2023 S_T J153646-1 Std_Tal_L4 Final Report_Part9.pdf

PDF 2 MB Posted

Attached to
Maintenance Dredging of Newark Bay, New Jersey, Federal Navigation Project
Solicitation number
W912DS24B0009
Issued by

About this file

This document contains raw data from a general chemistry analysis report for Job ID 180-153646-1. The report includes results for percent solids, HEM (Oil & Grease), TPH (SGT-HEM), and pH testing performed on various lab samples. The report contains method details, sample information, and test results.

The related federal contract opportunity is for Maintenance Dredging of Newark Bay, New Jersey, Federal Navigation Project, solicitation number W912DS24B0009. This is an Invitation for Bid issued by the U.S. Army Corps of Engineers Engineering District New York for maintenance dredging services. No other details about the contract requirements, response dates, set asides, or pricing terms are provided in the given materials.

View the file

Other files

File Type Posted
Bid Abstract W912DS24B0009.pdf PDF
Bid Abstract W912DS24B0009.pdf PDF
Amendment 2 W912DS24B0009.pdf PDF
W912DS24B0009 P00001.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part5.pdf PDF
2023 S_T 180-153912-2_BattelleCorp.xls XLS spreadsheet
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part2.pdf PDF
2023 ST_NB-Main_Port Chan(43-012)Final Report_Part2.pdf PDF
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part6.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part1.pdf PDF
2023 S_T DO005 Newark Bay Cover Letter.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part6.pdf PDF
2023 S_T J153256-2 Std_Tal_L4 Final Report.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part3.pdf PDF
2023 S_T 180-153718-1_BattelleCorp.xls XLS spreadsheet
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part5.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part6.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part4.pdf PDF
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part8.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part3.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part9.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part7.pdf PDF
2023 ST_NB-Main_Port Chan(43-012)Final Report_Part3.pdf PDF
2023 S_T 180-153256-1_BattelleCorp.xls XLS spreadsheet
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part4.pdf PDF
2023 S_T J153718-2 Std_Tal_L4 Final Report.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part2.pdf PDF
2023 ST FINAL-Newark Upland-DO005-w_cond format_Values.xlsx XLSX spreadsheet
2023 S_T 180-153718-2_BattelleCorp.xls XLS spreadsheet
2023 S_T 180-153646-2_BattelleCorp.xls XLS spreadsheet
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part8.pdf PDF
2023 S_T J153912-2 Std_Tal_L4 Final Report_Part1.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part2.pdf PDF
2023 ST_NB-Main Port Chan(43-012)Final Report_Part1.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part1.pdf PDF
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part7.pdf PDF
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part1.pdf PDF
2023 S_T J153646-1 Std_Tal_L4 Final Report_Part3.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part1.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part4.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part6.pdf PDF
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part8.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part7.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part5.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part2.pdf PDF
2023 S_T J153256-1 Std_Tal_L4 Final Report_Part7.pdf PDF
2023 S_T J153912-1 Std_Tal_L4 Final Report_Part3.pdf PDF
2023 S_T 180-153646-1_BattelleCorp.xls XLS spreadsheet
2023 S_T J153718-1 Std_Tal_L4 Final Report_Part5.pdf PDF
2023 S_T J153646-2 Std_Tal_L4 Final Report_Part1.pdf PDF
Show 40 more

Latest 50 of 119 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P ag e o f 9

P ag e o f 9

General Chemistry Raw Data Report Job ID: 180-153646-1

Batch: 429599 Analyst Initials: ELS Instrument: No EquipmentMethod: 2540G

Lab Sample ID: 180-153646-C-5 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

39.6021699819168None %

Dilution

Lab Sample ID: 180-153646-C-1 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

40.4362416107383None %

Dilution

Lab Sample ID: 180-153646-C-2 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

44.269340974212None %

Dilution

Lab Sample ID: 180-153646-C-3 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

38.0869565217391None %

Dilution

Lab Sample ID: 180-153646-C-4 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

38.6172006745363None %

Dilution

Lab Sample ID: 180-153646-B-6 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

47.1624266144814None %

Dilution

Lab Sample ID: 180-153646-B-7 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

50.4504504504504None %

Dilution

Lab Sample ID: 180-153646-B-8 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

45.1939291736931None %

Dilution

Lab Sample ID: 180-153646-B-9 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

44.731977818854None %

Dilution

Lab Sample ID: 180-153646-B-10 Analysis Date: Mar 17, 2023 13:34

Percent Solids

Analyte Raw Result UnitDetector

47.2696245733788None %

Dilution

Eurofins Pittsburgh

Batch: 431066 Analyst Initials: S1Z Instrument: No EquipmentMethod: EPA 1664B

Lab Sample ID: MB 180-431060/1-A Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

2.2000000000002None mg/L

Dilution

Initial Final

Amount Amount

1000 mL 1000 mL

TPH (SGT-HEM) None 0.799999999999912 mg/L1 1000 mL 1000 mL

Lab Sample ID: LCS 180-431060/2-A Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

34.3999999999998None mg/L

Dilution

Initial Final

Amount Amount

1000 mL 1000 mL

TPH (SGT-HEM) None 14.7999999999997 mg/L1 1000 mL 1000 mL

Lab Sample ID: LCSD 180-431060/3-A Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

32.2None mg/L

Dilution

Initial Final

Amount Amount

1000 mL 1000 mL

TPH (SGT-HEM) None 13.7 mg/L1 1000 mL 1000 mL

Lab Sample ID: LB 180-430042/1-G Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

1.39999999999985None mg/L

Dilution

Initial Final

Amount Amount

750 mL 1000 mL

TPH (SGT-HEM) None 0.399999999999956 mg/L1 750 mL 1000 mL

Lab Sample ID: 180-153646-A-6-M Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

2.50000000000039None mg/L

Dilution

Initial Final

Amount Amount

810 mL 1000 mL

TPH (SGT-HEM) None 0.500000000000167 mg/L1 810 mL 1000 mL

Lab Sample ID: 180-153646-A-7-L Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

4.59999999999994None mg/L

Dilution

Initial Final

Amount Amount

800 mL 1000 mL

TPH (SGT-HEM) None 1.90000000000001 mg/L1 800 mL 1000 mL

Lab Sample ID: 180-153646-A-8-L Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

1.00000000000033None mg/L

Dilution

Initial Final

Amount Amount

750 mL 1000 mL

TPH (SGT-HEM) None 0.600000000000378 mg/L1 750 mL 1000 mL

Lab Sample ID: 180-153646-A-9-M Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

1.09999999999966None mg/L

Dilution

Initial Final

Amount Amount

820 mL 1000 mL

TPH (SGT-HEM) None 0.599999999999934 mg/L1 820 mL 1000 mL

Lab Sample ID: 180-153646-A-10-L Analysis Date: Apr 03, 2023 06:34

HEM (Oil & Grease)

Analyte Raw Result UnitDetector

0.900000000000123None mg/L

Dilution

Initial Final

Amount Amount

750 mL 1000 mL

TPH (SGT-HEM) None 0.599999999999934 mg/L1 750 mL 1000 mL

Batch: 433045 Analyst Initials: LWM Instrument: No EquipmentMethod: EPA 9040C

Lab Sample ID: LCS 180-433045/1 Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

7.01None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: LB 180-430042/1-A Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

4.36None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: 180-153646-A-6-D Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

12.07None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: 180-153646-A-7-D Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

11.98None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: 180-153646-A-8-D Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

12.05None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: 180-153646-A-9-E Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

12.05None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: 180-153646-A-10-D Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

12.03None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: LB 180-430795/1-A Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

5.87None SU

Dilution

Final

Amount

10 mL

Lab Sample ID: CCV 180-433045/12 Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

7.02None SU

Dilution

Final

Amount

10 mL

Temperature None 22.8 Celsius1 10 mL

Lab Sample ID: CCV 180-433045/23 Analysis Date: Apr 21, 2023 13:54 pH

Analyte Raw Result UnitDetector

6.98None SU

Dilution

Final

Amount

10 mL

Temperature None 22.8 Celsius1 10 mL

Subcontract Data

Shipping and Receiving Documents

Login Sample Receipt Checklist

Client: Battelle Job Number: 180-153646-1

Login Number: 153646

Question Answer Comment

Creator: Abernathy, Eric L

List Source: Eurofins Pittsburgh

List Number: 1

N/ARadioactivity wasn't checked or is </= background as measured by a survey meter.

TrueThe cooler's custody seal, if present, is intact.

TrueSample custody seals, if present, are intact.

TrueThe cooler or samples do not appear to have been compromised or tampered with.

TrueSamples were received on ice.

TrueCooler Temperature is acceptable.

TrueCooler Temperature is recorded.

TrueCOC is present.

TrueCOC is filled out in ink and legible.

TrueCOC is filled out with all pertinent information.

TrueIs the Field Sampler's name present on COC?

TrueThere are no discrepancies between the containers received and the COC.

TrueSamples are received within Holding Time (excluding tests with immediate HTs)

TrueSample containers have legible labels.

TrueContainers are not broken or leaking.

TrueSample collection date/times are provided.

TrueAppropriate sample containers are used.

TrueSample bottles are completely filled.

N/ASample Preservation Verified.

TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs

TrueContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").

TrueMultiphasic samples are not present.

TrueSamples do not require splitting or compositing.

N/AResidual Chlorine Checked.

Eurofins Pittsburgh Page 9427 of 9428

Login Sample Receipt Checklist

Client: Battelle Job Number: 180-153646-1

Login Number: 153646

Question Answer Comment

Creator: Armbruster, Chris

List Source: Eurofins Edison

List Creation: 03/20/23 12:48 PMList Number: 3

N/ARadioactivity wasn't checked or is </= background as measured by a survey meter.

N/AThe cooler's custody seal, if present, is intact.

N/ASample custody seals, if present, are intact.

TrueThe cooler or samples do not appear to have been compromised or tampered with.

TrueSamples were received on ice.

TrueCooler Temperature is acceptable.

TrueCooler Temperature is recorded. 2.7°C IR9

TrueCOC is present.

TrueCOC is filled out in ink and legible.

TrueCOC is filled out with all pertinent information.

TrueIs the Field Sampler's name present on COC?

TrueThere are no discrepancies between the containers received and the COC.

TrueSamples are received within Holding Time (excluding tests with immediate HTs)

TrueSample containers have legible labels.

TrueContainers are not broken or leaking.

TrueSample collection date/times are provided.

TrueAppropriate sample containers are used.

TrueSample bottles are completely filled.

TrueSample Preservation Verified.

TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs

TrueContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").

TrueMultiphasic samples are not present.

TrueSamples do not require splitting or compositing.

N/AResidual Chlorine Checked.

Eurofins Pittsburgh Page 9428 of 9428

Subcontracted Data
Shipping and Receiving Documents
Client Chain of Custody
Sample Receipt Checklist

File details come from the government source that posted it. Updated .