AMD_0001_Drawings_BA1401_MINI_MART.pdf
PDF 400 KB Posted
- Solicitation number
- W912ER-18-R-0015
About this file
AMD 0001 Drawings
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
O
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
AR
M
Y
CO
RP
S
O F
EN
G
IN
EE
RS
C
KD
B
Y:
US Army Corps of Engineers ®
X
A
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 3/
/2
:4
3:
A M
3/
/2
:4 3:
A
M
PI
ER
S
ID
E M
IN
I M
AR
T
Enter District
EM
S
G W
D
R O
BE
R
T L.
F O
X, P
.E
BA
-G
I0
G N
G-011
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
EM
S
IN
DE
X O
F D
RA
W
IN
G
S
P2 -4
NS
A, B
AH
R
AI
N
G
EN
ER
AL
1:
INDEX OF DRAWINGS
GENERAL
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
GENERAL
G-000 BA1401-GI000GN COVER SHEET
G-011 BA1401-GI011GN 1 AM#1 INDEX OF DRAWINGS
G-021 BA1401-GI021GN STANDARD LEGENDS AND SYMBOLOGY
G-031 BA1401-GI031GN STANDARD ABBREVIATIONS
SITE DESIGN
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
CIVIL
C-001 BA1401--CI001LS PROJECT LOCATION AND VICINITY PLAN
C-002 BA1401--CI002LS OVERALL SITE PLAN
C-003 BA1401--CI003LS HAUL ROUTE AND CONTRACTOR LAYDOWN PLAN
C-004 BA1401--CD004PN MINI-MART DEMOLITION PLAN
C-101 BA1401--CI101PN MINI-MART SITE PLAN
C-102 BA1401--CI102PN MINI-MART PAVER PLAN
C-201 BA1401--CG201PN MINI-MART GRADING PLAN
C-202 BA1401--CG203EL MINI-MART ROAD PROFILES
C-301 BA1401--CL301PN MINI-MART LANDSCAPE PLAN BASE BID
C-401 BA1401--CU401PN MINI-MART UTILITY PLAN
C-402 BA1401--CU402EL UTILITY PROFILES
C-501 BA1401--CI501DT SIDEWALK AND PAVEMENT DETAILS
C-502 BA1401--CI502DT SIDEWALK AND PAVEMENT DETAILS
C-503 BA1401--CI503DT SITE DETAILS
C-504 BA1401--CL504DT LANDSCAPE DETAILS BASE BID
C-505 BA1401--CU505DT WATER DISTRIBUTION DETAILS
C-506 BA1401--CU506DT SANITARY SEWER DETAILS
C-601 BA1401--CL601DT MINI-MART LANDSCAPE PLAN OPTION
C-602 BA1401--CL602DT LANDSCAPE DETAILS OPTION
C-603 BA1401--CL603DT LANDSCAPE DETAILS - OPTION
C-604 BA1401--CL604DT LANDSCAPE DETAILS - OPTION
SITE ELECTRICAL
XE-101 BA1401--XE101PN MINI-MART ELECTRICAL SITE PLAN
XE-501 BA1401--XE501DT ELECTRICAL DUCTBANK DETAILS
SITE TELECOMMUNICATIONS
XT-101 BA1401--XT101PN COMMUNICATIONS PARTIAL SITE PLAN (CAB)
XT-102 BA1401--XT102PN COMMUNICATIONS PARTIAL SITE PLAN
XT-103 BA1401--XT103PN COMMUNICATIONS PARTIAL SITE PLAN
XT-104 BA1401--XT104PN COMMUNICATIONS PARTIAL SITE PLAN (MINI-MART)
XT-501 BA1401--XT501DT COMM. SITE DETAILS
XT-502 BA1401--XT502DT COMM. SITE DETAILS
XT-601 BA1401--XT601DI FIBER OSP WIRING DIAGRAM
XT-602 BA1401--XT602DI COPPER OSP WIRING DIAGRAM
BA1401A - MINI-MART
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
ARCHITECTURAL
A-100 BA1401A-A100PN LIFE SAFETY PLAN
A-101 BA1401A-A101PN FLOOR PLAN
A-102 BA1401A-A102PN REFLECTED CEILING PLAN
A-103 BA1401A-A103PN ROOF PLAN
A-104 BA1401A-A104PN FINISH PLAN
A-105 BA1401A-A105DI AIR/VAPOR BARRIER INFORMATION
A-201 BA1401A-A201EL BUILDING ELEVATIONS
A-202 BA1401A-A202EL BUILDING ELEVATIONS
A-301 BA1401A-A301SE BUILDING SECTIONS
A-302 BA1401A-A302SE WALL SECTIONS
A-303 BA1401A-A303SE WALL SECTIONS CONTD.
A-401 BA1401A-A401DT ENLARGED PLAN & INTERIOR ELEVATIONS
A-402 BA1401A-A402DT ENLARGED PLAN & INTERIOR ELEVATIONS CONTD.
A-403 BA1401A-A403DT ENLARGED PLAN & INTERIOR ELEVATIONS CONTD.
A-501 BA1401A-A501DT WALL TYPES & MOUNTING HEIGHTS
A-502 BA1401A-A502DT WALL DETAILS
A-503 BA1401A-A503DT ROOF DETAILS
A-504 BA1401A-A504DT DOOR & WINDOW DETAILS
A-505 BA1401A-A505DT EIFS DETAILS
A-506 BA1401A-A506DT CASEWORK DETAILS
A-507 BA1401A-A507DT CASEWORK DETAILS CONTD.
A-508 BA1401A-A508DT MISCELLANEOUS DETAILS
A-601 BA1401A-A601SC DOOR & WINDOW TYPES & SCHEDULES
A-602 BA1401A-A602SC FINISH SCHEDULE AND INFORMATION
INTERIORS
I-101 BA1401A-I101PN EQUIPMENT PLAN
FIRE PROTECTION
F-001 BA1401A-F001GN FIRE ALARM SYMBOLS, GENERAL NOTES AND DETAILS
F-101 BA1401A-F101PN FIRE ALARM COVERAGE PLAN
F-102 BA1401A-F102PN FIRE ALARM PLAN
F-103 BA1401A-F103PN FIRE PROTECTION PLAN
F-501 BA1401A-F501DT FIRE PROTECTION DETAILS
F-502 BA1401A-F502DT FIRE PROTECTION DETAILS
PLUMBING
P-001 BA1401A-P001GN PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS
P-101 BA1401A-P101PN PLUMBING PLAN
P-401 BA1401A-P401LS ENLARGED PLUMBING PLAN
P-501 BA1401A-P501DT PLUMBING DETAILS
P-901 BA1401A-P901IS PLUMBING RISER DIAGRAMS
MECHANICAL
M-001 BA1401A-M001GN GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
M-002 BA1401A-M002GN SEQUENCE OF OPERATIONS
M-101 BA1401A-MH101PN HVAC PLAN
M-102 BA1401A-M102PN ROOF HVAC PLAN
M-501 BA1401A-M501DT MECHANICAL DETAILS
M-502 BA1401A-M502DT MECHANICAL DETAILS
M-503 BA1401A-M503DT MECHANICAL DETAILS
M-504 BA1401A-M504DT MECHANICAL DETAILS
M-601 BA1401A-M601SC MECHANICAL SCHEDULES
ELECTRICAL
E-001 BA1401A-E001GN ELECTRICAL LEGEND, ABBREVIATION AND GENERAL NOTES
E-101 BA1401A-E101PN 1 AM#1 LIGHTING PLAN
E-102 BA1401A-E102PN 1 AM#1 POWER PLAN
E-103 BA1401A-E103PN ROOF PLAN
E-104 BA1401A-E104PN ELECTRONIC SECURITY SYSTEM (ESS)
E-501 BA1401A-E501DT ELECTRICAL DETAILS
E-502 BA1401A-E502DT LIGHTING DETAILS
E-503 BA1401A-E503DT LIGHTING DETAILS
E-504 BA1401A-E504DT LIGHTING DETAILS
E-601 BA1401A-E601DI ELECTRONIC SECURITY SYSTEM ( ESS) RISER DIAGRAM
E-602 BA1401A-E602DI ONE LINE DIAGRAM
E-603 BA1401A-E603SC PANEL SCHEDULES
E-604 BA1401A-E604SC 1 AM#1 PANEL SCHEDULES
TELECOMMUNICATIONS
T-001 BA1401A-TC001GN TELECOMMUNICATIONS STANDARD LEGEND
T-101 BA1401A-TC101PN 1 AM#1 TELECOMMUNICATIONS FLOOR PLAN
T-102 BA1401A-TC102PN TELECOMMUNICATIONS ROOF PLAN
T-103 BA1401A-TC103PN ENLARGED FLOOR PLAN / ELEVATION
T-501 BA1401A-TC501DT TELECOMMUNICATIONS DETAILS
T-502 BA1401A-TC502DT TELECOMMUNICATIONS DETAILS
T-503 BA1401A-TC503DT TELECOMMUNICATION DETAILS
T-504 BA1401A-TC504DT TELECOMMUNICATIONS DETAILS
BA1401A - MINI-MART
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-001 BA1401A-S001GN GENERAL
S-101 BA1401A-S101PN FOUNDATION/GROUND FLOOR SLAB PLAN
S-102 BA1401A-S102PN ROOF FRAMING PLAN
S-501 BA1401A-S501DT DETAILS
S-502 BA1401A-S502DT DETAILS
S-503 BA1401A-S503DT CONCRETE AND MASONRY
S-504 BA1401A-S504DT SLAB ON GRADE
S-505 BA1401A-S505DT CONCRETE WALLS
S-506 BA1401A-S506DT CONCRETE COLUMNS
S-507 BA1401A-S507DT CONCRETE BEAMS
S-508 BA1401A-S508DT CONC SLABS
S-509 BA1401A-S509DT STRUCTURAL SITEWORK AND STEEL NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
AM
EN
D
M
EN
T #1
-2
6-
PC
3 3 3 3
3 3 3 3
JL
LL
L
L
A
H
B
CC
TYPICAL FIXTURE
MARK "A"
J
J
J
J
J
J
J
J
J
J J
J
H
H H
H
F F
115A
109 104
105110
112113
103A
D
D
D
EE
E
D
LPB- 19LPB- 12
LPB- 1
LPB- 5
C
A A C a b c d a b c d To Switch aTo Switch bTo Switch c
To Switch d
E
D
E
C C
GGGGG
B
BB
C
C
C
C
C
A
H
H
H
H
LPB- 15
LPB- 11 E
LPB- 7
JBOX FOR SIGN COORDINATE
WITH ARCHITECTURAL
VEST.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
O
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
AR
M
Y
CO
RP
S
O F
EN
G
IN
EE
RS
C
KD
B
Y:
US Army Corps of Engineers ®
X
A
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5
3/
/2
:4 7:
A
M
3/
/2
:4 7:
A
M
PI
ER
S
ID
E M
IN
I-M
AR
T
-1
1-
MIDDLE EAST
DISTRICT
IA IA TH
O
M A
S W
ST
EP
H
E N
SO
N
, C H
IE
F, BU
IL
D
IN
G S
YS
TE
M S
BR
AN
C H
BA
A-
E1
PN
E-101
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
W
IN
C H
ES
TE
R , V
A M
M
LI
G
HT
IN
G P
LA
N
A
P2 -4
NS
A, B
AH
R
AI
N
M
IN
I M
AR
T1 : 100
LIGHTING PLAN
1:100
10m2m 8m6m4m0m
GENERAL NOTES:
1. FOR ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS SEE
SHEET E-001.
2.REFER TO THE LIGHTING FIXTURE SCHEDULE AND DETAILS FOR
MORE INFORMATION. SEE SHEETS E-502, E-503 AND E-504.
3.EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE CONNECTED
AHEAD OF ANY LIGHT SWITCHES AND PROTECTED WITH A CIRCUIT
BREAKER GUARD IN ACCORDANCE WITH NFPA 70.
4. UPPER CASE LETTER INDICATES FIXTURE TYPE AND LOWER
CASE LETTERS DENOTE SWITCHING ZONES.
5. MOUNT PHOTOCELL ON THE NORTH SIDE OF THE BUILDING. THE
LIGHT SWITCH SHALL BE CONNECTED AHEAD OF THE PHOTOCELL
AS A MANUAL OVERRIDE
6. LIGHT FIXTURE IN COOLER/FREEZER ARE SHALL BE INCLUDED IN
GFI PACKAGE, FIXTURE ARE SHOWN FOR INFORMATION ONLY.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
AM
EN
D
M
EN
T #1
-2
6-
37TV
RCD
TV
R
C D
WPWPWP
W P
WP
WP
W P
R C
D R
C D
TV
J
WPWPWPWPWPWPWP
TV TV TV
TV
J
J
J
J
RCD
J
J
J
J J
J J
J
J J
J J
J
J
LPA- 19
LPA- 9
LPA- 20
LPA- 18
LPA- 30
LPA- 29
LPA- 21
LPA- 27
LPA- 7
LPA- 6
LPA- 12
LPA- 3
LPA- 39
LPA- 5
LPA- 35
LPA- 26
LPA- 31
LPA- 2
LPA- 8
LPA LPB LPC
103A
109 104
105108
VEST.
115A
OFFICE
LPB- 33,35,37
EWH-1
LPB- 13
LPB- 29LPB- 22 LPB- 26 LPB- 27
LPB- 31
LPB- 30
LPB- 28
LPB- 32
LPB- 17
LPB- 24
ECB
FACP
LPB- 23
LPB- 21 LPC- 4
REFER TO GROUNDING
DETAIL #1 ON SHEET E-501
EPO
LPA- 36
LPA- 17
LPB- 9
LPA- 13
LPA- 11
LPA- 23 LPA- 22
LPA- 24
LPA- 4
LPB- 14
LPA- 32LPB- 4
LPA- 34
LPA- 37
LPA- 10
LPA- 28
LPA- 41
LPA- 16
LPA- 1
LPA- 33
LPA- 25
LPC- 1
LPC- 2
LPC- 5
LPC- 3
LPC- 6
MDP
ATS
LPB- 3
LPA- 14
LPA- 15
POWER FOR ADA
PUSH PLATE
LPB- 10
POWER FOR ADA
PUSH PLATE
POWER FOR
DOOR SWINGS
POWER FOR ADA
PUSH PLATE AND
PEDESTAL
POWER FOR
DOOR SWINGS
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
O
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
AR
M
Y
CO
RP
S
O F
EN
G
IN
EE
RS
C
KD
B
Y:
US Army Corps of Engineers ®
X
A
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5
3/
/2
:3 5:
A
M
3/
/2
:3 5:
A
M
PI
ER
S
ID
E M
IN
I-M
AR
T
-1
1-
MIDDLE EAST
DISTRICT
IA IA TH
O
M A
S W
ST
EP
H
EN
SO
N , C
H
IE
F, BU
IL
D
IN
G
S
YS
TE
M
S
BR
AN
C
H
BA
A-
E1
PN
E-102
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
W
IN
C H
ES
TE
R , V
A M
M
PO
W
ER
P
LA
N
A
P2 -4
NS
A, B
AH
R
AI
N
M
IN
I M
AR
T
1 : 100
POWER PLAN
1:100
10m2m 8m6m4m0m
GENERAL NOTES:
1. FOR ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS
SEE SHEET E-001.
2.REFER TO ONE LINE DIAGRAM AND PANEL SCHEDULES
FOR CONDUIT AND CONDUCTOR SIZES.
3. REFER TO MECHANICAL/PLUMBING DRAWINGS FOR THE
SCHEDULES AND EXACT LOCATION OF EQUIPMENT.
4. REFER TO SHEET E-602 FOR SINGLE LINE DIAGRAM.
5. THE CONTRACTOR SHALL COORDINATE THE
ELECTRICAL CONNECTIONS WITH THE NAMEPLATE
RATING OF THE ACTUAL MECHANICAL EQUIPMENT
SUPPLIED AND MODIFY THE CONDUCTORS AND
OVERCURRENT PROTECTION IF NECESSARY.
6. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS
BETWEEN SAFETY DISCONNECT SHOWN
ON THE ELECTRICAL DRAWING AND THE ASSOCIATED
MECHANICAL/PLUMBING EQUIPMENT.
7. CONTRACTOR IS TO MAKE FINAL CONNECTION WITH
ALL GOVERMENT FURNISH EQUIPMENT ONCE EQUIPMENT
IS DELIVERED.
8. CONTRACTOR TO PROVIDE POWER FOR ALL
MOTORIZED DAMPERS FROM A SPARE CIRCUIT WITHIN
THE LOCAL POWER PANEL. REFER TO THE MECHANICAL
SHEETS FOR LOCATION, QUANTITY AND SEQUENCE OF
OPERATION.
9. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE
RATED NEMA 4X STAINLESS STEEL.
10. CONTRACTOR SHALL COORDINATE THE EXACT
LOCATION AND TYPE OF CONNECTION FOR ALL
EQUIPMENT.
11. ALL TV SOCKETS SHALL BE MOUNTED 1.8 METERS AFF
NEXT TO THE TV LOCATION.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
AM
EN
D
M
EN
T #1
-2
6-
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
O
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
AR
M
Y
CO
RP
S
O F
EN
G
IN
EE
RS
C
KD
B
Y:
US Army Corps of Engineers ®
X
A
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5
3/
/2
:3 5:
A
M
3/
/2
:3 5:
A
M
PI
ER
S
ID
E M
IN
I-M
AR
T
-1
1-
MIDDLE EAST
DISTRICT
IA IA TH
O
M A
S W
ST
EP
H
EN
SO
N , C
H
IE
F, BU
IL
D
IN
G
S
YS
TE
M
S
BR
AN
C
H
BA
A-
E6
SC
E-604
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
W
IN
C H
ES
TE
R , V
A M
M
PA
NE
L
SC
HE
DU
LE
S
A
P2 -4
NS
A, B
AH
R
AI
N
M
IN
I M
AR
T
Notes:
Total 3Ph VA Load 43479 VA Socket 31470 VA 65.89% 20736 VA Total Est. Demand A: 45 A WATER HEATER 4500 VA 100.00% 4500 VA Total Connected: 60 A Motor 100 VA 125.00% 125 VA Total Estimated Demand % 75.01% Lighting 6444 VA 100.00% 6444 VA Total Est. Demand: 32339 VA HVAC 506 VA 70.00% 354 VA Total Conn Power Load: 43113 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 59 A 62 A 60 A Total VA: 14256 VA 14747 VA 14476 VA
PHASE A PHASE B PHASE C
41 Space -- -- -- 0 VA 0 VA - -- 1 20 A Spare 42 39 Space -- -- -- 0 VA 0 VA - -- 1 20 A Spare 40 37 1500 VA 0 VA - -- 1 20 A Spare 38 35 1500 VA 0 VA - -- 1 20 A Spare 36
EWH-1 32 A 3 3-#10mm², 1-#10mm², 1-#10mm² 38 1500 VA 0 VA - -- 1 20 A Spare 34
31 Vending Machine 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 2300 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 32 29 Vending Machine 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 2300 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 30 27 Vending Machine 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 2300 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 28 25 Receptacles 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 720 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 26 23 Receptacles - Barber Shop 114 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 720 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 24 21 Receptacles 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 720 VA 2300 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vending Machine 22 19 Lighting 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 970 VA 500 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vehicle Charger 20 17 Vending Machine 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 2300 VA 500 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vehicle Charger 18 15 Lighting 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 1816 VA 500 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Vehicle Charger 16 13 Receptacles - 102 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 900 VA 900 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Receptacles - 103 14 11 Lighting - Reach in Cooler 115 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 680 VA 844 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Lighting - Retail Area 103 12 9 Exterior Receptacles 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 1820 VA 500 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Automatic Doors 10 7 Lighting 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 677 VA 890 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Receptacles - Roof top 8 5 Lighting - Retail Area 103 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 640 VA 700 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Type N Exterior Light Fixtures 6 3 Receptacles - 110 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 360 VA 900 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Receptacles - Cahier 102 4 1 Lighting - Retail Area 103 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 162 VA 506 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A EF-1 2
CKT Circuit Description Trip Poles Wire Size Conduit mm A B C A B C Conduit mm Wire Size Poles Trip Circuit Description CKT
MCB Trip: 125 A Enclosure: Type 1 Frequency: 50HZ MCB Rating: 125 A Mounting: Flush Wires: 4 Mains Rating: 125 A
Supply From: MDP Phases: 3 Mains Type: 125A Location: ELEC. 113 Volts: 415/240 A.I.C. Rating: 42 AIC
Branch Panel: LPB
Notes:
Total 3Ph VA Load 8625 VA Total Est. Demand A: 11 A
Total Connected: 12 A Total Estimated Demand % 94.51%
Socket 7040 VA 100.00% 7040 VA Total Est. Demand: 8094 VA HVAC 1817 VA 70.00% 1272 VA Total Conn Power Load: 8563 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 20 A 4 A 14 A Total VA: 4585 VA 1040 VA 3000 VA
PHASE A PHASE B PHASE C
29 Space -- -- -- 0 VA 0 VA -- -- -- Space 30 27 Space -- -- -- 0 VA 0 VA -- -- -- Space 28 25 Space -- -- -- 0 VA 0 VA -- -- -- Space 26 23 Space -- -- -- 0 VA 0 VA -- -- -- Space 24 21 Space -- -- -- 0 VA 0 VA -- -- -- Space 22 19 Space -- -- -- 0 VA 0 VA -- -- -- Space 20 17 Space -- -- -- 0 VA 0 VA -- -- -- Space 18 15 Space -- -- -- 0 VA 0 VA -- -- -- Space 16 13 Space -- -- -- 0 VA 0 VA -- -- -- Space 14 11 Spare 20 A 1 -- 0 VA 0 VA -- -- -- Space 12 9 Spare 20 A 1 -- 0 VA 0 VA -- 1 20 A Spare 10 7 Split Unit /CU-4 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 1817 VA 0 VA -- 1 20 A Spare 8 5 Comm Cabinet 30 A 1 1-#6mm², 1-#6mm², 1-#6mm² 20 1500 VA 1500 VA 20 1-#6mm², 1-#6mm², 1-#6mm² 1 30 A Comm Cabinet 6 3 Dedicated - CTTV 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 500 VA 540 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A General Receptacles - Room 112 4 1 Comm Cabinet 20 A 1 1-#4mm², 1-#4mm², 1-#4mm² 20 1500 VA 1500 VA 20 1-#4mm², 1-#4mm², 1-#4mm² 1 20 A Comm Cabinet 2
CKT Circuit Description Trip Poles Wire Size Conduit mm A B C A B C Conduit mm Wire Size Poles Trip Circuit Description CKT
MCB Trip: 100 A Enclosure: Type 1 Frequency: 50HZ MCB Rating: 100 A Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: MDP Phases: 3 Mains Type: 100A Location: COMM. 112 Volts: 415/240 A.I.C. Rating: 42 AIC
Branch Panel: LPC
NOTES:
1. FOR ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS SEE
SHEET E-001.
2. ALL BRANCH CIRCUIT BREAKERS FEEDING RECEPTACLES
SHALL HAVE 30mA EARTH LEAKAGE PROTECTION UNLESS
OTHERWISE NOTED.
3. REFER TO SHEET E-501 FOR SINGLE LINE DIAGRAM.
4. PROVIDE SURGE PROTECTIVE DEVICE IN ALL PANELBOARDS
FEEDING EXTERIOR LIGHTING.
5. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL RATED NEMA
4X STAINLESS STEEL.
6. PROVIDE EMERGENCY POWER OFF SWITCH FOR
COMMUNICATIONS ROOM PANEL IN ACCORDANCE WITH NFPA 70.
1-#6mm², 1-#6mm², 1-#6mm²
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
AM
EN
D
M
EN
T #1
-2
6-
W W
W
W
W
TV
TV
TV
TVTVTV
WPWPWPWPWPWP
W
T-103
1 2 3 4 5 6
5.1 5.2
A
B
C
D
EF
G
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
O
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
AR
M
Y
CO
RP
S
O F
EN
G
IN
EE
RS
C
KD
B
Y:
US Army Corps of Engineers ®
X
A
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5
3/
/2
:3 5:
A
M
3/
/2
:3 5:
A
M
PI
ER
S
ID
E M
IN
I-M
AR
T
-1
1-
MIDDLE EAST
DISTRICT
B
BL
YT
H
E
SC
D
TH
O
M A
S W
ST
EP
H
EN
SO
N , C
H
IE
F, BU
IL
D
IN
G
S
YS
TE
M
S
BA
A-
TC
1P N
T-101
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
W
IN
C H
ES
TE
R , V
A D
IN
G
EL
S
TE
LE
CO
M
M
UN
IC
AT
IO
N
S
FL
O O
R P
LA
N
A
P2 -4
NS
A, B
AH
R
AI
N
M
IN
I M
AR
T
1 : 100
TELECOMMUNICATIONS PLAN
1. FOR LEGENDS AND ABBREVIATIONS, SEE SHEET T-001.
2. PROVIDE BACKBOARDS IN ACCORDANCE WITH TIA-569-C. BACK-
BOARDS MUST BE FIRE-RETARDANT-TREATED WOOD, BEARING
THE MANUFACTURER'S STAMP. COVER A MINIMUM OF TWO
ADJACENT WALLS WITH BACKBOARDS.
3. ROUTE TELECOM WIRING IN 25mm METAL CONDUIT TO EACH
OUTLET. OUTLETS UNDER CHECK OUT COUNTER SHALL BE
ROUTED BENEATH THE COUNTER TO THE WALL PENETRATION.
4. COORDINATE LOCATION OF ALL COMMUNICATIONS DEVICES
AND CONDUITS WITH FURNITURE PLANS.
5. HOME RUN ALL CAT6 CABLES DIRECT TO OPEN RACK #1 IN
TELECOM ROOM.
6. CONTRACTOR SHALL PROVIDE DETAILS AND/OR SHOP DRAWINGS
DESCRIBING INSTALLATION PROCESS OF TELECOM OUTLETS IN
CASHIER STAND.
GENERAL SHEET NOTES
1:100
10m2m 8m6m4m0m
KEY NOTES
1 ROUTE ONE (1) GREEN CAT 6 CABLE IN 25MM METAL CONDUIT
TO KEY NOTE LOCATION. PROVIDE DOUBLE GANG BOX WITH
BLANK COVER. PROVIDE 3M SLACK IN CABLE IN BOX AND
LEAVE CABLE UNTERMINATED.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
AM
EN
D
M
EN
T #1
-2
6-
| Sheets |
| G-011 - INDEX OF DRAWINGS |
| BA1401A - MINI MART_AM#1_n0eneia3 - Sheet - E-102 - POWER PLAN.PDF |
| Sheets |
| E-102 - POWER PLAN |
| E-604 - PANEL SCHEDULES |
| T-101 - TELECOMMUNICATIONS FLOOR PLAN |
| BA1401A - MINI MART_AM#1_n0eneia3 - Sheet - E-604 - PANEL SCHEDULES.PDF |
| Sheets |
| E-102 - POWER PLAN |
| E-604 - PANEL SCHEDULES |
| T-101 - TELECOMMUNICATIONS FLOOR PLAN |
| BA1401A - MINI MART_AM#1_n0eneia3 - Sheet - T-101 - TELECOMMUNICATIONS F....pdf |
| Sheets |
| E-102 - POWER PLAN |
| E-604 - PANEL SCHEDULES |
| T-101 - TELECOMMUNICATIONS FLOOR PLAN |
| BA1401A - MINI MART_AM#1_n0enmgwd - Sheet - E-101 - LIGHTING PLAN.pdf |
| Sheets |
| E-101 - LIGHTING PLAN |
File details come from the government source that posted it.