Amendment_0006__W912DW18B0003.pdf
PDF 570 KB Posted
- Solicitation number
- W912DW18B0003
About this file
Amendment 0006 - W912DW18B0003
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FBO_Bid_Abstract-_W912DW18B0003.XLS | XLS spreadsheet | |
| Amend_0007_W912DW18B0003.pdf | ||
| Amendment_0005_W912DW18B0003.pdf | ||
| Amendment_0004_W912DW18B0003.pdf | ||
| Amendment_0003_W912DW18B0003.pdf | ||
| Amend_0002_W912DW18B0003.pdf | ||
| Amendment_0001_W912DW18B0003.pdf | ||
| Sol_W912DW18B0003_9_Feb_2018.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this Amendment 0006 is to: 1) Clarify ProjNet question regarding mechanical blinds (E2-103);
2) Provide clarity on intent of the Fire Sprinklers along second f loor atrium (A3-302 and A3-510) See attached draw ing/plans; 3) Update Index of Draw ings NOTE: The Scheduled Bid Opening/Due date remains unchanged: Tuesday, April 3, 2018 at 2:00 PM, Pacif ic Time.
All other terms and conditions remain unchanged.
NOTICE: Bidders must acknow ledge receipt of this Amendment by number and date on the proposal.
1. CONTRACT ID CODE PAGE OF PAGES
1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 30-Mar-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912DW18B0003
X 9B. DATED (SEE ITEM 11)
09-Feb-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
30-Mar-2018
CODE
USA ENGINEER DISTRICT, SEATTLE
ATTN: CENWS-CT
4735 EAST MARGINAL WAY SOUTH, BLDG. 1202
SEATTLE WA 98134-2388
W912DW 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912DW18B0003
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
SUMMARY AMENDMENT 0005
The purpose of this Amendment is:
1. Revised 00 73 00-A Index of Drawings (remove/replace)
2. Clarified ProjNet question regarding mechanical blinds (E2-103)
3. Provided clarity on intent of the Fire Sprinklers along second floor atrium (A3-302 and A3-510)
(See Attached Sections and Drawings)
4. All other terms and conditions remain unchanged.
5. The Scheduled Bid Opening/Due date remains unchanged:
Tuesday, April 3, 2018 at 2:00 PM, Pacific Time.
6. NOTICE TO BIDDERS: Bidders must acknowledge receipt of this Amendment 0006 by number and date on proposal. Please mark outside of the envelope in which your bid is enclosed to show amendment received.
The following have been deleted:
W912DW18B0003
(End of Summary of Changes)
FY16 WAARNG Barracks & DFAC 12050 Yakima Training Center, WA W912DW18B0003
00 73 00-A - 1 R0006
ATTACHMENT 00 73 00-A
INDEX OF DRAWINGS
DRAWING RECORD NO. 24s/721-10-01, DATED: 24 October 2017
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
VOLUME 1 - SITE DRAWINGS
1 G0-001 COVER SHEET
2 G0-002 DRAWING INDEX 1
3 G0-003 DRAWING INDEX 2
4 G0-004 DRAWING INDEX 3
GENERAL
5 G1-001 VOLUME 1 - TITLE
6 G1-002 VOLUME 1 - DRAWING INDEX
GEOTECHNICAL
7 B-101 LOCATIONS FOR EXPLORATION
8 B-301 EXPLORATION LOGS 1
9 B-302 EXPLORATION LOGS 2
CIVIL
10 C-001 LEGEND, ABBREVIATIONS, & GENERAL NOTES
11 C-002 ACCESS & HAUL ROUTE
12 C-003 EXISTING SITE PLAN
13 CD101 DEMOLITION PLAN 1
14 CD102 DEMOLITION PLAN 2
15 CD103 DEMOLITION PLAN 3
16 CS101 GENERAL SITE PLAN
17 CS102 SITE PLAN 1
18 CS103 SITE PLAN 2
19 CS104 SITE PLAN 3
20 CS105 WATER DISTRIBUTION MAIN LOOP - BID OPTION
21 CP101 JOINT LAYOUT OVERALL PLAN
22 CP102 JOINT LAYOUT PLAN 1 - BARRACKS WEST ENTRANCE
23 CP103 JOINT LAYOUT PLAN 2 - BARRACKS EAST ENTRANCE
24 CP104 JOINT LAYOUT PLAN 3 - LOADING DOCK
25 CP105 JOINT LAYOUT PLAN 4 - DUMPSTER AREA
26 CP106 JOINT LAYOUT PLAN 5 - DFAC PATIO - BID OPTION
00 73 00-A - 2 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
27 CG101 OVER-EXCAVATION PLAN
28 CG102 GRADING PLAN 1 R0003 14 MAR 2018
29 CG103 GRADING PLAN 2 R0003 14 MAR 2018
30 CG104 GRADING PLAN 3 R0003 14 MAR 2018
31 CU101 UTILITY PLAN 1
32 CU102 UTILITY PLAN 2
33 CU103 STORMWATER PLAN 1
34 CU104 STORMWATER PLAN 2
35 CU105 STORMWATER PLAN 3
36 C-301 SANITARY SEWER PROFILES 1 - LINE SS-1
37 C-302 SANITARY SEWER PROFILES 2 - LINE SS-2
38 C-303 SANITARY SEWER PROFILES 3 - LINE SS-3
39 C-304 SANITARY SEWER PROFILES 4 - LINE SS-4
40 C-305 STORMWATER PROFILES 1 - LINE SD-1
41 C-306 STORMWATER PROFILES 2 - LINE SD-2
42 C-307 STORMWATER PROFILES 3 - LINE SD-2A
43 C-308 STORMWATER PROFILES 4 - LINE SD-2A & SD-2A1
44 C-309 STORMWATER PROFILES 5 - LINE SD-2B
45 C-310 STORMWATER PROFILES 6 - LINE SD-2B
46 C-311 STORMWATER PROFILES 7 - LINE SD-3
47 C-312 STORMWATER PROFILES 8 - LINE SD-3 & SD-3A
48 C-313 STORMWATER PROFILES 9 - LINE SD-4 & SD-5
49 C-314 STORMWATER PROFILES 10 - LINE SD-5A
50 C-501 DETAILS 1 - PAVING SECTIONS
51 C-502 DETAILS 2 - PAVEMENT JUNCTION DETAILS 1
52 C-503 DETAILS 3 - PAVEMENT JUNCTION DETAILS 2
53 C-504 DETAILS 4 - PAVEMENT JOINT DETAILS
54 C-505 DETAILS 5 - PATIO JOINT DETAILS
55 C-506 DETAILS 6 - SIDEWALK SECTIONS & JOINT DETAILS
56 C-507 DETAILS 7 - PAVEMENT & SLAB REINFORCEMENT DETAILS
57 C-508 DETAILS 8 - UTILITY 1
58 C-509 DETAILS 9 - UTILITY 2
59 C-510 DETAILS 10 - UTILITY 3
00 73 00-A - 3 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
60 C-511 DETAILS 11 - MISCELLANEOUS 1
61 C-512 DETAILS 12 - MISCELLANEOUS 2
62 C-513 DETAILS 13 - SIGNAGE DETAILS
63 C-514 DETAILS 14 - STORM DRAINAGE 1
64 C-515 DETAILS 15 - STORM DRAINAGE 2
LANDSCAPE
65 L-001 LEGEND, ABBREVIATIONS, & GENERAL NOTES
66 LS101 LANDSCAPE SITE PLAN 1
67 LS102 LANDSCAPE SITE PLAN 2
68 LS103 LANDSCAPE SITE PLAN 3
69 L-501 LANDSCAPE DETAILS 1
STRUCTURAL
70 S-101 DUMPSTER ENCLOSURE - FOUNDATION PLAN
71 S-102 DUMPSTER ENCLOSURE - FOUNDATION PLAN
ARCHITECTURAL
72 A-101 DUMPSTER ENCLOSURE - PLANS, ELEVATIONS & SECTIONS
73 A-102 DUMPSTER ENCLOSURE - PLANS, ELEVATIONS & SECTIONS
ELECTRICAL
74 E-001 LEGEND & ABBREVIATIONS
75 ED100 ELECTRICAL DEMOLITION PLAN
76 ES100 ELECTRICAL GENERAL SITE PLAN
77 ES101 ELECTRICAL SITE PLAN 1
78 ES102 ELECTRICAL SITE PLAN 2
79 E-501 ELECTRICAL EXTERIOR DETAILS 1
80 E-502 ELECTRICAL EXTERIOR DETAILS 2
81 E-503 ELECTRICAL EXTERIOR DETAILS 3
TELECOMMUNICATIONS
82 T-001 TELECOMMUNICATIONS LEGEND & ABBREVIATIONS
83 TD100 TELECOMMUNICATIONS DEMOLITION PLAN
84 TS100 TELECOMMUNICATIONS GENERAL SITE PLAN
85 T-501 TELECOMMUNICATIONS DETAILS 1
86 T-502 TELECOMMUNICATIONS DETAILS 2
00 73 00-A - 4 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
VOLUME 2 - DFAC DRAWINGS
GENERAL
87 G2-001 VOLUME 2 - TITLE
88 G2-002 VOLUME 2 - DRAWING INDEX
STRUCTURAL
89 S2-001 GENERAL STRUCTURAL NOTES, DESIGN LOADS, &
ABBREVIATIONS
90 S2-002 GENERAL STRUCTURAL NOTES
91 S2-003 GENERAL STRUCTURAL NOTES
92 S2-101 FOUNDATION PLAN
93 S2-102 SHEARWALL PLAN
94 S2-103 ROOF FRAMING PLAN
95 S2-301 FOUNDATION SECTIONS
96 S2-302 ROOF FRAMING SECTIONS
97 S2-303 FLAT ROOF FRAMING SECTIONS
98 S2-501 TYPICAL STRUCTURAL DETAILS
99 S2-502 TYPICAL STRUCTURAL DETAILS
100 S2-503 TYPICAL WOOD DETAILS
101 S2-504 TYPICAL CMU DETAILS
102 S2-601 WOOD NAILING SCHEDULE
103 S2-602 WIND & SNOW LOAD DIAGRAM
ARCHITECTURAL
104 A2-001 ABBREVIATIONS, SYMBOLS, & GENERAL NOTES
105 A2-002 LIFE SAFETY SUMMARY R0005 22 MAR 2018
106 A2-003 LIFE SAFETY PLAN
107 A2-004 AIR BARRIER PLAN
108 A2-005 AIR BARRIER SECTION/DETAILS
109 A2-006 AIR BARRIER SECTION/DETAILS
110 A2-101 FLOOR PLAN
111 A2-102 REFLECTED CEILING PLAN
112 A2-103 CLEARSTORY & ROOF PLAN
113 A2-201 ELEVATIONS (NORTH & EAST)
114 A2-202 ELEVATIONS (SOUTH & WEST)
115 A2-203 INTERIOR RESTROOM ELEVATIONS
00 73 00-A - 5 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
116 A2-204 INTERIOR ELEVATIONS
117 A2-205 INTERIOR ELEVATIONS
118 A2-301 BUILDING SECTIONS
119 A2-302 BUILDING SECTIONS R0006 30 MAR 2018
120 A2-303 BUILDING SECTIONS
121 A2-310 WALL SECTIONS 1
122 A2-311 WALL SECTIONS 2
123 A2-401 ENLARGED PLANS - RESTROOMS & SCULLERY
124 A2-402 ENLARGED PLAN - RESTROOM
125 A2-403 ENLARGED PLAN - KITCHEN
126 A2-501 FOUNDATION & WALL DETAILS
127 A2-502 ROOF & WALL DETAILS
128 A2-503 DINING HALL ROOF & WALL DETAILS
129 A2-504 ROOF & WALL DETAILS
130 A2-505 ROOF & WALL DETAILS
131 A2-506 EXTERIOR DOOR DETAILS
132 A2-507 INTERIOR DOOR DETAILS
133 A2-508 CEILING & SKYLIGHT DETAILS
134 A2-509 INTERIOR BATHROOM DETAILS
135 A2-510 INTERIOR DETAILS
136 A2-511 CASEWORK
137 A2-601 WALL TYPES
138 A2-602 ROOM FINISH SCHEDULE
139 A2-603 DOOR SCHEDULE
140 A2-604 WINDOW SCHEDULE & EXTERIOR FINISH SCHEDULE R0005 22 MAR 2018
141 A2-605 SIGNAGE SCHEDULE & SIGNAGE PLAN
142 A2-606 SIGNAGE TYPES
143 A2-701 FINISH FLOOR PLAN & FFE FLOOR PLAN
144 A2-702 ENLARGED PLANS - KITCHEN
145 A2-703 KITCHEN EQUIPMENT SCHEDULE
146 A2-704 INTERIOR KITCHEN ELEVATIONS
147 A2-705 KITCHEN EQUIPMENT DETAILS
00 73 00-A - 6 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
PLUMBING
148 P2-101 KITCHEN PLUMBING PLAN
ELECTRICAL
149 E2-001 LEGEND & ABBREVIATIONS
150 E2-101 FLOOR LIGHTING PLAN
151 E2-102 FLOOR POWER PLAN
152 E2-103 ROOF POWER PLAN R0006 28 MAR 2018
153 E2-104 EQUIPMENT PLAN
154 E2-501 LIGHTING DETAILS 1
155 E2-502 LIGHTING DETAILS 2
156 E2-503 LIGHTING DETAILS 3
157 E2-601 ONE-LINE POWER DIAGRAM
TELECOMMUNICATIONS
158 T2-001 LEGEND & ABBREVIATIONS
159 T2-101 FLOOR COMMUNICATION PLAN
VOLUME 3 - BARRACKS DRAWINGS
GENERAL
160 G3-001 VOLUME 3 - TITLE
161 G3-002 VOLUME 3 - DRAWING INDEX
STRUCTURAL
162 S3-001 GENERAL STRUCTURAL NOTES, DESIGN LOADS &
ABBREVIATIONS
163 S3-002 GENERAL STRUCTURAL NOTES, 2 OF 3
164 S3-003 GENERAL STRUCTURAL NOTES, 3 OF 3
165 S3-100 OVERALL FOUNDATION PLAN
166 S3-101 PARTIAL FOUNDATION PLAN SOUTH
167 S3-102 PARTIAL FOUNDATION PLAN NORTH
168 S3-103 PARTIAL SECOND FLOOR FRAMING PLAN SOUTH
169 S3-104 PARTIAL SECOND FLOOR FRAMING PLAN NORTH
170 S3-105 PARTIAL THIRD FLOOR FRAMING PLAN SOUTH
171 S3-106 PARTIAL THIRD FLOOR FRAMING PLAN NORTH
172 S3-107 PARTIAL ROOF FRAMING PLAN SOUTH
00 73 00-A - 7 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
173 S3-108 PARTIAL ROOF FRAMING PLAN NORTH
174 S3-109 ENLARGED SECOND FLOOR CORE PLAN
175 S3-110 ENLARGED THRID FLOOR CORE PLAN
176 S3-111 ENLARGED ROOF CORE PLAN
177 S3-112 ENLARGED UPPER ROOF PLANS
178 S3-113 SHEARWALL PLAN SOUTH END
179 S3-114 SHEARWALL PLAN NORTH END
180 S3-201 METAL SCREEN ELEVATION, SHEET 1 OF 2
181 S3-202 METAL SCREEN ELEVATION, SHEET 2 OF 2
182 S3-301 ELEVATOR PIT SECTIONS
183 S3-302 ROOF FRAMING SECTIONS
184 S3-303 TRUSS FRAMING SECTIONS
185 S3-304 METAL PANEL & METAL SCREEN SECTIONS AND DETAILS
186 S3-401 ENLARGED END STAIR PLANS & SECTIONS
187 S3-402 ENLARGED CENTER STAIR PLAN & SECTION
188 S3-403 ENLARGED CANOPY FRAMING PLAN
189 S3-501 TYPICAL STRUCTURAL DETAILS 1
190 S3-502 TYPICAL STRUCTURAL DETAILS 2
191 S3-503 SHEARWALL DETAILS
192 S3-504 TRELLIS PLAN VIEW
193 S3-505 TRELLIS ELEVATIONS 1
194 S3-506 TRELLIS ELEVATIONS 2
195 S3-507 TRELLIS DETAILS
196 S3-511 FOUNDATION DETAILS
197 S3-521 FLOOR FRAMING DETAILS
198 S3-522 FLOOR FRAMING DETAILS 2
199 S3-523 FLOOR FRAMING DETAILS 3
200 S3-531 ROOF FRAMING DETAILS
201 S3-601 WALL SCHEDULES
202 S3-602 WOOD NAILING SCHEDULE
203 S3-603 WIND LOAD DIAGRAMS
204 S3-604 AT/FP FRAMING & DETAILS
205 S3-605 BEAM SHEAR TAB SCHEDULE
00 73 00-A - 8 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
ARCHITECTURAL
206 A3-001 ABBREVATIONS, SYMBOLS, & GENERAL NOTES
207 A3-002 LIFE SAFETY CODE ANALYSIS
208 A3-003 1ST, 2ND, & 3RD FLOOR LIFE SAFETY PLAN
209 A3-004 AIR BARRIER TYPICAL COMPONENTS
210 A3-101 OVERALL FIRST FLOOR PLAN
211 A3-102 OVERALL SECOND & THIRD FLOOR PLANS
212 A3-103 OVERALL ROOF PLAN
213 A3-104 FIRST FLOOR PLAN - NORTH
214 A3-105 FIRST FLOOR PLAN - SOUTH
215 A3-106 SECOND FLOOR PLAN - NORTH
216 A3-107 SECOND FLOOR PLAN - SOUTH
217 A3-108 THIRD FLOOR PLAN - NORTH
218 A3-109 THIRD FLOOR PLAN - SOUTH
219 A3-110 ROOF PLAN - NORTH
220 A3-111 ROOF PLAN - SOUTH
221 A3-112 ENLARGED CORE PLAN - FIRST FLOOR
222 A3-113 ENLARGED CORE PLAN - SECOND FLOOR
223 A3-114 ENLARGED CORE PLAN - THIRD FLOOR
224 A3-115 OVERALL REFLECTED CEILING PLANS - FIRST & SECOND
FLOORS
225 A3-116 OVERALL REFLECTED CEILING PLANS - THIRD FLOOR
226 A3-117 ENLARGED CORE RCP - FIRST FLOOR
227 A3-118 ENLARGED CORE RCP - SECOND FLOOR
228 A3-119 ENLARGED CORE RCP - THIRD FLOOR
229 A3-201 ELEVATIONS - EAST & SOUTHEAST
230 A3-202 ELEVATIONS - WEST & NORTHWEST
231 A3-203 ELEVATIONS - NORTH & SOUTHWEST
232 A3-210 ENLARGED ELEVATIONS - SOUTHEAST
233 A3-211 ENLARGED ELEVATIONS - EAST
234 A3-212 ENLARGED ELEVATIONS - WEST & NORTHWEST
235 A3-301 BUILDING SECTIONS I
236 A3-302 BUILDING SECTIONS II
00 73 00-A - 9 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
237 A3-303 WALL SECTIONS I
238 A3-304 WALL SECTIONS II
239 A3-401 ENLARGED 1+1 UNIT PLANS - NORTH
240 A3-402 ENLARGED 1+1 UNIT PLANS - SOUTH
241 A3-403 ENLARGED FIRST FLOOR RESTROOM & INTERIOR
ELEVATIONS
242 A3-404 ENLARGED STAIR #1 FLOOR PLANS
243 A3-405 ENLARGED STAIR #1 SECTION
244 A3-406 ENLARGED STAIR #2 FLOOR PLANS
245 A3-407 ENLARGED STAIR #2 SECTION
246 A3-408 ENLARGED STAIR #3 FLOOR PLANS
247 A3-409 ENLARGED STAIR #3 SECTION
248 A3-410 ENLARGED ELEVATOR PLANS & SECTION
249 A3-501 EXTERIOR DETAILS
250 A3-502 METAL ROOF DETAILS I
251 A3-503 METAL ROOF DETAILS II
252 A3-504 LOW SLOPE ROOF DETAILS
253 A3-505 CANOPY & PATIO DETAILS
254 A3-506 WINDOW DETAILS I
255 A3-507 WINDOW & DOOR DETAILS I
256 A3-508 WINDOW & DOOR DETAILS II
257 A3-509 CURTAIN WALL DETAILS
258 A3-510 INTERIOR DETAILS R0006 30 MAR 2018
259 A3-511 CASEWORK DETAILS
260 A3-512 CEILING DETAILS
261 A3-513 ELEVATOR DETAILS
262 A3-514 INTERIOR STAIR DETAILS
263 A3-515 LANDSCAPE MONUMENT
264 A3-601 WALL TYPES
265 A3-602 DOOR, WINDOW, & FINISH SCHEDULE R0003 14 MAR 2018
266 A3-701 EXPANSION PLAN
267 A3-801 ISOMETRIC VIEWS - NORTHWEST & SOUTHEAST
INTERIORS
268 I3-001 ABBREVIATIONS & GENERAL NOTES
00 73 00-A - 10 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
269 I3-101 OVERAL FLOOR FINISH PLANS
270 I3-102 FLOOR FINISH PLAN - TYPICAL UNIT
271 I3-103 FLOOR FINISH PLANS - FIRST FLOOR CORE
272 I3-104 FLOOR FINISH PLANS - SECOND & THIRD FLOOR CORE
273 I3-105 FLOOR FINISH PLANS - FIRST FLOOR STAIRS
274 I3-106 FLOOR FINISH PLANS - SECOND & THIRD FLOOR STAIRS
275 I3-107 SIGNAGE PLAN - TYPICAL UNIT
276 I3-108 SIGNAGE PLAN - FIRST FLOOR CORE
277 I3-109 SIGNAGE PLAN - SECOND & THIRD FLOOR CORE
278 I3-110 SIGNAGE PLANS - FIRST FLOOR STAIRS
279 I3-111 SIGNAGE PLANS - SECOND & THIRD FLOOR STAIRS
280 I3-112 OVERALL FURNITURE PLANS
281 I3-113 FURNITURE PLAN - TYPICAL UNIT
282 I3-114 FURNITURE PLAN - FIRST FLOOR CORE
283 I3-115 FURNITURE PLANS - SECOND & THIRD FLOOR CORE
284 I3-601 INTERIOR FINISH SCHEDULE
285 I3-602 SIGNAGE SCHEDULE
MECHANICAL
286 M3-101 TYPICAL 1+1 UNIT MECHANICAL PLANS R0004 21 MAR 2018
ELECTRICAL
287 E3-001 LEGEND & ABBREVIATIONS
288 E3-101 FIRST FLOOR LIGHTING PLAN
289 E3-102 SECOND & THIRD FLOOR LIGHTING PLAN
290 E3-103 FIRST FLOOR POWER PLAN
291 E3-104 SECOND & THIRD FLOOR POWER PLAN
292 E3-105 ATTIC POWER PLAN
293 E3-401 TYPICAL 1+1 UNIT LIGHTING & POWER PLANS
294 E3-402 FIRST FLOOR CORE LIGHTING PLAN
295 E3-403 SECOND FLOOR CORE LIGHTING PLAN
296 E3-404 THIRD FLOOR CORE LIGHTING PLAN
297 E3-405 FIRST FLOOR CORE POWER PLAN
298 E3-406 SECOND FLOOR CORE POWER PLAN
299 E3-407 THIRD FLOOR CORE POWER PLAN
00 73 00-A - 11 R0006
PAGE# SHEET# SHEET TITLE
REVISION
NUMBER DATE
300 E3-408 ENLARGED STAIRS PLAN
301 E3-409 ENLARGED ELEVATOR PIT
302 E3-501 LIGHTING DETAILS 1
303 E3-502 LIGHTING DETAILS 2
304 E3-503 LIGHTING DETAILS 3
305 E3-601 ONE-LINE DIAGRAM
TELECOMMUNICATIONS
306 T3-001 TELECOMMUNICATIONS LEGEND & ABBREVIATIONS
307 T3-101 FIRST FLOOR TELECOMMUNICATIONS PLAN
308 T3-102 SECOND AND THIRD FLOOR TELECOMMUNICATIONS PLAN
309 T3-401 TYPICAL 1+1 UNIT TELECOMMUNICATIONS PLAN
310 T3-402 FIRST FLOOR CORE TELECOMMUNICATIONS PLAN
311 T3-403 SECOND AND THIRD FLOOR CORE TELECOMMUNICATIONS
PLAN
T.O. 1ST FL. SLAB
0"
T.O. 2ND FL. SLAB
12'-0"
T.O. 3RD FL. SLAB
24'-0"
T.O. PARAPET
36'-8"
T.O. ROOF
45'-9"
D C B A
WAITING AREA
VEST.
STUDY
LOUNGE/
STUDY ROOM
STUDY
LOUNGE/
STUDY ROOM
CORRIDOR
CORRIDOR
CORRIDOR
2" / 12"
2" / 12"
1E
6B
6B
A3-510
A3-509
OPP
28' -6
A3-504 3
A3-503
8 5
A3-503
PROVIDE SPRINKLERS AS
REQUIRED ALONG SECOND
FLOOR ATRIUM GLAZING TO
MEET UL FIRE RESISTANCE
RATING OF MFR'S GLAZING
ASSEMBLY.
T.O. 1ST FL. SLAB
0"
T.O. 2ND FL. SLAB
12'-0"
T.O. 3RD FL. SLAB
24'-0"
T.O. PARAPET
36'-8"
T.O. ROOF
45'-9"
41 2 3 9 10
11 2 A3-301
2'-0" RAKE TYP.
T.O. PLATE
34'-11"
2'-0"
STAIR #1
BEDROOM
201A
BEDROOM
201B
BEDROOM
301B
BEDROOM
301A
BEDROOM
101A
BEDROOM
101B
MECH. ROOM
BEDROOM
207A
BEDROOM
307A
BEDROOM
307B
BEDROOM
207B
MECH. RM.
MECH. RM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
STAIR #2
DIRTY LINEN/
JANITOR
CLEAN LINEN
323A
DIRTY LINEN/
JANITOR
CLEAN LINEN
223A
CQ DESK
ENTRY
VESTIBULE
CQ OFFICE
2" / 12"
1B
1B
2C
4C
4A
4A
4B
6B
4B1B 6A
4A
4A
1B
A3-504
A3-303
6B
4B
6B
6B
4B
A3-502
SIM
A3-502
SIM
A3-503
OPP, SIM
SEE DETAIL
7/A3-503
SEE DETAIL
5/A3-504
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
SI
ZE
FI
LE
N
AM
E:
D
AT
E :
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
FI
LE
N U
M
BE
R
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
1 2 3 4 5
D
C
B
A
FY
P N
W
AA
R
N G
Seattle District
SE
AT
TL
E
DI
ST
RI
CT
SE
AT
TL
E, W
AS
HI
NG
TO
N s/
7 2 1-
-0
O
C
TO
BE
R
VO
LU
M
E 3:
P N
B
AR
R
AC
KS
YA
KI
M
A
TR
AI
N
IN
G
C
EN
TE
R
, W
AS
H
IN
G
TO
N
K.
N
. B R
O W
N
SHEET
IDENTIFICATION
SHEET OF 151
W
2 D W
-1 8-
B -
3/
/2
1:
:4
PM
C :\U se rs
\ G 3E
C D
LN
M
\ D oc um en ts \P
N
0 0
_B
AR
K_ Ar ch ite ct ur e_ C
EN
T R
AL
_ r
_ G 3E
C D
LN
M
.rv t
3/
/2
1:
:4
PM
BU
SH
BU
SH
BU
IL
DI
N G
S
EC
TI
O
N S
II
N
EV
IT
T
A3-302
3/16" = 1'-0"A3-302
1 SECTION THROUGH WAITING ROOM
3/16" = 1'-0"A3-302
2 SECTION THROUGH UNITS AND ENTRY 8'8'
SCALE: 3/16"=1'-0"
0"4' 2'6'
SHEET KEYNOTES
KEY
1 SOUND ATTENUATION FIRE BLANKET INSULATION
IN CEILING, THIRD FLOOR ONLY
2 CONTINUOUS GLAZED 1-HR FIRE BARRIER
ASSEMBLY WITH WINDOW SPRINKLERS AND
STANDARD EPDM GASKET SEALED INTERMEDIATE
BUTT JOINTS. TRANSLUCENT WASHINGTON ARMY
NATIONAL GUARD LOGO ON GLASS. VERIFY
GRAPHICS WITH WAARNG PRIOR TO
PROCUREMENT.
3 SEISMIC JOINT AT EDGE OF MEMBRANE ROOF
4 SEISMIC JOINT FOLLOWS SLOPE OF SSMR
5 PROPOSED LOCATION FOR VERTICAL 6" PIPE WITH
METAL NEGATIVE PRESSURE WIND TURBINE AT
ROOF PER ENVIRONMENTAL SPECIFICATION;
EXTEND PIPE 2'-0" ABOVE ROOF LINE.
CONTRACTOR TO VERIFY LOCATION &
COORDINATION WITH MECHANICAL, PLUMBING &
ELECTRICAL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B R
_C
LA
R
IF
Y
SP
R
IN
KL
ER
S
AT
N
D F
LR
A
TR
IU
M F
IR
E
R
AT
ED
G
LA
ZI
N G
A
SS
EM
BL
Y
M
AR
LN
M
B
R0006
WIFI CLOSET
WALL PER SCHEDULE
DOUBLE STUDS, TOP
AND BOTTOM
18" X 24" PRE-
FABRICATED
LOCKING METAL
ACCESS PANEL,
PAINT TO MATCH
ADJACENT WALLS
3'-6" A.F.F.
B.O. PANEL
NOMINAL 2x4 "TOE-BOARD"
ON TOP OF PLYWD DECK,
ALL AROUND
1/2" PLYWOOD DECK
ON 2X4 JOISTS,
PROVIDE BLOCKING
BETWEEN JOISTS
WOOD 2X4 LEDGER,
ALL AROUND
NOTE:
SEE ELECTRICAL AND
TELECOMM FOR POWER
AND DATA WITHIN
CLOSET
SOUND ATTENUATION
INSULATION
CORRIDOR
EX
H
AU
ST
L O
C
AT
IO
N
S
PE
R M
FR
DOUBLE STACK
COMMERCIAL GAS
DRYERS
(N.I.C.)
1'-4"
METAL BRANCH DUCT FROM
COMMERCIAL DOUBLE STACK
DRYER, MATERIAL AND DIAMETER
PER DRYER MFR.
METAL TRUNK DUCT LEADS TO
DIRECT OUTSIDE VENT LOUVER ON
WEST WALL OF LAUNDRY ROOM.
PROVIDE DUCT WITH OFFSET TO
CLEAR SEISMIC JOINT. PROVIDE
LINT TRAP AND DUCT CLEANOUT
ACCESS PANEL ON EACH FLOOR
NEAR END OF LEVEL DUCT RUN.
SIZE PER MANUFACTURER'S
RECOMMENDATION FOR NUMBER
OF DRYERS EXHAUSTING
THROUGH DUCT.
MFR
PER
BLOCKOUT HOLES FOR EXHAUST
DUCTS
PLYWOOD ON INTERIOR OF STUD
CAVITY WALL AT SEISMIC
SEPARATION, SEE STRUCTURAL
TRIM RUBBER BASE AND SEAL AT
EXHAUST BLOCK OUTS
SOUND ATTENUATION BATTS IN
STUD WALLS, SEALL ALL
PENETRATIONS TO ACHIEVE MIN.
STC-50, REFERENCE GA FILE#
WP 3370 & 3812 AS SIMILAR
1 HR FIRE RATED WALL PER
SCHEDULE
FIELD VERIFY DEPTH OF DRYERS AND ADJUST SOFFIT DEPTH TO MATCH
2'-8"
2X4 WD STUD FRAMED SOFFIT
FINISHED WITH GWB
7' -4
AL
IG
N
T.O. 2ND FL. SLAB
12'-0"
C
GWB EDGE BEAD,
TYPICAL
5/8" GWB, PAINT PT-1
5/8" GWB CEILING,
PAINT PT-1
NOMINAL 2x4 LUMBER
ENGINEERED WD GIRDER,
SEE STRUCTURAL
GWB EDGE BEAD
AND SEALANT
PLYWOOD DECK TOPPED
WITH SELF LEVELING
GYPSUM CONCRETE
UNDERLAYMENT, SEE
STRUCTURES
INTERIOR NON-COMBUSTIBLE
FIRE RATED CURTAIN WALL
ASSEMBLY, ANODIZE CLEAR
NOMINAL 2x6
LUMBER SOFFIT
NOMINAL 2x6 WOOD
JOISTS HUNG FROM
GIRDER, SEE STRUCTURAL
8'-8"
B.O. SOFFIT
CORRIDOR
WAITING AREA
CORRIDOR
20'-6"
T.O. CURTAIN WALL
6" 8'
-6
FIRE RATED TRANSPARENT TEMPERED
GLAZING ASSEMBLY, SEE CURTAIN WALL
ELEVATIONS 4/A3-403
SYSTEM HAS NO VERTICAL
MULLIONS, SEAL ALL VERTICAL BUTT
JOINTS WITH STRUCTURAL
STANDARD EPDM RUBBER GASKET
SEAL, SEE DETAIL 9/A3-510
WOOD HEADER
GWB EDGE BEAD
AND SEALANT
SEALANT BETWEEN GWB AND
CURTAIN WALL FRAME
PLYWOOD
SHEATHING ON
2X6 STUD
WALL, SEE
STRUCTURAL
4"
5/8" GYPSUM BOARD,
BOTH SIDES
2X4 WOOD
STUDS @ 16"
O.C. EXTEND TO
STRUCTURE
PROVIDE
SPRINKLERS AS
REQUIRED ALONG
SECOND FLOOR
ATRIUM GLAZING TO
MEET UL FIRE
RESISTANCE RATING
OF MFR'S GLAZING
ASSEMBLY, BOTH
SIDES.
FOR SPRINKLERS
AS REQD
FOR SPRINKLERS
AS REQD
HORIZONTAL
2X4 WOOD
STUDS @ 16"
O.C., BOTH
SIDES
4" 4"
2"
3"
3"
WALL PER SCHEDULE
5/8" GYPSUM WALL BOARD,
PAINT PER INTERIORS
8"x3/4" DIA. EYE-BOLT
GROUTED INTO CONCRETE
SLAB
THICKENED
CONCRETE SLAB,
SEE STRUCTURAL
CL
6"6"
SCALE: 3"=1'-0"
0"4" 2"
1'1'
SCALE: 1 1/2"=1'-0"
0"6" 3"9"
6" 1' 2'1'
SCALE: 1"=1'-0"
0"
6" STUD
TO STUD
PRE-MANUFACTURED CONTINUOUS EXTRUDED
FLEXIBLE GASKET IN ALUMINUM FRAME, COLOR TO
MATCH ADJACENT WALLS
FASTEN TO STUDS PER MFR
RECOMMENDATIONS
MOUNT JOINT COVER FLUSH WITH
GYPSUM WALLBOARD
WALL PER SCHEDULE
G L
1 HR FIRE RATED GASKET
GL
6" STUD
TO STUD
WOOD JOISTS SUPPORTING
PLYWOOD DECK, SEE
STRUCTURAL
PRE-MANUFACTURED CONTINUOUS EXTRUDED
SEISMIC JOINT COVER PLATE, COLOR TO
MATCH FLOOR FINISH
FASTEN TO PLYWOOD DECK PER MFR
RECOMMENDATIONS
MOUNT JOINT COVER FLUSH WITH
FLOOR FINISH
FIRE BARRIER AS REQUIRED
FLOOR FINISH PER INTERIORS
FINISHED WOOD WINDOW SILL,
FACTORY PAINTED
WALL PER SCHEDULE
STEEL SHELF ANGLE,
SEE STRUCT.
THRU-WALL FLASHING
AND WEEP HOLES
SILL PAN FLASHING. SET IN
CONT. BEAD OF SEALANT
EXTERIOR PATIO
PER STRUCT. & CIVIL,
SLOPE AWAY FROM
BUILDING
WINDOW PER SCHEDULE
2X6 PRESERVATIVE TREATED WOOD
STUDS @ 24" O.C. FOR WALLS WITH
WASHER CONNECTIONS, WATER
SUPPLY AND WASTE
THRU-WALL FLASHING
AND WEEP HOLES
2X6 PRESERVATIVE
TREATED WOOD SILL PLATE
GALVANIZED METAL
CLOSURE PLATE
BACKER ROD AND SEALANT
WASHER IS N.I.C.
SHOWN FOR
REFERENCE ONLY
4'-0"
T.O. CMU
ADJ. MASONRY TIE
PROVIDE WATER RESISTANT
GWB AT LAUNDRY ROOM WALLS
C
TO STUD
6" STUD
PRE-MANUFACTURER CONTINUOUS
EXTRUDED FLEXIBLE GASKET IN
ALUMUNUM FRAME, COLOR TO MATCH
ADJACENT WALLS
1 HR FIRE RATED GASKET
WALL PER SCHEDULE
INTERIOR NON-COMBUSTIBLE
CURTAIN WALL ASSEMBLY,
ANODIZE CLEAR
SEALANT ALL AROUND TO
MEET 1-HR FIRE BARRIER
C 135°
MITERED GLASS AT
ANGLED BUTT JOINT
STRUCTURAL STANDARD EPDM RUBBER GASKET
SEAL AT VERTICAL BUTT JOINTS, TYPICAL
G
WALL PER SCHEDULE
INTERIOR NON-COMBUSTIBLE
CURTAIN WALL ASSEMBLY,
ANODIZE CLEAR
SEALANT ALL AROUND TO MEET
AS 1-HR FIRE RATED BARRIER
DRYWALL "J" BEAD AT
EDGE OF GWB
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
SI
ZE
FI
LE
N
AM
E:
D
AT
E :
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
FI
LE
N U
M
BE
R
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
1 2 3 4 5
D
C
B
A
FY
P N
W
AA
R
N G
Seattle District
SE
AT
TL
E
DI
ST
RI
CT
SE
AT
TL
E, W
AS
HI
NG
TO
N s/
7 2 1-
-0
O
C
TO
BE
R
VO
LU
M
E 3:
P N
B
AR
R
AC
KS
YA
KI
M
A
TR
AI
N
IN
G
C
EN
TE
R
, W
AS
H
IN
G
TO
N
K.
N
. B R
O W
N
SHEET
IDENTIFICATION
SHEET OF 151
W
2 D W
-1 8-
B -
3/
/2
2:
:5
PM
C :\U se rs
\ G 3E
C D
LN
M
\ D oc um en ts \P
N
0 0
_B
AR
K_ Ar ch ite ct ur e_ C
EN
T R
AL
_ r
_ G 3E
C D
LN
M
.rv t
3/
/2
2:
:5
PM
BU
SH
BU
SH
I N
TE
RI
O
R
DE
TA
IL
S N
EV
IT
T
A3-510
1 1/2" = 1'-0"A3-510
4 WIFI CLOSET
1" = 1'-0"A3-510
5 DRYER CHASE
3" = 1'-0"A3-510
1 LOBBY 1-HR FIRE BARRIER
3" = 1'-0"A3-510
3 SAFE ANCHOR
1 1/2" = 1'-0"A3-510
6 SEISMIC JOINT IN WALL
1 1/2" = 1'-0"A3-510
7 SEISMIC JOINT IN FLOOR
1 1/2" = 1'-0"A3-510
2 PONY WALL @ LAUNDRY
3" = 1'-0"A3-510
8 1 HOUR FIRE RATED JAMB AT SEISMIC JOINT
12" = 1'-0"A3-510
9 LOBBY 1-HR FIRE BARRIER BUTT JOINTS
3" = 1'-0"A3-510
10 LOBBY 1-HR FIRE BARRIER JAMB
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B R
_C
LA
R
IF
Y
SP
R
IN
KL
ER
S
AT
N
D F
LR
A
TR
IU
M F
IR
E
R
AT
ED
G
LA
ZI
N G
A
SS
EM
BL
Y
M
AR
LN
M
R0006
File details come from the government source that posted it.