VOL_1_21B0007_Plans_AM0003.pdf
PDF 359 KB Posted
- Attached to
- MNA-LGA-LMA Headgate Rep Pit Upgrades Federal contract opportunity
- Solicitation number
- W912EF21B0007
About this file
This document package includes technical specifications and drawings for upgrades to the powerhouse gate repair pit at the MNA-LGA-LMA Headgates on the Snake River. The specifications call for upgrades including two-stage extending platforms, industrial light fixtures, guard rails, and other repairs. The solicitation number for this project is W912EF21B0007. The specifications provide details on the design and materials for the extending platforms, which include stationary and movable stages, as well as guard rails and safety elements. Industrial light fixtures are also specified, with details on lumen output, voltage, enclosure type and other technical requirements. The drawings depict sections and elevations of the platform designs.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 5
SECTION 4
SECTION 3
SECTION 2
SECTION 1
SECTION 1
SECTION 2
SECTION 3
SECTION 4
SECTION 5
CHAIN DRIVE ROD (TYP)
A N
S I
D
W
L L
A W
A L
L A
D
IS
T R
IC
T
F
IL
E N
O
L
IT
T L
E G
O O
S E
L O
C K
A N
D D
A M
S N
A K
E R
IV
E
R O
R E
G O
N W
A S
H
IN
G T
O N
A N
D I
D A
H O
P O
W E
R H
O U
S E
G A
T E
R E
P A
IR
P
IT
U
P G
R A
D E
S
P
A U
T H
D K
L O
E W
E R
D K
L O
E W
E R
M-508
L G
P -1
-3 -3
/1
L L
A W
A L
L A
W
A S
H
IN
G T
O N
N
R
D A
V E
FINAL
VOLUME 1
K E
V
IN
R E
N S
H A
W
P .E
W
E F
B
T
O S
T A
G E
E X
T E
N D
E D
P L
A T
F O
R M
S T
A G
E
P L
A T
F O
R M
A S
S E
M B
L Y
A4
FRONT ELEVATION: STAGE 2 PLATFORM
SCALE: NTS
E1
SCALE: NTS
SECTION: TWO STAGE PLATFORM DETAIL
/4 /2
M
O D
IF
IE
D E
X T
E N
D E
D W
A L
K W
A Y
C A
L L
O U
T
/4
/2
R E
M O
V E
D E
X T
R A
C H
A
IN
D R
IV
E
R O
D S
41" GUARD RAIL
41" GUARD RAIL
56" GUARD RAIL
56" GUARD RAIL
56" GUARD RAIL
S
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
SHEET ID
A
B
C
D
E
F
G
1 98765432
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
M-501
REF
M-501
REF
STATIONARY PLATFORM GRATING
STATIONARY PLATFORM SUPPORT BEAM
STAGE TWO CARRIAGE
EXTENDING PLATFORM
STAGE ONE CARRIAGE
EXTENDING PLATFORM
TOP OF STATIONARY PLATFORM GRATING
PLATFORM WALKING SURFACE SLIDES ON
1/4" DIAMOND PLATE EXTENDING
M-502
A1
M-502
A1
M-502
A1
M-502
A1
M-502
A1
M-511
A2
M-510
A2
M-510
A2
M-510
A2
M-511
A2
M-506
C7
M-509
A4
M-509
C4
M-509
C4
M-509
C4
M-509
A8
VOLUME 1
/2
/2
U P
D A
T E
D L
IG
H
T F
IX
T
U R
E H
O U
S
IN
G M
A T
E R
IA
L
N S
I D
L L
A W
A L
L A
D
IS
T R
IC
T
F
IL
E N
R E
P A
IR
P
IT
L
IT
T L
E G
O O
S E
L O
C K
A N
D D
A M
S N
A K
E R
IV
E
R O
R E
G O
N W
A S
H
IN
G T
O N
A N
D I
D A
H O
P O
W E
R H
O U
S E
G A
T E
R E
P A
IR
P
IT
U
P G
R A
D E
S
D
F
IL
A N
K
S E
L L
E R
S
K
S E
L L
E R
S
E-505
J E
F F
R E
Y L
Y O
N P
.E
L G
P -1
-6 -3
/2
L L
A W
A L
L A
W
A S
H
IN
G T
O N
N
R
D A
V E
W
E F
B
FINALDS: PD: AEC_pdf.pltcfg7:53:13 AM 1/5/2021
...\...\LG456129\...\LG456129E-505XXX.dgn
L
IG
H T
F
IX
T U
R E
D E
T A
IL
7,900 LUMEN INDUSTRIAL LIGHT FIXTURE DETAIL
B3
3,700 LUMEN INDUSTRIAL LIGHT FIXTURE DETAIL
B5
/1
/2
U P
D A
T E
D L
IG
H
T F
IX
T
U R
E D
E T
A
IL
S
S O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
SHEET ID
A
B
C
D
E
F
G
1 98765432
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
ALUMINUM OR A GOVERNMENT APPROVED MATERIAL.
STEEL THAT IS CHEMICALLY TREATED FOR RUST PREVENTION, COPPER FREE
HOUSING MATERIAL SHALL BE 0.032" MINIMUM THICKNESS DIE FORMED COLD ROLLED12.
THE LUMINAIRE SHALL NOT PERMANENTLY DISTORT WHEN LIFTED BY ONE CORNER.11.
PROVIDE INTERNAL PROVISIONS FOR GROUNDING
HOUSING WELDED OR SECURED BY SCREWS OR RIVETS INTO A SINGLE ASSEMBLY,10.
DIMENSIONS: APPROXIMATELY 50-55 INCHES IN LENGTH AND 6-7 INCHES IN WIDTH9.
90 MINUTE EMERGENCY BACK UP BATTERY WHERE SPECIFIED8.
FLUSH BACK MOUNTING7.
NEMA 4X ENCLOSURE6.
TOTAL HARMONIC DISTORTION: <15%5.
POWER FACTOR: >= 0.904.
VOLTAGE: 120 VAC3.
ELECTRICAL FREQUENCY" 50/60 HZ2.
LUMEN OUTPUT: APPROXIMATELY 7,900 1.
ALUMINUM OR A GOVERNMENT APPROVED MATERIAL.
STEEL THAT IS CHEMICALLY TREATED FOR RUST PREVENTION, COPPER FREE
HOUSING MATERIAL SHALL BE 0.032" MINIMUM THICKNESS DIE FORMED COLD ROLLED11.
THE LUMINAIRE SHALL NOT PERMANENTLY DISTORT WHEN LIFTED BY ONE CORNER.10.
PROVIDE INTERNAL PROVISIONS FOR GROUNDING
HOUSING WELDED OR SECURED BY SCREWS OR RIVETS INTO A SINGLE ASSEMBLY,9.
DIMENSIONS: APPROXIMATELY 20-25 INCHES IN LENGTH AND 6-7 INCHES IN WIDTH8.
FLUSH BACK MOUNTING7.
NEMA 4X ENCLOSURE6.
TOTAL HARMONIC DISTORTION: <15%5.
POWER FACTOR: >= 0.904.
VOLTAGE: 120 VAC3.
ELECTRICAL FREQUENCY" 50/60 HZ2.
LUMEN OUTPUT: APPROXIMATELY 3,700 1.
| LG456129M-508XXX |
| LG456129E-505XXX |
File details come from the government source that posted it. Updated .