B.08.03 AMD 0002 W912DR22B0011_8-4-22.pdf
PDF 858 KB Posted
- Attached to
- Letterkenny Army Depot (LEAD) Building 370 Interior Renovations Task 1, LEAD, Chambersburg, PA
- Solicitation number
- W912DR22B0011
About this file
This amendment modifies the solicitation for the Letterkenny Army Depot Building 370 Interior Renovations Task 1 project. The full renovation of the second floor will outfit approximately 40,000 square feet of space for multipurpose "pod" use, including maintenance of small electronics at desks. Notable requirements include raised access flooring and power strips along walls. Mechanical, electrical, fire alarm, and sprinkler systems will be removed and replaced throughout the building. Hazardous material remediation will be limited to areas impacted by construction. The amendment provides revised sheets for the partial second floor plan and interior finish schedule, and extends the response date to August 12, 2022. The opportunity is a 100% small business set-aside for the U.S. Army Corps of Engineers, Baltimore District.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
PROJECT NAME: Letterkenny Army Depot (LEAD) Building 370 Interior Renovations, Task 1, Chambersburg, PA
The purpose of this Amendment (0002) is to:
1. Provide revised Sheet A-101
2. Provide revised Sheet I-601
All other terms and conditions remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 04-Aug-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912DR22B0011
X 9B. DATED (SEE ITEM 11)
08-Jul-2022
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or
(c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
04-Aug-2022
CODE
USACE, BALTIMORE
2 HOPKINS PLAZA
BALTIMORE MD 21201
W912DR 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912DR22B0011
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION 00 10 00 - SOLICITATION
The required response date/time has changed from 09-Aug-2022 11:00 AM to 12-Aug-2022 11:00 AM.
(End of Summary of Changes)
LEAD BLDG. 370 INTERIOR RENOVATION – TASK 1
AMENDMENT 0002
AMENDMENTS:
1) Sheet A-101: Delete this sheet in its entirely as reissued by Amendment 0001 and substitute the attached revised sheet dated 08/02/2022.
2) Sheet I-601: Delete this sheet in its entirely as reissued by Amendment 0001 and substitute the attached revised sheet dated 08/02/2022.
DN
DN
DN
I I
2 2
1.1N 1.1N
2N 2N
3N 3N
4N 4N
5N 5N
6N
6N
W V U T S R P
N M L JJ
1E 1E
A-301
3689 SF
INDUST TEST
EQUIP
1600 SF
MECHANICAL
407 SF
WIP STORAGE
371 SF
BREAK
5343 SF
LAB REPAIR
AREA 1
894 SF
CLASSROOM
10737 SF
LAB REPAIR
AREA 2
244 SF
SUPERVISORS
115 SF
UTILITY
304 SF
ELECTRICAL
282 SF
BREAK
208 SF
FIBER NODE RM
605 SF
SUPERVISORS
708 SF
CORRIDOR
201A
203A
205B
213B 211
206A
112 SF
IDF/COM
/2
24'-9"
44'-6"
66'-2" + or - / FIELD VERIFY
53'-5" + or - / FIELD VERIFY
12'-4"
20'-7" + or - / FIELD VERIFY
17'-3"
/2
/4
RAISED FLOOR RAMP
UP
RAISED FLOOR RAMP
UP
PROVIDE TEMPORARY RAMP
FOR RAISED FLOOR SYSTEM
CONSTRUCTED OF RAISED
FLOOR SYSTEM FOR REUSE IN
PHASE 2.
206B
PROVIDE TEMPORARY
YELLOW WARNING TAPE
AT ELEVATION CHANGE
203B
201B
200B
MATCH LINE A-102
A0
C0
B0
M
IN
14'-0"
LOCATE WALL FLUSH WITH
EXISTING. PROVIDE TEAR-AWAY
(ZIP STRIP) TRANSISTION TO CMU
WALL
213A E0
A-401
469 SF
CORRIDOR
200B
159 SF
CORRIDOR
200A
202A
TENANT
B0B0
B0
B0
B0
B0
B0
C0
C0
12'-0"
B0
A0
PROVIDE TEMPORARY RAILING
AT RAISED FLOOR AND RAMP
CONSTRUCTION OF RAILING
SHALL MEET ALL OSHA & EM
385-1-1 REQUIREMENTS
B0
E0
E0
E0
MATCH LINE A-102
NEW KNEE WALL PARTITION W/
SOLID SURFACE CAP AND SS
CORNER GUARDSK
K
1'-10"
PROVIDE WALL MOUNTED HANDRAIL
SEE SHEET A-603 FOR DETAILS
PROVIDE WALL MOUNTED HANDRAIL
AT RAMP. SEE SHEET A-603 FOR
DETAILS
B0
M1
M1
M1
A-301
6' - 4"
DOORS TO BE REMOVED AT THE
END OF CONSTRUCTION TO ALLOW
EXIT EGRESS
EXISTING ELEC.
PANEL TO REMAIN
EXISTING STAIR, RAILING, WALLS AND
CEILING TO BE PAINTED. INSTALL
NEW RUBBER TREADS AND RISERS
S
S
S
S
S
SSS SS
S SS
201C
50'-9" + or - / FIELD VERIFY
1. SEE SHEET A-001 FOR ANNOTATION SYMBOLS
2. FOR DOOR TYPES AND SCHEDULE SEE SHEET A-601.
3. FOR PARTITION TYPE INFORMATION SEE SHEET A-501 AND A-502
4. ALL NEW DOORS SHALL BE LOCATED 6" FROM CLOSEST INTERIOR WALL CORNER OR AS
OTHERWISE DIMENSIONED.
5. CONTRACTOR TO ENSURE ALL FIRE RATED PARTITIONS ARE MAINTAINED AND EXTEND FROM
FLOOR TO BOTTOM OF DECK.
6. CONTRACTOR TO PROVIDE ALL NECESSARY MISCELLANEOUS FIRE CAULKING AND GASKETING
TO PROVIDE A COMPLETE RATED WALL WHERE INDICATED ON A-101, A-102 & A-103 TO INCLUDE
WALL INFILL AT EXISTING AND NEW PENETRATION AND DEMOLISHED WINDOWS IN ROOMS 217,
219, 221 & 225.
7. FOR MECHANICAL EQUIPMENT DESCRIPTION SEE MECHANICAL DWGS.
8. ALL EXPOSED STEEL COLUMNS AND CROSS BRACING TO BE SANDED SMOOTH AND PAINTED
PNT 5.
9. DIMENSIONS TO BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF WORK. CONFLICTS
GREATER THAN 2" AFFECTING PLACEMENT OF NEW WORK SHALL BE RESOLVED THROUGH THE
COR PRIOR TO CONSTRUCTION.
10. EXTENT OF NEW ARCHITECTURAL WORK ON FIRST FLOOR LIMITED TO IDF/COM ROOM 101
LOCATED DIRECTLY BELOW NEW SECOND FLOOR IDF/COM ROOM 221 AND TR ROOM 102. SEE
SHEE A-103
11. SEE SHEETS A-401 & A-402 FOR BREAKROOM DETAILS
12. FOR FURNITURE AND EQUIPMENT PLAN LAYOUTS REFER TO SHEETS I-101 AND I-102 ALL
FURNITURE SHOWN IS NOT IN CONTRACT.
13. ALL EXPOSED EXISTING CMU WALLS TO REMAIN SHALL BE SCRAPED, PATCHED, SANDED,
PRIMED AND PAINTED TWO COATS OF FINISH PAINT.
14. ALL FACES OF NEW WALLS WITHIN ROOMS 200A, 201, 203, 205, 207 & 214 SHALL HAVE ABUSE
RESISTANT GYP BD UP TO 8' ABOVE FINISHED FLOOR.
NOTES:
LEGEND:
INDICATES NEW WALL CONSTRUCTION SEE WALL TYPES FOR DETAILS.
EXISTING COLUMN GRID LINE
1 HOUR RIRE RATED PARTITION ( "S" INDICATES SMOKE PARTITION ONLY)
2 HOUR FIRE RATED PARTITION
REPAIR AND PATCH EXISTING GWB/PLASTER TO LEVEL 4 FINISH. PAINT PER FINISH SCHEDULE
REMOVE EXISTING FLOOR & BASE. INSTALL NEW LVT FLOORING & BASE PER FINISH
SCHEDULE
INSTALL NEW PAIRED PANEL FOLDING PARTITION SYSTEM CONTRACTOR TO PROVIDE
STRUCTURE FOR TOP TRACK
FILL OPENING WITH ONE HOUR GWB ASSEMBLY FINISH ACCORDINGLY
FILL OPENINGS WITH RATED WALL ASSEMBLY AND PATCH PRIME AND PAINT ALL WALLS.
INSTALL NEW SUSPENDED ACOUSTICAL CEILING SYSTEM AND NEW CARPETING.
PREP, PRIME AND PAINT EXISTING DOOR AND FRAME.
X
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N
O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A-101
P A
R T
IA
L S
E C
O N
D F
L O
O R
P L A
N
A R
E A
A
L E
T T
E R
K E
N N
Y A
R M
Y D
E P
O
P
E N
N S
Y L V
A N
IA
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
A R
Y L A
N D
U S
A C
E E
N G
IN
E
E R
IN
G
S U
P P
O R
T C
E N
T E
R
H U
N T
S V
IL
L E
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
A R
C H
IT
E
C T
U R
A L B
R A
N C
H
D H
A W
K
D H
A W
K
R O
L M
E D
O
J U
N
F
IR
S T
T
IT
L E
L E
A D
B U
IL
D
IN
G
I N
T E
R
IO
R R
E N
O V
A T
IO
N
S
T A
S K
BALTIMORE DISTRICT
3/32" = 1'-0"A-101
1 PARTIAL SECOND FLOOR PLAN - AREA "A"
R e v is e d b y a m e n d m e n t
/2
/2
R e v is e d b y a m e n d m e n t
/0
/2
2ND FLOOR KEY PLAN
N
SCALE: 3/32"=1'-0"
816 16
ACOUSTICALLY RATED PARTITIONS SHALL PROVIDE NO LESS
THAN THE MINIMUM STC RATINGS INDICATED. (TYP.)
1.
FIRE RATED & ACOUSTICAL PARTITIONS SCHEDULED AS
RATED ASSEMBLIES REQUIRED CONTINUOUS &
UNINTERRUPTED SEPARATIONS IN ACCORDANCE WITH
APPLICABLE CODE & TESTED ASSEMBLIES INDICATED.
SEPARATIONS SHALL INCLUDE SAFING & SEALS AT
CORNERS, TERMINATIONS, PENETRATIONS, PLENUMS,
COLUMN ENCLOSURES, & ELECTRICAL BOXES, AS WELL AS
AT PHYSICAL INTERRUPTIONS, SUCH AS COLUMNS, BEAMS,
JOISTS, TRUSSES, & FLOORS, ETC. CONTRACTOR SHALL BE
RESPONSIBLE FOR ASSURING CONTINUOUS
UNINTERRUPTED SEPARATIONS AS SCHEDULED. (TYP.)
2.
PROVIDE PRIME COAT PAINT FINISH FOR ALL GWB
SURFACES THROUGHOUT, INCLUDING SURFACES NOT
EXPOSED SUCH AS AT CEILING & FLOOR PLENUMS. ALL
EXPOSED GWB SURFACES SHALL BE PROVIDE ADDITIONAL
PAINT COAT FINISHED AS SPECIFIED & SCHEDULED (TYP.)
3.
WHERE WALL HUNG ITEMS ARE INDICATED AS EITHER
SURFACE & / OR RECESSED, PROVIDE BLOCKING
CONCEALED WITHIN PARTITION FRAME ASSEMBLY. WALL
MOUNTED ITEMS SHALL INCLUDE, BUT NOT BE LIMITED
TOO; WATER FOUNTAINS, FIRE EXTINGUISHER CABINETS,
TOILET ACCESSORIES, TOILET PARTITIONS, CASEWORK,
COUNTERTOPS, MIRRORS, ETC. METHOD OF BLOCKING TO
BE APPROVED BY CONTRACTING OFFICER. EXPAND &
OVERSIZE AREA OF BLOCKING 20% LARGER THAN WALL
HUNG ITEM SCHEDULED, SPECIFICALLY ASSURING FINAL
LOCATION OF SURFACE MOUNTED ITEMS WILL BE
ACCOMMODATED (TYP.).
4.
NOTES:
ALL VISIBLE AND EXPOSED STRUCTURAL STEEL,
CONDUIT, SPRINKLER PIPE, DUCTWORK AND
MISCELANEOUS BRACING AT OR ABOVE THE
HEIGHT OF THE CEILING CLOUDS IN LAB REPAIR
AREA 1 & 2 (ROOMS 205 & 207) SHALL BE PAINTED
PT2 UNLESS REQUIRED TO NOT BE PAINTED BY ANY
APPLICABLE CODE OR UFC.
5.
BRACE PARTITION STUD FRAMES TO STRUCTURE ABOVE
AS FOLLOWS:
6.
PARTITIONS SCHEDULED FOR AREAS OF KNOWN OR
EXPECTED EXPOSURE TO WATER SHALL BE MODIFIED BY
CONTRACTOR AS FOLLOWS: REPLACE GWB INDICATED ON
EXPOSED SIDE(S) OF PARTITION WITH CEMENTITIOUS
BACKER BOARD IN THE SAME THICKNESS, & INSTALL
CONTINUOUS & UNIFORM 4-MIL POLYETHYLENE MEMBRANE
BACKING BEHIND CEMENTITIOUS BACKER. PREPARE
EXPOSED SURFACE OF CEMENTITIOUS BACKER FOR
SCHEDULED FINISHES. AREAS OF EXPECTED WATER
EXPOSURE ARE DEFINED AS – SHOWER ROOMS, ETC…
7.
PARTITIONS SCHEDULED FOR AREAS OF KNOWN OR
EXPECTED EXPOSURE TO MOISTURE SHALL BE MODIFIED BY
CONTRACTOR AS FOLLOWS: REPLACE GWB INDICATED ON
EXPOSED SIDE(S) OF PARTITION WITH MOISTURE RESISTANT
GWB OF THE SAME THICKNESS, & PREPARE EXPOSED
SURFACE FOR SCHEDULED FINISHES. AREAS OF EXPECTED
MOISTURE ARE DEFINED AS – TOILET ROOMS, JANITOR
CLOSETS, SINK SURROUNDS, VESTIBULES, ETC… (TYP.)
8.
PENETRATIONS THROUGH FIRE RESISTANT
ASSEMBLIES SHALL BE FIRE-STOPPED WITH SAFING
AS SPECIFIED. (TYP.)
9.
SUPPLY FULL HEIGHT PARTITIONS USING TWO
CONTINUOUS TOP TRACKS, WITH TOP TRACK BEING
A DEEP LEG DEFLECTION TRACK FASTENED
DIRECTLY TO DECK & PROVIDING SPACE FOR
STRUCTURAL DEFLECTION WITHOUT DAMAGE
CAUSED TO PARTITION ASSEMBLY.
PARTIAL HEIGHT PARTITIONS WITH SPLAYED
METAL STUD BRACING FASTENED DIRECTLY TO
STRUCTURE ABOVE. PROVIDE SPLAYED
BRACING ON BOTH SIDES OF ASSEMBLY AT NO
MORE THAN 4 FEET ON CENTER.
A -
B -
WHERE FLOOR FINISHES ARE DESIGNATED WITH
RF1 FOLLOWED AN ADDITIONAL FINISH, THE
SECOND FINISH LISTED IS APPLIED TO THE RAISED
FLOOR.
10.
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C
N
O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
I-601
IN
T
E R
IO
R
F
IN
IS
H
S C
H E
D U
L E
L E
T T
E R
K E
N N
Y A
R M
Y D
E P
O
P
E N
N S
Y L V
A N
IA
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
A R
Y L A
N D
U S
A C
E E
N G
IN
E
E R
IN
G
S U
P P
O R
T C
E N
T E
R
H U
N T
S V
IL
L E
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
A R
C H
IT
E
C T
U R
A L B
R A
N C
H
D H
A W
K
D H
A W
K
R O
L M
E D
O
J U
N
F
IR
S T
T
IT
L E
L E
A D
B U
IL
D
IN
G
I N
T E
R
IO
R R
E N
O V
A T
IO
N
S
T A
S K
BALTIMORE DISTRICTROOM FINISH SCHEDULE
ROOM
NO ROOM NAME FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH CEILING HEIGHT COMMENTS
FIRST FLOOR
100 CORRIDOR SC1 RB1 PNT1 PNT2 9'-6"
101 WORKSHOP EXISTING EXISTING EXISTING - OPEN TO ABOVE / EXISTING
102 WORKSHOP EXISTING EXISTING EXISTING - OPEN TO ABOVE / EXISTING
103 CORRIDOR SC1 RB1 PNT1 PNT2 9'-6"
104 WORKSHOP EXISTING EXISTING EXISTING - OPEN TO ABOVE / EXISTING
105 WORKSHOP EXISTING EXISTING EXISTING - OPEN TO ABOVE / EXISTING
106 CORRIDOR SC1 RB1 PNT1 PNT2 9'-6"
107 MEN'S RR EXISTING EXISTING EXISTING - EXISTING
108 JC EXISTING EXISTING EXISTING - EXISTING
109 TOILET EXISTING EXISTING EXISTING - EXISTING
150 IDF/COM SC1 RB1 PNT1 - OPEN TO ABOVE / EXISTING
160 TR SC1 RB1 PNT1 - OPEN TO ABOVE / EXISTING
02 FLOOR PLAN OVERALL DOC
200A CORRIDOR RF1 / LVT1 RB1 PNT1 PNT2 EXISTING
200B CORRIDOR RF1 / LVT1 / EJC1 RB1 PNT1 PNT2 8'-6" ABOVE RAISE FLOOR
201 INDUST TEST EQUIP SC1 RB1 PNT1 PNT2 EXISTING
202 MECHANICAL SC1 RB1 PNT1 - EXISTING
203 WIP STORAGE RF1 RB1 PNT1 ACT1 8'-6" ABOVE RAISE FLOOR
204 BREAK RF1/LVT1 RB2 PNT1 & PNT4 ACT1 8'-6" ABOVE RAISE FLOOR
205 LAB REPAIR AREA 1 RF1 RB1 PNT1 PNT2 & ACC1 VARIES - CLOUDS AT 8'-6"
ABOVE RAISED FLOOR"
PN5 ON ALL EXPOSED COLUMNS AND
BRACING BELOW CEIING LINE
206 CLASSROOM RF1/CPT1 RB2 PNT1 & PNT4 ACT1 8'-6" ABOVE RAISE FLOOR
207 LAB REPAIR AREA 2 RF1 RB1 PNT1 PNT2 & ACC1 VARIES - CLOUDS AT 8'-6"
ABOVE RAISED FLOOR"
PN5 ON ALL EXPOSED COLUMNS AND
BRACING BELOW CEIING LINE
208 SUPERVISORS RF1 / LVT1 RB2 PNT6 ACT1 8'-6" ABOVE RAISE FLOOR
209 UTILITY SC1 RB1 PNT1 - EXISTING
210 ELECTRICAL SC1 RB1 PNT1 - EXISTING
211 BREAK LVT1 RB2 PNT1 & PNT4 ACT1 9'-0" ABOVE FINISHED FLOOR
212 FIBER NODE RM LVT1 RB1 PNT1 ACT1 9'-0" ABOVE FINISHED FLOOR
213 SUPERVISORS LVT1 RB2 PNT6 ACT1 9'-0" ABOVE FINISHED FLOOR
214 CORRIDOR LVT2 / EJC1 RB3 PNT1 ACT1 9'-0" ABOVE FINISHED FLOOR
215 SUPERVISOR RF1/LVT1 RB2 PNT5 ACT1 8'-6" ABOVE RAISE FLOOR
216 DOIM OFFICE RF1/LVT1 RB2 PNT3 ACT1 8'-0" ABOVE RAISE FLOOR
217 DOIM ADMIN RF1/LVT1 RB2 PNT1 - 8'-0" ABOVE RAISE FLOOR
218 TEAM ROOM RF1/LVT2 RB1 PNT4 ACT1 8'-0" ABOVE RAISE FLOOR
219 DOIM SERVER LAB RF1 RB1 PNT1 - OPEN TO ABOVE / EXISTING
220 CORRIDOR LVT2 RB1 PNT4 ACT1 EXISTING
221 BREAK RF1/LVT1 RB3 PNT3 ACT1 9'-0" ABOVE FINISHED FLOOR
222 SUPERVISOR RF1/LVT1 RB2 PNT5 ACT1 8'-6" ABOVE RAISE FLOOR
223 COMM RF1 RB1 PNT1 - OPEN TO ABOVE / EXISTING
224 IDF/COM SC1 RB1 PNT1 - OPEN TO ABOVE / EXISTING
225 TENANT CPT1 RB1 PNT1 ACT1 9'-0" ABOVE FINISHED FLOOR
2ND FLR RAISED FLOOR
227 MECH MEZZANINE
230 STAIR
R e v is e d b y a m e n d m e n t
/2
/2
R e v is e d b y a m e n d m e n t
/0
/2
SCHEDULE - INTERIOR MATERIAL & COLOR BASIS OF DESIGN
FINISH DESCRIPTION MANUFACTURER STYLE COLOR COMMENTS ALTERNATE MANUFACTURERS
ACC 1 ACOUSTICAL CEILING
CLOUDS
ARMSTRONG SQUARE 4X8 (3'-10" X 7'-10") WHITE COORDINATE WHITE COLOR SELECTION USG, CERTAINTEED
ACT 1 ACOUSTICAL CEILING TILE ARMSTRONG OPTIMA TEGULAR 3354 WHITE MATCH EXISTING LEAD STANDARD USG, CERTAINTEED
CPT 1 CARPET TILE BENTLEY 18" x 36" 801532 - REDACTED DOCUMENT HERRINGBONE PATTERN INTERFACE
EJC 1 EXPANSION JOINT COVER INPRO 221 SERIES GRAY FIELD VERIFY FIT
LVT 1 LUXURY VINYL TILE ARMSTRONG LUXE PLANK 9" X 60" CONCRETE STRUCTURES - SOHO GRAY
LVT 2 LUXURY VINYL TILE ARMSTRONG 36"X36" WOVEN IMPRESSIONS FLAX
PLM1 PLASTIC LAMINATE LAMINART 3103T LACQUERED COCO VANITY COVER AND CUSTOM MILLWORK WILSONART
PNT 1 WALL PAINT SHERWIN WILLIAMS WASHABLE EGGSHELL FINISH SW7063 (NEBULOUS WHITE) BENJAMIN MOORE
PNT 2 CEILING PAINT SHERWIN WILLIAMS WASHABLE EGGSHELL FINISH SW7007 (CEILING BRIGHT WHITE) BENJAMIN MOORE
PNT 3 HM FRAME PAINT SHERWIN WILLIAMS HIGH PERFORMANCE FINISH - SEMI GLOSS SW7066 (GRAY MATTERS) PROVIDE MANUFACTURERS STANDARD FINISH
SAMPLES
BENJAMIN MOORE
PNT 4 ACCENT WALL PAINT SHERWIN WILLIAMS WASHABLE EGGSHELL FINISH SW2850 (CHELSEA GRAY) BENJAMIN MOORE
PNT 5 ACCENT STEEL PAINT SHERWIN WILLIAMS HIGH PERFORMANCE FINISH - SATIN SW7674 (PEPPERCORN) BENJAMIN MOORE
PNT 6 OFFICE WALL PAINT SHERWIN WILLIAMS WASHABLE EGGSHELL FINISH SW7641 (COLONADE GRAY)
RB 1 RUBBER BASE TARKETT COVER BASE 6" SILVER GRAY COORDINATE WITH LVT FLOORING JOHNSONITE
RB 2 RUBBER BASE TARKETT COVER BASE 6" DARK BROWN RAISED FLOOR AREA JOHNSONITE
RF1 RAISED FLOOR PANEL TEC-CRETE POLISHED CONCRETE CLEAR PROVIDE MANUFACTURERS STANDARD FINISH
SAMPLES
SC 1 SEALED CONCRETE SHERWIN WILLIAMS CLEAR GRIND AND POLISH EXISTING CONRETE
SMOOTH
BENJAMIN MOORE
SS1 SOLID SURFACE DUPONT CORIAN CUSTOM FABRICATION WILLOW GIBRALTER
ST1 PREFINISHED VENEER
DOOR STAIN
MASONITE OAK VENEER FILLED GRAIN ESPRESSO
| LEAD BLDG. 370 INTERIOR RENOVATION – TASK 1 - AMENDMENT 0002.pdf |
| NARRATIVE |
| REVISED SHEET A-101 - PARTIAL SECOND FLOOR PLAN - AREA "A" |
| REVISED SHEET I-601 - INTERIOR FINISH SCHEDULE |
File details come from the government source that posted it. Updated .