Amendment 0001 FMMDDM_S-102XXX.pdf

PDF 148 KB Posted

Attached to
Drayton Dam Fish Passage Mitigation Project at Drayton, ND
Solicitation number
W912ES22B0002
Issued by

About this file

This is a solicitation for a construction project to replace an existing dam with a new structure that includes a rock fish passageway. The work involves constructing a fish passage structure upstream of the existing Drayton Dam in North Dakota to improve biotic connectivity as mitigation for a flood risk management project. The new fish passage structure will maintain upstream water elevations. The existing dam will then be removed. The United States Army Corps of Engineers Engineering District St. Paul is the contracting agency. Construction will largely occur in-channel and involve demolishing the existing dam and building the new fish passage structure incorporating boulder weirs upstream and tying into the location of the existing dam downstream.

View the file

Other files

File Type Posted
Bid Abstract W912ES22B0002 Drayton Dam Fish .pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Amendment 0001 permit 1973_20220405134239.pdf PDF
SPECS Drayton Dam .pdf PDF
PLANS Drayton Dam .pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S H

E E

T R

E

IS

S U

E D

W

IT

H A

M M

E N

D M

E N

T N

O

/0

/2

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S T

P

A U

L

M

IN

N E

S O

T A

S T

P

A U

L D

IS

T

R

IC

T

F M

M D

D M

S

-1

X

X X

.D G

N

F M

M D

R A

Y T

O N

D A

M M

IT

IG

A T

IO

N

F A

R G

O

M O

O R

H E

A D

F L

O O

D R

IS

K

M A

N A

G E

M E

N T

F A

R G

O

N D

R E

D R

IV

E

R O

F T

H E

N O

R T

H R

IV

E

R B

A S

IN

E X

IS

T

IN

G

D A

M D

E M

O L

IT

IO

N

S-102

A N

S I

D

T B

S

/0

/2

N K

T S

F

A L

B

/1

/2

N A

D

N D

S P

C S

N

O R

T H

Z O

N E

-U .S

S

U R

V E

Y F

T

N A

V D

.9

B

FOUNDATION SLAB

TO TOP OF SLAB

GRADUALLY CUT NOTCH

EL.753

FOUNDATION SLAB

T

O T

O P

O F

S L

A B

R

E M

O V

E C

O N

C R

E T

E

254'-0" (EXISTING WALL WILL BE REMOVED)

E L

E V

A T

IO

N

D A

T U

M

V E

R T

IC

A

L C

O N

T R

O L

C

O O

R D

IN

A

T E

S Y

S T

E M

H

O R

IZ

O

N T

A L

C O

N T

R O

L

C O

M B

IN

E

D F

A C

T O

R

C F

G E

O

ID

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D

A T

E

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

ELEVATION

PLAN VIEW

A

SECTION

A

EAST

F L

O W

WEST

EXISTING DRAYTON DAM

SCALE: 1" = 10'-0"

0 20'10'

0 20'10'

EXISTING DRAYTON DAM

1" = 1'-0"SCALE:

SCALE: " = 1'-0"4

0 4'4' 2'

NOTES:

CONSTRUCTION, INCLUDING DEMOLITION.

WATER POOL DURING ALL PHASES OF THE PROJECTS

DEMOLITION. CONTRACTOR TO MAINTAIN THE UPSTREAM

OFFICER IS REQUIRED PRIOR TO COMMENCEMENT OF THE

OF THE EXISTING DAM. APPROVAL FROM THE CONTRACTING

1. CONTRACTOR TO PREPARE A DEMOLITION PLAN FOR REMOVAL

File details come from the government source that posted it. Updated .