10521052

1053 1053

D

D

50+00

55+00

60+00 65+00

70+00

75+00 80+00

D

E ,9

,0

E ,9

,5

E ,9

,0

E ,9

,5

N 1,192,500

N 1,192,000

N 1,191,500

N 1,191,000

EL. 1060

EL. 1055

EL. 1055

EL. 1059

EL. 1059

EL. 1055

EL. 1059

EL. 1055

EL. 1059

S E E S

H E E T C -4

W E S T S

P O

IL

A

R E

A

' C

H A

N N

E L B

O T

T O

M

EL. 1060

LIMITS OF WORK

MOTORIZED TRAIL C/L

TRAIL C/L

MULTI-USE

DIVERSION CHANNEL C/L

DRAINAGE SWALE

SWALE

DRAINAGE

TO EXIST)

(SWALE BOTTOM

4:1

TO BE RELOCATED BY OTHERS

OVERHEAD POWER LINES

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps a u t o t im e

T

IM

E

D

A T

E

F

IL

E

D

W L

W L

1WL42

WL43

WL44

WL45

GRADE TO DRAIN

5:1

5:1

5:1

5:1

5:1

5:1

GRADE TO DRAIN

G R

A D E T

O D

R A

IN

G R

A D E T

O D

R A

IN

N

PLAN VIEW

200'0 100'

SCALE IN FEET

N

KEY PLAN

NOTES:

WL41

WL40

0.15%

.1

REMOVAL LEGEND

TREE REMOVAL

13-143M

13-142M

13-141M

D48

D47 G104

G105

D49

G106

D50

G107 G108

G109

G110 G100

G101

G

D45D46 G103

REFERENCES:

CONTROL - GRADING AND TRENCH DRAIN

CONTROL - ALIGNMENTS

CONTROL - LIMITS OF WORK

GENERAL PLAN & HORIZONTAL/VERTICAL CONTROL

LEGEND & GENERAL NOTES

CONSTRUCTION DRAWING INDEX

SHEET NO:

C-604

C-602

C-601

C-001

G-005

G-003

DRAIN UPON COMPLETION.

BE LOWERED. ENSURE THAT SPOIL AREA IS GRADED TO

SHALL NOT BE CHANGED, BUT THE TOP ELEVATION SHALL

PLAN SHOWN REQUIRES MODIFICATION, THE FOOTPRINT

ALTERNATE PLACEMENT SITE IS EXERCISED. IF GRADING

VOLUME OF MATERIAL PLACED IF THE OPTION FOR THE

DUE TO LEVEL OF COMPACTION DURING PLACEMENT AND

3. GRADING OF SPOIL AREA IS APPROXIMATE AND MAY VARY

SEED AS REQUIRED ON TURF ESTABLISHMENT PLANS.

2. RESTORE SPOIL AREA WITH A MINIMUM OF 4" TOPSOIL AND

MATERIAL PLACEMENT.

1. SPOIL AREA NOT REQUIRED TO BE STRIPPED PRIOR TO

D W

G R

E V

IS

E D W

IT

H A

M E

N D

M E

N T N

O

G C

W O

C T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S T P

A U

L D

IS

T R

IC

T

S T P

A U

L

M

IN

N E

S O

T A

V

A D

N A

IS

C

E N

T E

R D

R

IV

E

A N

S I

D

St. Paul District

S T P

A U

L

M N

/0

/1

M M /D

D /Y

Y Y

Y

S E

H

R O

S E

A U F

L O

O D R

IS

K M

A N

A G

E M

E N

T

R O

S E

A U R

IV

E R

R O

S E

A U

M

IN

N E

S O

T A

M A

R K A

A N

G E

L O

S A

O /S

L S

R F

R M

U H

C -4 p ln .d g n

W A

Y N

E S

W A

M B

O L

D

C-406

R E

A C

H

D E

T A

IL

P

L A

N

W E

S T S

P O

IL

A

R E

A

D J S /D

A O

W E

S -1

-B -0

File details come from the government source that posted it. Updated .