SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME 2
SHEET ID. SHEET ID.TITLE TITLE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN55112_PROJ_R18_K6ENDKRW.rvt
8/13/2018 6:42:01 AM
AU
G
U
ST
W
2H N
R
XX
X
YY
Y
Au th or
XX
X
YY
Y
C
AT
C O
D E
G-002
IN
D
EX
O
F D
R
AW
IN
G
S
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
MI808 ERV-01 CONTROL POINTS SCHEDULE
MI809 COMPUTER ROOM AIR CONDITIONER (CRAC) CONTROLS
MI810 MISCELLANEOUS CONTROL SCHEMATICS
MI811 MISCELLANEOUS SEQUENCES OF OPERATION
MI812 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI813 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI814 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI815 MISCELLANEOUS CONTROL POINTS SCHEDULES
MI816 BOILER CONTROL SCHEMATIC AND SEQUENCE OF OPERATION
MI817 BOILER CONTROL POINTS SCHEDULE
MI818 CHILLER CONTROL SCHEMATIC
MI819 CHILLER CONTROL SEQUENCE OF OPERATION
MI820 CHILLER CONTROL POINTS SCHEDULE
MI821 DOM. WATER CONTROL SCHEMATIC, SEQUENCE OF OPERATION, & CONTROL POINTS SCHEDULE
MP101 HVAC HYDR. PIPING FIRST FLOOR & MECHANICAL EQUIPMENT PLATFORM FLOOR PLANS
MP102 HVAC HYDRONIC PIPING SECOND, THIRD, FOURTH AND FIFTH FLOOR PLANS
MP103 HVAC HYDRONIC PIPING SIXTH, SEVENTH, EIGHTH AND NINTH FLOOR PLANS
MP104 HVAC HYDRONIC PIPING TENTH FLOOR PLAN
E-001 ELECTRICAL LEGEND
EG101 LIGHTNING PROTECTION PLAN
EG102 GROUNDING PLANS
EG103 SIGNAL REFERENCE GROUND - CAB RAISED ACCESS FLOOR
EG501 LIGHTNING PROTECTION DETAIL
EG502 LIGHTNING PROTECTION AND GROUNDING DETAILS
EG503 GROUNDING DETAILS
EG504 GROUNDING DETAILS
EL101 LIGHTING PLANS
EL102 LIGHTING PLANS
EL103 LIGHTING PLANS
EL104 LIGHTING PLANS
EL401 CAB STAIRWELL LIGHT DETAILS
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL502 LIGHT FIXTURE DETAILS
EL601 LIGHTING CONTROL STRATEGIES AND DETAILS
EP101 POWER PLANS
EP102 POWER PLANS
EP103 POWER PLANS
EP104 POWER PLANS
EP105 POWER PLANS
EP106 POWER PLANS
EP107 POWER PLANS
EP501 ELECTRICAL DETAILS
EP601 POWER RISER DIAGRAM
EP602 FEEDER & TRANSFORMER SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 PANEL SCHEDULES
EP606 PANEL SCHEDULES
EY101 SPECIAL SYSTEMS PLANS
EY102 SPECIAL SYSTEMS PLANS
EY103 SPECIAL SYSTEMS PLANS
EY501 SPECIAL SYSTEMS DETAILS
EY601 SPECIAL SYSTEMS RISER DIAGRAMS
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
T-101 COMMUNICATIONS PLANS
T-102 COMMUNICATIONS PLANS
T-103 COMMUNICATIONS PLANS
T-401 ENLARGED COMMUNICATIONS PLANS
T-501 COMMUNICATIONS DETAILS - CABLE TRAYS
T-502 COMMUNICATIONS DETAILS
T-601 COMMUNICATIONS RISER DIAGRAMS
T-602 COMMUNICATIONS ROOM RISER DIAGRAM
I-111 FURNITURE PLAN
I-121 SIGNAGE PLAN & DETAILS
I-511 SIGNAGE TYPICALS
I-611 ROOM FINISH SCHEDULE
I-621 FINISH LEGEND
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
FA101 FIRE ALARM AND MNS FLOOR PLANS
FA102 FIRE ALARM AND MNS FLOOR PLANS
FA103 FIRE ALARM AND MNS FLOOR PLANS
FA104 FIRE ALARM AND MNS FLOOR PLANS
FA601 FIRE ALARM AND MNS DIAGRAM
FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FX101 FIRE PROTECTION 1ST AND SECOND FLOOR PLANS
FX102 FIRE PROTECTION - TOWER FLOORS 3 THRU 7
FX103 FIRE PROTECTION - TOWER FLOORS 8 THRU 12
FX301 STANDPIPE/SPRINKLER RISER SECTIONS
FX501 FIRE PROTECTION DETAILS I
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS III
P-001 PLUMBING LEGEND
PL101 PLUMBING FLOOR PLAN -1ST AND MECHANICAL EQUIPMENT PLATFORM FLOOR
PL102 PLUMBING FLOOR PLAN - 2ND AND 3RD FLOOR
PL103 PLUMBING FLOOR PLAN - 4TH AND 5TH FLOOR
PL104 PLUMBING FLOOR PLAN - 6TH AND 7TH FLOOR
PL105 PLUMBING FLOOR PLAN - 8TH AND 9TH FLOOR
PL106 PLUMBING FLOOR PLAN - 10TH FOOR AND CATWALK
PL301 PLUMBING BUILDING SECTION
PL401 PLUMBING ENLARGED PLANS
PL501 PLUMBING DETAILS
PL502 PLUMBING DETAILS
PL503 PLUMBING DETAILS
PL504 PLUMBING DETAILS
PL505 PLUMBING DETAILS
PL601 PLUMBING SCHEDULES
PL901 RISER DIAGRAMS
M-001 HVAC LEGEND
MH101 HVAC DUCTWORK FIRST FLOOR & MECHANICAL EQUIPMENT PLATFORM FLOOR PLANS
MH102 HVAC DUCTWORK SECOND, THIRD, FOURTH AND FIFTH FLOOR PLANS
MH103 HVAC DUCTWORK SIXTH, SEVENTH, EIGHTH AND NINTH FLOOR PLANS
MH104 HVAC DUCTWORK TENTH AND ELEVENTH FLOOR PLANS
MH111 HVAC THERMOSTAT, HUMIDISTAT & SENSOR FIRST & MECH EQ PLATFORM FLOOR PLANS
MH112 HVAC THERMOSTAT, HUMIDISTAT & SENSOR SECOND, THIRD, FOURTH & FIFTH FLOOR PLANS MH113 HVAC THERMOSTAT, HUMIDISTAT & SENSOR SIXTH, SEVENTH, EIGHTH & NINTH FLOOR PLANS
MH114 HVAC THERMOSTAT, HUMIDISTAT & SENSOR TENTH & ELEVENTH FLOOR PLANS
MH301 HVAC SECTIONS I
MH302 HVAC SECTIONS II
MH303 HVAC SECTIONS III
MH401 HVAC ENLARGED PLANS
MH402 HVAC ENLARGED PLANS
MH403 HVAC ENLARGED PIPING PLANS
MH501 HVAC DETAILS I
MH502 HVAC DETAILS II
MH503 HVAC DETAILS III
MH504 HVAC DETAILS IV
MH505 HVAC DETAILS V
MH506 HVAC DETAILS VI
MH507 HVAC DETAILS VII
MH508 HVAC DETAILS VIII
MH509 HVAC DETAILS IX
MH601 HVAC SCHEDULES I
MH602 HVAC SCHEDULES II
MH603 HVAC SCHEDULES III
MH701 HYDRONIC CHILLED WATER PIPING SCHEMATIC I
MH702 HYDRONIC CHILLED WATER PIPING SCHEMATIC II
MH703 HYDRONIC HOT WATER PIPING SCHEMATIC I
MH704 HYDRONIC HOT WATER PIPING SCHEMATIC II
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS GENERAL NOTES
MI003 HVAC CONTROLS SCHEDULING INSTRUCTIONS
MI801 FCU-01 THRU FCU-07 CONTROLS
MI802 FCU-08 AND FCU-09 CONTROLS
MI803 FCU-08 AND FCU-09 CONTROL POINTS SCHEDULE
MI804 ERV-01 CONTROL SCHEMATIC
MI805 ERV-01 CONTROL LADDER DIAGRAM
MI806 ERV-01 CONTROL LOGIC DIAGRAMS
MI807 ERV-01 CONTROL SEQUENCE OF OPERATION AND CONTROL SCHEDULE
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS
G-003 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
SB101 FOUNDATION PLAN & GROUND FLOOR PLAN
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB503 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SF101 MECH_EQUIPMENT_PLATFORM & 2nd FLOOR FRAMING PLAN
SF106 3RD THRU 10TH FLOOR AND CAT WALK FRAMING
SF107 11TH FLOOR AND ROOF FRAMING PLAN
SF201 FRAMING ELEVATIONS
SF301 FRAMING SECTIONS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
SF503 FRAMING DETAILS
SF504 FRAMING DETAILS
SF505 FRAMING DETAILS
SF506 FRAMING DETAILS
SF511 ROOF FRAMING DETAILS
SF512 ROOF FRAMING DETAILS
A-001 ARCHITECTURAL LEGEND & GENERAL NOTES
A-002 LIFE SAFETY CRITERIA
A-003 LIFE SAFETY PLANS (FLOORS 1-6)
A-004 LIFE SAFETY PLANS (FLOORS 7-11)
A-101 FIRST AND MECHANICAL EQUIPMENT PLATFORM FLOOR PLANS
A-102 SECOND AND THIRD FLOOR PLANS
A-103 FOURTH AND FIFTH FLOOR PLANS
A-104 SIXTH AND SEVENTH FLOOR PLANS
A-105 EIGHTH AND NINTH FLOOR PLANS
A-106 TENTH AND CATWALK FLOOR PLANS
A-107 ELEVENTH (CAB) FLOOR PLAN
A-108 REFLECTED CEILING PLAN - FIRST FLOOR AND MECHANICAL EQUIPMENT PLATFORM
A-109 REFLECTED CEILING PLAN - SECOND AND THIRD FLOORS
A-110 REFLECTED CEILING PLAN - FOURTH AND FIFTH FLOORS
A-111 REFLECTED CEILING PLAN - SIXTH AND SEVENTH FLOORS
A-112 REFLECTED CEILING PLAN - EIGHTH AND NINTH FLOORS
A-113 REFLECTED CEILING PLAN - TENTH AND CAB FLOORS
A-114 ENLARGED CONTROL TOWER CAB PLAN
A-115 CAB CABINETRY DETAILS I
A-120 ROOF PLAN
A-201 EAST AND WEST ELEVATIONS
A-202 NORTH AND SOUTH ELEVATIONS
A-301 BUILDING CROSS SECTIONS
A-310 WALL SECTIONS
A-311 ENLARGED SECTIONS
A-312 CAB ENLARGED SECTION
A-320 WALL DETAILS I
A-321 WALL DETAILS II
A-401 ENLARGED UNIT PLANS
A-402 CASEWORK DETAILS
A-403 ENLARGED FLOOR PLANS II
A-404 ENLARGED FLOOR PLANS III
A-405 ENLARGED FLOOR PLANS IV
A-406 ENLARGED FLOOR PLANS V
A-410 STAIR PLANS AND ENLARGED SECTION
A-411 STAIR DETAILS I
A-412 STAIR DETAILS II
A-420 ENLARGED ELEVATOR PLANS AND SECTIONS
A-501 PLAN DETAILS I
A-502 PLAN DETAILS II
A-510 ROOF DETAILS
A-520 CEILING DETAILS
A-521 SECTION DETAILS
A-530 INTERIOR WALL PENETRATION DETAILS
A-531 EXTERIOR WALL PENETRATION DETAILS
A-601 PARTITION TYPES
A-602 DOOR SCHEDULE AND DETAILS
A-603 DOOR DETAILS
A-604 WINDOW DETAILS
A-605 LOUVER SCHEDULE
A-620 FINISH SCHEDULE
A-701 AIR BARRIER PLANS
A-702 AIR BARRIER SECTION BOUNDARY
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED
GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT
TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-
REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE
WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL
JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GLPLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PLPUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK
MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
R (cont) --------------------
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMRTRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED
CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL
TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMTBASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
0 GRID/COLUM
N LINE
DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBE
R
REVISION
TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
w/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION
SYMBOL
EXTERIOR ELEVATION
SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
1 View Name 1/8" = 1'-0"R101
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE
SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T-
TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY18PN55112_PROJ_R18_K6ENDKRW.rvt
8/8/2018 12:33:59 PM
AU
G
U
ST
W
2H N
R
XX
X
YY
Y
Au th or
XX
X
YY
Y
C
AT
C O
D E
G-003
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
XX
X
YY
Y
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
GENERAL NOTES:
G-1. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS. COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-2. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE AFFECTED.
G-3. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
G-4. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING
CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS
COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING,
SHEETING, TEMPORARY BRACING, GUYS, OR TIE-DOWNS.
G-5. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION.
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND
CONSTRUCTION AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, SEQUENCES, AND SAFETY.
G-6. PROVIDE TEMPORARY BRACING AND SHORING OF THE STRUCTURE AND COMPONENTS UNTIL ALL
COMPONENTS ARE ERECTED AND ALL CONNECTIONS ARE FULLY MADE, AS NECESSARY, TO
ENSURE STABILITY DURING CONSTRUCTION. BRACE ALL WALLS DURING CONSTRUCTION AGAINST
WIND AND/OR CONSTRUCTION LOADS.
G-7. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
G-8. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
CONCRETE CONSTRUCTION NOTES:
C-1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE
"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE
SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301-16) OF THE AMERICAN CONCRETE
INSTITUTE (ACI).
C-2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AND UTILIZE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (w/cm) OF 0.50.
C-3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS.
C-4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
C-5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
C-6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE SPLICED AS SHOWN IN SCHEDULE. REINFORCING
STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X BAR DIAMETER.
C-7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. SLABS AND WALLS 1"
C-8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS
SHALL CONFORM TO THE REQUIREMENTS OF ACI 318.
C-9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT VERTICAL
SURFACES.
C-10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
C-11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
C-12. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S
DESIGNATED REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING
REINFORCEMENT.
C-13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
C-14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY
COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION
BETWEEN ALUMINUM AND STEEL.
C-15. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH
GREATER THAN 1.5 TIMES THE PANEL WIDTH.
C-16. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED
TO, COLUMNS AND SLAB RECESSES.
C-17. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
DESIGN LOAD CRITERIA:
D-1 CODES:
IBC 2015 / ASCE 7-10 / UFC 3-301-01
D-2. LIVE LOADS:
ALL FLOORS (PER UFC 4-133-01) 150 PSF
RAISED ACCESS FLOOR, MOST CRITICAL LOAD OF 2000 LB OR 150PSF
CATWALKS 60 PSF
SLAB ON GRADE 150 PSF
D-3. ROOF LIVE LOAD: 20 PSF
D-4. SNOW LOADS:
MINIMUM GROUND SNOW LOAD, Pg 5 PSF SNOW EXPOSURE FACTOR, Ce 0.9 SNOW THERMAL FACTOR, Ct 1.1 SNOW IMPORTANCE FACTOR, Is 1.2 ROOF SLOPE FACTOR, Cs 1.0 FLAT ROOF SNOW LOAD, Pf 4.2 PSF
D-5. WIND LOADS:
BASIC WIND SPEED, V 120 MPH
RISK CATEGORY IV
WIND LOAD IMPORTANCE CATEGORY, Iw 1.0
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-6. COMPONENTS AND CLADDING WIND PRESSURES: SEE C&C PRESSURE
DIAGRAM ON S-002.
D-7. SEISMIC LOADS:
RISK CATEGORY IV
SEISMIC IMPORTANCE FACTOR, Ie 1.5 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.122
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.071
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.13 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.114
SEISMIC DESIGN CATEGORY C
SEISMIC-FORCE RESISTING SYSTEM ECCENTRICALLY BRACED FRAMES
RESPONSE MODIFICATION FACTOR, R 8
SYSTEM OVERSTRENGTH FACTOR 2
DEFLECTION AMPLIFICATION FACTOR, Cd 4 SEISMIC RESPONSE COEFFICIENT, Cs 0.024
SEISMIC-FORCE RESISTING SYSTEM MASONRY SHEAR WALL
RESPONSE MODIFICATION FACTOR, R 2
SYSTEM OVERSTRENGTH FACTOR 2 1/2
DEFLECTION AMPLIFICATION FACTOR, Cd 2 SEISMIC RESPONSE COEFFICIENT, Cs 0.098
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC BASE SHEAR 66 KIPS
D-8. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION PARKING AND ROADWAYS
WITHIN A CONTROLLED
PERIMETER
BUILDING CATEGORY INHABITED BUILDING
DESIGN LEVEL OF THREAT VERY LOW
DESIGN LEVEL OF PROTECTION (LOP) VERY LOW (VLOP)
CONVENTIONAL CONSTRUCTION STANDOFF 75 FT
APPLICABLE EXPLOSIVE WEIGHT CLASS II
PROGRESSIVE COLLAPSE CRITERIA APPLIES YES
SUPPORT FASTENERS
LAP
FASTENERS
METAL DECK
METAL DECK
GAUGE
MOMENT OF INERTIA OF
STEEL SECTION, Ip (IN4)
SECTION MODULUS OF
STEEL SECTION
POSITIVE BENDING, Sp
(IN3)
(METAL ROOF
DECK) - 1.5B20
MINIMUM PROPERTIES OF METAL DECK
MOMENT OF INERTIA OF
STEEL SECTION, In (IN4)
SECTION MODULUS OF
STEEL SECTION
POSITIVE BENDING, Sn
(IN3)
0.201
0.234
0.222
0.247
(COMPOSITE FLOOR
DECK) - 2VLI18
0.559
0.495
0.558
0.504
20 18
MASONRY CONSTRUCTION NOTES:
M-1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING
CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-13/ASCE 5-13/
TMS 402-13) AND "SPECIFICATION FOR MASONRY STRUCTURES" (ACI 530.1-13/
ASCE 6-13/TMS 602-13).
M-2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 2000 PSI. NET AREA
COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNITS SHALL BE A
MINIMUM OF 1900 PSI.
M-3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE
MANUFACTURED WITH NORMAL WEIGHT AGGREGATE.
M-4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES.
GROUT SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.
M-5. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM
A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN
ACCORDANCE WITH ACI 315. SHOP FABRICATE REINFORCING BARS WHICH ARE
INDICATED TO BE BENT OR HOOKED.
M-6. LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND
ADDITIONALLY AT THE TOP OF ALL FOUNDATIONS AND IN THE TWO JOINTS
IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM
OF 24 INCHES BEYOND THE JAMB ON EACH SIDE.
M-7. PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY
IN STEEL OR PVC SLEEVES OR CORED HOLES UNLESS OTHERWISE
INDICATED ON THE DRAWINGS.
M-8. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED
IN MASONRY GROUT, OR MORTAR, UNLESS EFFECTIVELY COATED OR COVERED
TO PREVENT ALUMINUM-CEMENT CHEMICAL REACTION OR ELECTROLYTIC
REACTION BETWEEN ALUMINUM AND STEEL.
M-9. UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT
IN BLOCK CELLS. USE NONMETALLIC BAR POSITIONERS.
M-10. PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME
SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. WHERE VERTICAL
REINFORCEMENT IS NON-CONTINUOUS, PROVIDE SPLICE LENGTH AS SHOWN
IN SCHEDULE ON S-601 U.N.O. ON PLANS.
FOUNDATION AND SLAB NOTES:
F-1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT
TITLED "SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING REPORT, AIR TRAFFIC
CONTROL TOWER, FY 18, LI 55112, FT BENNING, GA", DATED *FEBUARY 2018.
F-2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON DRILLED PIERS. LOAD BEARING CAPACITY OF DRILLED PIERS IS DETERMINED AS OUTLINED IN THE GEOTECHNICAL REPORT. PIER CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI.
F-3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERETHE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE BEEN FOLLOWED AND ACCOMPLISHED.
F-4. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY
SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY
AND EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE
SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER
CONDITIONS WHICH MIGHT BE ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED
BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK, AND TO SHEET
B-301 FOR ADDITIONAL EXCAVATION REQUIREMENTS.
F-5. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
F-6. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES
INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION
WIDTHS SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
F-7. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH
ADJACENT UNDERGROUND UTILITIES.
F-8. PLACE 10 MIL VAPOR RETARDER ON 4" CAPILLARY WATER BARRIER UNDER ALL INTERIOR
SLABS-ON-GRADE (TYPICAL).
F-9 PILE FOUNDATIONS SHALL BE PLACED BASED ON THE RECOMMENDATIONS PROVIDED IN THE
GEOTECHNICAL REPORT. DRILL SHAFTS SHALL BE REINFORCED AS SHOWN IN THE FOUNDATION
DRAWINGS.
STEEL DECK NOTES CONTINUED:
SD-1. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL OTHER
ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE DECK
MANUFACTURER'S RECOMMENDATIONS.
SD-2. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
SD-3. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
SD-4. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO
SD-5. ATTACH SHEETS TO STEEL SUPPORT MEMBERS AS INDICATED AND IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. WHEN DECK IS SCHEDULED TO BE EXPOSED, DESLAG, CLEAN AND TOUCH UP WELDS WITH A ZINC RICH PRIMER.
SD-6. LAP FLOOR DECK ENDS MINIMUM OF 2 INCHES. WHEN FASTENING DECK TO SUPPORT MEMBERS, PROVIDE WELDING MATERIALS AND INSTALLATION PROCEDURES TO PREVENT BURNING OF HOLES
IN DECK.
SD-7. FORM FLOOR DECK FROM STEEL SHEETS CONFORMING TO A 653 OR HIGHER SPECIFICATIONS
WITH A MINIMUM YIELD STRENGTH OF 40 KSI.
SD-8. AT ENDS OF DECKS OR WHERE CHANGES OF DECK DIRECTION OCCUR, FASTEN TO SUPPORTS AT
EACH FLUTE. PROVIDE ADEQUATE CLOSURES AND FASTENERS TO SIDES AT 18 INCHES ON
CENTER.
SD-9. WHERE PARTIAL PANELS MAY BE REQUIRED TO COMPLETE DECK INSTALLATION AT PERIMETER OF
STRUCTURE, PROVIDE WELDS IN EACH FLUTE TO STRUCTURAL MEMBERS.
SD-10. METAL ROOF DECK:
PROVIDE POSITIVE ATTACHMENT TO FRAMING MEMBERS AS INDICATED BELOW:
a. TYPICAL -5/8 INCH DIAMETER PUDDLE WELDS AT 36/7 PATTERN.
PROVIDE #10 TEK SCREW SIDE LAP FASTENERS AS INDICATED BELOW:
a. TYPICAL - (6) CONNECTORS EQUALLY SPACED BETWEEN SUPPORTS.
SD-11. COMPOSITE METAL DECK:
a. PROVIDE ATTACHMENT TO FRAMING MEMBERS WITH 5/8 INCH DIAMETER PUDDLE
WELDS AT LAP FLUTES AND 12 INCHES ON CENTER BETWEEN THE LAP FLUTES. SHEAR STUDS
WELDED THROUGH DECK MAY REPLACE PUDDLE WELDS. POWDER ACTUATED FASTENERS HILTI
X-ENP-19 MAY BE USED TO ATTACH THE METAL DECK TO SUPPORTING STEEL ELEMENTS ON A
36/7 PATTERN.
b. PROVIDE (5) #10 TEK SCREWS SIDE LAP FASTENERS EQUALLY SPACED BETWEEN SUPPORTS.
c. PROVIDE SHEAR CONNECTORS AS INDICATED ON THE DRAWINGS
d. MAINTAIN SPECIFIED CONCRETE THICKNESS AT COLUMN LOCATIONS. SLAB THICKNESS
ELSEWHERE WILL VARY DUE TO DECK AND BEAM DEFLECTIONS MAKE ALLOWANCES AND
FURNISH MATERIALS TO CREATE SPECIFIED FLOOR ELEVATION, WITHIN SPECIFIED LIMITS.
e. PROVIDE SHEAR STUDS CONFORMING TO THE STANDARDS OF ASTM A 108, GRADES 1015-1020, WITH A MINIMUM TENSILE STRENGTH OF 60,000 PSI AUTOMATICALLY END WELD STUDS IN THE
FIELD THOUGH THE DECK IN ACCORDANCE WITH THE SHEAR STUD MANUFACTURERS
INSTRUCTIONS. MANUAL WELDING IS NOT PERMITTED.
LIGHT GAUGE STEEL NOTES:
LG-1 LIGHT GAUGE FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON
AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS.
LG-2 ALL LIGHT GAUGE MEMBERS SHOWN WITH IN THESE DRAWINGS ARE PRELIMINARY AND ARE FOR BIDING PURPOSES ONLY. CONTRACTOR SHALL VERIFY SIZES SHOWN IN THE DESIGN DOCUMENTS PRIOR TO CONSTRUCTION. IT IS THE INTENT OF THESE DRAWINGS THAT COLD FORMED WALL AND
TRUSS DESIGN BE DELEGATED.
LG-3. ALL CALCULATIONS AND DRAWINGS USED IN THIS DESIGN MUST BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER AND SUBMITTED FOR APPROVAL. IN ADDITION TO THE CALCULATIONS, THE SUBMITTAL SHALL INCLUDE DETAILS OF THE CONNECTIONS, ERECTION PLAN, LAYOUT, OUTRIGGERS, HEADERS, BRIDGING, AND BOTH TEMPORARY AND PERMANENT BRACING.
LG-4. THE CONTRACTOR SHALL SUBMIT COMPLETE PRODUCT CATALOGS FROM THE MATERIAL
MANUFACTURER FOR REVIEW PRIOR TO FABRICATION. THE CATALOGS SHALL INDICATE
QUALIFICATION, MATERIAL SPECIFICATIONS, DESIGN REFERENCES, ETC.
LG-5. ALL COLD-FORMED STEEL MEMBERS, THEIR COMPONENTS, AND CONNECTION MATERIAL SHALL BE
GALVANIZED. PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON FABRICATED AND
INSTALLED LIGHT GAUGE METAL FRAMING WITH GALVANIZING REPAIR PAINT ACCORDING TO ASTM
A780 AND/OR THE MANUFACTURER'S RECOMMENDATIONS.
LG-6. COLD-FORMED STEEL MEMBERS SHALL BE Fy=33KSI FOR MEMBERS 43 MILS (18 GA) AND Fy=50KSI
FOR MEMBERS 54 MILS (16 GA) AND HEAVIER.
LG-7. ALL WELDING OF LIGHT GAUGE STEEL SHALL COMPLY WITH AWS D1.1 AND AWS D1.3 FOR WELDING
BASE MATERIAL LESS THAN 1/8" THICK.
STEEL JOIST NOTES CONTINUED:
SJ-3 UNLESS OTHERWISE SHOWN, WELD K-SERIES JOIST TO SUPPORTING BEAMS OR BEARING
PLATES WITH 3/16 INCH FILLET WELD, 1-1/2 INCHES LONG ON EACH SIDE OF JOIST SEAT.
USE MINIMUM 2-3/4 INCH DIAMETER A325N BOLTS AT JOIST CONNECTIONS ON OR NEAREST
COLUMN LINES.
SJ-4 PROVIDE JOIST BRIDGING, SIZE, AND SPACING, IN ACCORDANCE WITH STEEL JOIST
INSTITUTE. PROVIDE SUPPLEMENTAL BRIDGING AS REQUIRED FOR NET WIND UPLIFT
CONDITION.
SJ-5 WIND UPLIFT ON ROOF IS PROVIDED ON SHEET S-002.
ROOF DEAD LOADS (LOWER MECHANICAL ROOM)
DL = 11 PSF (DOES NOT INCLUDE JOIST WEIGHT)
DL = 7 PLF (JOIST WEIGHT PER FOOT FOR 16K4)
SJ-6 JOIST SIZES AS SHOWN ON DRAWINGS ARE BASED ON GRAVITY LOAD CAPACITIES, DESIGN JOIST FOR THE GRAVITY LOAD CAPACITIES IN ADDITION TO OTHER LOADS (UPLIFT, AXIAL LOADS, CONCENTRATED LOADS, MOMENTS. ETC.) ON DRAWINGS.
SJ-7 SHOP DRAWINGS FOR JOISTS AND JOIST ACCESSORIES TO BE PREPARED BY THE JOIST
MANUFACTURERS DETAILERS.
SJ-8 SUBMIT DESIGN CALCULATIONS IN ACCORDANCE WITH STEEL JOIST INSTITUTE DESIGN
STANDARDS. SUBMIT DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER
LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED.
SJ-9 PROVIDE 2-1/2 INCH MINIMUM BEARING ON STRUCTURAL STEEL FOR K-SERIES JOISTS
OR PROVIDE BEARING LENGTHS PER STEEL JOIST INSTITUTE REQUIREMENTS UNLESS
GREATER LENGTHS ARE SHOWN ON DRAWINGS.
SJ-10 APPLY FULL DEAD LOADS TO JOIST GIRDERS PRIOR TO WELDING THE BOTTOM CHORD STRUTS
TO STABILIZER PLATES.
STEEL JOIST NOTES:
SJ-1 PROVIDE OPEN WEB, UNDERSLUNG, PARALLEL CHORD JOISTS UNLESS OTHERWISE
NOTED ON THE DRAWINGS.
SJ-2 DESIGN, FABRICATE, AND ERECT OPEN WEB STEEL JOISTS TO THE SPECIFICATIONS OF THE
STEEL JOIST INSTITUTE, LATEST ADDITION.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPSH\Documents\FY18PN55112_STRUC_R18_K6ENDPSH.rvt
8/8/2018 12:13:00 PM
AU
G
U
ST
W
2H N
R
- C
AT
C O
D E
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF
CONNECTIONS SHALL BE IN ACCORDANCE WITH THE AISC 360-10 "SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS" DATED 22 JUNE 2010 AND THE AISC 303-10
"CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES" DATED 14 APRIL, 2010.
THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN ANALYZED
AND DESIGNED USING AISC 360-10 LRFD METHOD.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE
WITH THE ABOVE-LISTED AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992, GRADE B
B. HSS HOLLOW SHAPES (50 KSI) ASTM A500, GRADE C
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM A325
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
STEEL CONSTRUCTION NOTES (CONTINUED):
S-3. IT IS THE INTENTION OF THESE DESIGN DOCUMENTS TO DELEGATE THE DESIGN OF ALL
STRUCTURAL STEEL CONNECTIONS TO A QUALIFIED REGISTERED ENGINEER. SIGNED
AND SEALED CALCULATIONS FOR CONNECTION DESIGNS SHALL BE SUBMITTED
SIMULTANEOUSLY WITH FABRICATION DRAWINGS FOR REVIEW. UNLESS NOTED
OTHERWISE ON PLANS, ALL SHEAR CONNECTIONS FOR SIMPLY SUPPORTED BEAMS
SHALL BE DESIGNED TO DEVELOP THE REACTION OF THE MAXIMUM ALLOWABLE
UNIFORM LOAD CAPACITY FOR THE BEAM SIZE AND SPAN SHOWN, ASSUMING FULL
LATERAL SUPPORT, AS TABULATED IN THE ALLOWABLE UNIFORM LOAD TABLES OF
THE AISC MANUAL, 14TH EDITION. WHERE CONNECTIONS ARE NOTED ON DRAWINGS AS
MOMENT CONNECTIONS, PROVIDE WELDS AND CONNECTIONS TO DEVELOP FULL FLEXURAL
CAPACITY OF THE LESSER MEMBER.
S-4. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL
CONFORM TO AWS STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE
NOTED. MINIMUM WELD SIZE FOR STRUCTURAL STEEL IS 3/16" FILLET, UNLESS
OTHERWISE NOTED ON PLANS. CURRENT AWS CERTIFICATIONS SHALL BE
AVAILABLE AT THE JOB SITE FOR REVIEW BY THE CONTRACTING OFFICER'S
REPRESENTATIVE.
S-5. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER
HIGH STRENGTH BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED
FOR THE CONNECTION LOADS. BEAM CONNECTIONS SHALL CONSIST OF ALL-BOLTED
DOUBLE-ANGLE CONNECTIONS UNLESS NOTED OTHERWISE. SHEAR CONNECTIONS
BETWEEN BEAMS AND HSS HOLLOW COLUMNS SHALL UTILIZE WT SECTIONS OFFSET
SUCH THAT THE CENTERLINE OF THE BEAM AND CENTERLINE OF THE COLUMN ALIGN.
S-6. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE
PERMITTED. BOLT HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING
IN THE FIELD.
S-7. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE
CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
S-8. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN
CALCULATIONS FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES.
S-9. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED
EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS,
AS INDICATED ON APPROVED SUBMITTALS, AND AS SPECIFICALLY APPROVED
ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-10. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
S-11. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE
WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT
THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND
COATED IN ACCORDANCE WITH THE STRUCTURAL STEEL AND PAINT SPECIFICATIONS.
COORDINATE ALL STEEL FINISHES WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
S-12. REFER TO SPECIFICATION 05 12 00 FOR ADDITIONAL INFORMATION.
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
EARTH FILL
GROUT
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT. CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOF EDGE OF FOUNDATION
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
EW EACH WAY
FF FINISHED FLOOR
FDN FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PEMB PRE-ENGINEERED METAL BUILDING
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
-66
ZONE
ROOF
FLIGHT CONTROL TOWER (CAB & TOWER)
COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA 1
WALL
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND
PRESSURE DIAGRAMS.
2. EDGE ZONES 'a' = 4'-0"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD
COMBINATIONS SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING
AWAY FROM THE COMPONENT AND CLADDING SURFACES.
20 SF
50 SF
100 SF
-62
-58
-54
-104
-99
-92
-87
-142
-135
-127
-120
-46
-46
-43
-41
-83
-83
-73
-67
ZONE 2 ZONE 3 ZONE 4 ZONE 5
200 SF -50 -82 -113 -59
500 SF -46 -75 -104 -50
1000 SF -46 -75 -89 -50
-40
-37
-37
-31
ZONE
ROOF
FLIGHT CONTROL TOWER (REAR LOWER CMU BUILDING)
COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA 1A
WALL
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND
PRESSURE DIAGRAMS.
2. EDGE ZONES 'a' = 3'-0"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD
COMBINATIONS SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING
AWAY FROM THE COMPONENT AND CLADDING SURFACES.
20 SF
50 SF
100 SF
-30
-29
-28
-54
-49
-44
-40
-80
-75
-68
-63
-37
-40
-40
-40
-45
-42
-38
-35
ZONE 2A ZONE 3A ZONE 4A ZONE 5A
200 SF -27 -35 -57 -32
500 SF -26 -30 -50 -28
1000 SF -25 -25 -45 -28
-40
-40
-70
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPSH\Documents\FY18PN55112_STRUC_R18_K6ENDPSH.rvt
8/8/2018 12:13:02 PM
AU
G
U
ST
W
2H N
R
- C
AT
C O
D E
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
ISSUED FOR CONSTRUCTION
5 5
5A
4 4
4A
4 4
CAB ROOF COMPONENT AND CLADDING
TOWER COMPONENT AND CLADDING
5 5 5
3 3 a a a
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
5A
1A
2A
2A
3A
3A
SPECIAL INSPECTION NOTES:
SI-1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH
IBC 2015, SECTION 1704.2.
SI-2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.2 AND TABLE 1705.2.3
SI-3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.3 AND TABLE 1705.3.
SI-4. INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2015, SECTION 1705.4.
SI-5. INSPECTIONS FOR SEISMIC RESISTANCE SHALL BE AS PER IBC 2015, SECTION 1705.12.
SI-6. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY
CONTROL (CQC) PLAN.
SI-7. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY ASSURANCE AGENCIES
TO CONDUCT SPECIAL INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY
SHALL PROVIDE REPORTS OF SPECIAL INSPECTIONS DIRECTLY TO THE
SF201
SF201
A
B
1 2
29' - 8"
WF2.0
SF201
SF201
SB501
2'-0" x 2'-0" x 2'-0" DEEP
SUMP PIT
SJ
SJ
BR-01
BR-02
BR
-0
3 BR
-0
ELEVATOR
PIT
2'
1/
4"
SB501
SB501
WF2.0
WF2.0WF2.0 WF2.0
SJ
SJ
10' - 0"
31' - 7 1/2"
10' - 2 1/8" 10' - 0" 10' - 2 1/8"
/4
9' - 6 1/2" 9' - 6 1/2"
1'
/4
SB501
SB502
WF2.0
8' - 3 5/8" 13' - 0 3/4" 8' - 3 5/8"
SJ
EQUIPMENT PAD
COORDINATE SIZE
WITH MECH/FP PLANS
(SEE DETAILS ON
SB503)
PROVIDE 3/4" RECESS
FOR WALKOFF MAT. (SEE
ARCHITECTURAL)
1'
1/
8"
1' - 5 3/8" 1' - 5 3/8"
2' - 2 1/4"
SB501
SB501
SB501
8'
1/
4" 0'
8"
0' - 8" 7' - 10 1/2"
W1
W1 W2
W1
W1
1' - 1 1/4" 1' - 1 1/4"
KEYED PLAN NOTE DECK SPAN
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
RE-ENTRANT CORNER
REINFORCEMENT
DIAGONAL BRACING
CONCRETE MASONRY UNIT (CMU)
X
X
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPSH\Documents\FY18PN55112_STRUC_R18_K6ENDPSH.rvt
8/8/2018 12:13:04 PM
AU
G
U
ST
W
2H N
R
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
SB101
FO
U
N D
AT
IO
N P
LA
N
G
R O
U N
D F
LO
O
R P
LA
N
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
C he ck er
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
FOUNDATION PLAN & GROUND FLOOR PLAN1
FOUNDATION PLAN NOTES
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
1. FOR GENERAL STRUCTURAL NOTES AND
ABBREVIATIONS, SEE S-001.
2. SEE SF-201 AND FOLLOWING FOR FRAME SECTIONS.
3. SEE SB SHEETS FOR FOUNDATION SECTIONS AND
DETAILS.
4. TOP OF CONCRETE SLAB-ON-GRADE ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM. SEE CIVIL
FOR EXACT ELEVATION.
5. WF INDICATES FOOTING FOUNDED IN SOIL WITH AN
ALLOWABLE BEARING CAPACITY OF 2,000 PSF AS DEFINED IN
THE FOUNDATION NOTES ON S-001. SEE FOOTING SCHEDULE
ON SB601
6. SEE SHEET SB502 FOR DRILLED PIER DETAILS.
7. TOP OF WALL FTG. = (-) 2'- 0" UNO.
8. SLAB-ON-GRADE SHALL CONSIST OF 6" THICK CONCRETE
REINFORCED WITH (1) LAYER OF 6X6 W4.0XW4.0 WWF
LOCATED AT TOP AND BOTTOM OF SLAB.
9. SLAB-ON-GRADE AT ALL INTERIOR CONDITIONS SHALL BE
PLACED ON 10 MIL VAPOR RETARDER ON A 4" LAYER OF
COMPACTED GRANULAR FILL.
10. PROVIDE (1) #5 X 4'-0" LONG AT TOP AND BOTTOM IN
SLAB-ON-GRADE AT ALL RE-ENTRANT CORNERS AND
WHERE A CONTROL JOINT TERMINATES AT A CONTROL
JOINT.
11. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL,
PLUMBING, AND FIRE PROTECTION DRAWINGS PRIOR TO
CONSTRUCTION OF FOOTINGS AND SLABS-ON-GRADE.
12. JOINT LOCATIONS DENOTED BY S.J. ARE DIAGRAMMATIC
ONLY AND DO NOT REPRESENT ALL JOINTS REQUIRED
FOR SLAB CONSTRUCTION. CONTRACTOR SHALL COORDINATE
SLAB-ON-GRADE REQUIREMENTS WITH SLAB-ON-GRADE
CONSTRUCTION SEQUENCING AND SLAB DETAILS ON SB503.
JOINT SPACING SHALL NOT EXCEED MAXIMUM JOINT SPACING
PER ACI REQUIREMENTS.
13. SEE SHEET SB601 FOR CMU WALL REINFORCEMENT DETAILS.
KEY PLAN NOTES
1 PROVIDE CONTROL JOINT IN CMU WHERE SHOWN, SEE 1/SF505
FOR DETAILS..
LEGEND
PLAN NORTH TRUE NORTH
2' - 2 1/4"1' - 0" RE: SEE PLAN
SLAB ON GRADE
RE: PLAN FOR
SLAB REINFORCEMENT
CONT. BULB-TYPE
WATERSTOP (TYP)
#5 @ 12" OC EACH FACE
#4 @ 12" OC EACH FACE WATERPROOFING
SEE ARCH.
MAX
2' - 0"
NOTES: CONTRACTOR TO VERIFY PIT DEPTH AND LOCATION AND SIZE OF THE SUMP WITH MANUFACTURE OF THE ELEVATOR SELECTED PRIOR TO FORMING.
NOTIFY STRUCTURAL ENGINEER IMMEDIATELY IF PIT DEPTH DOES NOT OCCUR AT -5'-10" ELEVATION
M
AX
2'
0"
4" CAPILLARY
BARRIER
10 MIL VAPOR
RETARDER
1'
0"
1' - 0"
1'
0"
SCALE: 3/4"=1'-0"
12 2
SLOPE TO
SUMP PIT
2"X4" KEY (TYP)
SLAB EDGE
BEYOND
SHAFT OPENING
1/2" DIA EXPANSION ANCHORS
@ 2'-0" OC w/5" EMBEDMENT
CONT SILL ANGLE PER
ELEVATOR MANUFACTURER
COORDINATE w/
ELEVATOR MANUFACTURER
FACE OF PIT
WALL
SCALE: 1 1/2"=1'-0"
T/CONC RE: PLAN
4X4X3/8 CONT ANGLE
WITH 3/4" DIA X 6" LONG
HEADED STUDS 18" OC
SCALE: 1 1/2"=1'-0"
T.O.F -2' - 0"
2' - 0"
4" SPLIT
FACED CMU
8" CMU
BLOCK
WALL REINF.
SEE SCHEDULE
DOWEL TO MATCH
WALL REINF.
4" CAPILLARY
BARRIER
10 MIL VAPOR
RETARDER
SLAB REINFORCEMENT
(SEE PLAN)
#4 BAR
#5 BAR @ 18"
O.C.
(3) #5 BAR
SCALE: 3/4"=1'-0"
12 2
RE: PLAN
W
SEE SCHEDULE
D
SE
E
SC
H
ED
U
LE
LONGITUDINAL BARS
(SEE SCHEDULE)
TRANSVERSE BARS
(SEE SCHEDULE)
10 MIL VAPOR RETARDER
4" CAPILLARY BARRIER
SOG (SEE PLAN)
8" CMU
4" SPLIT FACE
CMU
VERT. WALL REINF.
DOWEL TO MATCH
WALL REINF.
GROUT CAVITY
BELOW GRADE
1/2" EXP. JOINT
TOF
-2' - 0"
SCALE: 3/4"=1'-0"
12 2
RE: PLAN
TOF
-2' - 0"
SEE SCHEDULE
"W"
"D
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
SEE SCHEDULE
DOWEL TO MATCH
WALL REINFORCEMENT
WALL REINFORCEMENT
(SEE SCHEDULE)
1/2" EXP. JOINT
10 MIL VAPOR RETARDER
4" CAPILLARY BARRIER
SLAB
(SEE PLAN FOR
REINFORCEMENT)
RE: PLAN
T.O.F -2' - 0"
2' - 0"
4" SPLIT
FACED CMU
#4 BAR
4" CAPILLARY
BARRIER
10 MIL VAPOR
RETARDER
SLAB REINFORCEMENT
(SEE PLAN)
STEEL STUD
WALL
#5 BAR @ 18"
O.C.
(3) #5 BAR
SCALE: 3/4"=1'-0"
12 2
RE: PLAN
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPSH\Documents\FY18PN55112_STRUC_R18_K6ENDPSH.rvt
8/8/2018 12:13:06 PM
AU
G
U
ST
W
2H N
R
- C
AT
C O
D E
SB501
FO
U
N D
AT
IO
N D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
ISSUED FOR CONSTRUCTION
ELEVATOR PIT1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
DETAIL AT ELEVATOR DOOR2
TYPICAL ELEVATOR SILL SECTION3
THICKENED SLAB EDGE5 EXTERIOR WALL FOOTING6 FOOTING AT INTERIOR CMU WALL7SLAB EDGE & LIGHT GUAGE WALL4
SCALE: 3/4"=1'-0"
12 2
CL
CL
(3) #4 BAR @ 2 1/2"
O.C.TOP, REMAINDER
@ 8" O.C.
(8) #9 VERTICAL
TENSION BAR
7' -0
E M
BE
N
D M
EN
T
GUSSET BY STEEL
SUPPLIER.
#4 SPIRAL
REINFORCEMENT
@ 3" O.C.
(18) #11 VERTICAL
BAR
TOCP
-6'-0"
BOCP
-56'-0"
TYP.
7' - 0"
#8 BAR (2) LAYERS EACH
WAY. SEE PIER PLAN
VIEW
NOT TO SCALE
NOTE:
1. ANCHOR BOLTS NOT
SHOWN FOR CLARITY.
2. TOCP = TOP OF CONCRETE PIER.
3. BOCP = BOTTOM OF CONCRETE PIER.
0'
8" 0'
8"
0'
1/
2" 0'
1/ 2"
TY
P.
0'
3"
2' - 7 1/2"
2'
1/
2"
(3) LAYERS #4 BAR @
2 1/2" O.C., TOP OF
PIER, REMAINDER
@ 8" O.C.
#8 BAR (2) LAYERS
(SEE PIER PLAN AND
ELEVATION VEIW)
#9 VERTICAL TENSION
BAR
CENTER #9 TENSION BAR
NOT SHOWN FOR CLARITY.
(SEE PIER PLAN VIEW)
PIER PLAN VIEW
ANCHOR BOLT, TENSION & CAGE
REINFORCEMENT ELEVATION
NOTE:
1. SEE PIER ELEVATION VIEW
FOR REINFORCEMENT NOT
SHOWN.
2. GUSSET PLATENOT SHOWN
ON PLAN VIEW.
SPIRAL REINFORCEMENT
#4 BAR
(12) 2" DIA. F1554
ACHOR BOLT.
3'-6" EMBEDMENT
3'X3'X3" A992 GR 50
STEEL BASE PLATE
SHEAR REINFORCEMENT
#8 TIES
TENSION REINFORCEMENT
(8) #9 BAR.
(18) #11 BAR, VERTICAL BARS
0'
8" 0'
8"
0'
8"
3'X3'X3" A992 GR 50
STEEL BASE PLATE
0'
3" 0'
2"
2" GROUT PACK
BASE PLATE PLAN VIEW
0' - 8" 0' - 8" 0' - 8"
BASE PLATE EXTENSION
FOR GUSSET TYP.
SIZE AS REQUIRED
#4 TIE BAR
SEE ANCHOR
BOLT ELEV.
SCALE: 3/4"=1'-0"
12 2
0'
6" 0'
6" 0' - 6" 0' - 6"
Ld
H
2H MIN
1 NOTE:
1. REFER TO MECHANICAL, ELECTRICAL AND
CIVIL SITE DRAWINGS FOR PENETRATION
LOCATIONS AND DEPTHS. PROVIDE STEP
FOOTINGS WHERE UTILITIES ARE SHOWN
BELOW TOP OF FOOTING ELEVATIONS.
DO NOT RUN UTILITIES UNDER FOOTINGS.
2. ld = DEVELOPMENT LENGTH.
3. PENETRATIONS MUST HAVE MINIMUM 3" OF
CLEAR COVER.
4. SIZE FOOTING AS REQIURED FOR UTILITIES.
LdLd
H
2H MIN
SLAB REINFORCEMENT
RE: FOUNDATION PLAN
MATCH SLAB
REINFORCEMENT
SLAB
RE: FOUNDATION PLAN
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDPSH\Documents\FY18PN55112_STRUC_R18_K6ENDPSH.rvt
8/8/2018 12:13:08 PM
AU
G
U
ST
W
2H N
R
D es ig ne r
Au th or
Ap pr ov er
C
AT
C O
D E
SB502
FO
U
N D
AT
IO
N D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
C
IT
Sa va nn ah
, G eo rg ia
FO
R
T
BE
N N
IN
G
, G
EO
R G
IA
FL
IG
H
T C
O N
TR
O
L
TO
W
ER
PN
C he ck er
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
DRILLED PIER ELEVATION3
TOP PIER REINFORCEMENT1
TYP. STEPPED SLAB EDGE DETAIL FOR UTILITIES2
NOT TO SCALE
3/4" CHAMFER, TYP
#4 @ 12" O.C. E.W.
TOP & BOT WITH 90
DEG HOOKS AT
EACH END
FACE OF EQUIPMENT
1'
0"
1' - 0"
11'
0" 0'
6"
6" MIN.
1' - 0" (2) #5 CONT.
SUPPORT FOR
REINFORCEMENT 3'-0"
O.C. EACH WAY
4" CAPILLARY
BARRIER
CONCRETE SLAB-ON-GRADE
#5 BAR @ 12" O.C.
EACH WAY
FF
T
COMPACTED
SUBGRADE
NOTES:
1. POSITION DOWELS PERPENDICULAR
TO JOINT AND PARALLEL TO…