Am-0005_W9128F21R0079.pdf

PDF 4 MB Posted

Attached to
B-21 Formal Training Unit/AMU (FTU), Ellsworth AFB, South Dakota
Solicitation number
W9128F21R0079
Issued by

About this file

This solicitation is for the construction of a B-21 Formal Training Unit/Aircraft Maintenance Unit facility at Ellsworth Air Force Base in South Dakota. The project includes approximately 44,487 square feet of secure aircraft maintenance space, 43,776 square feet of secure squadron operations space, and 5,000 square feet of non-secure flight kitchen space. Additional site work, demolition, utilities and infrastructure are required. Optional bid items include furniture, intrusion detection systems, access control systems and closed-circuit television systems. Facilities must be designed according to DoD and Air Force standards for permanent construction and incorporate sustainable materials and techniques where feasible. The project will also comply with DoD antiterrorism and force protection requirements. The solicitation is issued by the Department of the Army Corps of Engineers Omaha District.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

W9128F

B-21: FORMAL TRAINING UNIT/AMU (FTU), PN FXBM1093477, FY22, ELLSWORTH AFB, SOUTH DAKOTA

See attached documentation for content of the amendment revisions to solicitation

Date for receipt of Volume II proposals is 6 DEC 2021 at 1400 hours CST

Government Point of Contact: Katherine Fisher, Contract Specialist, Katherine.K.Fisher@usace.army.mil

U.S.ARMY CORPS OF ENGINEERS, OMAHA

Contracting Division (CENWO-CT) 1616 Capitol Ave Omaha, Nebraska 68102-4901

See Item 6

W9128F21R0079

11/23/2021

08/24/2021

11/23/2021

Am #0005 - 1

Am #0005 - 2 (Continuation SF 30)

23 NOV 2021

Solicitation No. W9128F 21 R 0079

Date of Issue: 24 AUG 2021 Date of Receiving Volume II Proposal: 6 DEC 2021

SUBJECT: Amendment No. 0005 to Request for Proposal Solicitation Package for Construction of B-21: FORMAL TRAINING UNIT/AMU (FTU), PN FXBM1093477.

TO: Prospective Offerors and Others Concerned

1. The specifications and drawings for subject project are hereby modified as follows (revise all specification indices, attachment lists, and drawing indices accordingly).

a. Specifications. (Descriptive Changes.) NONE

b. Specifications (New and/or Revised and Reissued). Delete and substitute or add specification pages or sections as noted below. The substituted pages or sections are revised and reissued with this amendment. For convenience, on the revised specification pages, changes have been identified with highlighting, all portions of the revised specification pages apply regardless of whether changes are shown with highlighting.

Pages or Sections Deleted Pages or Sections Substituted or Added 09 06 00 09 06 00 10 28 13 10 28 13 ** 12 24 13 (new section added) ** 12 50 00.13 10AT1 – FF&E Package (new attachment added) 27 41 16 27 41 16

c. Drawings (Reissued). The following drawings are revised with latest revision date as shown in the drawing border and reissued with this amendment.

VOLUME I OF II:

(1) Sheet CS101, SITE PLAN

(2) Sheet CS102, SITE PLAN

(3) Sheet C-501, CIVIL DETAILS

(4) Sheet S-401, ENLARGED UTILITY YARD PLANS

(5) Sheet S-506, FOUNDATION DETAILS - SHEET 4

(6) Sheet S-510, TYPICAL MASONRY DETAILS

(7) Sheet A-002, WALL TYPES

(8) Sheet AE103, FIRST FLOOR PLAN -AREA A

(9) Sheet AE104, FIRST FLOOR PLAN -AREA B

(10) Sheet AE108, SECOND FLOOR PLAN -AREA B

(11) Sheet AE116, SECOND FLOOR REFLECTED CEILING PLAN -AREA A

(12) Sheet AE117, SECOND FLOOR REFLECTED CEILING PLAN -AREA B

(13) Sheet AE201, BUILDING ELEVATIONS

(14) Sheet AE202, BUILDING ELEVATIONS

Am #0005 - 3 (Continuation SF 30)

(15) Sheet AE309, WALL SECTIONS

(16) Sheet AE310, WALL SECTIONS

(17) Sheet AE311, WALL SECTIONS

(18) Sheet AE312, WALL SECTIONS

(19) Sheet AE404, ENLARGED PLANS

(20) Sheet AE405, ENLARGED PLANS

(21) Sheet AE502, DETAILS

(22) Sheet AE503, DETAILS

(23) Sheet AE505, CONTROLLED AREA DETAILS

(24) Sheet AF001, FINISH MATERIALS LIST

(25) Sheet AF601, ROOM FINISH SCHEDULE

(26) Sheet AF602, ROOM FINISH SCHEDULE

(27) Sheet AF603, ROOM FINISH SCHEDULE

VOLUME II OF II:

(1) Sheet M-402, MECHANICAL ENLARGED PLANS

(2) Sheet M-603, MECHANICAL SCHEDULES

(3) Sheet T-501, TELECOMMUNICATIONS DETAILS

(4) Sheet AV101B, 1ST FLOOR PART PLAN B - AV SERVICE LAYOUT

(5) Sheet AV307, AV RISER DIAGRAMS

(6) Sheet AV412, AV SIGNAL FLOW DIAGRAMS

(7) Sheet AV601, AV PLATE & PANEL DETAILS

(8) Sheet AV602, AV PLATE & PANEL DETAILS

(9) Sheet AV603, AV PLATE & PANEL DETAILS

2. This amendment is a part of the proposing papers and its receipt shall be acknowledged. All other conditions and requirements of the request for proposal remain unchanged.

3. Electronic Proposals. Provide proposals via the instructions provided in Section 00 22 00 of the Request for Proposal.

4. Offers will be received until 2:00 p.m. CST on 6 DEC 2021.

Attachments:

Specifications listed in 1.b., above Drawings listed in 1.c., above (Volumes I and II, each provided under separate cover)

U.S. Army Corps of Engineers, Omaha District 1616 Capitol Avenue Omaha, Nebraska 68102-4901

23 NOV 2021

nep/2160

This page was intentionally left blank for duplex printing.

B-21-Formal Training Unit/AMU (FTU) , Ellsworth AFB, SD EL96

SECTION TABLE OF CONTENTS

DIVISION 09 - FINISHES

SECTION 09 06 00

SCHEDULES FOR FINISHES

05/09

PART 1 GENERAL

1.1 SUMMARY

PART 2 PRODUCTS

2.1 COLOR SCHEDULE

2.2 EXTERIOR FINISHES

2.2.1 Exterior Walls

2.2.1.1 Concrete Masonry Units (Rock/Split-Faced)

2.2.1.2 Composite Metal Wall Panels, Hardware, and Associated Trim

2.2.1.3 Glass and Glazing

2.2.2 Exterior Trim

2.2.2.1 Aluminum Doors and Door Frames

2.2.2.2 Aluminum Windows (mullion, muntin, sash, trim, and sill)

2.2.2.3 Fascia

2.2.2.4 Soffits and Ceilings

2.2.2.5 Downspouts and Gutters

2.2.2.6 Handrails

2.2.2.7 Guardrails

2.2.2.8 Bollards

2.2.2.9 Signage

2.2.3 Exterior Roof

2.2.3.1 Metal

2.3 INTERIOR FINISHES

2.3.1 Interior Floor Finishes

2.3.1.1 Carpet Tile

2.3.1.2 Vinyl Composition Tile

2.3.1.3 Luxury Vinyl Tile

2.3.1.4 Resilient Flooring

2.3.1.5 Static-Control Resilient Flooring (Static-Dissipative

Vinyl Tile)

2.3.1.6 Stair Flooring

2.3.1.7 Stair Landings

2.3.1.8 Porcelain Tile

2.3.1.9 Grout

2.3.1.10 Solid Surface Transition

2.3.1.11 Concrete

2.3.1.12 Industrial Floor Coating

2.3.2 Interior Base Finishes

2.3.2.1 Resilient Base and Moldings

2.3.2.2 Porcelain Tile

2.3.2.3 Grout

2.3.3 Interior Wall Finishes

2.3.3.1 Paint

2.3.3.2 Porcelain Tile

SECTION 09 06 00 Page 1Am #0005

2.3.3.3 Grout

2.3.4 Interior Ceiling Finishes

2.3.4.1 Acoustical Tile and Grid

2.3.4.2 Paint (Ceilings)

2.3.4.3 Paint (Soffits)

2.3.5 Interior Trim

2.3.5.1 Aluminum Doors and Door Frames

2.3.5.2 Aluminum Windows (mullion, muntin, sash, trim, and stool)

2.3.5.3 Wood Doors

2.3.5.4 Wood Stain

2.3.5.5 Handrails

2.3.5.6 Guardrails

2.3.5.7 Exposed Ductwork

2.3.6 Interior Window Treatment

2.3.7 Interior Miscellaneous

2.3.7.1 Toilet Partitions and Urinal Screens

2.3.7.2 Plastic Laminate

2.3.7.3 Solid Surfacing Material

2.3.7.4 Window Sills (Solid Surface)

2.3.7.5 Signage Message Color

2.3.7.6 Signage Background Color

2.3.7.7 Stair Stringers

PART 3 EXECUTION

-- End of Section Table of Contents --

SECTION 09 06 00 Page 2Am #0005

SECTION 09 06 00

SCHEDULES FOR FINISHES

05/09

PART 1 GENERAL

1.1 SUMMARY

This section covers only the color of exterior and interior materials and products that are exposed to view in the finished construction. The word "color", as used herein, includes surface color and pattern. Requirements for quality, product specifications, and method of installation are covered in other appropriate sections of the specifications. Specific locations where the various materials are required are shown on the drawings if not identified in this specification. Items not designated for color in this section may be specified in other sections. When color is not designated for items, propose a color for approval.

PART 2 PRODUCTS

2.1 COLOR SCHEDULE

The color schedule information provided in the following paragraphs lists the colors, patterns and textures required for exterior and interior finishes, including both factory applied and field applied colors. Where color is shown as being specific to one manufacturer, an equivalent color by another manufacturer may be submitted for approval. Manufacturers and materials specified are not intended to limit the selection of equal colors from other manufacturers. In the case of difference between the drawings and specifications, colors identified in this specification govern.

2.2 EXTERIOR FINISHES

Reference drawings for manufacturer and color information.

2.2.1 Exterior Walls

Exterior wall colors apply to exterior wall surfaces including recesses at entrances and projecting vestibules. When applicable, paint conduit to closely match the adjacent surface color. Provide wall colors to match the colors listed below.

2.2.1.1 Concrete Masonry Units (Rock/Split-Faced)

CMU-1 Westbrook Concrete, Color: SF355.

CMU-2 Westbrook Concrete, Color: SF137.

2.2.1.2 Composite Metal Wall Panels, Hardware, and Associated Trim

Alucobond/Alucobond Classic, Style: Rainscreen, Color: Anodic clear mica PVDF-2, Finish: Matte.

SECTION 09 06 00 Page 3Am #0005

2.2.1.3 Glass and Glazing

Clear

2.2.2 Exterior Trim

Provide exterior trim to match the colors listed below.

2.2.2.1 Aluminum Doors and Door Frames

Kawneer, Color: Clear anodized, Finish: Matte.

2.2.2.2 Aluminum Windows (mullion, muntin, sash, trim, and sill)

Kawneer, Color: Clear anodized, Finish: Matte.

2.2.2.3 Fascia

Factory finish, color to match standing seam metal roof.

2.2.2.4 Soffits and Ceilings

Factory finish, color to match composite metal wall panel.

2.2.2.5 Downspouts and Gutters

Factory finish, color to match standing seam metal roof.

2.2.2.6 Handrails

Galvanized steel with factory finish, Color: Dark Bronze.

2.2.2.7 Guardrails

Galvanized steel with factory finish, Color: Dark Bronze.

2.2.2.8 Bollards

Paint safety yellow.

2.2.2.9 Signage

Backgorund: Dark brown, Lettering: Reflective white.

2.2.3 Exterior Roof

Apply roof color to exterior roof surfaces including sheet metal flashings and copings, snow guards, mechanical units, mechanical penthouses, roof trim, pipes, conduits, electrical appurtenances, and similar items.

Provide roof color to match the colors listed below.

2.2.3.1 Metal

Berridge/Tee-Panel, Color: Dark Bronze

SECTION 09 06 00 Page 4Am #0005

2.3 INTERIOR FINISHES

2.3.1 Interior Floor Finishes

Provide flooring materials to match the colors listed below.

2.3.1.1 Carpet Tile

CPT-1: Patcraft/Gemscape, Style: Surface striation color, Color:

00460 Opal, Size: 24 inches by 24 inches, Installation: Monolithic.

CPT-2: Patcraft/Gemscape, Style: Inclusion color, Color: 00460 Opal, Size: 24 inches by 24 inches, Installation: Quarter turn.

2.3.1.2 Vinyl Composition Tile

VCT-1: Tarkett/IQ Granit, Color: 382 Yoga, Size: 24 inches by 24 inches.

VCT-2: Tarkett/IQ Granit SD, Color: 726 Sidewalk, Size: 24 inches by 24 inches.

2.3.1.3 Luxury Vinyl Tile

LVT-1: Armstrong/Unbound, Color: Thunder Hill Hickory Storm Cloud F0703, Size: 7 inches by 59 inches.

[*Am-5]

2.3.1.4 Resilient Flooring

RF-1: Roppe, 978 Smooth [**Am-5], Color: M123 Charcoal.

2.3.1.5 Static-Control Resilient Flooring (Static-Dissipative Vinyl Tile)

VCT-2

2.3.1.6 Stair Flooring

[*Am-5] TR-1 (Treads & Risers): Roppe, Texture: 965 Raised Circular Vantage, Color: M123 Charcoal [**Am-5]

2.3.1.7 Stair Landings

RF-1

2.3.1.8 Porcelain Tile

T-1: Daltile/Portfolio, Color: PF06 Iron Gray, Size: 12 inches by 24 inches, Installation: Staggered brick work, GRT-1.

2.3.1.9 Grout

GRT-1: Bostik/Quartzlock 2, Color: Silver Gray 320.

2.3.1.10 Solid Surface Transition

SSM-1: Corian/Silver Birch.

SECTION 09 06 00 Page 5Am #0005

[*Am-5]

2.3.1.4 Resilient Flooring

RF-1: Roppe, 978 Smooth [**Am-5], [*Am-5] TR-1 (Treads & Risers): Roppe, Texture: 965 Raised Circular Vantage, Color: M123 Charcoal [**Am-5]

2.3.1.11 Concrete

SC-1: Sealed

2.3.1.12 Industrial Floor Coating

DS-1: Euclid Chemicals/Surflex, Color: Battleship Gray.

2.3.2 Interior Base Finishes

Provide base materials to match the colors listed below.

2.3.2.1 Resilient Base and Moldings

RB-1: Roppe/700 Series, Color: 123 Charcoal, Height: 4 inches.

2.3.2.2 Porcelain Tile

TB-1: Daltile/Portfloio, Color: PF06 Iron Gray, Size: 6 inches by 12 inches, Installation: Straight, GRT-1.

2.3.2.3 Grout

GRT-1

2.3.3 Interior Wall Finishes

Apply interior wall color to the entire wall surface, including reveals, vertical furred spaces and columns, grilles, diffusers, electrical and access panels, and piping and conduit adjacent to wall surfaces unless otherwise specified. Paint items not specified in other paragraphs to match adjacent wall surface. Provide wall materials to match the colors listed below.

2.3.3.1 Paint

P-1: Sherwin Williams/ 5W7006 Extra White.

P-2: Sherwin Williams/ SW 6233 Samovar Silver.

P-3: Sherwin Williams/SW7007 Ceiling Bright White.

P-4: Sherwing Williams/ SW7674 Peppercorn.

2.3.3.2 Porcelain Tile

T-2: Daltile/Portfolio, Color: PF04 Dove Grey, Sixe: 12 inches by 24 inches, Installation: Staggered brick work, GRT-1.

T-3: Daltile/Color Wheel Mosaic, Style: Lattice Weave, Color:

Nav4K189, Installation: Straight, GRT-1.

T-4: Daltile/Portfolio, Color: PF04 Dove Grey, Size: 3 inches by 12 inches, Installation: Straight, GRT-1.

2.3.3.3 Grout

GRT-1

SECTION 09 06 00 Page 6Am #0005

2.3.4 Interior Ceiling Finishes

Apply ceiling colors to ceiling surfaces including soffits, furred down areas, grilles, diffusers, registers, and access panels. In addition, apply ceiling color to joists, underside of roof deck, and conduit and piping where joists and deck are exposed and required to be painted.

Provide ceiling materials to match the colors listed below.

2.3.4.1 Acoustical Tile and Grid

ACT-1: Armstrong/Ultima Beveled, 24 inches by 24 inches.

2.3.4.2 Paint (Ceilings)

Match P-3.

2.3.4.3 Paint (Soffits)

Match P-3.

2.3.5 Interior Trim

Provide interior trim to match the colors listed below.

2.3.5.1 Aluminum Doors and Door Frames

Match P-4.

2.3.5.2 Aluminum Windows (mullion, muntin, sash, trim, and stool)

Match P-4.

2.3.5.3 Wood Doors

Match WD-1.

2.3.5.4 Wood Stain

WD-1: Sherwin Williams/ MW429 Sawyer.

2.3.5.5 Handrails

Match P-4.

2.3.5.6 Guardrails

Match P-4.

2.3.5.7 Exposed Ductwork

Match P-3.

2.3.6 Interior Window Treatment

Provide window treatments to match the colors listed below.

2.3.7 Interior Miscellaneous

Provide miscellaneous items to match the colors listed below.

SECTION 09 06 00 Page 7Am #0005

2.3.7.1 Toilet Partitions and Urinal Screens

TP-1: Scranton Products/Hiny Hiders, Color: Midnight, Texture:

Orange Peel.

US-1: Match TP-1.

2.3.7.2 Plastic Laminate

PLAM-1: Formica/Blue Felt 9320-58, Matte Finish.

PLAM-2: Wilson Art/ Neo Walnut 7991-38, Fine Velvet Finish.

2.3.7.3 Solid Surfacing Material

SSM-1: Corian/Silver Birch.

2.3.7.4 Window Sills (Solid Surface)

Match SSM-1.

2.3.7.5 Signage Message Color

Match P-3.

2.3.7.6 Signage Background Color

Match P-4.

[*Am-5]

2.3.7.7 Stair Stringers

Paint to match P-4. [**Am-5]

PART 3 EXECUTION

Not Used

-- End of Section --

SECTION 09 06 00 Page 8Am #0005

[*Am-5]

2.3.7.7 Stair Stringers

Paint to match P-4. [**Am-5]

DIVISION 10 - SPECIALTIES

SECTION 10 28 13

TOILET ACCESSORIES

08/17

PART 1 GENERAL

1.1 SUBMITTALS

1.2 DELIVERY, STORAGE, AND HANDLING

1.3 WARRANTY

PART 2 PRODUCTS

2.1 MANUFACTURED UNITS

2.1.1 Anchors and Fasteners

2.1.2 Finishes

2.2 ACCESSORY ITEMS

2.2.1 Grab Bar (GB)

2.2.2 Sanitary Napkin Disposer (SND)

2.2.3 Electric Hand Dryer (EHD)

2.2.4 Mop and Broom Holder (MH)

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Recessed Accessories

3.1.2 Surface Mounted Accessories

3.2 CLEANING

SECTION 10 28 13 Page 1Am #0005

SECTION 10 28 13

TOILET ACCESSORIES

08/17

PART 1 GENERAL

1.1 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Finishes; G, AE

Accessory Items; G, AE

Recycled content for stainless steel toilet accessories; S, AE

SD-04 Samples

Finishes; G, RO

Accessory Items; G, RO

SD-07 Certificates

Accessory Items; G, RO

SD-10 Operation and Maintenance Data

Electric Hand Dryer; G, RO

1.2 DELIVERY, STORAGE, AND HANDLING

Wrap toilet accessories for shipment and storage, then deliver to the jobsite in manufacturer's original packaging, and store in a clean, dry area protected from construction damage and vandalism.

1.3 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.

PART 2 PRODUCTS

2.1 MANUFACTURED UNITS

Provide toilet accessories where indicated in accordance with paragraph

SECTION 10 28 13 Page 2Am #0005

SCHEDULE. Porcelain type, tile-wall accessories are specified in Section 09 30 10 CEMENT TILING, QUARRY TILING, AND PAVER TILING. Provide each accessory item complete with the necessary mounting plates of sturdy construction with corrosion resistant surface.

Provide stainless steel products listed herein manufactured from materials containing a minimum of 50 percent recycled content. Provide data identifying percentage of recycled content for stainless steel toilet accessories.

2.1.1 Anchors and Fasteners

Provide anchors and fasteners capable of developing a restraining force commensurate with the strength of the accessory to be mounted and suited for use with the supporting construction. Provide tamperproof design oval heads exposed fasteners with finish to match the accessory.

2.1.2 Finishes

Except where noted otherwise, provide the following finishes on metal:

Metal Finish

Stainless steel No. 4 satin finish

Carbon steel, copper alloy, and brass Chromium plated, bright

2.2 ACCESSORY ITEMS

Conform to the requirements for accessory items specified below. Submit fasteners proposed for use for each type of wall construction, mounting, operation, and cleaning instructions and one sample of each other accessory proposed for use. Incorporate approved samples into the finished work, provided they are identified and their locations noted.

Submit certificate for each type of accessory specified, attesting that the items meet the specified requirements.

2.2.1 Grab Bar (GB)

Provide an 18 gauge, 1-1/4 inch grab bar OD Type 304 stainless steel.

Provide form and length for grab bar as indicated. Provide concealed mounting flange. Provide grab with satin finish. Furnish installed bars capable of withstanding a 500 pound vertical load without coming loose from the fastenings and without obvious permanent deformation. Allow 1-1/2 inch space between wall and grab bar.

2.2.2 Sanitary Napkin Disposer (SND)

Construct a Type 304 stainless steel sanitary napkin disposal with removable leak-proof receptacle for disposable liners. Provide fifty disposable liners of the type standard with the manufacturer. Retain receptacle in cabinet by tumbler lock. Provide disposer with a door for inserting disposed napkins, partition mounted, double access.

[*Am-5] <text deleted> [**Am-5]

SECTION 10 28 13 Page 3Am #0005

[*Am--5] <text deleted> [**Am--5]

2.2.3 Electric Hand Dryer (EHD)

Provide wall mount and electric hand dryer designed to operate at 110/125 volts, 60 cycle, single phase alternating current with a heating element core rating of a maximum 2100 watts. Provide dryer housing of single piece construction and of baked electrostatically applied epoxy. Submit 4 complete copies of maintenance instructions listing routine maintenance procedures and possible breakdowns. Include repair instructions for simplified wiring and control diagrams and other information necessary for unit maintenance.

2.2.4 Mop and Broom Holder (MH)

Stainless steel with grip jaw cam mechanism securing 5 mop or broom handles. Also includes hooks and storage shelf.

PART 3 EXECUTION

3.1 INSTALLATION

Do not install items that show visual evidence of biological growth.

Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory. Provide oval exposed screw heads. Install accessories at the location and height indicated. Protect exposed surfaces of accessories with strippable plastic or by other means until the installation is accepted. After acceptance of accessories, remove and dispose of strippable plastic protection. Coordinate accessory manufacturer's mounting details with other trades as their work progresses. Use sealants for brackets, plates, anchoring devices and similar items in showers (a silicone or polysulfide sealant) as they are set to provide a watertight installation. After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace with new work.

3.1.1 Recessed Accessories

Fasten accessories with wood screws to studs, blocking or rough frame in wood construction. Set anchors in mortar in masonry construction. Fasten to metal studs or framing with sheet metal screws in metal construction.

3.1.2 Surface Mounted Accessories

Mount on concealed backplates, unless specified otherwise. Conceal fasteners on accessories without backplates. Install accessories with sheet metal screws or wood screws in lead-lined braided jute, PTFE or neoprene sleeves, or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction. Install backplates in the same manner, or provide with lugs or anchors set in mortar, as required by the construction. Fasten accessories mounted on gypsum board and plaster walls without solid backing into the metal or wood studs or to solid wood blocking secured between wood studs, or to metal backplates secured to metal studs.

3.2 CLEANING

Clean material in accordance with manufacturer's recommendations. Do not use alkaline or abrasive agents. Take precautions to avoid scratching or marring exposed surfaces.

SECTION 10 28 13 Page 4Am #0005

-- End of Section --

SECTION 10 28 13 Page 5Am #0005

DIVISION 12 - FURNISHINGS

SECTION 12 24 13

ROLLER WINDOW SHADES

08/17

PART 1 GENERAL

1.1 GENERAL REQUIREMENTS

1.2 REFERENCES

1.3 SUBMITTALS

1.4 CERTIFICATES

1.4.1 Indoor Air Quality Certifications

1.4.1.1 Roller Window Shades

1.5 QUALITY ASSURANCE

1.5.1 Qualifications

1.5.1.1 Manufacturer's Qualifications

1.5.1.2 Installer's Qualifications

1.5.2 Flammability Requirements

1.5.3 Electrical Requirements

1.5.4 Anti-Microbial Requirements

1.6 DELIVERY, STORAGE, AND HANDLING

1.7 WARRANTY

PART 2 PRODUCTS

2.1 WINDOW SHADES

2.1.1 Light Filtering Shades

2.1.2 Room Darkening Shades

2.2 COLOR

PART 3 EXECUTION

3.1 FIELD MEASUREMENTS

3.2 ROLLER WINDOW SHADE PLACEMENT SCHEDULE

3.3 INSTALLATION

3.4 CLEAN-UP

SECTION 12 24 13 Page 1Am #0005

SECTION 12 24 13

ROLLER WINDOW SHADES

08/17

PART 1 GENERAL

1.1 GENERAL REQUIREMENTS

Provide roller window shades, complete with necessary brackets, fittings, and hardware as indicated. Mount and operate equipment in accordance with manufacturer's instructions. Windows to receive a shade must be completely covered.

a. Submit drawings showing plans, elevations, sections, product details, installation details, operational clearances, wiring diagrams and relationship to adjacent work. Include the use of same room designations as indicated on the drawings.

b. Provide manufacturer's data composed of catalog cuts, brochures, product information, and operating and maintenance instructions on each product to be used. Include styles, profiles and features.

c. Furnish samples of each type and color of roller shade fabric and roller shade channel. Shade material shall be minimum6 by 6 inch in size. Mark face of material to indicate interior faces.

d. Mock up: Install shade in area designated by Contracting Officer. Do not proceed with remaining work until the Contracting Officer approves workmanship and operation. Re-work mock-up as required to produce acceptable work. The approved shade can be used in installation.

e. Submit fire resistance data, flame spread and smoke contribution data.

1.2 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 701 (2019) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

SECTION 12 24 13 Page 2Am #0005

UNDERWRITERS LABORATORIES (UL)

UL 325 (2017; Reprint Feb 2020) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES

SD-02 Shop Drawings

Installation; G, AE

SD-03 Product Data

Window Shades; G, AE

Recycled Content for various fiber components; S, AE

SD-04 Samples

Window Shades; G, RO

SD-06 Test Reports

Window Shades

SD-07 Certificates

Indoor Air Quality for roller window shades; S, AE

SD-08 Manufacturer's Instructions

Window Shades

SD-10 Operation and Maintenance Data

Window Shades

SD-11 Closeout Submittals

Warranty; G, RO

SECTION 12 24 13 Page 3Am #0005

1.4 CERTIFICATES

1.4.1 Indoor Air Quality Certifications

1.4.1.1 Roller Window Shades

Provide products certified to meet indoor air quality requirements by UL 2818 Greenguard Gold, SCS Global Services Indoor Advantage Gold or provide validation by other third-party program that products meet the requirements of this paragraph. Provide current product certification documentation from certification body.

1.5 QUALITY ASSURANCE

1.5.1 Qualifications

1.5.1.1 Manufacturer's Qualifications

Obtain motor-controlled roller shades through one source from a single manufacturer with a minimum of twenty years experience and minimum of three projects of similar scope and size in manufacturing products comparable to those specified in this section.

1.5.1.2 Installer's Qualifications

Installer trained and certified by the manufacturer with a minimum of ten years experience in installing products comparable to those specified in this section.

1.5.2 Flammability Requirements

Passes in accordance with NFPA 701 small and large-scale vertical burn.

Materials tested must be identical to products proposed for use.

1.5.3 Electrical Requirements

NFPA Article 100 listed and labeled in accordance with UL 325 or other testing agency acceptable to authorities having jurisdiction, marked for intended use, and tested as a system. Individual testing of components will not be acceptable in lieu of system testing.

1.5.4 Anti-Microbial Requirements

'No Growth' per ASTM G21 results for fungi ATCC9642, ATCC 9644, ATCC9645.

1.6 DELIVERY, STORAGE, AND HANDLING

Deliver components to the jobsite in the manufacturer's original packaging with the brand or company name, item identification, and project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 50 degrees F. Do not open containers until needed for installation unless verification inspection is required.

1.7 WARRANTY

Provide 10 year minimum limited warranty.

SECTION 12 24 13 Page 4Am #0005

PART 2 PRODUCTS

2.1 WINDOW SHADES

Roller tube must operate smoothly and be of sufficient diameter and thickness to prevent excessive deflection. Provide brackets that are appropriate for inside mount. The shade cloth must meet the performance described in NFPA 701, small scale test. Treat steel features for corrosion resistance.

Provide Various Fiber Components with a minimum of 60 percent recycled content. Provide data identifying percentage of recycled content for various fiber components.

Provide certification of indoor air quality for roller window shades.

2.1.1 Light Filtering Shades

Provide light filtering window shades to conform with the following:

a. Roller tube must be extruded aluminum or steel. Diameter, wall thickness, and material to be selected by the manufacturer to accommodate the shade size. Provide roller idler assembly of molded nylon and zinc-plated steel pin. Sliding pin must allow easy installation and removal of roller. Fabric must be connected to the roller tube with double sided adhesive specifically developed to attach coated textiles to metal to eliminate horizontal impressions in fabric or attached with a spline lock system.

b. Fascia must be L-shaped aluminum extrusion to conceal shade roller and hardware that snaps onto end caps without requiring exposed fasteners of any kind. Fascia can be mounted continuously across two or more shade bands.

c. End caps must be stamped steel with universal design suitable for mounting to window mullions. Provide size compatible with roller size. End cap covers must match fascia/headbox finish.

d. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component without requiring removal of brackets and end or center supports. Provide hardware system that allows for operation of multiple shade bands by a single operator. Connectors must be offset to assure alignment from the first to the last shade band. Provide shade hardware constructed of minimum 1/8 inch thick plated steel or heavier as required to support 150 percent of the full weight of each shade.

e. Manual Operated Chain Drive Hardware must provide for universal, regular and offset drive capacity, allowing drive chain to fall at front, rear or non-offset for all shade drive end brackets. Universal offset must be adjustable for future change. Provide positive mechanical engagement of drive mechanism to shade roller tube. The drive bracket must be fully integrated with all accessories. Drive chain must be #10 stainless steel chain rated to 110 lb. minimum breaking strength.

SECTION 12 24 13 Page 5Am #0005

2.1.2 Room Darkening Shades

Provide room darkening (black-out) window shades designed to eliminate all visible light gaps when shades are fully closed, and conform with the following:

a. Roller tube must be aluminum, controlled by crank operated gear box with steel rods. Provide shop fabricated light traps, consisting of a head box to house the shade roller, and U-shaped channels to serve as guides for the shade along the sides and to receive the bottom edge of the shade along the sill.

b. Provide light trap made of sheet steel having a minimum thickness of 22 gauge or anodized, extruded, aluminum. The legs of the channels must be not less than 1-3/4 inches long and separated by the minimum distance that will permit free operation of the shade. Edges of light trap coming into contact with the shade cloth must be smooth pile light seal. The exposed face of the head box must be hinged or removable for access to the shade roller. The interior or unexposed surfaces of the light trap must have a finish coat of flat black enamel. The exposed portions of the light trap must have a factory-applied priming coat of gray paint.

c. Cloth must be of type for blackout purposes. Make the shade from a single piece of 36% fiberglass, 64% vinyl. When not finished with a selvage, the vertical edges of the shade must be bound or hemmed using a high-grade thread. Make needle holes lightproof by applying a suitable filler.

d. Fit the bottom edge of the shade with a steel operating bar. Shades will engage positively with bottom rail through operating bar or chain pull. Paint bars with flat black enamel. Make pull cords of No. 4 braided nylon or beaded chain having not less than 175 pounds breaking strength.

2.2 COLOR

Provide color, pattern and texture for metal and shade fabric in accordance with Section 09 06 00 SCHEDULES FOR FINISHES.. Color listed is not intended to limit the selection of equal colors from other manufacturers. Openness factor of WS-1 fabric must be 5 percent. Openness factor of WS-2 fabric must be 0 percent.

PART 3 EXECUTION

3.1 FIELD MEASUREMENTS

After becoming familiar with details of the work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the work.

3.2 ROLLER WINDOW SHADE PLACEMENT SCHEDULE

Provide window covering as follows:

SECTION 12 24 13 Page 6Am #0005

Room Number/Name Roller Window Shade Covering Type

Window Type/Size Window Quantity

1008 0% A5 6

1009 0% A5 6

2083 0% E1 2

2079 5% E3 4

2079 5% F6 7

3.3 INSTALLATION

Do not install building construction materials that show visual evidence of biological growth.

Perform installation in accordance with the approved detail drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units.

Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installation until completion of room painting and finishing operations.

3.4 CLEAN-UP

Upon completion of the installation, clean window treatments and adjust them for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate metal parts from direct contact with concrete, mortar, or dissimilar metals. Ensure shades installed in recessed pockets can be removed without disturbing the pocket. The entire shade, when retracted, must be contained inside the pocket. For shades installed outside the jambs and mullions, overlap each jamb and mullion 0.75 inch or more when the jamb and mullion sizes permit. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.

-- End of Section --

SECTION 12 24 13 Page 7Am #0005

CUI

100% SUBMITTAL

FF&E PACKAGE

B-21: FORMAL TRAINING UNIT/AMU (FTU)

P.N. FXBM1093477 FY 2022

ELLSWORTH AFB, SD

Solicitation No. W9128F21R0079

Prepared by: Prepared for:

Am #0005 12 50 00.13 10AT1 Page 1 of 426

This page intentionally left blank.

Am #0005 12 50 00.13 10AT1 Page 2 of 426

Ellsworth AFB, SD

Project Number: FXBM1093477

September 2021

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 3 of 426

Am #0005 12 50 00.13 10AT1 Page 4 of 426

SECTION 1

FFE TABLE OF CONTENTS

SECTION 1 TABLE OF CONTENTS

SECTION 2 BEST VALUE STATEMENT

SECTION 3 UNICOR WAIVER

SECTION 4 POINTS OF CONTACT LIST

SECTION 5 LOCATION CODES AND COST ESTIMATE

SECTION 6 MANUFACTURER'S LIST

SECTION 7 ACCESSORIES

SECTION 8 CHAIRS AND SEATING (ALL KINDS)

SECTION 9 DESKS (ALL KINDS)

SECTION 10 EQUIPMENT

SECTION 11 FILES & STORAGE (ALL KINDS)

SECTION 12 TABLES (ALL KINDS)

SECTION 13 FURNITURE SYSTEMS

SECTION 14 FURNITURE PLACEMENT PLANS

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 5 of 426

Am #0005 12 50 00.13 10AT1 Page 6 of 426

SECTION 2

BEST VALUE STATEMENT

FAR 8.4 Tells us that you should make a "Best Value" determination before placing Multiple Award Schedule (MAS) orders above the micro-purchase limit (currently $2500).

For Orders over $2,500, but under the Maximum Order (MO), simply review at least three (3) price lists.

For orders over the MO, review additional price lists GSA Schedules and generally seek a reduced price from those GSA contractors appearing to offer the best value. Orders under $2,500 may be placed with any GSA schedule Contractor.

Yes No The Project Interior Designer reviewed the required number of sources under the Federal Supply Schedule and use the following contractors below in their Market Analysis in determining the what best meets the customers requirements.

Accessories (Waste Receptacles)

X Company A Rubbermaid Company B Zoro Company C United Solutions

Yes No Has the lowest priced item been specified? If NO, indicate the factors considered in the best value decision below:

Price Special features that are required in effective program performance Special features that are provided by a comparable item Trade-In Consideration Probable life of the item selected as compared with a like item Warranty Considerations Maintenance Availability Past Performance(e.g.experience; local dealer) Environmental and energy efficiency consideration Comfort/suitability of the item Delivery Time Administrative costs Training Needed and/or provided Technial Qualifications Compatibility with existing furniture Others (Specify)

Having considered the factors above to choose the item(s) which overall will provide the best value for this customer I have made a best value determination for this furniture package.

Signature of Designer of Record Date:

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 7 of 426

FAR 8.4 Tells us that you should make a "Best Value" determination before placing Multiple Award Schedule (MAS) orders above the micro-purchase limit (currently $2500).

For Orders over $2,500, but under the Maximum Order (MO), simply review at least three (3) price lists.

For orders over the MO, review additional price lists GSA Schedules and generally seek a reduced price from those GSA contractors appearing to offer the best value. Orders under $2,500 may be placed with any GSA schedule Contractor.

Yes No The Project Interior Designer reviewed the required number of sources under the Federal Supply Schedule and use the following contractors below in their Market Analysis in determining the what best meets the customers requirements.

Chairs

X Company D Allseating Company E Steelcase Company F Herman Miller Desks

X Company G Haworth Company H Steelcase Company I Herman Miller Systems Furniture

X Company J Haworth Company K Steelcase Company L Herman Miller

Yes No Has the lowest priced item been specified? If NO, indicate the factors considered in the best value decision below:

Price Special features that are required in effective program performance Special features that are provided by a comparable item Trade-In Consideration Probable life of the item selected as compared with a like item Warranty Considerations Maintenance Availability Past Performance(e.g.experience; local dealer) Environmental and energy efficiency consideration Comfort/suitability of the item Delivery Time Administrative costs Training Needed and/or provided Technial Qualifications Compatibility with existing furniture Others (Specify)

Having considered the factors above to choose the item(s) which overall will provide the best value for this cusomter I have made a best value determination for this furniture package.

Signature of Designer of Record Date:

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 8 of 426

FAR 8.4 Tells us that you should make a "Best Value" determination before placing Multiple Award Schedule (MAS) orders above the micro-purchase limit (currently $2500).

For Orders over $2,500, but under the Maximum Order (MO), simply review at least three (3) price lists.

For orders over the MO, review additional price lists GSA Schedules and generally seek a reduced price from those GSA contractors appearing to offer the best value. Orders under $2,500 may be placed with any GSA schedule Contractor.

Yes No The Project Interior Designer reviewed the required number of sources under the Federal Supply Schedule and use the following contractors below in their Market Analysis in determining the what best meets the customers requirements.

Tables

X Company M Haworth Company N Steelcase Company O Herman Miller Files and Storage (does not include lockers)

X Company P Haworth Company Q Steelcase Company R Herman Miller Equipment

X Company S Frigidaire Company T Whirlpool Company U GE

Yes No Has the lowest priced item been specified? If NO, indicate the factors considered in the best value decision below:

Price Special features that are required in effective program performance Special features that are provided by a comparable item Trade-In Consideration Probable life of the item selected as compared with a like item Warranty Considerations Maintenance Availability Past Performance(e.g.experience; local dealer) Environmental and energy efficiency consideration Comfort/suitability of the item Delivery Time Administrative costs Training Needed and/or provided Technial Qualifications Compatibility with existing furniture Others (Specify)

Having considered the factors above to choose the item(s) which overall will provide the best value for this cusomter I have made a best value determination for this furniture package.

Signature of Designer of Record Date:

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 9 of 426

Am #0005 12 50 00.13 10AT1 Page 10 of 426

SECTION 3

UNICOR WAIVER

A UNICOR WAIVER IS NOT REQUIRED BECAUSE THIS PROJECT IS BUILT ON A DEPARTMENT OF DEFENSE INSTALLATION . THE DEPARTMENT OF DEFENSE IS NOT REQUIRED TO PURCHASE FROM UNICOR.

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 11 of 426

Am #0005 12 50 00.13 10AT1 Page 12 of 426

SECTION 4

POINTS OF CONTACT

Use these Points of Contact to facilitate the FFE ordering and installation

Command Interior Designer

User Group

Lead Vendor/Furniture Installer Patricia Brewster Furniture Marketing Group 421 NW 10th Street, Suite 101C Oklahoma City OK 73103

Prime Construction Contractor TBD

MAILING ADDRESS

Interior Designer of Record Danielle Cavin Blair Remy Architects 7 S. Mickey Mantle Drive, Suite 350 Oklahoma City, Oklahoma 73104

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 13 of 426

Am #0005 12 50 00.13 10AT1 Page 14 of 426

SECTION 5

LOCATION CODES AND COST ESTIMATE

LOCATION CODES AND COST ESTIMATES

B-21 Aircraft Maintenance Shop (FTU)

Am #0005 12 50 00.13 10AT1 Page 15 of 426

Location Codes Catalog Name Contractor

GSA Contract Number QTY

384 PART 2, OFFICE ACCESSORIES

A-1 Wastebasket Rubbermaid Commercial GS-21F-0044W 253 A-2 Recycle Bin Rubbermaid Commercial GS-21F-0035T 253 A-3 23 Gallon Waste Receptacle Rubbermaid Commercial GS-21F-0044W 8 A-4 23 Gallon Recycle Bin Rubbermaid Commercial GS-21F-0044W 8 A-5 50 Gallon Waste Drum Rubbermaid Commercial GS-21F-0044W 9 A-6 50 Gallon Recycle Receptacle Rubbermaid Commercial GS-21F-0044W 9 A-7 Marker Board Ghent Manufacturing 47QSCA20D000C 137 A-8 Anti Fatigue Mat GSA Global Supply N/A 10 A-9 Mirror Hausmann Industries 36F79719D0126 2 A-10 Wall Clock Abilityone 47QSEA20D001S 1

71 PART I, OFFICE CHAIRS

C-1 Executive Task Chair Allseating GS-29F-004AA 2 C-2 Task Chair Allseating GS-29F-004AA 521 C-3 Guest Chair Allseating GS-29F-004AA 49 C-4 Conference Chair Allseating GS-29F-004AA 50 C-5 Side Chair Allseating GS-29F-004AA 66 C-6 Break Chair Allseating GS-29F-004AA 45 C-7 Task Stool Allseating GS-29F-004AA 18 C-8 Sofa Allseating GS-29F-004AA 5 C-9 Lounge Chair Allseating GS-29F-004AA 5 C-10 Reclining Chair Allseating GS-29F-004AA 1 C-11 Lounge Stool Allseating GS-29F-004AA 36 C-12 Locker Room Bench LYON 47QSHA18D000G 1 C-13 Locker Room Bench LYON 47QSHA18D000G 10 C-14 Auditorium Chair Borgo GS-27F-0004T 125 C-15 Stool Allseating GS-29F-004AA 1

71 PART I, OFFICE DESKS

D-1 Executive Private Office Desk Haworth GS-03F-057DA 2 D-2 Private Office Desk with Left Return Haworth GS-03F-057DA 8 D-3 Private Office Desk with Right Return Haworth GS-03F-057DA 4 D-4 Instructor Desk Haworth GS-03F-057DA 2 D-5 Benching System Haworth GS-03F-057DA 4 D-6 Benching System Haworth GS-03F-057DA 2 D-7 Workbench Stanley Black and Decker GS-03F-062GA 2 D-8 Workbench Stanley Black and Decker GS-03F-062GA 1 D-9 Workbench Stanley Black and Decker GS-03F-062GA 4 D-10 Workbench Stanley Black and Decker GS-03F-062GA 3 D-11 Height-Adjustable Desk Haworth GS-03F-057DA 2

71 PART I, OFFICE FILES & STORAGE

F-1 Executive Credenza Haworth GS-03F-057DA 2 F-2 Bookshelf Haworth GS-03F-057DA 4 F-3 Credenza Haworth GS-03F-057DA 5 F-4 Tablet Locker Jorgenson Industrial GS-27F-0012W 2 F-5 Lockers Global Industrial GS-03F-076GA 115 F-6 Storage Shelf Nexel GS-03F-076GA 70 F-7 Cell Phone Lockers Jorgenson Industrial GS-27F-0012W 13

Included in const. cost

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 16 of 426

F-8 Mobile Cart Haworth GS-03F-057DA 1 F-9 Student Lockers Global Industrial GS-03F-076GA 48 F-10 File Cabinet Great Openings GS-27F-001CA 2 F-11 Storage System Stanley Black and Decker GS-03F-062GA 7 F-12 Storage System Stanley Black and Decker GS-03F-062GA 4 F-13 Storage System Stanley Black and Decker GS-03F-062GA 151 F-14 Storage System Stanley Black and Decker GS-03F-062GA 6 F-15 Storage System Stanley Black and Decker GS-03F-062GA 3 F-16 Storage System Stanley Black and Decker GS-03F-062GA 1 F-17 Flammable Storage Cabinet Stanley Black and Decker GS-03F-062GA 11 F-18 Storage System Stanley Black and Decker GS-03F-062GA 2 F-19 Storage System Stanley Black and Decker GS-03F-062GA 1 F-20 Storage System Stanley Black and Decker GS-03F-062GA 3 F-21 Storage System Stanley Black and Decker GS-03F-062GA 3 F-22 Storage System Stanley Black and Decker GS-03F-062GA 1 F-23 Storage System Stanley Black and Decker GS-03F-062GA 2 F-24 Mobile Pedestal Haworth GS-03F-057DA 16 F-25 Lockable Cabinet Tennsco GS-03F-076GA 2 F-26 Pallet Racking Lyon LLC GS-27F-035DA 6 F-27 Storage System Stanley Black and Decker GS-03F-062GA 2 F-28 Storage System Stanley Black and Decker GS-03F-062GA 1

71 PART I, OFFICE TABLES

T-1 Conference Table (60 x 240) Haworth GS-03F-057DA 1 T-2 Conference Table (48x192) Haworth GS-03F-057DA 2 T-3 Conference Table (36 x 60) Haworth GS-03F-057DA 22 T-4 Training Table (24 x 72) Haworth GS-03F-057DA 37 T-5 Break Table Haworth GS-03F-057DA 8 T-6 Side Table Haworth GS-03F-057DA 9 T-7 Coffee Table Haworth GS-03F-057DA 6 T-8 Break Table Haworth GS-03F-057DA 9 T-9 Training Table (24 x 60) Haworth GS-03F-057DA 62 T-10 Conference Table (60 x 216) Haworth GS-03F-057DA 1 T-11 Work Station (36 x 60) Stanley Black and Decker GS-03F-062GA 5 T-12 Training Table (24 x 90) Haworth GS-03F-057DA 8 T-13 Conference Table (48 x 240) Haworth GS-03F-057DA 1 T-14 Sewing Table Consew N/A 2

71 PART I, SYSTEMS FURNITURE

S-1 Systems Furniture Haworth GS-03F-057DA 35 S-2 Systems Furniture Haworth GS-03F-057DA 1 S-3 Systems Furniture Haworth GS-03F-057DA 3 S-4 Systems Furniture Haworth GS-03F-057DA 1 S-5 Systems Furniture Haworth GS-03F-057DA 6 S-6 Systems Furniture Haworth GS-03F-057DA 1 S-7 Systems Furniture Haworth GS-03F-057DA 2 S-8 Systems Furniture Haworth GS-03F-057DA 1 S-9 Systems Furniture Haworth GS-03F-057DA 1 S-10 Systems Furniture Haworth GS-03F-057DA 3 S-11 Systems Furniture Haworth GS-03F-057DA 5 S-12 Systems Furniture Haworth GS-03F-057DA 1 S-13 Systems Furniture Haworth GS-03F-057DA 1

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 17 of 426

S-14 Systems Furniture Haworth GS-03F-057DA 1 S-15 Systems Furniture Haworth GS-03F-057DA 1 S-16 Systems Furniture Haworth GS-03F-057DA 1 S-17 Systems Furniture Haworth GS-03F-057DA 1 S-18 Systems Furniture Haworth GS-03F-057DA 49 S-19 Systems Furniture Haworth GS-03F-057DA 3 S-20 Systems Furniture Haworth GS-03F-057DA 1 S-21 Systems Furniture Haworth GS-03F-057DA 1 S-22 Systems Furniture Haworth GS-03F-057DA 1 S-23 Systems Furniture Haworth GS-03F-057DA 1 S-24 Systems Furniture Haworth GS-03F-057DA 1 S-25 Systems Furniture Haworth GS-03F-057DA 9 S-26 Systems Furniture Haworth GS-03F-057DA 2 S-27 Systems Furniture Haworth GS-03F-057DA 1

71 PART I, OFFICE EQUIPMENT

E-1 Refrigerator Frigidaire GS-21F-029DA 5 E-2 Microwave Avanti Products GS-02F-0109R 3 E-3 Ice Maker Manitowoc Ice GS-07F-0352W 2 E-4 Coffee Maker Bunn-O-Matic GS-14F-0017M 4 E-5 Freezer Summit Appliances GS-06F-0046N 1 E-6 Roller Shade Mermet N/A 6 E-7 Roller Shade Mermet N/A 2 E-8 Roller Shade Mermet N/A 8 E-9 Roller Shade Mermet N/A 1 E-10 Roller Shade Mermet N/A 2 E-11 Roller Shade Mermet N/A 2

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 18 of 426

SECTION 7

ACCESSORIES

LOCATION CODES A-1 THROUGH A-10

WASTEBASKETS

MARKER BOARDS

MIRRORS

CLOCKS

ORDER DATA SHEETS FOR

B-21 Formal Training Unit/AMU (FTU)

Am #0005 12 50 00.13 10AT1 Page 19 of 426