I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
KEVIN O. WATSON, PE
DATE: 4/22/16 LIC. NO. 51801
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
CHRISTOPHER CAHILL, PE
DATE: 4/22/16 LIC. NO. 26409
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
GRAHAM EDWARD JOHNSON, PE
DATE: 4/22/16 LIC. NO. 51389
COPYRIGHT © 2016 BURNS & McDONNELL ENGINEERING COMPANY, INC.
US Army Corps of Engineers Omaha District
PROJECT NUMBER:
FOR ADVERTISEMENT
US Army Corps of Engineers Omaha District
THIS PROJECT WAS DESIGNED BY THE OMAHA DISTRICT OF THE US
ARMY CORPS OF ENGINEERS. THE INITIALS OR SIGNATURES AND
REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE
PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS
REQUIRED BY ER 1110-1-8152.
THE FOLLOWING SIGNATURES BELOW INDICATE OFFICIAL APPROVAL OF
ALL DRAWINGS IN THIS SET DATED:
BURNS & MCDONNELL
8201 NORMAN CENTER DR. #300
BLOOMINGTON, MN 55437
952-656-6003
SOLICITATION NUMBER: W9128F-16-B-0007
ELECTRICAL ENGINEERMECHANICAL ENGINEERFIRE PROTECTION ENGINEER
STRUCTURAL ENGINEERARCHITECTCIVIL ENGINEER
QJVF143101
FY15 P-341 CONSTRUCT ADDITION B1134
MINOT AFB, NORTH DAKOTA
APRIL 2016
2/23/16
D E
S
IG
N E
D B
Y
1 432
A
B
C
D
C O
P Y
R
IG
H T
B
U R
N S
M c D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
P N
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
O M
A H
A N
E B
R A
S K
A D
W N
B Y
C
K D
B Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
D A
T E
S U
B M
IT
T
E D
B Y
C
O N
T R
A C
T N
O
F
IL
E N
U M
B E
R
X
S O
L
IC
IT
A
T
IO
N N
O
A F
-2
A S
I N
D
IC
A T
E D
A P
R
IL
W F
-1 -B
-0
S Y
M
D A
T E
A P
P R
D
E S
C R
IP
T
IO
N
B
U R
N S
M c D
O N
N E
L L
N
O R
M A
N C
E N
T E
R D
R
B L O
O M
IN
G
T O
N M
N
-6
-6
/2
/2
:4
:4
A
M
G-001
Q J V
F
F Y
P
-3 C
O N
S T
R U
C T
A D
D
IT
IO
N
B
S H
E E
T I N
D E
X
J .W
IE
D
E R
H O
L T
P .R
Y A
N J .P
IC
K
A M
IN
O
T A
F B
N
O R
T H
D A
K O
T A
/2
/1
M
IA
G
-0
DESIGN FILE DRAWING CODE SHEET NO. DESCRIPTION
MIA8 AF212-220 FA001 FIRE ALARM SYMBOLS, LEGEND AND ABBREVIATIONS
MIA8 AF212-220 FA101 FIRE ALARM AND MASS NOTIFICATION PLAN LAYOUT
MIA8 AF212-220 FA601 FIRE ALARM RISER
MIA8 AF212-220 FA602 FIRE ALARM MATRIX
MIA8 AF212-220 FX001 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS
MIA8 AF212-220 FX101 FIRE SUPPRESSION GROUND FLOOR PLAN
MIA8 AF212-220 P-001 PLUMBING GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
MIA8 AF212-220 PD101 DEMOLITION PLUMBING PLAN
MIA8 AF212-220 P-101 PLUMBING DOMESTIC WATER & GASES PLAN
MIA8 AF212-220 P-110 PLUMBING WASTE & VENT PLAN
MIA8 AF212-220 P-500 PLUMBING DETAILS
MIA8 AF212-220 P-601 PLUMBING SCHEDULES
MIA8 AF212-220 P-701 PLUMBING RISER DIAGRAMS
MIA8 AF212-220 M-001 MECHANICAL GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
MIA8 AF212-220 MD101 DEMOLITION MECHANICAL HVAC PLAN
MIA8 AF212-220 M-101 MECHANICAL HVAC PLAN
MIA8 AF212-220 M-111 MECHANICAL PIPING PLAN
MIA8 AF212-220 M-501 MECHANICAL DETAILS
MIA8 AF212-220 M-502 MECHANICAL DETAILS
MIA8 AF212-220 M-503 MECHANICAL DETAILS
MIA8 AF212-220 M-504 MECHANICAL DETAILS
MIA8 AF212-220 M-601 MECHANICAL SCHEDULES
MIA8 AF212-220 M-701 MECHANICAL CONTOLS
MIA8 AF212-220 M-702 MECHANICAL CONTOLS
MIA8 AF212-220 M-703 MECHANICAL CONTOLS
MIA8 AF212-220 M-704 MECHANICAL CONTOLS
MIA8 AF212-220 M-705 MECHANICAL CONTOLS
MIA8 AF212-220 M-706 MECHANICAL CONTOLS
MIA8 AF212-220 E-001 ELECTRICAL SYMBOLS LEGEND - 1 OF 2
MIA8 AF212-220 E-002 ELECTRICAL SYMBOLS LEGEND - 2 OF 2
MIA8 AF212-220 ED101 DEMOLITION POWER AND COMMUNICATIONS PLAN
MIA8 AF212-220 ED102 DEMOLITION GROUNDING AND LIGHTNING PROTECTION PLAN
MIA8 AF212-220 ED111 DEMOLITION LIGHTING PLAN
MIA8 AF212-220 ED701 DEMOLITION PANELBOARD SCHEDULE
MIA8 AF212-220 E-101 POWER PLAN - AREA A
MIA8 AF212-220 E-102 GROUNDING AND LIGHTNING PROTECTION PLAN
MIA8 AF212-220 E-111 LIGHTING PLAN - AREA A
MIA8 AF212-220 E-121 COMMUNICATIONS PLAN - AREA A
MIA8 AF212-220 E-201 LIGHTNING PROTECTION ELEVATIONS
MIA8 AF212-220 E-501 GROUNDING AND LIGHTNING PROTECTION DETAILS
MIA8 AF212-220 E-502 GROUNDING AND LIGHTNING PROTECTION DETAILS
MIA8 AF212-220 E-503 COMMUNICATION DETAILS
MIA8 AF212-220 E-504 HAZARDOUS CLASSIFICATION DETAILS
MIA8 AF212-220 E-601 ELECTRICAL RISER DIAGRAM
MIA8 AF212-220 E-602 COMMUNICATION RISER DIAGRAM
MIA8 AF212-220 E-701 ELECTRICAL SCHEDULES
MIA8 AF212-220 E-702 ELECTRICAL PANELBOARD SCHEDULES
MIA8 AF212-220 G-000 TITLESHEET
MIA8 AF212-220 G-001 SHEET INDEX
MIA8 AF212-220 LS001 LIFE SAFETY NARRATIVE AND BUILDING CODE ANALYSIS
MIA8 AF212-220 LS101 LIFE SAFETY FLOOR PLAN
MIA8 AF212-220 C-001 VICINITY MAP AND LOCATION PLAN
MIA8 AF212-220 C-002 GENERAL CIVIL NOTES
MIA8 AF212-220 V-101 EXISTING CONDITIONS PLAN
MIA8 AF212-220 CD101 DEMOLITION PLAN
MIA8 AF212-220 CS101 SITE PLAN
MIA8 AF212-220 CG101 GRADING PLAN
MIA8 AF212-220 CP101 PAVEMENT JOINTING AND ELEVATION PLAN
MIA8 AF212-220 CU101 UTILITY PLAN
MIA8 AF212-220 C-500 PAVEMENT DETAILS (SHEET 1 OF 2)
MIA8 AF212-220 C-501 PAVEMENT DETAILS (SHEET 2 OF 2)
MIA8 AF212-220 C-502 SITE AND UTILITY DETAILS
MIA8 AF212-220 S-001 GENERAL NOTES - SHEET 1
MIA8 AF212-220 S-002 GENERAL NOTES - SHEET 2
MIA8 AF212-220 S-003 LEGEND & ABBREVIATIONS
MIA8 AF212-220 S-004 STATEMENT OF SPECIAL INSPECTIONS
MIA8 AF212-220 S-005 STATEMENT OF SPECIAL INSPECTIONS
MIA8 AF212-220 S-101 SLAB AND FOUNDATION PLAN
MIA8 AF212-220 S-102 ROOF FRAMING PLAN
MIA8 AF212-220 S-201 ELEVATIONS
MIA8 AF212-220 S-202 ELEVATIONS
MIA8 AF212-220 S-301 STANDARD CONCRETE DETAILS
MIA8 AF212-220 S-302 SLAB AND FOUNDATION DETAILS
MIA8 AF212-220 S-303 CONCRETE DETAILS
MIA8 AF212-220 S-304 STANDARD ROOF DECK & JOIST DETAILS
MIA8 AF212-220 S-401 ROOF FRAMING DETAILS
MIA8 AF212-220 S-402 ROOF FRAMING DETAILS
MIA8 AF212-220 AG000 ARCHITECTURAL LEGEND, ABBREVIATIONS AND GENERAL NOTES
MIA8 AF212-220 AD011 DEMOLITION PLAN - OVERALL
MIA8 AF212-220 AD101 DEMOLITION PLAN - AREA A
MIA8 AF212-220 A-011 FLOOR PLAN - OVERALL
MIA8 AF212-220 A-101 FLOOR PLAN - AREA A
MIA8 AF212-220 A-103 ROOF PLAN - AREA A
MIA8 AF212-220 A-151 REFLECTED CEILING PLAN - AREA A
MIA8 AF212-220 A-201 ENLARGED ELEVATIONS
MIA8 AF212-220 A-301 BUILDING SECTIONS
MIA8 AF212-220 A-331 WALL SECTIONS
MIA8 AF212-220 A-401 DETAILS
MIA8 AF212-220 A-501 PARTITION TYPES
MIA8 AF212-220 A-521 PENETRATION DETAILS
MIA8 AF212-220 A-522 PENETRATION DETAILS
MIA8 AF212-220 A-601 SCHEDULES
MIA8 AF212-220 A-602 DOOR DETAILS
MIA8 AF212-220 A-603 DOOR DETAILS
MIA8 AF212-220 A-701 SIGNAGE PLAN - AREA A
MIA8 AF212-220 A-731 INTERIOR ELEVATIONS AND CASEWORK DETAILS
FA001
FA101
FA601
FA602
FX001
FX101
P-001
PD101
P-101
P-110
P-500
P-601
P-701
M-001
MD101
M-101
M-111
M-501
M-502
M-503
M-504
M-601
M-701
M-702
M-703
M-704
M-705
M-706
E-001
E-002
ED101
ED102
ED111
ED701
E-101
E-102
E-111
E-121
E-201
E-501
E-502
E-503
E-504
E-601
E-602
E-701
E-702
G-000
G-001
LS001
LS101
C-001
C-002
V-101
CD101
CS101
CG101
CP101
CU101
C-500
C-501
C-502
S-001
S-002
S-003
S-004
S-005
S-101
S-102
S-201
S-202
S-301
S-302
S-303
S-304
S-401
S-402
AG000
AD011
AD101
A-011
A-101
A-103
A-151
A-201
A-301
A-331
A-401
A-501
A-521
A-522
A-601
A-602
A-603
A-701
A-731
DESIGN FILE DRAWING CODE SHEET NO. DESCRIPTION
S Y
M
D A
T E
D E
S C
R
IP
T
IO
N A
P P
R
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
PL
O T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X
SO
LI
C
IT
AT
IO
N N
O
AF
2-
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
BU
R N
S
M C
D O
N N
EL
L
N
O R
M
AN
C
EN
TE
R
D R
BL
O O
M
IN
G
TO
N , M
N
2-
6-
4/
/2
1:
:5
PM
LS001
Q
JV
F1
FY
P-
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
LI
FE
S
AF
ET
Y
N
AR
R
AT
IV
E
AN
D
B U
IL
D
IN
G
C O
D E
AN
AL
YS
IS
J.
D
EW
C . C
AH
IL
L H
AN
KI
N S
M
IN
O T
AF
B , N O
R T H
D
AK
O
TA
4/
/1
M
IA
8L S0
9. PASSIVE FIRE PROTECTION PENETRATION PROTECTION
COMPONENT DOORS DUCT PENETRATIONS OTHER PENETRATIONS CODE SECTION
1 HOUR FIRE BARRIER 3/4 HOUR NOT REQUIRED 1 HOUR, INCLUDING
TRANSFER OPENINGS NFPA 90A 5.3.1.1
2 HOUR FIRE BARRIER 1-1/2 HOUR 1-1/2 HOUR DAMPER 2 HOUR, INCLUDING
TRASNFER OPENINGS NFPA 90A 5.3.1.1
6. TYPE OF CONSTRUCTION (IBC 602)
BUILDING ELEMENT
TYPE OF
CONSTRUCTION
FIRE RESISTANCE
RATING
PRIMARY STRUCTURAL FRAME IIB 0 HR **
BEARING EXTERIOR WALL IIB 0 HR **
BEARING INTERIOR WALL IIB 0 HR **
NON-BEARING EXTERIOR WALL IIB
NON-BEARING INTERIOR WALL IIB 0 HR **
FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS IIB 0 HR **
ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS IIB
1. CLASSIFICATION OF OCCUPANCY
BUILDING IDENTIFICATION OCCUPANCY CLASSIFICATION (IBC 2012) IBC
OFFICE AREA BUSINESS GROUP B 304.1
MAINTENANCE/INDUSTRIAL AREA INDUSTRIAL F-1 306.2
FUEL ROOM HIGH HAZARD H-3 307.5
2. ACCESSORY OCCUPANCY (IBC 508.2)
FLOOR FLOOR AREA
(SF) ACCESSORY
ACCESSORY AREA
(SF)
PERCENTAGE OF AREA
(SUM < 10%)
IBC AREA LIMITATION
(SF)
LEVEL 1 35,434 H-3 1363 3% 3,497
5. MODIFIED ALLOWABLE HEIGHT (IBC 504.2)
OCCUPANCY
*RESTRICTING ALLOWABLE
HEIGHT (FT / STORY)
SPRINKLER INCREASE
(FT / STORY)
MODIFIED ALLOWABLE
HEIGHT (FT / STORY)
F-1 55 / 2 20 / 1 75 / 3 B 55 / 3 20 / 1 75 / 4
3. OCCUPANCY SEPARATION
FLOOR / OCCUPANCY SEPARATION FLOOR / OCCUPANCY
SEPARATION
RATING IBC
LEVEL 1, H-3 SEPERATED LEVEL 1, F-1 1 HR BARRIER 508.4.4
LEVEL 1, H-3 SEPERATED LEVEL 1, B 1 HR BARRIER 508.4.4
LEVEL 1, F-1 SEPERATED LEVEL 1, B 0 HR BARRIER 508.4.4
7. BUILDING SEPARATION (IBC TABLE 602)
BUILDING TYPES FIRE SUPPRESSION DISTANCE (FT) FIRE RESISTIVE RATING FO EXTERIOR WALL
B, F-1 >10 0 HOUR (ACTUAL SEPARATION 90 FEET)
4. MODIFIED ALLOWABLE AREA (IBC 506)
OCCUPANCY
*ALLOWABLE AREA
(SF)
FRONTAGE
INCREASE (SF)
SPRINKLER
INCREASE (SF)
MODIFIED ALLOWABLE
AREA (SF)
*H-3 14,000 NOT PERMITED NOT PERMITED 14,000
B 23,000 17,250 46,000 86,250 F-1 15,500 11,625 31,000 53,125
11. OCCUPANT LOAD CALCULATIONS (NFPA 101 TABLE 7.3.1.2)
FLOOR AREA FUNCTION OF SPACE AREA (SF)
OCCUPANT
LOAD FACTOR
(SF/PERSON) OCCUPANTS
LEVEL 1 BREAK ROOM ASSEMBLY AREAS 626 15 42
LEVEL 1 OFFICES, BATHROOMS BUSINESS AREAS 7102 100 72
LEVLE 1 INDUSTRIAL AREA INDUSTRIAL AREAS 27,705 100 278
35434 TOTAL BUILDING 392
12. OCCUPANT LOAD SUMMARY AND MINIMUM EXITS FROM FLOOR (NFPA 101)
FLOOR OCCUPANTS REQUIRED EXITS (NFPA 101) REQUIRED EXIT SEPARATION (NFPA 101)
LEVEL 1 392 *2 (7.4.1.2) 1/3 DIAGONAL
13. MINIMUM EXITS OR EXIT ACCESSES FROM A SPACE OR AREA (NFPA 101 )
OCCUPANCY
OCCUPANT LOAD PERMITTING
ONE EXIT
OCCUPANT LOAD REQUIRING
TWO EXITS
NFPA 101
SECTION
BUSINESS LESS THAN COMMON PATH GREATER THAN COMMON PATH 38.2.4
INDUSTRIAL LESS THAN COMMON PATH GREATER THAN COMMON PATH 40.2.4
HIGH HAZARD EXCEPTIONS 1-3 (7.11.4) ALL CONDITIONS 7.11.4
14. COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS (NFPA 101, TABLE 7.6)
OCCUPANCY COMMON PATH LIMIT (FT) DEAD END LIMIT (FT)
TRAVEL DISTANCE LIMIT
(FT)
INDUSTRIAL 100 50 400
BUSINESS 100 50 300
HIGH HAZARD 0 0 75
15. MINIMUM EGRESS WIDTHS (NFPA 101, 7.2 & 7.3)
COMPONENT REQUIREMENT WIDTH (IN) NFPA 101
CORRIDOR SERVING 50 OR MORE OCCUPANTS PER COMPONENT 44 7.3.4.1
DOORS IN EGRESS ACCESS PER COMPONENT 32 7.2.1.2.3.2
LEVEL COMPONENTS PER PERSON 0.2 7.2.2.2.1.2
8. PASSIVE FIRE PROTECTION
COMPONENT REQUIRED RATING CODE SECTION
CORRIDOR 0 HOUR NFPA 101 38.3.6 AND 40.3.6
10. MINIMUM INTERIOR FINISH RATINGS (NFPA 101 TABLE A.10.2.2)
OCCUPANCY
EXIT ENCLOSURE AND EXIT
PASSAGEWAYS CORRIDORS OTHER SPACES
BUSINESS CLASS B CLASS C CLASS C
INDUSTRIAL CLASS C CLASS C CLASS C
HIGH HAZARD CLASS B CLASS B CLASS C
17. FIRE SUPPRESSION REQUIREMENTS (UFC 3-600-01)
SPRINKLERS (UFC 3-300-01 4-2.2) STANDPIPE (UFC 3-600-01 4-2.3.8 )
FIRE EXTINGUISHERS
(UFC 3-600-01 4.9 )
SPRINKLERS PROVIDED
THROUGHOUT THE BUILDING
NOT REQUIRED FIRE EXTINGUISHERS PROVIDED
THROUGHOUT THE BUILDING
18. FIRE ALARM REQUIREMENTS (UFC 3-600-01)
AUTOMATIC INITIATION OCCUPANT INITIATION MANUAL INITIATION
SPRINKLER FLOW SWITCHES VOICE MESSAGING MANUAL FIRE ALARM PULL
STATIONS AT EXITS
SPOT SMOKE DETECTORS AT ALARM PANELS WHITE FIRE ALARM
DUCT SMOKE DETECTORS
19. FIRE EXTINGUISHER DISTRIBUTION (NFPA 10 TABLE 6.2.1.1)
OCCUPANCY
PRIMARY CLASSIFICATION
OF FIRE AND HAZARD
MINIMUM
RATING
MAXIMUM TRAVEL
DISTANCE (FT)
MINIMUM FLOOR
AREA PER A (SF)
BUSINESS/INDUSTRIAL CLASS A:C - ORDINARY 2-A 75 1,500
HIGH HAZARD CLASS B - EXTRA HAZARD 40-B 30 N/A
21. SMOKE MANAGEMENT SYSTEMS
SMOKE CONTROL SYSTEM
(NFPA 101)
SMOKE AND HEAT VENTS
(NFPA 101) PASSIVE SMOKE MANAGEMENT
NOT REQUIRED NOT REQUIRED NOT REQUIRED
EXCEPT AS REQUIRED FOR OCCUPANCY SEPARATION, INCIDENTAL USE, AND OTHER PASSIVE FIRE
PROTECTION, SEE SECTION 9.7.3.
ACCESSORY H SHALL NOT EXCEED THE TABULAR VALUES WITHOUT ANY INCREASES.*
DUE TO LAYOUT OF THE FACILITY MORE THAN THE ABOVE MINIMUM EXITS ARE REQUIRED.*
16. EMERGENCY LIGHTING AND EXITING
OCCUPANCY EMERGENCY LIGHTING EXIT SIGNAGE
INDUSTRIAL REQUIRED (NFPA 101 40.2.9.1) REQUIRED (NFPA 101 40.2.9)
BUSINESS REQUIRED (NFPA 101 38.2.9.1) REQUIRED (NFPA 101 38.2.9)
HIGH HAZARD REQUIRED (NFPA 101 40.2.9.1) REQUIRED (NFPA 101 40.2.9)
20. FIRE HYDRANT DISTRIBUTION
DISTANCE TO BUILDING (FT) DISTANCE TO FDC (FT) FIRE TRUCK ACCESS (FT)
300 150 33
0 HR
0 HR
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
PR
CP
CP
CP
2 HOUR FIRE BARRIER
FIRE AND SMOKE RESISTIVE CONSTRUCTION
REQUIRED WIDTH
EXIT CAPACITY
OCCUPANTS SERVED
COMMON PATH OF
TRAVEL
TRAVEL DISTANCE
EGRESS PATH
COMMON PATH
TERMINATION POINT
PORTABLE FIRE EXTINGUISHERS
EXIT DOOR
PROVIDED WIDTH
OCCUPANT LOAD LEGEND
INDUSTRIAL
32" 36"
FE-SR
DOOR EGRESS TAG
EGRESS PATH
BUSINESS AREAS
1 PERSON / 100 SF GROSS
1 PERSON / 100 SF GROSS
50'CP:25'
PORTABLE FIRE EXTINGUISHER
4A-20B:C
GENERAL NOTES:
1. REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL
INFORMATION REGARDING SYMBOLS AND
ABBREVIATIONS.
2. REFER TO LS001 FOR LIFE SAFETY NARRATIVE AND
BUILDING CODE ANALYSIS.
3. REFER TO THE ELECTRICAL LIGHTING PLANS FOR
LOCATION OF EXIT SIGNS AND EMERGENCY LIGHTING.
4. REFER TO THE FIRE SUPPRESSION AND ALARM PLANS
FOR LOCATION OF FIRE PROTECTION DEVICES.
5. FINAL LOCATIONS OF FIRE EXTINGUISHERS AND HOSE
REELS SHALL BE APPROVED BY THE AHJ PRIOR TO
INSTALLATION.
KEYED NOTES:
EXISTING CONSTRUCTION TYPE, RATING, AND FIRE
EXTINGUISHER LOCATIONS TO REMAIN UNCHANGED
IN EXISTING BUILDING.
RESTRICTED AREA SHALL REMAIN UNCHANGED AND
UNAFFECTED BY THE ADDITION. FOR SECURITY
PURPOSES, EGRESS DOORS WITHIN THIS AREA ARE
NOT SHOWN.
ASSEMBLY AREAS 1 PERSON / 15 SF GROSS
F
E
D
A
C
B
A
B
C
D
E
F
2 3 5 61
A
B
C
D
E
F
2 3 4 5 6
X117
X116
X115
X114
X113
X102
X101 X103
X112
X104
X111 X110
X105 X106
X108X109
106 107 108 109
110X122X121X118
SECURE AREA (RESTRICTED ACCESS)
32" 34"
32" 34"
32" 34"
32" 34"
32" 34"
32" 34"
32"
92" 107'CP:27'
70'CP:0'
32" 34"
32" 34"
FE-SR
FE-SR
FE-SR FE-SR
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
P
LO
T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X2
SO
LI
C
IT
AT
IO
N N
O
AF
2-
A
KEYPLAN
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
B
C
BU
R
N S
M
C D
O N
N
EL
L
N O
R M
AN
C
EN
TE
R D
R
BL
O
O M
IN
G
TO
N
, M N
2-
6-
4/
/2
1:
:5
PM
LS101
Q
JV
F1
FY
P-
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
LI
FE
S
AF
ET
Y
FL
O
O R
P
LA
N
J.
D
EW
C . C
AH
IL
L H
AN
KI
N S
M
IN
O T
AF
B , N O
R T H
D
AK
O
TA
4/
/1
M
IA
8L S1
LS101 N
LIFE SAFETY FLOOR PLAN
SCALE IN FEET
0 8' 16' 32'
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
GENERAL NOTES:
1. GENERAL:
A. THESE NOTES, AND OTHER DRAWING NOTES CONTAINED WITHIN, ARE PROVIDED
TO MEET SPECIFIC REQUIREMENTS AND TO SUPPLEMENT THE CONTRACT
SPECIFICATIONS. THESE NOTES NEITHER REPLACE NOR OVERRIDE THE
PROVISIONS AND REQUIREMENTS OF THE CONTRACT SPECIFICATIONS.
B. CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH WORK SHOWN
ON ALL OTHER DRAWINGS.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION AND
REPORT ANY DISCREPANCIES FROM THE CONTRACT DRAWINGS
TO THE CONTRACTING OFFICER PRIOR TO COMMENCING
WITH WORK. SCALING OF WORKING DIMENSIONS FROM THE STRUCTURAL
DRAWINGS IS PROHIBITED.
D. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS
OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, SHORING AND TEMPORARY
BRACING. CONTRACTOR SHALL UNDERTAKE ALL NECESSARY MEASURES TO ENSURE
SAFETY OF ALL PERSONS AND STRUCTURES AT THE SITE AND ADJACENT TO THE SITE.
VISITS TO THE SITE BY THE CONTRACTING OFFICER'S REPRESENATIVE SHALL NOT RELIEVE THE
CONTRACTOR OF SUCH RESPONSIBILITY.
E. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE CONTRACT
DRAWINGS OR SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME
CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR, WITH
THE APPROVAL OF THE CONTRACTING OFFICER'S REPRESENTATIVE. WHERE SECTIONS VARY,
CONTRACTOR SHALL PROVIDE FOR SMOOTH TRANSITIONS BETWEEN THEM, UNLESS
NOTED OTHERWISE.
F. ALL PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS'
WRITTEN INSTRUCTIONS AND RECOMMENDATIONS, UNLESS NOTED OTHERWISE.
G. ELEVATION 100'-0" CORRESPONDS TO MSL ELEVATION 1635.0 FT, UNO.
2. DESIGN STANDARDS
A. PRINCIPAL CODE OF RECORD: UFC 1-200-01, UNIFIED FACILITIES CRITERIA (UFC),
DESIGN: GENERAL BUILDING REQUIREMENTS, 1 JULY 2013.
B. INTERNATIONAL BUILDING CODE 2012.
C. ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2010.
D. ACI 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2011.
E. ACI 530/ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES, 2011.
F. AISC STEEL CONSTRUCTION MANUAL, 14th EDITION, 2010.
G. AISI COLD-FORMED STEEL DESIGN MANUAL, 2010.
H. AWS D1.1/1.1M. 2010
I. OSHA 29 CFR 1926 SUBPART R - STEEL ERECTION.
D. EQUIPMENT LOADS
1. AS INDICATED FOR EQUIPMENT WEIGHING IN EXCESS OF 250 LBS. FRAMING AND
FOUNDATIONS ARE DESIGNED FOR EQUIPMENT WHICH SATISFIES THE
CONTRACT SPECIFICATIONS.
2. IF EQUIPMENT FURNISHED IS HEAVIER THAN THE WEIGHTS INDICATED, OR
REQUIRES STRUCTURAL CHANGES FOR ANY OTHER REASON, CONTRACTOR
SHALL PROVIDE ENGINEERING DESIGN CALCULATIONS AND ADDITIONAL
STRUCTURAL WORK NECESSARY TO SUPPORT ALL LOADS IN ACCORDANCE
WITH THE DESIGN STANDARDS SPECIFIED ABOVE, AT NO ADDITIONAL COST TO
THE OWNER AND WITH NO INCREASE IN CONTRACT TIME.
E. SNOW LOAD PER UFC 3-301-01
1. GROUND SNOW LOAD: 40 PSF.
2. FLAT-ROOF SNOW LOAD: 40 PSF.
3. EXPOSURE FACTOR: 0.9.
4. IMPORTANCE FACTOR: 1.0.
5. THERMAL FACTOR: 1.0.
F. WIND LOAD PER UFC 3-301-01
1. BASIC WIND SPEED: 115 MPH 3-SECOND GUST.
2. IMPORTANCE FACTOR: 1.0.
3. EXPOSURE CATEGORY: C.
4. BUILDING CONDITION: ENCLOSED.
5. TOPOGRAPHIC FACTOR: 1.0.
6. WALL COMPONENTS AND CLADDING, SHALL BE DESIGNED FOR THE FOLLOWING
UNFACTORED SERVICE WIND LOADS, UNLESS NOTED OTHERWISE:
a. WITHIN 8'-0" OF CORNERS: 13.8 PSF INWARD, 16.4 PSF OUTWARD
b. GREATER THAN 8'-0" FROM CORNERS: 13.8 PSF INWARD, 15.2 PSF OUTWARD
c. AT PARAPETS WITHIN 8'-0" FROM CORNERS: 63.6 PSF INWARD, 92.6 PSF OUTWARD
d. AT PARAPETS GREATER THAN 8'-0" FROM CORNERS: 44.8 PSF INWARD,
74.0 PSF OUTWARD
7. ROOF COMPONENTS AND CLADDING SHALL BE DESIGNED FOR THE FOLLOWING
UNFACTORED SERVICE WIND LOADS, UNLESS NOTED OTHERWISE:
a. WITHIN 8'-0" OF CORNERS: 9.6 PSF INWARD, 46.3 PSF OUTWARD
b. WITHIN 8'-0" OF EDGES: 9.6 PSF INWARD, 30.8 PSF OUTWARD
c. GREATER THAN 8'-0" FROM EDGES: 9.6 PSF INWARD, 18.4 PSF OUTWARD
G. SEISMIC LOAD PER UFC 3-301-01
1. MAXIMUM CONSIDERED EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS
Ss = 0.05, S1 = 0.02.
2. DESIGN EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS
Sds = 0.08, Sd1 = 0.04.
3. IMPORTANCE FACTOR: 1.0.
4. SITE CLASS: D.
5. SEISMIC DESIGN CATEGORY: A.
6. BASIC SEISMIC FORCE RESISTING SYSTEM: ORDINARY REINFORCED CONCRETE SHEAR WALLS.
7. RESPONSE MODIFICATION COEFFICIENT: R = 4.
8. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE.
H. ICE LOAD PER UFC 3-301-01 (FOR ESTIMATING LIGHTNING PROTECTION POLE REACTIONS)
1. 0.50 INCH EQUIVALENT RADIAL ICE THICKNESS DUE TO FREEZING RAIN WITH CONCURRENT
60 MPH 3-SECOND GUST WIND SPEED FOR 50-YEAR MEAN RECURRENCE INTERVAL.
2. IMPORTANCE FACTOR: 1.25
3. LIGHTNING PROTECTION POLE HEIGHTS
a. 76 FEET
b. 40 FEET
7. GEOTECHNICAL INFORMATION
A. SOURCE: REPORT OF GEOTECHNICAL EXPLORATION, PREPARED BY MATERIAL TESTING SERVICES, LLC.
B. SITE PREPARATION
1. EXCAVATION, FILL, AND BACKFILL SHALL BE IN ACCORDANCE WITH THE
CONTRACT DRAWINGS AND SPECIFICATIONS, DIVISION 310000.
2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S
REPRESENTATIVE WHEN LOOSE OR SOFT SOILS ARE EXPOSED WHERE
SLABS, MATS, OR FOOTINGS ARE TO BE PLACED SO THAT A DETERMINATION
MAY BE MADE REGARDING IMPROVEMENT OF THIS POTENTIALLY
UNDESIRABLE CONDITION.
C. SOIL CHARACTERISTICS
1. WATER TABLE DEPTH: 6 FT.
D. LATERAL EARTH PRESSURE
1. PASSIVE CONDITION, Kp: 375 PCF, EQUIVALENT FLUID (ULTIMATE).
E. SLAB AND FOOTING DESIGN PARAMETERS
1. MODULUS OF SUBGRADE REACTION: 150 PCI.
2. ALLOWABLE BEARING CAPACITIES
a. GRAVITY LOADS: 2000 PSF.
3. FROST DEPTH: 72"
4. CONCRETE-SOIL COEFFICIENT OF FRICTION: 0.35 (ULTIMATE).
5. MINIMUM STABILITY FACTORS OF SAFETY
a. OVERTURNING: 1.5.
b. UPLIFT: 1.5.
c. SLIDING: 1.5.
F. LIGHTNING PROTECTION POLE FOUNDATION
1. ASSUMED LATERAL SOIL BEARING PRESSURE: 100 PSF/FT
PER IBC 2012 TABLE 1806.2
4. FORMWORK
a. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, ENGINEERING, STRUCTURAL ADEQUACY, AND CONSTRUCTION OF ALL CONCRETE
FORMWORK IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS.
b. COORDINATE ALL CONCRETE WORK WITH THE PLACEMENT OF PIPING, INSERTS, FLOOR DRAINS, AND OTHER EMBEDDED ITEMS INDICATED ON
THE CONTRACT DRAWINGS OR IN THE CONTRACT SPECIFICATIONS.
c. ALL NEW OR EXISTING PIPING OR UTILITIES PASSING THROUGH NEW
CONCRETE SHALL BE SLEEVED 1/2" CLEAR ALL AROUND, UNLESS NOTED
OTHERWISE. SEE OTHER DISCIPLINE DRAWINGS FOR SLEEVE DETAILS.
CONTRACTOR SHALL PROVIDE MEASURES TO ENSURE THAT SLEEVES
REMAIN FREE OF DEBRIS AND WATER DURING CONSTRUCTION.
d. PROVIDE 3/4" CHAMFER STRIPS ON ALL EDGES OF EXPOSED CONCRETE, UNLESS NOTED OTHERWISE.
e. WITH THE EXPLICIT PRIOR APPROVAL IN WRITING OF THE CONTRACTING
OFFICER, COLUMN AND WALL FOOTINGS MAY BE EARTH-FORMED USING
UNDISTURBED NATIVE SOIL. PROVIDE A MINIMUM EXCAVATION WIDTH 4"
GREATER THAN INDICATED, AND A DEPTH 2" GREATER THAN INDICATED.
5. REINFORCING STEEL
a. BARS: ASTM A615 GRADE 60, UNO.
b. WELDED WIRE FABRIC: ASTM A185.
c. ALL CONCRETE SHALL BE REINFORCED UNLESS SPECIFICALLY MARKED "NOT
REINFORCED" OR "UNREINFORCED".
d. CONTRACTOR SHALL DETAIL AND PLACE ALL REINFORCEMENT IN
ACCORDANCE WITH ACI SP-66, ACI 301, ACI 318, AND CRSI MANUAL OF
STANDARD PRACTICE.
e. MINIMUM CONCRETE CLEAR COVER OVER REINFORCEMENT SHALL BE AS
FOLLOWS, UNLESS NOTED OTHERWISE:
(1) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3".
(2) CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #11 BARS -
2"; #5 AND SMALLER BARS, WELDED WIRE FABRIC - 1 1/2".
(3) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE
GROUND: SLABS AND WALLS - 3/4"; BEAMS AND COLUMNS, PRIMARY
REINFORCEMENT, TIES, STIRRUPS, SPIRALS - 1 1/2".
f. EMBEDMENT AND LAP SPLICE LENGTHS FOR ALL REINFORCING STEEL BARS
SHALL CONFORM TO THE FOLLOWING PROVISIONS, UNLESS NOTED
OTHERWISE.
(1) MINIMUM STRAIGHT EMBEDMENT LENGTHS:
#3 - 12" #6 - 18" #9 - 36" #4 - 12" #7 - 25" #10 - 44" #5 - 15" #8 - 29" #11 - 53"
(2) MINIMUM LAP SPLICE LENGTHS:
#3 - 12" #6 - 23" #9 - 46" #4 - 15" #7 - 33" #10 - 57" #5 - 19" #8 - 37" #11 - 68"
(3) MINIMUM HOOK EMBEDMENT LENGTHS:
#3 - 8" #6 - 15" #9 - 22" #4 - 10" #7 - 17" #10 - 25" #5 - 12" #8 - 19" #11 - 27"
(4) HORIZONTAL BARS HAVING MORE THAN 12" OF CONCRETE PLACED
BELOW THEM SHALL BE CONSIDERED TOP REINFORCEMENT AND SHALL
HAVE MINIMUM STRAIGHT EMBEDMENT AND LAP SPLICE LENGTHS
INCREASED BY NOT LESS THAN 30% OVER THOSE GIVEN ABOVE.
(5) HOOK EMBEDMENT IS THE MINIMUM STRAIGHT LINE DISTANCE FROM THE
CRITICAL SECTION OF THE BAR TO THE FARTHEST EDGE OF THE HOOK.
(6) EPOXY GROUT: CONFORM TO ASTM C881, TYPE IV, GRADE 3, EXCEPT GEL
TIMES. PROVIDE MINIMUM EMBEDMENT LENGTH REQUIRED TO DEVELOP
ULTIMATE STRENGTH OF BAR.
g. PROVIDE ADDITIONAL REINFORCEMENT AT ALL OPENINGS AND CORNER BARS
AT ALL INTERSECTING GRADE BEAMS, WALLS, AND CURBS IN ACCORDANCE
WITH THE STANDARD DETAILS ON S-301, UNLESS NOTED
OTHERWISE.
6. JOINTS
a. LOCATE ALL CONSTRUCTION, CONTRACTION, ISOLATION, EXPANSION, AND
OTHER JOINTS AS INDICATED OR SPECIFIED, OR OTHERWISE APPROVED BY
THE CONTRACTING OFFICER.
b. SURFACES OF ALL HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS SHALL
BE CLEANED OF LAITANCE AND SHALL EXPOSE CLEAN COARSE AGGREGATE
SOLIDLY EMBEDDED IN MORTAR MIX. JUST PRIOR TO DEPOSITING CONCRETE,
SURFACE OF CONSTRUCTION JOINT SHALL BE THOROUGHLY CLEANED AND
WETTED.
c. THESE PROVISIONS SHALL ALSO APPLY WHEN NEW CONCRETE IS PLACED
AGAINST EXISTING CONCRETE. IN ADDITION, EXISTING CONCRETE SURFACE
SHALL BE ADEQUATELY PREPARED BY APPLICATION OF A BONDING AGENT.
3. SPECIAL INSPECTIONS: SEE S-004 AND S-005 FOR STATEMENT OF SPECIAL INSPECTIONS.
A. THIS "STATEMENT OF SPECIAL INSPECTIONS" HAS BEEN PREPARED IN
ACCORDANCE WITH IBC 2012, SECTION 1704.
B. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED
THIRD-PARTY QUALITY ASSURANCE AGENCIES TO PROVIDE SPECIAL INSPECTIONS
DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
C. IN ACCORDANCE WITH IBC SECTION 1704.4, CONTRACTOR RESPONSIBLE FOR THE
CONSTRUCTION OF THE MAIN WIND OR SEISMIC-FORCE-RESISTING SYSTEM SHALL
SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE CONTRACTING
OFFICER'S REPRESENTATIVE PRIOR TO COMMENCEMENT OF WORK ON THE
SYSTEM.
D. CONTRACTOR SHALL RETAIN THE SERVICES OF A SPECIAL INSPECTOR OF RECORD
(SIOR) IN ACCORDANCE WITH UFC 3-301-01 SECTION 2-2.3.3 1704.6. SIOR SHALL BE A
LICENSED PROFESSIONAL ENGINEER IN A STATE ACCEPTABLE TO THE CONTRACTING
OFFICER'S REPRESENATIVE, AND SHALL SUBMIT QUALIFICATIONS ACCEPTABLE TO THE
CONTRACTING OFFICER'S REPRESENATIVE.
E. EACH SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL
DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE CONTRACTING
OFFICER'S REPRESENTATIVE, FOR INSPECTION OF THE PARTICULAR TYPE OF
CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.
F. SPECIAL INSPECTION AGENCY SHALL SUBMIT INSPECTION REPORTS DURING
CONSTRUCTION FOR VERIFICATION, INCLUDING FINAL REPORTS IN ACCORDANCE
WITH IBC 2012, SECTION 1704.1.2.
G. SPECIAL INSPECTOR SHALL USE THE LATEST ISSUE OF THE STRUCTURAL
DRAWINGS FOR ALL INSPECTIONS. SHOP FABRICATION DRAWINGS SHALL NOT BE
USED FOR SUCH PURPOSES.
H. THE TABLES SHOWN ON S-004 IDENTIFY THE MATERIALS, SYSTEMS, AND COMPONENTS
FOR WHICH SPECIAL INSPECTION IS REQUIRED. "X" INDICATES THE REQUIRED
FREQUENCY OF INSPECTION AS DEFINED BY THE IBC 2012, SECTION 1702.
4. TESTING REQUIREMENTS:
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED
THIRD-PARTY TESTING AGENCIES TO PROVIDE STRUCTURAL TESTING DURING
CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
B. TESTING AGENCY SHALL SUBMIT TEST RESULTS DURING CONSTRUCTION FOR
VERIFICATION INCLUDING A FINAL REPORT IN ACCORDANCE WITH IBC 2012,
SECTION 1704.2.4.
C. TABLES ON S-004 AND S-005 IDENTIFY THE STRUCTURAL TESTS REQUIRED FOR THIS
PROJECT.
5. STRUCTURAL OBSERVATIONS:
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED
THIRD-PARTY REGISTERED DESIGN PROFESSIONALS TO PROVIDE STRUCTURAL
OBSERVATIONS DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012,
SECTION 1704.5.
B. EACH STRUCTURAL OBSERVER SHALL SUBMIT WRITTEN STATEMENTS IDENTIFYING
FREQUENCY AND EXTENT OF STRUCTURAL OBSERVATIONS AND ANY REPORTED
DEFICIENCIES WHICH HAVE NOT BEEN RESOLVED IN ACCORDANCE WITH IBC 2012,
SECTION 1704.5.
6. DESIGN LOADS
A. OCCUPANCY CLASSIFICATION : CATEGORY II PER UFC 3-301-01.
B. LIVE LOADS PER UFC 3-301-01
1. FLOOR LIVE LOAD: 100 PSF OR A CONCENTRATED LOAD OF 2,000 POUNDS
UNIFORMLY DISTRIBUTED OVER AN AREA 2.5 FT SQUARE.
2. ROOF LIVE LOAD: 20 PSF.
3. FLOOR AND ROOF LIVE LOAD REDUCTION IS NOT PERMITTED PER UFC 3-301-01.
4. MONORAIL: 3 TON
C. COLLATERAL LOADS: 12 PSF
8. MATERIALS: SEE THE CONTRACT SPECIFICATIONS FOR COMPLETE REQUIREMENTS
AND COMPLY WITH ALL APPLICABLE OSHA REGULATIONS
A. REINFORCED CONCRETE: SECTIONS 031113.0010, 031500.0010, 032000.0010, 033000.0010, 033500.0010, 033900.0010.
1. REINFORCED CONCRETE SHALL BE PREPARED AND PLACED IN
ACCORDANCE WITH ACI MANUAL OF CONCRETE PRACTICE.
2. CONCRETE
a. UNLESS NOTED OTHERWISE: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 4500 PSI, NORMAL WEIGHT.
b. INTERIOR SLABS ON GRADE SHALL NOT HAVE AIR ENTRAINMENT.
c. SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT.
d. PROVIDE #4 X 3'-0" DIAGONAL BAR AT ALL REENTRANT CORNERS (TYPICAL).
3. SLAB-ON-GRADE SHALL BE PLACED ON 10 MIL VAPOR BARRIER ON 6" SELECT
GRANULAR FILL PER SPEC SECTION 310000.
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
PL
O T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X
SO
LI
C
IT
AT
IO
N N
O
AF
2-
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
BU
R N
S
M cD
O N
N
EL
L
N O
R M
AN
C
EN
TE
R D
R
BL
O
O M
IN
G
TO
N
, M N
2-
6-
4/
/2
1:
:1
PM
S-001
Q
JV
F1
FY
P -3
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
G
EN
ER
AL
N O
TE
S
- S H
EE
T
ES
B
BB
B
C G
M M
IN
O
T
AF
B , N
O R
T H D
AK
O
TA
4/
/1
M
IA
8S -0
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
8. MATERIALS (CONTINUED):
B. STRUCTURAL AND MISCELLANEOUS STEEL: SECTIONS 051200, 055013
1. STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN
ACCORDANCE WITH AISC STEEL CONSTRUCTION MANUAL, 14th EDITION.
2. TEMPORARY ERECTION BRACING SHALL BE DESIGNED AND PROVIDED BY THE CONTRACTOR
AS REQUIRED AND SHALL NOT BE REMOVED UNTIL ALL PERMANENT LATERAL-LOAD-RESISTING
ELEMENTS AND CONNECTIONS ARE COMPLETELY INSTALLED.
3. WIDE FLANGE SHAPES AND TEES: ASTM A992, Fy = 50 KSI.
4. OTHER SHAPES, PLATES, AND THREADED RODS
a. ASTM A36, Fy = 36 KSI, UNLESS NOTED OTHERWISE.
b. ASTM A572 GRADE 50, Fy = 50 KSI, WHERE INDICATED AS "(50)".
5. SQUARE AND RECTANGULAR HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE
B, Fy = 46 KSI.
6. PIPE: ASTM A53 TYPE E OR S, GRADE B, Fy = 35 KSI.
7. BOLTS
a. 3/4" DIAMETER ASTM A325, UNLESS NOTED OTHERWISE.
b. FRAMING CONNECTIONS: PRETENSIONED JOINTS WITH STANDARD HOLES, UNLESS
NOTED OTHERWISE.
8. WELDING: IN ACCORDANCE WITH AWS D1.1 USING E70 ELECTRODE, WITH LOW HYDROGEN
WHERE REQUIRED.
9. HEADED STUDS
a. COLD-FINISHED STEEL CONFORMING TO ASTM A108, GRADE 1015 OR 1020.
10. ANCHOR BOLTS
a. ASTM F1554 GRADE 36.
b. LOCATE ANCHOR BOLTS ACCURATELY, SET WITH TEMPLATES, AND SECURELY HOLD IN
POSITION WHILE PLACING CONCRETE. PROTECT IN-PLACE ANCHOR BOLTS
FROM CONSTRUCTION ACTIVITY.
c. THE FOLLOWING ARE PROHIBITED WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING
OF THE STRUCTURAL ENGINEER OF RECORD:
(1) INSERTING ANCHOR BOLTS INTO FRESH OR PARTIALLY HARDENED CONCRETE.
(2) SUBSTITUTING POST-INSTALLED ANCHORS WHERE EMBEDDED ANCHOR BOLTS
ARE INDICATED.
(3) REPAIRING, REPLACING, OR MODIFYING INSTALLED ANCHOR BOLTS.
11. POST-INSTALLED ANCHORS: BASIS OF DESIGN IS HILTI HIT HY 200 OR APPROVED EQUAL.
ALL POST-INSTALLED ANCHORS SHALL COMPLY WITH IBC 2012.
12. GROUT: CEMENTITIOUS NONSHRINK.
C. STEEL JOISTS: SECTION 05 21 00
1. STEEL JOISTS, BRIDGING, AND ACCESSORIES SHALL BE DESIGNED, FABRICATED,
AND ERECTED IN ACCORDANCE WITH SJI SPECIFICATIONS.
2. JOISTS CALLED OUT ON THE CONTRACT DRAWINGS ARE SIZED FOR EQUIVALENT
UNIFORM GRAVITY LOADS ONLY. SUPPLIER SHALL FURTHER DESIGN AND MODIFY
JOISTS AS REQUIRED FOR ALL ADDITIONAL DISTRIBUTED AND CONCENTRATED
DEAD, LIVE, WIND (INCLUDING UPLIFT), SNOW (INCLUDING DRIFT), AND OTHER LOADS
INDICATED ON THE CONTRACT DRAWINGS OR OTHERWISE PROVIDED BY
EQUIPMENT VENDORS.
3. ALL JOISTS SHALL BE CAPABLE OF SUPPORTING A 300 LB CONCENTRATED LOAD
AT ANY POINT ALONG THE TOP OR BOTTOM CHORD IN ADDITION TO ALL OTHER
LOADS INDICATED OR SPECIFIED.
4. JOISTS SHALL BE ATTACHED TO SUPPORTING STRUCTURAL MEMBERS OR BEARING
PLATES USING A MINIMUM 3/16" x 1 1/2" LONG FIELD FILLET WELD OR
1/2" DIAMETER ASTM A325-ST BOLT ON EACH SIDE OF THE JOIST SEAT, UNLESS
NOTED OTHERWISE. BOLTS SHALL BE USED FOR ALL NON-PANELIZED JOISTS OF
40 FT OR GREATER SPAN.
5. JOISTS SUPPORTING STEEL DECK SHALL BE INSTALLED TO PROVIDE A FLAT PLANE
FOR DECK ATTACHMENT. JOIST MODIFICATIONS AND SHIMS SHALL BE PROVIDED AS
REQUIRED.
6. THE FOLLOWING ARE PROHIBITED WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING
OF THE STRUCTURAL ENGINEER OF RECORD:
a. CHANGE OF JOIST DEPTH FROM THAT INDICATED.
b. USE OF BOLTS LARGER THAN 1/2" DIAMETER FOR JOIST ATTACHMENT.
c. ANY MODIFICATION OF JOISTS NOT DISCUSSED ABOVE.
D. STEEL DECK: SECTION 053000
1. STEEL DECK, ATTACHMENTS, AND ACCESSORIES SHALL BE DESIGNED, FABRICATED,
AND INSTALLED IN ACCORDANCE WITH SDI MANUALS AND AISI COLD-FORMED STEEL
DESIGN MANUAL.
2. ROOF DECK
a. 1 1/2", 20 GAGE, WIDE RIB WITH Fy = 33 KSI, Imin = 0.201 IN^4/FT, Smin = 0.234 IN^3/FT, GALVANIZED G90, TYP UNO.
3. ALL STEEL DECK AND DECK ATTACHMENTS SHALL BE CAPABLE OF RESISTING THE WIND
UPLIFT LOADS INDICATED ON THE CONTRACT DRAWINGS AND A SERVICE DIAPHRAGM SHEAR
OF 195 PLF.
4. ALL STEEL DECK SHALL CROSS A MINIMUM OF TWO SPANS. MINIMUM LENGTH OF END
LAPS AND BEARING AT ALL SUPPORTS SHALL BE 2".
5. ALL STEEL DECK SHALL BE SUPPORTED AT EDGES OF OPENINGS. ADDITIONAL SUPPORT
STEEL SHALL BE PROVIDED BY CONTRACTOR AS REQUIRED AND FABRICATED SO THAT DECK
RUNS CONTINUOUSLY OVER MINOR OPENINGS, WHICH SHALL NOT BE CUT UNTIL NEEDED BY
OTHER TRADES.
6. MINIMUM STEEL DECK ATTACHMENT SHALL BE AS FOLLOWS:
a. DECK SHALL BE FASTENED AT EACH END AND AT INTERMEDIATE SUPPORTS
BY 5/8" DIAMETER PUDDLE WELDS, 36/4 PATTERN.
b. SIDE LAP CONNECTIONS SHALL BE MADE AT SEAMS USING #10 SCREWS, 5 PER SPAN.
c. CONNECTIONS ALONG SIDE BOUNDARIES, RIDGE PLATES, AND ROOF SUB
FRAMING SHALL BE MADE AT 12" ON CENTER MAXIMUM.
d. PNEUMATIC FASTENERS AND/OR SCREWS SHALL NOT BE SUBSTITUTED WHERE
WELDS ARE SPECIFIED, BUT MAY BE USED IN TEMPORARY ATTACHMENT OF
STEEL DECK.
7. ACCESSORY PLATES (RIDGES, VALLEYS, ETC) SHALL HAVE A MINIMUM THICKNESS OF
0.0359 IN.
8. NOTHING SHALL BE HUNG FROM THE ROOF DECK UNLESS APPROVED IN WRITING BY THE
STRUCTURAL ENGINEER OF RECORD.
E. COLD-FORMED STEEL FRAMING: SECTION 054000
1. COLD-FORMED STEEL FRAMING SHALL BE DESIGNED, FABRICATED, AND ERECTED IN
ACCORDANCE WITH AISI COLD-FORMED STEEL DESIGN MANUAL AND SSMA
PUBLICATIONS AS APPLICABLE.
2. SUPPLIER SHALL DESIGN AND DETAIL ALL ENGINEERED COLD-FORMED METAL FRAMING
ELEMENTS, INCLUDING MEMBERS FOR WHICH SIZES ARE NOT INDICATED ON THE DRAWINGS
AND ANY TEMPORARY AND PERMANENT BRACING, FOR LOADS BASED ON THE CRITERIA GIVEN
ON DRAWING S-001.
3. SHAPE DESIGNATIONS
a. STUDS, JOISTS, TRACK, CHANNELS, AND FURRING CHANNELS: PER SSMA
PRODUCT TECHNICAL INFORMATION, INDICATING MEMBER DEPTH, STYLE,
FLANGE WIDTH, AND MATERIAL THICKNESS.
4. FRAMING MEMBERS
a. ASTM A653 GRADE 33, Fy = 33 KSI, UNLESS NOTED OTHERWISE.
b. ASTM A653 GRADE 50, Fy = 50 KSI, FOR MATERIAL THICKNESS 54 MILS OR
GREATER AND WHERE INDICATED AS "(50)".
5. FINISH: HOT-DIP GALVANIZE TO PROVIDE A COATING CLASS OF G90.
6. MECHANICAL FASTENERS: CORROSION-RESISTANT-COATED, SELF-DRILLING, SELF-
THREADING STEEL DRILL SCREWS WITH LOW PROFILE HEADS BENEATH SHEATHING AND
MANUFACTURER'S STANDARD HEADS ELSEWHERE.
7. WELDING: IN ACCORDANCE WITH AWS D1.1 OR D1.3, AS APPLICABLE.
8. ALL END CONNECTIONS FOR EXTERIOR STUDS SHALL BE DESIGNED FOR A FACTORED
HORIZONTAL FORCE PERPENDICULAR TO THE PLANE OF THE WALL AND EQUAL TO THE
REACTIONS DUE TO A UNIFORMLY DISTRIBUTED LOAD THAT DEVELOPS A MAXIMUM MOMENT
IN THE STUD EQUAL TO 1.21 TIMES ITS NOMINAL FLEXURAL CAPACITY.
9. LIGHTNING PROTECTION POLE FOUNDATION DESIGN REACTIONS
A. THE FOLLOWING NOMINAL (ASD) REACTIONS WERE USED FOR THE DESIGN OF THE LIGHTNING
PROTECTION POLE FOUNDATIONS. THESE REACTIONS WERE ESTIMATED BASED ON LOADS CALCULATED IN ACCORDANCE WITH ASCE 7-10 USING THE WIND AND ICE LOAD CRITERIA LISTED IN NOTE 6. SUBMIT REACTIONS FROM POLE MANUFACTURERS FOR VERIFICATION PRIOR TO PLACING FOUNDATION CONCRETE.
1. 76 FOOT LIGHTNING PROTECTION POLE:
a. AXIAL = 3,320 LBS
b. SHEAR = 3,290 LBS
c. MOMENT = 226,000 FT-LBS
2. 40 FOOT LIGHTNING PROTECTION POLE:
a. AXIAL = 1,700 LBS
b. SHEAR = 1,330 LBS
c. MOMENT = 46,500 FT-LBS
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
P
LO
T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X2
SO
LI
C
IT
AT
IO
N N
O
AF
2-
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
BU
R N
S
M cD
O N
N
EL
L
N O
R M
AN
C
EN
TE
R D
R
BL
O
O M
IN
G
TO
N
, M N
2-
6-
4/
/2
1:
:1
PM
S-002
Q
JV
F1
FY
P -3
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
G
EN
ER
AL
N O
TE
S
- S H
EE
T
ES
B
BB
B
C G
M M
IN
O
T
AF
B , N
O R
T H D
AK
O
TA
4/
/1
M
IA
8S -0
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
ELEVATION CALLOUT EXAMPLEDETAIL CALLOUT EXAMPLESECTION CALLOUT EXAMPLE
SECTION, DETAIL, AND ELEVATION
IDENTIFICATION SYSTEM
SECTION, DETAIL, AND ELEVATION
SYMBOL IDENTIFIERS
DRAWING SEQUENCE NUMBER
INDICATES WHERE TITLE IS
LOCATED (MAY NOT BE
PRESENT IF CALLOUT AND
TITLE ARE ON THE SAME
DRAWING)
LETTER OR
NUMBER
DESIGNATORONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR
(MAY NOT BE PRESENT IF
CALLOUT AND TITLE ARE
ON DRAWINGS WITHIN
THE SAME DISCIPLINE)
THE WORD "SECTION" MAY BE REPLACED WITH
"ELEVATION" OR "DETAIL"
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
A1 S-001
A1 S-001
SECTION
A1 S-001
A1 S-001
A1 S-001
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
P
LO
T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X2
SO
LI
C
IT
AT
IO
N N
O
AF
2-
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
BU
R N
S
M cD
O N
N
EL
L
N O
R M
AN
C
EN
TE
R D
R
BL
O
O M
IN
G
TO
N
, M N
2-
6-
4/
/2
1:
:1
PM
S-003
Q
JV
F1
FY
P -3
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
LE
G
EN
D
A
BB
R
EV
IA
TI
O
N S
ES
B
BB
B
C G
M M
IN
O
T
AF
B , N
O R
T H D
AK
O
TA
4/
/1
M
IA
8S -0
OZ OUNCE
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PEMP PRE-ENGINEERED METAL BUILDING
PEN PENETRATE
PERIM PERIMETER
PERP PERPENDICULAR
PJNT PROJECTION
PL PLATE
PLC PLACES
PREFAB PREFABRICATED
PS PIPE SUPPORT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
R RISER
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCE
REQD REQUIRED
REV REVISION
RM ROOM
S SOUTH
SB SHEAR BAR
SCHED SCHEDULE
SE SOUTHEAST
SECT SECTION
SF SWAY FRAME
SH SHEET
SIM SIMILAR
SLO SHORT LEG OUTSTANDING
SLP SLOPE
SLV SLEEVE
SP SPACE
SPEC SPECIFICATION
SQ SQUARE
SST STAINLESS STEEL
STD STANDARD
STIF STIFFENER
STIR STIRRUP
STL STEEL
STR STRAIGHT
STRL STRUCTURAL
STRUC STRUCTURAL
SW SOUTHWEST
SYMM SYMMETRICAL
T TON
T&B TOP AND BOTTOM
T/ TOP OF
T/C OR TOC TOP OF CONCRETE
T/P TOP OF PIER
T/STL OR
TOS
TOP OF STEEL
TEMP TEMPORARY
THD THREAD
THK THICK
THRU THROUGH
TOB TOP OF BOLT
TOG TOP OF GRATING
TOS OR T/S TOP OF STEEL
TRD TREAD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VEF VERTICAL EACH FACE
VERT VERTICAL
W WEST
W/ WITH
W/O WITHOUT
WD WIDE
WDT WIDTH
WP WORK POINT
WS WATERSTOP
WT WEIGHT
WWF WELDED WIRE FABRIC
FD FLOOR DRAIN
FDN FOUNDATION
FF FAR FACE
FL FLOOR
FLG FLANGE
FNSH FINISH
FS FAR SIDE
FT FEET
FUT FUTURE
GA GAGE
GALV GALVANIZE
GB GRADE BEAM
GHSE GREENHOUSE
GND GROUND
GR GRADE
GRTG GRATING
H SLAB THICKNESS
HDHSE HEADHOUSE
HEF HORIZONTAL EACH FACE
HEX HEXAGON
HG HIGH
HH HEADHOUSE
HK HOOK
HORIZ HORIZONTAL
HPT HIGH POINT
HR HAND RAIL
HS HIGH STRENGTH
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IF INSIDE FACE
IJ ISOLATION JOINT
IN INCHES
INTR INTERIOR
INVT INVERT
IR INSIDE RADIUS
JT JOINT
KB KNEE BRACE
KPL KICK PLATE
KSI KIPS PER SQUARE INCH
L ANGLE
LAD LADDER
LB POUND
LD DEVELOPMENT LENGTH
LG LONG
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLO LONG LEG OUTSTANDING
LLV LONG LEG VERTICAL
LNTL LINTEL
LONG LONGITUDINAL
LPT LOW POINT
LS LAP SPLICE
LVL LEVEL
MATL MATERIAL
MAX MAXIMUM
MC MOMENT CONNECTION
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MK MARK
MO MASONRY OPENING
N NORTH
NA NOT APPLICABLE
NE NORTHEAST
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
NW NORTHWEST
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
# POUNDS OR NUMBER
% PERCENT
& AND
@ AT
AA ALUMINUM ASSOCIATION
AB ANCHOR BOLT
ABT ABOUT
ACI AMERICAN CONCRETE INSTITUTE
ADH ADHESIVE
AGGR AGGREGATE
AHR ANCHOR
AISI AMERICAN IRON AND STEEL INSTITUTE
AL ALUMINUM
ALTN ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECT
ASTM AMERICAN SOCIETY FOR TESTING OF
MATERIALS
AWS AMERICAN WELDING SOCIETY
B/P BASE OF PIER
BC BOLT CIRCLE
BETW BETWEEN
BLDG BUILDING
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
C/C CENTER TO CENTER
CAP CAPACITY
CF CUBIC FEET
CHKR CHECKER
CIR CIRCLE
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLJ CONTROL JOINT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONCRETE OPENING
COL COLUMN
COMP COMPRESSION
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
CONTR CONTRACT
COORD COORDINATE
COR CORNER
COTR CONTRACTING OFFICER
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CTR CENTER
CTRD CENTERED
CY CUBIC YARD
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DK DECKING
DL DEAD LOAD
DN DOWN
DWG DRAWING
DWL DOWEL
E EAST
EA EACH
ED EQUIPMENT DRAIN
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMBED EMBEDMENT
EQ EQUAL
EQ SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATE
ABBREVIATIONS
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
IBC 2012 TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION
OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARDª
1. MATERIAL VERIFICATION OF COLD-FORMED STEEL DECK:
APPLICABLE ASTM
MATERIAL STANDARDS
2. INSPECTION OF WELDING:
AWS D1.4
ACI 318: SECTION 3.5.2
— X
X—
X—
a. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
b. MANUFACTURER'S CERTIFIED TEST REPORTS.
a. COLD-FORMED STEEL DECK:
AWS D1.3X—1) FLOOR AND ROOF DECK WELDS.
b. REINFORCING STEEL:
——1) VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER
THAN ASTM A 706.
——2) REINFORCING STEEL RESISTING FLEXURAL AND AXIAL
FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES,
AND BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL
WALLS OF CONCRETE AND SHEAR REINFORCEMENT.
3) SHEAR REINFORCEMENT
X—4) OTHER REINFORCING STEEL.
IBC 2012 TABLE 1705.3 REQUIRED VERIFICATION
AND INSPECTION OF CONCRETE CONSTRUCTION
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARDª IBC REFERENCE
1. INSPECTION OF REINFORCING STEEL. X ACI 318: 3.5, 7.1-7.7 1910.4
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE
WITH TABLE 1705.2.2, ITEM 2b.
AWS D1.4 ACI 318: 3.5.2 —
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE
ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE
STRENGTH DESIGN IS USED.
1908.5, 1909.1
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED
CONCRETE MEMBERS.
X ACI 318: 3.8.6, 8.1.3, 21.2.8 1909.1
5. VERIFYING USE OF REQUIRED DESIGN MIX. ACI 318: CH. 4, 5.2-5.4
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
X
ASTM C 172
ASTM C 31
ACI 318: 5.6, 5.8
1910.10
7. INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
__ ACI 318: 5.9, 5.10 1910.6, 1910.7,
1910.8
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
a. APPLICATION OF PRESTRESSING FORCES. ACI 318: 18.20
9. INSPECTION OF PRECAST CONCRETE :
10. ERECTION OF PRECAST CONCRETE MEMBERS. ACI 318: CH. 16
11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO
STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND
PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND
STRUCTURAL SLABS. ACI 318: 6.2
X
X
ACI 318: 8.1.3, 21.2.8
1904.2, 1910.2, 1910.3
X— ACI 318: 5.11- 5.13 1910.9
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
ACI 318: 6.1.1—
X—
FOR SI: 1 INCH = 25.4 MM
a. WHERE APPLICABLE, SEE ALSO SECTION 1705.11, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE.
b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN
APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE
APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK.
c. WHEN DIRECTED BY THE CONTRACT DOCUMENTS TO PROVIDE POST-INSTALLED ANCHORAGES THE FOLLOWING GUIDELINES SHALL BE
FOLLOWED:
1. A REPRESENTATIVE OF THE ANCHOR MANUFACTURER OR PROJECT SPECIAL INSPECTOR SHALL BE ON SITE TO OVERSEE THE
INSTALLATION OF THE FIRST FOUR ANCHORS FOR EACH TYPE OF ANCHOR INSTALLED. THIS MEASURE SHALL BE TAKEN FOR EACH INSTALLER OF THE ANCHORS. THIS SERVICE IS TYPICALLY PROVIDED FREE BY THE LOCAL ANCHOR REPRESENTATIVE.
2. THE FIRST FOUR ANCHORS SHALL BE TENSION TESTED ONCE INSTALLATION IS COMPLETE FOR 200% OF THE SERVICE LEVEL LOAD
CAPACITY AS SPECIFIED BY THE MANUFACTURER.
IBC 2012 TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK
CONTINUOUS DURING
TASK LISTED
PERIODICALLY DURING TASK
LISTED
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. — X
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. — X
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. — X
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X —
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY. — X
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
P
LO
T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X2
SO
LI
C
IT
AT
IO
N N
O
AF
2-
AS
IN
D
IC
AT
ED
AP
R
IL
W
F-
-B
-0
SY
M
D
AT
E
AP
PR
D
ES
C
R
IP
TI
O
N
BU
R N
S
M cD
O N
N
EL
L
N O
R M
AN
C
EN
TE
R D
R
BL
O
O M
IN
G
TO
N
, M N
2-
6-
4/
/2
1:
:1
PM
S-004
Q
JV
F1
FY
P -3
C
O N
ST
R
U C
T
AD
D
IT
IO
N
B
ST
AT
EM
EN
T O
F
SP
EC
IA
L
IN
SP
EC
TI
O
N S
ES
B
BB
B
C G
M M
IN
O
T
AF
B , N
O R
T H D
AK
O
TA
4/
/1
M
IA
8S -0
1. STATEMENT OF SPECIAL INSPECTIONS
A. THIS "STATEMENT OF SPECIAL INSPECTIONS" HAS BEEN PREPARED IN ACCORDANCE WITH IBC 2012, SECTION 1704.
B. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY QUALITY ASSURANCE
AGENCIES TO PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
C. EACH SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE
SATISFACTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE, FOR INSPECTION OF THE PARTICULAR TYPE OF
CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.
D. SPECIAL INSPECTION AGENCY SHALL SUBMIT INSPECTION REPORTS DURING CONSTRUCTION FOR VERIFICATION, INCLUDING FINAL REPORTS IN ACCORDANCE WITH IBC 2012, SECTION 1704.1.2.
E. SPECIAL INSPECTOR SHALL USE THE LATEST ISSUE OF THE STRUCTURAL DRAWINGS FOR ALL INSPECTIONS. SHOP
FABRICATION DRAWINGS SHALL NOT BE USED FOR SUCH PURPOSES.
F. THE FOLLOWING TABLES IDENTIFY THE MATERIALS, SYSTEMS, AND COMPONENTS FOR WHICH SPECIAL INSPECTION IS
REQUIRED.
2. TESTING REQUIREMENTS
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY TESTING AGENCIES TO
PROVIDE STRUCTURAL TESTING DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
B. TESTING AGENCY SHALL SUBMIT TEST RESULTS DURING CONSTRUCTION FOR VERIFICATION INCLUDING A FINAL REPORT
IN ACCORDANCE WITH IBC 2012, 1704.2.4.
C. THE TABLES BELOW IDENTIFY THE STRUCTURAL TESTS REQUIRED FOR THIS PROJECT.
3. STRUCTURAL OBSERVATIONS
A. CONTRACTOR SHALL RETAIN PRE-COORDINATED AND GOVERNMENT-APPROVED THIRD-PARTY REGISTERED DESIGN
PROFESSIONALS TO PROVIDE STRUCTURAL OBSERVATIONS DURING CONSTRUCTION IN ACCORDANCE WITH IBC 2012, CHAPTER 17.
B. EACH STRUCTURAL OBSERVER SHALL SUBMIT WRITTEN STATEMENTS IDENTIFYING FREQUENCY AND EXTENT OF
STRUCTURAL OBSERVATIONS AND ANY REPORTED
NOTES:
NOTES:
1. "—" = NOT APPLICABLE
2. O = OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT TO BE DELAYED PENDING THESE INSPECTIONS.
3. P = PERFORM THESE TASKS FOR EACH JOINT OR MEMBER.
4. QA = INSPECTION THAT THE WORK IS IN COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS
5. QC = INSPECTION THAT THE WORK IS PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS
6. ALL COSTS DUE TO SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2012, ACI 530-11 AND AISC 300-10 SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR. THIS INCLUDES ALL QC AND QA REQUIREMENTS INDICATED ON S-003H AND S-004H.
7. QUALITY CONTROL: CONTROLS AND INSPECTIONS IMPLEMENTED BY THE FABRICATOR OR ERECTOR, AS APPLICABLE, TO ENSURE
THAT THE MATERIAL PROVIDED AND WORK PERFORMED MEET THE REQUIREMENTS OF THE APPROVED CONSTRUCTION
DOCUMENTS AND REFERENCED STANDARDS.
8. QUALITY ASSURANCE: MONITORING AND INSPECTION TASKS PERFORMED BY AN EGENCY OR FIRM OTHER THAN THE FABRICATOR OR ERECTOR TO ENSURE THAT THE MATERIAL PROVIDED AND WORK PERFORMED BY THE FABRICATIOR AND ERECTOR MEET THE REQUIREMENTS OF THE APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED STANDARDS. QUALITY ASSURANCE INCLUDES
THOSE TASKS DESIGNATED "SPECIAL INSPECTION" BY THE APPLICABLE BUILDING CODE.
SY
M
D
AT
E
D
ES
C R
IP
TI
O N
AP
AISC 360-10 TABLE N5.4-1
INSPECTION TASKS PRIOR TO WELDING
INSPECTION TASKS PRIOR TO WELDING QC QA
WELDING PROCEDURE SPECIFICATION (WPSs) AVAILABLE P
MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
MATERIAL IDENTIFICATION (TYPE/GRADE)
WELDER IDENTIFICATION SYSTEM (1)
FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
• JOINT PREPARATION
• DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
• BACKING TYPE AND FIT (IF APPLICABLE)
CONFIGURATION AND FINISH OF ACCESS HOLES
FIT-UP OF FILLET WELDS
(1) THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR
MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYP.
CHECK WELDING EQUIPMENT
P
• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
PP
OO
OO
OO
OO
OO
—O
AISC 360-10 TABLE N5.4-2
INSPECTION TASKS DURING WELDING
INSPECTION TASKS DURING WELDING QC QA
USE OF QUALIFIED WELDERS O
NO WELDING OVER CRACKED TACK WELDS
ENVIRONMENTAL CONDITIONS
• WIND SPEED WITHIN LIMITS
• PRECIPITATION AND TEMPERATURE
WELDING TECHNIQUES
O
• INTERPASS AND FINAL CLEANING
• EACH PASS WITHIN PROFILE LIMITATIONS
• EACH PASS MEETS QUALITY REQUIREMENTS
OO
OO
OO
OO
OO
CONTROL AND HANDLING OF WELDING CONSUMABLES
• PACKAGING
• EXPOSURE CONTROL
WPS FOLLOWED
• SETTINGS ON WELDING EQUIPMENT
• TRAVEL SPEED
• SELECTED WELDING MATERIALS
• SHIELDING GAS TYPE/FLOW RATE
• PREHEAT APPLIED
• INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
• PROPER POSITION (F, V, H, OH)
AISC 360-10 TABLE N5.4-3
INSPECTION TASKS AFTER WELDING
INSPECTION TASKS AFTER WELDING QC QA
WELDS CLEANED O
ARC STRIKES
O
PP
PP
WELDS MEET VISUAL ACCEPTANCE CRITERIA
• CRACK PROHIBITION
• WELD/BASE-METAL FUSION
• CRATER CROSS SECTION
• WELD PROFILES
• WELD SIZE
• UNDERCUT
• POROSITY
SIZE, LENGTH AND LOCATION OF WELDS PP
K-AREA (1) PP
BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) PP
REPAIR ACTIVITIES PP
DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER PP
(1) WHEN WELDING…