Range Operations Building Thies, Senegal
17 May 2019
ROOM DATA SHEETS
for the
Abbreviations ACT Acoustical Ceiling Tile CMU Concrete Masonry Unit FRP Fiberglass Reinforced Plastic GFCI Government Furnished, Contractor Installed
GFGI Government Furnished, Government Installed
NIC Not in Contract OTS Open to Structure RB Rubber Base VCT Vinyl Composition Tile WD Wood
Room 101 Entrance Vestibule
A. Summary:
Entry Vestibule
B. Function:
Controlled entry into building
C. Adjacency:
• Direct access to Corridor (102)
• Direct access to exterior
• Visual access from Open Office (103)
D. Approximate Area:
12 m2
E. Number of Occupants:
N/A
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: Plaster
• Floor Finish: Metal Entrance Grating
• Special Construction: Key Card Access Control (See Drawings)
G. Furniture, Fixtures, Equipment:
• CFCI: None
• GFGI (NIC): None
Room 102 Corridor
Corridor
B. Function:
Access to all rooms
C. Adjacency:
• Direct access to Vestibule (101)
• Direct access to all Offices (103, 108, 109, and 110)
• Direct access to Training (104)
• Direct access to Toilet rooms (105 and 106) and Janitor Closet (107)
• Direct access to exterior
D. Approximate Area:
37 m2
E. Number of Occupants:
N/A
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: Key Card Access Control (See Drawings)
G. Furniture, Fixtures, Equipment:
• CFCI: Pin Boards, 1500 W x 1250 H mm (4) Fire Extinguisher with Bracket (1)
Room 103 Open Office
Open Office
B. Function:
Open work area for personnel
C. Adjacency:
• Direct access to exterior
• Direct access to Corridor (102)
• Direct access to Secure Storage (103A)
• Visual access to Vestibule (101)
D. Approximate Area:
131 m2
E. Number of Occupants:
• 16 Full-Time Persons
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: Keycard Access Control (See Drawings)
Operable Window Coverings Window Security Bars Ceiling Fans Power/Data/Voice for all Workstations
G. Furniture, Fixtures, Equipment:
• CFCI: Marker Board, 3000 W x 1250 H mm (1) Fire Extinguisher with Bracket (1)
• GFGI (NIC): Workstations (16) Task Chairs (16) Task Lights (16) Lateral File Storage (19) Print/Copy/Fax Machine (2) Desk-Side Waste Bins (14)
Room 103A Secure Storage
Secure Storage Room
B. Function:
Secure storage room with high-security door and shelving
C. Adjacency:
• Direct access to Open Office (103)
D. Approximate Area:
12 m2
E. Number of Occupants:
N/A F. Architectural Design:
• Wall Finish: Exposed Concrete / Masonry
• Ceiling Finish: Exposed Concrete
• Floor Finish: Ceramic Tile
• Special Construction: Reinforced Concrete / Concrete Masonry
Lockable, High-Security Door G. Furniture, Fixtures, Equipment:
• CFCI: Metal Shelves, 1800 H x 1800 W x 600 D mm (3)
• GFGI (NIC): Safe (1)
Room 104 Training Room
Training room
B. Function:
Training room for office personnel
C. Adjacency:
• Direct access to Corridor (102)
• Adjacent to exterior wall
D. Approximate Area:
42 m2
E. Number of Occupants:
• 14 Transient Persons
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: STC-50 Construction
Operable Window Coverings Window Security Bars Ceiling Fans Power/Data/Voice for Conference Phone Lockable Door
G. Furniture, Fixtures, Equipment:
• CFCI: Marker Board, 3000 W x 1250 H mm (1)
• GFGI (NIC): 2-Person Tables (7) Task Chair (14)
Room 105 Women’s Toilet Room
Women’s Restroom
B. Function:
Single-user Women’s Restroom
C. Adjacency:
• Direct access to Corridor (102)
• Adjacent to Men’s Toilet (106)
• Near Janitor Closet (107)
• Near Mechanical (112)
D. Approximate Area:
5 m2
E. Number of Occupants:
• 1 Transient Person
F. Architectural Design:
• Wall Finish: Ceramic Tile
• Ceiling Finish: Plaster
• Floor Finish: Ceramic Tile
• Special Construction: Moisture Resistant Materials
Lockable Door with Occupancy Indicator G. Furniture, Fixtures, Equipment:
• CFCI: Toilet (1) ABA Grab Bars (1 Pair) Lavatory (1) Toilet Room Shelf (1) Paper Towel Dispenser (1) Soap Dispenser (1) Mirror, 800 H x 450 W mm (1) Sanitary Napkin Receptacle (1) Waste Receptacle (1) Garment Hook (1)
Room 106 Men’s Toilet Room
Men’s Restroom
B. Function:
Single-user Men’s Restroom
C. Adjacency:
• Direct Access to Corridor (102)
• Adjacent to Women’s Toilet (105)
• Near Janitor Closet (107)
• Near Mechanical (112)
D. Approximate Area:
5 m2
E. Number of Occupants:
• 1 Transient Person
F. Architectural Design:
• Wall Finish: Ceramic Tile
• Ceiling Finish: Plaster
• Floor Finish: Ceramic Tile
• Special Construction: Moisture Resistant Materials
Lockable Door with Occupancy Indicator G. Furniture, Fixtures, Equipment:
• CFCI: Toilet (1) ABA Grab Bars (1 Pair) Lavatory (1) Toilet Room Shelf (1) Paper Towel Dispenser (1) Soap Dispenser (1) Mirror, 800 H x 450 W mm (1) Waste Receptacle (1) Garment Hook (1)
Room 107 Janitor’s Closet
Janitor’s Closet
B. Function:
Janitorial and cleaning supply storage
C. Adjacency:
• Near Toilet Rooms (105 and 106)
• Near Mechanical (112)
D. Approximate Area:
7 m2
E. Number of Occupants:
N/A F. Architectural Design:
• Wall Finish: Exposed Concrete / Masonry
• Ceiling Finish: OTS
• Floor Finish: Sealed Concrete
• Special Construction: Moisture Resistant Materials
Lockable Door G. Furniture, Fixtures, Equipment:
• CFCI: Utility Sink (1) Mop Rack (1) Metal Shelves, 1800 H x 1500 W x 400 D mm (1)
Room 108 Private Office
Private Office
B. Function:
Private office
C. Adjacency:
• Direct Access to Corridor (102)
• Adjacent to Private Offices (109 and 110)
• Adjacent to exterior wall
D. Approximate Area:
17 m2
E. Number of Occupants:
• 1 Full-Time Person
• 1 Transient (Visiting) Person
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: STC-50 Construction
Operable Window Coverings Window Security Bars Ceiling Fans Lockable Door Power/Data/Voice for Workstation
G. Furniture, Fixtures, Equipment:
• CFCI: Marker Board, 1500 W x 1250 H mm (1)
• GFGI (NIC): Executive Workstation (1)
Executive Task Chair (1) Task Light (1) Lateral Files (2) Print/Copy/Fax Machine (1) Side Chairs (1)
Room 109 Private Office
Private Office
B. Function:
Private office
C. Adjacency:
• Direct Access to Corridor (102)
• Adjacent to Private Offices (108 and 110)
• Adjacent to exterior wall
D. Approximate Area:
17 m2
E. Number of Occupants:
• 1 Full-Time Person
• 1 Transient (Visiting) Person
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: STC-50 Construction
Operable Window Coverings Window Security Bars Ceiling Fans Lockable Door Power/Data/Voice for Workstation
G. Furniture, Fixtures, Equipment:
• CFCI: Marker Board, 1500 W x 1250 H mm (1)
• GFGI (NIC): Executive Workstation (1)
Executive Task Chair (1) Task Light (1) Lateral Files (2)
Room 110 Private Office
Private Office
B. Function:
Private office
C. Adjacency:
• Direct Access to Corridor (102)
• Adjacent to Private Offices (108 and 109)
• Adjacent to exterior wall
D. Approximate Area:
17 m2
E. Number of Occupants:
• 1 Full-Time Person
• 1 Transient (Visiting) Person
F. Architectural Design:
• Wall Finish: Plaster
• Ceiling Finish: ACT
• Floor Finish: Ceramic Tile
• Special Construction: STC-50 Construction
Operable Window Coverings Window Security Bars Ceiling Fans Lockable Door Power/Data/Voice for Workstation
G. Furniture, Fixtures, Equipment:
• CFCI: Marker Board, 1500 W x 1250 H mm (1)
• GFGI (NIC): Executive Workstation (1)
Executive Task Chair (1) Task Light (1) Lateral Files (2)
Room 111 Electrical Room
Electrical Room
B. Function:
Electrical service and distribution for the facility
C. Adjacency:
• Direct access from exterior
D. Approximate Area:
6 m2
E. Number of Occupants:
N/A F. Architectural Design:
• Wall Finish: Exposed Concrete / Masonry
• Ceiling Finish: OTS
• Floor Finish: Sealed Concrete
• Special Construction: None
G. Furniture, Fixtures, Equipment:
• CFCI: Fire Extinguisher with Bracket (1)
Room 112 Mechanical Room
Mechanical Room
B. Function:
Mechanical services and distribution for the facility
C. Adjacency:
• Direct access from exterior
• Adjacent to Toilet Rooms (105 and 106)
D. Approximate Area:
11 m2
E. Number of Occupants:
N/A F. Architectural Design:
• Wall Finish: Exposed Concrete / Masonry
• Ceiling Finish: OTS
• Floor Finish: Sealed Concrete
• Special Construction: None
G. Furniture, Fixtures, Equipment:
• CFCI: Fire Extinguisher with Bracket (1)
File details come from the government source that posted it.