Amendment_0004_-_Plans.pdf
PDF 532 KB Posted
- Solicitation number
- W912DS-16-B-0013
About this file
Amendment 0004 Plans
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
/1
/2
:1
ES502
E L E
C T
R
IC
A L D
E T
A
IL
W
D S -1
-B -0
S H
E E
T O
F
OMAHA DISTRICT
M R
M
O M
A H
A D
IS
T R
IC
T P
H A
S
T H
U L E A
B
G R
E E
N L
A N
D
W W
C X P
O M
A H
A
N E
B R
A S
K A
E
S .d w g
N
S I
D
REQUIRED
LENGTH AS
(6) #4 REBAR,
#3 REBAR RINGS AT 6" ± O.C.
21" FOR SIZE C BASE
18" FOR SIZE B BASE
MAINTAIN MIN. 3" COVER ON REBAR
LIGHT
LED TAXIWAY EDGE
L-861T (L) ELEVATED
SUBJECT TO SNOW CONDITIONS.
ADJUSTED PER FIGURE ON THIS SHEET IN AREAS
STANDARD HEIGHT IS 14". HEIGHT MAY BE
BASIS FOR DESIGN - SHERWIN INDUSTRIES INC. MODEL S3639
FOR SNOWY / ICY CONDITIONS
TYPICAL LIGHT REFLECTOR MARKER
ASPHALT
PLAN (TYPICAL)
L-824-TYPE C PER
CABLE #6, 5 KV
CONNECTOR (STYLE 8)
L-823 SECONDARY
CONNECTOR
L-823 PRIMARY
L-868B, CLASS 1B, LIGHT BASE
NOTE 1
GROUND LUG
C
O W
N
NOTE 3
30" SQUARE OR ROUND
JOINT SEALANT
LEVELING SILICONE
SEAL WITH SELF-
ABOVE GROUND
OF PRIMARY LEADS TO BE MADE
CABLE TO PERMIT CONNECTION
PROVIDE 3 FEET OF SLACK
#4 BARE STRANDED COPPER GROUND
NOTE 5
NOTE 2
NOTE 4
TIE BAR CAGE
INTERNAL GROUND LUG.
GROUND STRAP BOLTED TO
GALVANIZING
POST WELDED TO BASE PRIOR TO
3/4" X 3" STAINLESS STEEL GROUND
EXOTHERMIC WELD (TYPICAL)
12" DEEP CRUSHED ROCK SUMP
OF CLOSED-CELL PLASTIC FOAM)
TRANSFORMER SUPPORT (6" CUBE
NOT TO SCALE
ELEVATED TAXIWAY EDGE LIGHT DETAIL
CONDUIT COUPLINGS
STEEL CONDUIT
GALVANIZED RIGID
CONDUIT (TYP.)
NON-METALLIC FLEXIBLE
LIQUID TIGHT
REPRESENTATIVE
AS DIRECTED BY BASE
WIDE GROUND GRID
CONNECT TO BASE
EXOTHERMIC CONNECTION
NOTES:
1. PROVIDE A 6 FOOT BRAIDED, #6 AWG EQUIVALENT GROUND STRAP WITH ONE-HOLE LUG COMPRESSION FITTINGS.
STRAPS SHALL BE MADE FOR THE PURPOSE OF GROUNDING THE LIGHT FIXTURE TO THE BASE CAN INTERIOR
GROUNDING LUG AND SHALL BE EQUIVALENT TO ADB PART #89A0292
2. FOR RUNWAY LIGHTS PROVIDE AN L-868B COVER PLATE W/ RECESSED 2" THREADED HUB (JAQUITH INDUSTRIES
#AK400012S OR EQUIVALENT). FOR TAXIWAY LIGHTS PROVIDE AN L-867B FIXTURE BASE PLATE WITH A 3/4"
CONVERSION RING (JAQUITH INDUSTRIES #AA5423 OR EQUVALENT).
3. STAINLESS STEEL BOLT WITH 2-PIECE LOCK WASHER.
4. L-868B SPACER RING WITH 5/8" PAVEMENT DAM. INSTALL SO THAT TOP OF DAM IS 1/8" BELOW PAVEMENT.
5. INTERIOR GROUND LUG AND EXTERNAL GROUND POST SHALL BE LOCATED 18" FROM BOTTOM OF BASE.
STEEL CONDUIT
GALVINIZED RIGID
REPRESENTATIVE
AS DIRECTED BY BASE
WIDE GROUND GRID
CONNECT TO BASE
EXOTHERMIC CONNECTION
#4 JUMPER
THREADED HUB
EXTENDED INTO SUMP
2" GALVINIZED RIGID STEEL DRAIN
TIE BAR CAGE
CONDUITS SHALL PROTRUDE INTO LIGHT BASE 3/4" FOR RIGID STEEL AND SHALL BE A MINIMUM 12" LONG.6.
7.
FOR THULE AB, GL FACILITIES
MEMORANDUM FOR 821SPTS/CE, SUBJECT WAIVER OF LIGHTING PROTECTION SYSTEMS REQUIREMENTS
THULE AIR FORCE BASE DOES NOT REQUIRE A COUNTERPOISE INSTALLED IN THE AIRFIELD LIGHTING SYSTEM PER
8. MAINTAIN GROUND MIN. 3" COVER ON REBAR
CONDUIT COUPLINGS
CONDUIT (TYP.)
NON-METALLIC FLEXIBLE
LIQUID TIGHT
REPRESENTATIVE
AS DIRECTED BY BASE
WIDE GROUND GRID
CONNECT TO BASE
EXOTHERMIC CONNECTION
PLAN (TYPICAL)
L-824-TYPE C PER
CABLE #6, 5 KV
NOTE 1
LUG
GROUND
NOTE 2
NOTE 3AS REQUIRED
SPACER RINGS SEAL WITH SELF-LEVELING
SILICONE JOINT SEALANT
NOT TO SCALE
IN-PAVEMENT TAXIWAY EDGE LIGHT DETAIL
FLEXIBLE PAVEMENT
CONNECTOR (STYLE 8)
L-823 SECONDARY
THE FIXTURE EDGE IS +0" AND -1/16"
FROM THE PAVEMENT TOP 30" SQUARE OR ROUND CONCRETE COLLAR
FIXTURE SHALL BE INSTALLED SUCH THAT L-850C SEMI-FLUSH RUNWAY EDGE LIGHT FIXTURE
(SEE DETAIL 3/E010)
L-823 PRIMARY CONNECTOR
ABOVE GROUND
OF PRIMARY LEADS TO BE MADE
CABLE TO PERMIT CONNECTION
PROVIDE 3 FEET OF SLACK
L-868, CLASS 1, LIGHT BASE
#4 BARE STRANDED COPPER GROUND
TIE BAR CAGE
INTERNAL GROUND LUG.
GROUND STRAP BOLTED TO
GALVANIZING
POST WELDED TO BASE PRIOR TO
3/4" X 3" STAINLESS STEEL GROUND
EXOTHERMIC WELD (TYPICAL)
OF CLOSED-CELL PLASTIC FOAM)
TRANSFORMER SUPPORT (6" CUBE
12" DEEP CRUSHED ROCK SUMP
STEEL CONDUIT
GALVANIZED RIGID
STEEL CONDUIT
GALVANIZED RIGID
REPRESENTATIVE
AS DIRECTED BY BASE
WIDE GROUND GRID
CONNECT TO BASE
EXOTHERMIC CONNECTION
#4 JUMPER
THREADED HUB
EXTENDED INTO SUMP
2" GALVINIZED RIGIN STEEL DRAIN
MAINTAIN MIN. 3" COVER ON REBAR9.
WAIVER OF LIGHTING PROTECTION SYSTEMS REQUIREMENTS FOR THULE AB, GL FACILITIES
THULE AIR FORCE BASE DOES NOT REQUIRE A COUNTERPOISE INSTALLED IN THE AIRFIELD LIGHTING SYSTEM PER MEMORANDUM FOR 821SPTS/CE, SUBJECT 8.
7. CONDUITS SHALL PROTRUDE INTO LIGHT BASE 3/4" FOR RIGID STEEL AND SHALL BE A MINIMUM 12" LONG.
6. ORIENTATION TOLERANCE FOR THE BASE IS ±1/2 DEGREE FROM THE CENTERLINE SHOWN ON THE PLANS.
INTERIOR GROUND LUG AND EXTERNAL GROUND POST SHALL BE LOCATED 18" FROM THE BOTTOM OF BASE. 5.
INSTALL BASE WITH FURNISHED PLYWOOD COVER DESIGNED TO PROVIDE BLOCKOUT IN PAVEMENT TO ALLOW PROPER INSTALLATION OF SNOWPLOW RIG.4.
SO THAT FIXTURE INSTALLATION TOLERANCE ARE MET.
STYLE 3 SNOW PLOW RIG (EQUIVALENT TO JAQUITJ INDUSTRIES AW544400). INSTALL PER MANUFACTURER'S RECOMENDATIONS AND WITHSPACER RINGS3.
TRENCH CONDUIT INTO EXISTING SUB-BASE COURSE.2.
PURPOSE OF GROUNDING THE LIGHT FIXTURE TO THE BASE OG THE CAN INTERIOR GROUNDING LUG AND SHALL BE EQUIVALENT TO ADB PART #89A0292
PROVIDE A 6 FOOT BRAIDED, #6 AWG EQUIVALENT GROUND STRAP WITH ONE-HOLE LUG COMPRESSION FITTINGS. STRAPS SHALL BE MADE FOR THE1.
ES502
ES502
NOT TO SCALE
TIE BAR CAGE DETAIL 3
ES502
ISOLATION TRANSFORMER
6.6A/6.6A
TRANSFORMER
ISOLATION
6.6A/6.6A
A
M
G
E N
E R
A L R
E V
IS
IO
N /0
/2
S
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
/1
/2
:1
ES503
E
C T
R
IC
A L D
E T
A
IL
E
E T O
F
OMAHA DISTRICT
M R
E P
L A
C E R
U N
W A
Y P
A V
E M
E N
M
O M
A H
A D
IS
T R
IC
T P
H A
S
U L E A
B
G R
E E
N L
A N
D
W W
C X P
O M
A H
A
N E
B R
A S
K
E
S .d w g
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
/1
/2
A N
S I
D
AMERACE 54 SUPER KIT CONNECTOR-PLUG CONNECTED TO CABLE
R01E-1
PIN RECEPTACLE
12 INCHES
R01E-1
L-824 CABLE SPLICE AND CONNECTOR DETAIL
NO SCALE
STAMPED (NOT ETCHED)
3/8 IN. TEXT - MACHINE
18 GAUGE, STAINLESS STEEL
CABLE TAGS, 2 IN. DIA.,
L-824 CONNECTOR
INSTALL CABLE TAGS WITH
CLEAN CABLE SHEATH W/ SUITABLE SOLVENT
CABLE
HOUSING
RECEPTACLE
COPPER WIRE TIE
12AWG SOLID
PEEL BACK PORTION OF CONNECTOR KIT
PLUG HOUSING
L-824 CABLE (5KV)
3/16 IN. HOLE
APPROVED EQUIVALENT)
(ELASTIMOLD OR
L-824 CONNECTOR LIT
FINISHED GRADE
JUNCTION BOX
FAA TYPE L-858Y FOR TACAN SIGN
FAA TYPE L-858R FOR RUNWAY HOLD SIGNS
MANDATORY AND INFORMATION GUIDANCE SIGNAGE
OR GRAVEL LAYER
COMPACTED SUBGRADE
AIRFIELD GUIDANCE SIGN DETAIL
NOT TO SCALE
SIZE 3 SIGN: 36"-42"
OVERALL MOUNTING HEIGHT
12" MIN.
1/2" CHAMFER
(PLACE MID-SLAB)
SPACING EACH WAY
#4 REBAR AT 12"
GROUND ROD WITH #8 XHHW
GROUND BASE TO 3/4" x 10"
6"
6"
STEEL CONDUIT
GALVANIZED
2" RIGID
DETAILS FOR MOUNTING OPTIONS
(TYP) SEE SIGN BASE POWER LEG MOUNTING
BREAKABLE COUPLING AND DISCONNECT PLUG
TOP OF BASE FLUSH WITH CONCRETE PAD
L-867, SIZE B 12" CLASS I BASE
NOTES:
7. RUNWAY HOLD SIGNS SHALL BE SIZE 3, STYLE 2
6. CONCRETE FOUNDATION SHALL BE FLUSH WITH FINISHED GRADE.
5. CONSIDER 3" ASPHALT OR 4" GRAVEL STRIP, 3'-0" WIDE AROUND FOUNDATION FOR PROTECTION.
4. PROVIDE TETHERS, MINIMUM 2 PER SIGN.
SIZE 3 - 170" MINIMUM OVERAL SIGN LENGTH: SIZE 3 - 42 INCHES3. MAXIMUM OVERALL SIGN LENGTH:
SLOPE FOUNDATION SURFACE TO DRAIN AWAY FROM SIGN, APPROX. 2% (1/4" / FT)
WIDTH = MININUM 3'-0". PROVIDE 12" CLEAR ON ALL SIDES OF SIGN.
THICKNESS = 12"2. FOUNDATION:
3500 PSI MINIMUM STRENGTH
REINFORCED CONCRETE PAD
(35-60 FEET FROM EDGE OF TAXIWAY).
OFFSET ALL SIZE 3 SIGNS PER DRAWINGS
CABLE CLAMP
BASEPLATE
FRANGIBLE COUPLING
CABLE CLAMP
TRANSFORMER
FROM ISOLATION
STYLE 8
L-823
FROM SIGN
POWER CORD
SECONDARY
L-823 STYLE 7
SECONDARY
L-823 STYLE 8
CLIPS
RETAINER
HANDHOLE
L-867
TO
HANDHOLE
TO L-867
CONCRETE PAD
SURFACE OF
HUB
W/THREADED
FLOOR FLANGE
SIGN BASE POWER LEG MOUNTING DETAILS
NOT TO SCALE
ELBOW AND FLOOR FLANGE MOUNTING
JUNCTION BOX MOUNTING
DIA. LIGHT BASE
L-867 12"
2" FRANGIBLE COUPLING
GROMMET
3" DEEP
CONDUIT TO L-867 HANDHOLE
2" RIGID GALVANIZED STEEL
SET FLUSH W/ TOP OF PAD
2" THREADED COUPLING
RIGID ELBOW
2" 90 °
4" FROM TOP OF CAN AT 90° INCREMENTS
4 EACH 2" X 2" X 3/8" L HOOKS LOCATED
AS SHOWN HERE, NOT AS SHOWN ON ED102.
AS SHOWN ON ED102. WIRING SHALL BE CONDUCTED
INSTALL A BASE PLATE INSTEAD OF LIGHT FIXTURE
ES503
ES503
1A
ES503
1B
ES503
ATTACH BOTTOM TO BOLT
TETHER (TYP.)
W
D S -1
-B -0
SEE SHEET E102 FOR LIGHT BASE CAN DETAIL.
SHALL BE 0.25" ABOVE THE CONCRETE PAD ±0.125"
CAN SHALL BE LEVEL WITHIN 2 DEGREES AND
THREADED HUB. UPPER SURFACE OF THE BASE
L-867, SIZE B BASE CAN WITH 2 IN.
A
M
G
E N
E R
A L R
E V
IS
IO
N /0
/2
S L
File details come from the government source that posted it. Updated .