QA_W912CH24R0183.xlsx
XLSX spreadsheet 10 KB Posted
- Attached to
- Wiring Harness Assembly; NSN: 5995-01-362-6368
- Solicitation number
- W912CH-24-R-0183
About this file
The file is a Questions and Answers (QA) document for Solicitation W912CH-24-R-0183, a Wiring Harness Assembly procurement by the U.S. Army Contracting Command - Detroit Arsenal. The Q&A addresses two key technical questions: first, a clarification about phosphate testing requirements for cable assembly connectors (which were subsequently removed via Solicitation Amendment 0001), and second, confirmation of specific terminal part numbers (9338561-1 and 9338561-2) that were queried by a potential bidder.
The related federal contract opportunity details include a Small Business Set-Aside for 71 Wiring Harness Assemblies (NSN: 5995-01-362-6368, Part Number: 12918942) with a one-year buying option. The procurement is a Firm Fixed Price contract requiring Joint Certification Program (JCP) export control certification, ISO 9001:2015 certification, and Military Packaging - Level B. Bidders must request Technical Data Package (TDP) access through SAM.gov, with proposals to be submitted electronically to Contract Specialist Kerri E. Ginter.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912CH24R0183_Solicitation AMD 0001.pdf | ||
| QA_W912CH24R0183.xlsx | XLSX spreadsheet | |
| W912CH24R0183.pdf | ||
| Technical Data Package (TDP).zip | ZIP file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Number | QUESTION | ANSWER |
| 1 | The Phosphate Test procedure appears to not be needed for this cable assembly. The metal connectors are purchased already coated, so we would not be adding any coating to the connectors. If we are not adding any additional coating, we can’t submit a test procedure and samples as section A004 instructs. |
| Can we get concurrence that we have interpreted the requirement correctly and the A004 does not apply to this configuration of cable assembly? | Upon further review, it was determined that light Phosphate is not required. The soliciation has been updated to remove phosphate testing requirements. Please see attached Solicitation Amendment 0001. | ||
| 2 | We’ve reviewed the parts list and are unable to locate the following items: Find 31: Part number 9338561-1 Find 32: Part number 9338561-2 Could you please check to see if there are alternative part numbers available or if these terminals might be listed under a different designation? | The Terminal part numbers 9338561-1 (NSN: 5940-01-205-0397) and 9338561-2 (NSN: 5940-01-205-0398) are listed on drawing 9338561 Rev B (Cage code: 19200) named DR_9338561_19200_B_001_001 within the TDP. Parts are listed as active on Haystack, and don't have an alternative part number. |
File details come from the government source that posted it. Updated .