B.08.02.07.03_Att_3_Floor_Plans.pdf

PDF 339 KB Posted

Attached to
Renovations of Fire Stations in Salcininkai and Svencionys, Lithuania
Solicitation number
W912GB19R0048
Issued by

About this file

Attachment 7.3 Floor Plans

View the file

Other files

File Type Posted
B.08.03.01_W912GB19R0048_Amendment_0001.pdf PDF
B.07.01_W912GB19R0048_PPC_Slides_2019.07.15.pdf PDF
B.07.01_Sign_In_Sheet.pdf PDF
B.08.03.01_W912GB19R0048_Amendment_0001_Conformed_Solicitation.pdf PDF
B.08.02.06.06_Att_6_Existing_Utility_Information.pdf PDF
H.08.04_Specifications.pdf PDF
B.08.02.04_Attachment_4_M_P_-_Salcininkai_Svencionys_Fire_Station_Renovations.pdf PDF
B.08.02.00_Site_Visit_Sign_in_sheet.pdf PDF
B.08.02.07.01_Att_1_Project_Location_Map.pdf PDF
B.08.02.05_Attachment_5_VAT_law_of_the_Republic_of_Lithuania.pdf PDF
B.08.02.06.04_Att_4_Structural_Calculations_Guideline.pdf PDF
B.08.02.01_Attachment_1(a)_PastPerformanceQuestionnaire.docx DOCX document
B.08.02.03_Attachment_3_BLG_Template.docx DOCX document
B.08.02.07.02_Att_2_Conceptual_Site_Plan.pdf PDF
B.08.02.06.03_Att_3_Annotated_Drawings.pdf PDF
B.08.02.07.04_Att_4_Structural_Calculations_Guideline.pdf PDF
B.08.02_W912GB19R0048.pdf PDF
B.08.02.06.01_Att_1_Project_Location_Map.pdf PDF
B.08.02.06.02_Att_2_Conceptual_Site_Plan.pdf PDF
B.08.02.07.06_Att_6_Existing_Utility_Information.pdf PDF
B.08.02.07_SECTION_011010_Statement_of_Work_Salcininkai,_Lithuania.pdf PDF
B.08.02.02_Attachment_2_BLA_Template.docx DOCX document
B.08.02.06.05_Att_5_Dedication_Plaque.pdf PDF
B.08.02.01_Attachment__1_ExperienceInfoSheet.docx DOCX document
B.08.02.06_SECTION_011010_Statement_of_Work_Svencionys,_Lithuania.pdf PDF
B.08.02.07.05_Att_5_Dedication_Plaque.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3 5

4 6

A

B

C

E

F

G

3.200 6.400 3.200 1.200

1.

3.

4.

4.

0.

3.200 6.400 0.620 3.780

UP

UP

5.8 m²

ELECTRICAL

19.1 m²

STAIR

13.6 m²

SPECIAL

CLOTHING ROOM

18.1 m²

MECHANICAL

11.2 m²

CORRIDOR

19.6 m²

BREAK

ROOM/GYM

2.7 m²

ARCHIVE

1.4 m²

LAVATORY

1.4 m²

TOILET

3.3 m²

SHOWER

009 20.3 m²

DRESSING ROOM

2.1 m²

LAUNDRY

20 20 20 20

22 22

1 : 65A-101

1 SALCININKAI FIRE AND RESCUE STATION - BASEMENT PLAN

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

BA

SE

M

EN

T

PL

AN

SA

LC

IN

IN

KA

I F

IR

E

AN

D

R

ES

C U

E

ST

AT

IO

N

SA

LC

IN

IN

KA

I, LI

TH

U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

ATTACHMENT #3: ANNOTATED DRAWINGS

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

N

# NOTE

14 DEMOLISH EXISTING DOWNSPOUT. CONSTRUCT NEW TO

DRAIN DIRECT TO NEW STORM WATER MANAGEMENT

SYSTEM.

15 DEMOLISH EXISTING ROOF DRAIN, INSTALL NEW WITH

NEW ROOF MEMBRANE.

16 DEMOLISH EXISTING PARAPET FLASHING. INSTALL NEW

METAL PARAPET CAP FLASHING.

17 EXISTING ELECTRICAL PANEL.

18 CONSTRUCT NEW ANTENNA PLATFORM. PROVIDE

CONDUIT FOR EXISTING COMMUNICATIONS CABLES

FROM ROOM 109.

19 EXCAVATE PERIMETER DRAIN AROUND FACILITY.

CONNECT TO MUNICIPAL STORM SEWER OR DRAINAGE

SWALE.

20 DEMOLISH EXISTING WINDOW AND SILL. INSTALL NEW

INSULATED WINDOW AND SILL.

21 INSTALL NEW EIFS OVER EXISTING EXTERIOR WALL

FINISHES.

22 DEMOLISH INTERIOR DOOR. PROVIDE NEW GLAZED

INTERIOR WOOD DOORS AND STEEL FRAMES.

23 DEMOLISH INTERIOR DOOR. PROVIDE NEW FLUSH PANEL

INTERIOR WOOD DOORS AND STEEL FRAMES.

24 RENOVATE EXISTING SHOWER.

# NOTE

1 EXISTING EXTERIOR STEEL CHIMNEY

2 EXISTING EXHAUST FAN

3 EXISTING PRIMARY BOILER (THERMONA THERM 55 EX/B)

4 DEMOLISH EXISTING BACKUP BOILER (SIME FAMILY) AND

PROVIDE NEW TO MATCH EXISTING PRIMARY BOILER

5 DEMOLISH EXISTING HOT WATER STORAGE TANKS (2 x

200 L) AND EXPANSION TANKS, PROVIDE NEW

6 EXISTING 36V POWER PANEL WITH SCHUKO RECEPTACLE

7 EXISTING WATER DAMAGE AND MOLD GROWTH UP TO 1.0

M ABOVE FINISHED FLOOR (TYPICAL IN BASEMENT).

DEMOLITION ALL INTERIOR FINISHES, REMOVE ALL MOLD

WITH CHEMICAL MOLDICIDE, AND INSTALL NEW FINISHES.

8 DEMOLISH WALLS AND DOOR TO COMBINE ROOMS

9 DEMOLISH EXISTING SHOWER AND INSTALL WATER

CLOSET AND LAV.

10 DEMOLISH EXISTING STEEL PIPE RADIATORS AND

INSTALL NEW EFFICIENT EQUIPMENT

11 DEMOLISH FLAT ROOF AND ANTENNA TOWER.

CONSTRUCT SLOPED HIPPED METAL ROOF

12 DEMOLISH EXISTING ROOF COVERING TO STRUCTURE.

INSTALL NEW INSULATION, ROOF MEMBRANE, AND

FLASHING.

13 DEMOLISH CAP FLASHING ON EXISTING ROOF CHIMNEYS,

INSTALL NEW.

WALLS TO BE DEMOLISHED

3 5

4 6

A

B

C

E

F

G

H

D

5.0 m²

VESTIBULE

19.8 m²

STAIR

19.6 m²

CLASSROOM

12.4 m²

KITCHEN

28.6 m²

LIVING ROOM

17.0 m²

CORRIDOR

14.9 m²

WATCH ROOM

15.1 m²

COMMUNICATIONS

12.4 m²

GUARD ROOM

15.9 m²

CORRIDOR

12.8 m²

TECHNICAL

17.9 m²

HOSE STORAGE

10.7 m²

Room

11.1 m²

HOSE DRYING

TOWER

1.4 m²

LAVATORY

1.4 m²

TOILET

226.2 m²

EQUIPMENT

GARAGE

10.8 m²

STORAGE

10.6 m²

INVENTORY

UP

UP

UP

DN

3.200 6.400 3.200 1.200 4.200

1.

3.

4.

4.

0.

3.200 6.400 0.620 3.780 4.200 21.500

.8

10 10

202020

202020

20 20 20 20

22 22

22 22

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-102

1S T

FL

O

O R

P

LA

N

SA

LC

IN

IN

KA

I F

IR

E

AN

D

R

ES

C U

E

ST

AT

IO

N

SA

LC

IN

IN

KA

I, LI

TH

U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 65A-102

1 SALCININKAI FIRE AND RESCUE STATION - 1ST FLOOR PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

N

ATTACHMENT #3: ANNOTATED DRAWINGS

# NOTE

14 DEMOLISH EXISTING DOWNSPOUT. CONSTRUCT NEW TO

DRAIN DIRECT TO NEW STORM WATER MANAGEMENT

SYSTEM.

15 DEMOLISH EXISTING ROOF DRAIN, INSTALL NEW WITH

NEW ROOF MEMBRANE.

16 DEMOLISH EXISTING PARAPET FLASHING. INSTALL NEW

METAL PARAPET CAP FLASHING.

17 EXISTING ELECTRICAL PANEL.

18 CONSTRUCT NEW ANTENNA PLATFORM. PROVIDE

CONDUIT FOR EXISTING COMMUNICATIONS CABLES

FROM ROOM 109.

19 EXCAVATE PERIMETER DRAIN AROUND FACILITY.

CONNECT TO MUNICIPAL STORM SEWER OR DRAINAGE

SWALE.

20 DEMOLISH EXISTING WINDOW AND SILL. INSTALL NEW

INSULATED WINDOW AND SILL.

21 INSTALL NEW EIFS OVER EXISTING EXTERIOR WALL

FINISHES.

22 DEMOLISH INTERIOR DOOR. PROVIDE NEW GLAZED

INTERIOR WOOD DOORS AND STEEL FRAMES.

23 DEMOLISH INTERIOR DOOR. PROVIDE NEW FLUSH PANEL

INTERIOR WOOD DOORS AND STEEL FRAMES.

24 RENOVATE EXISTING SHOWER.

# NOTE

1 EXISTING EXTERIOR STEEL CHIMNEY

2 EXISTING EXHAUST FAN

3 EXISTING PRIMARY BOILER (THERMONA THERM 55 EX/B)

4 DEMOLISH EXISTING BACKUP BOILER (SIME FAMILY) AND

PROVIDE NEW TO MATCH EXISTING PRIMARY BOILER

5 DEMOLISH EXISTING HOT WATER STORAGE TANKS (2 x

200 L) AND EXPANSION TANKS, PROVIDE NEW

6 EXISTING 36V POWER PANEL WITH SCHUKO RECEPTACLE

7 EXISTING WATER DAMAGE AND MOLD GROWTH UP TO 1.0

M ABOVE FINISHED FLOOR (TYPICAL IN BASEMENT).

DEMOLITION ALL INTERIOR FINISHES, REMOVE ALL MOLD

WITH CHEMICAL MOLDICIDE, AND INSTALL NEW FINISHES.

8 DEMOLISH WALLS AND DOOR TO COMBINE ROOMS

9 DEMOLISH EXISTING SHOWER AND INSTALL WATER

CLOSET AND LAV.

10 DEMOLISH EXISTING STEEL PIPE RADIATORS AND

INSTALL NEW EFFICIENT EQUIPMENT

11 DEMOLISH FLAT ROOF AND ANTENNA TOWER.

CONSTRUCT SLOPED HIPPED METAL ROOF

12 DEMOLISH EXISTING ROOF COVERING TO STRUCTURE.

INSTALL NEW INSULATION, ROOF MEMBRANE, AND

FLASHING.

13 DEMOLISH CAP FLASHING ON EXISTING ROOF CHIMNEYS,

3 5

4 6

A

B

C

E

F

G

H

D

19.1 m²

STAIR

16.9 m²

FIRE

DEPARTMENT

CHIEF

15.1 m²

INSPECTOR'S

OFFICE

14.6 m²

CORRIDOR

23.9 m²

BOOK KEEPING

13.6 m²

SECRETARY

4.4 m²

STORAGE

23.8 m²

INSTRUCTOR'S

OFFICE

19.8 m²

CHIEF

INSPECTOR

1.4 m²

W LAV.

1.4 m²

W WC

1.4 m²

M LAV.

1.4 m²

M WC

10.8 m²

HOSE DRYING

TOWER

5.8 m²

CASH

1.

3.

4.

4.

0.

3.200 6.400 3.200 1.200 4.200

DN

EQUIPMENT GARAGE ROOF BELOW

SEE SHEET A-105 FOR ROOF SCOPE

1202020

20 20 20 20

22 22

3.200 6.400 0.620 3.780 4.200 21.500

.8

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-103

2N D

F

LO

O R

P

LA

N

SA

LC

IN

IN

KA

I F

IR

E

AN

D

R

ES

C U

E

ST

AT

IO

N

SA

LC

IN

IN

KA

I, LI

TH

U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 65A-103

1 SALCININKAI FIRE AND RESCUE STATION - 2ND FLOOR PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

N

# NOTE

14 DEMOLISH EXISTING DOWNSPOUT. CONSTRUCT NEW TO

DRAIN DIRECT TO NEW STORM WATER MANAGEMENT

SYSTEM.

15 DEMOLISH EXISTING ROOF DRAIN, INSTALL NEW WITH

NEW ROOF MEMBRANE.

16 DEMOLISH EXISTING PARAPET FLASHING. INSTALL NEW

METAL PARAPET CAP FLASHING.

17 EXISTING ELECTRICAL PANEL.

18 CONSTRUCT NEW ANTENNA PLATFORM. PROVIDE

CONDUIT FOR EXISTING COMMUNICATIONS CABLES

FROM ROOM 109.

19 EXCAVATE PERIMETER DRAIN AROUND FACILITY.

CONNECT TO MUNICIPAL STORM SEWER OR DRAINAGE

SWALE.

20 DEMOLISH EXISTING WINDOW AND SILL. INSTALL NEW

INSULATED WINDOW AND SILL.

21 INSTALL NEW EIFS OVER EXISTING EXTERIOR WALL

FINISHES.

22 DEMOLISH INTERIOR DOOR. PROVIDE NEW GLAZED

INTERIOR WOOD DOORS AND STEEL FRAMES.

23 DEMOLISH INTERIOR DOOR. PROVIDE NEW FLUSH PANEL

INTERIOR WOOD DOORS AND STEEL FRAMES.

24 RENOVATE EXISTING SHOWER.

# NOTE

1 EXISTING EXTERIOR STEEL CHIMNEY

2 EXISTING EXHAUST FAN

3 EXISTING PRIMARY BOILER (THERMONA THERM 55 EX/B)

4 DEMOLISH EXISTING BACKUP BOILER (SIME FAMILY) AND

PROVIDE NEW TO MATCH EXISTING PRIMARY BOILER

5 DEMOLISH EXISTING HOT WATER STORAGE TANKS (2 x

200 L) AND EXPANSION TANKS, PROVIDE NEW

6 EXISTING 36V POWER PANEL WITH SCHUKO RECEPTACLE

7 EXISTING WATER DAMAGE AND MOLD GROWTH UP TO 1.0

M ABOVE FINISHED FLOOR (TYPICAL IN BASEMENT).

DEMOLITION ALL INTERIOR FINISHES, REMOVE ALL MOLD

WITH CHEMICAL MOLDICIDE, AND INSTALL NEW FINISHES.

8 DEMOLISH WALLS AND DOOR TO COMBINE ROOMS

9 DEMOLISH EXISTING SHOWER AND INSTALL WATER

CLOSET AND LAV.

10 DEMOLISH EXISTING STEEL PIPE RADIATORS AND

INSTALL NEW EFFICIENT EQUIPMENT

11 DEMOLISH FLAT ROOF AND ANTENNA TOWER.

CONSTRUCT SLOPED HIPPED METAL ROOF

12 DEMOLISH EXISTING ROOF COVERING TO STRUCTURE.

INSTALL NEW INSULATION, ROOF MEMBRANE, AND

FLASHING.

13 DEMOLISH CAP FLASHING ON EXISTING ROOF CHIMNEYS,

ATTACHMENT #3: ANNOTATED DRAWINGS

3 5

4 6

A

B

C

E

F

G

H

D

10.8 m²

HOSE DRYING

TOWER

EQUIPMENT GARAGE ROOF BELOW

SEE SHEET A-105 FOR ROOF SCOPE

ADMINISTRATIVE AREA ROOF BELOW

SEE SHEET A-105 FOR ROOF SCOPE

3.200 6.400 0.620 3.780 4.200 21.500

.8

3.200 6.400 3.200 1.200 4.200

1.

3.

4.

4.

0.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-104

3R D

F

LO

O R

P

LA

N

SA

LC

IN

IN

KA

I F

IR

E

AN

D

R

ES

C U

E

ST

AT

IO

N

SA

LC

IN

IN

KA

I, LI

TH

U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 65A-104

1 SALCININKAI FIRE AND RESCUE STATION - 3RD FLOOR PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

N

# NOTE

14 DEMOLISH EXISTING DOWNSPOUT. CONSTRUCT NEW TO

DRAIN DIRECT TO NEW STORM WATER MANAGEMENT

SYSTEM.

15 DEMOLISH EXISTING ROOF DRAIN, INSTALL NEW WITH

NEW ROOF MEMBRANE.

16 DEMOLISH EXISTING PARAPET FLASHING. INSTALL NEW

METAL PARAPET CAP FLASHING.

17 EXISTING ELECTRICAL PANEL.

18 CONSTRUCT NEW ANTENNA PLATFORM. PROVIDE

CONDUIT FOR EXISTING COMMUNICATIONS CABLES

FROM ROOM 109.

19 EXCAVATE PERIMETER DRAIN AROUND FACILITY.

CONNECT TO MUNICIPAL STORM SEWER OR DRAINAGE

SWALE.

20 DEMOLISH EXISTING WINDOW AND SILL. INSTALL NEW

INSULATED WINDOW AND SILL.

21 INSTALL NEW EIFS OVER EXISTING EXTERIOR WALL

FINISHES.

22 DEMOLISH INTERIOR DOOR. PROVIDE NEW GLAZED

INTERIOR WOOD DOORS AND STEEL FRAMES.

23 DEMOLISH INTERIOR DOOR. PROVIDE NEW FLUSH PANEL

INTERIOR WOOD DOORS AND STEEL FRAMES.

24 RENOVATE EXISTING SHOWER.

# NOTE

1 EXISTING EXTERIOR STEEL CHIMNEY

2 EXISTING EXHAUST FAN

3 EXISTING PRIMARY BOILER (THERMONA THERM 55 EX/B)

4 DEMOLISH EXISTING BACKUP BOILER (SIME FAMILY) AND

PROVIDE NEW TO MATCH EXISTING PRIMARY BOILER

5 DEMOLISH EXISTING HOT WATER STORAGE TANKS (2 x

200 L) AND EXPANSION TANKS, PROVIDE NEW

6 EXISTING 36V POWER PANEL WITH SCHUKO RECEPTACLE

7 EXISTING WATER DAMAGE AND MOLD GROWTH UP TO 1.0

M ABOVE FINISHED FLOOR (TYPICAL IN BASEMENT).

DEMOLITION ALL INTERIOR FINISHES, REMOVE ALL MOLD

WITH CHEMICAL MOLDICIDE, AND INSTALL NEW FINISHES.

8 DEMOLISH WALLS AND DOOR TO COMBINE ROOMS

9 DEMOLISH EXISTING SHOWER AND INSTALL WATER

CLOSET AND LAV.

10 DEMOLISH EXISTING STEEL PIPE RADIATORS AND

INSTALL NEW EFFICIENT EQUIPMENT

11 DEMOLISH FLAT ROOF AND ANTENNA TOWER.

CONSTRUCT SLOPED HIPPED METAL ROOF

12 DEMOLISH EXISTING ROOF COVERING TO STRUCTURE.

INSTALL NEW INSULATION, ROOF MEMBRANE, AND

FLASHING.

13 DEMOLISH CAP FLASHING ON EXISTING ROOF CHIMNEYS,

3 5

4 6

A

B

C

E

F

G

H

D

13 1313

13 13

3.200 6.400 0.620 3.780 4.200 21.500

.8

1.

3.

4.

4.

0.

3.200 6.400 3.200 1.200 4.200

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-105

R O

O F

PL

AN

SA

LC

IN

IN

KA

I F

IR

E

AN

D

R

ES

C U

E

ST

AT

IO

N

SA

LC

IN

IN

KA

I, LI

TH

U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 65A-105

1 SALCININKAI FIRE AND RESCUE STATION - ROOF PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

N

# NOTE

14 DEMOLISH EXISTING DOWNSPOUT. CONSTRUCT NEW TO

DRAIN DIRECT TO NEW STORM WATER MANAGEMENT

SYSTEM.

15 DEMOLISH EXISTING ROOF DRAIN, INSTALL NEW WITH

NEW ROOF MEMBRANE.

16 DEMOLISH EXISTING PARAPET FLASHING. INSTALL NEW

METAL PARAPET CAP FLASHING.

17 EXISTING ELECTRICAL PANEL.

18 CONSTRUCT NEW ANTENNA PLATFORM. PROVIDE

CONDUIT FOR EXISTING COMMUNICATIONS CABLES

FROM ROOM 109.

19 EXCAVATE PERIMETER DRAIN AROUND FACILITY.

CONNECT TO MUNICIPAL STORM SEWER OR DRAINAGE

SWALE.

20 DEMOLISH EXISTING WINDOW AND SILL. INSTALL NEW

INSULATED WINDOW AND SILL.

21 INSTALL NEW EIFS OVER EXISTING EXTERIOR WALL

FINISHES.

22 DEMOLISH INTERIOR DOOR. PROVIDE NEW GLAZED

INTERIOR WOOD DOORS AND STEEL FRAMES.

23 DEMOLISH INTERIOR DOOR. PROVIDE NEW FLUSH PANEL

INTERIOR WOOD DOORS AND STEEL FRAMES.

24 RENOVATE EXISTING SHOWER.

# NOTE

1 EXISTING EXTERIOR STEEL CHIMNEY

2 EXISTING EXHAUST FAN

3 EXISTING PRIMARY BOILER (THERMONA THERM 55 EX/B)

4 DEMOLISH EXISTING BACKUP BOILER (SIME FAMILY) AND

PROVIDE NEW TO MATCH EXISTING PRIMARY BOILER

5 DEMOLISH EXISTING HOT WATER STORAGE TANKS (2 x

200 L) AND EXPANSION TANKS, PROVIDE NEW

6 EXISTING 36V POWER PANEL WITH SCHUKO RECEPTACLE

7 EXISTING WATER DAMAGE AND MOLD GROWTH UP TO 1.0

M ABOVE FINISHED FLOOR (TYPICAL IN BASEMENT).

DEMOLITION ALL INTERIOR FINISHES, REMOVE ALL MOLD

WITH CHEMICAL MOLDICIDE, AND INSTALL NEW FINISHES.

8 DEMOLISH WALLS AND DOOR TO COMBINE ROOMS

9 DEMOLISH EXISTING SHOWER AND INSTALL WATER

CLOSET AND LAV.

10 DEMOLISH EXISTING STEEL PIPE RADIATORS AND

INSTALL NEW EFFICIENT EQUIPMENT

11 DEMOLISH FLAT ROOF AND ANTENNA TOWER.

CONSTRUCT SLOPED HIPPED METAL ROOF

12 DEMOLISH EXISTING ROOF COVERING TO STRUCTURE.

INSTALL NEW INSULATION, ROOF MEMBRANE, AND

FLASHING.

13 DEMOLISH CAP FLASHING ON EXISTING ROOF CHIMNEYS,

Infrastructure Emergency Medicle Vehicles option.rvt - Sheet - A-101 - BASEMENT PLAN
Sheets
A-101 - BASEMENT PLAN
A-102 - 1ST FLOOR PLAN
A-103 - 2ND FLOOR PLAN
A-104 - 3RD FLOOR PLAN
A-105 - ROOF PLAN
Infrastructure Emergency Medicle Vehicles option.rvt - Sheet - A-102 - 1ST FLOOR PLAN
Sheets
A-101 - BASEMENT PLAN
A-102 - 1ST FLOOR PLAN
A-103 - 2ND FLOOR PLAN
A-104 - 3RD FLOOR PLAN
A-105 - ROOF PLAN
Infrastructure Emergency Medicle Vehicles option.rvt - Sheet - A-103 - 2ND FLOOR PLAN
Sheets
A-101 - BASEMENT PLAN
A-102 - 1ST FLOOR PLAN
A-103 - 2ND FLOOR PLAN
A-104 - 3RD FLOOR PLAN
A-105 - ROOF PLAN
Infrastructure Emergency Medicle Vehicles option.rvt - Sheet - A-104 - 3RD FLOOR PLAN
Sheets
A-101 - BASEMENT PLAN
A-102 - 1ST FLOOR PLAN
A-103 - 2ND FLOOR PLAN
A-104 - 3RD FLOOR PLAN
A-105 - ROOF PLAN
Infrastructure Emergency Medicle Vehicles option.rvt - Sheet - A-105 - ROOF PLAN
Sheets
A-101 - BASEMENT PLAN
A-102 - 1ST FLOOR PLAN
A-103 - 2ND FLOOR PLAN
A-104 - 3RD FLOOR PLAN
A-105 - ROOF PLAN

File details come from the government source that posted it.