED OR DETERMINED TO BE
E. CONTRACTOR TO REUSE EXISTING CONCRETE CATWALK
CATWALK BENTS.
SEE SHEETS S-101 AND S-201 FOR LOCATION OF
BEAMS, WOOD BRACING AND WOOD CONNECTIONS.
CONSTRUCTION FOR ALL TIMBER PILES, WOOD
CONTRACTOR SHALL PROVIDE DESIGN AND
BENTS TO SUPPORT NEW CATWALK SECTIONS.
D. CONTRACTOR TO PROVIDE (2) NEW TIMBER PILE
SHOP AND THEN BOLTED IN THE FIELD.
FIELD. PIPE LENGTHS SHORTER THAN 12FT SHALL BE FLANGED IN
EXCEED 12FT IN LENGTH MAY BE BUTT FUSION WELDED IN THE
EXCEPTION: ANY STRAIGHT 48 INCH HDPE PIPE SECTIONS THAT
THEY BE ACCEPTED IF PERFORMED IN THE FIELD.
THE EXCEPTION NOTED BELOW, WILL BE PERMITTED NOR WILL
ENVIRONMENT. NO FUSION OR EXTRUSION WELDS, OTHER THAN
FUSION WELDS AND WEIR WORK IN A CLIMATE CONTROLLED SHOP
COMPONENTS. CONTRACTOR SHALL PERFORM ALL PLASTIC
SPLICING HDPE PIPE, HDPE WEIR AND HDPE WEIR PIPE
CONTRACTOR SHALL SUPPLY ALL PLASTIC WELDS REQUIRED FOR
CONNECTIONS REQUIRED FOR COMPLETE HDPE INSTALLATION.
DESIGN AND PROVIDE ALL NECESSARY ELBOWS, FLANGES, AND
ACCOMMODATE THE 1N-1 WEIR RELOCATION. CONTRACTOR SHALL
C. CONTRACTOR SHALL PROVIDE 90FT OF NEW 48" HDPE PIPE TO
REUSE EXISTING WEIR PLATFORMS.
EXISTING CATWALK FRAMING. CONTRACTOR TO
RELOCATION OF WEIR 1N-1. CONTRACTOR TO MATCH
CATWALK SECTIONS TO ACCOMMODATE THE
B. CONTRACTOR SHALL PROVIDE (2) NEW 30FT
SHEET S-101 AND S-201.
EXISTING LOCATION AND RELOCATE AS SHOWN ON
A. CONTRACTOR SHALL REMOVE WEIR 1N-1 FROM ITS
ABUTMENT.
UNSUITABLE FOR REUSE THEN CONTRACTOR SHALL PROVIDE NEW
ABUTMENT. IF ABUTMENT IS DAMAGED OR DETERMINED TO BE
E. CONTRACTOR TO REUSE EXISTING CONCRETE CATWALK
CATWALK BENTS.
SEE SHEETS S-101 AND S-201 FOR LOCATION OF
BEAMS, WOOD BRACING AND WOOD CONNECTIONS.
CONSTRUCTION FOR ALL TIMBER PILES, WOOD
CONTRACTOR SHALL PROVIDE DESIGN AND
BENTS TO SUPPORT NEW CATWALK SECTIONS.
D. CONTRACTOR TO PROVIDE (2) NEW TIMBER PILE
SHOP AND THEN BOLTED IN THE FIELD.
FIELD. PIPE LENGTHS SHORTER THAN 12FT SHALL BE FLANGED IN
EXCEED 12FT IN LENGTH MAY BE BUTT FUSION WELDED IN THE
EXCEPTION: ANY STRAIGHT 48 INCH HDPE PIPE SECTIONS THAT
THEY BE ACCEPTED IF PERFORMED IN THE FIELD.
THE EXCEPTION NOTED BELOW, WILL BE PERMITTED NOR WILL
ENVIRONMENT. NO FUSION OR EXTRUSION WELDS, OTHER THAN
FUSION WELDS AND WEIR WORK IN A CLIMATE CONTROLLED SHOP
COMPONENTS. CONTRACTOR SHALL PERFORM ALL PLASTIC
SPLICING HDPE PIPE, HDPE WEIR AND HDPE WEIR PIPE
CONTRACTOR SHALL SUPPLY ALL PLASTIC WELDS REQUIRED FOR
CONNECTIONS REQUIRED FOR COMPLETE HDPE INSTALLATION.
DESIGN AND PROVIDE ALL NECESSARY ELBOWS, FLANGES, AND
ACCOMMODATE THE 1N-2 WEIR RELOCATION. CONTRACTOR SHALL
C. CONTRACTOR SHALL PROVIDE 90FT OF NEW 48" HDPE PIPE TO
REUSE EXISTING WEIR PLATFORMS.
EXISTING CATWALK FRAMING. CONTRACTOR TO
RELOCATION OF WEIR 1N-2. CONTRACTOR TO MATCH
CATWALK SECTIONS TO ACCOMMODATE THE
B. CONTRACTOR SHALL PROVIDE (2) NEW 30FT
SHEET S-101 AND S-201.
EXISTING LOCATION AND RELOCATE AS SHOWN ON
A. CONTRACTOR SHALL REMOVE WEIR 1N-2 FROM ITS
THEN BOLTED IN THE FIELD.
SHORTER THAN 12FT SHALL BE FLANGED IN SHOP AND
BUTT FUSION WELDED IN THE FIELD. PIPE LENGTHS
SECTIONS THAT EXCEED 12FT IN LENGTH MAY BE
EXCEPTION: ANY STRAIGHT 48 INCH HDPE PIPE
THEY BE ACCEPTED IF PERFORMED IN THE FIELD.
THE EXCEPTION NOTED BELOW, WILL BE PERMITTED NOR WILL
ENVIRONMENT. NO FUSION OR EXTRUSION WELDS, OTHER THAN
FUSION WELDS AND WEIR WORK IN A CLIMATE CONTROLLED SHOP
COMPONENTS. CONTRACTOR SHALL PERFORM ALL PLASTIC
SPLICING HDPE PIPE, HDPE WEIR AND HDPE WEIR PIPE
B. CONTRACTOR SHALL SUPPLY ALL PLASTIC WELDS REQUIRED FOR
NEW RAISED DIKE ELEVATION.
CATWALK SECTION TO ACCOMMODATE THE
A. CONTRACTOR SHALL PROVIDE (1) NEW 20'-3"
M
A Y
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
L
W
IL
L
IA
M S
SHEET ID
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps
C A
T E
G O
R Y C
O D
E
F
IL
E N
A M
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D E
S C
R
IP
T
IO
N
S A
V A
N N
A H D
IS
T R
IC
T
W
O G
L E
T H
O R
P E A
V E
S A
V A
N N
A H
G A
P
H A
G E
R
P
H A
G E
R
J
W H
IT
T A
K E
R
C w k
S A
V A
N N
A H H
A R
B O
R
G E
O R
G
IA
S A
V A
N N
A H H
A R
B O
R D
M C
A
N D
IK
E R
A
IS
IN
G
F Y
READY TO ADVERTISE (RTA)
W
H N -2
-B -5
M A
R C
H
$$USERNAME$$
$$SYSTIME$$
$$DGNSPEC$$
File details come from the government source that posted it. Updated .