I.A.02.10_Attachment_B_-_Plans.pdf
PDF 35 MB Posted
- Attached to
- Jennings Randolph Tainter Gate Upgrade Federal contract opportunity
- Solicitation number
- W912DR19B0006
About this file
Plans
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| I.C.04.01_Abstract_of_Bids_-_JRL_Electrical_Upgrade.pdf | ||
| I.B.08.03_W912DR19B0006-0003.pdf | ||
| I.B.08.03_W912DR19B006-0002.pdf | ||
| I.B.08.03_W912DR19B0006-0001.pdf | ||
| I.A.02.10_Attachment_D_-_EFT_FORM.PDF | ||
| I.A.02.10_Attachment_E_-_Certificate_of_Corporate_Authority_Form.PDF | ||
| I.A.02.10_Attachment_A_-_Specifications.pdf | ||
| I.A.02.10_Attachment_C_-_Standard_Form_LLL.PDF | ||
| I.B.01.01_Solicitation_W912DR19B0006.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAJ.RONALD
.J.1228710152
Digitally signed by
MAJ.RONALD.J.1228710152
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=MAJ.RONALD.J.1228710152 Date: 2018.11.27 18:11:22 -05'00'
S O
L I C
I T
A T
I O
N
N
O
F I L E
N
A M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
C T
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
P O
R T
L A
D
I S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
G-001
J E
N N
I N
G
R
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
U
G
R A
D E
D R
A W
I N
G
I N
D E
X
E
R
I M
K E
E
G E
C D
T R
S G
E
C D
J P
B
W I L L I A
M
F
O R
T U
Y
E
S I
D
J R
L
G
X X
X d w g
BALTIMORE DISTRICT
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
D
I S
T R
I C
T
B A
L T
I M
O R
E
M
A R
Y L
A N
D
SPILLWAY AREA OF WORK
AERIAL VIEW OF JENNINGS-RANDOLPH LAKE AND DAM
MARYLAND
WEST VIRGINIA
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
G-002
J E
N N
I N
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
G
R A
D E
A B
B R
E V
I A
T I O
N
L I S
T
E
R
I M
K E
E
G E
C D
T R
S G
E
C D
J P
B
W I L L I A
M
F
O R
T U
E
S I
D
J R
L
G
X X
X d w g
BALTIMORE DISTRICT
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
D
I S
T R
I C
T
B A
L T
I M
O R
E
M
A R
Y L
A N
D
- J -
- K -
- A -
- E -
- D -
- B -
ABBREVIATIONS
THE FOLLOWING ABBREVIATIONS MAY BE USED ON THE DRAWINGS IN THIS VOLUME
- I - - P -
- U -
- T -
DATUM
DOUBLE
DIRECT CURRENT
DEGREE
DEPARTMENT
DETAIL
DISCREET INPUT
DIAMETER
DIMENSION
DISCONNECT
DIVISION
DOWN
DEVICENET
DISCREET OUTPUT
DOOR, DRAIN
DISCONNECT SWITCH
DOWNSTREAM
DEVICENET STARTER ASSEMBLY
DRAWING
DUPLEX
DAT
DBL
DC
DEG
DEPT
DET
DI
DIA or Ø
DIM
DISC
DIV
DN
DNET
DO
DR
DS
D/S
DSA
DWG
DX
EAST
EACH
ELEVATION - GRADE OR BUILDING
ELECTRIC or ELECTRICAL
ENCLOSURE
ENTRANCE
EQUAL
EQUIPMENT
ESTIMATE
EXHAUST
EXISTING
EXPANSION, EXPOSED
EXTERIOR
E
EA
EL
ELEC
ENCL
ENTR
EQ
EQUIP
EST
EXH
EXIST
EXP
EXT
CAP
CFM
CFS
CIRC
CJ
CHK
CKT
CL
CLOS
CLR
CMU
CND
COL
COMB
COMM
CONC
CONSTR
CONT
COR
CP
C.P.S.~
CPU
CR
CS
CT
CTR
CU
CU FT
CU YD
CAPACITY
CUBIC FEET PER MINUTE
CUBIC FEET PER SECOND
CIRCULAR
CONTRACTION JOINT
CHECK
CIRCUIT
CENTER LINE
CLOSURE
CLEAR
CONCRETE MASONRY UNIT
CONDUIT (FOR RACEWAY-ELEC. SHTS)
COLUMN
COMMON
COMMUNICATION
CONCRETE, CONCENTRIC
CONSTRUCTION
CONTINUE, CONTINUOUS
CHANGE ORDER REQUEST,
CONTRACTING OFFICER REPRESENTATIVE
CONTROL PANEL
CYCLES PER SECOND (HERTZ)
CENTRAL PROCESSING UNIT
CONTROL RELAY
CONTROL SWITCH
CURRENT TRANSFORMER
CENTER
COPPER
CUBIC FEET
CUBIC YARDS
- C -
INSIDE DIAMETER
INCHES
INFORMATION
INSULATION
INTERIOR
INPUT/OUTPUT
ID
IN
INFO
INSUL
INT
I/O
JUNCTION BOX
JUNCTION
JOIST
JOINT
JB
JCT
JST
JT
KEY, THOUSAND
THOUSAND POUND
KIPS PER SQUARE INCH
KILOVOLT
KILOVOLT AMPERE
KILOVOLT AMPERE REACTIVE
KILOWATT
KILOWATT HOUR
K
KIP
KSI
kV kVA kVAR kW kWh
PERSONAL COMPUTER, POINT OF CURVE
POUNDS PER CUBIC FOOT
PRODUCT DELIVERY TEAM
PERFORATED
POLYETHYLENE
PHASE
PROGRAMMABLE LOGICAL CONTROLLER
POUNDS PER LINEAR FOOT
PANEL
PARTS PER MILLION
PAIR
PREFABRICATE
PREFINISH
PROCESSING
PROJECT
POUNDS per SQUARE FOOT POUNDS per SQUARE INCH
POST SORT POOL DRAIN
PRE-SORT SUPPLY
POINT, POINT OF TANGENCY,
POTENTIAL (VOLTAGE) TRANSFORMER,
PRESSURE TRANSMITTER
POLYTETRAFLOURIDETHYLENE (TEFLON)
PUSH TO TEST
POLYVINYL CHLORIDE (PLASTIC)
POWER
PC
PCF
PDT
PERF
PE
PH
PLC
PLF
PNL
PPM
PR
PREFAB
PREFIN
PROC
PROJ
PSF
PSI
PSPD
PSS
PT
PTFE
PTT
PVC
PWR
TO BE DETERMINED
TOP ELEVATION
TECHNICAL
TELEPHONE
TEMPERATURE
TERMINAL
THICK, THICKNESS
TOP OF
TOP OF CONCRETE
TOP OF FOOTING
TOPOGRAPHY
TOP OF SLAB
TOP OF WALL
THERMOSTAT
TYPICAL
TBD
TE
TECH
TEL
TEMP
TERM
THK
TO
TOC
TOF
TOPO
TOS
TOW
TSTAT
TYP
A
AC
AC
ACI
AFCI
AGGR
AH
AI
AIC
AISC
AIR
ALM
ALT
AL,ALUM
AMP
ANSI
AO
APPROX
ARCH
ASME
ASPH
ASTM
AT
ATS
AUTO
AUX
AVG
AWG
AWS
L
AMMETER
ALTERNATING CURRENT
ASPHALT CONCRETE
AMERICAN CONCRETE INSTITUTE
ARC FAULT CIRCUIT INTERRUPTOR
AGGREGATE
AMPERE HOUR
ANALOG INPUT, ASPHALT INSTITUTE
AMPERE INTERRUPTING CAPACITY
AMERICAN INSTITUTE of STEEL
CONSTRUCTION
AMPERE INTERRUPTING RATING
ALARM
ALTERNATE
ALUMINUM
AMPERE
AMERICAN NATIONAL STANDARDS
INSTITUTE
ANALOG OUTPUT
APPROXIMATE
ARCHITECTURAL
AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
ASPHALT
AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AMPERE TRIP
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AUXILIARY
AVERAGE
AMERICAN WIRE GAUGE
AMERICAN WELDING SOCIETY,
ATTRACTION WATER SUPPLY
ANGLE (STRUCTURAL SHAPE)
BCG
BD
BDRY
BK,BRK
BLDG
BM
BMP
BOT
BRCG
BRDG
BRG
BRKT
B/B
BTU
BTUH
BARE COPPER GROUND
BOARD
BOUNDARY
BRAKE
BUILDING
BEAM, BENCH MARK
BEST MANAGEMENT PRACTICE
BOTTOM
BRACING
BRIDGING
BEARING
BRACKET
BACK TO BACK
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
UGND
UL
UNO
UPS
U/S
UTIL
UNDERGROUND
UNDERWRITERS LABORATORIES
UNLESS NOTED OTHERWISE
UNINTERRUPTIBLE POWER SYSTEM
UPSTREAM
UTILITY
- V -
- W -
XFMR
XMTR
TRANSFORMER
TRANSMITTER
- X -
- Y -
YARDYD
- Z -
LIMIT SWITCH
POSITION TRANSMITTER
ZS
ZT
VERTICAL, VOLT
VERTICAL
VARIABLE FREQUENCY DRIVE
VOLTMETER
VOLUME
V
VERT
VFD
VM
VOL
WATT, WEST, WIRE
WITH
WITHOUT
WET BULB
WATTHOUR METER
WATERLINE
WATERTIGHT, WEIGHT
W W/ W/O
WB
WHM
WL
WT
- F -
- G -
- H -
FAHRENHEIT, FUSE
FOOTCANDLE
FEEDER
FOUNDATION
FIGURE
FINISH
FINISH GRADE
FIXTURE
FLEXIBLE
FLANGE, FLOORING
FLOOR
FLUORESCENT
FIBER OPTIC
FIREPROOF, FIRE PROTECTION
FEET PER MINUTE
FULL SIZE
FEET
FOOTING
FUSE
F
FC
FDR
FDTN
FIG
FIN
FIN GR
FIX
FLEX
FLG
FLR
FLUOR
F/O
FP
FPM
FS
FT
FTG
FU
GAGE or GAUGE
GALLON
GALVANIZED
GENERAL, GENERATOR
GROUND FAULT CIRCUIT INTERRUPTOR
GROUND FAULT INTERRUPTOR
GOVERNMENT
GOVERNMENT FURNISHED EQUIPMENT
GOVERNMENT INSTALLED
GROUND
GALLONS PER MINUTE
GOVERNMENT QUALITY ASSURANCE
REPRESENTATIVE
GRADE, GROSS
GALVANIZED RIGID STEEL CONDUIT
GA
GAL
GALV
GEN
GFCI
GFI
GOVT
GFE
GOVT INSTL
G,GND
GPM
GQAR
GR
GRS
HIGH DENSITY POLYETHYLENE
HEADER
HUMAN MACHINE INTERFACE
HORIZONTAL
HIGH PRESSURE, HORSEPOWER
HOUR
HEIGHT
HERTZ
HDPE
HDR
HMI
HORIZ
HP
HR
HT
Hz
- L -
- M -
N
NA
NAT
NC
NEC
NEMA
NEUT
NF
NFPA
NIC
NO
NOM
NPL
NPS
NPT
NTS
NORTH
NOT APPLICABLE
NATURAL
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUTRAL
NEAR FACE
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NUMBER, NORMALLY OPEN
NOMINAL
NAMEPLATE
NOMINAL PIPE SIZE
NATIONAL PIPE THREAD
NOT TO SCALE
- O -
- N -
POUNDS
LINEAR FEET
LENGTH OR LONG
LINEAR
LUMEN
LEFT, LEVEL TRANSMITTER, LIGHT
LBS
LF
LG
LIN
LM
LT
MIXED AIR
MACHINE
MAINTENANCE
MATERIAL
MAXIMUM
MACHINE BOLT
MOTOR CONTROL CENTER
MECHANICAL
MANUFACTURING
MANUFACTURER
MOTOR GENERATOR
MANAGEMENT
MANHOLE
MINIMUM
MARK
MOTOR
MECHANICALLY STABLILIZED EARTH
MEAN SEA LEVEL
METAL
MA
MACH
MAINT
MATL
MAX
MB
MCC
MECH
MFG
MFR
MG
MGT
MH
MIN
MK
MOT
MSE
MSL
MTL
OVER ALL LENGTH
ON CENTER
ON CENTER EACH WAY
OUTSIDE DIAMETER
OUTSIDE FACE
OFFICE
OBSCURE GLASS
OPENING
OPPOSITE
OPERATIONS
OUT TO OUT
OAL
OC
OCEW
OD
OF
OFF
OGL
OPNG
OPP
OPS
O/O, O TO O
- S -
- R -
- Q -
REMOTE CONTROL
RECEIVER
ROAD, ROOF DRAIN
REFERENCE
REINFORCE OR REINFORCEMENT
REQUIRED
REVISION
ROOFING
ROUGH
RIGID GALVANIZED STEEL CONDUIT
RELATIVE HUMIDITY, RIGHT HAND,
ROUND HEAD
ROOM
ROUND
REVOLUTIONS PER MINUTE
RIGHT
RC
RCVR
RD
REF
REG
REQD
REV
RFG
RGH
RGSC
RH
RM
RND
RPM
RT
SOUTH
SUPERVISORY CONTROL AND
DATA ACQUISITION
SCHEDULE
SECTION
SEQUENCE
SQUARE FOOT (FEET), SUPPLY FAN
SHEET
SIMILAR
SERIAL NUMBER, SOLID NEUTRAL
SOLENOID
SPECIAL
SPECIFICATION
SPEAKER
SQUARE
STAINLESS STEEL
STATION
STANDARD
STEEL
STORAGE
STRUCTURAL
STAIRWAY
SUBFLOOR
SUSPEND
SWITCH
SWITCHBOARD
SYMBOL
SYMMETRICAL
S
SCADA
SCHED
SECT
SEQ
SF
SHT
SIM
S/N
SOL
SPCL
SPEC
SPKR
SQ
SST
STA
STD
STL
STOR
STRUCT
STWY
SUB FL
SUSP
SW
SWBD
SYM
SYMM
NOTES:
1. ALL ABBREVIATIONS TO BE
VALIDATED WITH THE UNIFORM
DRAWING SYSTEM TERMS AND
ABBREVIATIONS MODULE OF
THE UNITED STATES NATIONAL
CADD STANDARD LATEST
VERSION OR OTHER GENERALLY
ACCEPTED ENGINEERING OR
APPROVED PUBLICATION.
2. TERMS WITH FIVE LETTERS OR
FEWER SHOULD NOT BE
ABBREVIATED.
3. LIST ALL TRADE ASSOCIATIONS
ACRONYMS, SUCH AS UL, ASTM,
AISC, etc., IF THE ORGANIZATION
PUBLISHES STANDARDS
REFERENCE ON THE DRAWINGS.
4. AVOID THE USE OF
ABBREVIATIONS WITH MORE
THAN ONE MEANING UNLESS
THE CONTEXT OR THE LOCATION
WITHIN THE DRAWING SET MAKE
THE INTENDED MEANING
OBVIOUS.
5. ABBREVIATIONS REPRESENTING
PROFESSIONAL LICENSES,
CERTIFICATIONS, OR
MEMBERSHIPS ASSOCIATED
WITH A PERSON'S ARE NOT
INCLUDE IN THE ABBREVIATION
LIST.
6. IF ANY DOUBT OR CONFUSION
EXISTS ABOUT THE MEANING OF
AN ABBREVIATION, DO NOT USE
THE ABBREVIATION. INSTEAD
SPELL OUT TERM.
B
C
D
1 2 3 4 5
A
B
C
D
54321
ANGULAR
GENERAL
LINEAR FRACTIONAL
8"
0.002"
0 DECIMAL PLACES
1 DECIMAL PLACE
LINEAR DECIMAL
0.010" 0.030"
TOLERANCES UNLESS OTHERWISE SPECIFIED
1 DECIMAL PLACE
0.5 0.1
2 DECIMAL PLACES
3 DECIMAL PLACES
SAWING, FLAME CUTTING,
SHEARING, AND BREAKING
STRUCTURAL SHAPES AND
WELDING
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
M-001
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
M
EC
H
AN
IC
AL
G
EN
ER
AL
N O
TE
LI
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
TC
R
/3
0/
BR
IA
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
AN
M
AR
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
MECHANICAL GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
MECHANICAL ABBREVIATIONS
APPROX
DET
DIA
ELEV
FT.
GALV.
ID.
IN.
MAX.
MIN.
MECH.
NOM
NTS
OD.
PL
PN
RAD.
STD
SYM
TYP
UNO
= APPROXIMATELY
= CENTERLINE
= DETAIL
= DIAMETER
= ELEVATION
= FEET
= GALVANIZED
= INNER DIAMETER
= INCHES
= MAXIMUM
= MINIMUM
= MECHANICAL
= NOMINAL
= NOT TO SCALE
= OUTER DIAMETER
= PLATE
= PART NUMBER
= RADIUS
= STANDARD
= SYMMETRIC
= TYPICAL
= UNLESS NOTED OTHERWISE
INFORMATION, TOLERANCES, AND NOTES ON THIS SHEET APPLY TO ALL MECH. DRAWINGS, UNLESS NOTED
OTHERWISE.
UNLESS OTHERWISE NOTED, USE CARBON OR ALLOY STEEL MECHANICAL FASTENERS, HOT-DIP GALVANIZED IN
ACCORDANCE WITH ASTM F2329.
NOMINAL THREAD CLASS FOR INTERNAL AND EXTERNAL THREADS IS UNC 2A/2B. WHEN THREADS ARE CUT FOR USE
WITH HOT-DIP GALVANIZED FASTENERS, ADJUST TOLERANCES PER ASTM A563.
PERFORM WELDING OF CARBON AND STAINLESS STEEL IN ACCORDANCE WITH THE SPECIFICATIONS.
WELDING OF ALUMINUM SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.2
MACHINE KEYWAYS IN ACCORDANCE WITH ASME B17.1. SUPPLY KEYS FOR ALL ASSEMBLIES.
KEYS MUST CONFORM TO REQUIREMENTS INDICATED ON CONTRACT DRAWINGS.
125 MICROINCH SURFACE TEXTURE ON ALL MACHINED SURFACES, UNLESS SHOWN OTHERWISE. SURFACE TEXTURE
PER ASME B46.1.
NOMINAL DIMENSIONS SHOWN ARE BASED ON SPECIFIED EQUIPMENT. ADJUSTMENTS MAY BE REQUIRED DEPENDING ON EQUIPMENT SUPPLIED AND FIELD VERIFICATION. SUBMIT PROPOSED DIMENSION CHANGES FOR APPROVAL ON THE
DETAIL DRAWINGS.
ALL LINEAR UNITS ARE FEET AND INCHES OR INCHES AND ALL ANGULAR UNITS ARE DEGREES, UNLESS SHOWN
OTHERWISE.
BREAK CORNERS AND EDGES, UNLESS SHOWN OTHERWISE.
AT FABRICATION, ASSIGN ALL PARTS A CONTRACTOR-DESIGNATED PART NUMBER MARK BY EMBOSSING OR ETCHING. SHOP ASSEMBLE ALL FABRICATED PARTS AND CHECK FOR PROPER FIT AND TOLERANCES. MATCH MARK
ALL PARTS FOR REFERENCE DURING ASSEMBLY.
ALL PARTS ESTIMATED TO WEIGH GREATER THAN 50 POUNDS-FORCE SHALL BE MANUFACTURED WITH PROVISIONS FOR LIFTING, SUCH AS TAPPED HOLES, THRU HOLES FOR SHACKLES, OR PAD EYES. IF PROVISIONS OR FEATURES DO NOT EXIST ON CONTRACT DRAWINGS, CREATE PROVISIONS ON SHOP DRAWINGS AND INDICATE THAT THE
FEATURE IS FOR LIFTING OR HANDLING.
PERFORM PAINTING OF MECHANICAL COMPONENTS IN ACCORDANCE WITH 09 97 03.00 PAINTING: MECHANICAL
EQUIPMENT UNLESS OTHERWISE SHOWN.
SEE SPECIFICATIONS FOR ADDITIONAL EQUIPMENT REQUIREMENTS. DRAWING PART NUMBERS MAY NOT REFLECT
EVERY SALIENT FEATURE.
JR
L1
.0
_M -0
XX
X.
dw g
C
D
1 2 3 4 5
A
B
C
D
54321
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
MD101
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
M
EC
H
AN
IC
AL
D
EM
O
LI
TI
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
TC
R
/3
0/
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
LEFT
TRANSITION
MONOLITH PIER 1 PIER 2 PIER 3 PIER 4
RIGHT
TRANSITION
MONOLITH
FL
O
W
DEMO EXISTING COUPLING GUIDE HANDLES. TYP 6
DEMO EXISTING LIMIT SWITCHES, TYP 5
SCALE:
GENERAL DEMOLITION PLAN VIEW
NOT TO SCALE
GATE 1 GATE 2 GATE 3 GATE 4
GATE 5
SCALE:
LIMIT SWITCH DEMOLITION
NOT TO SCALE
SCALE:
COUPLING HANDLE DEMOLITION
NOT TO SCALE
DEMO GRATING IF NECESSARY TO ALLOW
COUPLING GUIDE HANDLE LEGS TO ATTACH
TO GIRDER. SEE M-101 FOR DETAILS
NOTES:
1. SEE M-001 FOR MECHANICAL GENERAL NOTES.
2. CROSS HATCHED AREAS INDICATE DEMOLITION.
EXISTING RECORD DRAWINGS
REFERENCED:
15168-1/SM-1
DEMO ONLY EXISTING COUPLING GUIDE HANDLE AND
BOLTS FROM COUPLING ASSEMBLY. REFER TO MC-500 FOR
NEW COUPLING GUIDE HANDLE.
DEMO LIMIT SWITCH, 80 TOOTH SPROCKET
AND CHAIN ROLLER.
KEEP LIMIT SWITCH BASE PLATE.
NEW LIMIT SWITCH PEDESTAL SHALL
BE WELDED TO EXISTING BASE PLATE.
SEE M-102 FOR DETAILS.
SCALE:
LIMIT SWITCH DEMOLITION AND BASE PLATE VIEW
NOT TO SCALE
DEMO EXISTING LIMIT SWITCH
JR
L1
.0
_M D
-1
XX
X.
C
D
1 2 3 4 5
A
B
C
D
54321
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
M-101
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
C O
U
PL
IN
G
G U
ID
E
SU
PP
O R
T
AS
SE
M
BL
Y
AN
D
IN
ST
AL
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
TC
R
/3
0/
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
6"3"
SCALE: 6"= 1'-0"
2"1"0
SCALE:
NEW COUPLING GUIDE ASSEMBLY - ISOMETRIC VIEW
NTS
EXISTING
MOTOR
EXISTING
MOTOR TO
WORMGEAR
COUPLING
EXISTING
WORM GEAR
EXISTING PARALLEL GEAR
REDUCER COVER
NEW COUPLING GUIDE ASSEMBLY
TYP 1 PER CUT-OUT COUPLING
EXISTING
GRATING
PARALLEL GEARBOX REDUCER COVER
(NOT TO SCALE)
4"
3/16
4"
3/8" THICK A-36
CARBON STEEL PLATE
STRUCTURAL STEEL
GIRDER
1/4"SEE NOTE 4
MODIFY PORTION OF EXISTING
GRATING FOR SUFFICENT ROOM
TO WELD COUPLING GUIDE SUPPORT LEG
TO GIRDER.
NOTES:
1. SEE M-001 FOR MECHANICAL GENERAL NOTES.
2. INSTALL COUPLING HANDLE FIRST, PRIOR TO INSTALLING COUPLING GUIDE SUPPORT. INSTALL COUPLING GUIDE SUPPORT AROUND HANDLE TO ENSURE ACCEPTABLE INTERFACE. REFER TO SPECIFICATION SECTION 35 01 41.00 10.
3. FIELD VERIFY CARBON STEEL PLATE REQUIRED WIDTH AND HEIGHT. PROVIDE SHOP DRAWINGS OF FINAL COUPLING SUPPORT ASSEMBLY FOR GOVERNMENT APPROVAL IN ACCORDANCE WITH SPECIFICATION SECTION 35 01 41.00 10. PLATE WIDTH AND HEIGHT SHALL ALLOW SUFFICIENT ROOM FOR COUPLING GUIDE SUPPORT TO FIELD DRILL THROUGH PLATE.
4. FIELD VERIFY REQUIRED HEIGHT OF L-BARS FOR PROPER INTERFACE WITH COUPLING GUIDE HANDLE. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO INSTALL IN ACCORDANCE WITH SPECIFCATION SECTION 35 01 41.00 10.
DIMENSIONS MAY VARY PER COUPLER.
5. PAINT STEEL AFTER FIELD WELDING IN ACCORDANCE WITH SPECIFICATION SECTION 09 97 03.
6. AFTER COUPLING SUPPORT INSTALLATION, FIELD DRILL THRU HOLES FOR GUIDE PIN. WHEN GUIDE PIN IS IN USE, ONE PIN SHALL BE IN SLOT ENFORCING HANDLE TO REMAIN IN "COUPING POSITION". WHEN COUPLING IS DISENGAGED, PIN SHALL BE PLACED IN THE DISENGAGED SLOT. PROVIDE A LABEL TO INFORM OPERATOR WHEN COUPLER IS ENGAGED/DISENGAGED. PROVIDE A STAINLESS STEEL CHAIN LINK LANYARD SECURING BOLT PIN TO COUPLING GUIDE. USE MCMASTER-CARR PART NO. 92692A551 OR APPROVED EQUAL. SUBMIT SHOP DRAWINGS OF BOLT LOCATION AND LANYARD
CONNECTION FOR APPROVAL PRIOR TO LANYARD INSTALL.
7. BREAK ALL CORNERS AND EDGES.
NEW COUPLING
ENGAGEMENT HANDLE
SEE NOTE 2
ADD RUBBER SLEEVE
MCMASTER-CARR
PART NO. 9692K62
OR APPROVED
EQUAL
FASTEN NEW HANDLE TO EXISTING
COUPLER ENGAGEMENT ASSEMBLY.
USE SAME BOLT SIZE AS ORIGINAL
AND EXISTING BOLT LOCATIONS.
" N
O M
. S
EE
M -5
SCALE:
COUPLING GUIDE INSTALLATION
6" = 1'-0"
DETAIL
SCALE:
- NTS
STEEL BODY PADLOCK
MCMASTER-CARR PART NO.
1176A18 OR APPROVED EQUAL
ALL PADLOCK KEYS MUST BE
KEYED ALIKE.
BRONZE LOCKING PIN.
STAINLESS STEEL LANYARD
NOT SHOWN FOR CLARITY.
SEE SHEET M-501 FOR DETAILS.
ENGAGED POSITION SHOWN.
DETAIL
SCALE:
- NTS
ADD LABEL TO INFORM OPERATOR WHEN
COUPLER IS ENGAGED VS. DISENGAGED.
LABEL SHALL BE UV AND WEATHER RESISTANT.
SEE NOTE 6
STEEL BODY PADLOCKBRONZE GUIDE PIN
EXISTING GRATING
THRU BOLT HOLE FOR WHEN COUPLER
IS DISENGAGED. SEE NOTE 6.
L BAR
SEE M-501
FOR DETAILS
4" NOM
SEE NOTE 3
4" N
O M
SE
E
N O
TE
SEE NOTE 5
COUPLING GUIDE
THRU BOLT 1/2" BOLT GALVANIZED BOLT
WITH CORRESPONDING NUT AND WASHER
TYP 2. ENSURE BOLTS MEET REQUIRED SPACING
IN ACCORDANCE WITH STEEL CONSTRUCTION
MANUAL 14TH EDITION. SHIM IF NECESSARY.
JR
L1
.0
_M -1
XX
X.
C
D
1 2 3 4 5
A
B
C
D
54321
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
M-102
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
LI
M
IT
S
W
IT
C H
A
SS
EM
BL
Y
AN
D
IN
ST
AL
L
ZX
C
LI
N
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
TC
R
/3
0/
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
3"
SCALE: 3"= 1'-0"
6"0 12"
SCALE:
LIMIT SWITCH ASSEMBLY - ISOMETRIC VIEW
NOT TO SCALE
3/16"
TYP
SEE NOTE 2.
BILL OF MATERIALS
PART NO. COMPONENT DESCRIPTION
SH1 ROTARY LIMIT SWITCH ROTARY LIMIT SWITCH, 4.1 USABLE REVOLUTIONS, BASIS OF DESIGN, STROMAG 51 SERIES
SH2 LIMIT SWITCH PEDESTAL SEE M-502
SH3 LIMIT SWITCH COUPLING RULAND BEAM COUPLING, PRODUCT NUMBER PCMR22-8-8-SS
SH4 LIMIT SWITCH DRIVE SHAFT SEE M-502
SH5 SHAFT BEARING - NON-EXPANSION
DODGE, D-LOK BALL BEARINGS, DL NORMAL DUTY PILLOW BLOCKS2
BOLT, NON-EXPANSION TYPE.BASIS OF DESIGN: DODGE PN
P2B-DLH-100-E
SH6 SHAFT BEARING - EXPANSION DODGE, D-LOK BALL BEARINGS, DL NORMAL DUTY PILLOW BLOCKS2
BOLT, EXPANSION TYPE.BASIS OF DESIGN: DODGE PN P2B-DLH-100
SH7 LIMIT SWITCH SPROCKET
CARBON STEEL, 15 TOOTH SPROCKET, 3/4" PITCH WITH
CORRESPONDING QP BUSHING. BASIS OF DESIGN IS MARTIN STEEL
SPROCKET, NO.60, TYPE QD, CATALOG NO. 60SH15. WITH
CORRESPONDING SH BUSHING
SH8 SPROCKET ROLLER CHAIN SINGLE STRAND CARBON STEEL, ANSI NO. 60, 3/4" PITCH
SH9 LIMIT SWITCH COVER SEE M-502
SH1
SH2
SH3
SH5
SH6
SH4
SH7
SH8
LIMIT
SWITCH
LIMIT SWITCH ASSEMBLY PLAN VIEW
3" = 1'-0"
EXISTING DRUM
SHAFT BEARING
EXISTING DRUM
SHAFT SPROCKET
EXISTING
PARALLEL
REDUCER
NOTE:
CHAIN ROLLERS AND ADDITIONAL
GATE HOIST EQUIPMENT HAVE
BEEN REMOVED FOR CLARITY. REFER
TO REFERENCE DRAWINGS FOR SPILLWAY
GATE HOIST MACHINERY LAYOUT
SEE NOTE 2
NOTES:
1. SEE M-001 FOR MECHANICAL GENERAL NOTES.
2. FIELD VERIFY PEDESTAL LOCATION WITH RESPECT TO EXISTING HOIST EQUIPMENT. PROVIDE SHOP DRAWING OF NEW LIMIT PEDESTAL LOCATION FOR APPROVAL PRIOR TO INSTALLATION. DEMOLITION OF A PORTION OF GRATING IS ACCEPTABLE IF NEW
PEDESTAL FOOTPRINT EXCEEDS ORIGINAL PEDESTAL FOOTPRINT.
3. PROVIDE ALL KEYS, BOLTS, NUTS AND WASHERS NECESSARY TO ASSEMBLE THE BEARINGS, LIMIT SWITCH DRIVE
SHAFT AND LIMIT SWITCH.
4. PROVIDE A CONTRACTOR DESIGNED COVER THAT GOES OVER THE SPROCKETS AND ROLLER CHAIN. THE COVER SHALL BE MADE OF STEEL AND PAINTED IN ACCORDANCE TO SPECIFICATION SECTION 09 97 03.00 25 AND WITH A HANDLE FOR EASY ACCESS. THE SPROCKET COVER SHALL HAVE A MEANS OF ATTACHMENT TO EITHER THE DRUM SHAFT BEARING OR LIMIT SWITCH PEDESTAL TO
PREVENT UNWANTED MOVEMENT.
5. SHIM BETWEEN THE BEARINGS AND THE BEARING BLOCK FOR PROPER ALIGNMENT WITH LIMIT SWITCH DRIVE SHAFT.
6. FIELD VERIFY THE REQUIRED OFFSET FOR EACH MECHANICAL COMPONENT IN THE LIMIT SWITCH ASSEMBLY. PROVIDE SHOP
DRAWINGS DETAILING OFFSET OF EACH MECHANICAL COMPONENT PRIOR TO INSTALLATION.
7. PERFORM ALL WELDS IN ACCORDANCE WITH AWS D1.1
EXISTING DRUM SHAFT
BEARING
EXISTING PARALLEL
REDUCER
SEE NOTE 3
NOTE: LIMIT SWITCH COVER AND ADDITIONAL HOIST EQUIPMENT
REMOVED FOR CLARITY.
SEE NOTE 5
THESE COMPONENTS ARE BASIS OF DESIGN.
PROVIDE THESE COMPONENTS OR APPROVED EQUAL
EXISTING PEDESTAL BASE PLATE
MATCH DRILL THRU
BEARING PEDESTAL
1/2"-13 UNC BOLT
WITH CORRESPONDING
NUT AND WASHER
TYP 5
SH9
ELECTRICAL PANEL
REMOVED FOR CLARITY
42"x30"x10" ELECTRICAL PANEL
1" CONDUIT
TO ELECTRICAL PANEL.
RUN CONDUIT BENEATH GRATING
SEE ELECTRICAL SHEETS
FOR DETAILS
8"
N O
M
SE
E N
O
TE
FLEXIBLE CONDUIT
FLEXIBLE 1"
CONDUIT
SEE ELECTRICAL
DRAWINGS
FOR DETAILS
SH7
3/16"
TYP
SEE NOTE 2
THRU DRILL
STEEL FASTENER
USE BEARING MFR
RECOMENDED BOLT
DIA. TYP 4
JR
L1
.0
_M -1
XX
X.
dw g
SEE NOTE 5
SEE NOTE 2
C
D
1 2 3 4 5
A
B
C
D
54321
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
M-501
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
C O
U
PL
IN
G
G U
ID
E
C O
M
PO
N
EN
T D
ET
AI
LS
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
M
KH
/3
0/
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
SCALE: 6"= 1'-0"
2" 3"1" 6"
1"
SCALE: 12"= 1'-0"
2" 3"0
SCALE:
COUPLING
SUPPORT RIGHT LEG
MATERIAL:
PER:
NO. REQD:
6" = 1'-0"
CARBON STEEL
ASTM A36
1 PER COUPLING SUPPORT ASSEMBLY
COUPLING
SUPPORT LEFT LEG
MATERIAL:
PER:
NO. REQD:
6" = 1'-0"
CARBON STEEL
COUPLING HANDLE
MATERIAL:
PER:
NO. REQD:
6" = 1'-0"
CARBON STEEL
8" SEE NOTE 4
2"
1"
2"
GUIDE PIN
PER:
NO. REQD:
12" = 1'-0"
936 BEARING BRONZE
MACHINE FROM ROUND BAR STOCK
Ø
" T H
R U
8"
Ø " T
H R
U
3/16" TYP
2" 51
2"
3"
" N
O M
. S
EE
N O
TE
" N
O M
. S
EE
N O
TE
NOTES:
1. SEE M-001 FOR GENERAL MECHANICAL NOTES.
2. BREAK ALL CORNERS AND EDGES.
3. FIELD VERIFY NECESSARY HEIGHT PRIOR TO FABRICATION. DRAWINGS SHOWN ARE NOMINAL AND MAY CHANGED FROM FIELD VERIFICATION. SHOP. DRAWINGS MUST BE APPROVED PRIOR TO FABRICATION. COUPLING SUPPORT LEGS SHALL HAVE PROPER
OFF-SET AND HEIGHT TO ALLOW INTERFACE WITH COUPLING GUIDE HANDLE.
4. FIELD VERIFY DISTANCE FOR COUPLING SUPPORT GUIDE LEGS. SHOP DRAWINGS MUST BE APPROVED PRIOR TO FABRICATION.
DISTANCE BETWEEN LEGS SHALL ALLOW FOR A BOLTED CONNECTION TO THE WORM GEAR PEDESTAL PLATE AND WELDMENT
TO THE STEEL GIRDER.
SCALE:
COUPLING SUPPORT ASSEMBLY
6"=1'-0"
COUPLING SUPPORT RIGHT LEG
COUPLING
SUPPORT
LEFT
LEG
2" NOM. SEE NOTE 4
4"
4"
4"
2"
5"
3/16" 3/16"
AISC L 2 X 2 X 5/16
TYP 2 PER COUPLING
SUPPORT ASSEMBLY
4" TYP 1
4" TYP
8"
Ø
45° CHAMFER
5"
7"
2"
2"
2" NOM.
8"
8" SEE NOTE 3
1.25"
8" N
O M
14(
Ø
" N
M SYM
SYM
JR
L1
.0
_M -5
XX
X.
C
D
1 2 3 4 5
A
B
C
D
54321
D
ES
IG
N
E D
B Y:
D
AT
E:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
A
TI
O
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
PL
O
T
SC
AL
E:
PL
O
T D
AT
E
SI
ZE
FI
LE
N
AM
E:
US Army Corps of Engineers
BALTIMORE DISTRICT
SHEET
IDENTIFICATION
M-502
JE
N
N
IN
G S
R
AN
D O
LP
H
L
AK
E
SP
IL
LW
AY
EL
EC
TR
IC
AL
U
PG
R
AD
E
LI
M
IT
S
W
IT
C H
C O
VE
R
PE
D
ES
TA
L
AN
D S
H
AF
T D
ET
AI
LS
LI
N
D S
EY
A
R O
TH
G 2E
C D
LA
R
G 2E
C D
M
KH
/3
0/
N
P . B
EL
L, P .E
1:
AN
S
I D
BA
LT
IM
O
R E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
BA
LT
IM
O
R E, M
AR
YL
K
D
ES
C R
IP
TI
O N
AP
PR
D
A
TE
PO
R
TL
AN
D , O
R
EG
O N
PO
R
TL
AN
D D
IS
TR
IC
T
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
IN
G N
O
A
A
B
B
0 2"
SCALE: 12"= 1'-0"
3"1" 12"
SCALE: 3"= 1'-0"
6"3"0
CARBON STEEL WELD
ON PIANO HINGE
1/2" MIN. KNUCKLE LG.
WELD TO BASE PLATE
AND LID
8" TYP
4"
2"
4"
1/8"
1/8"TYP
3/16" PLATE
BASE SUPPORT
PER:
NO. REQD:
3" = 1'-0"
CARBON STEEL
1 PER LIMIT SWITCH COVER ASSEMBLY
SEE NOTE 3
18" 73 4"
4"
R1"
R3 8"
LIMIT SWITCH COVER LID
PER:
NO. REQD:
3" = 1'-0"
CARBON STEEL
1 PER LIMIT SWITCH COVER ASSEMBLY
NOTES:
1. SEE M-001 FOR GENERAL MECHANICAL NOTES.
2. BREAK ALL CORNERS AND EDGES.
3. PAINT IN ACCORDANCE WITH SPECIFICATIONS SECTION 09 97 03.
4. NOMINAL SHAFT DIMENSION SHOWN. COORDINATE FINAL TOLERANCE WITH BEARING
AND SPROCKET MANUFACTURER. SELECTED TOLERANCES SHALL BE SHOWN ON
CONTRACTOR'S SUBMITTED DRAWINGS. INSTALL BEARINGS PER MANUFACTURERS
RECOMMENDATION.
5. NOMINAL DIMENSION SHOWN. COORDINATE FINAL TOLERANCE WITH COUPLING
MANUFACTURER. SELECTED TOLERANCES SHALL BE SHOWN ON CONTRACTOR'S
SUBMITTED DRAWINGS.
BASE
SUPPORT
LIMIT SWITCH COVER LID
SCALE:
LIMIT SWITCH COVER ASSEMBLY
3" = 1'-0"
4"
BASE
SUPPORT
LIMIT SWITCH COVER LID
LIMIT SWITCH COVER LID
SEE NOTE 3
1" NOM
SEE NOTE 4
2"
11"
COORDINATE KEYWAY SIZING WITH
SPROCKET MFR PER ASME B17.1
SEE NOTE 4
LIMIT SWITCH DRIVE SHAFT
PER:
NO. REQD:
12" = 1'-0"
CARBON STEEL
ASTM A108
1 PER LIMIT SWITCH
8mm NOM.
SEE NOTE 5
COORDINATE KEYWAY SIZING WITH
COUPLING MFR PER ASME B17.1
45° CHAMFER45° CHAMFER
1/2" X 10.5" FLANGE PL.
1/2" WEB PL.
1" TYP
10( ")
20"
1/2" X 4.5" PL.
8"
4"BEARING
BLOCK
1.5" x 5.5" x 0.75" CARBON STEEL BLOCK
MAT'L: CARBON STEEL A572 GRADE 50
1/4" TYP 2
LIMIT SWITCH PEDESTAL
PER:
NO. REQD:
3" = 1'-0"
CARBON STEEL
1 PER LIMIT SWITCH
1/4"
TYP PER
FLANGE
2" TYP
2" T
YP
2" NOM.
8"
1/8"TYP
2" THRU
TYP 5
R11 4( ")
2"
18"
4"
4"
8"
1"
1/4"
1/4" TYP
SECTION
SCALE:
- 3"=1'-0"
2"
2"
1"
1/8" 1/8"
3/16" PLATE
SECTION
SCALE:
- 3"=1'-0"
N O
M
4"
12"
WELD ON PULL HANDLE
MCMASTER-CARR PN 1650A1
OR APPROVED EQUAL
3/16" PLATE3/16" PLATE
1/4"
1/8"
JR
L1
.0
_M -5
XX
X.
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
FUSE
OVERLOAD RELAY
VOLTAGE OR CONTROL TRANSFORMER
DISCONNECT SWITCH
MOLDED-CASE CIRCUIT BREAKER, NUMBER
INDICATES TRIP RATING IN AMPERES.
2P INDICATES 2-POLE
3P INDICATES 3-POLE
IN DE-ENERGIZED POSITION
OR WHEN QUANTITIES TO
WHICH THEY RESPOND ARE
OF THE LOWEST VALUE
CONNECTION TO GROUND BUS
INTERLOCK (MECHANICAL OR KEY)
480V RECEPTACLE
NON-FUSED HP RATED DISCONNECT SWITCH
TRANSIENT SUPPRESSOR
NEW CONTROL CIRCUIT IDENTIFICATION
PER SCHEDULE
NEW POWER CIRCUIT IDENTIFICATION
PER SCHEDULE
INTERLOCK (ELECTRICAL)
N.O. PUSH BUTTON
N.C. PUSH BUTTON
INTEGRAL MOTOR STARTER
MANUAL MOTOR STARTER
COMBINATION MOTOR STARTER
(NUMBER INDICATES NEMA SIZE RATING)
FUSED HP RATED DISCONNECT SWITCH
JUNCTION BOX
HOME RUN TO PANELBOARD. ARROWS
INDICATE NUMBER OF CKTS, LETTERS
IDENTIFY PANEL, NUMBER(S) AT ARROW
IDENTIFIES CKTS. EXAMPLE: CKT 1 AND 3
TO PANEL LP.
CONDUIT CAPPED BELOW FIN. GRADE
GROUND INSERT IN FLOOR
EMBEDDED GROUND CONDUCTOR
(SIZE AS INDICATED).
LP:1,3
CONDUIT EXPOSED
CONDUIT EMBEDDED IN FLOOR OR WALL
CONDUIT TURNING TOWARD OBSERVER.
CONDUIT TURNING AWAY FROM OBSERVER.
MASTER CONTROL SWITCH
ELECTRICALLY OPERATED VALVE (SOLENOID)
POSITION SWITCH
AC CONTACTOR
MANUAL TRANSFER DEVICE
INSTANTANEOUS OVERCURRENT
OR RATE-OF-RISE RELAY
NUMBER OR LETTERS INDICATE
DEVICE FUNCTION AS NOTED.
SUFFIX X INDICATES ASSOCIATED
AUXILIARY RELAY.
SUFFIX USED FOR IDENTIFICATION.
SUFFIX Z INDICATES OPERATED
BY BELL ALARM CONTACT.
GRAPHIC SYMBOLS (CONT.)GRAPHIC SYMBOLS PANEL WIRING (CONT.) CONTROL ABBREVIATIONS
CONDUIT AND GROUNDING
LOCK
FISH RELATED
NON-OVERFLOW DAMD
F
L -
1. SWITCHBOARDS AND SWITCHGEAR
480V SWITCHGEAR (NAV LOCK)
480V SWITCHBOARD (MAIN UNITS)
480V SWITCHBOARD (FISHWATER UNITS)
13.8kV SWITCHGEAR (STATION SERVICE)
SUA
SU
LCQ
SJ
2. LOAD CENTERS
480V (POWERHOUSE)
480V (DAM LIGHTING)
SQ
FCQ
DQ
DCR1
CQ
480V (NON-OVERFLOW DAM)
480V SUBSTATION (POWERHOUSE)
3. APPARATUS
REMOTE PLC INPUT/OUTPUT RACK
CURRENT TRANSFORMER
BATTERY
MOTOR CONTROL CENTER
TRANSFORMER (LIGHTING)
BREAKER (ADD VOLTAGE LETTER)
DISC. SWITCH (ADD VOLTAGE LETTER)Z
X
TR
T
MCC
M
L
IOR
CT
B
A. TERMINAL EQUIPMENT
B. MODIFYING TERMS FOR TERMINAL EQUIPMENT
LIGHTING
MOTOR
TRANSFORMER (POWER)
J
P
Q
R
N NEUTRAL (i.e. GN1,TN1)
120/240 (120/208)
480V
5kV
13.8kV r q p j d c
2. SERVICE CODE OR VOLTAGE CLASS
- CONTROL CIRCUITS
0-48V AC/DC
POWER CIRCUIT, 13.8kVAC
POWER CIRCUIT, 4160VAC
POWER CIRCUIT, 480VAC
SPARE CONDUIT
tn s -
LOCAL AREA NETWORK (LAN) CIRCUITS
tt -tv
T1
DEDICATED T1 CIRCUITS
1. ELECTRICAL CIRCUITS AND CONDUITS ARE
IDENTIFIED AS FOLLOWS:
A. BETWEEN MAJOR ITEMS OF EQUIPMENT,
A THREE PART NUMBER IS USED.
B. A TWO-PART NUMBER IS USED FOR MOST
LIGHTING AND SOME POWER DISTRIBUTION
CIRCUITS; I.E., THE END OF RUN IS OMITTED.
C. CONTROL CIRCUIT NUMBERS CORRESPOND TO
THE NUMBER OF THE CONTROLLED POWER
CIRCUIT; e.g. CQA3-c1 WOULD CONTROL
CQA3-q1.
E. CIRCUITS TO DEVICES FORMING AN INTEGRAL
PART OF TERMINAL EQUIPMENT RECEIVE THE
TERMINAL EQUIPMENT DESIGNATION (e.g. THE
CIRCUIT TO CT'S IN CIRCUIT BREAKER XJ1
COULD BE DESIGNATED SU1-q1-XJ1). CIRCUITS
TO SEPARATELY MOUNTED DEVICES RECEIVE
THE DESIGNATION ASSIGNED TO THE DEVICE
(i.e. CQ24-q1-4C1 IS A CIRCUIT GOING TO
TRANS. OIL PUMP 4C1).
2. MULTI-CONDUCTOR CABLES ARE IDENTIFIED
BY SUFFIX "C"; i.e., 3/C INDICATES A
THREE-CONDUCTOR CABLE WHILE A NUMERAL
3 INDICATES THREE CONDUCTORS.
C. CIRCUIT AND ROUTING IDENTIFICATION
480V (FISH RELATED)
1. AS AN AID TO FURTHER IDENTIFICATION OF
VOLTAGE CLASS AND LOCATION OF THE
EQUIPMENT, THE FOLLOWING ARE APPLIED TO
SEPARATELY MOUNTED BREAKERS, DISCONNECT-
ING MOUNTED BREAKERS, DISCONNECTING
SWITCHES, CURRENT TRANSFORMER AND
VOLTAGE TRANSFORMERS.
TELEPHONE/PBX CIRCUITS, COMM CIRCUITS
CLOSED CIRCUIT TV (CCTV) VIDEO CIRCUITS
POWER CIRCUIT (120/240 OR 120/208 VAC)
ALARM CIRCUITS, ANNUNCIATOR CIRCUITS,
SELF-SYNCHRONOUS INDICATING CIRCUITS, RTD
AND TRANSDUCER OUTPUT CIRCUITS, RECORDER,
OTHER LOW-LEVEL SIGNAL CIRCUITS.
D. CONDUIT NUMBERS ARE GENERALLY IDENTICAL
TO THE CIRCUIT CONTAINED WITHIN THE
CONDUIT.
3-WAY SNAP SWITCH, 125V, 20A
SINGLE POLE SNAP SWITCH, 125V, 20A
CONTACTS (NC)
CONTACTS (NO)
DETAIL REFERENCE
TOP NO. INDICATES DETAIL
BOTTOM NO. INDICATES SHEET REFERENCED
POWER TRANSFORMER (ONE LINE DIAGRAM)
# INDICATES KVA RATING
MOTOR
# INDICATES HP RATING
SINGLE-POLE, SINGLE-THROW (SPST) SWITCH
120V, 20A DUPLEX RECEPTACLE
240V RECEPTACLE
AI
AIR
ALM/AH
AO
AUX
AWS
CP
CR
CS
CU
CV
BP
DI
DNET
DTAP
DO
DPM
DS
DSA
DT
FC
FM
FU
FZ
HOA
HMI
I/O
I/P
IY
IR
JB
LC
LE
LGTA
LGTB
LP
LS
LSPx
LSRA
LT
LGTSW
MDP
MTS
MCR
PB
PBL
PDT
PI
PL
PLC
PRX
PS
PT
PTT
PWR
PY
RABRK
RAHBRK
RAMTR
RAHMTR
RCPT
RPxF1
RPxF2
RPxM
RSPF
RSPM
RIO
RLS
RVSS
SCADA
SCR
SGCC
SOL/SV
SPD
SPHMTR
SPMTR
SS
STA
STP
TDR
TE
TI
TT
UTP
XMTR
YS
ZS
ZT
ZV
ZZ
ANALOG INPUT
AMPERE INTERRUPT RATING
ALARM/ANNUNCIATOR HORN
ANALOG OUTPUT
AUXILIARY
AUXILLARY WATER SUPPLY
CONTROL PANEL
CONTROL RELAY
CONTROL SWITCH
COPPER
CONTROL VALVE
BYPASS (CONTACTOR)
DISCREET INPUT
DEVICENET
DEVICENET TAP
DISCREET OUTPUT
DIGITAL POWER METER
DISCONNECT SWITCH
DEVICENET STARTER ASSEMBLY
DEVICENET TAP
FLOW CONTROLLER
FLOW METER
FUSE
VALVE POSITION (FLOW)
HAND-OFF-AUTO
HUMAN MACHINE INTERFACE
INPUT/OUTPUT
CURRENT TO PRESSURE TRANSDUCER
CURRENT CONVERTER
INDUCTION RELAY
JUNCTION BOX
LEVEL CONTROLLER
LEVEL ELEMENT
LIGHT FIXTURE A
LIGHT FIXTURE B
LIGHTING PANEL
LIMIT SWITCH
LIMIT SWITCH PIER #
LIMIT SWITCH RIGHT ABUTMENT
LEVEL TRANSMITTER
LIGHTING SWITCH
MAIN DISTRIBUTION PANEL
MANUAL TRANSFER SWITCH
MASTER CONTROL RELAY
PUSH BUTTON
PUSH BUTTON, LIGHTED
DIFFERENTIAL PRESSURE TRANSMITTER
PRESSURE INDICATOR
PILOT LIGHT
PROGRAMMABLE LOGIC CONTROLLER
PROXIMITY SWITCH
PRESSURE SWITCH
PRESSURE TRANSMITTER
PRESS TO TEST
POWER
PRESSURE CONVERTER
RIGHT ABUTMENT BRAKE
RIGHT ABUTMENT BRAKE HEATER
RIGHT ABUTMENT MOTOR
RIGHT ABUTMENT MOTOR HEATER
RECEPTACLE
RECEPTACLE PIER x FEMALE (x = PIER NUMBER)
RECEPTACLE PIER x FEMALE (x = PIER NUMBER)
RECEPTACLE PIER x MALE (x = PIER NUMBER)
RECEPTACLE SPARE MOTOR FEMALE
RECEPTACLE SPARE MOTOR MALE
REMOTE I/O
ROTARY LIMIT SWITCH
REDUCED VOLTAGE SOFT STARTER
SUPERVISORY CTRL & DATA ACQUISITION
SAFETY CONTROL RELAY
SPILLWAY GATE CONTROL CABINET
SOLENOID/SOLENOID VALVE
SURGE PROTECTIVE DEVICE
SPARE MOTOR HEATER
SPARE MOTOR
SELECTOR SWITCH
STATION (OPERATOR CNTRL)
SHIELDED TWISTED PAIR
TIME DELAY RELAY
TEMPERATURE ELEMENT
TEMPERATURE INDICATOR
TEMPERATURE TRANSMITTER
UNSHIELDED TWISTED PAIR
TRANSMITTER
AUX ATS SWITCH
LIMIT SWITCH
POSITION TRANSMITTER
PNEUMATIC PISTON ACTUATOR
POSITIONING LINEAR ACTUATOR (ELECT)
NEW CONDUIT IDENTIFICATION
PER SCHEDULE
ELEVATION/SECTION REFERENCE
TOP LETTER INDICATES ELEVATION/SECTION
BOTTOM NO. INDICATES SHEET REFERENCED
THERMOSTAT
CONTACTOR (OPERATING COIL)
PUSH TO TEST INDICATING LIGHT
(A=AMBER,G=GREEN,R=RED, W=WHITE,
Y=YELLOW, B=BLUE, ETC.)
RESISTIVE HEATER
(NUMBER INDICATES WATTAGE)
3-POLE DISCONNECT SWITCH,
EXTERNALLY OPERATED
(NUMBER INDICATES AMP RATING)
COMBINATION MOTOR STARTER
W/ EXTERNAL DISCONNECT
(NUMBER INDICATES NEMA SIZE)
SAMPLE DEVICE FUNCTIONS
LIMIT SWITCH (N.C.)
TEMPERATURE SWITCH
(N.O., CLOSES ON DROPPING TEMPERATURE)
LIMIT SWITCH (N.O.)
MASTER CONTACTOR
RAISE CONTACTOR
LOWER CONTACTOR
GENERAL NOTES
u
A
AF
AFF
AFG
AIC
AIR
AL
AT
ATS
AWG
BRK
PxBRK
PxHBRK
PxMTR
PxHMTR
CB
CKT
CPT
CPU
D/S
(E)
EGC
EF
EL
EM
EXST
F,FU
FCB
FDR
FLR
FLUOR
F/O
G/GND
GALL
GALR
GALV
GFCI
GFCIP
GFE
GPB
HH
HTR
INST
JB
LC
LT-FLEX
LTG
LSI
M/MTR
MCB
MCC
MCP
MH
MLO
MS
MPC
MTS
N
NA
NC
NO
OL
PB
PC
PDB
PH
PNL
PR
PS
PVC
RCPT
REF
RGS
SA
SF
SG
SGCC
SPD
SPDT
SPST
SS
TB
TYP
UG
U/S
UPS
V
VFD/VSD
VM
W
WP
WT
W/
T,XFMR
AMMETER, AMPERE
AMP FUSE, AMP FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPERE INTERRUPTING CAPACITY
AMPERE INTERRUPTING RATING
ALUMINUM
AMPERE TRIP
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BRAKE
PIER # BRAKE
PIER # BRAKE HEATER
PIER # MOTOR
PIER # MOTOR HEATER
CIRCUIT BREAKER
CIRCUIT
CONTROL POWER XFMR
CENTRAL PROCESSING UNIT
DOWNSTREAM
EXISTING
EQUIPMENT GROUNDING CONDUCTOR
EXHAUST FAN
ELEVATION
EMERGENCY
EXISTING
FUSE
FEEDER CIRCUIT BREAKER
FEEDER
FLOOR
FLUORESCENT LIGHTING
FIBER OPTIC
GROUND
GALLERY LEFT
GALLERY RIGHT
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GFCI PROTECTED
GOV'T FURNISHED EQUIPMENT
GALLERY PULL BOX
HAND HOLE
HEATER
INSTANTANEOUS
JUNCTION BOX
LIGHT CONTACTOR
LIQUID TIGHT FLEX CONDUIT
LIGHTING
LONG-TIME, SHORT-TIME, INSTANTANEOUS
MOTOR
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MANHOLE / METAL HALIDE
MAIN LUGS ONLY
MOTOR STARTER
MINI-POWER CENTER (XFMR AND PNL)
MANUAL TRANSFER SWITCH
NEUTRAL
NON-AUTOMATIC, NON-APPLICABLE
NORMALLY CLOSED
NORMALLY OPEN
OVERLOAD RELAY
PULL BOX
PHOTOCELL
POWER DISTRIBUTION BLOCK
PHASE
PANEL
PAIR
PRESSURE SWITCH
POLYVINYL CHLORIDE CONDUIT
RECEPTACLE
REFERENCE INFORMATION
RIGID GALVANIZED STEEL CONDUIT
SURGE ARRESTOR
SUPPLY FAN
SPILLWAY GATE
SPILLWAY GATE CONTROL CABINET
SURGE PROTECTION DEVICE
SINGLE-POLE DOUBLE-THROW
SINGLE-POLE SINGLE-THROW
STAINLESS STEEL
TERMINAL BLOCK
TYPICAL
UNDERGROUND
UPSTREAM
UNINTERRUPTIBLE POWER SUPPLY
VOLTS
VARIABLE FREQUENCY DRIVE
VOLTMETER
WATT
WEATHERPROOF
WATERTIGHT
WITH
TRANSFORMER
ORIGIN (COMPONENT)
INTERNAL WIRING
EXTERNAL WIRING
WIRE NUMBER
DESTINATION
WIRE NUMBER
XXXX/XXXX (XXXX)
DESTINATION TERMINATION
XXXX (XXXX)
MODULE SLOT
INPUT (I) OR OUTPUT (O)
TERMINAL NUMBER, IF
DIFFERENT THAN I/O CHANNEL
RIO:3:I.2[6]
PLC I/O WIRING NOMENCLATURE
INPUT OR OUTPUT
CHANNEL
REMOTE I/O
CHASSIS
CONTROL WIRING NOMENCLATURE
PANEL WIRING
1. THIS IS A TYPICAL SYMBOLS AND
ABBREVIATIONS SHEET, THEREFORE, SOME
SYMBOLS AND ABBREVIATIONS MAY NOT BE
USED WITHIN THIS DRAWING SET.
2. EXPOSED CONDUIT INSTALLATION ON
CONCRETE SLABS/PIERS SHALL BE
COORDINATED WITH EXISTING GRATING.
CONDUITS SHALL BE INSTALLED BELOW
GRATING (AS MUCH AS POSSIBLE) TO
AVOID TRIPPING HAZARDS.
3. IF REBAR IS ENCOUNTERED DURING A DRILLING
OPERATION, THE CONTRACTOR MUST OBTAIN
WRITTEN APPROVAL FROM THE STRUCTURAL
ENGINEER OF RECORD OR THE CONTRACTING
OFFICER BEFORE CUTTING THE REBAR.
4. ALL ABANDONED CONDUIT MUST HAVE THE
WATER REMOVED, THE ENDS CLEANED OF
DEBRIE/RUST AND THEN MUST BE SEALED WITH
A SILICONE COMPOUND ON BOTH ENDS TO
PREVENT FUTURE WATER ENTRY.
START OF RUN
SERVICE CODE OR
VOLTAGE CLASS
END OF RUN
CIRCUIT NUMBER
EXAMPLES
250W
DQ1-q1-MTS1
OL
OL
42X
42-1
OR
OR
OR
X
OR
Z
52-()
G.I.
J
1-()
W
M
M
E
XYZ
3P
XYZ
XYZ
A
M
R
L
ES504
ES404
120V, 20A SINGLE RECEPTACLE
ELECTRICAL ABBREVIATIONS
D. EXTERNAL CONTROL WIRE IDENTIFICATION
WIRE LABEL WITHIN CONTROL CABINET
WIRE LABEL AT CONTROL DEVICE OR EQUIPMENT
EXAMPLE:
CONTROL WIRE FROM CONTROL CABINET (SGCC1) TO ROTARY
LIMIT SWITH (RLS1). ORIGIN OF WIRE IN SGCC1 IS TERMINAL
BLOCK TB1-3 AND IT IS TERMINATED AT ROTARY LIMIT SWITCH
RLS1 ON TERMINAL T-1. INTERNAL WIRE NUMBER IS XXXXX.
SAME NOMENCLATURE APPLIES TO WIRING BETWEEN
CONTROL DEVICES OR EQUIPMENT
XXXXX/SGCC1/TB1-3
XXXXX/RLS1/T-1
TERMINATION POINT AT DESTINATION
WIRE NUMBER
DESTINATION CABINET OR EQUIPMENT
WIRE NUMBER
DESTINATION DEVICE OR EQUIPMENT
TERMINATION POINT IN SGCC1
NOMENCLATURE (CONT.)
NOMENCLATURE
PIER & ABUTMENT LIGHTING, FIXTURE A & B
(REPLACEMENT NOT PART OF CONTRACT)
A
AC TO DC RECTIFIER
CIRCUIT BREAKER INDICATED AS LOCK OUT-TAG OUT POINT
PIER & ABUTMENT MOTOR PATCH CORD
PTT
E-001
J E
N N
I N
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
G
R A
D E
L E
G E
N D
S
A
B
R E
V I A
T I O
N S
E
R
I M
K E
E
G E
C D
T R
S G
E
C D
J P
B
W I L L I A
M
F
O R
T U
E
S I
D
J R
L
E
X X
X d w g
BALTIMORE DISTRICT
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
D
I S
T R
I C
T
B A
L T
I M
O R
E
M
A R
Y L
A N
D
B
PTT
A
D
W
A
Y
S
P
I
L
L
W
A
Y
F
L
O
W
D
O
W
N
S
T
R
E
N
C
R
E
R
O
N
L
S O
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
060' 60'
SCALE: 1"= 60'
SCALE:1" = 60'
GENERAL SITE PLAN
NORTH
E-101
J E
N N
I N
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
G
R A
D E
G E
N E
R A
L
S
I T
E
P
L A
N
E
R
I M
K E
E
G E
C D
T R
S G
E
C D
J P
B
W I L L I A
M
F
O R
T U
E
S I
D
J R
L
E
X X
X d w g
BALTIMORE DISTRICT
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
D
I S
T R
I C
T
B A
L T
I M
O R
E
M
A R
Y L
A N
BOUNDARY OF WORK
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
A N
S I
D
J R
L
E
X X
X D
W G
(E) RIGHT
ABUTMENT
(E) PIER #4
(E) LEFT
ABUTMENT
(E) DIESEL GENERATOR
SHELTER
(E) DIESEL GENERATOR
SHELTER STAIRS
SCALE: 1"= 20'
20' 0 20'
SPILLWAY TAINTER GATE CONTROL
PLATFORMS (LEFT ABUTMENT,
PIERS 1 TO 4 AND RIGHT ABUTMENT),
SEE SHEETS ED103 AND E-103 FOR
CHANGES TO THESE AREAS
(E) MAINTENANCE ROADWAY
SEE SHEETS ED201 AND
E-201 FOR CHANGES TO
THE GALLERY LIGHTING
(E) GALLERY
ACCESS
HATCH
(E) GALLERY ACCESS HATCH
SCALE: 1" = 20'
ELECTRICAL SPILLWAY SITE PLAN
(E) PIER #3(E) PIER #2(E) PIER #1
BOUNDARY OF WORK
SPILLWAY AND DOWNSTREAM APRON
FL
O
W
NORTH
(E) GENERATOR SHELTER
EXTERIOR LIGHTING
SWITCH
(E) GENERATOR SHELTER
EXTERIOR LIGHT
S
DCQ1 CABINET CONTAINING
DQ1, LTR1 AND DR1 MOUNTED EXTERIOR
TO AND ON ROOF SLAB OF THE DIESEL
GENERATOR SHELTER
MTS1 ON ROOF SLAB OF THE
GENERATOR SHELTER
CONDUITS:
MDP-q1-MTS1
MDP-q2-MTS1
SEE NOTE 1
CONDUIT:
LP-r1-GPB1
SEE NOTE 2
SEE NOTE 3
DOOR SIDE OF DCQ1
CABINET, SEE SHEET
E-607
(E) CONCRETE SAFETY WALL
(E) SIDEWALK
(E) RIGHT
ABUTMENT
(E) GENERATOR
SHELTER
ENTRANCE DOORS
G E
C D
J P
B
E
R
I M
K E
E
G E
C D
T R
E-102
BALTIMORE DISTRICT
L E
C T
R I C
A L
S
P I L L W
T
E
P
L A
N
B A
L T
I M
O R
E
D
I S
T R
I C
T
J E
N N
I N
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
G
R A
D E
W I L L I A
M
F
O R
T U
E
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
M
A R
Y L
A N
D
NOTES:
1. ROUTE CONDUIT THROUGH CONCRETE WALL BEHIND PANEL DCQ1
AND UNDER SIDEWALK TO THE RIGHT ABUTMENT. SEAL CONDUIT
PENETRATIONS THROUGH THE CONCRETE WALL WITH APPROVED
SEALANT PER SPECIFICATIONS.
2. ROUTE CONDUIT FOR GALLERY LIGHTING AND THE GENERATOR
SHELTER LIGHT SWITCH FROM PANEL LP THROUGH THE GENERATOR
SHELTER CONCRETE WALL, ALONG THE EXTERIOR CONCRETE WALL
AND ENTER THE GALLERY THROUGH THE METAL EDGE OF THE
GALLERY ACCESS HATCH TO THE NEW GALLERY PULL BOX, GPB1.
SEAL CONDUIT PENETRATIONS THROUGH THE CONCRETE WALL WITH
APPROVED SEALANT PER SPECIFICATIONS.
3. ROUTE CONDUIT THROUGH GENERATOR SHELTER CONCRETE CEILING
TO THE MANUAL TRANSFER SWITCH, MTS1. SEAL CONDUIT
PENETRATIONS THROUGH THE CONCRETE CEILING WITH APPROVED
SEALANT PER SPECIFICATIONS.
TOP TO BOTTOM:
DR1-r1-JB6
DQ1-q1-SGCC5
DQ1-q1-SGCC4
DQ1-q1-SGCC3
DQ1-q1-SGCC2
DQ1-q1-SGCC1
CONDUIT MOUNTED UNDER
SIDEWALK, SEE E-103
SCALE: 1" = 5'-0"
GENERATOR SHELTER DETAILED PLAN (NEW WORK)
(E) PAD MOUNTED UTILITY
TRANSFORMER
SCALE: 1"= 5'
5' 0 5'
24'
22'
41' FROM CL TO GEN SHELTER
S O
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
#2/0 GROUND DOWN TO GROUNDING
ELECTRODE, PIER 3 ONLY.
DN.
F L
O W
M A
T C
H
L
I N
E
A
2-#12, 1/2C FOR FUEL
OIL SHUT OFF
SOLENOIDS
AA
CONNECT TO
PLATFORM STEEL.
SPARE
MOTOR
#2 GRD.
FACE OF LEFT
ABUTMENT
#2/0 GND
SIDEWALK BOX 12"X12"X8",
ALL CONDUITS AND BOX
ABANDONED, DEMO
CONDUCTORS
SIDEWALK
SIDEWALK BOX 24"X18"X8",
ALL CONDUITS AND BOX
ABANDONED, DEMO
CONDUCTORS
CURB
EL. 1511.69
MOTOR
#2/0 GND
MOTOR
#2 GRD.
BRAKE
FLOODLIGHT-TYPICAL
1"C FOR UTILITY
METERING WIRE
PLUG CONDUITS FOR
INSTALLATION OF
CABLES BY OTHERS
GROUND INSERT AT EL. 1510.00
4" EMPTY
CONDUIT FOR
UTILITY
PRIMARY FEED
ELECTRIC
UTILITY
METER
2" EMPTY CONDUIT FOR TELEPHONE
2" CONDUIT FOR
TELEPHONE
4" EMPTY CONDUIT 24" MIN
BELOW FINISHED GRADE
AT SHOULDER FOR
ELECTRIC UTILITY CO.
PRIMARY SERVICE TO
TRANSFORMER
SIDEWALK BOX 10"X10"X8",
ALL CONDUITS AND BOX
ABANDONED, DEMO
CONDUCTORS
1" EMPTY CONDUIT
SIDEWALK BOX 14"X14"X8"
ALL CONDUITS AND BOX
ABANDONED, DEMO CONDUCTORS
15 KVA-TRANSFORMER 480-208/120V
MAIN DISTRIBUTION PANEL MDP
#2/0 GND
MAIN SERVICE DISCONNECT
CIRCUIT BREAKER, 3P-100A
LP12 SWITCH LEG
& NEUTRAL
BATTERY
CHARGER
#2/0 GND
FUEL OIL TANK
ENGINE
JACKET WATER
HEATER
DIESEL GENERATOR ROOM
#2 GND
D
D
D
GALLERY
ACCESS
ENTRANCE
ATS
MAIN SERVICE
DISCONNECT CB
3P-100A-480V
EL. 1504.08
BATTERY
CHARGER
FUEL OIL
TANK
PANEL
MDP
TELEPHONE PULL BOX 12X12X4
TRANSFORMER 15 KVA
480V:120/208
GATE CONTROLLER
C OF PIERS
30KW DIESEL
GENERATOR
LP8,10,9,11
A
#2 GRD
2-#12, "C
TO GENERATOR
JACKET HEATER &
BATTERY, 3/4"C
LIGHT
SWITCH
2-#12, 3/4"C
RCPT
WEATHERPROOF GENERATOR SHELTER
STAIRS LIGHT SWITCH
SECURED TO RAILING POST AT EL. 1515.25,
SEE E-102
A
B B BB
A
A
A A
HEATER 3 KW
1PH-208V
7'-0" AFF
WATERTIGHT
PULL BOX
24"X24"X12"
C EL. 1511.2
C
L
TYPICAL PIERS NO.1, 2, 3 & 4LEFT ABUTMENT RIGHT ABUTMENT
2-#10, 3/4"C
3-#8, 1"C
2-#12, 3/4"C
LIMIT
SWITCH
2-#12, 1/2"C
HEATER WIRES
LP1,3,5:
4-#6, 1-1/4"C
LIGHTING
PANEL,
DETAIL 2
3-#12, 3/4"C
3-#8, 1"C
2-#10, 3/4"C
2-#12, 3/4"C
LIGHTING
PANEL
GATE CONTROLLER
10-#12, 1-1/4"C
LIMIT SWITCH
2-#12, 3/4"C
3-#8, 1"C
2-#12, 3/4"C
4-#12, 3/4"C
2-#12, 3/4"C
10-#12, 1-1/4"C
2-#12, 3/4"C
4-#10 & 3-#12, 3/4"C
GALLERY LIGHTS
& CONTROL
LP2,4,6:4-#10, 3/4"C
LP2,4,6:4-#10 & 5-#12, 1-1/4C
DOWN TO PULL BOX IN
GALLERY WALL
4-#12, 3/4"C
3-#12, 3/4"C
SEE DETAIL 1
THIS SHEET
PANEL
LP
TRANSFORMER
PAD
NOTES:
1. BOLD INDICATES EQUIPMENT, CONDUIT, AND CONDUCTORS TO BE
REMOVED. IF REBAR IS ENCOUNTERED DURING A DRILLING
OPERATION, THE CONTRACTOR MUST OBTAIN APPROVAL FROM THE
STRUCTURAL ENGINEER OF RECORD OR THE CONTRACTING OFFICER
BEFORE CUTTING REBAR.
2. DEMO EXISTING SPILLWAY GATE CONTROL CABINETS (SGCC)
AND LIGHTING PANELS.
3. REMOVE EXISTING CONDUCTORS AND EXPOSED CONDUITS
AS INDICATED ON PLANS. THESE CONDUITS AND CONDUCTORS
INCLUDE, BUT ARE NOT LIMITED TO, THOSE CONNECTED TO THE
BRAKE, MOTOR, GATE CONTROLLER PANEL, LIGHTING PANEL, LIGHT
FIXTURES AND LIMIT SWITCH. UNLESS INDICATED, REPLACING LIGHT
FIXTURES IS NOT PART OF THIS CONTRACT. EMBEDDED CONDUITS
ARE TO REMAIN. REMOVE WATER FROM ALL EXISTING UN-USED
EMBEDDED CONDUIT, GROUT ENTIRE LENGTH AND SEAL CONDUITS
ON BOTH ENDS USING A URETHANE SEALANT, PER SPECIFICATIONS.
4. PIERS 1,2,3,4, LEFT TO RIGHT CONDUITS:
3-#8 (TO ALTERNATE MOTOR RECEPTACLE ON ADJACENT
PIERS TO LEFT) , 1"C
MDP4:6-#8, CONTROLLER, 1"C
MDP1:6-#8, CONTROLLER, 1"C
3-#8, 1"C (FROM ADJACENT CONTROLLER TO RIGHT)
2-#10, 3/4"C (LIGHT B)
LP1,3,5:4-#6 & 2-#10 (TO FLOOD LIGHT ON ADJACENT PIER) 1-1/2"C
5. PIER 2,3,4 ONLY, TOP TO BOTTOM CONDUITS:
3-#8, 1"C (ADJACENT CONTROLLER TO RIGHT CONNECTED TO
ALTERNATE MOTOR RECEPTACLE) 1"C
MDP1:3-#8, CONTROLLER, 1"C
MDP4:3-#8, CONTROLLER, 1"C
MDP2:3-#8, 480V RECEPTACLE, 1"C
LP1,3,5:4-#6 & 2-#10 (FLOOD LIGHT ON ADJACENT PIER), 1-1/2"C
6. PIER 1 TO LEFT ABUTMENT ONLY, TOP TO BOTTOM CONDUITS:
3-#8, 2-#12, 1"C (PIER 1 CONTROLLER TO LEFT ABUTMENT
ALTERNATE MOTOR RECEPTACLE), 1"C
MDP2:3-#8, 480V RECEPTACLE, 1"C
LP1,3,5:4-#6 & 2-#10 (TO FLOOD LIGHT ON LEFT ABUTMENT), 1-1/2"C
7. PIER 4 TO RIGHT ABUTMENT ONLY, TOP TO BOTTOM CONDUITS:
3-#8, 1"C (LEFT ABUTMENT CONTROLLER CONNECTED TO
ALTERNATE MOTOR RECEPTACLE) 1"C
MDP1:3-#8, CONTROLLER, 1"C
MDP4:3-#8, CONTROLLER, 1"C
MDP2:3-#8, 480V RECEPTACLE, 1"C
LP1,3,5:4-#6 & 2-#10 (FLOOD LIGHT ON ADJACENT PIER), 1-1/2"C
8. RIGHT ABUTMENT ONLY, LEFT TO RIGHT CONDUITS:
LP1,3,5:4-#6 & 2-#10 (TO FLOOD LIGHT ON PIER 4), 1-1/4"C
3-#8, 1"C (TO ALTERNATE MOTOR RECEPTACLE ON PIER 4)
MDP4:6-#8, CONTROLLER, 1-1/2"C
MDP1:6-#8, CONTROLLER, 1-1/2"C
9. PULL BOX IN SIDEWALK, LEFT TO RIGHT CONDUITS
(FIELD VERIFY CONDUIT/CONDUCTORS AND REMOVAL):
4-#10 & 5-#12, 1-1/4"C, GALLERY LIGHTS & CONTROL, GENERATOR
SHELTER STAIR LIGHT SWITCH (LP12 CIRCUIT, SEE E-102)
LP1,3,5:4-#6, 1-1/4"C
MDP4:3-#8, CONTROLLER, 1"C
MDP1:3-#8, CONTROLLER, 1"C
MDP2:3-#8, 480V RECEPTACLE, 1"C
10. LEFT TO RIGHT CONDUITS (NOT WITHIN SCOPE OF WORK, REF ONLY):
LP12: GENERATOR SHELTER STAIR LIGHT FIXTURE, 2-#12, 3/4"C
(NOT GENERATOR SHELTER LIGHT SWITCH, SEE E-102)
LP10:GENERATOR SHELTER LIGHT SWITCH, 2-#12, 3/4"C
LP8,LP9&11,LP10 GEN SHELTER LIGHT FIXTURE:5-#12, 3/4"C
11. TOP TO BOTTOM CONDUITS:
LP1,3,5:4-#6, 1-1/4"C (DEMO CONDUCTORS, LEAVE CONDUIT AS
1-1/4" SPARE)
LP12 & SWITCH LEG, 2-#12, 1-1/4"C
SPARE 3/4"C
12. RIGHT ABUTMENT ONLY, TOP TO BOTTOM CONDUITS:
MDP1-3 #8, CONTROLLER, 1"C
MDP2:3-#8, 480V RECEPTACLE, 1"C
MDP4:3-#8, CONTROLLER, 1"C
LP1,3,5:4-#6, 1-1/4"C
13. LEFT TO RIGHT CONDUITS:
MDP2:3-#8, 480V RECEPTACLE, 1"C
MDP1:3-#8, CONTROLLER, 1"C
MDP4:3-#8, CONTROLLER, 1"C
LP1,3,5:4-#6, 1-1/4"C
4-#10 &5-#12, 1-1/4"C GALLERY LIGHTS & GENERATOR SHELTER
STAIR LIGHT SWITCH
14. CIRCUIT REFERENCE DESIGNATORS 01, 02, 03, 04, 05, 06, 10, 11, 12, 13,
14, 15, 16, 19 ARE EXISTING CIRCUITS AND MODIFICATION TO THESE
ARE NOT PART OF SCOPE OF WORK. THESE ARE SHOWN FOR
REFERENCE ONLY.
LIGHTING
PANEL
3-#8, 1"C 3 #8, 1"C
SEE NOTE 4
CONNECT TO
PLATFORM STEEL
DETAIL 1 THIS SHEET
SEE NOTE 5
SEE NOTE 6
SEE NOTE 7 SEE NOTE 7
SEE NOTE 8
#2/0 GRD
#2/0 GND
BRAKE
SIDEWALK BOX
24"X18"X8" ALL
CONDUITS AND
BOX ABANDONED,
DEMO
CONDUCTORS
SEE NOTE 9
SEE NOTE 10
#2 GND
TO GENERATOR
LIGHT
SWITCH
SEE NOTE 11
90 DEGREE
TURN IN WALL
SEE NOTE 12
FACE OF RIGHT
ABUTMENT
GENERATOR CONTROL PANEL
TRANSFER SWITCH, 100A, 3P
GENERATOR
BREAKER
PANEL
LP
SEE NOTE 12
SEE
NOTE 13
M A
T C
H
L
I N
E
A
END OF
BRIDGE
C
CC
SCALE:
" = 1'-0"
GENERATOR SHELTER PLAN
SCALE:
" = 1'-0"
SPILLWAY PLAN
NOT TO SCALE
TYPICAL MOTOR RECEPTACLE STAND
NOT TO SCALE
TYPICAL PLATFORM LIGHTING PANEL
SCALE: NTS
GENERATOR SHELTER ELEVATION
D
SEE NOTE 6
GALLERY PULL
BOX
SEE NOTE 14
MOTOR RECEPTACLE STAND:
ALL MOUNTING PLATES,
VERTICAL SUPPORTS,
MOUNTING HARDWARE,
RECEPTACLES, CONDUIT AND
CONDUCTORS ARE TO BE
REMOVED AND REPLACED.
ED103
J E
N N
I N
N
D O
L P
H
L
A K
E
S P
I L
L W
A Y
E L
E C
T R
I C
G
R A
D E
S P
I L L W
Q U
I P
M E
N T
D E
M O
L I T
I O
N
E
R
I M
K E
E
G E
C D
T R
S G
E
C D
J P
B
W I L L I A
M
F
O R
T U
E
S I
D
J R
L
E
D
X X
X d w g
BALTIMORE DISTRICT
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
B A
L T
I M
O R
E
D
I S
T R
I C
T
B A
L T
I M
O R
E
M
A R
Y L
A N
D
3-#8 & 2-#12, 1"C
THE LIGHTING PANEL,
CONDUIT, CONDUCTORS,
VERTICAL SUPPORTS AND ALL
HARDWARE ASSOCIATED WITH
THE LIGHT PANEL STANDS ARE
TO BE REMOVED AND
REPLACED (NEW JUNCTION
BOXES ARE JB1 TO JB6, SEE
E-103).
SCALE:
"= 1'-0"
4' 0 4'
EXISTING RECORD DRAWINGS
15168/SE-1 POWER AND LIGHTING PLAN
24'
22'
41'-0"
S O
L I C
I T
A T
I O
N
N
O
F I
M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
P O
R T
L A
S
T R
I C
T
P O
R T
L A
N D
O
R E
G O
N
D
C
B
A
54321
SCALE:
"= 1'-0"
#2/0 GROUND DOWN TO GROUNDING
ELECTRODE, PIER 3 ONLY.
DN.
F L
O W
AA
SPARE
MOTOR
(SPMTR)
#2 GROUND
(TYPICAL ALL
PIERS &
ABUTMENTS)
FACE OF LEFT
ABUTMENT
#2/0 GND
SIDEWALK
CURB
EL. 1511.69
MOTOR
MOTOR
BRAKE
FLOODLIGHT-TYPICAL
1"C FOR UTILITY
METERING WIRE
GROUND INSERT AT EL. 1510.00
ELECTRIC
UTILITY
METER
2" EMPTY CONDUIT FOR TELEPHONE
#2/0 GND
MAIN SERVICE DISCONNECT
CIRCUIT BREAKER, 3P-100A
BATTERY
CHARGER
DIESEL GENERATOR ROOM
D
D
D
GALLERY
ENTRANCE
ATS
MAIN SERVICE
DISCONNECT CB
3P-100A-480V
EL. 1504.08
BATTERY
CHARGER
FUEL OIL
TANK
PANEL
MDP
TELEPHONE PULL BOX 12X12X4
TRANSFORMER 15 KVA
480V:120/208
SGCC1
C OF PIERS
30KW DIESEL
GENERATOR
A
TO GENERATOR
JACKET HEATER &
BATTERY
RCPT
A
B B BB
A
A
A A
WATERTIGHT
PULL BOX
24"X24"X12"
C EL. 1511.2
L
TYPICAL PIERS NO.1, 2, 3 & 4 (PIER 1 SHOWN)LEFT ABUTMENT RIGHT ABUTMENT
JB2-r1-2LGTB
SGCC1-r1-P1HMTR
LIMIT
SWITCH
LIGHTING
J-BOX
JB1,
DETAIL 2
JB2-r1-JB1
SPMJB-q1-SPMTR
JB1-r1-1LGTA
JB1-r1-1RCPT
JB6
SGCC5 (GATE CONTROLLER 5)
SGCC5-c1-LSRA
LIMIT SWITCH
SGCC5-r1-RAHMTR
6LGTA-r1-6LGTA
SGCC5-r1-RABRK
JB6-r1-6LGTB
SGCC1-c1-LSP1
SGCC1-r1-P1BRK
JB6-r1-6LGTA
JB6-r1-6RCPT
SEE DETAIL 1
THIS SHEET
PANEL
LP
TRANSFORMER
PAD
NOTES:
1. BOLD INDICATES EQUIPMENT, CONDUIT, AND CONDUCTORS
TO BE INSTALLED. IF REBAR IS ENCOUNTERED DURING A
DRILLING OPERATION, THE CONTRACTOR MUST OBTAIN
APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD OR
THE CONTRACTING OFFICER BEFORE CUTTING REBAR.
2. THE 480V RECEPTACLE ON EACH ABUTMENT AND PIER IS
ELIMINATED IN THE NEW WORK.
3. CIRCUIT REFERENCE DESIGNATORS 01, 02, 03, 04, 05, 06, 10, 11,
12, 13, 14, 15, 16, 19 ARE EXISTING CIRCUITS AND MODIFICATION
TO THESE ARE NOT PART OF THE SCOPE OF WORK. THESE
ARE SHOWN FOR REFERENCE ONLY.
4. FOR CLARITY, NOT ALL CONDUITS ARE SHOWN. SEE E-702 AND
E-703 FOR THE COMPLETE LIST.
5. SEE E-501 FOR SGCC PANEL MOUNTING DETAILS.
6. REPLACEMENT OF THE THE 120V RECEPTACLES ON EACH
ABUTMENT AND PIER IS NOT WITHIN THE SCOPE OF WORK IN
THIS PROJECT. RUNNING NEW CONDUCTORS TO THE
RECEPTACLES IS WITHIN THE SCOPE OF WORK.
7. A FUTURE PROJECT WILL HAVE A MOTOR LINE SHAFT ABOVE
THE JUNCTION BOXES, THEREFORE IT IS IMPORTANT NOT TO
MOUNT THE JUNCTION BOX ANY HIGHER THAN IS SHOWN ON
THIS DRAWING.
8. REPLACE EXISTING VERTICAL STRUTS, MOUNTING PLATE,
MOUNTING HARDWARE, RECEPTACLES, CONDUIT AND
CONDUCTORS WITH NEW. MOUNTING PLATES MUST
ACCOMMODATE THREE RECEPTACLES, TWO FEMALE AND ONE
MALE, WITH THE MALE CONNECTED TO THE MOTOR. THE
VERTICAL MOUNTING PLATE MUST BE 1/4" PAINTED,
GALVANIZED STEEL WELDED TO THE VERTICAL STRUT.
9. CONTRACTOR MUST SUPPLY SHOP DRAWINGS FOR APPROVAL
BY THE CONTRACTING OFFICER BEFORE CONSTRUCTION OF
THE PLATFORM LIGHTING JUNCTION BOX ASSEMBLY.
CONTRACTOR MUST NOT MOUNT THE ASSEMBLY OVER AN
EXISTING EXPANSION JOINT AND MUST CONTACT THE
CONTRACTING OFFICER FOR THE PROPER LOCATION FOR
MOUNTING THE ASSEMBLY.
10. A SEPARATE PROJECT NOT ASSOCIATED WITH THIS CONTRACT
AND AFTER THIS CONTRACT WILL MOVE ALL 5 OF THE SGCC
PANELS TO THE FAR NORTH SIDE OF THE SAME PIER.
THEREFORE THE CONTRACTOR MUST LEAVE AN EXTRA 25
FEET OF POWER AND GROUND CONDUCTORS COILED IN THE
BOTTOM OF THE SGCC CABINET. THIS ONLY APPLIES TO THE
CONDUCTORS RUNNING FROM DQ1 TO THE SGCC. AN
EXAMPLE FOR SGCC1 WOULD BE THE CONDUCTORS
DQ1-q1-SGCC1.
BRAKE
#2 GND
TO GENERATOR
LIGHT
SWITCH
90 DEGREE
TURN IN WALL
FACE OF RIGHT
ABUTMENT
GENERATOR CONTROL PANEL
TRANSFER SWITCH, 100A, 3P
PANEL
LP
END OF
BRIDGE
2" CONDUIT
FOR TELEPHONE
NAMEPLATES
RPxF1
FEEDER
RECEPTACLE
CROUSE HINDS
CAT # AR337
RPxM MOTOR
RECEPTACLE
CROUSE HINDS
CAT # APQ337
RECEPTACLE
BOX,CROUSE
HINDS CAT #
ARRH 33
(3 PLACES)
1/4" PAINTED, GALVANIZED
STEEL MOUNTING PLATE
WELDED TO VERTICAL
" STRUT.
12"X12"X8" STAINLESS
STEEL LIGHTING
JUNCTION BOX NEMA 4X
ENCLOSURE, JB1 TO JB6.
VERTICAL SUPPORTS AND
HARDWARE
SCALE:
" = 1'-0"
GENERATOR SHELTER PLAN
SCALE:
" = 1'-0"
SPILLWAY PLAN
SCALE: 1" = 1'-0"
TYPICAL RECEPTACLE STAND
SCALE: 1" = 1'-0"
TYPICAL PLATFORM LIGHTING J-BOX (JB1 - JB6)
SCALE:NTS
GENERATOR SHELTER ELEVATION
D
TO MTS1 ON
GENERATOR
SHELTER ROOF
SEE E-102
CONDUIT DOWN INTO
GALLERY ENTRANCE
MAIN DISTRIBUTION PANEL MDP
15 KVA-TRANSFORMER 480-208/120V
TO SPILLWAY
SEE MATCHLINE
ABOVE
OUTLINE OF NEW
DCQ1 ON
GENERATOR
SHELTER ROOF
(EL 1514.77)
OUTLINE OF NEW
MTS1 ON
GENERATOR
SHELTER ROOF
(EL 1514.77)
CONDUITS MDP-q1-MTS1 &
MDP-q2-MTS1 PENETRATE
GENERATOR SHELTER
CEILING TO MTS1 LOCATED
ON GENERATOR SHELTER
ROOF
JB1-r1-1LGTB
2LGTB-r1-2LGTB
TOP TO BOTTOM:
DR1-r1-JB6
DQ1-q1-SGCC5
DQ1-q1-SGCC4
DQ1-q1-SGCC3
DQ1-q1-SGCC2
DQ1-q1-SGCC1
CONDUIT MOUNTED UNDER
SIDEWALK, SEE E-102
JB2
CONDUIT LP-r1-GPB1
CONDUIT LP-r1-GPB1
CONDUIT MDP-q1-MTS1
CONDUIT MDP-q2-MTS1
M A
T C
H
L
I N
E
A
M A
T C
H
L
I N
E
A
TOP TO BOTTOM:
JB2-r1-JB1
SGCC1-q1-SPMJB
SGCC1-q1-SPMJB
DQ1-q1-SGCC1
LEFT TO RIGHT:
JB2-r1-JB1
JB3-r1-JB2
LEFT TO RIGHT:
JB6-r1-JB5
DR1-r1-JB6
DQ1-q1-SGCC5
SGCC5-q1-RP4F2
2LGTA-r2-2LGTA
JB2-r1-2LGTA
JB2-r1-2RCPT
SEE NOTE 3
CONDUIT
MDP-q1-MTS1
CONDUIT
MDP-q2-MTS1
BALTIMORE DISTRICT
B A
L T
I M
O R
E
D
I S
T R
I
E
C D
J P
B
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
E
R
I M
K E
E
G E
C D
T R
E-103
S P
I L L W
U
I P
M E
N T
J…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.