W25PHS83461559
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
1. Answ ers to Requests for Information (RFI's)
2. Sign-in Sheet from Site Visit (15 February 2019)
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 04-Mar-2019
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912BU19B0002
X 9B. DATED (SEE ITEM 11)
05-Feb-2019
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
05-Mar-2019
CODE
US ARMY ENGINEER DISTRICT, PHILADELPHIA
POC: ROBERT HUTCHEON
WANAMAKER BUILDING
100 PENN SQUARE EAST
PHILADELPHIA PA 19107-3390
W912BU 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912BU19B0002
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
(End of Summary of Changes)
Q# Question Response
1 Will you send out the sign‐in sheet? The sign‐in sheet will be attached to this Amendment.
2 What are the dimensions of this place?
Floor dimensions are shown on plan sheets, including S‐
101. The ceilings are 24 ft, except 30 ft in the clearstory.
3 Can all phases be done together?
See Spec Section 01 10 00 Para 1.5. Phases cannot be completed together.
4 Does the work extend beyond the doors into the next bay?
The entire work area is shown on the plan sheets. No work will occur outside of the spaces shown in the plans.
5 Has there been lead testing?
Yes, numerous paint samples were anlayzed for lead.
See results in Spec Section 02 83 13.00 20.
6 Does the floor tile contain asbestos?
Gray and yellow floor tiles were analyzed for asbestos, none detected. A mastic sample was also negative for asbestos. See results in Spec Section 02 83 13.00 20.
7 Will the offices be occupied, vacated?
The offices will be vacated, but Government personnel may occasionally need to access the offices through the entrances outside of the current phase work area.
8 Is the space going to be empty? Who is going to empty what?
See Spec Section 01 10 00 Para 1.5. The government will empty the spaces with proper advance notice from the contractor.
Are the fiber‐resin panels considered windows? Do we do anything with them?
Yes, the clear panels in the clearstory are considered windows and shall be cleaned per Spec Section 01 10 00
Para 3.1.
10 Do 4 cores need to be taken from the slab? Where? Core locations are shown on plan sheet S‐101.
11 Where does the raised pad go?
The raised concrete slab location is shown on plan sheet
S‐101 and Detail 6 on S‐501.
12 Do you want existing epoxy floor coating removed?
All surfaces to be painted shall be prepared in accordance with Spec Section 09 90 00.
13 Which cracks in the columns need repair?
Refer to sheet S‐101 for crack location adjacent to column bases. Sheets S‐503 and S‐504 provide reference photos.
14 What are the repairs above the rails?
Repairs include patching spalled areas adjacent to rails and where portions of rail are missing. Refer to details 1 through 4 on sheet S‐501 and Photo 3 on S‐504.
15 Are we allowed to paint conduit and access panels?
See Spec Section 09 90 00 Para 1.9. Conduits are to be painted, but powerpanels are excluded from painting.
16 Do we have to paint the powder coated garage door?
See Spec Section 09 90 00 Para 1.9. Roll‐up doors are excluded from painting.
17 Is there any painting behind the cages?
See Spec Section 09 90 00 Para 1.9. Yes, the walls behind the tool cages and office mezzanine are to be painted.
18 Do we also paint the wood inside the cages?
See Spec Section 09 90 00 Para 1.9 for list of items included and excluded from painting.
19 Do we paint the walls in the mezzanine, behind the mezzanine?
See Spec Section 09 90 00 Para 1.9. All masonry walls are to be painted, but office mezzanine walls (exterior and interior) are excluded from painting.
20 How do we get up there above the drop ceiling in the mezzanine?
Means and methods of access are to be determined by the contractor.
21 Can we look above the drop ceiling to see how to get above it?
Access does not exist through the drop ceiling in the offices.
22 Do the murals on the walls have to be saved? No, the murals are to be painted over.
Will USACE take better pictures of the space and work needed, particularly walls and ceilings?
A site visit was held on 15 February to view the space.
Additional photos will not be released.
Will there be additional drawings released to indicate where exactly the lead based paint and zinc is located? It is referenced in the specification section 028313, section 1.3.1. It's not a line item in pricing. This cost could vary greatly depending on what is assumed at the time of submitting the bid to cover any and all items, versus submitting change orders.
All paint samples analyzed postive for lead, no areas could be positively discerned as not containing lead based paint. See results in Spec Section 02 83 13.00 20.
Regarding the note to patch floor above existing metal rails, are we patching the cracks/gaps or removing and filling it in?
The rails will not be removed. Repairs include patching spalled areas adjacent to rails and where portions of rail are missing. Refer to details 1 through 4 on sheet S‐501 and Photo 3 on S‐504.
How does the lowest bidder get evaluated in the pre‐award survey to be determined as a responsible bidder? What criteria would disqualify the lowest bidder?
FAR Part 14.4 addresses bidder responsiveness and responsibility.
Is there a solid surface above the 2nd floor offices in the large warehouse area? If not, what is above the ceiling tiles in those offices?
The roof of the office mezzanine is corrugated steel decking. The PSF capacity is unknown.
Who will be responsible for moving Navy material and equipment in the work areas, including the caging areas?
See Spec Section 01 10 00 Para 1.5. The government will empty the spaces with proper advance notice from the contractor.
Are we allowed to paint over electrical conduit on the walls/ceilings/support beams?
See Spec Section 09 90 00 Para 1.9. Conduits are to be painted.
Are we responsible paint the walls behind the offices? If so is there access to those areas?
See Spec Section 09 90 00 Para 1.9. Yes, the walls behind the tool cages and office mezzanine are to be painted.
Means and methods of access are to be determined by the contractor.
Can we please get some pictures of the ceiling/walls/support trusses/I
Beams?
A site visit was held on 15 February to view the space.
Additional photos will not be released.
Will our workers have access to use restrooms, or do we need to supply our own porta johns?
See Spec Section 01 10 00 Para 1.18.3.
Can the government take addition photos's of the existing room showing the ceiling and to show the existing structure , the height of ceiling , the condition of the walls. The contract documents and plans do not show the amount of structural steel and the complexity of the project.
A site visit was held on 15 February to view the space.
Additional photos will not be released.
Does the existing red fire sprinkler line and existing conduits require painting?
See Spec Section 09 90 00 Para 1.9. Sprinkler piping is excluded from painting.
Bid item 4. Window cleaning estimated quantity is 1 with a unit price of lump sum, the plans do not show how many windows, how big are the windows, how high are the windows off the finish floor? Spec section
01 10 00 page 20 para 3.1 Window Cleaning states " Prior to any painting , remove cobwebs and clean and wash the interior of the existing clearstory windows ". Please clarify the square foot of the existing windows that required pricing under the lump sum ?
The four windows in the clearstory measure approximately 48 feet wide by 6 feet high, and are between 24 feet and 30 feet from floor level. For bidding purposes, assume 1200 square feet.
Can you let us know when the lead abatement amendment will be released confirming the lead paint scope of work?
The lead encapsulant requirement is included in
Amendment 1.
37 Are roof trusses to be painted in Phase 3?
Yes, the blue wooden roof trusses are located in the
Phase 3 area.
38 Can we obtain a copy of the sign‐in sheet from the site visit? The sign‐in sheet will be attached to this Amendment.
Drawing S‐101 Calls to patch floor above existing metal rails. What product is to be used for this patching? Are the Metal rails to be removed?
The rails will not be removed. Repairs include patching spalled areas adjacent to rails and where portions of rail are missing. Refer to details 1 through 4 on sheet S‐501 and Photo 3 on S‐504.
Drawing S‐101 says to paint floor. What floor system is to be used in these areas?
See Spec Section 09 90 00 Para 1.9.1.1.c. Paint for flooring shall be as specified in Section 09 67 23
STANDARD RESINOUS FLOORING.
Drawing S‐101 says to Pour new concrete to raise slab to level floor. Are the dimensions of this area to be leveled known?
See plan Sheet S‐101. Dimension of area to be raised with new concrete slab to meet adjacent floor is approximately 9'‐0" x 21'‐7". Area of existing floor to be leveled with self‐leveling cementitous underlayment material is approximately 45'‐9" x 21'‐7".
Section 09 67 23 ‐Standard Resinous Flooring references epoxy binder, polyurethane surface sealer, finished epoxy floor, and heavy duty epoxy flooring systems yet the drawings only indicate an epoxy bonding agent.
Please clarify the following:
a. Is there a resinous system to be installed on the finish floor?
b. If so, please provide detailed specifications to ioutline type and system requirement (number of coats, mils, finish, etc.)
c. And, provide updated drawings to show areas receiving such a system.
See Spec Section 09 90 00 Para 1.9.1.1.c. Paint for flooring shall be as specified in Section 09 67 23
STANDARD RESINOUS FLOORING. See Plan Sheet S‐101.
Entire area of floor, except as noted, shall be coated with resinous flooring system. The epoxy bonding agent referenced on the plans refers to the bonding agent used with concrete repairs as specified in Spec Section 03 01
30.
Project documents call for patching above the existing embedded metal rails. From previous experience, such repairs will crack and spall with any level of material/equipment movement over the surface. We would highly recommend removing the rails completely to avoid such damage.
Will the Government approve of this long‐term solution in lieu of the existing requirements?
The rails will not be removed. Repairs include patching spalled areas adjacent to rails and where portions of rail are missing. Refer to details 1 through 4 on sheet S‐501 and Photo 3 on S‐504.
Contract documents, plans, do not truly represent existing condition in reference to column line C and egress door located on the South side.
Differemce is shown between page S‐101 and S‐102. Will this decrepancy affect the dimension of the “Area of Damaged Concrete” shown on page S‐101.
The correct door location is shown on sheet S‐102. This will not affect the dimension of the area of damaged concrete shown on sheet S‐101.
Please acknowledge the requirement of key personnel to include
Project Engineer, Superintendent, QC Manager, Safety Technician and
Office Engineer as listed on page 5 Section 00 50 05 of the
Specifications.
Pre Award Survey is to be completed by the apparent low bid only or, if the low bid is found to be non‐responsive or not responsible, then to the next lowest bid only.
Will the project due date be extended to allow for proper review and adjustment to RFI answers?
Extension is not anticipated. Plan for bid opening on 12
March 2019 @ 1300 E
W912BU19B0002 Building 756 Painting & Concrete Repairs, Site Visit 0900 15 Feb 19 Attendees: Clearance Security
Name Citizenship Company Phone Level Approval Julio Oliva US J Oliva Enterprises, LLC 908-872-6342 None Frank McQuaid US J Oliva Enterprises, LLC 215-436-5568 None
Ektor Prifti US Alpha Contractors Group Inc 630-544-8371 None Bill Vasil Prifti US Alpha Contractors Group Inc 630-544-8371 None
Jose L. Masclans US LGC Global 215-390-7720 TWIC card
Steven Botas US Taino Construction Group LLC 484-648-0343 None Nick Gjevukaj US Taino Construction Group LLC 484-648-0343 None Daniel Alston US Taino Construction Group LLC 484-648-0343 None
Alexander James US All American Mid-West, Inc. 804-644-0777 None Robin Cobb James US All American Mid-West, Inc. 804-644-0777 None
Mark Mariani US Schnoll 215-356-3885 None Joe Huebner US JF Huebner and Sons 215-416-1100 None
Paul Conway US Nadiad, Inc 732-692-7723 Green badge
Thomas Barry US Ranco Construction, Inc. 609-801-1808 DBIDS Michael Byrne US Quade Corp DBA Alpine Painti 215-348-4410 None
Tony Chase US Magnum Inc. 267-965-1910 None Mike Tilley US Schnoll Painting 267-965-1910 None Herbert J. Tiedeken III US Stenton Corporation 267-965-1910 None
Jose Carrera US EASE Painting and Constructio 443-563-1659 None Doris Zografos US EASE Painting and Constructio 443-563-1659 None
Gordon Scott Ramsay US Kunj Construction Corp. 201-889-7298 None Vijay Isip US Kunj Construction Corp. 201-889-7298 None
Ryan Dalbec US Best Choice Construction 763-439-0411 Level 5
David Hamilton US DCM Architecture & Engineeri 856-986-5598 HSPD-12 badge
Dilipkumar Devanahalli US Axiom Construction Managem 302-501-0667 USN access Chandru Gubbi US Axiom Construction Managem 302-501-0667 USN access
Daniel DeSantis US Reilly Construction 856-371-5097 GSA/FBI
John Malonoski US CJW Contractors Inc. (301) 395 6049 Yes Dane Shiplee US Union County Construction Gr (609) 458 9300 No Michael Shiplee US Union County Construction Gr (609) 458 9300 No
Ruben D. Romero US Rome Management 908.578.3896 Site Access Alan S. Toka US Rome Management 609.500.0426 Site Access
Victor Milbourne US Military Construction LLC 610-453-8662 None Michael Martin US Military Construction LLC 610-453-8662 None
Hispanic Ventures US Hispanic Ventures 215-988-0555 None
Dominic Meli US All Phase 609.558.5608 HSPD-12
James Conlin US L.J. Paolella Construction, Inc. 484-478-3525 None Matthew Kirlin US Tanglewood Painting, Corp. 610-613-7650 None
Shane Vazquez US Paradigm Services, Inc. 973-989-5888 None Paul Kandel US Paradigm Services, Inc. 973-989-5888 None Joe Cramer US Paradigm Services, Inc. 973-989-5888 None
Daniel Pittman Jr. US Ocean Construction 856-701-8937 Mike Miller US Hispanic Ventures 215-988-0555
Vaughn Butler US Skylar Painting LLC 877-447-2465 John Hasson US Skylar Painting LLC 877-447-2465 Mike Schenning US Paint Tech Inc. 877-447-2465
| Bldg 756 RFIs during Bid(final).pdf |
| Sheet1 |
| Site Visit Attendees W912BU19B0002 Building 756 Painting & Concrete Repairs.pdf |
| Sheet1 |
File details come from the government source that posted it.