A.01.30Amend-0001_Summary.pdf
PDF 50 KB Posted
- Solicitation number
- W912EF-15-R-0046
About this file
Amendment 0001 Summary
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A.01.30Amendment_0002_Summary.doc | DOC document | |
| A.07.24W912EF-15-R-0046Amendment0002.pdf | ||
| A.01.30TechnicalSpecAmendment2.pdf | ||
| A.01.30TechSpec_Amend-0001.pdf | ||
| A.07.24_W912EF-15-R-0046Amendment0001.pdf | ||
| A.01.30Plans_Amend-0001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Summary of changes for Amend -0001 Ice Harbor/Little Goose Spare Set Draft Tube Stoplogs
W912EF-15-R-0046
1. Revised the following Specifications (see revised specifications for details):
a. SECTION 01 11 01.00 28 SUPPLEMENTARY REQUIREMENT
• Added Paragraph 1.4 ESTIMATED EXISTING STOPLOG WEIGHTS.
• Renumbered Paragraphs.
b. SECTION 05 59 13.00 28 FABRICATION OF HYDRAULIC STEEL STRUCTURES
• Revised Paragraph 1.3.1 Qualification of Structural Steel Fabricator.
• Revised Paragraph 3.8 WEIGHT OF STOPLOGS
2. Revised the following Drawings (See bracketed areas):
a. Volume 1 SHEET G-501.
b. Volume 1 SHEET S-302.
3. Revised the following Clause ( Yellow highlighted revision number and date on the index below are for this Amendment 0001):
252.236-7001 CONTRACT DRAWINGS, MAPS, AND SPECIFICATIONS (AUG 2000)
(a) The Government will provide to the Contractor, without charge, one set of contract drawings and specifications, except publications incorporated into the technical provisions by reference, in electronic or paper media as chosen by the Contracting Officer.
(b) The Contractor shall--
(1) Check all drawings furnished immediately upon receipt;
(2) Compare all drawings and verify the figures before laying out the work;
(3) Promptly notify the Contracting Officer of any discrepancies;
(4) Be responsible for any errors that might have been avoided by complying with this paragraph (b); and
(5) Reproduce and print contract drawings and specifications as needed.
(c) In general--
(1) Large-scale drawings shall govern small-scale drawings; and
(2) The Contractor shall follow figures marked on drawings in preference to scale measurements.
(d) Omissions from the drawings or specifications or the misdescription of details of work that are manifestly necessary to carry out the intent of the drawings and specifications, or that are customarily performed, shall not relieve the Contractor from performing such omitted or misdescribed details of the work. The Contractor shall perform such details as if fully and correctly set forth and described in the drawings and specifications.
(e) The work shall conform to the specifications and the contract drawings identified on the following index of drawings:
Drawing Number
Sheet
Title
Revision
Date
ICE HARBOR LOCK AND DAM
VOL. 1 - SPARE SET DRAFT TUBE STOPLOGS
GENERAL
IHG-1-0-1/494 G-001 COVER SHEET AND LOCATION MAPS
IHG-1-0-1/495 G-002 INDEX TO DRAWINGS
IHG-1-0-1/496 G-501 STOPLOG TOLERANCES - AND KEY
SECTION A 11/2/15
STRUCTURAL
IHP-1-5-1/19 S-301 TOP STOPLOG SECTION - PLAN AND
ELEVATION
IHP-1-5-1/20 S-302 SECOND STOPLOG SECTION - PLAN
AND ELEVATION A 10/29/15
IHP-1-5-1/21 S-303 THIRD STOPLOG SECTION - PLAN
AND ELEVATION
IHP-1-5-1/22 S-304 BOTTOM STOPLOG - PLAN AND
ELEVATION
IHP-1-5-1/23 S-401 TOP, 2ND & 3RD STOPLOG
SECTIONS - END ELEVATIONS
IHP-1-5-1/24 S-402 TOP, 2ND & 3RD STOPLOGS -
SECTION B
IHP-1-5-1/25 S-403 TOP, 2ND & 3RD STOPLOGS -
SECTION C
IHP-1-5-1/26 S-404 TOP, 2ND & 3RD STOPLOGS -
SECTION D
IHP-1-5-1/27 S-405 BOTTOM STOPLOG - END
ELEVATION - AND SECTION
IHP-1-5-1/28 S-406 BOTTOM STOPLOG - SECTIONS -
AND SECTIONS
IHP-1-5-1/29 S-501 STOPLOG DETAILS
IHP-1-5-1/30 S-502 SEAL DETAILS 1
IHP-1-5-1/31 S-503 SEAL DETAILS 2
FOR INFORMATION ONLY
IHP-1-4-2/31 FIO-001
POWERHOUSE CONCRETE OUTLINE
- GENERATOR BAYS - DRAFT TUBE
BULKHEAD BLOCKOUTS
IHP-1-5-1/4 FIO-002
POWERHOUSE STRUCTURAL -
DRAFT TUBE BULKHEAD GUIDES -
DRAFT TUBE BULKHEAD
BLOCKOUTS
IHP-1-4-2/25 FIO-003 POWERHOUSE CONCRETE OUTLINE
- GENERATOR BAYS - TAILRACE
DECK PLAN & DETAILS
IHP-1-4-0/1 FIO-004
POWERHOUSE CONCRETE -
GENERAL PLAN AND - SECTION OF
GENERATOR BAY
IHP-1-5-2/22 FIO-005
POWERHOUSE - NEW BOTTOM
DRAFT TUBE BULKHEAD -
MISCELLANEOUS DETAILS
IHP-1-5-2/20 FIO-006 POWERHOUSE - McNARY DRAFT
TUBE BULKHEADS - ALTERATIONS
IHP-1-5-2/14 FIO-007
POWERHOUSE - DRAFT TUBE
BULKHEADS - TOP SECTION -
McNARY DAM
IHP-1-5-2/15 FIO-008
POWERHOUSE - DRAFT TUBE
BULKHEADS - INTERMEDIATE
SECTION - McNARY
IHP-1-5-2/16 FIO-009
BULKHEADS - BOTTOM SECTION -
McNARY DAM
IHP-1-5-2/16 FIO-010
POWERHOUSE - MECHANICAL -
DRAFT TUBE - BULKHEAD LIFTING
BEAM
Drawing
Sheet
Title
Revision
Date
LITTLE GOOSE LOCK AND DAM
VOL. 2 - SPARE SET DRAFT TUBE STOPLOGS
GENERAL
LGG-1-0-
1/367 G-001 COVER SHEET AND LOCATION MAPS
LGG-1-0-
1/368 G-002 INDEX TO DRAWINGS
LGG-1-0-
1/369 G-501 STOPLOG TOLERANCES - AND KEY
PLAN - SHEET TITLE LINE 3
STRUCTURAL
LGP-1-5-1/14 S-301 TOP STOPLOG SECTION - PLAN AND
ELEVATION
LGP-1-5-1/15 S-302 MIDDLE STOPLOG SECTION - PLAN
AND ELEVATION
LGP-1-5-1/16 S-303 BOTTOM STOPLOG SECTION - PLAN
AND ELEVATION
LGP-1-5-1/17 S-304 STOPLOG SECTIONS - END
ELEVATIONS
LGP-1-5-1/18 S-501 DETAILS 1
LGP-1-5-1/19 S-502 DETAILS 2
LGP-1-5-1/20 S-503 DETAILS 3
FOR INFORMATION ONLY
LGP-1-4-2/9 FIO-001
GENERATOR BAY CONCRETE
OUTLINE - BLOCKOUTS - DRAFT
TUBE BULKHEAD GUIDES
LGP-1-4-2/5 FIO-002
OUTLINE - DRAFT TUBE PLAN - BAYS
1, 2 & 3
LGP-1-4-2/6 FIO-003
OUTLINE - DRAFT TUBE PLAN - BAYS
4, 5 & 6
LGP-6-0-0/2 FIO-004
POWERHOUSE ARRANGEMENT -
GENERATOR BAY - TRANSVERSE
SECTION
LGP-1-4-2/48 FIO-005
POWERHOUSE - GENERATOR BAY
CONCRETE OUTLINE - DRAFT TUBE
CONCRETE PLUG
LGP-1-5-2/12 FIO-006 POWERHOUSE - DRAFT TUBE
BULKHEAD - TOP SECTION
LGP-1-5-2/14 FIO-007 POWERHOUSE - DRAFT TUBE
BULKHEAD - BOTTOM SECTION
LGP-1-3-2/1 FIO-008 POWERHOUSE - DRAFT TUBE
BULKHEAD & STOPLOG - LIFTING
BEAMS
701A FIO-009
POWERHOUSE - DRAFT TUBE
BULKHEAD - LIFTING BEAM
ASSEMBLY
701B FIO-010 POWERHOUSE - DRAFT TUBE
BULKHEAD - LIFTING BEAM DETAILS
182D FIO-011 POWERHOUSE - DRAFT TUBE
BULKHEAD - DOGGING BEAM DETAIL
183A FIO-012
BULKHEAD - RETAINER BARS AND
DETAILS
183B FIO-013 POWERHOUSE - DRAFT TUBE
BULKHEAD - RUBBER SEAL DETAILS
(End of drawing list)
File details come from the government source that posted it. Updated .