Attachment_2_-_SOW_Drawings.pdf
PDF 1 MB Posted
- Attached to
- Automatic Entry/Exit Doors at BLDG 601 Federal contract opportunity
- Solicitation number
- W912D0-19-Q-0001
About this file
Attachment 2 - SOW Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_3_-_Construction_Wage_Rate_Determination_Rev1.pdf | ||
| D0-19-Q-0001_Amendment_to_Solicitation.pdf | ||
| Attachment_1_-_Statement_of_Work_(SOW)_Rev1.pdf | ||
| Attachment_7_-_EIFS_Details_(Drawings).pdf | ||
| Attachment_5_-_Environmental_Review.pdf | ||
| Attachment_8_-_Responses_to_Questions.pdf | ||
| Attachment_6_-_A-10_Wall_Sections_HPSC2610M.PDF | ||
| W912D0-19-Q-0001_Automatic_Doors.pdf | ||
| Attachment_1_-_Statement_of_Work_(SOW).pdf | ||
| Attachment_4_-_Submittal_Register.xls | XLS spreadsheet | |
| Attachment_3_-_Construction_Wage_Rate_Determination.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E xterio r E n try D o or Inte rio r E ntry D oor
Interio r E xit D oor
E xterio r E x it D o or
B
LD
G
P
F ire A larm P u ll S tation
T e m p e ra ture C on trol D ial
Commissary Automatic Doors
COM 00004-4J
C :\P ro je ct\G re e ly R e fe re n ce\D w gs\N ew
Logo.JP G
1 Existing Doors
6.5"
7.5"
B
LD
G
P an el 1B A dd
(1) 1
5A b re aker
(2) #8 A W
G T
H W
N
(1) # 8 A
W G
G nd
/4
" E M
T
(2) #8 A W
G T
H W
N
(1) # 8 A
W G
G nd
/4
" E M
T
P an el 1H A dd
(1) 1
5A b re akers
96" 96"
2" m in
2" m in
2" m in
2" m in
P
88"
Commissary Automatic Doors
COM 00004-4J
C :\P ro je ct\G re e ly R e fe re n ce\D w gs\N ew
Logo.JP G
1 Proposed Doors
N o tes:
* E lectrica l re com m e nd atio ns sh ow n he re are ba se d on
S ta nley A ccess A utom atic
D u ra -G lid e D o ors. In de pe nd e nt calcu la tion s sho uld be m a de to de term in e conductor, co nd uit & b re ake r size s, a cco un ting fo r the do or e le ctrica l re qu ire m e nts an d vo ltage drop if a ltern a te do ors a re used.
* W h ile m ultiple do ors ca n b e o n a sing le circuit, e ach d o or sh all be insta lle d to be able to sh ut it d o w n a s n e ed ed w itho ut a ffe cting th e o pe ra tion of the o the r d oo rs on th a t circuit. If o ne d o or o n a circu it n ee d s to b e sh ut d ow n , th e o th e r do ors o n th at sam e circuit shall co ntin ue to be op eratio nal.
77.5"
S ta nle y A ccess D oor
D u ra-G u ard 20 w ith
" m in cle ar op e ning
T he doo r is larg er tha n the d oo rw ay.
T his is in ord e r to h ave a larger clea r o pen ing
. M oun t d oor ou tsid e do orw ay.
2" m in
2" m in
S ta nle y A ccess D oor
D u ra-G u ard 30
0 do ors w ith
" m in . clea r op ening
R e locate e xisting fire alarm to w all n ear th e "F ire A larm
S ystem
A nn un ciator"
C u t the se po rtio n s o f the w a ll to incre ase th e size o f th e do o rw a y to fit the d oor.
P
R e lo cate the
T em p era ture C o n trol D ia l ap px.
2" to the
N orth o n the sam e w all
Commissary Automatic Doors
COM 00004-4J
C :\P ro je ct\G re e ly R e fe re n ce\D w gs\N ew
Logo.JP
1 Proposed Entry Doors Details
" m in
.5
S ta n le y A cce ss D o or D ura -G u a rd do o rs w ith
" clea r o p en ing
C ut the se p o rtio n s o f th e w all to in cre ase th e size o f th e d oo rw ay to fit th e do or.
S ta n le y A cce ss D o or D ura -G u a rd do o rs w ith
" clea r o p en ing
" m in
T h e d oo r is la rg e r th a n the d oo rw ay.
T h is is in o rd e r to h ave a la rge r clea r o p en ing
. M o un t d oo r in sid e d o orw ay.
Commissary Automatic Doors
COM 00004-4J
C :\P ro je ct\G re e ly R e fe re n ce\D w gs\N ew
Logo.JP
1 Proposed Exit Door Details
B acker R od & D O
W 795 B uilding Sealant
E
IFS
B eyond
D rip
6" EIFS
R einforcing M esh 4.3 E m bed in G enesis D M
D ryvit - G enesis D M
D ryvit - Finish
D ryvit - G enesis D M
D ryvit - B ackStop N T
E P
S Insulation -
(6"
) Single Layer A dhered w / D ryvit G enesis D
M
2.5# D iam ond Lath by AM
IC
O M ech. A ttached w
/ C oncrete Fasteners
7" O
.C . V ertically & 16" O
.C . H orizontally M inim um
12 " O verlap V ertically & 1" H orizontally
O verlap on Flange O f Tim Accessories
A pply V ertically or H orizontally
D ryvit - G enesis D M
8" M in
D ryvit - G enesis D M
D ryvit - Finish
D ryvit - R einforcing M esh 4.3
O verlap M in 8" @ C orner
D ryvit - G enesis D M
D ryvit - G enesis D M
8" M in
D ryvit - B ackStop N T
E P
S Insulation
R einforcing M esh 4.3 E m bed in G enesis D M
2.5# D iam ond Lath by AM
IC
O
D O
O R
H E
A D
D E
T A
IL
1E
P S
P R
E P
A R
A T
IO
N
W
A
LL O
P E
N
IN
G S
E
IFS
A
S S
E M
B
LY
- T Y
P
IC
A L
4 E
IFS
O U
T S
ID
E
C O
R N
E R
- T Y
P
IC
A L
Commissary Automatic Doors
COM 00004-4J
C :\P ro je ct\G re e ly R e fe re n ce\D w gs\N ew
Logo.JP
1 EIFS Details
| L-1 Existing Doors |
| L-2 Proposed Doors |
| L-3 Proposed Entry Door Details |
| L-4 Proposed Exit Door Details |
| A-1 EIFS Details |
File details come from the government source that posted it.