This is an interior finish plan drawing (Sheet I-101-A) for the first floor of Area A (Lab & Admin) of the new USDA Dairy Forage Research Center in Prairie du Sac, WI. The drawing shows a detailed room finish schedule specifying floor, base, wall, and ceiling finishes for approximately 45 rooms including laboratories, offices, corridors, mechanical spaces, and support areas.
The plan indicates various finish materials including porcelain tile (PT), carpet (CPT), sealed concrete (PC), sheet flooring (HS), and epoxy flooring (EG) for floors; rubber base (RB), integral base (INT), and tile base for wall bases; painted walls (PNTL) with some areas receiving wall tile; and exposed structure (EXP), acoustic ceiling tile (ACT), and gypsum wall board (GWB) ceilings. Key design notes specify requirements for heat-welded sheet flooring seams, flooring transitions at doors, and paint specifications for visible duct surfaces. The drawing is dated November 8, 2024, under contract number W9128F21C0023 and was produced by HDR for the US Army Corps of Engineers Omaha District.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE:
REFER TO INTERIOR FINISH LEGEND SHEET
I-001 FOR FINISH CODES AND DESCRIPTION OF MATERIALS.
ROOM
NAME
FLOOR
BASE
WALL
CEILING
ROOM NUMBER
FLOOR FINISH
BASE FINISH
FIELD FLOOR FINISH - REFER TO
ROOM FINISH TAG
WALL FINISH
XX-XX
WALL ACCENT
CEILING FINISH
BOILER
ROOM
A43
CFS-HD
RB2
PNTLE-1
EXP
SEMINAR
ROOM
A02
CPT1
RB1
PNTL-1
EXP
TOILET
FEMALE
A04
PT-1
PT-1a
PNTLE-1
GWB
OVERNIGHT
NURSING
MOTHER
A05
HS2
RB2
PNTL-1
ACT-1
TOILET
MALE
A03
PT1
PT-1a
PNTLE-1
GWB
STOR.
TABLE /
CHAIR
A17
CFS-HD
RB2
PNTLE-1
ACT-1
DISPLAY
AREA
A01
PC-1
RB1
PNTL-1
EXP
WASHER/
DRYER
A36
HS1
INT
PNTLE-1
ACT-2
BREAK
A20
PC-1
RB1
PNTL-1
EXP
SHOWER
MALE
A21
PT-1
PT-2A
PNTLE-1
GWB
MUD
ROOM
A24
EG1
PNTLE-1
GWB
OFFICE
A07
HS2
RB1
PNTL-1
ACT-1
GLASSWARE
WASH
A26
HS1
INT
PNTLE-1
ACT-2
CYLINDER
A29
HS1
INT
PNTLE-3
ACT-2
INCUB.
ROOM
A31
HS1
INT
PNTLE-1
ACT-2
FERMENTATION
ROOM
A32
HS1
INT
PNTLE-1
ACT-2
LABORATORY
LARGE
A34
HS1
INT
PNTLE-1
ACT-2
LABORATORY
LARGE
A33
HS1
INT
PNTLE-1
ACT-2
SAMPLE
STORAGE
ROOM
A28
HS1
INT
PNTLE-1
ACT-2
CHEM
A27
HS1
INT
PNTLE-1
ACT-2
TELECOM
A16
SDRT-1
RB-2
PNTLE-1
EXP
GARBAGE
A25
HS1
INT
PNTLE-1
ACT-2
CORRIDOR
A39
PC-1
RB1
PNTL-1
EXP
CORRIDOR
A40
PC-1
RB-2
PNTLE-1
EXP
CORRIDOR
A38
PC-1/EG1
TT1
PNTLE-1
GWB
OFFICE
A08
HS2
RB1
PNTL-1
ACT-1
OFFICE
A09
HS2
RB1
PTNL-1
ACT-1
OFFICE
A10
HS2
RB1
PNTL-1
ACT-1
OFFICE
A11
HS2
RB1
PNTL-1
ACT-1
OFFICE
A12
HS2
RB1
PNTL-1
ACT-1
STOR.
ELEC.
A18
CFS-HD
RB2
PNTLE-1
ACT-1
ELEC
A19
CFS-HD
RB2
PNTLE-1
EXP
STOR.
A35
HS1
INT
PNTLE-1
ACT-2
SHOWER
FEMALE
A22
PT-1
PT-2A
PNTLE-1
GWB
JC
A23
CFS-HD
RB2
PNTLE-1
ACT-1
ELEC
A41
CFS-HD
RB2
PNTLE-1
EXP
ELEC
A42
CFS-HD
RB2
PNTLE-1
EXP
VESTIBULE
A01B
EG1
GWB
HS2
PC-1
COMPUTER
ROOM
A14
SDRT1
RB2
PNTLE-1
ACT-1
BCS
A15
CS2
RB2
PNTL-1
ACT-1
PRINT/COPY
A13
CF1
RB1
PNTL-1
EXP
WD1
WD1
W D
I1
CHILLER
ROOM
A44
CFS-HD
RB2
PNTLE-1
EXP
PC-1
HS2PC-1
EG1
UNIFORM
A45
CFS-HD
RB2
PNTL-1
ACT-1
OPEN
OFFICE
A06
HS2
RB1
PNTL-1
EXP
6'
0"
CG1
CG1
CG1
I1
WALK-IN
FREEZER
A30
I2
WD1 WD1
MECHANICAL
A37
CFS
RB2
PNTL-2
EXP
I3
RS-3
RS-3
RS-3
RS-2
RS-2 RS-1A RS-1
RS-3
CORRIDOR
A46
PC-1
RB-2
PNTLE-1
EXP
RS-1 RS-1 RS-1 RS-1 RS-1 RS-1 RS-1
RS-3RS-3
RS-3 RS-3 RS-3
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N E
W D
A
IR
Y F
O R
A G
E R
E S
E A
R C
H C
E N
T E
R
A u to d e s k D o c s
/1 U
S D
A D
F R
C /4
-A
-A R
E A
A -C e n tr a l.
rv t
/1
/2
:4
:5
P
M
I-101-A
IN
T
E R
IO
R
F
IN
IS
H
P L A
N
F
IR
S T
F L O
O R
A
R E
A A
L A
B
A D
M
IN
P R
A
IR
IE
D
U S
A C
W
I O
M A
H A
D
IS
T R
IC
T
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
T D
H Y
IW
M
T C
G
G K
T G
H
Y
/0
/2
W F
C
W F
C
NORTH
KEY PLAN
A
SHEET KEYNOTES
INTERIOR FINISH PLAN
LEGEND
3/32" = 1'-0" B1
FIRST FLOOR PLAN - AREA A - FINISH PLAN
I1 - ALL WALLS IN ROOM TO HAVE WALL TILE (PT-3) AT 5'-0" AFF.
REFER TO I-001-A.
I2 - REFER TO A-200 SERIES & ELEVATIONS FOR WALL FINISHES.
I3 - PAINT PARTITIONS PRIOR TO INSTALLATION OF WALK IN
FREEZER.
9. ALL SHEET FLOORING TO HAVE HEAT WELDED SEAMS AND
SELF-COVING BASE 6" A.F.F. UNLESS NOTED OTHERWISE.
8. WALL BASE DOES NOT EXTEND OVER STOREFONT OR OTHER
SPECIALTY WALL FINISH UNLESS SHOWN OTHERWISE.
7. ALL FLOORING TYPE TRANSITIONS AT DOORS SHALL OCCUR ON
THE CENTERLINE OF THE DOOR LEAF. TRANSITION TO BE
SMOOTH AND EVEN. MAXIMUM VERTICAL CHANGE IN ELEVATION
SHALL BE 1/4 IN. REFER TO SPECIFICATIONS FOR REQUIRED...
5. PAINT INTERIOR SURFACES OF DUCTS LOW VOC BLACK WHERE
SURFACES ARE VISIBLE THROUGH GRILLES AND DIFFUSERS.
4. UNLESS OTHERWISE INDICATED, DO NOT PAINT
FACTORY-FINISHED OR INSTALLER-FINISHED ITEMS.
3. WHERE ITEMS OR SURFACES ARE NOT SPECIFICALLY
MENTIONED, PAINT THE SAME AS SIMILAR ADJACENT MATERIALS
OR AREA. IF COLOR OF FINISH IS NOT DESIGNATED, ARCHITECT
WILL SELECT FROM STANDARD COLORS OR FINISHES...
2. DESIGN IS NOT INTENDED TO LIMIT THE SELECTION FOR EQUAL
COLORS FROM OTHER MANUFACTURERS. ANY COLOR
SUBSTITUTE MUST BE APPROVED BY ARCHITECT.
1. IF FINISH CODE IS NOT SPECIFIED (--), NO FIELD FINISH IS
APPLIED. REFER TO CORRESPONDING SPECIFICATION SECTION.
IF MANUFACTURER FINISH IS SPECIFIED (MFR), REFER TO
CORRESPONDING SPECIFICATION SECTION.
GENERAL NOTES
R T
A
/0
/2
HYANG
Line
HYANG
Line
HYANG
Text Box
PT-2A
HYANG
Text Box
HS2
HYANG
Line
HYANG
Line
HYANG
Text Box
HS2
HYANG
Line
HYANG
Text Box
PNTLE-1
HYANG
Line
HYANG
Text Box
PNTLE-1
File details come from the government source that posted it. Updated .