20B3004vol2.PDF
PDF 3 MB Posted
- Solicitation number
- W912HN20B3004
About this file
This document provides the specifications for the construction of Army family housing at Fort Gordon, Georgia. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Savannah on February 25, 2020 for the construction of replacement family housing at Fort Gordon. The solicitation includes two volumes of specifications and two volumes of plans. The specifications cover requirements for site work, concrete, masonry, wood and plastics, thermal and moisture protection, openings, finishes, specialties, equipment, furnishings, special construction, conveyance equipment, mechanical, electrical, earthwork, exterior improvements, and utilities. Bids for the work must be submitted in response to the requirements laid out in the specifications and plans.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fort Gordon, Georgia
Solicitation Number
W912HN-20-B-3004
Family Housing Replacement Volume 2 of 2: Specification Divisions 08 - 33 and Appendices
PN 87205
February 2020
U.S. ARMY ENGINEER DISTRICT, SAVANNAH
CORPS OF ENGINEERS
100 WEST OGLETHORPE AVENUE
SAVANNAH, GEORGIA 31401-3640
US Army Corps of Engineers Savannah District
Family Housing Replacement 20B3004 Ft. Gordon,, GA
PROJECT TABLE OF CONTENTS
DIVISION 01 - GENERAL REQUIREMENTS
01 11 00 SUMMARY OF WORK
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 32 01 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 33 29 SUSTAINABILITY REPORTING
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00 QUALITY CONTROL
01 45 00.15 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
01 45 35 SPECIAL INSPECTIONS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 78 00 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
01 91 00.15 TOTAL BUILDING COMMISSIONING
DIVISION 03 - CONCRETE
03 11 13 STRUCTURAL CAST-IN-PLACE CONCRETE FORMING
03 15 00 CONCRETE ACCESSORIES
03 20 00 CONCRETE REINFORCING
03 30 00 CAST-IN-PLACE CONCRETE
03 35 00 CONCRETE FINISHING
03 39 00 CONCRETE CURING
DIVISION 04 - MASONRY
04 20 00 UNIT MASONRY
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 20 00 FINISH CARPENTRY
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 21 23 LOOSE FILL THERMAL INSULATION
07 27 10 BUILDING WEATHER (AIR AND WATER) BARRIER SYSTEM
07 31 13 ASPHALT SHINGLE ROOFING
07 46 20 FIBER CEMENT LAP SIDING AND TRIM
07 60 00 FLASHING AND SHEET METAL
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 32 13 MULTI-SLIDING GLASS DOORS
08 36 13 SECTIONAL OVERHEAD DOORS
08 53 00 VINYL WINDOWS
PROJECT TABLE OF CONTENTS Page 1
08 71 00 DOOR HARDWARE
DIVISION 09 - FINISHES
09 29 00 GYPSUM BOARD
09 30 10 PORCELAIN, STONE, AND GLASS MOSAIC TILING
09 64 29 WOOD STRIP AND PLANK FLOORING
09 68 00 CARPETING
09 72 00 WALLCOVERINGS
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 28 13 TOILET ACCESSORIES
10 82 19 SCREEN WALL PORCH FRAMING AND SCREENING SYSTEM
DIVISION 11 - EQUIPMENT
11 31 13 KITCHEN EQUIPMENT
DIVISION 12 - FURNISHINGS
12 21 00 WINDOW SHADES AND BLINDS
12 36 00 COUNTERTOPS
DIVISION 21 - FIRE SUPPRESSION
21 21 00 FIRE EXTINGUISHING SPRINKLER SYSTEMS (RESIDENTIAL)
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 11 25 FACILITY GAS PIPING
23 81 00 UNITARY AIR CONDITIONING EQUIPMENT
DIVISION 26 - ELECTRICAL
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 51 00 INTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 05 14 CABLE TELEVISION PREMISES DISTRIBUTION SYSTEM
27 05 29 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET
COMMUNICATION SYSTEMS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
DIVISION 31 - EARTHWORK
31 00 00 EARTHWORK
31 11 00 CLEARING AND GRUBBING
31 21 13 RADON MITIGATION
31 31 16.13 CHEMICAL TERMITE CONTROL
PROJECT TABLE OF CONTENTS Page 2
31 31 16.19 TERMITE CONTROL BARRIERS
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID
PAVEMENTS
32 05 33 LANDSCAPE ESTABLISHMENT
32 11 23 AGGREGATE AND/OR GRADED-CRUSHED AGGREGATE BASE COURSE
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
32 16 13 CONCRETE SIDEWALKS AND CURBS AND GUTTERS
32 17 23 PAVEMENT MARKINGS
32 31 13 CHAIN LINK FENCES AND GATES
32 32 23 SEGMENTAL CONCRETE BLOCK RETAINING WALL
32 92 19 SEEDING
32 92 23 SODDING
DIVISION 33 - UTILITIES
33 40 00 STORM DRAINAGE UTILITIES
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
APPENDICES
Appendix A GEOTECHNICAL REPORT Appendix B FIRE FLOW DATA Appendix C FURNITURE, FIXTURES AND EQUIPMENT Appendix D STRUCTURAL INTERIOR DESIGN
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 3
SECTION 08 11 13
STEEL DOORS AND FRAMES
02/10
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A879/A879M (2012) Standard Specification for Steel Sheet, zinc Coated by the Electrolytic Process for Applications Requiring Designation of the Coating Mass on Each Surface
ASTM A924/A924M (2017a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM C578 (2018) Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
ASTM C591 (2017) Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation
ASTM C612 (2014) Mineral Fiber Block and Board Thermal Insulation
ASTM D2863 (2017a) Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.115 (2016) Hardware Preparation in Steel Doors and Steel Frames
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 105 (2016; TIA 16-1) Standard for Smoke Door Assemblies and Other Opening Protectives
NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies
SECTION 08 11 13 Page 1
NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR 113 (2001; R2006) Standard Practice for Determining the Steady State Thermal Transmittance of Steel Door and Frame Assemblies
SDI/DOOR A250.11 (2001) Recommended Erection Instructions for Steel Frames
SDI/DOOR A250.3 (2007; R 2011) Test Procedure and Acceptance Criteria for Factory Applied Finish Painted Steel Surfaces for Steel Doors and Frames
SDI/DOOR A250.4 (2011) Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors and Hardware Reinforcing
SDI/DOOR A250.6 (2003; R2009) Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
UNDERWRITERS LABORATORIES (UL)
UL 10C (2016) UL Standard for Safety Positive Pressure Fire Tests of Door Assemblies
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Doors; G
Frames; G
Accessories
Weatherstripping
Show elevations, construction details, metal gages, hardware provisions, method of glazing, and installation details.
Schedule of Doors; G
SECTION 08 11 13 Page 2
Schedule of Frames; G
Submit door and frame locations.
SD-03 Product Data
Doors; G
Frames; G
Accessories
Submit manufacturer's descriptive literature for doors, frames, and accessories. Include data and details on door construction, panel (internal) reinforcement, insulation, and door edge construction. When "custom hollow metal doors" are provided in lieu of "standard steel doors," provide additional details and data sufficient for comparison to SDI/DOOR A250.8 requirements.
SD-06 Test Reports
Factory-applied enamel finish; G
Door Assembly; G
Submit manufacturer's data that the Storm shelter door assembly has obtained UL classification to ICC 500-2014 and FEMA P-320
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver doors, frames, and accessories undamaged and with protective wrappings or packaging. Strap knock-down frames in bundles. Store doors and frames on platforms under cover in clean, dry, ventilated, and accessible locations, with 1/4 inch airspace between doors. Remove damp or wet packaging immediately and wipe affected surfaces dry. Replace damaged materials with new.
PART 2 PRODUCTS
2.1 INSULATED STEEL DOOR SYSTEMS
Provide paneled insulated steel doors and frames. Provide insulated steel doors in the door size(s), design, and material as specified for standard steel doors. Provide insulated steel doors with a core of polyurethane foam; face sheets, edges, and frames of galvanized steel not lighter than 23 gage, 16 gage, and 16 gage respectively; magnetic weatherstripping;
nonremovable-pin hinges; thermal-break aluminum threshold; and vinyl door bottom. Apply to doors and frames a phosphate treatment, rust-inhibitive primer, and baked acrylic enamel finish. Test doors in accordance with SDI/DOOR A250.4 and meet the requirements for Level C. Prepare doors to receive specified hardware. Provide doors minimum 1-3/4 inch thick.
2.2 SOUND RATED STEEL DOORS
Provide sound rated doors with a Sound Transmission Class (STC) of 45.
SECTION 08 11 13 Page 3
2.3 ACCESSORIES
2.4 INSULATION CORES
Provide insulating cores of the type specified, and provide an apparent U-factor of .48 in accordance with SDI/DOOR 113 and conforming to:
a. Rigid Cellular Polyisocyanurate Foam: ASTM C591, Type I or II, foamed-in-place or in board form, with oxygen index of not less than 22 percent when tested in accordance with ASTM D2863; or
b. Rigid Polystyrene Foam Board: ASTM C578, Type I or II; or
c. Mineral board: ASTM C612, Type I.
2.5 FIRE AND SMOKE DOORS AND FRAMES
NFPA 80 and NFPA 105 and this specification. The requirements of NFPA 80 and NFPA 105 takes precedence over details indicated or specified.
2.5.1 Labels
Provide fire doors and frames bearing the label of Underwriters Laboratories (UL), Factory Mutual Engineering and Research (FM), or Warnock Hersey International (WHI) attesting to the rating required. Testing must be in accordance with NFPA 252 or UL 10C. Provide labels that are metal with raised letters, bearing the name or file number of the door and frame manufacturer. Labels must be permanently affixed at the factory to frames and to the hinge edge of the door. Do not paint door and labels.
2.6 STORM SHELTER DOOR ASSEMBLY
Door, frame, and hardware assembly shall be UL Classified to ICC 50-2014 or FEMA P-320. Frame shall be minimum 16 gauge, with welded corners. Door shall be 14 gauge with steel stiffened polystyrene core.
2.6.1 Hardware
Provide cylindrical locks, dead bolts, strikes, hinges, and all other hardware in accordance with the tested and classified storm shelter door assembly.
2.7 WEATHERSTRIPPING
As specified in Section 08 71 00 DOOR HARDWARE.
2.8 HARDWARE PREPARATION
Provide minimum hardware reinforcing gages as specified in SDI/DOOR A250.6.
Drill and tap doors and frames to receive finish hardware. Prepare doors and frames for hardware in accordance with the applicable requirements of SDI/DOOR A250.8 and SDI/DOOR A250.6. For additional requirements refer to ANSI/BHMA A156.115. Drill and tap for surface-applied hardware at the project site. Build additional reinforcing for surface-applied hardware into the door at the factory. Locate hardware in accordance with the requirements of SDI/DOOR A250.8, as applicable. Punch door frames , with the exception of frames that will have weatherstripping gasketing, to receive a minimum of two rubber or vinyl door silencers on lock side of single doors and one silencer for each leaf at heads of double doors. Set
SECTION 08 11 13 Page 4 lock strikes out to provide clearance for silencers.
2.9 FINISHES
2.9.1 Hot-Dip Zinc-Coated and Factory Primed
Fabricate scheduled doors and frames from hot dipped zinc coated steel, alloyed type, that complies with ASTM A924/A924M and ASTM A653/A653M. The coating weight must meet or exceed the minimum requirements for coatings having 0.4 ounces per square foot, total both sides, i.e., A40. Repair damaged zinc-coated surfaces by the application of zinc dust paint.
Thoroughly clean and chemically treat to insure maximum paint adhesion.
Factory prime as specified in SDI/DOOR A250.8. .
2.9.2 Electrolytic Zinc-Coated Anchors and Accessories
Provide electrolytically deposited zinc-coated steel in accordance with ASTM A879/A879M, Commercial Quality, Coating Class A. Phosphate treat and factory prime zinc-coated surfaces as specified in SDI/DOOR A250.8.
2.9.3 Factory-Applied Enamel Finish
Provide coatings that meet test procedures and acceptance criteria in accordance with SDI/DOOR A250.3. After factory priming, apply two coats of medium-gloss enamel to exposed surfaces. Separately bake or oven dry each coat. Drying time and temperature requirements must be in accordance with the coating manufacturer's recommendations. Provide finish coat color(s) as indicated to match approved color sample(s).
2.10 FABRICATION AND WORKMANSHIP
Provide finished doors and frames that are strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Provide molded members that are clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Dress exposed welded and soldered joints smooth. Design door frame sections for use with the wall construction indicated. Corner joints must be well formed and in true alignment. Conceal fastenings where practicable.
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Frames
Set frames in accordance with SDI/DOOR A250.11. Plumb, align, and brace securely until permanent anchors are set. Anchor bottoms of frames with expansion bolts or powder-actuated fasteners. Build in or secure wall anchors to adjoining construction. Where frames require ceiling struts or overhead bracing, anchor frames to the struts or bracing.
3.1.2 Doors
Hang doors in accordance with clearances specified in SDI/DOOR A250.8.
After erection, clean and adjust hardware.
SECTION 08 11 13 Page 5
3.1.3 Fire and Smoke Doors and Frames
Install fire doors and frames, including hardware, in accordance with NFPA 80. Install fire rated smoke doors and frames in accordance with NFPA 80 and NFPA 105.
3.2 PROTECTION
Protect doors and frames from damage. Repair damaged doors and frames prior to completion and acceptance of the project or replace with new, as directed. Wire brush rusted frames until rust is removed. Clean thoroughly.
3.3 CLEANING
Upon completion, clean exposed surfaces of doors and frames thoroughly.
Remove mastic smears and other unsightly marks.
-- End of Section --
SECTION 08 11 13 Page 6
SECTION 08 14 00
WOOD DOORS
08/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
AMERICAN FOREST FOUNDATION (AFF)
ATFS STANDARDS (2015) American Tree Farm System Standards of Sustainability 2015-2020
ASTM INTERNATIONAL (ASTM)
ASTM E90 (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
CSA GROUP (CSA)
CSA Z809-08 (R2013) Sustainable Forest Management
FOREST STEWARDSHIP COUNCIL (FSC)
FSC STD 01 001 (2015) Principles and Criteria for Forest Stewardship
PROGRAMME FOR ENDORSEMENT OF FOREST CERTIFICATION (PEFC)
PEFC ST 2002:2013 (2015) PEFC International Standard Chain of Custody of Forest Based Products Requirements
SUSTAINABLE FOREST INITIATIVE (SFI)
SFI 2015-2019 (2015) Standards, Rules for Label Use, Procedures and Guidance
WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)
ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors
ANSI/WDMA I.S.6A (2013) Interior Architectural Stile and Rail Doors
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability
SECTION 08 14 00 Page 1 eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Doors; G
Submit drawings showing each type of door unit . Indicate within drawings and data the door number, types, hardware mounting, and construction, sizes, thickness, vision profile,and finishing and .
SD-03 Product Data
Doors; G
Accessories
Water-resistant Sealer
Sample Warranty
Sound Transmission Class Rating; G
SD-04 Samples
Doors
Prior to the delivery of wood doors, submit a sample section of each type of door which shows the stile, rail, finish, and core construction.
Door Finish Colors; G
Submit a minimum of three color selection samples.
SD-06 Test Reports
Cycle-Slam
Hinge Loading Resistance
Submit cycle-slam test report for doors tested in accordance with ANSI/WDMA I.S.1A, and hinge loading resistance test report for doors tested in accordance with ANSI/WDMA I.S.6A.
SD-07 Certificates
Certificates of Grade
SD-11 Closeout Submittals
Warranty
1.3 CERTIFICATIONS
1.3.1 Certified Wood Grades
Provide certificates of grade from the grading agency on doors.
SECTION 08 14 00 Page 2
1.3.2 Certified Sustainably Harvested Wood
Provide wood certified as sustainably harvested by FSC STD 01 001, ATFS STANDARDS, CSA Z809-08, SFI 2015-2019, or other third party program certified by PEFC ST 2002:2013. Provide a letter of Certification of Sustainably Harvested Wood signed by the wood supplier. Identify certifying organization and their third party program name and indicate compliance with chain-of-custody program requirements. Submit sustainable wood certification data; identify each certified product on a line item basis. Submit copies of invoices bearing certification numbers.
1.3.3 Indoor Air Quality Certification
1.3.3.1 Wood Products
Door construction shall limit use of formaldehyde products during fabrication. Doors shall bear the Four Star rating from the Japanese Ministry of Land, Infrastructure, Transportation and be compliant with California's CARB Phase II program
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver doors to the site in an undamaged condition and protect against damage and dampness. Stack doors flat under cover. Support on blocking, a minimum of 4 inch thick, located at each end and at the midpoint of the door. Store doors in a well-ventilated building so that they will not be exposed to excessive moisture, heat, dryness, direct sunlight, or extreme changes of temperature and humidity. Do not store in a building under construction until concrete, masonry work, and plaster are dry. Replace defective or damaged doors with new ones.
1.5 WARRANTY
Warrant doors free of defects as set forth in the door manufacturer's standard 10 year door warranty.
1.6 QUALITY ASSURANCE
Manufacturer's Qualifications: Company specializing in manufacturing doors with a minimum of five years documented experience
PART 2 PRODUCTS
2.1 DOORS
Provide doors of the types, sizes, and designs indicated specified free of urea-formaldehyde resins.
2.1.1 Interior Stile and Rail Doors (louvered and non-louvered)
Factory prepped and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade. Provide flat panels with a minimum finished panel thickness of 3/8 inch and 3/4 inch thickness for raised panels. Basis of Design is Simpson "Traditional Panel" style or Jeld-Wen "Authentic Wood". Provide wood louvered sections as indicated in drawings.
SECTION 08 14 00 Page 3
2.1.1.1 OFFICE door at GO 1-story unit
As indicated above, except door thickness shall be 2 inch nominal.
2.1.2 Exterior Stile and Rail Entrance.
Water-resistant, factory prepped and primed 1-3/4 inch Paint grade poplar, douglass fir, or suitable hardwood species 2-panelled door with top lite and matching full glass sidelights conforming to ANSI/WDMA I.S.6A premium grade. Provide flat panels with a minimum finished panel thickness of 1/2 inch and 3/4 inch thickness for raised panels. Basis of Design is Simpson "Nantucket" style or Pella "Craftsman" style traditional entry door.
2.1.2.1 Glazing and muttins
Minimum 1/2 inch tempered insulated glazing conforming with ASTM C 1036 with mutton bars as shown in drawings. Glazing shall meet ANSI Z97.1 and U.S.C.P.S.C. STandard 16 CRF 1201.
2.1.3 Pocket Doors (Bathrooms and Pantry)
Top rail mount factory prepped for hardware and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade for high frequency use, and matching the panel design of the other interior wood doors.
2.1.4 Sliding Doors (Between Kitchen and Family Rooms of GO Units)
Top rail mount factory prepped and primed 1-3/8 inch Paint grade poplar, douglass fir, or equivalant species panelled doors conforming to ANSI/WDMA I.S.6A premium grade for high frequency use. Provide full divided lites.
2.1.4.1 Glazing and muttins
Minimum 1/4 inch tempered frosted glazing conforming with ASTM C 1036 with mutton bars as shown in drawings, or frosted acrylic. Glazing shall meet ANSI Z97.1 and U.S.C.P.S.C. Standard 16 CRF 1201.
2.1.5 Acoustical OFFICE Door
ANSI/WDMA I.S.1A, solid core, constructed to provide Sound Transmission Class rating of 45 when tested in accordance with ASTM E90.
2.1.6 Prehung Doors
Frames for prehung interior doors to be for painted finish, with 3 piece adjustable jamb units . Provide doors complete with frame, hinges, and prepared to receive finish hardware.
2.2 ACCESSORIES
Refer to Section 08 71 00 DOOR HARDWARE
2.2.1 Door stops
Provide metal door stop with replaceable rubber bumper for swing doors
SECTION 08 14 00 Page 4
2.2.2 Door Louvers
Fabricate from wood and of sizes indicated. Provide louvers with a minimum of 35 percent free air. Equip louvers with sightproof inverted vee slat type. Mount louvers in the door with flush wood moldings.
2.2.3 Additional Hardware Reinforcement
Provide the minimum lock blocks to secure the specified hardware. The measurement of top, bottom, and intermediate rail blocks are a minimum 125 mm 5 inch by full core width. Comply with the manufacturer's labeling requirements for reinforcement blocking.
2.3 FABRICATION
2.3.1 Marking
Stamp each door with a brand, stamp, or other identifying mark indicating quality and construction of the door.
2.3.2 Quality and Construction
Identify the standard on which the construction of the door was based , identify the standard under which preservative treatment was made, and identify doors having a Type I glue bond.
2.3.3 Preservative Treatment
Treat doors scheduled for bathrooms, and exterior doors with a water-repellent preservative treatment and so marketed at the manufacturer's plant.
2.3.4 Adhesives and Bonds
ANSI/WDMA I.S.1A. Use Type I bond for exterior doors and Type II bond for interior doors. Provide a nonstaining adhesive on doors with a natural finish.
2.3.5 Prefitting
Provide factory prefitted doors for the specified hardware, door frame and door-swing indicated. Machine and size doors at the factory by the door manufacturer in accordance with the standards under which the doors are produced and manufactured. The work includes sizing, beveling edges, mortising, and drilling for hardware and providing necessary beaded openings for glass and louvers. Provide the door manufacturer with the necessary hardware samples, and frame and hardware schedules to coordinate the work.
2.3.6 Finishes
2.3.6.1 Field Painting
Factory prime or seal doors, and field paint. Refer to 09 90 00 PAINTS AND
COATINGS.
2.3.6.2 Color
Provide door finish colors as specified.
SECTION 08 14 00 Page 5
2.3.7 Water-Resistant Sealer
For exterior wood doors, provide manufacturer's standard water-resistant sealer compatible with the specified finishes.
2.4 SOURCE QUALITY CONTROL
Meet or exceed the following minimum performance criteria of stiles of "B" and "C" label fire doors utilizing standard mortise leaf hinges:
a. Cycle-slam: Standard Duty Doors: 250,000 cycles with no loose hinge screws or other visible signs of failure when tested in accordance with the requirements of ANSI/WDMA I.S.1A .
b. Hinge loading resistance: Averages of ten test samples not less than Standard Duty doors: 400 pounds force when tested for direct screw withdrawal in accordance with ANSI/WDMA I.S.6A using a No. 12, 1-1/4 inch long, steel, fully threaded wood screw. Drill 5/32 inch pilot hole, use 1-1/2 inch opening around screw for bearing surface, and engage screw full, except for last 1/8 inch. Do not use a steel plate to reinforce screw area.
PART 3 EXECUTION
3.1 INSTALLATION
Do not install building construction materials that show visual evidence of biological growth.
Before installation, seal top and bottom edges of doors with the approved water-resistant sealer. Seal cuts made on the job immediately after cutting using approved water-resistant sealer. Fit, trim, and hang doors with a 1/16 inch minimum, 1/8 inch maximum clearance at sides and top, and a 3/16 inch minimum, 1/4 inch maximum clearance over thresholds. Provide 3/8 inch minimum, 7/16 inch maximum clearance at bottom where no threshold occurs. Bevel edges of doors at the rate of 1/8 inch in 2 inch. Door warp must not exceed 1/4 inch when measured in accordance with ANSI/WDMA I.S.1A.
3.1.1 Prehung Doors
Install doors in accordance with the manufacturer's instructions and details. Provide fasteners for stops and casing trim within 3 inch of each end and spaced 11 inch on center maximum. Provide side and head jambs joined together with a dado or notch of 3/16 inch minimum depth.
SECTION 08 14 00 Page 6
SECTION 08 32 13
MULTI-SLIDING GLASS DOORS
11/08
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 1503 (2009) Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections
AAMA 800 (2016) Voluntary Specifications and Test Methods for Sealants
AAMA/WDMA/CSA 101/I.S.2/A440 (2011; Update 1 2014) North American Fenestration Standard/Specification for Windows, Doors, and Skylights
ASTM INTERNATIONAL (ASTM)
ASTM C1048 (2012; E 2012) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
16 CFR 1201 Safety Standard for Architectural Glazing Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Vinyl sliding glass doors
Submit drawings for sliding glass doors , screens, and accessories that indicate elevations of each door type, full size sections, thickness, nominal gages of metal, fastenings, proposed method of installation and anchoring, the size and spacing and method of glazing, details of operating hardware, method and material for weatherstripping, type of finish, and screen details.
SD-03 Product Data
SECTION 08 32 13 Page 1
Vinyl sliding glass doors
Hardware
Glazing
Weatherstripping
Screens
Finish
Describe each type of sliding glass door, hardware, fastener, accessory, screen, and finish. Include descriptive literature, detailed specifications, and performance test data.
SD-04 Samples
Finish
Submit color chart of factory color coatings when factory-finished color coating is to be provided.
SD-10 Operation and Maintenance Data
Vinyl sliding glass doors, Data Package 1; ; G
Submit in accordance with Section 01 78 23 OPERATION AND
MAINTENANCE DATA.
1.3 TEMPORARY PROTECTIVE COVERING
Prior to shipment from the factory, finished surfaces of vinyl sliding glass doors shall receive a protective covering of waterproof tape, strippable plastic, or cardboard to protect against discoloration and surface damage that may occur during transportation, storage, and construction activities. Also, no coatings or lacquers shall be applied to surfaces to which caulking and glazing compounds must adhere. Covering shall be readily removable after installation.
1.4 DELIVERY AND STORAGE
Inspect sliding glass doors, including screens, hardware and accessories, for damage and unload and store doors upright on platforms in accessible spaces with a minimum of handling. The storage spaces shall be dry, adequately ventilated, free from heavy dust and not subject to combustion products, sources of water or other conditions that could damage the door.
Storage spaces shall have easy access for inspection and handling of doors.
1.5 EXTRA STOCK
Deliver an extra stock of markings for glass panels to the Government for use in future replacement of original markings. The extra stock shall be of the same designs, colors, and materials as the markings installed on this project. Furnish markings in original containers or packages in a quantity not less than 10 percent of the amount of markings to be installed.
SECTION 08 32 13 Page 2
PART 2 PRODUCTS
2.1 VINYL SLIDING GLASS DOORS
Design and construct with sliding panels and fixed panels in the sizes and arrangements indicated and conforming to AAMA/WDMA/CSA 101/I.S.2/A440 for Type SGD-R15, except frame shall be equipped with thermal barrier. Sliding door glazing shall be set in a full-hollow vinyl frames that is reinforced with cold formed steel and stainless steel ball bearing roller assemblies of sufficient strength to withstand lateral live stresses and static load or weight requirements. The Basis of Design: Western Windows System - Series 3600 Vinyl Multi-Slide Stacking Door.
2.1.1 Hardware
Provide all sliding door panel hardware for a complete installation.
Sliding door panels shall have a manually operated adjustable latch on interior and extioer and keyed cylinder lock. Fit sliding screen door panels with a self-latching hook or rotary-type latch operable from both sides. Provide D-style pulls for both inside and outside of sliding panel and the sliding screen panel. Provide auxiliary pin lock top and bottom on inner side of sliding glass door panels opposite manually operated adjustable latch. Exposed hardware to match door color finish.
2.1.2 Glazing
Factory glazed sliding glass doors, including fixed panel, with double-glazed glass conforming to ASTM C1048, Kind FT, Condition A, Type I, Class 1, not less than 1/4 inch thick. Overall nominal thickness shall be 1 inch. Double glazing shall have a low E coating and argon or capillary tube air space. Assembly shall have a minimum condensation resistance factor in accordance with AAMA 1503. Glazing material must be certified as meeting CPSC 16 CFR 1201, Category II. Set glazing unit in polyvinyl-chloride or synthetic rubber glazing channels. Channels shall be reusable when replacing glass and have mitered or continuous corners.
Channels exposed to view shall blend in color with the aluminum frame finish.
2.1.3 Weatherstripping
Provide four sides of each sliding panel and interlocking stiles and jambs with weatherstripping. Weatherstripping shall conform to NFRC and AAMA/WDMA/CSA 101/I.S.2/A440 and shall provide maximum protection against the elements and be designed for ease of replacement. Provide flush sill on Lakeside GO home and Water Barrier Sill on the Streetside GO and CSM homes.
2.1.4 Finish
Vinyl sliding glass doors made from 100% virgin vinyl extrusions. Color shall be Western White.
2.2 CAULKING AND SEALING
As specified under Section 07 92 00 JOINT SEALANTS.
SECTION 08 32 13 Page 3
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Doors, Frames, and Accessories
Install doors, frames, framing members, hardware, and accessories in accordance with approved shop drawings and the requirements specified herein. Set frames securely anchored in place to straight, plumb, square, level condition without distortion and in alignment. Install door panels to retain proper weathering contact with frames. Caulk metal-to-metal joints between frame members and remove excess material. Caulking around perimeter of door frame and wall openings to provide weathertight installation shall be accomplished in accordance with AAMA 800 and manufacturer's recommendations. Finished work shall be rigid, neat in appearance, and free from defects. Upon completion, adjust sliding doors to operate properly. Thoroughly clean aluminum frames and glass in accordance with manufacturer's recommendation. Doors damaged prior to completion and acceptance shall be restored to original manufactured condition or replaced with new doors as directed.
3.1.2 Protection of Aluminum from Dissimilar Materials
3.1.2.1 Aluminum to Dissimilar Metals
Prevent aluminum surfaces from contacting dissimilar metals other than stainless steel, zinc, or white bronze by one or a combination of the following:
a. Paint dissimilar metal with one coat of heavy-bodied bituminous paint.
b. Apply caulking between aluminum and dissimilar metal.
c. Paint dissimilar metal with primer, followed by one coat of aluminum paint or other suitable lead-free coating.
d. Use nonabsorptive tape or gasket in permanently dry locations.
3.1.2.2 Drainage from Dissimilar Metals
Paint dissimilar metals located in areas where their drainage washes over aluminum to prevent the staining of aluminum.
3.1.2.3 Aluminum to Masonry and Concrete
Prevent aluminum surfaces from coming into contact with mortar, concrete, or other masonry materials by applying one coat of heavy-bodied bituminous paint to the aluminum surfaces.
3.1.2.4 Aluminum to Wood
Prevent aluminum surfaces from coming into contact with wood, treated wood, or similarly absorptive materials by one or a combination of the following methods:
a. Paint aluminum surfaces with two coats of aluminum paint or one coat of
SECTION 08 32 13 Page 4 heavy-bodied bituminous paint.
b. Paint the wood, treated wood, or other absorptive surfaces with two coats of aluminum paint and seal contiguous joints with caulking compound.
SECTION 08 32 13 Page 5
SECTION 08 36 13
SECTIONAL OVERHEAD DOORS
08/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A227/A227M (2017) Standard Specification for Steel Wire, Cold-Drawn for Mechanical Springs
ASTM A229/A229M (2017) Standard Specification for Steel Wire, Quenched and Tempered for Mechanical Springs
ASTM A36/A36M (2014) Standard Specification for Carbon Structural Steel
ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM E330/E330M (2014) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
DOOR AND ACCESS SYSTEM MANUFACTURERS ASSOCIATION (DASMA)
ANSI/DASMA 102 (2011) Specifications for Sectional Overhead-Type Doors
ANSI/DASMA 108 (2012) Standard Method for Testing Sectional Garage Doors and Rolling Doors:
Determination of Structural Performance Under Uniform Static Air Pressure Difference
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;
TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;
TIA 17-11; TIA 17-12; TIA 17-13; TIA
17-14; TIA 17-15; TIA 17-16; TIA 17-17)
SECTION 08 36 13 Page 1
National Electrical Code
UNDERWRITERS LABORATORIES (UL)
UL 325 (2017) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems
1.2 SUBMITTALS
Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES.
SD-02 Shop Drawings
Doors; G
Show types, sizes, locations, metal gages including minimum metal decimal thickness, coating, hardware provisions, installation details, and other details of construction.
SD-03 Product Data
Doors; G Electric operators; G
For electrically motor-operated doors, submit manufacturer's wiring diagrams for motor and controls.
SD-08 Manufacturer's Instructions
Doors
SD-10 Operation and Maintenance Data
Doors; G
Submit Data Package 2 in accordance with Section 01 78 23
OPERATION AND MAINTENANCE DATA.
1.3 DELIVERY, STORAGE, AND HANDLING
Protect doors and accessories from damage during delivery, storage, and handling. Clearly mark manufacturer's brand name. Store doors in dry locations with adequate ventilation, free from dust and water. Remove damaged items and provide new. Provide easy access for inspection and handling of overhead doors prior to installation.
1.4 WARRANTY
Provide limited lifetime warranty on materials and hardware. Provide minimum 5 year warranty against polyurethane delamination from steel face, and minimum 5 year finish warranty.
1.5 QUALITY ASSURANCE
Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum five years documented experience.
SECTION 08 36 13 Page 2
Installer Qualifications: Authorized representative of the manufacturer with minimum five years documented experience
Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. acceptable to authority having jurisdiction as suitable for purpose specified.
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Hard-Drawn Springwire
ASTM A227/A227M.
2.1.2 Oil-Tempered Springwire
ASTM A229/A229M.
2.1.3 Steel Sheet
ASTM A653/A653M.
2.1.4 Steel Shapes
ASTM A36/A36M.
2.1.5 Glass
Provide double strength, clear tempered glass 1/4 inch thick.
2.2 DOORS
Metal doors shall comply with ANSI/DASMA 102. Metal doors to have horizontal sections hinged together which operate in a system of tracks to completely close the door opening in the closed position and make the full width and height of the door opening available for use in the open position. Provide a permanent label on the door indicating the name and address of the manufacturer. Doors operate by lifting handles and by electric power. Basis of Design is Wayne-Dalton 9100/9605 series - Ranch style white with Stockbridge IV windows or Overhead Door Company Courtyard Collection for CSM and GO homes. Provide Spear decorative hardwire. Provide lifetime warranty.
2.3 DESIGN REQUIREMENTS
Design wind load shall conform to the design wind load for the building of door area without damage. Doors shall be tested in accordance with either ASTM E330/E330M or ANSI/DASMA 108 and shall meet the acceptance criteria of
ANSI/DASMA 108.
2.4 FABRICATION
2.4.1 Doors
Form 1-1/2" inch nominal thickness door sections of hot-dipped galvanized, powder-coated steel not lighter than 0.012 inches, on each side of longitudinal integral reinforcing ribs. Provide sections of the height and
SECTION 08 36 13 Page 3 width indicated in the drawings. Provide glass panels and install panels using manufacturer's standard rubber gaskets. Door panel sections shall be pinch resistant and have end-cap closures.
2.4.2 Tracks
Provide galvanized steel tracks not lighter than 14 gage thick for 2 inch tracks and not lighter than 12 gage thick for 3 inch tracks. Provide galvanized steel vertical tracks with continuous galvanized steel angle not lighter than 13 gage for installation to walls. Incline vertical track through use of adjustable brackets to obtain a weathertight closure at jambs. Reinforce horizontal track with galvanized steel angle; support from track ceiling construction with galvanized steel angle and cross bracing to provide a rigid installation.
2.4.3 Hardware
Provide hinges, brackets, nylon rollers, locking devices, and other hardware required for complete installation. Install roller brackets and hinges with 14 gage galvanized steel. Provide rollers with ball bearings and case-hardened races. Provide reinforcing on doors where roller hinges are connected. Provide a positive locking device and cylinder lock with two keys on manually operated doors. Provide manual handles and pull string to disengage motor from driver in the event of power failure.
2.4.4 Counterbalancing
Counterbalance doors with an oil-tempered, helical-wound torsional spring mounted on a steel shaft. Provide adjustable spring tension, connect spring to doors with cable through cable drums. Provide cable safety factor of at least 5 to 1.
2.5 ELECTRIC OPERATORS
2.5.1 Operator Features
Operators shall be labeled and listed to the requirements of UL 325 and the Consumer Protection Safety Commission and include safety devices, motion detector lighting, and access security system.
2.5.2 Motors
Provide belt driven motor, not less than 1/2 HP, with opening speed of 10" per second and dual frequency.
2.5.3 Controls
Locate dual frequency 3-button control switch at ADA mounting height at locations within garage next to man door entering into conditioned space, so the operator will have complete visibility of the door at all times.
Provide 2 additional portable battery operated controllers.
2.5.4 Entrapment Protection Devices
Entrapment protection devicesshall be provided for electrically-operated doors in accordance with UL 325. These devices shall immediately stop and reverse the door in its closing travel upon sensing an obstruction in the door opening or upon failure of the device or any component of the control system.
SECTION 08 36 13 Page 4
2.5.5 Electrical Components
NFPA 70. Furnish automatic control and safety devices. Conduit wiring and mounting of controls are specified in the corresponding electrical specification section.
2.6 WEATHER SEALS
Provide exterior doors with weatherproof interlocking joints between sections by means of tongue-and-groove joints, rabbetted joints, shiplap joints, or wool pile, vinyl or rubber weatherstripping; a rubber, or vinyl adjustable weatherstrip at the top and jambs. Provide compressible neoprene or rubber weather seal attached to the bottom of the door.
2.7 FINISHES
2.7.1 Steel
Provide a zinc coating on all steel surfaces, a phosphate treatment, and a shop prime coat of rust-inhibitive paint. Conform to ASTM A653/A653M for galvanized coating, coating designation G60, for steel sheets, and ASTM A123/A123M for assembled steel products. The weight of coatings for assembled products shall be as designated in Table I of ASTM A123/A123M for the class of material to be coated. Provide a prime coat as requried especially developed for materials treated by phosphates and adapted to application by dipping or spraying. Repair damaged zinc-coated surfaces with galvanizing repair paint and spot prime. Prepare all steel in accordance with ASTM D7803 in preparation for 2-coat baked on powder-coated finish.
Provide coating meeting all performance requirements of AAMA 2604.
PART 3 EXECUTION
3.1 EXAMINATION
Do not begin installation until openings and substrates have been properly prepared. Verify wall openings are ready to receive work and opening dimensions and tolerances are within specified limits. Verify electric power is available and of correct characteristics.
3.2 PREPARATION
Clean surfaces thoroughly prior to installation. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
3.3 INSTALLATION
NFPA 70. Install doors in accordance with approved shop drawings and manufacturer's written installation instructions. Securely brace door tracks suspended from structure, securing tracks to structural members only. Lubricate and adjust doors to operate freely. Provide a weathertight installation and free from warp, twist, or distortion. Provide all items and accessories for a complete installation in every respect.
SECTION 08 36 13 Page 5
3.3.1 CLEANING AND ADJUSTING
Adjust door assembly to smooth operation and in full contact with weatherstripping. Clean doors, frames and glass. Remove temporary labels and visible markings. Apply touch up paint as needed.
3.4 ELECTRICAL WORK
NFPA 70. Conduit, wiring, and mounting of controls.
3.5 TESTING
After installation is complete, operate doors to demonstrate installation and function of operators, safety features, and controls. Correct deficiencies.
3.6 PROTECTION
Do not permit construction traffic through overhead door openings after adjustment and cleaning. Protect installed products until completion of project. Touch-up, damaged coatings and finishes and repair minor damage before Substantial Completion.
SECTION 08 36 13 Page 6
SECTION 08 53 00
VINYL WINDOWS
08/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA/WDMA/CSA 101/I.S.2/A440 (2011; Update 1 2014) North American Fenestration Standard/Specification for Windows, Doors, and Skylights
ASTM INTERNATIONAL (ASTM)
ASTM D3656/D3656M (2013) Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass Yarns
ASTM F2090 (2017) Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms
WINDOW COVERING MANUFACTURERS ASSOCIATION (WCMA)
ANSI/WCMA A100.1 (2018) American National Standard for Safety of Window Covering Products
U.S. DEPARTMENT OF ENERGY (DOE)
Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System (FEMP)
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Windows; G
Indicate elevations of windows, full-size sections, thicknesses , reinforcing members, fastenings, proposed method of anchoring, size and spacing of anchors, details of construction, method of glazing, details of operating hardware, mullion details, method and materials for weatherstripping, method of attaching screens, material and method of attaching subframes, fins, stools, casings, sills, trim, window cleaner anchors, accessories, installation details, window flashings and other related items.
SECTION 08 53 00 Page 1
Schedule of Windows; G
Submit with drawings indicating location of each window unit.
SD-03 Product Data
Windows; G
Energy Star Label for All Residential Windows
Fasteners
Hardware
Screens
Weatherstripping
Accessories
Adhesives
SD-04 Samples
Windows; G
Submit one full-size window of each type, complete with certification label indicating conformance to AAMA/WDMA/CSA 101/I.S.2/A440, glazing, hardware, fins, anchors, and other accessories. Where screens or weatherstripping are required, fit sample windows with such items that are to be provided. After approval, install each sample in the work, clearly identified, and record its location.
SD-06 Test Reports
Windows; G
Submit for each window type attesting that identical or larger windows have been tested and meet the requirements specified herein for conformance to AAMA/WDMA/CSA 101/I.S.2/A440 and the specified minimum Condensation Resistance Factor (CRF).
SD-10 Operation and Maintenance Data
Windows, Data Package 1; G
Plastic Identification
When not labeled, identify types in Operation and Maintenance Manual.
1.3 QUALITY ASSURANCE
1.3.1 Labels
Each window unit must bear a certification label from an independent, nationally recognized testing organization validating that the product
SECTION 08 53 00 Page 2 complies with AAMA/WDMA/CSA 101/I.S.2/A440 for the type, grade, and performance class specified.
1.3.2 Certification
Certified test reports attesting that the window units meet the requirements of AAMA/WDMA/CSA 101/I.S.2/A440 as specified will be acceptable in lieu of product labeling or marking.
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver windows to the project site in an undamaged condition. Use care in handling and hoisting windows during transportation and at the job site.
Store windows and components out of contact with the ground, under a weathertight covering, to prevent bending, warping, or otherwise damaging the windows. Store windows and components so they will not have to be handled at minus 20 degrees F or colder. Repair damaged windows to an "as new" condition as approved. Provide new units if windows cannot be repaired.
1.5 PROTECTION
Protect finished surfaces during shipping and handling using the manufacturer's standard method, except do not apply coatings or lacquers on surfaces to receive caulking and glazing compounds.
1.6 MATERIAL IDENTIFICATION
1.6.1 Plastic Identification
Plastic products to be incorporated into the project provide product data indicating polymeric information in Operation and Maintenance Manual.
Type 1: Polyethylene Terephthalate (PET, PETE).
Type 2: High Density Polyethylene (HDPE).
Type 3: Vinyl (Polyvinyl Chloride or PVC).
Type 4: Low Density Polyethylene (LDPE).
Type 5: Polypropylene (PP).
Type 6: Polystyrene (PS).
Type 7: Other. Use of this code indicates that the package in question is made with a resin other than the six listed above, or is made of more than one resin listed above, and used in a multi-layer combination.
PART 2 PRODUCTS
2.1 GENERAL REQUIREMENTS FOR WINDOWS
Provide windows conforming to AAMA/WDMA/CSA 101/I.S.2/A440 and to requirements specified herein. Provide windows of materials, types, grades, performance classes, combinations and sizes indicated or specified.
Provide each window as a unit consisting of subframe, frame, sash, glass, hardware, mullions, fins, trim, casing, screen, weatherstripping, anchors and accessories complete. Design windows to accommodate glass, hardware, screens, weatherstripping, and accessories to be furnished.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .