APPENDIX_E_-_3_OF_4_Drawings.pdf

PDF 293 KB Posted

Attached to
KC46A FTU Fuselage Trainer Phase 2 Altus AFB Federal contract opportunity
Solicitation number
W912BV-18-R-0002
Issued by
Department of the Army Corps of Engineers Engineering District Tulsa

About this file

Appendix E - Drawings - File 3 of 4 (Amendment 0001)

View the file

Other files for this federal contract opportunity

Other files attached to KC46A FTU Fuselage Trainer Phase 2 Altus AFB, newest first.
File Type Posted
Amendment_0005_SF30(Final).pdf PDF
FUT_PH_2_site_visit_12-FEB-2018.pdf PDF
Amendment_0004_SF30(Final).pdf PDF
W912BV18R0002_Amendment_0003.pdf PDF
W912BV18R0002_Amendment_0002.pdf PDF
APPENDIX_E_-_1_OF_4_Drawings.pdf PDF
APPENDIX_E_-_2_OF_4_Drawings.pdf PDF
APPENDIX_E_-_4_OF_4_Drawings.pdf PDF
APPENDIX_C_Structural_Interior_Design_(SID).pdf PDF
SF30_W912BV18R0002_AMD_0001.pdf PDF
AM01_TABLE_OF_CONTENTS.pdf PDF
APPENDIX_D_Geotechnical_Report_(2).pdf PDF
W912BV18R0002_Solicitation_Final.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PVC PIPE PVC PIPE

RUN ANODE LEAD WIRES (RED),

REFERENCE CELL LEAD WIRE

(GREEN), AND TEST LEAD WIRES

(BLACK) INTO THE TEST STATION

UNSPLICED

PLAN

PVC PIPE

VALVE

GRADE

ELEVATION

PVC PIPE

EXOTHERMIC WELD. SEE

DETAIL A4 THIS SHEET

6" MIN O.D. FLUSH MOUNTED CP TEST

STATION - METAL LID

MARKED "CP TEST".

6" THICK BY 2'-0"

SQUARE

CONCRETE PAD

GRADE

17 LB MAGNESIUM

ANODE (TYP OF 2)

UNDERGROUND

FERROUS FITTING

OR JOINT

#14 GREEN HMWPE

REFERENCE

CELL LEAD

#10 BLACK HMWPE AWG

INSULATED STRUCTURE WIRES

METAL WELDING

POWDER

STARTING POWDER

WIRE

SLEEVE

METAL DISC

GRAPHITE MOLD

METAL SURFACE

GRAPHITE COVER

HOLD

HANDLE

METAL SURFACE

EXOTHERMIC WELD

(TYP)

WELD COATING

COPPER SLEEVE

#10 AWG STRANDED

COPPER WIRE WITH

HMWPE INSULATION

STEP 1. FILE STRUCTURE CONNECTION AREA (3"x3")

TO BARE SHINY METAL AND CLEAN.

STEP 2. STRIP INSULATION FROM WIRE. ATTACH SLEEVE.

STEP 3. HOLD MOLD FIRMLY WITH OPENING AWAY FROM OPERATOR AND

IGNITE WITH FLINT GUN.

STEP 4. REMOVE SLAG FROM CONNECTION AND PEEN WELD FOR

SOUNDNESS.

STEP 5. COVER CONNECTION AND EXPOSED STRUCTURE SURFACE WITH

A BITUMINOUS COATING COMPOUND.

1. PROCEDURE SHOWN ABOVE IS TO BE USED AS A GENERAL GUIDE ONLY. CONSULT MANUFACTURER'S

LITERATURE FOR SPECIFIC INSTALLATION INSTRUCTIONS.

COPPER/COPPER

SULFATE REFERENCE

CELL (PLACED IN

SIMILAR SOIL

ENVIRONMENT AND

DEPTH OF PIPING)

SHUNT

(0.1Ω FACTOR)

METAL

SURFACE

METAL WELDING POWDER

WIRE

GRAPHITE MOLD

METAL DISC

STARTING POWDER

HOLD

HANDLE

GRAPHITE COVER

SLEEVE

METAL SURFACE

WELD CAP

MASTIC

CABLE

COPPER

SLEEVE

EXOTHERMIC

WELD (TYP.)

#12 RED HMWPE AWG

ANODE LEAD WIRES

17 LB MAGNESIUM ANODE

(TYP OF 2)

17 LB MAGNESIUM

ANODE (TYP OF 2)

SCALE: NTS

45° & 90° ELBOWS AND TEES

A1

SCALE: NTS

TEST STATION TERMINAL BOARD

D1

SCALE: NTS

FIRE HYDRANT WITH VALVE

D7

SCALE: NTS

TEST STATION INSTALLATION

D5

SCALE: NTS

EXOTHERMIC WELD

A4

17 LB MAGNESIUM ANODE (TYP OF 2)

SINGLE FITTING

GRADE

TEST STATION

PVC PIPE

DETAIL PLAN VIEW

DETAIL ELEVATION VIEW

17 LB ANODE (TYP OF 2)

SINGLE FITTING FOR VALVES

NOTE:

TEST STATION

COPPER/COPPER SULFATE

REFERENCE CELL (PLACED IN

SIMILAR SOIL ENVIRONMENT

AND DEPTH AS PIPING)

COPPER/COPPER SULFATE

REFERENCE CELL (PLACED IN

SIMILAR SOIL ENVIRONMENT

AND DEPTH WITHIN 12-INCHES

OF PIPING)

COTT

.100 ohm

RED - 0.1 ohm, 2 AMP CAPACITY

COPPER/COPPER SULFATE

REFERENCE CELL

EXOTHERMIC WELD (TYP)

(SEE DETAIL A4 THIS SHEET)

EXOTHERMIC WELD (TYP)

(SEE DETAIL A4 THIS SHEET)

COPPER/COPPER SULFATE

REFERENCE CELL (PLACED IN

SIMILAR SOIL ENVIRONMENT AND

DEPTH WITHIN 12-INCHES OF PIPING)

7/31/2017 1:28 PM

Z:\Clients\ANF\USCOE\SwT\93058_AltusFuT2\Design\Civil\Sheets\93058-CP501.dwg

K

W

A R

T A

C

P

D

W G

S

L

U E

H R

S

S

W

A G

N E

R

C A

T H

O D

I C

P

R O

T E

C T

I O

N

D

E T

A I L S

2-CP501

B U

R N

S

M c D

O N

N E

L L

W

A R

D

P

A R

K W

A Y

K A

N S

I T

Y

O

US ARMY CORPS

OF ENGINEERS ®

D

2 3

C

A

B

D R

A W

I N

G

C

O D

E

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

I S

S U

E

D

A T

E

C H

E C

K E

D

B

Y

S C

A L

E

SHEET

REFERENCE

NUMBER:

C O

P Y

R I G

H T

B

U R

N

D

D

O N

N E

L L

E

N G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

6 7 8 9

D A

T E

E

F

FILE:

DATE:

P R

O J E

E

G

I N

E E

R A

R C

H I T

E C

T

TULSA DISTRICT

D

A T

E A

P P

R

D E

S C

R I P

T I O

N S

Y M

B O

L

R E

V I S

I O

N S

D E

P A

R T

M E

F

T

H E

R M

Y

U S

A

R M

Y

C

O R

P

F

E

N G

I N

E E

R S

TU

LS

A D

IS

TR

IC

T

O K

L A

H O

M A

AL

TU

S

AI

R

FO

RC

E

BA

SE

, O

KL

AH

OM

A

PR

OJ

EC

T

NO

. A

GG

N1

F Y-

KC

-4 6A

F

TU

F

US

EL

AG

E

TR

AI

NE

R

PH

AS

E

R

E A

D Y

A

D V

E R

T I S

E

File details come from the government source that posted it.