W912EK22B0012 Amendment 0001 Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- W912EK22B0012
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
S I
D
S O
L
IC
IT
A
T
IO
N
M A
R S
E
IL
L E
S A
N D
S T
A R
V E
D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L
E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D
D A
M
S T
A R
V E
D R
O C
K L
O C
K A
N D
D A
M
IL
L
IN
O
IS
R
IV
E
R B
A S
IN
/0
/1
R O
C K
I S
L A
N D
IL
L
IN
O
IS
R
C K
I S
L A
N D
D
IS
T R
IC
T
J B
A R
T E
K
G
N E
R A
L N
O T
E S
E L
E C
T R
IC
A
L
E-001
T B
U L
L A
R D
N
V E
E N
A U
G
M
N D
S H
E E
T R
E
IS
S U
D
B
IW
P
R O
J
D T
E P
E N
MAR-MACH
W
E K
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
GENERAL ELECTRICAL WORK
EXISTING MITER GATE MOTOR CONTROLLERS TO NEW MITER GATE MACHINERY
PROVIDE NEW POWER AND CONTROL CONNECTORS AND CONDUCTORS FROM •
INDICATED HEREIN.
CONTROLS, LIGHTING, COMMUNICATION, AND DISTRIBUTION EQUIPMENT AS
PROVIDE ALL NEW CABLES (AND CONDUIT WHERE REQUIRED) FOR LOCK •
TESTING AND COMMISSIONING THE ELECTRICAL SYSTEMS•
LEAVES AFTER REPLACEMENT OF MITER GATE MACHINERY
ADJUST STRUT-ARM LIMIT SWITCH ASSEMBLIES ON ALL FOUR MITER GATE •
CLOSURE PERIOD INCLUDING BUT NOT LIMITED TO:
ALL REMAINING WORK MUST BE COMPLETED DURING THE NAVIGATION 2B.
CROSSOVER DUCTBANKS
SIGHT LAYOUT AND CONSTRUCTION OF NEW MANHOLES FOR NEW •
CLEAN OUT SILT IN EXISTING MANHOLES AND ABOVE GROUND DUCTBANKS•
INSTALLATION:
OF THE NAVIGATION CLOSURE PERIOD AND READY FOR CONTINUED
WORK THAT SHOULD BE SUBSTANTIALLY COMPLETE BEFORE THE BEGINNING 2A.
NAVIGATION CLOSURE WORK PERIOD(S):
WORK SEQUENCE IS RECOMMENDED DUE TO THE BRIEF DURATION OF THE
ELECTRICAL MEASUREMENTS AND PAYMENT LINE ITEMS. THE FOLLOWING
CONSTRUCTION SEQUENCE: SEE ALSO SPECIFICATION SECTION 01 20 00 FOR 2.
ATTEND AS COORDINATED. SEE OTHER COMMISSIONING REQUIREMENTS.
COMMISSIONING PROGRESS AND STATUS. GOVERNMENT PERSONNEL WILL
OF COMMISSIONING. THE GOVERNMENT SHALL BE KEPT INFORMED OF THE
START THE COMMISSIONING NOT LESS THAN 7 DAY PRIOR TO FORMAL START
OTHERWISE APPROVED, THE CONTRACTOR SHALL PROVIDE A REQUEST TO
PREPARE AND SUBMIT A COMMISSIONING PLAN FOR APPROVAL. UNLESS
VERIFICATION WITH THE FUNCTION(S) IT SERVES. THE CONTRATOR SHALL
CONTROL CIRCUIT, INTERLOCK BYPASS CONTROL CIRCUITS, AND PILOT LIGHT
CONTROL OPERATIONS, FILLING/EMPTYING VALVE AND MITER GATE INTERLOCK
UPSTREAM AND DOWNSTREAM MITER GATES AND FILLING/EMPTYING VALVE
LOCK OPERATES CORRECTLY, TESTS SHALL INCLUDE BUT IS NOT LIMITED TO
MAINTAIN A FULLY FUNCTIONAL SYSTEM. TO VERIFY THAT THE NAVIGATION
SHALL REPAIR NAVIGATION LOCK ELECTRICAL FUNCTIONS AS REQUIRED TO
THE CONTRACTOR SHALL CONDUCT A PERFORMANCE ASSESSMENT TEST AND
TEST TIME SHALL START AGAIN AFTER PROBLEMS ARE CORRECTED.
DOWNSTREAM BOUND CYCLES AND IF THERE ARE ANY FAILURES THEN THE
THROUGH NOT LESS THAN TWO UPSTREAM BOUND CYCLES AND TWO
THE CONTRACTOR SHALL TEST THE NAVIGATION LOCK BY RUNNING IT
CORRECT BUBBLER AIR-VALVE OPERATION FOR UPPER AND LOWER LANDWALL.
OPERATIONS FROM EACH CONTROL STAND CONSOLE, AND SHALL VERIFY
AND FUNCTION OF EACH MITER GATE INTERLOCK, ALL LIGHTING CONTROL
PROPER-OPERATION OF ALL LOCK MACHINERY INCLUDING PROPER OPERATION
AND COMMISSION ALL LOCK CONTROLS TO CONFIRM FULL-FUNCTION AND
SAME MANNER AS IT DID PRIOR TO CONSTRUCTION OF THIS PROJECT. TEST
OPERATION. THE LOCK MACHINERY SHALL OPERATE AND FUNCTION IN THE
SYSTEMS FUNCTIONS SHALL ALL BE RESTORED TO PRE-CONSTRUCTION
THE NAVIGATION LOCK POWER, CONTROL, COMMUNICATION, AND LIGHTING 1.
COMMISSIONING REQUIREMENTS: J.
FUNCTIONAL LOCK OPERATING SYSTEM.
COORDINATE WITH COR TO CONFIRM AND DEMONSTRATE A COMPLETELY
LIGHTING ASSOCIATED WITH CONTROL CONSOLES AND MITER LIMIT-SWITCHES.
TEST, AND COMMISSION ALL LOCK POWER, CONTROLS, INTERLOCKS AND B.
AFTER REPLACEMENT OF MITER GATE MACHINERY.
SWITCHES FOR EACH OF FOUR MITER GATE LEAVES (16 TOTAL PER LOCK)),
ADJUST EXISTING MITER GATE STRUT-ARM LIMIT SWITCHES ((4) LIMIT A.
ELECTRICAL WORK WILL INCLUDE BUT IS NOT LIMITED TO: 2.
BANK LOCATOR MARKINGS.
LABELED TO INDICATE LOCATION OF PHOTO TAKEN, AND PHOTOS OF DUCT
PRE-CONSTRUCTION CONDITION PHOTOS OF EQUIPMENT AND CONTROLS,
VALVE OPERATION "OPEN" VS "CLOSE" FUNCTIONS. DOCUMENTS WILL INCLUDE
STRUT-ARM LIMIT SWITCH SETTINGS, MITER GATE AND FILLING/EMPTYING
SETTINGS INCLUDING ITEMS SUCH AS ROTATING CAM LIMIT SWITCHES, THE
PROVIDE SUBMITTAL DOCUMENT OF PRE-CONSTRUCTION CONTROLS
AS A PART OF THE COMMISSIONING PLAN SUBMITTAL, CONTRACTOR MUST 1.
MACHINERY AND CONTROL CONSOLE TO RAISED JUNCTION BOXES.
CONDUCTORS THAT RUN BETWEEN CORNERS MUST BE CONTINUOUS FROM
RAISED JUNCTION BOXES AT A CORNER OF THE LOCK. INTERLOCK
CONTROL CONSOLE OR OTHER MACHINERY AS REQUIRED. BYPASSING THE
NEW CONDUCTORS MUST BE CONTINUOUS FROM NEW MACHINERY TO 28.
AND DOCUMENT CHANGES THAT MAY EFFECT INSTALLATION OR OPERATION.
CONDITIONS. THE CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS
THE EXISTING ELECTRICAL DRAWINGS INDICATE GENERAL ELECTRICAL 27.
DRAWINGS. SEE SPECIFICATIONS FOR FURTHER REQUIREMENTS.
VALVE MACHINERY ASSOCIATED WITH THIS CONTRACT ON RED LINE AS BUILT
PLAN SKETCHES OF ALL MITER GATE MACHINERY AND FILL AND EMPTYING
AS BUILT DRAWINGS: CONTRACTOR MUST INCLUDE DETAILED LOCATIONS AND 26.
OTHERWISE .
ALL CONDUCTORS MUST BE INSTALLED IN RACEWAY, EXCEPT WHERE NOTED 25.
KEEP 120 VOLT WIRING AND 480 VOLT WIRING IN SEPARATE CONDUITS. 24.
CURRENT CARRYING CONDUCTORS IN ONE CONDUIT.
EXCEPT FOR NIPPLES SHORTER THAN 24 INCHES, DO NOT RUN MORE THAN 9 23.
CONDUIT ROUTING.
THE GOVERNMENT HAS FINAL APPROVAL ON ALL EQUIPMENT LOCATIONS AND 22.
ANCHORS ARE NOT PERMITTED.
WEDGE TYPE CONCRETE ANCHORS AND POWDER ACTUATED CONCRETE 21.
FASTEN CONDUIT TO ELECTRICAL JUNCTION BOXES.
INSULATED THROAT GROUNDING TYPE CONDUIT HUBS SHALL BE USED TO 20.
ELECTRICAL ENCLOSURES, BOXES, AND HAND HOLES.
PROVIDE INSULATING BUSHINGS AT TERMINATION OF CONDUITS AT ALL 19.
THIS REQUIREMENT. USE NON-FERROUS SCREWS TO ATTACH NAMEPLATES.
SIZE (IF APPLICABLE). LABELING SWITCH AS S-A, S-B, ETC., DOES NOT SATISFY
NAME AND FUNCTION INCLUDING OPERATING VOLTAGE, AND MAXIMUM FUSE
HIGH LETTER TO IDENTIFY ALL MAJOR PIECES OF ELECTRICAL EQUIPMENT BY
AND NEW EQUIPMENT, MUST BE UV RATED ENGRAVED PLASTIC WITH 3/16 INCH
NAMEPLATES FOR NEW PANEL BOARDS, JUNCTION BOXES, TERMINAL BLOCKS, 18.
ACCORDANCE WITH NFPA 70 FOR ALL CABLES INCLUDED IN THIS PROJECT.
CABLE SUPPORTS IN GALLERIES OR CONCRETE CABLE TROUGHS SPACED IN
OTHER CONDUIT, EQUIPMENT, MACHINERY, OR PIPING. PROVIDE NONMETALLIC
SUPPORTS FOR EXPOSED CONDUITS. CONDUIT MUST NOT BE SUPPORTED BY
WITHIN 3 FEET OF EACH BOX AND FITTING. USE STRAP TYPE CONDUIT
PROVIDE SUPPORT AT EACH BOX. PROVIDE AN ADDITIONAL CONDUIT SUPPORT 17.
MINIMUM CONDUIT SIZE SHALL BE 1 INCH RIGID GALVANIZED STEEL CONDUIT.
FOR #8 AWG AND LARGER. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG, AND
XHHW INSULATION. USE SOLID FOR #10 AWG AND SMALLER, AND STRANDED
NEW CONDUCTORS MUST BE COPPER, 600 VOLT, 90 DEGREE CELSIUS, TYPE 16.
TRANSITION TO PVC COATED RGS BEFORE IT EXITS THE CONCRETE.
CONCRETE ENCASED DUCTS SHALL BE PVC SCHEDULE 40, AND SHALL
PROVIDE A COMPLETE AND CONTINUOUS RACEWAY SYSTEM. UNO, ALL NEW
UL LISTED PVC COATED RIGID GALVANIZED STEEL (RGS) TYPE CONDUIT TO
UNLESS OTHERWISE NOTED, ALL CONDUITS AND CONDUIT FITTINGS MUST BE 15.
WITH RELEVANT AMERICAN INDUSTRY STANDARDS (NEMA, ANSI, ETC.).
EQUIPMENT, TERMINALS, TERMINATORS, AND WIRE LABELS MUST COMPLY
WIRE, CABLES, ENCLOSURES, COVERS, RECEPTACLES, SWITCHES, GROUNDING
ALL NEW INSTALLED EQUIPMENT INCLUDING, BUT NOT LIMITED TO: CONDUIT, 14.
ALL NEW ELECTRICAL EQUIPMENT MUST BE LISTED BY A NRTL. 13.
MAKING THE ACTUAL ELECTRICAL INSTALLATION.
THE CONTRACTOR MUST COORDINATE ALL EQUIPMENT LOCATIONS PRIOR TO 12.
INSULATED GREEN GROUND WIRE.
ALL BRANCH AND FEEDER CIRCUITS MUST BE PROVIDED WITH A SEPARATE 11.
STRUCTURAL DRAWINGS.
CONCRETE WORK TO FACILITATE STRUCTURAL CONSTRUCTION. SEE
THE ELECTRICAL WORK MUST BE COORDINATED WITH THE STRUCTURAL 10.
CODE.
ACCORDANCE WITH THE LATEST EDITION OF NFPA 70, NATIONAL ELECTRICAL
ALL FEATURES OF ELECTRICAL WORK AND INSTALLATION MUST BE IN 9.
SUBMERGED.
LOCK WALL, AND CARE MUST BE TAKEN TO PROTECT CABLE ENDS FROM BEING
OCCASIONS WHEN THE RIVER MAY FLOOD AND WATER MAY OVERTOP THE
THE CONTRACTOR MUST BE AWARE AND CONSIDER THAT THERE ARE 8.
PERSONNEL.
NECESSARY UPPER LOCK WALL AREAS BY THE LOCK AND DAM OPERATING
COORDINATED WITH THE CONTRACTING OFFICER TO ALLOW ACCESS TO
STAGING OF EQUIPMENT REMOVAL, RELOCATION, AND INSTALLATION MUST BE 7.
IN ITS ENTIRETY FROM SOURCE TO LOAD AT THE CONTRACTOR'S EXPENSE.
ANY PERMANENT CABLES DAMAGED BY THE CONTRACTOR MUST BE REPLACED 6.
THE CONTRACTOR'S EXPENSE.
CONTRACTOR (OTHER THAN AS INDICATED IN PLANS) MUST BE REPAIRED AT
ANY DAMAGE TO DUCT BANK, GALLERIES OR EMBEDDED CONDUITS BY THE 5.
1-1 DATED 30 NOVEMBER, 2014, SECTION 12.
ACCORDANCE WITH THE SAFETY AND HEALTH REQUIREMENTS MANUAL EM 385-
CONTRACTOR MUST ADHERE TO PROPER LOCKOUT/TAG OUT PROCEDURES IN 4.
1-1 DATED 30 NOVEMBER, 2014, SECTION 11, SUBSECTION J.
ACCORDANCE WITH THE SAFETY AND HEALTH REQUIREMENTS MANUAL EM 385-
CONTRACTOR MUST PROVIDE PROTECTION FROM OPEN MANHOLES IN 3.
THIS PROJECT.
AND OTHER PERMENANT REFERENCE POINTS TO ADD AS BUILT DRAWINGS FOR
GOVERNMENT. PROVIDE SKETCHES WITH MEASUREMENTS FROM LOCKWALL
MARKER PAINT, AND PROVIDE PHOTO AND VIDEO FILES OF PAINT LOCATORS TO
PROVIDE LOCATE SERVICES IN WORK AREAS, MARK ELECTRICAL DUCTS USING
PRIOR TO ANY CONCRETE EXCAVATION WORK, THE CONTRACTOR MUST 2.
CONTRACTING OFFICER PRIOR TO ANY ELECTRICAL POWER OUTAGES.
CONTRACTOR MUST COORDINATE WITH AND RECEIVE APPROVAL FROM THE 1.
THAT MUST BE REMOVED.
WORK REQUIRED, AND DO NOT INDICATE EVERY BOX, CONDUIT OR WIRE
ELECTRICAL DEMOLITION NOTES ARE INTENDED TO INDICATE THE SCOPE OF 35.
INTERLOCK SAFETYS DURING NORMAL NAVIGATION OPERATIONS.
COORDINATED AND PROVIDED TO MAINTAIN OR BYPASS CONTROLS
CLOSURE, CARE SHALL BE TAKEN TO ASSURE NECESSARY JUMPERING IS
TEMPORARY CONTROLS CABLING IS REQUIRED PRIOR TO NAVIGATION
COORDINATED AND APPROVED BY THE CONTRACTING OFFICER. IF
TO NAVIGATION CLOSURE. SHORT OUTAGES SHALL BE PERMITTED AS
FILLING/EMPTYING VALVE AND MITER GATE OPERATION AT ALL TIMES PRIOR
THE CONTRACTOR SHALL MAINTAIN CONTINUITY OF CONTROL CIRCUITS FOR 34.
INGRESS/EGRESS HATCH IN ACCORDANCE WITH EM 385-1-1.
THE CONTRACTOR SHALL PROVIDE LADDER ACCESS INTO THE GALLERY
GALLERY. THE EXISTING PERMANENT LADDER IS NOT SUITABLE FOR USE.
TO PERFORM PUMPING TO ALLOW AND MAINTAIN WORKER ACCESS INTO THE
NEEDS REQUIRE TO PUMP WATER OUT OF THE GALLERY AND AS REQUIRED
THE GOVERNMENT. THE CONTRACTOR SHALL PROPERLY COORDINATE AS
GALLERY PERIODICALLY CONTAINS WATER WHICH WILL BE PUMPED OUT BY
SHALL APPLY AND BE ADHERED TO IN ACCORDANCE WITH EM 385-1-1. THE
THE GALLERY IS A CONFINED SPACE FOR WHICH ALL SAFETY REQUIRMENTS 33.
CONDITIONS. REFERENCE DRAWINGS ARE NOT PRINTED TO SCALE.
NOT "AS BUILT" SO THEY DO NOT NECESSARILY REPRESENT ACTUAL FIELD
SHOWN ON THE REFERENCE DRAWINGS. THE REFERENCE DRAWINGS ARE
THE CONTRACTOR'S BENEFIT. NO REQUIRED WORK ON THIS CONTRACT IS
REFERENCE DRAWINGS ARE DRAWINGS OF RECORD INCLUDED SOLELY FOR 32.
ALL WIRING SHALL BE FIELD VERIFIED.
SITES IS VERY SIMILAR, AND IS ASSUMED TO BE FUNCTIONALLY IDENTICAL.
STRUT ARM LIMIT SWITCH WIRING. THIS WIRING AND DIMENSIONS FOR BOTH
ARE FROM MARSEILLES LOCK. THESE WERE INCLUDED IN THIS SET TO SHOW
REFERENCE DRAWINGS (Vol.I, STARVED ROCK): NOTE THAT SEVERAL SHEETS 31.
CABLES TO BE REPLACED OR INSTALLED.
TO: SIZE, QUANTITY, TYPE, AND TERMINAL AND RACEWAY ROUTING OF ALL
RESPONSIBLE FOR FIELD CONFIRMING ITEMS INCLUDING, BUT NOT LIMITED
CONTROL DIAGRAMS, AND CABLE NAMES AND LOCATIONS. CONTRACTOR IS
SEE REFERENCE DRAWINGS FOR APPROXIMATE EXISTING EQUIPMENT, 30.
INSTALLED ACROSS CONCRETE MONOLITH OR EXPANSION JOINTS.
JOINTS. CONTRACTOR MUST IDENTIFY ALL NEW CONDUITS THAT WILL BE
ARE EMBEDDED, USE EXPANSION AND DEFLECTION FITTINGS AT MONOLITH
FITTING MUST BE PROVIDED WITH GROUNDING JUMPER. WHERE CONDUITS
CONDUITS CROSS CONCRETE EXPANSION JOINTS. TYPE EX CONDUIT
CONDUIT FITTINGS MUST BE PROVIDED IN LOCATIONS WHERE NEW
WHERE CONDUITS ARE EXPOSED, RIGID TYPE EX EXPANSION/CONTRACTION 29.
GENERAL ELECTRICAL NOTES
CONTRACTING OFFICER.
FROM THE SITE WEEKLY OR MORE OFTEN IF SO DIRECTED BY THE
THE CONTRACTOR SHALL PROPERLY DISPOSE OF DEMOLITION ITEMS 2.
CABLING AND CONNECTIONS ARE TO BE PROVIDED.
MITER GATE MACHINERY FOR THE LOCK. NEW POWER AND CONTROL
THE SCOPE OF WORK INCLUDES DEMOLITION AND REPLACEMENT OF 1.
CONTROLLER CABINET.
INSTALL NEW AC BRAKE CONTROLLER IN EXISTING MITER GATE MOTOR 3.
AND HOUSINGS.
EXISTING STRUT-ARM LIMIT SWITCHES WITH NEW FABRICATED MOUNTING 2.
THE NEW FILLING AND EMPTYING VALVE MACHINERY.
CONDUCTORS FROM THE FILLING AND EMPTYING VALVE RECEPTACLE TO
RECEPTACLES FOR FILLING AND EMPTYING VALVES. PROVIDE NEW
PROVIDE NEW CONNECTORS TO MATE WITH EXISTING ELEVATED 1.
DEMOLITION NOTES
EQUIPMENT TO BE INSTALLED:
THE FOLLOWING SUMMARIZES NEW
(4) MITER GATE DC BRAKES AND BRAKE CONTROLLERS.2.
CONDUCTORS.
ALL FOUR (4) EXISTING MITER GATE MACHINERY POWER AND CONTROL 1.
DEMOLITION OR REMOVAL
THE FOLLOWING IS SCHEDULED FOR
S I
D
S O
L
IC
IT
A
T
IO
N
M A
R S
E
IL
L E
S A
N D
S T
A R
V E
D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L
E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D
D A
M
S T
A R
V E
D R
O C
K L
O C
K A
N D
D A
M
IL
L
IN
O
IS
R
IV
E
R B
A S
IN
/0
/1
R O
C K
I S
L A
N D
IL
L
IN
C K
I S
L A
N D
D
IS
T R
B
A R
T E
K
U P
S T
R E
A M
L A
N D
W A
L L
M
IT
E R
G A
T E
E L
E C
T R
IC
A
L
P L
A N
E-102
T B
U L
L A
R D
N
V E
E N
A U
G
N D
K E
Y N
O T
E S
U P
D A
T
IW
P
R O
J
D T
E P
E N
MAR-MACH
W
E K
B
SWITCH ASSEMBLY
STRUT-ARM LIMIT
ALLOW FULL GATE MOTION.
CONNECTION TO STRUT-ARM LIMIT SWITCH TO
4 FT SECTION OF RETRACTING SOW CORD FOR
CONTROLS CONSOLE
LOCATION OF
STAND
ELEVATED CONTROL
EARTH
ENCASED DUCT BANK IN
EXISTING CONCRETE-
SAWCUT IN LOCKWALL
ENCASED DUCT BANK,
EXISTING CONCRETE-
WIRING
LS & HEATER
STRUT-ARM
STEEL BRADED RACEWAY
EXTRA FLEX STAINLESS-
CONTROL AND EXISTING EQUIPMENT.
ELEVATED JUNCTION BOXES BETWEEN THE
TROUGH
GROUND CONCRETE CABLE
EXISTING (PARTIALLY) ABOVE
CONTROLLER
MITER GATE MOTOR
SWITCH
RECESSED PROXIMITY
MITER GATE FULLY
TO OPPOSING GATE
END OF GATE MITER
MITER PROXIMITY SWITCH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SEE REFERENCE DRAWINGS FOR EXISTING CABLES AND CONNECTIONS. 2.
SEE NOTES ON SHEET E-001.1.
GENERAL SHEET NOTES
N
SHEET KEYNOTES
REQUIRED.
SENSOR TO RELAY IN CONTROL CONSOLE THRU CONDUIT AND GALLERY AS
CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL CABLE FROM
PROXIMITY LIMIT SWITCH MOUNTING AND E-700 SERIES FOR ELEMENTARY
"PROOF OF MITER" PROXIMITY LIMIT SWITCH, SEE E-502 THRU E-505 FOR
TO NEW MITER GATE "PROOF OF MITER" PROXIMITY LIMIT SWITCH. PROVIDE
PROVIDE NEW 1" RGS CONDUIT FROM STRUT ARM ASSEMBLY BUFFER BOX 6.
CONDUIT AND GALLERY AS REQUIRED.
CABLES FROM SENSOR TO RELAY IN CONTROL CONSOLE THRU NEW
ELEMENTARY CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL
THRU E-505 FOR PROMITY SWITCH MOUNTING. SEE E-700 SERIES FOR
PROVIDE MITER GATE RECESSED PROXIMITY SENSOR AND RELAY. SEE E-502 5.
DEVICES, CONDUIT AND CONDUCTORS REQUIRED.
AND E-700 SERIES FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL
EXISTING CONTROL CONSOLE TO BE MODIFIED, SEE SHEETS E-512, E-513, 4.
LIMIT SWITCH TO ALLOW FULL GATE MOTION.
4 FT SECTION OF RETRACTING SOW CORD FOR CONNECTION TO STRUT-ARM 3.
CONSOLE. ROUTE CONDUCTORS THRU CONDUIT AND GALLERY.
CABLES FROM EXISTING MITER GATE MOTOR CONTROLLER TO CONTROL
AND CONDUCTORS REQUIRED. PROVIDE TWO 8-CONDUCTOR CONTROL
FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL DEVICES, CONDUIT
OPEN TORQUE LIMIT, AND CLOSE TORQUE LIMIT, SEE SHEETS E-700 SERIES
PROVIDE PRESS TO TEST INDICATORS FOR GATE RECESS, GATES MITERED,
CONTRACTOR INSTALLED EQUIPMENT.
AND CLOSED TORQUE SWITCHES ARE GOVERMENT FURNISHED
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. OPEN TORQUE
BACK TO RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. ALL DEVICES,
PROVIDE OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHES CABLING
INTERLOCK RECEPTACLES FOR LOW SPEED AND HIGH SPEED.
PROVIDE NEW CORD AND CONNECTOR THAT MATES WITH EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED.
CONDUCTOR CABLING TO EXISTING INTERLOCK RECEPTACLES. ALL
PROVIDE NEW MOTOR HIGH SPEED AND LOW SPEED WINDING FLEXIBLE
MOTOR CONTROLLER CABINET TO MOTOR WINDING HEATER.
BE PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL
CONNECT NEW MOTOR WINDING HEATER TO EXISTING CIRCUIT. ALL
MOTOR CONTROLLER CABINET TO AC BRAKE HEATER.
PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL BE
CONNECT NEW AC BRAKE HEATER TO EXISTING CIRCUIT. ALL DEVICES,
CONNECTIONS FOR ROTARY CAM LIMIT SWITCH HEATER CIRCUIT.
EQUIPMENT. PROVIDE NEW CONDUIT, CONDUTOR, DEVICES AND
SWITCHES ARE GOVERMENT FURNISHED CONTRACTOR INSTALLED
REQUIRED FOR MODIFICATION SHALL BE PROVIDED. ROTARY CAM LIMIT
ROTARY CAM LIMIT SWITCHES. ALL DEVICES, CABLES AND CONDUCTORS
THE MOTOR CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW MOTOR
CONDUCTORS AS NECESSARY.
CONNECTED TO EXISTING CABLING. PROVIDE NEW CONDUIT, FITTINGS, AND
PROVIDE NEW AC BRAKE HEATER. AC BRAKE HEATER CIRUIT SHALL BE
EQUIPMENT.
NEW AC BRAKE IS GOVERMENT FURNISHED CONTRACTOR INSTALLED
FOR INTEGRATING NEW AC BRAKE INTO EXISTING LOCK CONTROL SYSTEM.
BRAKE. PROVIDE MODIFCATIONS, CONDUIT, CONDUCTORS, ETC REQUIRED
THE MITER GATE CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW AC
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. PROVIDE OPERATIONS
DISCONNECT OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHS BACK TO
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE AND PROPERLY DISPOSE OF OFF SITE. PROVIDE OPERATIONS
DISCONNECT HIGH SPEED AND LOW SPEED WINDING CONNECTION BACK TO
REFUSAL CONTRACTOR SHALL PROPERLY DISPOSE OF OFF SITE.
DISCONNECTED AND OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH
ROTARY CAM LIMITING LIMIT SWITCHES ARE TO BE RECORDED AND
SHALL PROPERLY DISPOSE OF OFF SITE.
OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR
DC BRAKE AND BRAKE CONTROLLER ARE TO BE DISCONNECTED AND
EXISTING MITER GATE MOTOR CONTROLLER TO REMAIN. 2.
LEVER-ARM ACTUATION TO MATCH EXISTING OPERATION.
WITH NEW LIMIT SWITCH BOLT PATTERNS AS REQUIRED TO MAKE PROPER
EXISTING OPERATION. FABRICATE NEW STAINLESS STEEL MOUNTING PLATE
EXISTING STRUT ARM LIMIT SWITCHES AND ADJUST SETTINGS TO MATCH
SWITCHES DURING INSTALLATION OF NEW STRUT ARM. RECONNECT
POSITIVE-BREAK CONTACTS. DISCONNECT AND PROTECT STRUT-ARM LIMIT
LIMIT SWITCH, ADJUSTABLE LEVER, NEMA 4, AND IP67; DPDT, SNAP ACTION,
WIRING). THE LIMIT SWITCHES ARE: HONEYWELL SZL-VL-S SIDE ROTARY
PER LOCK)). (SEE REFERENCE SHEETS FOR DIMENSIONS, MOUNTING, AND
EACH OF FOUR MITER GATE LEAVES (16 LEVER-ARM LIMIT SWITCHES TOTAL
EXISTING MITER-GATE STRUT-ARM LIMIT SWITCHES ((4) LIMIT SWITCHES FOR 1.
VALVE MACHINERYVMR
GATE MACHINERYGMR
HYDRAULIC VALVEHV
CONTROL STATIONCS
LOWER LEFTLL
UPPER LEFTUL
LOWER RIGHTLR
UPPER RIGHTUR
ULCS
ULGMR
ULHV
A1
PLAN - UPSTREAM LANDWALL
SCALE: 1/8"=1'-0"
ABBREVIATIONS
0 8'4' 16'
E-502
G1
E-503
A1
S I
D
S O
L
IC
IT
A
T
IO
N
M A
R S
E
IL
L E
S A
N D
S T
A R
V E
D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L
E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D
D A
M
S T
A R
V E
D R
O C
K L
O C
K A
N D
D A
M
IL
L
IN
O
IS
R
IV
E
R B
A S
IN
/0
/1
R O
C K
I S
L A
N D
IL
L
IN
C K
I S
L A
N D
D
IS
T R
B
A R
T E
K
U P
S T
R E
A M
R
IV
E R
W A
L L
M
IT
E R
G A
T E
E L
E C
T R
IC
A
L
P L
A N
E-103
T B
U L
L A
R D
N
V E
E N
A U
G
N D
S H
E E
T K
E Y
N O
T E
S U
P D
A T
IW
P
R O
J
D T
E P
E N
MAR-MACH
W
E K
B
WIRING
SWITCHES AND
STRUT-ARM LIMIT
MITER GATE
ALLOW FULL GATE MOTION.
CONNECTION TO STRUT-ARM LIMIT SWITCH TO
4 FT SECTION OF RETRACTING SOW CORD FOR
CONSOLE
CONTROLS
LOCATION OF
STAND
CONTROL
ELEVATED
BANK
ENCASED DUCT
CONCRETE-
EXISTING
LOCATED IN QUOIN AREA
CONDUIT, 4' MINIMUM SECTION
STAINLESS STEEL EXTRA FLEX-
CONCRETE CABLE TROUGH
EXISTING ABOVE GROUND
CONTROLLER
MOTOR
MITER GATE
EQUIPMENT.
THE CONTROL AND EXISTING
ELEVATED JUNCTION BOXES BETWEEN
PROXIMITY SWITCH
MITER GATE FULLY RECESSED
TO OPPOSING GATE
END OF GATE MITER
MITER PROXIMITY SWITCH
(PROTECT DURING CONSTRUCTION)
POLE MOUNTED LIGHTING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SEE REFERENCE DRAWINGS FOR EXISTING CABLES AND CONNECTIONS. 2.
SEE NOTES ON SHEET E-001.1.
GENERAL SHEET NOTES
N
ON LANDWALL GATE.
ELEMENTARY CONTROL DIAGRAMS. CONDUIT AND CONDUCTORS LOCATED
THRU E-505 FOR PROXIMITY LIMIT SWITCH MOUNTING AND E-700 SERIES FOR
PROVIDE "PROOF OF MITER" PROXIMITY LIMIT SWITCH ASSEMBLY, SEE E-502 6.
CONDUIT AND GALLERY AS REQUIRED.
CABLE FROM SENSOR TO RELAY IN CONTROL CONSOLE THRU EXISTING
ELEMENTARY CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL
THRU E-505 FOR PROMITY SWITCH MOUNTING. SEE E-700 SERIES FOR
PROVIDE MITER GATE RECESSED PROXIMITY SENSOR AND RELAY. SEE E-502 5.
DEVICES, CONDUIT AND CONDUCTORS REQUIRED.
AND E-700 SERIES FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL
EXISTING CONTROL CONSOLE TO BE MODIFIED, SEE SHEETS E-512, E-513, 4.
LIMIT SWITCH TO ALLOW FULL GATE MOTION.
4 FT SECTION OF RETRACTING SOW CORD FOR CONNECTION TO STRUT-ARM 3.
CONSOLE. ROUTE CONDUCTORS THRU CONDUIT AND GALLERY.
CABLES FROM EXISTING MITER GATE MOTOR CONTROLLER TO CONTROL
AND CONDUCTORS REQUIRED. PROVIDE TWO 8-CONDUCTOR CONTROL
FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL DEVICES, CONDUIT
OPEN TORQUE LIMIT, AND CLOSE TORQUE LIMIT, SEE SHEETS E-700 SERIES
PROVIDE PRESS TO TEST INDICATORS FOR GATE RECESS, GATES MITERED,
CONTRACTOR INSTALLED EQUIPMENT.
AND CLOSED TORQUE SWITCHES ARE GOVERMENT FURNISHED
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. OPEN TORQUE
BACK TO RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. ALL DEVICES,
PROVIDE OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHES CABLING
RECEPTACLES FOR LOW SPEED AND HIGH SPEED.
CORD AND CONNECTOR THAT MATES WITH EXISTING INTERLOCK
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. PROVIDE NEW
CONDUCTOR CABLING TO EXISTING INTERLOCK RECEPTACLES. ALL DEVICES,
PROVIDE NEW MOTOR HIGH SPEED AND LOW SPEED WINDING FLEXIBLE
MOTOR CONTROLLER CABINET TO MOTOR WINDING HEATER.
BE PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL
CONNECT NEW MOTOR WINDING HEATER TO EXISTING CIRCUIT. ALL
MOTOR CONTROLLER CABINET TO AC BRAKE HEATER.
PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL BE
CONNECT NEW AC BRAKE HEATER TO EXISTING CIRCUIT. ALL DEVICES,
FOR ROTARY CAM LIMIT SWITCH HEATER CIRCUIT.
PROVIDE NEW CONDUIT, CONDUTOR, DEVICES AND CONNECTIONS EQUIPMENT.
SWITCHES ARE GOVERMENT FURNISHED CONTRACTOR INSTALLED
REQUIRED FOR MODIFICATION SHALL BE PROVIDED. ROTARY CAM LIMIT
ROTARY CAM LIMIT SWITCHES. ALL DEVICES, CABLES AND CONDUCTORS
THE MOTOR CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW MOTOR
CONDUCTORS AS NECESSARY.
CONNECTED TO EXISTING CABLING. PROVIDE NEW CONDUIT, FITTINGS, AND
PROVIDE NEW AC BRAKE HEATER. AC BRAKE HEATER CIRUIT SHALL BE
EQUIPMENT.
NEW AC BRAKE IS GOVERMENT FURNISHED CONTRACTOR INSTALLED
FOR INTEGRATING NEW AC BRAKE INTO EXISTING LOCK CONTROL SYSTEM.
BRAKE. PROVIDE MODIFCATIONS, CONDUIT, CONDUCTORS, ETC REQUIRED
THE MITER GATE CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW AC
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. PROVIDE OPERATIONS
DISCONNECT OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHS BACK TO
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE AND PROPERLY DISPOSE OF OFF SITE. PROVIDE OPERATIONS
DISCONNECT HIGH SPEED AND LOW SPEED WINDING CONNECTION BACK TO
REFUSAL CONTRACTOR SHALL PROPERLY DISPOSE OF OFF SITE.
DISCONNECTED AND OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH
ROTARY CAM LIMITING LIMIT SWITCHES ARE TO BE RECORDED AND
SHALL PROPERLY DISPOSE OF OFF SITE.
OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR
DC BRAKE AND BRAKE CONTROLLER ARE TO BE DISCONNECTED AND
EXISTING MITER GATE MOTOR CONTROLLER TO REMAIN. 2.
LEVER-ARM ACTUATION TO MATCH EXISTING OPERATION.
WITH NEW LIMIT SWITCH BOLT PATTERNS AS REQUIRED TO MAKE PROPER
EXISTING OPERATION. FABRICATE NEW STAINLESS STEEL MOUNTING PLATE
EXISTING STRUT ARM LIMIT SWITCHES AND ADJUST SETTINGS TO MATCH
SWITCHES DURING INSTALLATION OF NEW STRUT ARM. RECONNECT
POSITIVE-BREAK CONTACTS. DISCONNECT AND PROTECT STRUT-ARM LIMIT
LIMIT SWITCH, ADJUSTABLE LEVER, NEMA 4, AND IP67; DPDT, SNAP ACTION,
WIRING). THE LIMIT SWITCHES ARE: HONEYWELL SZL-VL-S SIDE ROTARY
PER LOCK)). (SEE REFERENCE SHEETS FOR DIMENSIONS, MOUNTING, AND
EACH OF FOUR MITER GATE LEAVES (16 LEVER-ARM LIMIT SWITCHES TOTAL
EXISTING MITER-GATE STRUT-ARM LIMIT SWITCHES ((4) LIMIT SWITCHES FOR 1.
SHEET KEYNOTES
VALVE MACHINERYVMR
GATE MACHINERYGMR
HYDRAULIC VALVEHV
CONTROL STATIONCS
LOWER LEFTLL
UPPER LEFTUL
LOWER RIGHTLR
UPPER RIGHTUR
URGMR
URCS
URHV
A1
PLAN - UPSTREAM RIVERWALL
SCALE: 1/8"=1'-0"
ABBREVIATIONS
0 8'4' 16'
E-504
G1
E-505
A1
S I
D
S O
L
IC
IT
A
T
IO
N
M A
R S
E
IL
L E
S A
N D
S T
A R
V E
D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L
E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D
D A
M
S T
A R
V E
D R
O C
K L
O C
K A
N D
D A
M
IL
L
IN
O
IS
R
IV
E
R B
A S
IN
/0
/1
R O
C K
I S
L A
N D
IL
L
IN
C K
I S
L A
N D
D
IS
T R
B
A R
T E
K
D O
W N
S T
R E
A M
L A
N D
W A
L L
M
IT
E R
G A
T E
E L
E C
T R
IC
A
L
P L
A N
E-104
T B
U L
L A
R D
N
V E
E N
A U
G
N D
S H
E E
T K
E Y
N O
T E
S R
E V
IS
IW
P
R O
J
D T
E P
E N
MAR-MACH
W
E K
B
SWITCH ASSEMBLY
STRUT-ARM LIMIT
ALLOW FULL GATE MOTION.
CONNECTION TO STRUT-ARM LIMIT SWITCH TO
4 FT SECTION OF RETRACTING SOW CORD FOR
CONSOLE
CONTROLS
LOCATION OF
EARTH
ENCASED DUCT BANK IN
EXISTING CONCRETE-
ENCASED DUCT BANK
EXISTING CONCRETE-
WIRING
LS & HEATER
STRUT-ARM
4' SECTION LOCATED IN MITER GATE QUOIN AREA
EXTRA FLEXIBLE STAINLESS STEEL BRADED CONDUIT,
CONTROL AND EXISTING EQUIPMENT.
ELEVATED JUNCTION BOXES BETWEEN THE
CONCRETE CABLE TROUGH
EXISTING ABOVE GROUND
CONTROLLER
MITER GATE MOTOR
STAND
CONTROL
ELEVATED
PROXIMITY SWITCH
MITER GATE RECESSED
TO OPPOSING GATE
END OF GATE MITER
MITER PROXIMITY SWITCH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SEE REFERENCE DRAWINGS FOR EXISTING CABLES AND CONNECTIONS. 2.
SEE NOTES ON SHEET E-001.1.
GENERAL SHEET NOTES
GALLERY AS REQUIRED.
SENSOR TO RELAY IN CONTROL CONSOLE THRU EXISTING CONDUIT AND
CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL CABLE FROM
PROXIMITY LIMIT SWITCH MOUNTING AND E-700 SERIES FOR ELEMENTARY
"PROOF OF MITER" PROXIMITY LIMIT SWITCH, SEE E-502 THRU E-505 FOR
TO NEW MITER GATE "PROOF OF MITER" PROXIMITY LIMIT SWITCH. PROVIDE
PROVIDE NEW 1" RGS CONDUIT FROM STRUT ARM ASSEMBLY BUFFER BOX 6.
GALLERY AS REQUIRED.
CABLE FROM SENSOR TO RELAY IN CONTROL CONSOLE THRU CONDUIT AND
ELEMENTARY CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL
THRU E-505 FOR PROMITY SWITCH MOUNTING. SEE E-700 SERIES FOR
PROVIDE MITER GATE RECESSED PROXIMITY SENSOR AND RELAY. SEE E-502 5.
DEVICES, CONDUIT AND CONDUCTORS REQUIRED.
AND E-700 SERIES FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL
EXISTING CONTROL CONSOLE TO BE MODIFIED, SEE SHEETS E-512, E-513, 4.
LIMIT SWITCH TO ALLOW FULL GATE MOTION.
4 FT SECTION OF RETRACTING SOW CORD FOR CONNECTION TO STRUT-ARM 3.
CONSOLE. ROUTE CONDUCTORS THRU CONDUIT AND GALLERY.
CABLES FROM EXISTING MITER GATE MOTOR CONTROLLER TO CONTROL
AND CONDUCTORS REQUIRED. PROVIDE TWO 8-CONDUCTOR CONTROL
FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL DEVICES, CONDUIT
OPEN TORQUE LIMIT, AND CLOSE TORQUE LIMIT, SEE SHEETS E-700 SERIES
PROVIDE PRESS TO TEST INDICATORS FOR GATE RECESS, GATES MITERED,
CONTRACTOR INSTALLED EQUIPMENT.
AND CLOSED TORQUE SWITCHES ARE GOVERMENT FURNISHED
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. OPEN TORQUE
BACK TO RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. ALL DEVICES,
PROVIDE OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHES CABLING
RECEPTACLES FOR LOW SPEED AND HIGH SPEED.
CORD AND CONNECTOR THAT MATES WITH EXISTING INTERLOCK
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. PROVIDE NEW
CONDUCTOR CABLING TO EXISTING INTERLOCK RECEPTACLES. ALL DEVICES,
PROVIDE NEW MOTOR HIGH SPEED AND LOW SPEED WINDING FLEXIBLE
MOTOR CONTROLLER CABINET TO MOTOR WINDING HEATER.
BE PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL
CONNECT NEW MOTOR WINDING HEATER TO EXISTING CIRCUIT. ALL
MOTOR CONTROLLER CABINET TO AC BRAKE HEATER.
PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL BE
CONNECT NEW AC BRAKE HEATER TO EXISTING CIRCUIT. ALL DEVICES,
FOR ROTARY CAM LIMIT SWITCH HEATER CIRCUIT.
PROVIDE NEW CONDUIT, CONDUTOR, DEVICES AND CONNECTIONS EQUIPMENT.
SWITCHES ARE GOVERMENT FURNISHED CONTRACTOR INSTALLED
REQUIRED FOR MODIFICATION SHALL BE PROVIDED. ROTARY CAM LIMIT
ROTARY CAM LIMIT SWITCHES. ALL DEVICES, CABLES AND CONDUCTORS
THE MOTOR CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW MOTOR
CONDUCTORS AS NECESSARY.
CONNECTED TO EXISTING CABLING. PROVIDE NEW CONDUIT, FITTINGS, AND
PROVIDE NEW AC BRAKE HEATER. AC BRAKE HEATER CIRUIT SHALL BE
EQUIPMENT.
NEW AC BRAKE IS GOVERMENT FURNISHED CONTRACTOR INSTALLED
FOR INTEGRATING NEW AC BRAKE INTO EXISTING LOCK CONTROL SYSTEM.
BRAKE. PROVIDE MODIFCATIONS, CONDUIT, CONDUCTORS, ETC REQUIRED
THE MITER GATE CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW AC
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. PROVIDE OPERATIONS
DISCONNECT OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHS BACK TO
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE AND PROPERLY DISPOSE OF OFF SITE. PROVIDE OPERATIONS
DISCONNECT HIGH SPEED AND LOW SPEED WINDING CONNECTION BACK TO
REFUSAL CONTRACTOR SHALL PROPERLY DISPOSE OF OFF SITE.
DISCONNECTED AND OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH
ROTARY CAM LIMITING LIMIT SWITCHES ARE TO BE RECORDED AND
SHALL PROPERLY DISPOSE OF OFF SITE.
OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR
DC BRAKE AND BRAKE CONTROLLER ARE TO BE DISCONNECTED AND
EXISTING MITER GATE MOTOR CONTROLLER TO REMAIN. 2.
LEVER-ARM ACTUATION TO MATCH EXISTING OPERATION.
WITH NEW LIMIT SWITCH BOLT PATTERNS AS REQUIRED TO MAKE PROPER
EXISTING OPERATION. FABRICATE NEW STAINLESS STEEL MOUNTING PLATE
EXISTING STRUT ARM LIMIT SWITCHES AND ADJUST SETTINGS TO MATCH
SWITCHES DURING INSTALLATION OF NEW STRUT ARM. RECONNECT
POSITIVE-BREAK CONTACTS. DISCONNECT AND PROTECT STRUT-ARM LIMIT
LIMIT SWITCH, ADJUSTABLE LEVER, NEMA 4, AND IP67; DPDT, SNAP ACTION,
WIRING). THE LIMIT SWITCHES ARE: HONEYWELL SZL-VL-S SIDE ROTARY
PER LOCK)). (SEE REFERENCE SHEETS FOR DIMENSIONS, MOUNTING, AND
EACH OF FOUR MITER GATE LEAVES (16 LEVER-ARM LIMIT SWITCHES TOTAL
EXISTING MITER-GATE STRUT-ARM LIMIT SWITCHES ((4) LIMIT SWITCHES FOR 1.
SHEET KEYNOTES
VALVE MACHINERYVMR
GATE MACHINERYGMR
HYDRAULIC VALVEHV
CONTROL STATIONCS
LOWER LEFTLL
UPPER LEFTUL
LOWER RIGHTLR
UPPER RIGHTUR
LLCS
LLHV
LLGMR
A1
PLAN - DOWNSTREAM LANDWALL
SCALE: 1/8"=1'-0" 0 8'4' 16'
ABBREVIATIONS
E-502
G1
E-503
S I
D
S O
L
IC
IT
A
T
IO
N
M A
R S
E
IL
L E
S A
N D
S T
A R
V E
D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L
E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D
D A
M
S T
A R
V E
D R
O C
K L
O C
K A
N D
D A
M
IL
L
IN
O
IS
R
IV
E
R B
A S
IN
/0
/1
R O
C K
I S
L A
N D
IL
L
IN
C K
I S
L A
N D
D
IS
T R
B
A R
T E
K
D O
W N
S T
R E
A M
R
IV
E R
W A
L L
M
IT
E R
G A
T E
E L
E C
T R
IC
A
L
P L
A N
E-105
T B
U L
L A
R D
N
V E
E N
A U
G
N D
S H
E E
T K
E Y
N O
T E
S R
E V
IS
IW
P
R O
J
D T
E P
E N
MAR-MACH
W
E K
B
WIRING
SWITCHES AND
STRUT-ARM LIMIT
MITER GATE
ALLOW FULL GATE MOTION.
CONNECTION TO STRUT-ARM LIMIT SWITCH TO
4 FT SECTION OF RETRACTING SOW CORD FOR
CONTROLS CONSOLE
LOCATION OF
CONTROL STAND
ELEVATED
ENCASED DUCT BANK
EXISTING CONCRETE-
LOCATED IN QUOIN AREA
CONDUIT, 4' MINIMUM SECTION
STAINLESS STEEL EXTRA FLEX-
CONCRETE CABLE TROUGH
EXISTING ABOVE GROUND
CONTROLLER
MITER GATE MOTOR
EQUIPMENT.
THE CONTROL AND EXISTING
ELEVATED JUNCTION BOXES BETWEEN
PROXIMITY SWITCH
MITER GATE FULLY RECESSED
TO OPPOSING GATE
END OF GATE MITER
MITER PROXIMITY SWITCH
CONSTRUCTION)
(PROTECT DURING
LIGHT FIXTURE
POLE MOUNTED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SEE REFERENCE DRAWINGS FOR EXISTING CABLES AND CONNECTIONS. 2.
SEE NOTES ON SHEET E-001.1.
GENERAL SHEET NOTES
N
ON LANDWALL GATE.
ELEMENTARY CONTROL DIAGRAMS. CONDUIT AND CONDUCTORS LOCATED
THRU E-505 FOR PROXIMITY LIMIT SWITCH MOUNTING AND E-700 SERIES FOR
PROVIDE "PROOF OF MITER" PROXIMITY LIMIT SWITCH ASSEMBLY, SEE E-502 6.
CONDUIT AND GALLERY AS REQUIRED.
CABLE FROM SENSOR TO RELAY IN CONTROL CONSOLE THRU EXISTING
ELEMENTARY CONTROL DIAGRAMS. ROUTE NEW 6 CONDUCTOR CONTROL
THRU E-505 FOR PROMITY SWITCH MOUNTING. SEE E-700 SERIES FOR
PROVIDE MITER GATE RECESSED PROXIMITY SENSOR AND RELAY. SEE E-502 5.
DEVICES, CONDUIT AND CONDUCTORS REQUIRED.
AND E-700 SERIES FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL
EXISTING CONTROL CONSOLE TO BE MODIFIED, SEE SHEETS E-512, E-513, 4.
LIMIT SWITCH TO ALLOW FULL GATE MOTION.
4 FT SECTION OF RETRACTING SOW CORD FOR CONNECTION TO STRUT-ARM 3.
CONSOLE. ROUTE CONDUCTORS THRU CONDUIT AND GALLERY.
CABLES FROM EXISTING MITER GATE MOTOR CONTROLLER TO CONTROL
AND CONDUCTORS REQUIRED. PROVIDE TWO 8-CONDUCTOR CONTROL
FOR CONTROL MODIFICATIONS. PROVIDE ADDITIONAL DEVICES, CONDUIT
OPEN TORQUE LIMIT, AND CLOSE TORQUE LIMIT, SEE SHEETS E-700 SERIES
PROVIDE PRESS TO TEST INDICATORS FOR GATE RECESS, GATES MITERED,
CONTRACTOR INSTALLED EQUIPMENT.
AND CLOSED TORQUE SWITCHES ARE GOVERMENT FURNISHED
CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED. OPEN TORQUE
BACK TO RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. ALL DEVICES,
PROVIDE OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHES CABLING
INTERLOCK RECEPTACLES FOR LOW SPEED AND HIGH SPEED.
PROVIDE NEW CORD AND CONNECTOR THAT MATES WITH EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED SHALL BE PROVIDED.
CONDUCTOR CABLING TO EXISTING INTERLOCK RECEPTACLES. ALL
PROVIDE NEW MOTOR HIGH SPEED AND LOW SPEED WINDING FLEXIBLE
MOTOR CONTROLLER CABINET TO MOTOR WINDING HEATER.
BE PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
DEVICES, CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL
CONNECT NEW MOTOR WINDING HEATER TO EXISTING CIRCUIT. ALL
MOTOR CONTROLLER CABINET TO AC BRAKE HEATER.
PROVIDED. PROVIDE NEW CONDUCTORS AND CONDUIT FROM EXISTING
CABLES AND CONDUCTORS REQUIRED FOR MODIFICATION SHALL BE
CONNECT NEW AC BRAKE HEATER TO EXISTING CIRCUIT. ALL DEVICES,
FOR ROTARY CAM LIMIT SWITCH HEATER CIRCUIT.
PROVIDE NEW CONDUIT, CONDUTOR, DEVICES AND CONNECTIONS EQUIPMENT.
SWITCHES ARE GOVERMENT FURNISHED CONTRACTOR INSTALLED
REQUIRED FOR MODIFICATION SHALL BE PROVIDED. ROTARY CAM LIMIT
ROTARY CAM LIMIT SWITCHES. ALL DEVICES, CABLES AND CONDUCTORS
THE MOTOR CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW MOTOR
CONDUCTORS AS NECESSARY.
CONNECTED TO EXISTING CABLING. PROVIDE NEW CONDUIT, FITTINGS, AND
PROVIDE NEW AC BRAKE HEATER. AC BRAKE HEATER CIRUIT SHALL BE
EQUIPMENT.
NEW AC BRAKE IS GOVERMENT FURNISHED CONTRACTOR INSTALLED
FOR INTEGRATING NEW AC BRAKE INTO EXISTING LOCK CONTROL SYSTEM.
BRAKE. PROVIDE MODIFCATIONS, CONDUIT, CONDUCTORS, ETC REQUIRED
THE MITER GATE CONTROLLER SHALL BE MODIFIED TO WORK WITH NEW AC
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE/MOTOR CONTROLLER ENCLOSURE. PROVIDE OPERATIONS
DISCONNECT OPEN TORQUE AND CLOSED TORQUE LIMIT SWITCHS BACK TO
PROPERLY DISPOSE OF OFF SITE.
WITH FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR SHALL
RECEPTACLE AND PROPERLY DISPOSE OF OFF SITE. PROVIDE OPERATIONS
DISCONNECT HIGH SPEED AND LOW SPEED WINDING CONNECTION BACK TO
REFUSAL CONTRACTOR SHALL PROPERLY DISPOSE OF OFF SITE.
DISCONNECTED AND OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH
ROTARY CAM LIMITING LIMIT SWITCHES ARE TO BE RECORDED AND
SHALL PROPERLY DISPOSE OF OFF SITE.
OPERATIONS GIVEN FIRST RIGHT OF REFUSAL. WITH REFUSAL CONTRACTOR
DC BRAKE AND BRAKE CONTROLLER ARE TO BE DISCONNECTED AND
EXISTING MITER GATE MOTOR CONTROLLER TO REMAIN. 2.
LEVER-ARM ACTUATION TO MATCH EXISTING OPERATION.
WITH NEW LIMIT SWITCH BOLT PATTERNS AS REQUIRED TO MAKE PROPER
EXISTING OPERATION. FABRICATE NEW STAINLESS STEEL MOUNTING PLATE
EXISTING STRUT ARM LIMIT SWITCHES AND ADJUST SETTINGS TO MATCH
SWITCHES DURING INSTALLATION OF NEW STRUT ARM. RECONNECT
POSITIVE-BREAK CONTACTS. DISCONNECT AND PROTECT STRUT-ARM LIMIT
LIMIT SWITCH, ADJUSTABLE LEVER, NEMA 4, AND IP67; DPDT, SNAP ACTION,
WIRING). THE LIMIT SWITCHES ARE: HONEYWELL SZL-VL-S SIDE ROTARY
PER LOCK)). (SEE REFERENCE SHEETS FOR DIMENSIONS, MOUNTING, AND
EACH OF FOUR MITER GATE LEAVES (16 LEVER-ARM LIMIT SWITCHES TOTAL
EXISTING MITER-GATE STRUT-ARM LIMIT SWITCHES ((4) LIMIT SWITCHES FOR 1.
SHEET KEYNOTES
VALVE MACHINERYVMR
GATE MACHINERYGMR
HYDRAULIC VALVEHV
CONTROL STATIONCS
LOWER LEFTLL
UPPER LEFTUL
LOWER RIGHTLR
UPPER RIGHTUR
LRCS
LRHV
LRGMR
A1
PLAN - DOWNSTREAM RIVERWALL
SCALE: 1/8"=1'-0"
GENERAL SHEET NOTES
0 8'4' 16'
E-504
G1
E-505
B
C F
E
D
1MS OL
G
H
MOTOR
25 HP
J
OL1MS
1MS
1CR
1 2
4KW IN RESERVOIR OIL HTR.4KW
L1 L2 L3
BR6 BR6
1 2 OF OF
OF
CF CF
CF
PR-F1 PR-F2
T11
T12T13
T1
T2T3
CS CS
CS
OS
SEE ELEM. DIAGRAM
CONTROL CIRCUIT,
480 VAC
OL'S
OS
OS
OL'S
SLOW WINDINGSFAST WINDINGS
MOTOR
BRAKE
TO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
IS
S
U E D
A T
E
S
IZ
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
A N
S I
D
S O
L
IC
IT
A T
IO
N
M A
R S
E
IL
L E
S A
N D S
T A
R V
E D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D D
A M S
T A
R V
E D R
O C
K L
O C
K A
N D D
A M
IL
L
IN
O
IS
R
IV
E R B
A S
IN
/0
/1
R O
C K I S
L A
N D
IL
L
IN
O
IS
C K I S
L A
N D D
IS
T R
B A
R T
T O
R W
IR
IN
G
D
IA
G R
A M
S
E-601
T
B U
L L
A R
D
N
V E
E N
A U
G
N D
S
H E
E T K
E Y
N O
T E
S R
E V
IS
IW
P R
O J
D T
E P
E N
MAR-MACH
W E
K
B
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A1
SCALE: NTS
EXISTING HYDRAULIC VALVE PUMP WIRING
A11
SCALE: NTS
DETAIL: PHOTO OF TYPICAL UR MITER GATE CONTROLLER
F1
SCALE: NTS
EXISTING GATE MOTOR POWER WIRING DIAGRAM
CONTROLLER MAY VARY.
CONTROLLER SHOWN IN DETAIL A11 IS TYPICAL. ACTUAL CONFIGURATION OF 2.
SEE LADDER LOGIC DIAGRAMS ON SHEETS E-701 THROUGH E-704.1.
GENERAL NOTES
SHEET KEYNOTES
AND RELAYS NOT SHOWN ON THIS SHEET)
ASSOCIATED WITH COIL INRUSH. SEE DETAIL F1. (MOTOR STARTER COILS
AND NOT THE LARGER CONTACTOR COIL TO MINIMIZE VOLTAGE DROP
AS THE RELAY COIL LOAD IS RUN THROUGHT CONTROL STATION CABLING
CONTACT SHALL BE USED TO PICK UP AND RELEASE CONTACTOR COILS SO
PROVIDE INDUSTRIAL RELAY (A11) FOR EACH CONTACTOR COIL. RELAY 6.
SOLDERLESS BOX LUG, RAIL MOUNT, WITH END BARRIERS AND CLAMPS.
EXISTING TERMINAL BLOCK ENCLOSURE, SS NEMA 4X (QTY 30), 600V, 60A, 5.
CONTROL CIRCUIT.
FOR NEW AC BRAKE CONTROLLER INTO MITER GATE MOTOR CONTROLLER
DISPOSED OF. PROVIDE ALL CONDUCTORS, CONNECTIONS, AND CONDUIT
EXISTING DC BREAK CONTROLLER TO BE DISCONNECTED AND PROPERLY 4.
COMPONENTS.
SHEET. CONTRACTOR SHALL PROTECT MITER GATE STARTERS AND
WITH OPEN AND CLOSE STARTERS, NEMA SIZE 3. SEE DETAIL F1 ON THIS
EXISTING MITER GATE MOTOR STARTER ENCLOSURE, TWO SPEED STARTER, 3.
4X CAP.
PROVIDE TYPICAL PLUG ARKTIGHT/POWERTITE ACP 1034CD WITH MATCHING 2.
MATCHING 4X CAP.
PROVIDE TYPICAL RECEPTACLE ARKTIGHT/POWERTITE WSR 103542 WITH 1.
DRAWINGS E-701 THROUGH E-704.
REFERENCE ONLY. SEE ALSO LADDER LOGIC
NOTE: MOTOR WIRING DETAILS SHOWN FOR
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
IS
S
U E D
A T
E
S
IZ
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
A N
S I
D
S O
L
IC
IT
A T
IO
N
M A
R S
E
IL
L E
S A
N D S
T A
R V
E D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D D
A M S
T A
R V
E D R
O C
K L
O C
K A
N D D
A M
IL
L
IN
O
IS
R
IV
E R B
A S
IN
/0
/1
R O
C K I S
L A
N D
IL
L
IN
O
IS
C K I S
L A
N D D
IS
T R
B A
R T
W N
S T
R E
A M R
IV
E R
W A
L L
L A
D D
E R L
O G
IC
D
IA
G R
A M
S
E-701
T
B U
L L
A R
D
N
V E
E N
A U
G
N D
R
E V
IS
E D W
O R
K A
R
IW
P R
O J
D T
E P
E N
MAR-MACH
W E
K
B
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A1
SCALE: NTS
DOWNSTREAM RIVERWALL CONTROLS - LADDER LOGIC DIAGRAM
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
36-120 78-43
77-51
77-52
54-51
54-52
78-38
55-43
55-38
CC
CO CC
CO
CO
CC
CL
CH
TD
TD
CH
CL
317-1 317-2
RLS
LRG
TDRLS
LRG
R2
R3
G
G
R
R
(30)
(20)
(20)
(30)
(60) (50)
(60) (40)
SS-LR-14
IMS
CLOSE
R2
R3
M
M
R2
R3
OPEN
CLOSE
W
LS
LS
R
G
W
W
2TC
1TC
OL OL
78-42
78-41 77-200
77-200
PL-LR-10
PL-LR-11
"FULL OPEN"
LOWER RIGHT GATE
"FULL CLOSED"
LOWER RIGHT GATE
OPEN
OL OL
"POWER ON" INDICATOR
LOWER RIGHT VALVE PUMP MOTOR
F U
INDICATOR LIGHT
CABINET HEATER "ON"
LOWER RIGHT VALVE
CABINET HEATER
LOWER RIGHT VALVE
"ON" INDICATOR
OIL RESERVOIR HEATER
LOWER RIGHT VALVE
OPEN" INDICATOR
LOWER RIGHT VALVE "FULL
OPEN" INDICATOR
LOWER RIGHT VALVE "FULL
CLOSED" INDICATOR
LOWER RIGHT VALVE "FULL
CLOSED" INDICATOR
LOWER RIGHT VALVE "FULL
77-53 77-200
77-54 77-200
PL-LR-17
PL-LR-18
FU3
FU4
(150)
(160)
3LS
4LS
ICR
1LS
2LS
(CONTINUED AT RIGHT)
(CONTINUED FROM LEFT)
MOTOR HEATERS
LOWER RIGHT VALVE
OPEN SOLENOID A
LOWER RIGHT VALVE
CLOSE SOLENOID B
LOWER RIGHT VALVE
POWER FROM CONTROL HOUSE SWITCHGEAR
SLS
LRG
SLS
LRG
RLS
LRG
RLS
LRG
RLS
LRG
RLS
LRG
36-120
JS-LL-3
JS-LR-13
JS-LR-13
JS-LL-3
77-200
67-200
(40,50)
LOW TO HIGH SPEED
ADJUSTABLE DELAY FROM
LOWER RIGHT GATE
JS-LL-5
JS-LR-20
JS-LR-20
JS-LL-5
R1
LRV
LR
LRGO
LR
LRGC
LL
LRGO
LL
LRGC
LR
LRVO
LR
LRVC
LL
LRVO
LL
LRVC
LRRR
LGMR
LL
LRGO
LL
LRGC
LR
LLVC
LL
LLVO
LL
LLVC
LR
LRVO
LR
LRVC
LL
LRVO
LL
LRVC
LR
LLVO
36-120
LR
LLGC
LL
LLGO
LL
LLGC
LR
LRGO
LR
LRGC
LL
LRGO
LL
LRGC
LR
LLGO
67-120
67-120
LR
LRVO
LR
LRVC
LL
LRVO
LL
LRVC
67-120
(190)
(195)
(360)
(370)
(340)
(350)
(380)
(390)
(340)
(350)
(380)
(390)
(320)
(330)
(360)
(370)
(150)
(160)
(90, 210)
OPEN LOWER RIGHT VALVE
(100, 220)
CLOSE LOWER RIGHT VALVE
(1180)
(1190)
(1140)
(1150)
(1160)
(1170)
(1120)
(1130)
(20, 150, 970)
RIGHT GATE
OPEN LOWER
(30, 160, 980)
RIGHT GATE
CLOSE LOWER
(20, 150, 840)
RIGHT VALVE
OPEN LOWER
(30, 160, 850)
RIGHT VALVE
CLOSE LOWER
(40, 170, 950)
RIGHT GATE
OPEN LOWER
(50, 180, 960
RIGHT GATE
CLOSE LOWER
(40, 170, 820)
RIGHT VALVE
OPEN LOWER
(50, 180, 830)
RIGHT VALVE
CLOSE LOWER
LCPR (SEE SHEET E-707 - LINE #50)
(SEE SHEET E-707 - LINE #10)
VALVE INTERLOCK RELAY
SHEET E-611)
(SEE HYDRAULIC PUMP WIRING,
MOTOR "POWER ON" SOLENOID
LOWER RIGHT VALVE PUMP
(30,40)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
OPEN LOWER RIGHT GATE
(20,50)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
CLOSE LOWER RIGHT GATE
(50)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
LOWER RIGHT GATE LOW SPEED
(40)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
LOWER RIGHT GATE HIGH SPEED
WIRING, SHEET E-611)
(SEE HYDRAULIC PUMP
RESERVOIR HEATER
LOWER RIGHT VALVE OIL
CC AUX
CO AUX
W
PL-LR-X
W
PL-LL-X
MOTOR RUNNING
LOWER RIGHT GATE
CONTROL CONSOLE)
RUNNING (LOWER LEFT
LOWER RIGHT GATE MOTOR
LS
R
LRRR
W
550, 1350)
RECESS RELAY (20,
LOWER RIGHT
(20)
LIMIT RELAY
CLOSE TORQUE
(30)
LIMIT RELAY
OPEN TORQUE
CTLS CTLR
PL-LR-X
W
W
PL-LR-X
OTLS
R390
R
OTLR
(330)
LR
LRGC
(320)
LR
LRGO
CTLR
(390)
OTLR
(395)
LGMR
(195)
UGMR
(595)
LRRR
LGMR
OPEN TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)OTLS
CLOSED TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)CTLS
OTHER
CONTROL STAND CONSOLES
CONTROL HOUSE
GATE CONTROLS
VALVE CONTROLS
EQUIPMENT LOCATION
LEGEND
USED.
PERMITTED. PROVIDE LABELING OF ALL TERMINALS AND CONDUCTORS
CONDUCTORS AS REQUIRED, USE OF SPARE CROSSOVER CONDUCTOR IS
PRESENT LOGIC. MAKE ADDITION INDICATED WITHIN BOXES. PROVIDE NEW
NOTE: THIS DRAWING SHOWS THE BEST KNOWN INTERPRETATION OF 1.
GENERAL SHEET NOTES
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
IS
S
U E D
A T
E
S
IZ
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
A N
S I
D
S O
L
IC
IT
A T
IO
N
M A
R S
E
IL
L E
S A
N D S
T A
R V
E D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D D
A M S
T A
R V
E D R
O C
K L
O C
K A
N D D
A M
IL
L
IN
O
IS
R
IV
E R B
A S
IN
/0
/1
R O
C K I S
L A
N D
IL
L
IN
O
IS
C K I S
L A
N D D
IS
T R
B A
R T
U P
S T
R E
A M R
IV
E R
W A
L L
L A
D D
E R L
O G
IC
D
IA
G R
A M
S
E-702
T
B U
L L
A R
D
N
V E
E N
N D
R
E V
IS
E D W
O R
K A
R
IW
P R
O J
D T
E P
E N
MAR-MACH
W E
K
B
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A1
SCALE: NTS
UPSTREAM RIVERWALL CONTROLS - LADDER LOGIC DIAGRAM
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CC
CO CC
CO
CO
CC
CL
CH
TD
TD
CH
CL
309-1 309-2
RLS
URG
TDRLS
URG
R2
R3
G
R1
G
R
R
JS-UL-3
JS-UR-13
JS-UR-13
JS-UL-3
SS-LR-14
IMS
CLOSE
JS-UR-20
JS-UR-20
JS-UL-5
JS-UL-5
R2
R3
M
M
R2
R3
OPEN
CLOSE
W
LS
LS
R
G
W
W
2TC
1TC
OL OL
75-64
75-63 51-200
51-200
PL-UR-10
PL-UR-11
"FULL OPEN"
UPPER RIGHT GATE
"FULL CLOSED"
UPPER RIGHT GATE
OPEN
OL OL
"POWER ON" INDICATOR
PUMP MOTOR
UPPER RIGHT VALVE
F U
INDICATOR LIGHT
CABINET HEATER "ON"
UPPER RIGHT VALVE
CABINET HEATER
UPPER RIGHT VALVE
"ON" INDICATOR
OIL RESERVOIR HEATER
UPPER RIGHT VALVE
"FULL OPEN" INDICATOR
UPPER RIGHT VALVE
"FULL OPEN" INDICATOR
UPPER RIGHT VALVE
"FULL CLOSED" INDICATOR
UPPER RIGHT VALVE
"FULL CLOSED" INDICATOR
UPPER RIGHT VALVE
51-26 51-200
51-28 51-200
PL-UR-15
PL-UR-16
(430)
(420)
(420) (460) (450)
(430) (460) (440)
FU3
FU4
(CONTINUED FROM LEFT)
(CONTINUED AT RIGHT)
3LS
4LS
1LS
2LS
(550)
(560)
ICR
MOTOR HEATERS
UPPER RIGHT VALVE
OPEN SOLENOID A
UPPER RIGHT VALVE
CLOSE SOLENOID B
UPPER RIGHT VALVE
POWER FROM CONTROL HOUSE SWITCHGEAR
URV
RLS
URG
RLS
URG
(440, 450)
LOW TO HIGH SPEED
ADJUSTABLE DELAY FROM
UPPER RIGHT GATE
75-110
51-200
64-200
UR
URGO
UR
URGC
UL
URGO
UL
URGC
UR
URVO
UR
URVC
UL
URVO
UL
URVC
64-110
75-110 70-20
70-17
50-20
50-17
SLS
URG
SLS
URG
RLS
URG
RLS
URG
UR
ULVC
UL
ULVO
UL
ULVC
UR
URVO
UR
URVC
UL
URVO
UL
URVC
UR
ULVO
64-110
(720)
(730)
(760)
(770)
(740)
(750)
(780)
(790)
UR
URGO
UR
URGC
UL
URGO
UL
URGC
75-61
75-62
53-61
53-62
75-110
UR
ULGC
UL
ULGO
UL
ULGC
UR
URGO
UR
URGC
UL
URGO
UL
URGC
UR
ULGO
64-110
UR
URVO
UR
URVC
UL
URVO
UL
URVC
(740)
(750)
(780)
(790)
(720)
(730)
(760)
(770)
(550)
(560)
(490, 610)
RIGHT VALVE
OPEN UPPER
(500, 620)
RIGHT VALVE
CLOSE UPPER
(1580)
(1590)
(1540)
(1550)
(1560)
(1570)
(1520)
(1530)
(420, 550, 1370)
RIGHT GATE
OPEN UPPER
(430, 560, 1380)
RIGHT GATE
CLOSE UPPER
(420, 550, 1240)
RIGHT VALVE
OPEN UPPER
(430, 560, 1250)
RIGHT VALVE
CLOSE UPPER
(440, 570, 1350)
RIGHT GATE
OPEN UPPER
(450, 580, 1360)
RIGHT GATE
CLOSE UPPER
(440, 570, 1220)
RIGHT VALVE
OPEN UPPER
(450, 580, 1230)
RIGHT VALVE
CLOSE UPPER
UCPR (SEE SHEET E-707, LINE #10)
(430, 440)
DIAGRAM, SHEET E-611)
(SEE GATE WIRING
OPEN UPPER RIGHT GATE
(420, 450)
DIAGRAM, SHEET E-611)
(SEE GATE WIRING
CLOSE UPPER RIGHT GATE
(450)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
UPPER RIGHT GATE LOW SPEED
(440)
SHEET E-611)
(SEE GATE WIRING DIAGRAM,
UPPER RIGHT GATE HIGH SPEED
PUMP WIRING, SHEET E-611)
SOLENOID (SEE HYDRAULIC
MOTOR "POWER ON"
UPPER RIGHT VALVE PUMP
WIRING, SHEET E-611)
(SEE HYDRAULIC PUMP
RESERVOIR HEATER
UPPER RIGHT VALVE OIL
(SEE SHEET E-707, LINE #50)
VALVE INTERLOCK RELAY
(420)
LIMIT RELAY
CLOSE TORQUE
(430)
LIMIT RELAY
OPEN TORQUE
CTLS
CTLR
PL-UR-X
W
W
PL-UR-X
OTLS
R
R
OTLR
AUX CO
AUX CC
R
PL-UR-9
PL-UL-X
R
MOTOR RUNNING
UPPER RIGHT GATE
CONSOLE)
(UPPER LEFT CONTROL
MOTOR RUNNING
UPPER RIGHT GATE
PL-UR-X
W
R
URRR
UGMR
(420)
RECESS RELAY
UPPER RIGHT
LS
CTLR
OTLR UGMR
URRR
(790)
(795)
(590)
(595)
LGMR
(195)
UGMR
(595)
LRRR
(190)
LLRR
(985)
UVBR
(2000)
URRR
UGMR
OPEN TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)OTLS
CLOSED TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)CTLS
OTHER
CONTROL STAND CONSOLES
CONTROL HOUSE
GATE CONTROLS
VALVE CONTROLS
EQUIPMENT LOCATION
LEGEND
USED.
PERMITTED. PROVIDE LABELING OF ALL TERMINALS AND CONDUCTORS
CONDUCTORS AS REQUIRED, USE OF SPARE CROSSOVER CONDUCTOR IS
PRESENT LOGIC. MAKE ADDITION INDICATED WITHIN BOXES. PROVIDE NEW
NOTE: THIS DRAWING SHOWS THE BEST KNOWN INTERPRETATION OF 1.
GENERAL SHEET NOTES
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
IS
S
U E D
A T
E
S
IZ
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
A N
S I
D
S O
L
IC
IT
A T
IO
N
M A
R S
E
IL
L E
S A
N D S
T A
R V
E D R
O C
K M
A C
H
IN
E R
Y R
E H
A B
IL
IT
A T
IO
N
L A
S A
L L E C
O U
N T
Y
IL
M A
R S
E
IL
L E
S L
O C
K A
N D D
A M S
T A
R V
E D R
O C
K L
O C
K A
N D D
A M
IL
L
IN
O
IS
R
IV
E R B
A S
IN
/0
/1
R O
C K I S
L A
N D
IL
L
IN
O
IS
C K I S
L A
N D D
IS
T R
B A
R T
W N
S T
R E
A M L
A N
D W
A L L
L A
D D
E R L
O G
IC
D
IA
G R
A M
S
E-703
T
B U
L L
A R
D
N
V E
E N
A U
G
N D
R
E V
IS
E D W
O R
K A
R
IW
P R
O J
D T
E P
E N
MAR-MACH
W E
K
B
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A1
SCALE: NTS
DOWNSTREAM LANDWALL CONTROLS - LADDER LOGIC DIAGRAM
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS CONTRACT. WORK OUTSIDE THIS BOX IS EXISTING.
WORK IN THIS BOX SHALL BE PROVIDED UNDER THIS
OPEN TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)OTLS
CLOSED TORQUE LIMIT SWITCH (LOCAL MITER GATE LEAF)CTLS
OTHER
CONTROL STAND CONSOLES
CONTROL HOUSE
GATE CONTROLS
VALVE CONTROLS
EQUIPMENT LOCATION
LEGEND
USED.
PERMITTED. PROVIDE LABELING OF ALL TERMINALS AND CONDUCTORS
CONDUCTORS AS REQUIRED, USE OF SPARE CROSSOVER CONDUCTOR IS
PRESENT LOGIC. MAKE ADDITION INDICATED WITHIN BOXES. PROVIDE NEW
NOTE: THIS DRAWING SHOWS THE BEST KNOWN INTERPRETATION OF 1.
GENERAL SHEET NOTES
CC
CO CC
CO
CO
CC
CL
CH
TD
TD
CH
CL
RLS
LLG
TDRLS
LLG
R2
R3
G
R1
G
R
R
SS-LR-14
IMS
CLOSE
R2
R3
M
M
R2
R3
OPEN
CLOSE
W
LS
LS
R
G
W
W
2TC
1TC
OL OL
57-34
57-32 77-200
77-200
PL-LL-8
PL-LL-9
"FULL OPEN"
LOWER LEFT GATE
"FULL CLOSED"
LOWER LEFT GATE
OPEN
OL OL
"POWER ON" INDICATOR
PUMP MOTOR
LOWER LEFT VALVE
F U
CABINET HEATER
LOWER LEFT VALVE
56-68 77-200
56-69 77-200
PL-LR-15
PL-LR-16
(830)
(820)
(820)
(830)
(860) (850)
(860) (840)
36-1 36-2
INDICATOR LIGHT
CABINET HEATER "ON"
LOWER LEFT VALVE
"ON" INDICATOR
OIL RESERVOIR HEATER
LOWER LEFT VALVE
"FULL OPEN" INDICATOR
LOWER LEFT VALVE
"FULL OPEN" INDICATOR
LOWER LEFT VALVE
"FULL CLOSED" INDICATOR
LOWER LEFT VALVE
"FULL CLOSED" INDICATOR
LOWER LEFT VALVE
(CONTINUED AT RIGHT)
FU3
(CONTINUED FROM LEFT)
MOTOR HEATERS
UPPER RIGHT VALVE
FU4
3LS
4LS
ICR
1LS
2LS
(950)
(960)
OPEN SOLENOID A
LOWER LEFT VALVE
CLOSE SOLENOID B
LOWER LEFT VALVE
POWER FROM CONTROL HOUSE SWITCHGEAR
LLV
RLS
LLG
RLS
LLG
(840, 850)
LOW TO HIGH SPEED
ADJUSTABLE DELAY FROM
LOWER LEFT GATE
JS-LL-2
JS-LR-12
JS-LR-12
JS-LL-2
JS-LR-19
JS-LR-19
JS-LL-4
JS-LL-4
77-120
77-200
67-200
LL
LLGO
LL
LLGC
LR
LLGO
LR
LLGC
LL
LLVO
LL
LLVC
LR
LLVO
LR
LLVC
67-120
77-120 57-35
57-29
68-35
68-29
SLS
LLG
SLS
LLG
RLS
LLG
RLS
LLG
LL
LLVC
LR
LLVO
LR
LLVC
LL
LRVO
LL
LRVC
LR
LRVO
LR
LRVC
LL
LLVO
67-120
(1120)
(1130)
(1160)
(1170)
(1140)
(1150)
(1180)
(1190)
LL
LLGO
LL
LLGC
LR
LLGO
LR
LLGC
56-66
56-67
66-66
66-67
77-120
LL
LLGC
LR
LLGO
LR
LLGC
LL
LRGO
LL
LRGC
LR
LRGO
LR
LRGC
LL
LLGO
67-120
LL
LLVO
LL
LLVC
LR
LLVO
LR
LLVC
(1140)
(1150)
(1180)
(1190)
(1120)
(1130)
(1160)
(1170)
(950)
(960)
(890, 1010)
LEFT VALVE
OPEN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .