This amendment modifies a solicitation for construction services associated with the Comprehensive Everglades Restoration Program Biscayne Bay Coastal Wetlands - Phase I Project, L-31 Flow-way Pump Station S-709 in Miami-Dade County, Florida. The amendment revises drawing T-16 to update part numbers and descriptions for system components. The solicitation remains open with proposals due on February 14, 2020. Construction activities include installing precast concrete, sheet piles, culverts, pumps, controls, electrical systems and other items to build a new pump station and associated infrastructure. The U.S. Army Corps of Engineers Jacksonville District is the contracting agency overseeing this project in support of the Comprehensive Everglades Restoration Program.

View the file

Other files

File Type Posted
W912EP20R0002_Amendment 0003.pdf PDF
W912EP20R0002 Amendment 0002.pdf PDF
Amendment 0001, W912EP20R0002.pdf PDF
20R0002 Attendance Roster.pdf PDF
W912EP20R0002 GDR.pdf PDF
W912EP20R0002 Vol 1.pdf PDF
W912EP20R0002 Plans.pdf PDF
W912EP20R0002 Vol 2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04 EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

COMPREHENSIVE EVERGLADES RESTORATION PROGRAM, BISCAYNE COASTAL WETLANDS - PHASE I PROJECT L-31E FLOW-WAY

PUMP STATION S-709, MIAMI-DADE COUNTY, FL

A.SEE CONTINUATION SHEET FOR AMENDMENT DETAILS.

B.THE PROPOSAL DUE DATE REMAINS UNCHANGED @ FEBRUARY 14, 2020 @ 2:00 P.M. LOCAL TIME.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA 15C. DATE SIGNED 15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer) (Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912EP20R0002

X 9B. DATED (SEE ITEM 11)

17-Dec-2019

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-Feb-2020

CODE

USA ENGINEER DISTRICT, JACKSONVILLE

CONTRACTING DIVISION

701 SAN MARCO BLVD

JACKSONVILLE FL 32207-8175

W912EP 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODE CODE

EMAIL: TEL:

x

SF 30 CONTINUATION SHEET

Comprehensive Everglades Restoration Program Biscayne Bay Coastal Wetlands – Phase I Project

L-31E Flow-way Pump Station S-709 Miami-Dade County, Florida

W912EP20R0002 2 Amendment 0004

SUMMARY OF CHANGES

1. CONSTRUCTION SOLICITATION AND SPECIFICATIONS:

A. Changes are indicated by asterisks appearing before and after the line or lines where amendments have been made to the text, and pertain only to changes made by this amendment. In some cases, replacement clauses are attached to this amendment.

B. Text changes have been updated with additions noted by underlined text and deletions noted by line/cross-outs, and pertain only to changes made by this amendment. The entire section is replaced if there is any change. The Project Table of Contents and Submittal Register are replaced without underlines and cross-outs if there are changes to these documents.

2. SPECIFICATIONS:

Volume 1:

None

Volume 2:

None

3. DRAWINGS (Separate Electronic File):

A. The following are changes to the drawings. Drawings should be adequately marked to indicate that they have been changed. Drawings furnished to the Contractor in accordance with the Contract Clause entitled "CONTRACT DRAWINGS, MAPS, AND SPECIFICATIONS" will be revised to reflect the revisions made herein.

DELETE Drawing T-16 and REPLACE with the attached Drawing T-16. (The Part # for 2E has been revised and the Description for 2F has been updated.

(End of Summary of Changes)

T-16

J

H E

L B

E R

G

A

T E

L E

C O

M M

U N

IC

A T

IO

N S

S C

C S

Y S

T E

M C

O M

P O

N E

T S S

C H

E D

U L E

J

H A

W K

IN

S

G

D E

L O

A C

H

GENERAL SHEET NOTES

2T ALLEN BRADLEY 700-HK36-Z12 12 VDC RELAY

CUSTOMFURNISHED BY CONTRACTOR1N

1M SQUARE D 30 MM, TYPE K

"REMOTE", "LOCAL" PHENOLIC TAG

1-1/2"x1-1/2" WIREWAY

1-1/2" WIREWAY COVER

TAMPER SWITCH BRACKET

TAMPER SWITCH

DIN RAIL

TERMINAL BLOCK

TERMINAL BLOCK END COVER

FUSED TERMINAL BLOCK

END CLAMPS

1 AMP CIRCUIT BKR - 1 POLE

3 AMP CIRCUIT BKR - 1 POLE

5 AMP CIRCUIT BKR - 1 POLE

16 AMP CIRCUIT BKR - 1 POLE

TERMINAL STRIP MARKER

1 WATT 2.2K 5% RESISTOR

RELAY BASE

120 VAC ISOLATION RELAY

24 VDC RELAY

12/24 VDC POWER SUPPLY

TWO 12 VOLT 50 AH BATTERIES

E1.5x1.5 DG6

C1.5DG6

08 01 73 3

30 04 36 2

30 04 26 5

55 31 72 3

55 31 92 7

55 30 93 1

1DM401

PANDUIT

SHEET METAL

MICRO SWITCH

PHOENIX CONTACT

PHOENIX CONTACT

ALLEN-BRADLEY

TOYO BATTERY CO.

1A

1B

1C

1D

1H

1G

1E

2E

2D

2C

2B

2A

2R

2Q

2P

2N

2M

2L

2K

2H

2G

4A

4B

PANDUIT

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT

BURNDY

ALLEN-BRADLEY

ALLEN-BRADLEY

PHILIPS (NEWARK)

PHOENIX CONTACT

PHOENIX CONTACT

PHOENIX CONTACT

KC22B1

CUSTOM

30 03 02 0

08 00 88 6

55 31 76 5

08 00 30 7

700-HN 121

700-HK36-A1

PRO1-2K2(08WX8181)

700-HK36-Z24

2J PHOENIX CONTACT

6GFM50B

TYPE SP SERVICE GRD POST CONNECTOR

2V PHOENIX CONTACT 55 31 03 7 8AMP CIRCUIT BREAKER-1 POLE

2W PHOENIX CONTACT 55 31 86 2 10AMP CIRCUIT BREAKER-1 POLE

2U 30 04 03 2 KNIFE DISCONNECTPHOENIX CONTACT

6A

6B

4J

4K

2Z

2AA

FURNISHED BY CONTRACTOR

FURNISHED BY CONTRACTOR

4 COND, #14 AWG SIS CONDUCTORS

6 COND, #14 AWG SIS CONDUCTORS

PHOENIX CONTACT

PHOENIX CONTACT

28 39 33 4

28 39 28 2

PT 2-PE/S-120 AC-ST MAINS-PLUG TRAB

PT-BE/FM MAINS-PLUG TRAB HEADER

PHOENIX CONTACT2X 16 AMP CIRCUIT BKR - 2 POLE W/AUX CONTACTS55 30 89 2

MANUFACTURER

PART # DESCRIPTION

MOTOROLA3A 18-72 VDC POWER SUPPLY

CPU ACE 3640

16DI

8AI 4-20 MA MODULE

OPTION V251

OPTION V446

OPTION V265

OPTION V318

OPTION V616

QTY(1)

QTY(1)

QTY(1)

QTY(1)

QTY(1)

MOTOROLA

MOTOROLA

MOTOROLA

MOTOROLA

16DO EE MODULE, 2AMP RELAYS

16DIOPTION V265

QTY(1)

MOTOROLA

2F PHOENIX CONTACT

PHOENIX CONTACT2S 28 17 14 9 PT 1X2-24VAC ST PROTECTIVE PLUG

PHOENIX CONTACT2AB 28 38 22 8 MCR PLUG TRAB PLUG (2 X 2)

PHOENIX CONTACT2AC 28 39 20 8 MCR PLUG TRAB BASE ELEMENT (2 X 2)

WEATHER HEAD5K METAL

AS SPECIFIED

FLEXIBLE ANTENNA CABLE IN RIGID CONDUIT

SMA MALE OR RIGHT ANGLE SMA MALE CONNECTOR5P

N MALE CONNECTOR 5L

5M BELDEN

901-9876-RFX OR 901-9880-RFX

82-5375-RFX

IS-50NX-C2

LMR-400UF

ANTENNA POLE

ANTENNA

LMR ANTENNA CABLE IN RIGID CONDUIT

TC-400NFC

TIMES MICROWAVE SYSTEMS

POLYPHASER (TESSCO)

4RF APRISA

ANTENNA POLE

5G

5F

5D

5B

5A

5H

SURGE ARRESTOR

5J

5C

N MALE CONNECTOR

N FEMALE CONNECTOR

TELECONNECT, GRAYBAR PN# GRA 031D1217-007)

CABLE KIT (ALSO AVAILABLE FROM ATLANTIC 5Q MOTOROLA FLN6458A

DIN RAIL MOUNTING KIT5R 4RF APRISA

AMPHENOL

AMPHENOL

TC-400NM

TIMES MICROWAVE SYSTEMS

FURNISHED W/ANTENNA

REF

S T

A T

IO

N C

O N

T R

O L C

E N

T E

R

-B

B C

W -T

S .d g n

SCC SYSTEM COMPONENTS SCHEDULE

DRAWING NO. T-17.

SCC SYSTEM COMPONETS SHOWN ON INTERIOR DIAGRAM ON 1.

3-POSITION SECTOR SWITCH (REMOTE - LOCAL - OFF)

5R SENES MODEL ASPSQ-N135-SSC-HD-22-ENAA

IFS

6C

D7100

FIBER OPTIC TRANSCEIVER

INDUSTRIAL ETHERNET SWITCH

UPS FOR CAMERA SWITCH AND TRANSCEIVERS

7A

7B

120V SURGE SUPPRESSOR

120V POWER DISTRIBUTTON CIRCUIT BREAKERS (AS REQUIRED)

RADIO

70" X 31.5" SS ENCLOSURE

PUSH BUTTON

2856032

A

A

/1

/2

R E

V

IS

E D T

O A

C C

O M

P A

N Y A

M M

E N

D M

E N

T N

O

PLUG TRAB BASE ELEMENT (1 X 2) UFBK

PLUG TRAB PLUG (1 X 2)

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

/1

/2

F

IL

E N

A M

E

D R

A W

IN

G D

A T

E pw:\\COE-SAJPWP02JAX.saj.ds.usace.army.mil:SAJPW\Documents\CERP\Biscayne Bay Costal Wetlands (BBCW) L-31E\510 - Contract 4 (P.S. S-709; Culverts S-706A&slash;706B&slash;706C&slash;708)\080 - Plans\14 Telecommunications\T-16 Am004

W E

P -2

-R -0

M M

M M

M M

M M

M Y

Y Y

Y

A N

S I

D

N /A

J A

C K

S O

N V

IL

L E D

IS

T R

IC

T

S

A N M

A R

C O B

L V

D

J A

C K

S O

N V

IL

L E F

L

C O

M P

R E

H E

N S

IV

E E

V E

R G

L A

D E

S R

E S

T O

R A

T

IO

N P

R O

G R

A M

B

IS

C A

Y N

E C

O A

S T

A L W

E T

L A

N D

S P

H A

S E I P

R O J E

C T

L -3

E F

L O

W -W

A Y P

U M

P S

T A

T

IO

N S -7

07_Telecommunications_BBCW_Am004.pdf
T-16 Am004

File details come from the government source that posted it. Updated .