20B3004vol2.PDF

PDF 3 MB Posted

Attached to
Construct Army Family Housing at Fort Gordon, GA - PN87205
Solicitation number
W912HN20B3004
Issued by

About this file

This document provides specifications for the construction of Army Family Housing at Fort Gordon, Georgia under solicitation number W912HN-20-B-3004. The specifications include two volumes of specifications and two volumes of plans for the construction of new housing units to replace existing family housing. The specifications cover requirements for site work, concrete, masonry, wood and plastics, doors and windows, insulation, roofing, siding, flashing, sealants, sprinklers, plumbing, HVAC, electrical systems, equipment, furnishings, finishes, and other construction elements. The solicitation was posted on February 25, 2020 by the Department of the Army Corps of Engineers Savannah District.

View the file

Other files

File Type Posted
C.04 -Abstract W912HN20B3004 Family Housing Ft Gordon.pdf PDF
C.04 - Virtual bid opening attendance roster-W912HN20B3002.pdf PDF
Amd2.pdf PDF
B.08- W912HN20B3004 Conformed.pdf PDF
20B3004vol1.PDF PDF
amd1.pdf PDF
20B3004vol1.PDF PDF
W912HN-20-B-3004_VOL1_AMD1.pdf PDF
W912HN-20-B-3004_VOL1.pdf PDF
20B3004vol2.PDF PDF
W912HN-20-B-3004_VOL1.pdf PDF
W912HN-20-B-3004_VOL2.pdf PDF
20B3004vol1.PDF PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fort Gordon, Georgia

Solicitation Number

W912HN-20-B-3004

Family Housing Replacement Volume 2 of 2: Specification Divisions 08 - 33 and Appendices

PN 87205

February 2020

U.S. ARMY ENGINEER DISTRICT, SAVANNAH

CORPS OF ENGINEERS

100 WEST OGLETHORPE AVENUE

SAVANNAH, GEORGIA 31401-3640

US Army Corps of Engineers Savannah District

Family Housing Replacement 20B3004

PROJECT TABLE OF CONTENTS

DIVISION 01 - GENERAL REQUIREMENTS

01 11 00 SUMMARY OF WORK

01 30 00 ADMINISTRATIVE REQUIREMENTS

01 32 01 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 33 29 SUSTAINABILITY REPORTING

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 42 00 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00 QUALITY CONTROL

01 45 00.15 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)

01 45 35 SPECIAL INSPECTIONS

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS

01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

01 91 00.15 TOTAL BUILDING COMMISSIONING

DIVISION 03 - CONCRETE

03 11 13 STRUCTURAL CAST-IN-PLACE CONCRETE FORMING

03 15 00 CONCRETE ACCESSORIES

03 20 00 CONCRETE REINFORCING

03 30 00 CAST-IN-PLACE CONCRETE

03 35 00 CONCRETE FINISHING

03 39 00 CONCRETE CURING

DIVISION 04 - MASONRY

04 20 00 UNIT MASONRY

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 ROUGH CARPENTRY

06 20 00 FINISH CARPENTRY

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS

07 21 13 BOARD AND BLOCK INSULATION

07 21 16 MINERAL FIBER BLANKET INSULATION

07 21 23 LOOSE FILL THERMAL INSULATION

07 27 10 BUILDING WEATHER (AIR AND WATER) BARRIER SYSTEM

07 31 13 ASPHALT SHINGLE ROOFING

07 46 20 FIBER CEMENT LAP SIDING AND TRIM

07 60 00 FLASHING AND SHEET METAL

07 84 00 FIRESTOPPING

07 92 00 JOINT SEALANTS

DIVISION 08 - OPENINGS

08 11 13 STEEL DOORS AND FRAMES

08 14 00 WOOD DOORS

08 32 13 MULTI-SLIDING GLASS DOORS

08 36 13 SECTIONAL OVERHEAD DOORS

08 53 00 VINYL WINDOWS

PROJECT TABLE OF CONTENTS Page 1

08 71 00 DOOR HARDWARE

DI VI SI ON 09 - FI NI SHES

09 29 00 GYPSUM BOARD

09 30 10 PORCELAIN, STONE, AND GLASS MOSAIC TILING

09 64 29 WOOD STRIP AND PLANK FLOORING

09 68 00 CARPETING

09 72 00 WALLCOVERINGS

09 90 00 PAINTS AND COATINGS

DI VI SI ON 10 - SPECI ALTI ES

10 28 13 TOILET ACCESSORIES

10 82 19 SCREEN WALL PORCH FRAMING AND SCREENING SYSTEM

DI VI SI ON 11 - EQUI PMENT

11 31 13 KITCHEN EQUIPMENT

DI VI SI ON 12 - FURNI SHI NGS

12 21 00 WINDOW SHADES AND BLINDS

12 36 00 COUNTERTOPS

DI VI SI ON 21 - FI RE SUPPRESSI ON

21 21 00 FIRE EXTINGUISHING SPRINKLER SYSTEMS (RESIDENTIAL)

DI VI SI ON 22 - PLUMBI NG

22 00 00 PLUMBING, GENERAL PURPOSE

DI VI SI ON 23 - HEATI NG, VENTI LATI NG, AND AI R CONDI TI ONI NG ( HVAC)

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 11 25 FACILITY GAS PIPING

23 81 00 UNITARY AIR CONDITIONING EQUIPMENT

DI VI SI ON 26 - ELECTRI CAL

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 51 00 INTERIOR LIGHTING

DI VI SI ON 27 - COMMUNI CATI ONS

27 05 14 CABLE TELEVISION PREMISES DISTRIBUTION SYSTEM

27 05 29 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET

COMMUNICATION SYSTEMS

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

DI VI SI ON 31 - EARTHWORK

31 00 00 EARTHWORK

31 11 00 CLEARING AND GRUBBING

31 21 13 RADON MITIGATION

31 31 16.13 CHEMICAL TERMITE CONTROL

PROJECT TABLE OF CONTENTS Page 2

31 31 16.19 TERMITE CONTROL BARRIERS

DI VI SI ON 32 - EXTERI OR I MPROVEMENTS

32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID

PAVEMENTS

32 05 33 LANDSCAPE ESTABLISHMENT

32 11 23 AGGREGATE AND/OR GRADED-CRUSHED AGGREGATE BASE COURSE

32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE

FACILITIES

32 16 13 CONCRETE SIDEWALKS AND CURBS AND GUTTERS

32 17 23 PAVEMENT MARKINGS

32 31 13 CHAIN LINK FENCES AND GATES

32 32 23 *1 DELETED SEGMENTAL CONCRETE BLOCK RETAINING WALL

32 92 19 SEEDING

32 92 23 SODDING

DI VI SI ON 33 - UTI LI TI ES

33 40 00 STORM DRAINAGE UTILITIES

33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION

33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

APPENDICES

Appendix A GEOTECHNICAL REPORT Appendix B FIRE FLOW DATA Appendix C FURNITURE, FIXTURES AND EQUIPMENT Appendix D STRUCTURAL INTERIOR DESIGN

-- End of Project Table of Contents --

PROJECT TABLE OF CONTENTS Page 3

SECTION 08 11 13

STEEL DOORS AND FRAMES

02/10

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A879/A879M (2012) Standard Specification for Steel Sheet, zinc Coated by the Electrolytic Process for Applications Requiring Designation of the Coating Mass on Each Surface

ASTM A924/A924M (2017a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

ASTM C578 (2018) Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation

ASTM C591 (2017) Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation

ASTM C612 (2014) Mineral Fiber Block and Board Thermal Insulation

ASTM D2863 (2017a) Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.115 (2016) Hardware Preparation in Steel Doors and Steel Frames

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 105 (2016; TIA 16-1) Standard for Smoke Door Assemblies and Other Opening Protectives

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

SECTION 08 11 13 Page 1

NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR 113 (2001; R2006) Standard Practice for Determining the Steady State Thermal Transmittance of Steel Door and Frame Assemblies

SDI/DOOR A250.11 (2001) Recommended Erection Instructions for Steel Frames

SDI/DOOR A250.3 (2007; R 2011) Test Procedure and Acceptance Criteria for Factory Applied Finish Painted Steel Surfaces for Steel Doors and Frames

SDI/DOOR A250.4 (2011) Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors and Hardware Reinforcing

SDI/DOOR A250.6 (2003; R2009) Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

UNDERWRITERS LABORATORIES (UL)

UL 10C (2016) UL Standard for Safety Positive Pressure Fire Tests of Door Assemblies

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Doors; G

Frames; G

Accessories

Weatherstripping

Show elevations, construction details, metal gages, hardware provisions, method of glazing, and installation details.

Schedule of Doors; G

SECTION 08 11 13 Page 2

Schedule of Frames; G

Submit door and frame locations.

SD-03 Product Data

Doors; G

Frames; G

Accessories

Submit manufacturer's descriptive literature for doors, frames, and accessories. Include data and details on door construction, panel (internal) reinforcement, insulation, and door edge construction. When "custom hollow metal doors" are provided in lieu of "standard steel doors," provide additional details and data sufficient for comparison to SDI/DOOR A250.8 requirements.

SD-06 Test Reports

Factory-applied enamel finish; G

Door Assembly; G

Submit manufacturer's data that the Storm shelter door assembly has obtained UL classification to ICC 500-2014 and FEMA P-320

1.3 DELIVERY, STORAGE, AND HANDLING

Deliver doors, frames, and accessories undamaged and with protective wrappings or packaging. Strap knock-down frames in bundles. Store doors and frames on platforms under cover in clean, dry, ventilated, and accessible locations, with 1/4 inch airspace between doors. Remove damp or wet packaging immediately and wipe affected surfaces dry. Replace damaged materials with new.

PART 2 PRODUCTS

2.1 INSULATED STEEL DOOR SYSTEMS

Provide paneled insulated steel doors and frames. Provide insulated steel doors in the door size(s), design, and material as specified for standard steel doors. Provide insulated steel doors with a core of polyurethane foam; face sheets, edges, and frames of galvanized steel not lighter than 23 gage, 16 gage, and 16 gage respectively; magnetic weatherstripping;

nonremovable-pin hinges; thermal-break aluminum threshold; and vinyl door bottom. Apply to doors and frames a phosphate treatment, rust-inhibitive primer, and baked acrylic enamel finish. Test doors in accordance with SDI/DOOR A250.4 and meet the requirements for Level C. Prepare doors to receive specified hardware. Provide doors minimum 1-3/4 inch thick.

2.2 SOUND RATED STEEL DOORS

Provide sound rated doors with a Sound Transmission Class (STC) of 45.

SECTION 08 11 13 Page 3

2.3 ACCESSORIES

2.4 INSULATION CORES

Provide insulating cores of the type specified, and provide an apparent U-factor of .48 in accordance with SDI/DOOR 113 and conforming to:

a. Rigid Cellular Polyisocyanurate Foam: ASTM C591, Type I or II, foamed-in-place or in board form, with oxygen index of not less than 22 percent when tested in accordance with ASTM D2863; or

b. Rigid Polystyrene Foam Board: ASTM C578, Type I or II; or

c. Mineral board: ASTM C612, Type I.

2.5 FIRE AND SMOKE DOORS AND FRAMES

NFPA 80 and NFPA 105 and this specification. The requirements of NFPA 80 and NFPA 105 takes precedence over details indicated or specified.

2.5.1 Labels

Provide fire doors and frames bearing the label of Underwriters Laboratories (UL), Factory Mutual Engineering and Research (FM), or Warnock Hersey International (WHI) attesting to the rating required. Testing must be in accordance with NFPA 252 or UL 10C. Provide labels that are metal with raised letters, bearing the name or file number of the door and frame manufacturer. Labels must be permanently affixed at the factory to frames and to the hinge edge of the door. Do not paint door and labels.

2.6 STORM SHELTER DOOR ASSEMBLY

Door, frame, and hardware assembly shall be UL Classified to ICC 50-2014 or FEMA P-320. Frame shall be minimum 16 gauge, with welded corners. Door shall be 14 gauge with steel stiffened polystyrene core.

2.6.1 Hardware

Provide cylindrical locks, dead bolts, strikes, hinges, and all other hardware in accordance with the tested and classified storm shelter door assembly.

2.7 WEATHERSTRIPPING

As specified in Section 08 71 00 DOOR HARDWARE.

2.8 HARDWARE PREPARATION

Provide minimum hardware reinforcing gages as specified in SDI/DOOR A250.6.

Drill and tap doors and frames to receive finish hardware. Prepare doors and frames for hardware in accordance with the applicable requirements of SDI/DOOR A250.8 and SDI/DOOR A250.6. For additional requirements refer to ANSI/BHMA A156.115. Drill and tap for surface-applied hardware at the project site. Build additional reinforcing for surface-applied hardware into the door at the factory. Locate hardware in accordance with the requirements of SDI/DOOR A250.8, as applicable. Punch door frames , with the exception of frames that will have weatherstripping gasketing, to receive a minimum of two rubber or vinyl door silencers on lock side of single doors and one silencer for each leaf at heads of double doors. Set

SECTION 08 11 13 Page 4 lock strikes out to provide clearance for silencers.

2.9 FINISHES

2.9.1 Hot-Dip Zinc-Coated and Factory Primed

Fabricate scheduled doors and frames from hot dipped zinc coated steel, alloyed type, that complies with ASTM A924/A924M and ASTM A653/A653M. The coating weight must meet or exceed the minimum requirements for coatings having 0.4 ounces per square foot, total both sides, i.e., A40. Repair damaged zinc-coated surfaces by the application of zinc dust paint.

Thoroughly clean and chemically treat to insure maximum paint adhesion.

Factory prime as specified in SDI/DOOR A250.8. .

2.9.2 Electrolytic Zinc-Coated Anchors and Accessories

Provide electrolytically deposited zinc-coated steel in accordance with ASTM A879/A879M, Commercial Quality, Coating Class A. Phosphate treat and factory prime zinc-coated surfaces as specified in SDI/DOOR A250.8.

2.9.3 Factory-Applied Enamel Finish

Provide coatings that meet test procedures and acceptance criteria in accordance with SDI/DOOR A250.3. After factory priming, apply two coats of medium-gloss enamel to exposed surfaces. Separately bake or oven dry each coat. Drying time and temperature requirements must be in accordance with the coating manufacturer's recommendations. Provide finish coat color(s) as indicated to match approved color sample(s).

2.10 FABRICATION AND WORKMANSHIP

Provide finished doors and frames that are strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Provide molded members that are clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Dress exposed welded and soldered joints smooth. Design door frame sections for use with the wall construction indicated. Corner joints must be well formed and in true alignment. Conceal fastenings where practicable.

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Frames

Set frames in accordance with SDI/DOOR A250.11. Plumb, align, and brace securely until permanent anchors are set. Anchor bottoms of frames with expansion bolts or powder-actuated fasteners. Build in or secure wall anchors to adjoining construction. Where frames require ceiling struts or overhead bracing, anchor frames to the struts or bracing.

3.1.2 Doors

Hang doors in accordance with clearances specified in SDI/DOOR A250.8.

After erection, clean and adjust hardware.

SECTION 08 11 13 Page 5

3.1.3 Fire and Smoke Doors and Frames

Install fire doors and frames, including hardware, in accordance with NFPA 80. Install fire rated smoke doors and frames in accordance with NFPA 80 and NFPA 105.

3.2 PROTECTION

Protect doors and frames from damage. Repair damaged doors and frames prior to completion and acceptance of the project or replace with new, as directed. Wire brush rusted frames until rust is removed. Clean thoroughly.

3.3 CLEANING

Upon completion, clean exposed surfaces of doors and frames thoroughly.

Remove mastic smears and other unsightly marks.

-- End of Section --

SECTION 08 11 13 Page 6

SECTION 08 14 00

WOOD DOORS

08/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

AMERICAN FOREST FOUNDATION (AFF)

ATFS STANDARDS (2015) American Tree Farm System Standards of Sustainability 2015-2020

ASTM INTERNATIONAL (ASTM)

ASTM E90 (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

CSA GROUP (CSA)

CSA Z809-08 (R2013) Sustainable Forest Management

FOREST STEWARDSHIP COUNCIL (FSC)

FSC STD 01 001 (2015) Principles and Criteria for Forest Stewardship

PROGRAMME FOR ENDORSEMENT OF FOREST CERTIFICATION (PEFC)

PEFC ST 2002:2013 (2015) PEFC International Standard Chain of Custody of Forest Based Products Requirements

SUSTAINABLE FOREST INITIATIVE (SFI)

SFI 2015-2019 (2015) Standards, Rules for Label Use, Procedures and Guidance

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors

ANSI/WDMA I.S.6A (2013) Interior Architectural Stile and Rail Doors

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability

SECTION 08 14 00 Page 1 eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Doors; G

Submit drawings showing each type of door unit . Indicate within drawings and data the door number, types, hardware mounting, and construction, sizes, thickness, vision profile,and finishing and .

SD-03 Product Data

Doors; G

Accessories

Water-resistant Sealer

Sample Warranty

Sound Transmission Class Rating; G

SD-04 Samples

Doors

Prior to the delivery of wood doors, submit a sample section of each type of door which shows the stile, rail, finish, and core construction.

Door Finish Colors; G

Submit a minimum of three color selection samples.

SD-06 Test Reports

Cycle-Slam

Hinge Loading Resistance

Submit cycle-slam test report for doors tested in accordance with ANSI/WDMA I.S.1A, and hinge loading resistance test report for doors tested in accordance with ANSI/WDMA I.S.6A.

SD-07 Certificates

Certificates of Grade

SD-11 Closeout Submittals

Warranty

1.3 CERTIFICATIONS

1.3.1 Certified Wood Grades

Provide certificates of grade from the grading agency on doors.

SECTION 08 14 00 Page 2

1.3.2 Certified Sustainably Harvested Wood

Provide wood certified as sustainably harvested by FSC STD 01 001, ATFS STANDARDS, CSA Z809-08, SFI 2015-2019, or other third party program certified by PEFC ST 2002:2013. Provide a letter of Certification of Sustainably Harvested Wood signed by the wood supplier. Identify certifying organization and their third party program name and indicate compliance with chain-of-custody program requirements. Submit sustainable wood certification data; identify each certified product on a line item basis. Submit copies of invoices bearing certification numbers.

1.3.3 Indoor Air Quality Certification

1.3.3.1 Wood Products

Door construction shall limit use of formaldehyde products during fabrication. Doors shall bear the Four Star rating from the Japanese Ministry of Land, Infrastructure, Transportation and be compliant with California's CARB Phase II program

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver doors to the site in an undamaged condition and protect against damage and dampness. Stack doors flat under cover. Support on blocking, a minimum of 4 inch thick, located at each end and at the midpoint of the door. Store doors in a well-ventilated building so that they will not be exposed to excessive moisture, heat, dryness, direct sunlight, or extreme changes of temperature and humidity. Do not store in a building under construction until concrete, masonry work, and plaster are dry. Replace defective or damaged doors with new ones.

1.5 WARRANTY

Warrant doors free of defects as set forth in the door manufacturer's standard 10 year door warranty.

1.6 QUALITY ASSURANCE

Manufacturer's Qualifications: Company specializing in manufacturing doors with a minimum of five years documented experience

PART 2 PRODUCTS

2.1 DOORS

Provide doors of the types, sizes, and designs indicated specified free of urea-formaldehyde resins.

2.1.1 Interior Stile and Rail Doors (louvered and non-louvered)

Factory prepped and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade. Provide flat panels with a minimum finished panel thickness of 3/8 inch and 3/4 inch thickness for raised panels. Basis of Design is Simpson "Traditional Panel" style or Jeld-Wen "Authentic Wood". Provide wood louvered sections as indicated in drawings.

SECTION 08 14 00 Page 3

2.1.1.1 OFFICE door at GO 1-story unit

As indicated above, except door thickness shall be 2 inch nominal.

2.1.2 Exterior Stile and Rail Entrance.

Water-resistant, factory prepped and primed 1-3/4 inch Paint grade poplar, douglass fir, or suitable hardwood species 2-panelled door with top lite and matching full glass sidelights conforming to ANSI/WDMA I.S.6A premium grade. Provide flat panels with a minimum finished panel thickness of 1/2 inch and 3/4 inch thickness for raised panels. Basis of Design is Simpson "Nantucket" style or Pella "Craftsman" style traditional entry door.

2.1.2.1 Glazing and muttins

Minimum 1/2 inch tempered insulated glazing conforming with ASTM C 1036 with mutton bars as shown in drawings. Glazing shall meet ANSI Z97.1 and U.S.C.P.S.C. STandard 16 CRF 1201.

2.1.3 Pocket Doors (Bathrooms and Pantry)

Top rail mount factory prepped for hardware and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade for high frequency use, and matching the panel design of the other interior wood doors.

2.1.4 Sliding Doors (Between Kitchen and Family Rooms of GO Units)

Top rail mount factory prepped and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade for high frequency use. Provide full divided lites.

2.1.4.1 Glazing and muttins

Minimum 1/4 inch tempered frosted glazing conforming with ASTM C 1036 with mutton bars as shown in drawings, or frosted acrylic. Glazing shall meet ANSI Z97.1 and U.S.C.P.S.C. Standard 16 CRF 1201.

2.1.5 Acoustical OFFICE Door

ANSI/WDMA I.S.1A, solid core, constructed to provide Sound Transmission Class rating of 45 when tested in accordance with ASTM E90.

2.1.6 Prehung Doors

Frames for prehung interior doors to be for painted finish, with 3 piece adjustable jamb units . Provide doors complete with frame, hinges, and prepared to receive finish hardware.

2.2 ACCESSORIES

Refer to Section 08 71 00 DOOR HARDWARE

2.2.1 Door stops

Provide metal door stop with replaceable rubber bumper for swing doors

SECTION 08 14 00 Page 4

2.2.2 Door Louvers

Fabricate from wood and of sizes indicated. Provide louvers with a minimum of 35 percent free air. Equip louvers with sightproof inverted vee slat type. Mount louvers in the door with flush wood moldings.

2.2.3 Additional Hardware Reinforcement

Provide the minimum lock blocks to secure the specified hardware. The measurement of top, bottom, and intermediate rail blocks are a minimum 125 mm 5 inch by full core width. Comply with the manufacturer's labeling requirements for reinforcement blocking.

2.3 FABRICATION

2.3.1 Marking

Stamp each door with a brand, stamp, or other identifying mark indicating quality and construction of the door.

2.3.2 Quality and Construction

Identify the standard on which the construction of the door was based , identify the standard under which preservative treatment was made, and identify doors having a Type I glue bond.

2.3.3 Preservative Treatment

Treat doors scheduled for bathrooms, and exterior doors with a water-repellent preservative treatment and so marketed at the manufacturer's plant.

2.3.4 Adhesives and Bonds

ANSI/WDMA I.S.1A. Use Type I bond for exterior doors and Type II bond for interior doors. Provide a nonstaining adhesive on doors with a natural finish.

2.3.5 Prefitting

Provide factory prefitted doors for the specified hardware, door frame and door-swing indicated. Machine and size doors at the factory by the door manufacturer in accordance with the standards under which the doors are produced and manufactured. The work includes sizing, beveling edges, mortising, and drilling for hardware and providing necessary beaded openings for glass and louvers. Provide the door manufacturer with the necessary hardware samples, and frame and hardware schedules to coordinate the work.

2.3.6 Finishes

2.3.6.1 Field Painting

Factory prime or seal doors, and field paint. Refer to 09 90 00 PAINTS AND

COATINGS.

2.3.6.2 Color

Provide door finish colors as specified.

SECTION 08 14 00 Page 5

2.3.7 Water-Resistant Sealer

For exterior wood doors, provide manufacturer's standard water-resistant sealer compatible with the specified finishes.

2.4 SOURCE QUALITY CONTROL

Meet or exceed the following minimum performance criteria of stiles of "B" and "C" label fire doors utilizing standard mortise leaf hinges:

a. Cycle-slam: Standard Duty Doors: 250,000 cycles with no loose hinge screws or other visible signs of failure when tested in accordance with the requirements of ANSI/WDMA I.S.1A .

b. Hinge loading resistance: Averages of ten test samples not less than Standard Duty doors: 400 pounds force when tested for direct screw withdrawal in accordance with ANSI/WDMA I.S.6A using a No. 12, 1-1/4 inch long, steel, fully threaded wood screw. Drill 5/32 inch pilot hole, use 1-1/2 inch opening around screw for bearing surface, and engage screw full, except for last 1/8 inch. Do not use a steel plate to reinforce screw area.

PART 3 EXECUTION

3.1 INSTALLATION

Do not install building construction materials that show visual evidence of biological growth.

Before installation, seal top and bottom edges of doors with the approved water-resistant sealer. Seal cuts made on the job immediately after cutting using approved water-resistant sealer. Fit, trim, and hang doors with a 1/16 inch minimum, 1/8 inch maximum clearance at sides and top, and a 3/16 inch minimum, 1/4 inch maximum clearance over thresholds. Provide 3/8 inch minimum, 7/16 inch maximum clearance at bottom where no threshold occurs. Bevel edges of doors at the rate of 1/8 inch in 2 inch. Door warp must not exceed 1/4 inch when measured in accordance with ANSI/WDMA I.S.1A.

3.1.1 Prehung Doors

Install doors in accordance with the manufacturer's instructions and details. Provide fasteners for stops and casing trim within 3 inch of each end and spaced 11 inch on center maximum. Provide side and head jambs joined together with a dado or notch of 3/16 inch minimum depth.

SECTION 08 14 00 Page 6

SECTION 08 32 13

MULTI-SLIDING GLASS DOORS

11/08

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 1503 (2009) Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections

AAMA 800 (2016) Voluntary Specifications and Test Methods for Sealants

AAMA/WDMA/CSA 101/I.S.2/A440 (2011; Update 1 2014) North American Fenestration Standard/Specification for Windows, Doors, and Skylights

ASTM INTERNATIONAL (ASTM)

ASTM C1048 (2012; E 2012) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

16 CFR 1201 Safety Standard for Architectural Glazing Materials

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Vinyl sliding glass doors

Submit drawings for sliding glass doors , screens, and accessories that indicate elevations of each door type, full size sections, thickness, nominal gages of metal, fastenings, proposed method of installation and anchoring, the size and spacing and method of glazing, details of operating hardware, method and material for weatherstripping, type of finish, and screen details.

SD-03 Product Data

SECTION 08 32 13 Page 1

Vinyl sliding glass doors

Hardware

Glazing

Weatherstripping

Screens

Finish

Describe each type of sliding glass door, hardware, fastener, accessory, screen, and finish. Include descriptive literature, detailed specifications, and performance test data.

SD-04 Samples

Finish

Submit color chart of factory color coatings when factory-finished color coating is to be provided.

SD-10 Operation and Maintenance Data

Vinyl sliding glass doors, Data Package 1; ; G

Submit in accordance with Section 01 78 23 OPERATION AND

MAINTENANCE DATA.

1.3 TEMPORARY PROTECTIVE COVERING

Prior to shipment from the factory, finished surfaces of vinyl sliding glass doors shall receive a protective covering of waterproof tape, strippable plastic, or cardboard to protect against discoloration and surface damage that may occur during transportation, storage, and construction activities. Also, no coatings or lacquers shall be applied to surfaces to which caulking and glazing compounds must adhere. Covering shall be readily removable after installation.

1.4 DELIVERY AND STORAGE

Inspect sliding glass doors, including screens, hardware and accessories, for damage and unload and store doors upright on platforms in accessible spaces with a minimum of handling. The storage spaces shall be dry, adequately ventilated, free from heavy dust and not subject to combustion products, sources of water or other conditions that could damage the door.

Storage spaces shall have easy access for inspection and handling of doors.

1.5 EXTRA STOCK

Deliver an extra stock of markings for glass panels to the Government for use in future replacement of original markings. The extra stock shall be of the same designs, colors, and materials as the markings installed on this project. Furnish markings in original containers or packages in a quantity not less than 10 percent of the amount of markings to be installed.

SECTION 08 32 13 Page 2

PART 2 PRODUCTS

2.1 VINYL SLIDING GLASS DOORS

Design and construct with sliding panels and fixed panels in the sizes and arrangements indicated and conforming to AAMA/WDMA/CSA 101/I.S.2/A440 for Type SGD-R15, except frame shall be equipped with thermal barrier. Sliding door glazing shall be set in a full-hollow vinyl frames that is reinforced with cold formed steel and stainless steel ball bearing roller assemblies of sufficient strength to withstand lateral live stresses and static load or weight requirements. The Basis of Design: Western Windows System - Series 3600 Vinyl Multi-Slide Stacking Door.

2.1.1 Hardware

Provide all sliding door panel hardware for a complete installation.

Sliding door panels shall have a manually operated adjustable latch on interior and extioer and keyed cylinder lock. Fit sliding screen door panels with a self-latching hook or rotary-type latch operable from both sides. Provide D-style pulls for both inside and outside of sliding panel and the sliding screen panel. Provide auxiliary pin lock top and bottom on inner side of sliding glass door panels opposite manually operated adjustable latch. Exposed hardware to match door color finish.

2.1.2 Glazing

Factory glazed sliding glass doors, including fixed panel, with double-glazed glass conforming to ASTM C1048, Kind FT, Condition A, Type I, Class 1, not less than 1/4 inch thick. Overall nominal thickness shall be 1 inch. Double glazing shall have a low E coating and argon or capillary tube air space. Assembly shall have a minimum condensation resistance factor in accordance with AAMA 1503. Glazing material must be certified as meeting CPSC 16 CFR 1201, Category II. Set glazing unit in polyvinyl-chloride or synthetic rubber glazing channels. Channels shall be reusable when replacing glass and have mitered or continuous corners.

Channels exposed to view shall blend in color with the aluminum frame finish.

2.1.3 Weatherstripping

Provide four sides of each sliding panel and interlocking stiles and jambs with weatherstripping. Weatherstripping shall conform to NFRC and AAMA/WDMA/CSA 101/I.S.2/A440 and shall provide maximum protection against the elements and be designed for ease of replacement. Provide flush sill on Lakeside GO home and Water Barrier Sill on the Streetside GO and CSM homes.

2.1.4 Finish

Vinyl sliding glass doors made from 100% virgin vinyl extrusions. Color shall be Western White.

2.2 CAULKING AND SEALING

As specified under Section 07 92 00 JOINT SEALANTS.

SECTION 08 32 13 Page 3

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Doors, Frames, and Accessories

Install doors, frames, framing members, hardware, and accessories in accordance with approved shop drawings and the requirements specified herein. Set frames securely anchored in place to straight, plumb, square, level condition without distortion and in alignment. Install door panels to retain proper weathering contact with frames. Caulk metal-to-metal joints between frame members and remove excess material. Caulking around perimeter of door frame and wall openings to provide weathertight installation shall be accomplished in accordance with AAMA 800 and manufacturer's recommendations. Finished work shall be rigid, neat in appearance, and free from defects. Upon completion, adjust sliding doors to operate properly. Thoroughly clean aluminum frames and glass in accordance with manufacturer's recommendation. Doors damaged prior to completion and acceptance shall be restored to original manufactured condition or replaced with new doors as directed.

3.1.2 Protection of Aluminum from Dissimilar Materials

3.1.2.1 Aluminum to Dissimilar Metals

Prevent aluminum surfaces from contacting dissimilar metals other than stainless steel, zinc, or white bronze by one or a combination of the following:

a. Paint dissimilar metal with one coat of heavy-bodied bituminous paint.

b. Apply caulking between aluminum and dissimilar metal.

c. Paint dissimilar metal with primer, followed by one coat of aluminum paint or other suitable lead-free coating.

d. Use nonabsorptive tape or gasket in permanently dry locations.

3.1.2.2 Drainage from Dissimilar Metals

Paint dissimilar metals located in areas where their drainage washes over aluminum to prevent the staining of aluminum.

3.1.2.3 Aluminum to Masonry and Concrete

Prevent aluminum surfaces from coming into contact with mortar, concrete, or other masonry materials by applying one coat of heavy-bodied bituminous paint to the aluminum surfaces.

3.1.2.4 Aluminum to Wood

Prevent aluminum surfaces from coming into contact with wood, treated wood, or similarly absorptive materials by one or a combination of the following methods:

a. Paint aluminum surfaces with two coats of aluminum paint or one coat of

SECTION 08 32 13 Page 4 heavy-bodied bituminous paint.

b. Paint the wood, treated wood, or other absorptive surfaces with two coats of aluminum paint and seal contiguous joints with caulking compound.

SECTION 08 32 13 Page 5

SECTION 08 36 13

SECTIONAL OVERHEAD DOORS

08/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products

ASTM A227/A227M (2017) Standard Specification for Steel Wire, Cold-Drawn for Mechanical Springs

ASTM A229/A229M (2017) Standard Specification for Steel Wire, Quenched and Tempered for Mechanical Springs

ASTM A36/A36M (2014) Standard Specification for Carbon Structural Steel

ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM E330/E330M (2014) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

DOOR AND ACCESS SYSTEM MANUFACTURERS ASSOCIATION (DASMA)

ANSI/DASMA 102 (2011) Specifications for Sectional Overhead-Type Doors

ANSI/DASMA 108 (2012) Standard Method for Testing Sectional Garage Doors and Rolling Doors:

Determination of Structural Performance Under Uniform Static Air Pressure Difference

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;

TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;

TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;

TIA 17-11; TIA 17-12; TIA 17-13; TIA

17-14; TIA 17-15; TIA 17-16; TIA 17-17)

SECTION 08 36 13 Page 1

National Electrical Code

UNDERWRITERS LABORATORIES (UL)

UL 325 (2017) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems

1.2 SUBMITTALS

Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES.

SD-02 Shop Drawings

Doors; G

Show types, sizes, locations, metal gages including minimum metal decimal thickness, coating, hardware provisions, installation details, and other details of construction.

SD-03 Product Data

Doors; G Electric operators; G

For electrically motor-operated doors, submit manufacturer's wiring diagrams for motor and controls.

SD-08 Manufacturer's Instructions

Doors

SD-10 Operation and Maintenance Data

Doors; G

Submit Data Package 2 in accordance with Section 01 78 23

OPERATION AND MAINTENANCE DATA.

1.3 DELIVERY, STORAGE, AND HANDLING

Protect doors and accessories from damage during delivery, storage, and handling. Clearly mark manufacturer's brand name. Store doors in dry locations with adequate ventilation, free from dust and water. Remove damaged items and provide new. Provide easy access for inspection and handling of overhead doors prior to installation.

1.4 WARRANTY

Provide limited lifetime warranty on materials and hardware. Provide minimum 5 year warranty against polyurethane delamination from steel face, and minimum 5 year finish warranty.

1.5 QUALITY ASSURANCE

Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum five years documented experience.

SECTION 08 36 13 Page 2

Installer Qualifications: Authorized representative of the manufacturer with minimum five years documented experience

Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. acceptable to authority having jurisdiction as suitable for purpose specified.

PART 2 PRODUCTS

2.1 MATERIALS

2.1.1 Hard-Drawn Springwire

ASTM A227/A227M.

2.1.2 Oil-Tempered Springwire

ASTM A229/A229M.

2.1.3 Steel Sheet

ASTM A653/A653M.

2.1.4 Steel Shapes

ASTM A36/A36M.

2.1.5 Glass

Provide double strength, clear tempered glass 1/4 inch thick.

2.2 DOORS

Metal doors shall comply with ANSI/DASMA 102. Metal doors to have horizontal sections hinged together which operate in a system of tracks to completely close the door opening in the closed position and make the full width and height of the door opening available for use in the open position. Provide a permanent label on the door indicating the name and address of the manufacturer. Doors operate by lifting handles and by electric power. Basis of Design is Wayne-Dalton 9100/9605 series - Ranch style white with Stockbridge IV windows or Overhead Door Company Courtyard Collection for CSM and GO homes. Provide Spear decorative hardwire. Provide lifetime warranty.

2.3 DESIGN REQUIREMENTS

Design wind load shall conform to the design wind load for the building of door area without damage. Doors shall be tested in accordance with either ASTM E330/E330M or ANSI/DASMA 108 and shall meet the acceptance criteria of

ANSI/DASMA 108.

2.4 FABRICATION

2.4.1 Doors

Form 1-1/2" inch nominal thickness door sections of hot-dipped galvanized, powder-coated steel not lighter than 0.012 inches, on each side of longitudinal integral reinforcing ribs. Provide sections of the height and

SECTION 08 36 13 Page 3 width indicated in the drawings. Provide glass panels and install panels using manufacturer's standard rubber gaskets. Door panel sections shall be pinch resistant and have end-cap closures.

2.4.2 Tracks

Provide galvanized steel tracks not lighter than 14 gage thick for 2 inch tracks and not lighter than 12 gage thick for 3 inch tracks. Provide galvanized steel vertical tracks with continuous galvanized steel angle not lighter than 13 gage for installation to walls. Incline vertical track through use of adjustable brackets to obtain a weathertight closure at jambs. Reinforce horizontal track with galvanized steel angle; support from track ceiling construction with galvanized steel angle and cross bracing to provide a rigid installation.

2.4.3 Hardware

Provide hinges, brackets, nylon rollers, locking devices, and other hardware required for complete installation. Install roller brackets and hinges with 14 gage galvanized steel. Provide rollers with ball bearings and case-hardened races. Provide reinforcing on doors where roller hinges are connected. Provide a positive locking device and cylinder lock with two keys on manually operated doors. Provide manual handles and pull string to disengage motor from driver in the event of power failure.

2.4.4 Counterbalancing

Counterbalance doors with an oil-tempered, helical-wound torsional spring mounted on a steel shaft. Provide adjustable spring tension, connect spring to doors with cable through cable drums. Provide cable safety factor of at least 5 to 1.

2.5 ELECTRIC OPERATORS

2.5.1 Operator Features

Operators shall be labeled and listed to the requirements of UL 325 and the Consumer Protection Safety Commission and include safety devices, motion detector lighting, and access security system.

2.5.2 Motors

Provide belt driven motor, not less than 1/2 HP, with opening speed of 10" per second and dual frequency.

2.5.3 Controls

Locate dual frequency 3-button control switch at ADA mounting height at locations within garage next to man door entering into conditioned space, so the operator will have complete visibility of the door at all times.

Provide 2 additional portable battery operated controllers.

2.5.4 Entrapment Protection Devices

Entrapment protection devicesshall be provided for electrically-operated doors in accordance with UL 325. These devices shall immediately stop and reverse the door in its closing travel upon sensing an obstruction in the door opening or upon failure of the device or any component of the control system.

SECTION 08 36 13 Page 4

2.5.5 Electrical Components

NFPA 70. Furnish automatic control and safety devices. Conduit wiring and mounting of controls are specified in the corresponding electrical specification section.

2.6 WEATHER SEALS

Provide exterior doors with weatherproof interlocking joints between sections by means of tongue-and-groove joints, rabbetted joints, shiplap joints, or wool pile, vinyl or rubber weatherstripping; a rubber, or vinyl adjustable weatherstrip at the top and jambs. Provide compressible neoprene or rubber weather seal attached to the bottom of the door.

2.7 FINISHES

2.7.1 Steel

Provide a zinc coating on all steel surfaces, a phosphate treatment, and a shop prime coat of rust-inhibitive paint. Conform to ASTM A653/A653M for galvanized coating, coating designation G60, for steel sheets, and ASTM A123/A123M for assembled steel products. The weight of coatings for assembled products shall be as designated in Table I of ASTM A123/A123M for the class of material to be coated. Provide a prime coat as requried especially developed for materials treated by phosphates and adapted to application by dipping or spraying. Repair damaged zinc-coated surfaces with galvanizing repair paint and spot prime. Prepare all steel in accordance with ASTM D7803 in preparation for 2-coat baked on powder-coated finish.

Provide coating meeting all performance requirements of AAMA 2604.

PART 3 EXECUTION

3.1 EXAMINATION

Do not begin installation until openings and substrates have been properly prepared. Verify wall openings are ready to receive work and opening dimensions and tolerances are within specified limits. Verify electric power is available and of correct characteristics.

3.2 PREPARATION

Clean surfaces thoroughly prior to installation. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

NFPA 70. Install doors in accordance with approved shop drawings and manufacturer's written installation instructions. Securely brace door tracks suspended from structure, securing tracks to structural members only. Lubricate and adjust doors to operate freely. Provide a weathertight installation and free from warp, twist, or distortion. Provide all items and accessories for a complete installation in every respect.

SECTION 08 36 13 Page 5

3.3.1 CLEANING AND ADJUSTING

Adjust door assembly to smooth operation and in full contact with weatherstripping. Clean doors, frames and glass. Remove temporary labels and visible markings. Apply touch up paint as needed.

3.4 ELECTRICAL WORK

NFPA 70. Conduit, wiring, and mounting of controls.

3.5 TESTING

After installation is complete, operate doors to demonstrate installation and function of operators, safety features, and controls. Correct deficiencies.

3.6 PROTECTION

Do not permit construction traffic through overhead door openings after adjustment and cleaning. Protect installed products until completion of project. Touch-up, damaged coatings and finishes and repair minor damage before Substantial Completion.

SECTION 08 36 13 Page 6

SECTION 08 53 00

VINYL WINDOWS

08/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA/WDMA/CSA 101/I.S.2/A440 (2011; Update 1 2014) North American Fenestration Standard/Specification for Windows, Doors, and Skylights

ASTM INTERNATIONAL (ASTM)

ASTM D3656/D3656M (2013) Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass Yarns

ASTM F2090 (2017) Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms

WINDOW COVERING MANUFACTURERS ASSOCIATION (WCMA)

ANSI/WCMA A100.1 (2018) American National Standard for Safety of Window Covering Products

U.S. DEPARTMENT OF ENERGY (DOE)

Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System (FEMP)

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Windows; G

Indicate elevations of windows, full-size sections, thicknesses , reinforcing members, fastenings, proposed method of anchoring, size and spacing of anchors, details of construction, method of glazing, details of operating hardware, mullion details, method and materials for weatherstripping, method of attaching screens, material and method of attaching subframes, fins, stools, casings, sills, trim, window cleaner anchors, accessories, installation details, window flashings and other related items.

SECTION 08 53 00 Page 1

Schedule of Windows; G

Submit with drawings indicating location of each window unit.

SD-03 Product Data

Windows; G

Energy Star Label for All Residential Windows

Fasteners

Hardware

Screens

Weatherstripping

Accessories

Adhesives

SD-04 Samples

Windows; G

Submit one full-size window of each type, complete with certification label indicating conformance to AAMA/WDMA/CSA 101/I.S.2/A440, glazing, hardware, fins, anchors, and other accessories. Where screens or weatherstripping are required, fit sample windows with such items that are to be provided. After approval, install each sample in the work, clearly identified, and record its location.

SD-06 Test Reports

Windows; G

Submit for each window type attesting that identical or larger windows have been tested and meet the requirements specified herein for conformance to AAMA/WDMA/CSA 101/I.S.2/A440 and the specified minimum Condensation Resistance Factor (CRF).

SD-10 Operation and Maintenance Data

Windows, Data Package 1; G

Plastic Identification

When not labeled, identify types in Operation and Maintenance Manual.

1.3 QUALITY ASSURANCE

1.3.1 Labels

Each window unit must bear a certification label from an independent, nationally recognized testing organization validating that the product

SECTION 08 53 00 Page 2 complies with AAMA/WDMA/CSA 101/I.S.2/A440 for the type, grade, and performance class specified.

1.3.2 Certification

Certified test reports attesting that the window units meet the requirements of AAMA/WDMA/CSA 101/I.S.2/A440 as specified will be acceptable in lieu of product labeling or marking.

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver windows to the project site in an undamaged condition. Use care in handling and hoisting windows during transportation and at the job site.

Store windows and components out of contact with the ground, under a weathertight covering, to prevent bending, warping, or otherwise damaging the windows. Store windows and components so they will not have to be handled at minus 20 degrees F or colder. Repair damaged windows to an "as new" condition as approved. Provide new units if windows cannot be repaired.

1.5 PROTECTION

Protect finished surfaces during shipping and handling using the manufacturer's standard method, except do not apply coatings or lacquers on surfaces to receive caulking and glazing compounds.

1.6 MATERIAL IDENTIFICATION

1.6.1 Plastic Identification

Plastic products to be incorporated into the project provide product data indicating polymeric information in Operation and Maintenance Manual.

Type 1: Polyethylene Terephthalate (PET, PETE).

Type 2: High Density Polyethylene (HDPE).

Type 3: Vinyl (Polyvinyl Chloride or PVC).

Type 4: Low Density Polyethylene (LDPE).

Type 5: Polypropylene (PP).

Type 6: Polystyrene (PS).

Type 7: Other. Use of this code indicates that the package in question is made with a resin other than the six listed above, or is made of more than one resin listed above, and used in a multi-layer combination.

PART 2 PRODUCTS

2.1 GENERAL REQUIREMENTS FOR WINDOWS

Provide windows conforming to AAMA/WDMA/CSA 101/I.S.2/A440 and to requirements specified herein. Provide windows of materials, types, grades, performance classes, combinations and sizes indicated or specified.

Provide each window as a unit consisting of subframe, frame, sash, glass, hardware, mullions, fins, trim, casing, screen, weatherstripping, anchors and accessories complete.