EAFB B-21 SIM Amendment AM-0009 Dwgs Vol2.pdf

PDF 281 KB Posted

Attached to
ADAL Flight Simulator Facility, Ellsworth AFB, SD Federal contract opportunity
Solicitation number
W9128F21R0080
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

This solicitation package describes a federal contract opportunity to design and construct an addition to an existing flight simulator facility at Ellsworth Air Force Base in South Dakota. The solicitation will close on October 15, 2021 and is open to both large and small businesses. Interested contractors must register in the System for Award Management and ensure the NAICS code 236220 for commercial and institutional building construction is included in their profile. The estimated value of the construction project is between $20-40 million. Due to site access limitations, the Army Corps of Engineers is providing virtual site access through photos, drawings and a teleconference to interested parties. Questions regarding the solicitation must be submitted through the Bidder Inquiry system in ProjNet. The solicitation documents can be downloaded from the Contract Opportunities section of SAM.gov using the provided solicitation number. The contract will be awarded by the Omaha District of the Army Corps of Engineers.

View the file

Other files for this federal contract opportunity

Other files attached to ADAL Flight Simulator Facility, Ellsworth AFB, SD, newest first.
File Type Posted
Am-0013_W9128F21R0080.pdf PDF
Am-0012_W9128F21R0080.pdf PDF
Am-0011_W9128F21R0080.pdf PDF
Am_0010.pdf PDF
EAFB B-21 SIM Amendment AM-0009 Dwgs Vol1.pdf PDF
Am_0009.pdf PDF
Am_0008.pdf PDF
AM-0008 Dwgs Vol2.pdf PDF
AM-0008 Dwgs Vol1.pdf PDF
Am-0007_W9128F21R0080.pdf PDF
Am-0006_W9128F21R0080.pdf PDF
Am-0005_W9128F21R0080.pdf PDF
Am-0004_W9128F21R0080.pdf PDF
100-Design_SPECS_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
100-Design_Vol1_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
100-Design_Vol2_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
Am-0003_W9128F21R0080.pdf PDF
Am-0002_W9128F21R0080.pdf PDF
Am-0001_W9128F21R0080.pdf PDF
100-BackCheck_DWGS_Vol2_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
100-BackCheck_DWGS_Vol1_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
Vol-1-Technical_SPECS_W9128F21R0080_B21-ADAL-Flight-Sim(EL95).pdf PDF
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12"

4"

BEAM CLAMP

CABLE TRAY ASSEMBLY

MOUNTING ASSEMBLY IN SECTION

NUTS & WASHERS

CABLE TRAY

SUPPORTS

1/2" THREADED

HANGER ROD

PIPE CLAMP

LISTED COPPER

GROUNDING STRAP AT

EVERY TRAY JUNCTION

BOND #6 Cu FROM CABLE

TRAY TO CONDUIT (TYP)

NOTE:

CONDUIT ROUTED TO TERMINATION BOXES IN ROOMS (TYP)

1 1/4" EMT CONDUIT WITH CABLING

AS SHOWN IN RISER DIAGRAM.

ROUTE CONDUIT TO CABLE TRAY

ABOVE ACCESSIBLE CEILING,

PROVIDE INSULATED BUSHING ON

END OF CONDUIT.

4 11/16" SQUARE OUTLET BOX AND

COMMON FACE PLATE WITH FIBER

ADAPTERS AS SHOWN ON PLAN

DRAWINGS. PROVIDE 12" OF CABLE

SLACK AT CABLE TRAY

DUPLEX LC

ADAPTERS

G

LABEL

BL

OUTLET CONFIGURATION 1

G BL

LABEL

LABEL

OUTLET CONFIGURATION 2

LABEL

G

LABEL

BL

OUTLET CONFIGURATION 3

LABEL

O

LABEL

BL

OUTLET CONFIGURATION 4

LABEL

R

LABEL

R

OUTLET CONFIGURATION 5

LABEL

LABEL

OUTLET CONFIGURATION 6

G

MTG. STUDS

FOR WALL

MTD.

TELEPHONE

O R

O BL

LABEL

OUTLET CONFIGURATION 7

LABEL

O R

O R

O

LABEL

R

OUTLET CONFIGURATION 8

LABEL

BL BL

G GREEN

CONNECTOR

R

RED

CONNECTOR

O

ORANGE

CONNECTOR

BL

BLANK

(SPARE)

O

LABEL

O

OUTLET CONFIGURATION 9

LABEL

O O

LABEL

OUTLET CONFIGURATION 10

LABEL

G G

G G

R BL

LABEL

OUTLET CONFIGURATION 11

LABEL

R BL

O O

LABEL

OUTLET CONFIGURATION 12

LABEL

O O

O BL

NOTES:

1. NIPR (GREEN), SIPR (RED), & SAP (ORANGE)

OUTLET CONNECTORS SHALL EACH BE

KEYED DIFFERENTLY FROM EACH OTHER

WHICH ARE NOT IN LOCKING PROTECTIVE

ENCLOSURES WITH COVER/DOOR. IN LIEU OF

KEYED CONNECTORS PROVIDE WITH PASS

THRU COVER/DOOR WITH LOCKING MEANS.

2. FOR OUTLETS & PATCH PANELS PROVIDE

CONNECTORS WITH LOCKING MECHANISM

BUILT INTO THE BODY OF THE CONNECTOR

WHICH CANNOT BE RELEASED WITHOUT A

MATCHING COLOR EXTRACTION TOOL.

3. FOR OUTLETS & PATCH PANELS PROVIDE

SECURE PORT BLOCKERS WHICH LOCK AND

PROTECT UNUSED PORTS FROM THE

UNAUTHORIZED INSERTION OF A CABLE

ASSEMBLY OR CONNECTOR. PROVIDE FOR

ALL PORTS SINCE WORK AREA CABLES ARE

(NIC)

RECESSED MOUNTED FIBER

TERMINATION ENCLOSURE

LEGRAND CAT. NO. EHWB4

WITH EHWBC4-WH COVER

12 EA. DUPLEX LC ADAPTERS

12 EA. DUPLEX LC ADAPTERS

1 1/4" CONDUIT WITH

COMPRESSION CONNECTOR

FROM WALKERDUCT IN FLOOR

1 1/4" CONDUIT WITH

COMPRESSION CONNECTOR

FROM CABLE TRAY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

BIM 360://Ellsworth B21/8996-13-Ellsworth AFB B21 Simulator_E19.rvt

4/25/2022 8:54:37 AM

T-501

SIM

T E

L E

C O

M D

E T

A

IL

S

B -2

A

D A

L F

L

IG

H T

S

IM

U L A

T O

R F

A C

IL

IT

Y

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E S

U

IT

E

O M

A H

A N

E B

R A

S K

A

J O

A K

E S

J O

A K

E S

D E

L L E

D G

E

T L

/R A

O C

T O

B E

R

W F

R

ADVERTISEMENT - 100% DESIGN

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

O U

T H

D A

K O

T A

P R

O J E

C T

N U

M B

E R

F

X B

M

N.T.S.E6

TYPICAL TELECOM CONDUIT TO CABLE TRAY DETAIL

N.T.S.E1

TYPICAL FLUSH MOUNT DATA/VOIP

FACEPLATE/ADAPTER INSTALLATION DETAIL

N.T.S.A2

RECESSED MOUNTED TELECOM TERMINATION BOX

GENERAL NOTES

1. TRAY DESIGNED FOR HANGING WITH 1/2" DIAMETER

THREADED ROD. MAXIMUM SPAN IS 10'-0".

2. AT SUPPORT POINTS, THREADED ROD MUST BE HUNG

FROM CONCRETE INSERTS, CLAMPS OR DEVICES

THAT ARE SECURELY FASTENED TO THE

INTERMEDIATE GRID OR STRUCTURE SUFFICIENTLY

TO CARRY THE LOAD OF THE TRAY AND ITS

CONTENTS WITH A SAFETY FACTOR OF 3.

3. INSTALL CABLES UNIFORMLY ACROSS DUAL-RAIL.

4. CONTRACTOR IS TO USE EXTRA HANGERS

WHENEVER IN DOUBT OR FOR ANY UNUSUAL

SITUATION WHEN HANGER ROD IS MOUNTED AT

OTHER THAN A SPLICE CONNECTOR POINT ALONG

TRAY, DRILL A 5/8" HOLE VERTICALLY THROUGH THE

SPLINE AND INSERT HANGER ROD WITH NUTS AND

WASHERS. DO NOT DRILL HOLES IN SPINE UNLESS A

HANGER ROD IS USED.

5. WHEN CONNECTING TRAY SECTIONS AT OTHER THAN

HANGING POINTS, USE SPLICE CONNECTORS WITH

NO VERTICAL HOLES.

6. CABLE TRAY SHALL BE INSTALLED WITH ACCESS

FROM EITHER SIDE TO ALLOW CABLE TO BE LAID

DIRECTLY INTO THE SIDES OF THE TRAY IN LIEU OF

PULLING.

7. PULL HEAVY CABLES IN CENTER OF TRAY.

8. DURING AND AFTER INSTALLATION OF CABLE TRAY,

CARE MUST BE TAKEN BY ALL TRADES NOT TO HANG

FROM THE TRAY RUNGS OR WALK ON THE TRAY.

9. ALL NUTS, BOLTS AND WASHERS ARE TO BE

SUPPLIED WITH ALL FITTINGS.

10. IF A SECOND CONTRACOR INSTALLS THE CABLES,

THIS CONTRACTOR MUST FIRST VERIFY THAT THE

CABLE TRAY HAS BEEN SECURELY AND PROPERLY

INSTALLED BY THE FIRST CONTRACTOR PRIOR TO

INSTALLING ANY CABLES.

11. WHEN PULLING CABLE INTO TRAY, SUFFICIENT

ROLLERS AND SHEAVES MUST BE USED SO THAT

NEITHER THE TRAY NOR THE CABLES ARE DAMAGED.

A

M -0

D E

S

IG

N I

S S

U E

D F

O R

P R

IC

IN

G

/2

A

M -0

D E

S

IG

N I

S S

U E

D F

O R

P R

IC

IN

G

/2

A

M -0

G

E N

E R

A L R

E V

IS

IO

N S

/2

17 17 17

16 16 16

ADAL FLIGHT SIMULATOR FACILITY

COMM ROOM 111

2" C (TYP)

17 17 17 17

16 16 16 16

2" C (TYP)

ADAL FLIGHT SIMULATOR FACILITY

SECURITY STORAGE 143

ADAL FLIGHT SIMULATOR FACILITY

SECURITY OFFICE 144

TO 208V RECEPTACLE

MOUNTED ON CABLE TRAY

PROVIDE 4" x 4" WIREWAY

PROVIDE 4" x 4" WIREWAY

120V, 20A

CKT. TR2-31

120V, 20A

CKT. TR2-33

120V, 20A

CKT. TR2-35

120V, 20A

CKT. TR2-37

120V, 20A

CKT. L2-17

120V, 20A

CKT. L2-19

120V, 20A

CKT. L2-21

TO 208V RECEPTACLE

MOUNTED ON CABLE TRAY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

BIM 360://Ellsworth B21/8996-13-Ellsworth AFB B21 Simulator_E19.rvt

4/25/2022 8:54:37 AM

TY601

SIM

S E

C U

R

IT

Y S

Y S

T E

M R

IS

E

R D

IA

G

R A

M

B -2

A

D A

L F

L

IG

H T

S

IM

U L A

T O

R F

A C

IL

IT

Y

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E S

U

IT

E

O M

A H

A N

E B

R A

S K

A

J O

A K

E S

S W

IL

L

IA

M S

D E

L L E

D G

E

T L

/R A

O C

T O

B E

R

W F

R

ADVERTISEMENT - 100% DESIGN

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

O U

T H

D A

K O

T A

P R

O J E

C T

N U

M B

E R

F

X B

M

1. PROVIDE GROUNDING OF ALL EQUIPMENT RACKS,

CONDUIT AND WIREWAYS TO SBB IN COMM. ROOM.

2. REFER TO PLANS FOR LOCATON OF EQUIPMENT.

3. THE CONTRACTOR SHALL PROVIDE RACEWAYS AND

BACK BOXES FOR THE SECURITY SYSTEM AS A BASE

BID. THE SECURITY EQUIPMENT, INCLUDING RACK

AND WIRING SHALL BE INCLUDED AS A BID OPTION.

4. ALL WORK RELATING TO THE BID OPTION:

PROCUREMENT, INSTALLATION, AND

COMMISSIONING OF THE IDS SYSTEM ITSELF MUST

BE DONE BY US CITIZENS.

1. PROVIDE MULTI MODE, TWO STRAND, OM4 TYPE

FIBER OPTIC CABLE ROUTED IN CONDUIT/CABLE

TRAY FROM SECURITY SYSTEM EQUIP. RACK TO NIPR

FIBER OPTIC PATCH PANEL PANEL IN COMM. RM. 144.

2. PROVIDE RACK MTD. CLIENT WORKSTATION PRIMACE

CONTROL UNIT (PCU).

3. NOT USED.

4. PROVIDE NETWORK SWITCH W/ UPLINK MODULE.

5. PROVIDE EXTENDER CHASSIS DRAWER W/ DC

POWER SUPPLY AND POWER DISTRIBUTION PANEL.

6. NOT USED.

7. PROVIDE V5 INPUT MODULE.

8. PROVIDE 3000 VA UPS, 208 VAC IN, 110 VAC OUT

9. PROVIDE BATTERY PACK FOR SMART UPS, 48 VDC.

10. PROVIDE FLOOR MTD. 72"H x 30"D x 24"W EQUIPMENT

RACK WITH LOCKABLE ENCLOSURE, BACKPLANE,

POWER STRIP, AND TAMPER SWITCH.

11. NOT USED

12. PROVIDE 1RU CABLE MANGEMENT PANEL.

13. PROVIDE FOUR PAIR, CAT-6, 24 AWG SOLID Cu

TWISTED PAIR CABLE. ROUTE IN 3/4" CONDUIT.

14. PROVIDE MULTI MODE, TWO STRAND, OM4 TYPE

FIBER OPTIC CABLE ROUTED IN CABLE TRAY FROM

SECURITY SYSTEM EQUIP. RACK TO NIPR FIBER

OPTIC PATCH PANEL PANEL IN COMM. RM. 111.

15. NOT USED

16. PROVIDE 24" x 24" x 6" NEMA 1 WALL MTD.

ENCLOSURE FOR IDS SERVER. PROVIDE SURGE

PROTECTION, GROUND BAR, AND TAMPER SWITCH.

17. PROVIDE NEMA 1 WALL MTD. ENCLOSURE FOR

POWER SUPPLY, SEALED BATTERY, 8 CIRCUIT

POWER DISTRIBUTION MODULE, SURGE

PROTECTION, AND TAMPER SWITCH.

18. 3/4" CONDUITS FOR CABLING TO DOOR

INPUT/OUTPUT MODULES AND 12VDC POWER TO

DOOR INPUT/OUTPUT MODULES AND DOOR STRIKES.

19. PROVIDE 2RU CABLE MANAGEMENT PANEL.

GENERAL SHEET NOTES

SHEET KEYNOTES

N.T.S.A2

SECURITY SYSTEM RISER DIAGRAM

A

M -0

D E

S

IG

N I

S S

U E

D F

O R

P R

IC

IN

G

/2

A

M -0

G

E N

E R

A L R

E V

IS

IO

N S

/2

CAM E01

CAM E02

CAM E03

CAM E04

CAM E05

CAM E06

CAM E07

CAM E08

CAM E09

CAM E10

CAM E11

PROVIDE CAT 6 STP 23 AWG COPPER

CABLE FROM EACH CAMERA TO

DEDICATED PATCH PANEL IN TELECOM.

EQUIPMENT RACK LOCATED IN MAIN

COMM. RM. 106. ROUTE EACH CABLE IN 1"

CONDUIT. EACH CONDUIT SHALL BE

ROUTED UNDERGROUND TO COMM. RM.

106. NO CONDUIT SHALL BE ROUTED

THROUGH ANY SECURE AREA. TERMINATE

TO 16 PORT POE NETWORK SWITCH

MOUNTED IN RACK ADJACENT TO PATCH

PANEL. REFER TO TELECOM. RISER

DIAGRAM T-601.

EXTERIOR - MAIN ENTRY

EXTERIOR - NORTH OF

MAIN ENTRY

EXTERIOR - MECH. RM.

SOUTH

EXTERIOR - NEAR DOOR 116B

EAST

EXTERIOR - NEAR DOOR 146F

EAST

EXTERIOR - NEAR DOOR 146C

NORTHEAST

EXTERIOR - NEAR DOOR 146C

NORTHEAST

EXTERIOR - NEAR DOOR 140B

NORTH

EXTERIOR - NEAR DOOR 155A

NORTHWEST

EXTERIOR - NEAR DOOR 156A

NORTHEAST

EXTERIOR - NEAR DOOR 116A

NORTH

PROVIDE SURGE SURPRESSOR AT

EACH CAMERA LOCATION AND

GROUND TO BLDG. STEEL. (TYP)

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

BIM 360://Ellsworth B21/8996-13-Ellsworth AFB B21 Simulator_E19.rvt

4/25/2022 8:54:37 AM

TY603

SIM

C C

T V

S Y

S T

E M

R

IS

E R

D

IA

G R

A M

B -2

A

D A

L F

L

IG

H T

S

IM

U L A

T O

R F

A C

IL

IT

Y

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E S

U

IT

E

O M

A H

A N

E B

R A

S K

A

J O

A K

E S

S W

IL

L

IA

M S

D E

L L E

D G

E

T L

/R A

O C

T O

B E

R

W F

R

ADVERTISEMENT - 100% DESIGN

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

O U

T H

D A

K O

T A

P R

O J E

C T

N U

M B

E R

F

X B

M

D4

CCTV SYSTEM RISER DIAGRAM

1. REFER TO PLANS FOR LOCATON OF EQUIPMENT.

2. THE CONTRACTOR SHALL PROVIDE RACEWAYS AND

BACK BOXES FOR THE CCTV SYSTEM AS A BASE BID.

THE CCTV EQUIPMENT, INCLUDING CAMERAS, 16

PORT POE NETWORK SWITCH, WIRING, AND

COMMISSIONING SHALL BE INCLUDED AS A BID

OPTION. CAMERAS SHALL BE POE TYPE CAMERAS,

COMPATIBLE WITH THE VICAD SYSTEM, AND ON THE

AIR FORCE APPROVED EQUIPMENT LIST.

3. CONTRACTOR INSTALLING THE SYSTEM SHALL HAVE

A MINIMUM OF 2 YEARS EXPERIENCE INSTALLING

AND MAINTAINING VICADS SYSTEMS AND HAVE

CERTIFIED VICADS TRAINING WITHIN THE LAST 2

YEARS.

4. CCTV SYSTEM SHALL BE MONITORED BY THE BASE

DEFENSE OPERATIONS CENTER (BDOC).

5. ALL WORK RELATING TO THE BID OPTION:

PROCUREMENT, INSTALLATION, AND

COMMISSIONING OF THE CCTV SYSTEM ITSELF MUST

BE DONE BY US CITIZENS.

GENERAL SHEET NOTES

A

M -0

D E

S

IG

N I

S S

U E

D F

O R

P R

IC

IN

G

/2

A

M -0

G

E N

E R

A L R

E V

IS

IO

N S

/2

T-501 TELECOM DETAILS
Sheets
T-501 - TELECOM DETAILS
TY601 SECURITY SYSTEM RISER DIAGRAM
Sheets
TY601 - SECURITY SYSTEM RISER DIAGRAM
TY603 CCTV SYSTEM RISER DIAGRAM
Sheets
TY603 - CCTV SYSTEM RISER DIAGRAM

File details come from the government source that posted it. Updated .