Revision1-Attachment2-Drawings-W912C324R0003-GeneralRepairsBldg509_20240715.pdf
PDF 12 MB Posted
- Solicitation number
- W912C324R0003
About this file
The provided document is a set of drawings for Amendment 0001 to Solicitation W912C324R0003 for General Repairs to Building 509 at Fort Buchanan, Puerto Rico. The solicitation is a Firm Fixed Price contract set aside for 100% Small Business, with a magnitude between $1,000,000 and $5,000,000. The North American Industry Classification System (NAICS) code is 236200, Commercial and Institutional Building Construction, with a $45 million size standard. The proposal is due on July 31, 2024 at 10:00 AM local time. Offerors must submit a detailed breakdown for Contract Line Item Numbers (CLINs) 0001 and 0002 separately, and ensure any future amendments issued are signed and submitted with the proposal. Vendors must be registered and active in the System for Award Management (SAM) database to be eligible for award.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N x x x x x x x x x
SO
U
TH
T
ER
M
IN
A
L R
O A
D
ISABELLA ST.
SOUTH TERMINAL RD.
PUNTA BORINQUEN
(FORMER RAMEY U.S. AIR FORCE BASE)
C A R I B B E A N S E A
P U E R T O R I C O
SALINAS
TRAING AREA
A T L A N T I C O C E A N
FORT BUCHANAN
SAN JUAN
U. S. NAVAL STATION
ROOSEVELT ROADS
ENVIRONMENTAL DIV. (DPW)
O & M DIV. (DPW)
MASTER PLANNING DIV. (DPW)
ENERGY MANAGER (DPW)
PHYSICAL SECURITY (DES)
POLICE SERVICES (DES)
FIRE SERVICES (DES)
SAFETY OFFICER
FORCE PROTECTION (DPTMS)
NEC
LOGISTIC READINESS CENTER
DIGITAL SIGNATUREACTIVITY
R E
V
D A
T E
A
PP
L
IE
D B
Y
PROJECT MANAGER
CIVIL & ARCH. DESIGN
MECHANICAL DESIGN
ELECTRICAL & FIRE
PROTECTION DESIGN
GOV. REP.
PROJECT TEAM
DPW ENGINEERING
DIVISION
SHEET ID
T-101
SITE LOCATION
DPW
VEGA
GATE
BX
LAS CASAS
LAKE
LAS CASAS
LAKE
BORINQUINEERS
GATE
REPAIRS TO BUILDING 509 (SSMO) FOR ADDITIONAL
CERTIFICATION REQUIREMENTS - DPW-2023-007
FORT BUCHANAN, PUERTO RICO
MARIA A. LOPEZ
DIRECTOR OF
PUBLIC WORKS
LUIS E. TORRES
ENGINEERING DIV. CHIEF
APPROVED BY:
RECOMMENDED BY:
SHEET INDEX
SHEET # SHEET ID SHEET TITLE
1 T-101 TITLE SHEET, SITE MAP & SHEET INDEX
2 G-101 GENERAL NOTES, ABBREVIATIONS
3 C-101 EXISTING/DEMOLITION WORKS FLOOR PLAN & ELEVATIONS
4 SI-101 NEW LOADING DOCK AND FORKLIFT BATTERY CHARGING AREA FLOOR PLAN & ELEVATIONS
5 SI-102 NEW PLUMBING WORKS PLAN AND FORKLIFT BATTERY CHARGING AREA SECURITY GRILLS ELEVATIONS & DETAILS
6 S-101 NEW LOADING DOCK CONCRETE WORKS PLAN & SECTIONALS
7 S-102 LOADING DOCK AND FORKLIFT BATTERY CHARGING AREA METAL ROOF PLAN, ELEVATIONS & SECTIONALS
8 S-103 CORRIDOR CANOPY OVERHEAD PIPE SUPPORT ELEVATIONS, SECTIONALS & DETAILS
9 S-104 FREEZER AND COOLER FLOOR REPAIRS PLAN
10 FP-1 EXTERIOR CANOPY NEW FIRE PLAN
11 E-101 ELECTRICAL EXISTING/DEMOLITION WORKS FLOOR PLAN
12 E-102 ELECTRICAL NEW WORKS FLOOR PLAN
13 E-103 ELECTRICAL ADDITIONAL NOTES & PANEL SCHEDULES
14 M-101 MECHANICAL NEW WORKS FLOOR PLAN
15 M-102 MECHANICAL DETAILS & SECTIONALS
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text
PERIMETER RD.
AutoCAD SHX Text
BLDG 509
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
G E
N E
R A
L N
O T
E S, A B
B R
E V
IA
T
IO
N
S, L
E G
E N
D
SHEET ID
G-101
GENERAL NOTES
1. CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, MATERIALS, INSURANCES, SUPERVISION, INCIDENTALS, AND EVERYTHING NECESSARY TO MAKE ADDITIONAL REPAIRS TO BUILDING 509 SSMO OPERATIONS AND WORKS INDICATED IN THE SPECIFICATIONS SECTIONS AND DRAWINGS TITLED " REPAIRS TO BUILDING 509 (SSMO) FOR ADDITIONAL CERTIFICATION REQUIREMENTS - DPW -2023-007" IN ACCORDANCE WITH STATEMENT OF
WORK(SOW) AND CONTRACT PACKAGE DOCUMENTS.
2. CONTRACTOR SHALL PERFORM ALL WORKS INDICATED IN DRAWINGS IN ACCORDANCE WITH STATEMENT OF WORK(SOW) IN DIVISION 23 HEATING, VENTILATION, AND AIR CONDITIONING. ALL NEW AIR CONDITIONING EQUIPMENT SHALL BE LABELED ENERGY STAR AND COMPLY WITH MINIMUM EER = 12 AND SEER = 17.
3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE MOST CURRENT EDITION IN EFFECT AT THE TIME OF THE NOTICE TO PROCEED OF THE PROJECT OF ALL APPLICABLE CODES AND STANDARDS, INCLUDING BUT NOT LIMITED
TO:
I. THE INTERNATIONAL BUILDING CODE
II. NATIONAL ELECTRIC CODE
III. NATIONAL FIRE PROTECTION AGENCY REQUIREMENTS
IV. INSTALLATION DESIGN GUIDE
V. HVAC CODE
4. ALL WORK SHALL COMPLY WITH THE UNIFIED FACILITY CRITERIA (UFC) AND INDUSTRY STANDARDS AND UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS), EVEN THOUGH THE SPECIFICATIONS ARE NOT LISTED WITHIN THE
STATEMENT OF WORK (SOW). THE MORE RESTRICTIVE GUIDANCE PREVAILS.
5. CONTRACTOR SHALL PERFORM SELECTED DEMOLITION AND DISPOSITION INDICATED IN THE STATEMENT OF WORK (SOW), CONTRACT PACKAGE DOCUMENTS, AND USING DRAWINGS AND SPECIFICATIONS FOR REFERENCE AND
GOOD QUALITY OF WORKS.
6. CONTRACTOR SHALL PROVIDE LABOR EQUIPMENT, AND MATERIAL TO REPLACE EXISTING POWER SYSTEM INCLUDING THE ELECTRICAL WIRING AND CONDUITS REQUIRED, INCLUDING ANY/ALL INCIDENTAL RELATED WORK AS INDICATED ON DRAWINGS. CONTRACTOR SHALL PERFORM NEW ELECTRICAL WORK INDICATED IN THE SOW AND RELATED DRAWINGS IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS AND CURRENT CODES AND
STANDARDS.
7. CONTRACTOR SHALL PROVIDE FIRE PROTECTION SYSTEM EXTENSION ON THE NEW LOADING DOCK AND FORKLIFT BATTERY CHARGING STATION AREAS OF THE SSMO BUILDING (509.) CONTRACTOR SHALL INSTALL NEW FIRE SUPPRESSION SYSTEM TO EXTEND THE EXISTING SYSTEM FOLLOWING THE PROVIDED DRAWING TITLED "REPAIRS
TO BUILDING 509 (SSMO) FOR ADDITIONAL CERTIFICATION REQUIREMENTS."
LIST OF ABBREVIATIONS
A A.B.I. ACOUSTICAL BUTT INSULATION
A/C AIR CONDITIONING
AFF ABOVE FINISH FLOOR
AL, ALUM ALUMINUM
ALT ALTERNATE
AMP, A AMPERE
AP ACCESS PANEL
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
ARR ARRESTOR
AWG AMERICAN WIRE GAUGE
B B, BOT BOTTOM
BD BOARD
BLDG, B BUILDING
BW BOTH WAY
C C(#) CIRCUIT NUMBER
CC, CTC CENTER TO CENTER
CFM CUBIC FEET PER MINUTE
CKT CIRCUIT
℄ CENTERLINE
CLG CEILING
CMU CONCRETE MASONRY UNITS
CND, C CONDUIT
COL COLUMN
CONC CONCRETE
COND CONDUCTOR
CONN CONNECTION
CONST CONSTRUCTION
D D DEPTH, DEEP, DEGREE
OF CURVATURE
DET, DTL DETAIL
D, DIAM DIAMETER
DIM DIMENSION
DWG DRAWING
D PNL DISTRIBUTION PANEL
DN DOWN
E EA EACH
EF EACH FACE
EL, ELEV ELEVATION
ELEC ELECTRIC, ELECTRICAL
EMB EMBEDDED
EMT ELECTRICAL METAL TUBING
ETC ETCETERA
EW EACH WAY
EXIST, EX, E EXISTING
F F FARENHEIT
FDB FARENHEIT DRY BULB
FD FLEXIBLE DUCT
FFE FINISHED FLOOR ELEVATION
FIN FINISH
FL FLOOR, FLASHING
FT FOOT, FEET
FWB FARENHEIT WET BULB
G GA, G GAUGE
GALV GALVANIZED
GB GYPSUM BOARD
GI GALVANIZED IRON
GPM GALLONS PER MINUTE
GR GRADE
GRD GROUND
GW GROUND WATER
H H, HGT, HT HEIGHT
HEX HEXAGONAL
HP HORSEPOWER
I ID INSIDE DIAMETER,
INSIDE DIMENSION
IN INCH
IN C.W. INCH COLD WATER
J JB JUNCTION BOX
K KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L L LENGTH, LENGTH OF CURVE
LBS POUNDS
LED LIGHT EMITTING DIODE
LT LIGHT
M MAX MAXIMUM
MBH MEGA BRITISH HOUR
MECH MECHANICAL
MD MANUAL DAMPER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
N N, NW NORTH, NEW
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
O OD OUTSIDE DIAMTER
OPNG OPENING
OBD OUTSIDE BLADE DAMPER
P PL PLATE
PRELIM PRELIMINARY
PSI POUNDS PER SQUARE INCH
PVC POINT OF VERTICAL CURVE
PSF POUNDS PER SQUARE FOOT
R R RADIUS, RISER, RUBBER SHEATH
RR RETURN REGISTER
RG RETURN GRILLE
RE, REF REFERENCE, REFER TO
REINF REINFORCEMENT
REV REVISION
R RM ROOM
RLA RATED LOAD AMPERE
RTU ROOF TOP UNIT
S SCH, SCHED SCHEDULE
SD SPLITTER DAMPER
SECT SECTION
SHT SHEET
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STO STORAGE
STRUCT STRUCTURE, STRUCTURAL
SW SWITCH
T T TOP, TANGENT
3/P THREE POLE
TS TUBULAR STEEL
TON TONELATE
TYP TYPICAL
U UG UNDERGROUND
V V VENT, VOLT, VALVE
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
W W WIDTH, WASTE, WATER, WATT, WEST
W/ WITH
WP WATERPROOF, WEATHERPROOF
WT WEIGHT
X XFMR TRANSFORMER
SPECIAL SYMBOLS
∠ ANGLE
@ AT
& AND
XX° ANGLE, DEGREES
# NUMBER
Ø DIAMETER
3W THREEWAYS
D R
A W
N B
Y : C
. K U
G
LE
R
C H
EC
K
ED
B
Y
R
EC
O M
M
EN
D
ED
B Y
: L U
IS
E
. T O
R R
ES
A
PP
R O
V
ED
B Y
: A N
IB
A
L N
EG
R
O N
D
ES
IG
N
ED
B
Y
R
EV
IS
IO
N S
N O
D
A
TE
D
ES
C R
IP
TI
O N
A
PP
R O
V A
L
5 5
8 7
1 1 1 1 1
"A"
"B" 4"9
COOLER AND FREEZER
7 8
3 3 3
1 1 1
6 9
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
E X
IS
T
IN
G
/D E
M O
L
IT
IO
N
W O
R K
S
FL
O O
R
PL
A N
A N
D E
L E
V A
T
IO
N S
SHEET ID
C-101
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T
O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
DEMOLITION NOTES(THIS SHEET ONLY)
1 DEMOLISH AND DISPOSE CONCRETE FLOOR SLAB, BEAMS, COLUMNS, WALLS
AND FOOTINGS OF LOADING CORRIDOR AND LOADING DOCK AREAS AS SHOWN
ON DRAWING(SEE SPECIAL NOTE I).
2 REMOVE AND DISPOSE EXISTING DOCK BUMPERS
3 REMOVE AND DISPOSE OF EXISTING RAILINGS AND FLOOR CORNER GUARD
ANGLES. COORDINATE DISPOSAL IN ACCORDANCE WITH LEAD ABATEMENT
REGULATIONS(SEE SPECIAL NOTE II). VERIFY LOCATION IN FIELD.
4 DEMOLISH AND DISPOSE OF DEBRIS OF CONCRETE PAVEMENT PADS.
5 CUT DOWNSPOUT AND INSTALL ELBOW TO DIRECT RAINWATER OVER THE NEW
METAL ROOF.
6 REMOVE AND DISPOSE OF ASPHALT PAVEMENT AND SUB-BASE STARTING AT A
DEPTH OF 1'-0" AT "A" AND ENDING AT A DEPTH OF 2'-1" AT "B."
7 REMOVE AND DISPOSE OF HOLLOW METAL DOOR AND FRAME. RETURN
HARDWARE TO THE GOVERNMENT. INSTALL TEMPORARY SHORING ON THE
OPENING UNTEL. SEE SHORING DETAIL AT BOTTOM OF THIS SHEET.
8 DEMOLISH SECTION OF WALL TO CREATE THE OPENING FOR A NEW
ROLL-UP DOOR. INSTALL TEMPORARY SHORING TO SUPPORT THE OPENING
UNTEL(SEE SPECIAL NOTE III). SEE SHORING DETAIL AT BOTTOM OF THIS SHEET.
9 REMOVE 4" OF EXISTING ASPHALT PAVEMENT ON THIS AREA
10 REMOVE PORTION OF STEEL RAILING AND DISPOSE OF ACCORDING TO LEAD
ABATEMENT REGULATIONS.
11 PREPARE AND CLEAN EXISTING FLOOR IN ACCORDANCE WITH SECTION 1.3.8,
PART A AND B OF THE SCOPE OF WORK.
12 REMOVE AND STORE ENTRANCE STEEL RAMPS.
13 REMOVE EXISTING STEEL PLATE FLOOR AND HANDOVER TO GOVERNMENT. ALL
OTHER FLOOR COMPONENTS TO REMAIN IN PLACE.
SPECIAL NOTES(THIS SHEET ONLY)
I EXISTING LOADING DOCK SHALL BE DEMOLISHED AND DISPOSED OF, TAKING IN
CONSIDERATION TO AVOID DAMAGING EXISTING WALL AND STORM SEWER BOX
CULVERT. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND SHALL REPAIR
AT NO COST TO THE GOVERNMENT.
II EXISTING PAINT ON RAILINGS AND FLOOR CORNER GUARD ANGLES TESTED
POSITIVE FOR LEAD BASED PAINT (LBP) IN MARCH 2015(REFER TO SURVEY
REPORT BY ZIMMETRY ENVIRONMENTAL CORP., TEL: (787)376-9010.
III CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY SHORING BEFORE
DEMOLITION OF THE WALL. TEMPORARY SHORING SHALL BE REMOVED ONCE
THE NEW OPENING IS COMPLETE.(SEE DOOR OPENING ELEVATION AND SECTION
BELOW).
21'-0" 20'-O"
'-0
"A
60'-0"
12'
10'
12'
8'
12'
7'-11"
15'-0" 3'-8"
4'-7 " 24'-
8"
1'-6"
15'-0"
25'- 6"
16'-2" 21'-0" 19'-6"
9' -4
9' -4
43'-7"
30'-0"
10'
2' -1 1"
2' -1 1"
2' -1 1"
4" X 6" STEEL PIPE
STEEL SHORES JACK
STEEL SHORES JACK
5'-0"
10'-0"
8' -0
EXISTING BUILDING LOADING DOCK FLOOR PLAN
SCALE: 3/32"=1'-0"
EXISTING BUILDING NORTH ELEVATION
SCALE: 3/32"=1'-0"
EXISTING BUILDING SOUTH ELEVATION
SCALE: 3/32"=1'-0"
DOOR OPENING - TEMPORARY
SHORING ELEVATION
SCALE: 1/4"=1'-0"
DOOR OPENING - TEMPORARY
SHORING SECTION
SCALE: 1/4"=1'-0"
DEMOLISH CONCRETE
DEMOLISH ASPHALT
DEMOLISH ASPHALT(4" DEPTH)
CLEAN AND PREP FLOOR
DEMOLISH WALL
DEMO LEGEND
N
N
"B
N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
5 5 5 5 5 5 5 5 5 5 3B
3A
3A
3A
3A
3A
1 1 1 1 1
2 2 2 2 2
22222
1 7
3B
8' -6
8' -6
5' -0
4' -0
6'-6"
30'-0" 60'-0"
'-0
'-9
'-0
'-6
25'-0" 29'-0" 25'-0" 25'-0"
'-0
'-0
'-0
3' -0
6"
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
N E
W L
O A
D
IN
G D
O C
K A
N D
F O
R K
L
IF
T B
A T
T E
R Y
C H
A R
G
IN
G A
R E
A
FL
O O
R P
L A
N A
N D
E L
E V
A T
IO
N
S
SHEET ID
SI-101
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
NEW WORKS NOTES(THIS SHEET ONLY)
1 NEW LOADING DOCK AREA CONCRETE SLAB FLOOR OVER NEW BACK FILL MATERIAL AND NEW
RETAINING WALL. SEE STRUCTURAL DRAWING S-101 FOR DETAILS. CONCRETE TO BE SEALED AND
BROOM FINISHED.
2 NEW 36" HEIGHT CONCRETE PEDESTALS TO SUPPORT CORRIDOR ROOF STEEL COLUMNS. SEE CORNER
GUARD DETAILS BELOW. INSTALL CORNER GUARD EDGE PROTECTOR. PAINT WITH ONE COAT OF
TRAFFIC YELLOW PAINT. SEE CORNER GUARD DETAIL AT BOTTOM OF SI-101 FOR DETAILS.
3 NEW TWO WAVE GUARD RAILS SYSTEM WITH 60" GALVANIZED STEEL POSTS SIMILAR OR EQUAL TO MCMASTER-CAR, MODEL 9181T25. GAURDRAILS TO BE PAINTED TRAFFIC YELLOW. SEE GUARD RAIL
ELEVATION AND SECTION 3A AND 3B BELOW.
4 CONSTRUCT NEW DOCK LEVELERS PIT IN CONCRETE SLAB WITH CORNER GUARD ANGLES
3" x 3" x 1/4". SEE SHEET S-101 FOR MORE DETAILS.
5 NEW 42" HEIGHT GALVANIZED STEEL RAILINGS IN 1.5" DIAM. SCHEDULE 40 PIPE WITH TWO
HORIZONTAL PIPES AND VERTICAL PIPES AT A MAXIMUM DISTANCE OF 5'-0".
6 NEW REMOVABLE SECTION OF 42" GALVANIZED STEEL RAILINGS IN 1.5" DIAM. AND 40 GAUGE PIPE
WITH TWO HORIZONTAL PIPES AND VERTICAL PIPES AT A MAXIMUM DISTANCE OF 5'-0".
7 NEW CONCRETE SLAB RAMP, 4,000 PSI, WITH TWO LAYERS OF REINFORCEMENT STEEL BARS #5 AT
10" CENTER TO CENTER EACH WAY. SEE DETAIL 1, 2 & 5 ON SHEET S-101 FOR REFERENCE.
8 SUPPLY AND INSTALL NEW ROLL-UP DOOR 8' x 8' SIMILAR OR EQUAL TO COOKSON ROLL UP DOORS MODEL ESD10. CONTRACTOR SHALL INSTALL MC8 HOT ROLLER STEEL CHANNEL TIE COLUMNS TO SUPPORT THE LINTEL CHANNEL. STEEL CHANNEL SHALL BE COATED WITH RED-OXIDE PRIMER AND TWO COAT OF ENAMEL PAINT. SEE ROLLUP DOOR OPENING DETAIL AT BOTTOM OF THIS SHEET FOR
ANCHOR LOCATIONS.
9 SUPPLY AND INSTALL AIR CURTAIN SIMILAR OR EQUAL TO MODEL ETD-2-96E BY POWERED
AIRE INC. INSTALL PLASTIC PVC STRIP DOORS EQUAL OR SIMILAR TO CHASE DOORS MODEL #121203.
10 SUPPLY AND INSTALL SAFETY TRAILERS CAST-IN WHEEL ALIGNMENT GUIDE SIMILAR OR EQUAL TO ARMO ACCESSORIES MODEL ARCI. THIS GUIDE SHALL BE INSTALLED TO DIRECT THE CONTAINER
WHEELS TO THE LOADING DOCK LEVELERS.
11 SUPPLY AND INSTALL EMERGENCY SHOWER/EYEWASH STATION SIMILAR OR EQUAL TO ULINE MODEL H-6618, COORDINATE WITH COR AND TENANT FOR EXACT LOCATION. SEE SHEET SI-102 FOR PIPING
AND SEWER DETAILS.
12 SUPPLY AND INSTALL 4 PALLET CAPACITY RACK SYSTEM. SEE SCOPE OF WORK FOR MORE DETAILS.
13 8" DIAM. GALVANIZED STEEL PIPE 60" HEIGHT FILLED WITH CONCRETE. CONCRETE BASE SHALL BE 24" x 24" x 24". SEE PIPE BOLLARD DETAIL BELOW.
14 5 EACH VERTICAL DOCK BUMPERS 12" x 4" x 10" MADE FROM SUPER-TOUGH TRUCK TIRE MATERIAL.
FOR FINAL INSTALLATION LOCATION CONTRACTOR SHALL COORDINATE WITH COR.
15 CONCRETE STAIR WITH STEEL RAILINGS AND STAIR NOSING. SEE S-101, SECTION 6/S-101 FOR MORE DETAILS. HANDRAILS ARE 42" FROM TOP OF STEP AND EXTEND MIN 12" FROM EDGE OF LAST STEP.
STAIRS WILL BE A MINIMUM OF 36" WIDE FROM INSIDE OF HANDRAIL TO INSIDE OF OPPOSITE
HANDRAIL.
16 APPLY EPOXY RESIN FLOOR FINISH TO THE WAREHOUSE AREA. SEE SCOPE OF WORK ITEM 1.3.8 FOR
FLOOR PREPARATION AND PRODUCT DESCRIPTION.
17 REINFORCE EXISTING FLOOR. SEE DETAILS ON SHEET S-104.
18 INSTALL 412" DOCK CHAIN BOLLARD BARRIER, 42" HIGH SIMILAR OR EQUAL TO VESTIL
MODEL # DCBB-42-4.5. SEE ELEVATION E-1 ON SHEET S-102.
NEW BUILDING LOADING DOCK FLOOR PLAN
SCALE: 3/32"=1'-0"
NEW LOADING DOCK ELEVATION
SCALE: 3/32"=1'-0"
NEW BATTERY CHARGING AREA ELEVATION
SCALE: 3/32"=1'-0"
TWO WAVE GUARDRAIL WALL PROTECTION ELEVATION AND SECTION
SCALE: 1/4"=1'-0"
TWO WAVE GUARD RAIL LOADING DOCK ELEVATION AND SECTION
SCALE: 1/4"=1'-0"
ROLL UP DOOR OPENING DETAIL
SCALE: 14"=1'-0"
CORNER GUARD DETAIL
SCALE: 3/8"=1'-0" PIPE BOLLARD DETAIL
SCALE: 3/8"=1'-0"
60'-0"
NEW GUTTER WITH
DOWNSPOUT
NEW GALVALUME FASCIA
EXISTING PAVEMENT LEVEL
RAMP S = 1.80%
NEW GALVALUME CANOPY
NEW 4" FLASHING
NEW GALVALUME CANOPY
NEW GUTTER WITH
DOWNSPOUT
NEW GALVALUME FASCIA
NEW GUTTER WITH
DOWNSPOUT
EXISTING GALVALUME WALL EXISTING GALVALUME WALL EXISTING GALVALUME WALL EXISTING GALVALUME WALL
EXISTING GALVALUME ROOF
NEW GALVALUME
FASCIA, NEW GUTTER
AND DOWNSPOUT
NEW GALVALUME
FASCIA, NEW GUTTER
AND DOWNSPOUT
4"X4"X1/2" GALVANIZED STEEL ANGLE BOLTED
TO WALL WITH 6"X5/8" WEDGE AND 4.5"X3/8"-16 HEX
BOLTS, HOT DIPPED GALVAN. STEEL WITH WASHER
&NUTS TO SUPPORT THE 4"X4" COLUMN.
CONCRETE GUTTER
TRAFFIC DIRECTION
12-1/4" HEIGHT TWO
WAVE GUARD RAIL 1/8"
THICKNESS 2'
-6
4"X6"X30"
GUARD
RAIL POST
TWO WAVE GUARDRAIL
12-1/4" HEIGHT
X1/8"THICKNESS
1/2"X10"X10"
STEEL PLATE
V A R
IE
S
3' -6
1' -6
6"
60" HEIGHT 4" WIDTH 6" DEPTH
POST FOR RAIL EMBEDDED IN
10" THICK RETAINING WALL
12-1/4" HEIGHT TWO
WAVE GUARD RAIL
1/8"THICKNESS
4'X4"X1
2" STEEL
ANGLE CORNER
GUARD
1' 2'-4" 2'-4" 2'-4"
6" LINTEL STEEL
CHANNEL
12"X8" CONCRETE
TIE COLUMN WITH
4 VERTICALS. #5 REBAR
AND #3 STIRRUPS
AT 8" C.T.C.
CORNER GUARD
ANGLE
(SEE DETAILS BELOW)
36" HEIGHT 3"X3"X3/8"
CORNER GUARD STEEL
ANGLE WITH NELSON
STUDS/DOWELS(TYP.)
CONCRETE ANCHOR
2" DIAM., 4" LONG
LOCATED AS SHOWN
12-1/4" HEIGHT TWO WAVE
GUARD RAIL 18" THICKNESS
1/2"X12" REBAR
DOWELS TO
CONNECT THE WALL
REINFORCEMENT
3"
3"
3"
5' -0 "3' -6
2' -0
2'-0"
NEW BATTERY
CHARGING AREA
3A
3B
CHANNEL
ANCHORS
NEW CONCRETE LOADING DOCK AREA
NEW CONCRETE LOADING DOCK RAMP
NEW WAREHOUSE EPOXY RESIN FLOOR
NEW PALLET RACK
NEW WORKS LEGEND
N
N
N
4EA 5/8"x4" WEDGE
ANCHOR BOLT
THROUGH STEEL PLATE,
INTO CONCRETE
C
C
B
SECTION OF EXPOSED PIPE BELOW
THE SLAB FLOOR AND BACK SIDE
OF BEAM
INSTALL "NOT AN EXIT" SIGN
SECTION OF EXPOSED PIPE
BELOW THE SLAB FLOOR
EXISTING 1 12"
PVC PIPE
ENDING WITH
P-TRAP
1 2 2 2
4 4
CONCRETE
HEADWALL
4 4
3 3
4 44
CONCRETE HEADWALL
FORKLIFT BATTERY
CHARGING AREA
EXISTING BOX CULVERTEXISTING BOX CULVERT
A
90'-3"42'-10"
D
'-4
25'-0"
50'-0"
5' -5
7' -0
'-0
9' -9
28'-5"
3 3
55 5
EXISTING BOX CULVERT
EXISTING BOX CULVERT
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
N E
W P
L U
M B
IN
G
W O
R K
S
PL
A N
A N
D
FO
R K
L
IF
T B
A T
T E
R Y
C H
A R
G
IN
G
SE
C U
R
IT
Y G
R
IL
L E
E L
E V
A T
IO
N
S A
N D
D E
T A
IL
S
SHEET ID
SI-102
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T
O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
NEW STORM SEWER WORKS NOTES
1 POINT OF CONNECTION OF NEW 24" DIAM. CORRUGATED HDPE STORM WATER FROM EAST CULVERT TO WEST
BOX CULVERT, PROTECTED AND FIXED IN PLACE WITH CONCRETE HEAD WALL
2 NEW 24" DIAM. CORRUGATED HDPE STORM SEWER DUAL WALL PIPE SIMILAR OR EQUAL TO NEAT DISTRIBUTING
PRODUCTS PART #HDPE2420R.
3 NEW 4" DIAM. PVC SDR 35 PIPE SIMILAR OR EQUAL TO CHARLOTTE PIPE MANUFACTURING DISTRIBUTING
PRODUCTS, PART # S/M060040600FP.
4 DOWNSPOUT SHALL BE CONNECTED TO THE PVC PIPES WITH 4" DOWNSPOUTS TO DRAIN PIPES ADAPTER 3" X 3" X
4" SIMILAR OR EQUAL TO UNIVERSAL DRAINAGE ADAPTERS MANUFACTURERS.
5 PVC PIPE SHALL BE CONNECTED TO THE TOP OF THE HDPE PIPE WITH 4" PVC ADAPTOR SIMILAR OR EQUAL TO
SEKO-BETA TECHNOLOGY, CANNON WATER TECHNOLOGY INC.
6 5" HEIGHT BY 5" WIDE(INTERIOR) TRENCH DRAIN INTEGRATED IN THE CONCRETE SLAB RAMP INCLUDE 1.5" X 1.5" X 3/8" STEEL ANGLE FRAME ASTM A36, TRENCH DRAIN GRILL SHALL BE HEAVY DUTY SIMILAR OR EQUAL TO
6951M2-8", 1.5" DEEP X 24" BY EAST JORDAN MANUFACTURERS.
7 CONTRACTOR SHALL INCLUDE CLEANING THE EXISTING BOX CUVLERT FROM BLDG 507 WEST SECTION TO BLDG
511 EAST SECTION(SEE DRAWING FOR REFERENCE AND CULVERT LENGTH).
8 FREEZER AND COOLER CONDENSING WASTEWATER PIPE (1.5" DIAM.) EXTENSION FROM EXISTING P-TRAP TO EXISTING CONCRETE BOX CULVERT. THE DEEPENING OF THE EXCAVATION WILL BE NECESSARY TO PENETRATE THE WALL OF THE BOX CULVERT AS HIGH AS POSSIBLE(CONSIDER 6" MAXIMUM DEPTH).
9 AIR CONDITIONING EXISTING CONDENSING WATER PIPE(3/4" DIAM.) EXTENSION TO EXISTING CONCRETE BOX CULVERT. LEAVE THE EXISTING PIPE EXPOSED AND PLACE THE NEW EXTENSION PIPE UNDERGROUND WITH TWO ELBOWS. THE DEEPENING OF THE EXCAVATION WILL BE NECESSARY TO PENETRATE THE WALL OF THE BOX
CULVERT AS HIGH AS POSSIBLE(CONSIDER MAXIMUM DEPTH OF 6").
NEW BUILDING LOADING DOCK FLOOR PLAN
SCALE: 3/32"=1'-0"
NEW STORM SEWER PIPE
ON EXISTING BOX CULVERT
SCALE: NOT TO SCALE
BATTERY CHARGING AREA SECURITY GRILL FENCE
NORTH ELEVATION
SCALE: 3/16" = 1'-0"
TRENCH DRAIN INTEGRATED
IN THE RAMP FLOOR SLAB
SCALE: NOT TO SCALE
NEW 6' REINFORCED CONCRETE
HEADWALL AT HDPE PIPE AND BOX
CULVERT CONNECTION
SCALE: NOT TO SCALE
NEW POTABLE WATER WORKS NOTES
A NEW STAINLESS STEEL SERVICE SINK (INSTALLATION ONLY, OWNER SHALL SUPPLYTHE SINK). CONTRACTOR SHALL INCLUDE MATERIALS FOR WASTEWATER DRAINAGE TO INCLUDE STRAINERS, DOUBLE P-TRAP, 8" ADJUSTABLE CENTER WALL MOUNT FAUCET SIMILAR OR EQUAL TO BK RESOURCES BKF-VSMPR-WB-AF10-G 8" C/C, TWO HEAVY DUTY ANGLE
VALVE AND TWO FLEXIBLE BRAIDED STAINLESS STEEL FAUCET SUPPLY LINE.
B CONNECT 1" DIAM. POTABLE WATER COPPER PIPE TYPE K NEAR WATER METER AT WEST SIDE OF BUILDING INSTALL NEW 1" BRASS BALL VALVE. CONTINUE UNDER GROUND AS INDICATED ON DRAWING, ATTACH THE EXPOSED SECTION TO THE EXTERIOR CORRIDOR FLOOR SLAB BEAM(INTERIOR SIDE) WITH 1-5/8" X 7/8" CHANNEL SIMILAR OR EQUAL TO UNISTRUT AND 5/8" CUSH-A-CLAMP CHANNEL PIPE CLAMP ELECTRO GAL FINISH AT 4'-0" MAXIMUM DISTANCE CENTER
TO CENTER.
C UNDERGROUND PIPE INSTALLATION REQUIRES EXCAVATION SECTION 2'-0" DEEP AND NOT LESS THAN 6" WIDE, USE SAND BEDDING MATERIAL TO PROTECT THE PIPE 4" MINIMUM THICK(UP AND DOWN PIPE). USE EXISTING MATERIAL EXCAVATED TO BACKFILL. THE PIPE SECTION THAT CROSSES THE STORM SEWER BOX CULVERT SHALL CROSS BELOW
BOX CULVERT.
D NEW EMERGENCY SHOWER/EYE WASH STATION SIMILAR OR EQUAL TO BRADLEY S19-310. THE POTABLE WATER PIPE SHALL BE INSTALLED THROUGH THE EXTERIOR CONCRETE CORRIDOR FLOOR, CONTRACTOR SHALL USE CORE DRILL
TO OPEN HOLE AT FLOOR TO PASS WATER PIPE AND DRAIN.
NEW SANITARY SEWER PIPE WORKS NOTES
NEW EMERGENCY SHOWER/EYE WASH STATION WASTEWATER DISCHARGE SHALL BE
THROUGH THE EXTERIOR CONCRETE CORRIDOR FLOOR, CONTRACTOR SHALL USE CORE
DRILL TO OPEN HOLE AT FLOOR TO PASS THE WASTEWATER PIPE. THE WASTEWATER
SHALL BE DIREST TO THE STORM SEWER OPEN CHANNEL LOCATED UNDER THE
EXTERIOR CORRIDOR SLAB FLOOR. VERIFY EXACT LOCATION WITH BUILDING TENANT
AND COR BEFORE INSTALLATION.
NEW 2" DIAM. PVC PIPE FOR SINK WASTEWATER DRAINAGE, PIPE SHALL BE INSTALLED
INSIDE THE NEW EXTERIOR CORRIDOR SLAB FLOOR. THE EXPOSED SECTION SHALL BE
ON INTERIOR OF THE WALL WHERE THE SINK P-TRAP WILL BE CONNECTED. PROVIDE
CLEAN-OUT ON SLAB FLOOR AS SHOW ON DRAWING.
FOR SINK WASTEWATER CONNECTION, CONTRACTOR SHALL USE THE EXISTING 4" DIAM.
CLEAN OUT LOCATED AS SHOWN ON DRAWING, USING 4" ABS MALE ADAPTER HUB X
MIPT AND PIPE REDUCING FROM 4" TO 2" WITH REDUCER BUSHING. EXPOSED PIPE SHALL
BE PROTECTED BY CONCRETE, SEE STATEMENT OF WORK FOR DETAILS.
NEW BATTERY CHARGING AREA SECURITY GRILL
FENCE WORKS NOTES
(a) SECURITY FENCE SHALL BE FABRICATED WITH 18"" GAUGE GALVANIZED STEEL PIPE.
(b) VERTICAL PIPES SHALL BE 1" DIAM. PIPE WELDED TO TOP AND BOTTOM HORIZONTAL PIPE AND CROSSING THROUGH HORIZONTAL MIDDLE PIPE(3" X 2" RECTANGULAR PIPE BETWEEN 4" X 4" STEEL COLUMNS.)
SEE NORTH ELEVATION FOR LOCATION.
(c) HORIZONTAL PIPES(TOP, BOTTOM AND MIDDLE) SHALL BE 3" X 2" RECTANGULAR.
(d) CONTRACTOR SHALL INSTALL VERTICAL 3" X 2" RECTANGULAR PIPE BETWEEN 4" X 4" STEEL
COLUMNS. ANCHORED TO THE WALL USING WEDGE ANCHOR BOLTS. SEE NORTH ELEVATION.
(e) VERTICAL PIPES SHALL BE INSTALLED AT THE MAXIMUM OF 4" C.T.C. SPACING
(f) THE HORIZONTAL FENCE PIPE SHALL BE FULL WELDED TO THE 4" X 4" STEEL COLUMNS AS WELL AS THE
3" X 2" HORIZONTAL PIPE
(g) DOUBLE GATE SHALL OPEN TO THE EXTERIOR OF THE CHARGING BATTERY AREA. SEE EAST AND WEST
ELEVATIONS ON THIS SHEET FOR DOUBLE GATE LOCATION AND NOTES.
(h) ALL WEDGE BOLTS TO ANCHOR THE GALVANIZED PIPES SHALL BE HOT-DIP GALVANIZED OR SAME
MATERIAL AS PIPES BEING ANCHORED.
(i) SECURITY FENCE SHALL INCLUDE ONE COAT OF SHOP-PRIMER AND TWO COATS OF ENAMEL PAINT FOR
ALL GALVANIZED PIPES.
(j) TO WELD ALL GALVANIZED MATERIAL, CONTRACTOR SHALL PREP PIPES FOR WELD BY REMOVING ZINC COATING(ON SECTION TO BE WELDED), SELECT THE RIGHT FILLER/ELECTRODE, AND MAKE A FULL WELD
TO ALL PIPES AND PLATE CONNECTIONS.
BATTERY CHARGING AREA SECURITY GRILL FENCE
WEST ELEVATION
SCALE: 3/16" = 1'-0"
BATTERY CHARGING AREA SECURITY GRILL FENCE
EAST ELEVATION
SCALE: 3/16" = 1'-0"
'-4
BLDG 507
COOLER &
FREEZER
BLDG 511
29'-0"
IIIII
III
II
I
MAKE 4" DEPTH CORE-DRILL AND SET
VERTICAL PIPE IN CONC.WITH
NON-SHRINK GROUT.WELD EXISTING
RAILING TO NEW GALVANIZED
VERTICAL RAIL AND ELBOW.
(BOTH SIDES)
ANCHORED TO THE WALL
WITH FLAT HEAD HOT DIP
GALVANIZED WEDGE BOLT
SEE NOTE (e).
ANCHORED TO THE WALL
WITH 3-7" X 5/8" FLAT HEAD
HOT DIP GALV. WEDGE BOLT
SEE NOTE (e)
GALV. STEEL GRILL WITH 1" DIAM.
VERTICAL ELEMENTS AT 4" MAX
SPACING-3 HORIZONTAL RECTANGULAR
BARS 3" X 2". ALL GALVANIZED PIPE
SHALL BE 1/8" GAUGE, FULL WELDED.
GRILL SHALL BE ANCHORED TO STEEL
COLUMNS.
9'-6"
GALV. STEEL DOUBLE GATE WITH 1"
DIAM. VERTICAL PIPES AT 4" MAX.
SPACING. FRAME AND MIDDLE
RECTANGULAR BARS 3" X 2". ALL GALV.
PIPE SHALL BE 1/8" GAUGE,
FULL WELDED. THE DOUBLE GATE SHALL
INCLUDE 6 - 3" BALL BEARING
HINGES.TWO 5/8" X 24" DROP ROD WITH
PADLOCK(TOP AND BOTTOM) AND A 10"
SLIDING BOLT GATE LATCH
GALVANIZED STEEL GRILL WITH 1" DIAM. VERTICAL
ELEMENTS AT 4" MAX. SPACING. THREE HORIZONTAL
RECTANGULAR BARS 3" X 2". ALL GALV. PIPES SHALL
BE 1/8" GAUGE TUBE FULL WELDED. THE GRILL SHALL
BE ANCHORED TO STEEL COLUMNS.
3" X 2" X 1/8" GALVANIZED STEEL PIPE
ANCHORED TO THE WALL WITH
8" X 1/2" HOT DIP GALVANIZED
WEDGE BOLT(SEE NOTE d).
1" COPPER PIPE TO
EYEWASH STATION
MOUNTED BEHIND
COLUMNS, BELOW SLAB
FLOOR
1" COPPER PIPE
BELOW SLAB,
SEE NOTE D
TO EMERGENCY
EYEWASH STATION
N
N
N
1" COPPER PIPE FOR NEW EMERGENCY
EYE WASH STATION. EXPOSED BELOW SLAB
FLOOR, MOUNTED BEHIND COLUMNS.
N
NEW HDPE PIPE
NEW FEATURE (SEE NEW WORKS NOTE)
NEW WORKS LEGEND
I
EXISTING
BOX
CULVERT
91' - 11" 90' - 6"
CM DOCK LEVELER PIT DIMENSIONS
PIT LENGTH DIMENSION "A" 9'-3"
PIT WIDTH DIMENSION "B" 6'-1"
PIT DEPTH REAR DIMENSION "C" 1'-11 1/2"
PIT DEPTH
FRONT DIMENSION "D" 2'-0"
CURB ANGLE
FRONT & REAR DIMENSION "E" 6'-7"
CURB ANGLE
SIDE DIMENSION "F" 9'-0"
CURB ANGLE
BUMPER DIMENSION "G" 1'-9"
CURB ANGLE
BUMPER DIMENSION "H" 1'-9"
A
A
4" WIDTH x 3" MINIMUM
DEPTH CONTROL JOINT(CJ)
3' -0
1 1
3'
6"
1'-0"
3' -6
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
N E
W L
O A
D
IN
G D
O C
K C
O N
C R
E T
E W
O R
K S
PL
A
N A
N D
S E
C T
IO
N
S
SHEET ID
S-101
D R
A W
N B
Y : C
. K U
G
LE
R
C H
EC
K
ED
B
Y
R
EC
O M
M
EN
D
ED
B Y
: L U
IS
E
. T O
R R
ES
A
PP
R O
V
ED
B Y
: A N
IB
A
L N
EG
R
O N
D
ES
IG
N
ED
B
Y
R
EV
IS
IO
N S
N O
D
A
TE
D
ES
C R
IP
TI
O N
A
PP
R O
V A
L
NEW BUILDING LOADING DOCK FLOOR PLAN
SCALE: 3/16"=1'-0"
ANCHOR LAYOUT FOR CORNER GUARD ANGLE
SCALE: 3/16"=1'-0"
SECTION 1/S-101
SCALE: 3/8"=1'-0"
SECTION 3/S-101
SCALE: 3/8"=1'-0"
SECTION 2/S-101
SCALE: 3/8"=1'-0"
SECTION 4/S-101
SCALE: 3/8"=1'-0"
SECTION 5/S-101
SCALE: 3/8"=1'-0"
SECTION 6/S-101
SCALE: 3/8"=1'-0"
'-0
60'-0" 29'-0"
30'-0"
'-0
SAME ELEVATION AS
EXISTING DOCK RAMP
(ACTUAL 2'-11")
"E" "C"
"F" "A"
"E"
"D"
"H"
"G"
3" 1'-0" 1'-0"
CONCRETE ANCHOR, 1/2" DIAM., 6" LONG, LOCATED AS SHOWN
3"
3"
1/ 4"
4" X 4" X 1/2" CORNER
GUARD ANGLE EMBEDDED
ON RETAINING WALL NEW 6" THICK REINFORCED
CONC. SLAB FLOOR, 3500 PSI
AND #4 @10" BOTH WAYS
EXPANSION JOINT
MATERIAL, SEE NOTE
11, SHEET S-101
INSTALL 6 MIL
VAPOR BARRIER
NEW 24" STORM
SEWER PIPE6 #5 CONTINUOUS
REBAR AND #4 @12"
BUILDING EXISTING
FOOTING
AND RETAINING WALL
EXPANSION JOINT
MATERIAL.
SEE NOTE 11,
SHEET S-101
95% COMPACTED IN 12"
LAYERS. SELECTED FILL
MATERIAL
3'-0"
1' -0
"2' -6
M
IN
V A
R
IE
S
6"
6"
INSTALL 6 MIL
VAPOR BARRIER
EXISTING SUB-BASE
WELL COMPACTED
6" RETAINING WALL
CONCRETE, 3500 PSI
STEEL
REINFORCEMENT
#4@8" C.C. BOTH
WAYS
NEW CONCRETE PAVEMENT
1'-0"
3' -6
1' -0
3'-0"
3' -0
M
IN
V A
R
IE
S
NEW 6" THICK REINFORCED
CONCRETE SLAB FLOOR,
3500 PSI, #4 @10" BOTH WAYS
EXPANSION JOINT MATERIAL
SEE NOTE 11, SHEET S-101
INSTALL 6 MIL
VAPOR BARRIER
NEW 24" STORM
SEWER PIPE
6-#5 CONTINUOUS REBAR
AND #4 @ 12"
BUILDING EXISTING
FOOTING
AND RETAINING WALL
4-STEEL A36 L TYPE
ANCHOR BOLTS,
3/4" DIAM. X 20" LONG
6"
NEW 6" THICK REINFORCED
CONCRETE SLAB FLOOR AND
WALLS. 3500 PSI AND #4 @ 10"
BOTH WAYS
INSTALL 6 MIL
VAPOR BARRIER
EXPANSION JOINT MATERIAL
SEE NOTE 11, SHEET S-101
8" CAST-IRON STEEL
GRATING ON 1.5" X 1.5" X
1/4" STEEL ANGLE
6" RETAINING WALL,
CONCRETE, 3500PSI
WITH #4 @ 8" E.W.
REINFORCEMENT
95% COMPACTED IN 12" LAYERS,
SELECTED FILL MATERIAL
3'-0"
1' -0
8"
4' -0
4" X 6" X 60" GUARD
RAIL POST EMBEDDED
IN RETAINING WALL
4" X 4" X 1/2" GUARD
EDGE ANGLE EMBEDDED
ON RETAINING WALL
1/2" X 12" REBAR DOWELS
TO CONNECT TO THE WALL
REINFORCEMENT
10" RETAINING WALL
WITH #4 @ 8" E.W.
TWO WAVE GUARD RAIL
12 1/4" HEIGHT X 1/8" THICKNESS
NEW 6" THICK REINFORCED
CONCRETE SLAB FLOOR,
3500 PSI AMD #4 @ 10"
BOTH WAYS
INSTALL 6 MIL
VAPOR BARRIER
6-#5 CONTINUOUS REBAR AND
#4 @ 12"
EXISTING DRIVEWAY PAVEMENT
1' -0
3'-0"
3' -0
M
IN
V A
R
IE
S 3'
-6
10"
6" CONCRETE CURB, 3000 PSI WITH
#4 @ 12" E.W. REINFORCEMENT
VARIES FROM 13" TO 0"
NEW CONCRETE TRUCK RAMP,
4000 PSI WITH DOUBLE MATT
#5 REINFORCEMENT @ 12"
C.T.C.
EXISTING SUB-BASE,
WELL COMPACTED
INSTALL 6 MIL
VAPOR BARRIER
1' -0
EXISTING DRIVEWAY
PAVEMENT
3" 4"
EXISTING
DRIVEWAY
PAVEMENT
CONCRETE TIE BEAM,
3500 PSI WITH 4 #5 AND
#3 STIRRUPS AT 10" C.C.
CONCRETE STAIR,
3500 PSI WITH
#4 @ 8" E.W.
REINFORCEMENT
4" X 36" CAST ALUMINUM
SAFETY STAIR NOSING
TYP. AT ALL STEPS
7"
1'-0"
S-101
S-101
S-101
S-101
S-101
S-101
S-101
S-101
S-101
S-101
S-101
'-0
EXISTING
DRIVEWAY
PAVEMENT
LEVELER PIT DETAIL
SCALE: NOT TO SCALEA
N
SUBMERSIBLE SUMP PUMP DETAIL(TYP.)
SCALE: NOT TO SCALE
1' -0
1'
-0
V A
R
IE
S
1'-0"
SUMP PUMP PIT-TOP VIEW
1' -0
1'-0"
TO 24" HDPE PIPE
TO HDPE PIPE
10.4"
8.
7"
.8
NEW BUILDING LOADING DOCK GENERAL NOTES
1 EXCEPT FOR THE CONCRETE TRUCK RAMP, ALL NEW CONCRETE STRUCTURES SHALL BE 3,500 PSI (MINIMUM) AT 28 DAYS. STEEL REINFORCEMENT SHALL BE ASTM GRADE 60 (60 KSI). ALL MATERIALS SHALL COMPLY WITH THE
BUY AMERICA ACT.
2 FILL MATERIAL SHALL BE A-2-4 OR BETTER(AASHTO SOIL CLASSIFICATION SYSTEM). BACKFILL SHALL BE COMPACTED AT 95% MAXIMUM DRY DENSITY(MODIFY PROCTOR COMPACTION TEST, ASTM D1557) ON A 12"
THICK MAXIMUM LAYER.
3 CONTRACTOR SHALL REMOVE ALL DEBRIS, ORGANIC/UNSTABLE SOIL AND GRASS BEFORE DEPOSITING THE
SELECTED BACKFILL MATERIAL.
4 PROVIDE NEW DOCK LEVELERS PIT IN CONCRETE SLAB INCLUDING CORNER GUARD ANGLE(EQUIPMENT AND INSTALLATION SHALL BE BY OTHERS). SEE LEVELER PIT DETAIL A ON THIS SHEET FOR LOCATION AND
DETAILS.
NEW BUILDING LOADING DOCK KEY NOTES
1 INSTALL 6 MIL VAPOR BARRIER ON TOP OF FINISHED GRADE BEFORE NEW CONCRETE SLAB FLOOR AND
LOADING DOCK AREAS ARE POURED.
2 NEW CROSS GRATING SIMILAR OR EQUAL TO NDS CLASS C SLOTTED CAST IRON 8" X 24" SECTIONS ON STORM
SEWER CONCRETE CROSS GUTTER INTEGRATED IN THE DRIVEWAY CONCRETE SLAB. SEE SECTION 2 FOR MORE
DETAILS.
3 CONTROL JOINT(C.J.) WILL BE CUT IN A PERIOD OF 4-12 HOURS AFTER POURING OF CONCRETE OR
IMMEDIATELY ONCE THE CONCRETE REACHES NECESSARY HARDNESS.
4 CONTROL JOINT(C.J.) SHALL BE SEALED WITH HIGH-PERFORMANCE POLYURETHANE-BASED ELASTMERIC
SEALANT EQUAL OR SIMILAR TO SIKA FLEX 1A.
5 EXPANSION JOINT MATERIAL SHALL BE CLOSED-CELL POLYPROPYLENE FOAM PLY SIMILAR OR EQUAL TO NAMACO NOMAFLEX. SEAL WITH HIGH-PERFORMANCE POLYURETHANE-BASED ELASTMERIC SEALANT EQUAL
OR SIMILAR TO SIKA FLEX 1A. SEE SECTION DETAILS 1, 2, & 3 ON THIS SHEET.
6 CONSTRUCT 12" X 12" X 12" SUMP PUMP PIT. INSTALL SUBMERSIBLE SUMP PUMP SIMILAR OR EQUAL TO FRANKLIN ELECTRIC 5.5 SERIES, 1/4 HP, 8.7" WIDE X 10.4" LONG X 10.8" HEIGHT. SEE SUBMERSIBLE SUMP PUMP
DETAIL ON THIS SHEET.
3 3 3 3 3
'-3
3 3 3
1 1 2
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
L O
A D
IN
G
D O
C K
A N
D F
O R
K L
IF
T
B A
T T
E R
Y C
H A
R G
IN
G
A R
E A
M E
T A
L R
O O
F
PL
A N
, E L
E V
A T
IO
N
A N
D
SE
C T
IO
N
A L
S
SHEET ID
S-102
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
LOADING DOCK PLATFORM CANOPY PLAN
AND ELEVATIONS
SCALE: 3/32"=1'-0"
FORKLIFT BATTERY CHARGING AREA CANOPY
EAST & WEST ELEVATION
SCALE: 3/16"=1'-0"
FORKLIFT BATTERY CHARGING AREA
ROOF CANOPY PLAN(STRUCTURAL)
SCALE: 3/16"=1'-0"
LOADING DOCK CANOPY STRUCT. NOTES
a. PRE-ENGINEERING BUILDING(P.E.B.) STRUCTURE SIMILAR OR EQUAL TO ESCO
STEEL PRODUCT. STEEL STRUCTURE SHOP DRAWINGS SHALL BE CERTIFIED
BY A LICENSED ENGINEER ENSURING TO BE IN COMPLIANCE WITH FEDERAL
AND LOCAL CONSTRUCTION CODES.
b. ROOF DECK SHALL BE TYPE R 7/8", 22 GA. GALVALUME(36" COVERAGE)
PRE-PAINTED SIMILAR OR EQUAL TO ESCO STEEL PRODUCT IN EVERGREEN
COLOR(TYP.)
c. 5" RAIN GUTTER WITH 3"X4" DOWNSPOUT.
CORRIDOR CANOPY ROOF DECK MATERIAL
1 ROOF DECK SHALL BE TYPE R 7/8", 22 GA. GALVUALUME(36" COVERAGE)
PRE-PAINTED SIMILAR OR EQUAL TO ESCO STEEL PRODUCT IN EVERGREEN
COLOR(TYP.)
2 5" RAIN GUTTER ATTACHED TO ROOF PANELS WITH STRAPS AND 3EA 7/8" STITCH
AT 3"-0" C.C, 3"X4" DOWNSPOUT SUPPORTED BY STRAPS. THE DOWNSPOUT SHALL
BE CONNECTED TO PVC PIPE WITH DRAIN DOWNSPOUT ADAPTER, 3"X4".
3 LATERAL FASCIAS SHALL INCLUDE GALVALUME TYPE R ATTACHED TO 6" WALL
PURLIN GIRT WITH #12-14 X 1" SCREW(TYP). SEE ELEVATION FOR DETAIL
CORRIDOR CANOPY STRUCT. COMPONENTS
1 SQUARE CARBON STEEL TUBE 6" X 6" X 3/8" COLUMNS WITH STEEL PLATES 10" X
10" X 1/4" AT TOP AND BOTTOM(TYP.)
2 C-PURLIN BRIDGING 6" 14 GA AND C-PURLIN RAFTERS 8" 14 GA WELDED BACK
TO BACK(TYP.)
3 W6 X 15 BEAM FROM CORRIDOR CANOPY(SEE ELEVATION ON THIS SHEET).
FORKLIFT BATTERY CHARGING AREA ROOF CANOPY
STRUCT. COMPONENTS
1 ROOF DECK MATERIAL SHALL BE TYPE R 7/8", 22GA. GALVALUME(36" COVERAGE)
2 22 GAUE GALVALUME STRUCTURAL CORRUGATED ROOFING TYPE R PANEL
COLOR EVERGREEN OVER 6" X 2" GALVANIZED STEEL PURLINS BRIDGING AND
8" PURLINS RAFTERS, 14 GAUGE.
130'-6"
SLOPE SLOPE SLOPE
30'-0"
'-0
29'-0"
'-0
'-6
1' -6
30'-0"
'-7
39'-6"
4'-9"
'-7
4' -0
'-3
RIGID FRAME
RAFTER AND
COLUMN
32'-10"
30'-0"
4' -0
NEW GUTTER &
DOWNSPOUT
'-7
32'-10"
'-0
30'-0"
2' -1 1"
NEW GUTTER &
DOWNSPOUT
'-7
39'-6"
'-7
2' -1 1"
2' -1 1"
'-7
39'-6"
'-0
30'-0"
LOADING DOCK
TRUCK RAMP
LOADING DOCK
TRUCK RAMP
ELEVATION E-3 - LOADING DOCK
PRE-ENGINEERING STRUCTURE
SCALE: 3/32"=1'-0"
ELEVATION E-4 - LOADING DOCK
PRE-ENGINEERING STRUCTURE
SCALE: 3/32"=1'-0"
39'-6"
'-1 0"
ELEVATION E-1 - LOADING DOCK
PRE-ENGINEERING STRUCTURE
SCALE: 3/32"=1'-0"
ELEVATION E-2 - LOADING DOCK
PRE-ENGINEERING STRUCTURE
SCALE: 3/32"=1'-0"
LOADING DOCK PRE-ENGINEERING
STRUCTURE - BUILDING SECTION
SCALE: 3/32"=1'-0"
GALVALUME METAL ROOF(EVERGREEN)
WITH METAL FLASHING AND TRIMS
NEW GUTTER&
DOWNSPOUT
NEW GALVALUME FASCIA AT
THREE SIDES OF DECK USE C
TYPE PURLINGS TO SUPPORT
THE FRONT AND LATERAL
GALVALUME FASCIAS
EXISTING BUILDING
GALVALUME WALL
GALVALUME METAL
ROOF(EVERGREEN)
ON 6" C TYPE PURLINS
BRIDGING AND DOUBLE
(BACK TO BACK) 6" C TYPE
PURLINS RAFTERS
NEW GUTTER&
DOWNSPOUT
W6 X 15 STEEL BEAMS
WELDED TO STEEL
COLUMNS
6" X 6" STEEL COLUMNS
4 EA - A36 L TYPE STEEL
ANCHOR BOLTS, 3/4" DIAM.
X 20" LONG
6" X 6" X 3/8" GALVANIZED STEEL ANGLE
A36 ANCHORED TO THE WALL WITH 7" X 5/8"
WEDGE BOLT @ 30" C.T.C.
EXISTING BUILDING
GALVALUME WALL
3' -0
5' -6
1' -2
'-7
30'-0"
6" C TYPE PURLINS
BRIDGING(TYP.)
SLOPE
9'-8"
1' -3
2' -1 1"
7' -9
NEW GALVALUME
FASCIA AT THREE
SIDES OF DECK
4" X 4" X 3/8" GALVANIZED
STEEL COLUMNS
GALVALUME METAL ROOF(EVERGREEN)
ON 6" C TYPE PURLINS BRIDGING AND
DOUBLE (BACK TO BACK) 8" C TYPE
PURLINS RAFTERS. USE C TYPE PURLING
TO SUPPORT THE FRONT AND LATERAL
GALVALUME FASCIA
6" X 6" X 1/4" GALV. STEEL
PIPE WELDED TO STEEL
COLUMNS
4" X 4" X 3/8" GALVANIZED
STEEL COLUMNS
BRIDGING SHALL BE BOLTED
AND CONNECTED TO RAFTERS
WITH SUPPORT CLIP 4" X 1.5" X
5" GAUGE 12(TYP.)
6" X 6" X 3/8" GALVANIZED STEEL ANGLE
A36 ANCHORED TO THE WALL WITH
7" X 5/8" WEDGE BOLT @ 30" C.T.C.
4" X 4" X 12" GALVANIZED STEEL ANGLE
BOLTED TO WALL WITH 6" X 5/8" WEDGE
AND 4.5" X 38" - 16 HEX BOLTS, HOT DIP
GALVANIZED STEEL WITH WASHER AND
NUTS TO SUPPORT THE 4" X 4" COLUMN
8' HIGH OPENING FOR
ROLL-UP DOOR
EXISTING BUILDING GALVALUME WALL
12'-6" 12'-6" 12'-6" 12'-6" 12'-6" 9"
15'-0" 14'-0" 12'-6" 12'-6"
'-3
12'-6" 9"
2' -1 1"
9' -8
8' -6
1' -3
2' -1 1"
'-0
S-102
S-102
E-1 S-102
E-3 S-102
E-4 S-102
E-2 S-102
E-3
SI-3
E-2 S-3
E-1 S-3
E-4
SI-3
RIGID FRAME
RAFTER AND
COLUMN
N
LOADING DOCK CORRIDOR ROOF CANOPY PLAN
(DECKING MATERIAL)
SCALE: 1/8"=1'-0"
N
LOADING DOCK CORRIDOR ROOF CANOPY PLAN
(STRUCTURAL COMPONENTS BENEATH DECKING)
SCALE: 1/8"=1'-0"
FORKLIFT BATTERY CHARGER
ROOF CANOPY PLAN(DECK MATERIAL)
SCALE: 3/16"=1'-0"
N
TWO 8" C TYPE PURLINS
RAFTERS WELDED
BACK TO BACK(TYP.)
W 6 X 15 SUPPORTED BY 1/2" X 9" X 9"
STEEL PLATE ANCHORED TO WALL
WITH 4 EACH WEDGE BOLTS 1/2" X 5"
AND OVERHEAD SUPPORT PIPE(TYP.)
SEE SHEET S-103 FOR DETAILS
6" TYPE C PRE-PUNCHED PURLINS
BRIDGING(TYP.)
TWO 8" TYPE C PRE-PUNCHED
PURLINS RAFTERS, WELDED
BACK TO BACK(TYP.)
S-102
FORKLIFT BATTERY CHARGING AREA CANOPY
SECTION(TYP.)
SCALE: 3/16"=1'-0"
S-102
S-102
LOADING DOCK CORRIDOR CANOPY
EAST & WEST ELEVATION
SCALE: 3/16"=1'-0"
LOADING DOCK PRE-ENGINEERING
STRUCTURE - BUILDING SECTION
SCALE: 3/16"=1'-0"
S-102
N
NEW DOCK CHAIN BOLLARD BARRIER
NEW SECTION OF 24"
HANDRAIL
AutoCAD SHX Text
AutoCAD SHX Text
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
C O
R R
ID
O
R C
A N
O
PY
O V
E R
H E
A D
PI
PE
S U
PP
O
R T
E L
E V
A T
IO
N
S A
N D
S E
C T
IO
N
S
SHEET ID
S-103
D R
A W
N B
Y : C
. K U
G
LE
R
C H
EC
K
ED
B
Y
R
EC
O M
M
EN
D
ED
B Y
: L U
IS
E
. T O
R R
ES
A
PP
R O
V
ED
B Y
: A N
IB
A
L N
EG
R
O N
D
ES
IG
N
ED
B
Y
R
EV
IS
IO
N S
N O
D
A
TE
D
ES
C R
IP
TI
O N
A
PP
R O
V A
L
LOADING DOCK FLOOR PLAN
SCALE: 3/32"=1'-0"
STRUCTURAL GENERAL NOTES:
1 RAFTER SUPPORTED BY 2.5" DIAM. BLACK STEEL
PIPE SCHEDULE 40. CONNECTED BY WELDING
WITH DUAL GUSSET PLATE AT BOTH ENDS.
2 BEAM W6 X 15 BLACK STEEL SHALL BE
CONNECTED TO THE PRE-ENGINEERING COLUMNS
BY MECHANICAL METHODS. USE A325 5/8" DIAM. X
4" HEAVY HEX STRUCTURAL BOLTS WITH DOUBLE
WASHER AND NUT.
3 RAFTER BEAM W6 X 15 SHALL BE SUPPORTED BY
2.5" DIAM. PIPE WITH DUAL 1/2" THICK GUSSET
PLATES WELDED TO 1/2" THICK STEEL END
PLATES.
4 CONTRACTOR SHALL CUT THE GALVALUME WALL
WITH SCISSORS OR OTHER METHOD TO PREVENT
INSULATION FROM CATCHING FIRE. REPAIR
GALVALUME WALL PERFORATION WITH SAME
GALVALUME MATERIAL BOLTED WITH #12 X 1"
STEEL-BINDER METAL ROOFING SCREW AND SEAL
WITH SILICONE SEALANT. SEE SECTIONAL VIEW 1
& 2 AT BOTTOM OF THIS PAGE.
LOADING DOCK ROOF PLAN
SCALE: 3/32"=1'-0"
CORRIDOR SECTION 1/S-103
SCALE: 3/8"=1'-0"
CORRIDOR CANOPY OVERHEAD SUPPORT PIPE
SCALE: 3/4"=1'-0" PRE-ENGINEERING AND CORRIDOR ROOF SECTION 2/S-103
SCALE: 3/8"=1'-0"
DETAIL "A"
SCALE: 3/4"=1'-0"
DETAIL "B"
SCALE: 3/4"=1'-0"
29'-0" 39'-6"
'-1
0"
8' -6
" 10 '-0
'-7
9'
-8
9'-9"
W 6 X 15 RAFTER
STEEL BEAM
10" X 10" X 38" STEEL PLATE
ANCHORED TO WALL WITH
4- 4" X 58" HOT DIP GALV.
WEDGE BOLT
9' -8
9'
-1 1"
V A
R
IE
S
2'-2"
PRE-ENGINEERING ROOF
PRE-
ENGINEERING
FASCIA
3/4" 3/4"
4" 5"
8"
5/8"
2 1/2"
2' -2
S-103
6"
10"
9"
3/4"
1/2"
1/ 2"
6"
1' '-0
3/4"
1/2"
1/ 2"
A B
A
B
S-103 2
S-103
S-103
S-103
2 2
N N
DETAIL "C"
SCALE: 6"=1'-0" C
4"x4"GALVANIZED
FLASHING
NEW
CORRIDOR
DECK
SIKAFLEX
505 UV-1/2"
EXISTING WALL
DECK
2" OUTSIDE
CLOSURE STRIPS
D1
D1
D1 D1 D1 D1
D1
D1D1D1
D1
D2
EXISTING FLOOR PANELS
EXISTING CONCRETE FLOOR
EXISTING FLOOR PANELS
D-2
D-1 S-104
S-104
S-104
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
FR
E
E Z
E R
A N
D C
O O
L E
R F
L O
O R
R E
PA
IR
W O
R K
S
SHEET ID
S-104
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
FREEZER & COOLER FLOORPLAN - NEW SUPPORT PIPES AND ANCHOR BOLT LAYOUT NOTES
1 SUPPORT PIPES BELOW NEW STEEL PLATES SHALL BE 4" INTERIOR DIAM. STAINLESS STEEL SCH. 160 WITH 1/4" THICK STAINLESS STEEL PLATES
WELDED TO BOTTOM AND TOP OF THE PIPES. SEE PIPE SUPPORT DETAIL ON THIS SHEET.
2 PIPES AND OTHER SMALL SPACES RESULTING FROM THE CORE PREFORM SHALL BE FILLED WITH STYROFOAM INSULATION.
3 ATTACH SUPPORT PIPES WITH 1/4" X 6" CONCRETE ANCHOR SCREWS TO EXISTING CONCRETE FLOOR.
4 WELD CARBON STEEL ANGLES 5" X 5" X 1/4" TO THE STEEL RAMP AND INSTALL 1" INTERIOR DIAM. CARBON STEEL PIPES ON ENTRANCE FLOOR SECTION AS
SUPPORT FOR STEEL ANGLE(SEE SECTION 2 FOR MORE DETAILS).
5 BEFORE MANUFACTURING PIPE SUPPORT, CONTRACTOR SHALL CONFIRM THE SPECIFIC DEPTH OF THE CORE DRILLS PERFORMED TO CUT AND PREPARE SUPPORT PIES ACCORDINGLY WITH TOP AND BOTTOM PLATE AS SHOWN ON DETAILS. CONTRACTOR IS TO CONSIDER 4 1/4" IN THE PIPE SUPPORT HEIGHT
FOR CALCULATION OF MATERIALS.
FREEZER & COOLER FLOORPLAN - NEW STAINLESS STEEL PLATES LAYOUT WORK NOTES
1 USE ONE SILICONE TUBE(OR HEAVY DUTY LIQUID ADHESIVE) EACH 32 SF OF PLATE & SPREAD IN "S" SHAPE FORM
BETWEEN EXISTING STEEL PLATES AND NEW STEEL PLATES..
2 APPLY SILICONE BETWEEN ALL PLATE JOINTS AND AROUND ENTIRE WALL COVE PERIMETER.
3 STEEL PLATES SHALL BE ATTACHED TO FLOOR WITH STAINLESS STEEL #12 X 1.5" FLAT HEAD SELF DRILLING SCREWS @24" O.C. ALONG PERIMETER
POF PLATE AND @24" O.C. BOTH AREA OF STEEL PLATE.
SECTION 1/S-104
SCALE: 3/8"=1'-0"
SECTION 2/S-104
SCALE: 3/8"=1'-0"
3"
3' -9
4' -0
4' -0
4' -0
4' -0
1' -8 " 3"
22'-5" 3"
2'-2" 5'-0" 5'-0" 5'-0" 4'-9" 3" 3"
6'-3" 5'-0" 4'-9" 3"
4" 16'-6"
1' 2' 2' 2'
1' 1' 2' 2' 2'
1'
'-1 1"
3" '-5
3"
1/ 2"
4' -0
4' -0
4' -0
4' -0
4' -0
" 1/
2"
'-0
'-0
1/2"
2'-4" 10'-0" 10'-0"
22'-5" 16'-6"
6'-5 1/4" 10'-0"
'-1 1"
'-1 0"
22'-5"
4"
4"
CONTRACTOR WILL ENSURE THAT THE
NEW STEEL PLATE AND NEW ENTRY
ANGLE ARE AT THE SAME LEVEL
CARBON STEEL 1.0" DIAM PIPE
AS SUPPORT FOR THE STEEL
ANGLE
EXISTING STEEL RAMP WITH NEW
CARBON STEEL 5" X 5" X 1/4" ANGLE
SILICONE SEAL AT ALL WALL
PERIMETER
4" DIAMETER PIPE
SUPPORT(TYP.) BELOW
STEEL PLATE. SEE PIPE
SUPPORT DETAIL ON THIS
SHEET
EXISTING STEEL RAMP TO BE RE-INSTALLED
WITH A NEW STEEL ANGLE
S-104
D1 S-104
PERIMETER FLOOR EDGE DETAIL
SCALE: NOT TO SCALE
ENTRANCE FLOOR & RAMP DETAIL
SCALE: NOT TO SCALE
S-104
S-104
S-104
S-104
D2
NEW SUPPORT PIPE LAYOUT
SCALE: 1/4"=1'-0"
NEW STAINLESS STEEL PLATES LAYOUT
SCALE: 1/4"=1'-0"
SUPPORT WITH ONE
1/4" DIAM. HOLES FOR
CONCRETE ANCHORS
(18 EACH)
1/4" THICK STAINLESS STEEL PLATES
WELDED ON TOP AND BOTTOM OF
PIPE SUPPORT
PIPE SUPPORT-TOP VIEW
INSULATED FLOOR PANELS
CONCRETE FOUNDATION
LEGEND
N 8'-0"
7' -1 0"
4"
N
FLAT-HEAD STYLE SCREW,
COUNTERSUNK INTO TOP PLATE
TO MOUNT PIPE SUPPORT TO
CONCRETE FLOOR.
PIPE SUPPORT DETAIL(TYP.)
SCALE: NOT TO SCALE
MDP ATS
PPR
BC
3 3 3 3
86 76
4 4
4 4
4 4
D3
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
E L
E C
T R
IC
A
L D
E M
O L
IT
IO
N W
O R
K S
PL
A
N
SHEET ID
E-101
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T
O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
ELECTRICAL DEMOLITION NOTES
1 DISCONNECT EXISTING BATTERY CHARGER MODEL ETP36-483/3/160. ONCE
DISCONNECTED REMOVE JUNCTION BOX AND CONDUIT NEAR DEVICE AND
COIL CABLES UP TO JUNCTION BOX ABOVE. COORDINATE WITH COR TO
DESIGNATE AREA FOR TEMPORARILY RECONNECTING BATTERY CHARGER
USING COILED CABLES TO MAINTAIN DEVICE IN OPERATION DUE TO NEW
WORKS AT SHEET E102. ONCE THE NEW WORKS ARE DONE THE DEVICE SHALL
BE RECONNECTED AS INDICATED SHEET E102.
2 REMOVE AND DISPOSE OF 30A 3 POLES BREAKERS AT MDP CIRCUIT
#12, #14 AND #16. REMOVAL OF THIS DEVICE SHALL BE DONE WHEN
TEMPORARY POWER FOR BATTERY CHARGER IS NO LONGER NEEDED.
3 REMOVE AND DISPOSE OF WALL PACK LIGHTING FIXTURES. CIRCUITS SHALL
BE REMOVED BUT CONDUITS SHALL REMAIN.
4 REMOVE AND DISPOSE 1' X 4' LIGHTING FIXTURES, ALL OTHER FIXTURES IN
CIRCUIT SHALL REMAIN.
5 REMOVE AND DISPOSE EXIT SIGNS, CIRCUIT SHALL REMAIN.
6 REMOVE FIRE PULL STATION AND STROBELIGHT, COORDINATE THE REMOVAL
OF THESE ITEMS WITH COR TO RECEIVE SUPPORT FROM FORT BUCHANAN FIRE
ALARM SYSTEMS CONTRACTOR.
7 REMOVE AND DISPOSE POWER CABLES PROVIDING POWER TO BATTERY
CHARGER , ALL THE WAY FROM MDP. REMOVAL OF THIS CABLES IS TO BE
DONE WHEN THE TEMPORARY POWER FOR BATTERY CHARGER IS NO LONGER
NEEDED.
ELECTRICAL PANEL, NAME OR DESIGNATION ON CENTER
1' X 4' LED T8 LIGHT FIXTURE, LETTER INDICATES PATTERN.
LED WALL PACK WITH PHOTOCELL LIGHTING CONTROL
JUNCTION BOX, 6" X 6" X 6"
RECEPTACLE
EMERGENCY EXIT SIGN AND LIGHT FIXTURE WITH BATTERY
FIRE ALARM STROBE LIGHT
FIRE ALARM PULL STATION
RIGID GALVANIZED STEEL
ELECTRICAL METALLIC TUBING
OVER CURRENT PROTECTIVE DEVICE
BATTERY CHARGER - MODEL ETP36-483/3/160
MDP
A
RGS
EMT
OCPD
ELECTRICAL LEGEND
(THIS SHEET ONLY)ELECTRICAL REMOVAL ITEMS LIST: (QUANTITIES ARE APPROXIMATE, VERIFY IN FIELD)
ITEM QUANTITY UNIT DESCRIPTION REMARKS
D1 COIL UP BATTERY CHARGER POWER CIRCUIT UP TO JUNCTION BOX ABOVE. POWERED FROM BREAKERS 12, 14 AND 16 ON MDP PANEL.
D2 30 AMPS 3 POLES BREAKERS.
D3 10 EA HIGH INTENSITY LIGHTING FIXTURES. LOCATED OUTDOOR.
D4 6 EA 1' X 4' LIGHTING FIXTURES HIGH HANG. TO BE REMOVED AND DISPOSED
JOB1
1 EA
D5 D6 D7 D8
1 EA JUNCTION BOX WITH POWER CABLES FOR BATTERY CHARGER TO BE REMOVED AND DISPOSED
D9
4 EA EXIT SIGN AND LIGHT WITH BATTERY BACKUP TO BE REMOVED AND DISPOSED
1 EA FIRE ALARM STROBELIGHT TO BE REMOVED AND DISPOSED WITH PRIOR COORDINATION WITH COR.
1 EA FIRE ALARM PULL STATION TO BE REMOVED AND DISPOSED WITH PRIOR COORDINATION WITH COR.
TO MDP
D3 D3 D3
D3
D6
D3 D3 D3D3
D4 D4
D4 D4
D4 D4
D3
ELECTRICAL DEMO WORKS FLOOR PLAN
SCALE: 1/8"=1'-0"
S
PS
N
SPS
1 JOB TEMPORARY DISCONNECT EXISTING BATTERY CHARGER MODEL ETP36-483/3/160 DEVICE TO REMAIN. AND TO BE RECONNECTED TEMPORARILY ON ANOTHER LOCATION.
BC
TO BE REMOVED AND DISPOSED, WHEN BATTERY CHARGER IS TO BE CONNECTED AT FINAL LOCATION.
D7 D8
D2
D6
D6 D6 D1 D5 D9 D10
D10 100 LF REMOVE AND DISPOSE POWER CABLES FROM BATTERY CHARGER CIRUIT UP TO MDP REMOVAL SHALL BE DONE WHEN BATTERY CHARGER WILL BE LEFT FUNCTIONING AT FINAL LOCATION.
D11 1500 LF REMOVE AND DISPOSE POWER CABLES FROM EACH WALL PACK . TO BE REMOVED AND DISPOSED.
D11 D11 D11
D11
D11D11D11 D11
D11
D11
AutoCAD SHX Text
AutoCAD SHX Text
MDP
PPR
ATS
TO PPR
PPL
TO MDP
FC
USE JUNCTION
BOX 6X6X6
TO EXIT
BUILDING.
BC
2 2
27 27
31 45
4 26 4
1 1 7 15
MS
18 18 18
17 17 17
18 18 18
3 3 3 3 3
24 MS
29 33
4 4 4
11 24 MS
24 MS
8 9
10 22
MS
1E
1E
3 3 3
E7 E15 E40
DPW ENGINEERING
DIVISION
R E
PA
IR
T O
(S
SM
O ) F
O R
A D
D
IT
IO
N
A L
C E
R T
IF
IC
A T
IO
N
R E
Q U
IR
E
M E
N T
S
E L
E C
T R
IC
A
L N
E W
W O
R K
S
PL
A N
SHEET ID
E-102
D R A W N B Y : C
. K U G
LE
R
C H
EC
K
ED
B Y
R
EC
O M M
EN
D
ED
B Y : L
U
IS
E . T
O R R
ES
A
PP
R O V
ED
B Y : A
N
IB
A L N
EG
R O N
D
ES
IG
N
ED
B Y
R
EV
IS
IO
N S
N O
D A
TE
D
ES
C R
IP
TI
O N
A
PP
R O V A L
NEW ELECTRICAL ITEMS LIST: ( QUANTITIES ARE APPROXIMATE , CORROBORATE ON FIELD )
ITEM QUANTITY UNIT DESCRIPTION
E1 8 EA 1' X 4' LED T8 LIGHTING , WALL MOUNTED.
TO ILLUMINATE AREA BEHIND WALK-IN COOLER AND FREEZER, INTERIOR AREA. NEW CIRCUIT ON EXISTING
PANEL PPR.
E2 10 EA LED WALL PACK 120V, 80 WATTS , 12,000 LUMENS WITH PHOTOCELL.LIGHTING CONTROL TO ILLUMINATE PERIMETER OUTSIDE, ONE NEW CIRCUIT ON PANEL PPR.
E3 16 EA 1' X 4' LED T8 LIGHTING, CEILING MOUNTED. TO ILLUMINATE AREAS UNDER CANOPIES ON OUTDOORS, ONE NEW CIRCUIT ON PANEL PPR
E4 4 EA THREE WAY LIGHTING SWITCHES FOR LIGHTING CONTROL. FOR EXTERIOR AND INTERIOR LIGHTING CONTROL.
E5 1 EA 480V, 100 AMPS , NEMA 3R PANELBOARD WITH 60 AMPS MAIN BREAKER. ( AT LEAST 9 SPACES ) POWERED FROM DRY TYPE TRANSFORMER. NEW PANEL SHALL BE DESIGNATED AS PPL.
E6 1 EA 50 KVA, DRY TYPE , STEP UP TRANSFORMER 208V TO 480V TO BE POWERED FROM MDP USING APPROPIATE OCPD. WINDINGS SHALL BE COPPER.
E7 1 EA 150 AMPS , 3 POLES BREAKER FOR NEW DRY TYPE TRANSFORMER NEW TRANSFORMER OCPD PROTECTION TO BE INSTALLED AT PANEL MDP.
E8 2 EA 60 AMPS , 480 V , NEMA 4X SS DISCONNECT SWITCH. FOR NEW REFRIGERATED CONTAINER CIRCUIT.
E9 4 EA 6'' X 6'' X 6'' JUNCTION BOX 2 TO BE USED FOR ADAPTING PIN AND SLEEVE RECEPTACLE AND 2 TO BE USED FOR A/C POWER CIRCUIT.
E10 1 EA WATER TIGHT PIN AND SLEEVE RECEPTACLE , 30 AMPS , 4 PIN RECEPTACLE TO BE ACTIVATED / DE-ACTIVATED VIA DISCONNECT.
E11 4 EA TO BE USED AS SPLICE BOX FOR BATTERY CHARGER CIRCUIT AND FOR BUILDING CONDUIT EXIT, RECEPTACLE RUNS
E12 1 EA
E13 2 EA 30 AMPS 3 POLES BREAKERS, 480V FOR TWO NEMA 4X SS DISCONNECT SWITCHES POWER E14 5 EA 20 AMPS 1 POLE BREAKERS. FOR INTERIOR 1X4 / EXTERIOR 1X4 LIGHTING FIXTURES, AND GFCI RECEPTACLE.
E15 1 EA FOR ONE THE BATTERY CHARGER CIRCUIT
E16 130 LF 1 - 1 / 2 " EMT CONDUIT FOR NEW TRANSFORMER CONDUCTORS AND AIR CURTAINS
E17 800 LF 1 '' EMT CONDUIT FOR INDOOR CIRCUIT RUNS.
E18 270 LF 1 '' RGS CONDUIT FOR OUTDOOR CIRCUIT RUNS.
E19 680 LF AWG # 12 THHN / THWN-2 CONDUCTOR L1 AND N FOR ALARM CIRCUITS, ROLLUPDOOR AND EMERGENCY LIGHTING FIXTURES.
E20 240 LF AWG # 1 / 0 THHN / THWN-2 FOR NEW TRANSFORMER.
E21 80 LF AWG # 2 THHN / THWN-2 FOR NEW TRANSFORMER , GROUND.
E22 1500 LF
E23 6 EA
AWG # 10 THHN / THWN-2 FOR TWO NEW REFRIGERATED CIRCUIT DISCONNECTS SWITCHES , INCLUDING GROUND
E24 2 EA
MOTION SENSORS FOR LIGHTING CONTROLS , OUTDOOR. FOR EXTERIOR CIRCUITS AT NEW CANOPY AREA AND INTERIOR LIGHTING AREA
E25 2 EA
3/4" " CONDULETS RGS FOR NEW A/C CIRCUIT TRANSITIONS
E26 1 JOB TO BE CONNECTED AT PANEL MDP
E27 1 EA TO PROVIDE OCPD TO NEW PANEL FROM TRANSFORMER.
6'' X 6'' X 6'' JUNCTION BOX
35 AMPS 3 POLE BREAKERS.
FOR REFRIGERATOR AND FREEZER ALARM. INDICATES BY FLASHING AND SOUND WHEN NOIT OPERATING.NEW STROBE LIGHT AND HORN NEW PUSH BUTTON BOX, AIR CURTAIN AND COILING DOOR CIRCUIT WITH OCPD 3 POLE 20 AMP BREAKER
100 AMPS 3 POLES , BREAKER.
E28 29 LF TO MOUNT PROVIDE FIXED MOUNTING FOR EXTERIOR AND INTERIOR LIGHTING.GALVANIZED UNISTRUT CHANNEL
E29 1 JOB NEW DEVICES SHALL FUNCTION WITH EXISTING LOGIC.PROGRAM AND TEST NEW STROBELIGHT AND HORN WITH EXISTING ALARM SYSTEM
REMARKS
E30 4 EA FOR LUMINAIRE AVAILABILTY AND EXIT INDICATION DURING POWER OUTAGE.EMERGENCY EXIT SIGN AND LIGHT WITH BATTERY BACKUP
E31 1 EA FOR MISSING COVER.DUPLEX RECEPTACLE COVER
E32 2 EA FOR SUMP PUMP AREA AND WATER DISTILLER AREA.DUPLEX GFCI RECEPTACLE WITH OUTDOOR TYPE COVER
E33 200 LF FOR CIRCUIT ENCLOSED ON 6 X 6 X 6 JUNCTION BOX. BATTERY CHARGERAWG # 6 THHN-THWN-2
E34 100 LF AWG # 10 GROUND FOR CIRCUIT ENCLOSED ON 6 X 6 X 6 JUNCTION BOX. BATTERY CHARGER
E35 1 EA WATER HEATER EQUAL OR SIMILAR TO STIEBEL ELTRON CE PLUS 15KW FOR HOT WATER AT SANITATION SINK . WATER TEMPERATURE NO LESS THAN 110 DEGREES FAHRENHEIT
SINGLE POLE LIGHTING SWITCH FOR BATTERY CHARGER AREA LIGHT
E36 22 EA FOR OUTDOOR CANOPIES GROUNDING
E37 150 LF
GROUND BONDING JUMPERS
E38 600 LF AWG # 6 THHN-THWN-2
E39 200 LF
E40 1 EA FOR NEW WATER HEATER CIRCUIT CONNECTED AT MDP
AWG # 10 THHN-THWN-2
50 AMPS 3 POLE BREAKER
WATER HEATER CABLES L1 L2 L3
WATER HEATER GROUND
3/4 " RGS CONDUIT FOR EXTERIOR WALL PACKS
E41 2 EA FOR CONDUIT EXIT RUN , GFCI RECEPTACLE RUNS.6X6X6 JUNCTION BOXES
E42 200 LF NEW DEVICES WILL BE CONNECTED USING MANUFACTURER WIRE RECOMMENDATION SEE NOTE 24 SHEET E-103WIRE DISTANCE FOR PUSH BUTTON / AIR CURTAIN AND ROLL UP DOOR.
E43 1 EA FOR NEW ROLL UP DOOR.30 AMPS DISCONNECT SWITCH NEMA 3R
E44 50 LF FOR NEW ROLL UP DOOR RUN FROM MDP1 - 1/2" EMT CONDUIT
E45 1 EA FOR NEW AIR CURTAIN, SEE EXISTING PANEL SHCEDULE AND NOTE 24 SHEET E-103.20 AMPS 3 POLES BREAKER
MDP
A
X
T
EXISTING FREEZER/COOLER ALARM CONTROL PANEL
# ABOVE INDICATES CONTROL LOGIC ASSOCIATED
ELECTRICAL PANEL, NAME OR DESIGNATION ON CENTER
1' X 4' LED T8 LIGHT FIXTURE, LETTER INDICATES PATTERN. TWO
NEW CIRCUITS ON PANEL PPR.
LED WALL PACK WITH PHOTOCELL LIGHTING CONTROL
POWERED FROM EXISTING CIRCUIT ON PANEL MDP
LIGHTING SWITCH, LETTER INDICATES PATTERN TO
CONTROL
JUNCTION BOX, 6" X 6" X 6"
NEW PUSH BUTTONS AND ELECTRICAL CIRCUITS TO
CONTROL NEW ROLL UP(COILING) DOOR
MOTION SENSOR, LETTER INDICATES POWER TO
CONTROL
DRY TYPE TRANSFORMER, 50KVA
STEP UP 208V TO 480V
DISCONNECT SWITCH UNFUSED , CAPACITY ON DRAWING
RECEPTACLE, 30AMPS
SECURITY FOGLIGHT
STROBE AND HORN ALARM DEVICE, LETTER INDICATES
CONTROL PANEL LOGIC ASSOCIATED
EMERGENCY EXIT SIGN AND LIGHT FIXTURE WITH BATTERY
RESET PUSH BUTTON, LETTER INDICATES CONTROL
PANEL LOGIC ASSOCIATED
WATER HEATER
RIGID GALVANIZED STEEL
ELECTRICAL METALLIC TUBING
OVER CURRENT PROTECTIVE DEVICE
BATTERY CHARGER
CP
MS
A
RGS
EMT
OCPD
WH
PB
ELECTRICAL LEGEND
(THIS SHEET ONLY)
TO MDP
TWO CIRCUITS, NEW WORKS NOTE 11, WITHIN SPLICE BOX, CABLES WILL REMAIN COILED
AND PROTECTED WITH PLASTIC WIRE CONNECTORS WITH BREAKER TURNED OFF AT PANEL
MDP. RE-USE JUNCTION BOXES ABOVE CONCRETE WALL, IN ORDER TO EXTEND CABLE RUN
AND REACH OUTER AREA , HOLE CAN BE DRILLED ON METAL FRAME INSTEAD OF CONCRETE.
USE WATER TIGHT COUPLINGS AND FITTINGS WHEN THIS JOB IS PERFORMED.SPLICE CIRCUIT
EXTENSIONS TO ARRIVE AT NEW LOCATION
NEW STROBE LIGHTS AND HORN, NEW WORKS NOTE #27 SHALL BE CONNECTED TO EXISTING LOGIC PROGRAM ON
FREEZER ALARM CONTROL PANELS ,
THEY SHALL START MAKING LIGHT AND SOUND ALARMS WHEN THE CONDITIONS OF ACTIVATING THE EXISTING FREEZER
/ COOLER ALARMS ARE MET.
THE ALARMS SHALL TURN OFF WHEN EACH RESET BUTTON IS PRESSED. CONTRACTOR SHALL MAKE SURE THAT THE DEVICES OPERATE UNDER THE LOGIC PROGRAM PREVIOUSLY SET ON EACH CONTROL PANEL THE ONLY ADDITION IS TO ADD AN EXTRA OUTPUT DEVICE TO THE…