W9128A-18-B-0006_-_Drawings_(Part_3_of_3).pdf
PDF 13 MB Posted
- Solicitation number
- W9128A-18-B-0006
About this file
Drawings (Part 3 of 3)
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
DN
MECH
SIPRNET
SECURITY
TEAM
MEDIA
CBRN OFF
SCA
CBRN NCO
CBRN SGM
OIC
NCOIC
CORR
6x x1
3" ø
3"ø
1 1/2"ø
M-302
MATCH LINE, FOR CONTINUATION SEE DWG. M-402
M
AT
C H
L
IN
E, F
O R
C O
N
TI
N U
AT
IO
N S
EE
D
W G
. M -4
M
AT
C H
L
IN
E, F
O R
C O
N
TI
N U
AT
IO
N S
EE
D
W G
. M -4
24x24 CD
200 CFM
24x24 CD
150 CFM
24x24 CD
200 CFM
24x24 CD
200 CFM
VAV-6VAV-5 VAV-7
VAV-10
VAV-9
VAV-11
VAV-8VAV-4VAV-3
VAV-14VAV-12
VAV-13
VAV-2VAV-1
VAV-15
24x24 CD 100 CFM 24x24 CD
100 CFM
24x24 CD
100 CFM
24x24 CD
200 CFM
24x24 CD
150 CFM
24x24 CD
125 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 CD
200 CFM
24x24 CD
30 CFM
24x24 CD
100 CFM
24x24 CD
100 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 CD
300 CFM
24x24 CD
300 CFM
24x24 CD
300 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 RAR
665 CFM
24x24 RAR
620 CFM
24x24 RAR
665 CFM
8x12 10x10
18x1014x12
8x8
10x108x8
6x6
16x10
8x10
24x1228x1232x16
6x6
8x10 6x8
14x10
16x8 24x6
24x6
20x1228x1232x14
4x810x8
6x6 6x6
4x8 4x8
6x6
6x10
8x6
10x8
8x6
4x86x6
14x8
8x14
12x12
10x10
14x10
12x12 12x12
24x24 CD
100 CFM
24x24 CD
450 CFM
M-301
M-305
M-306
M-306
VD VD VD
VD
VD
VD
VD VD
VD
VD
VDVD
VD
VD
12x6
12x6
FCU-11
24x24 CD
75 CFM
6x6
10x10
8" 8"
10" 8" 8"
10"
10" 10"
8"
8"
8"
6"
6"
6"
6x10
4x8
8"6" 8" 6" 6"6"
8"
8"
8"
8"
12"
12"
8x8
10x8
8x10
8"
8x8
10x10
24x24 CD
250 CFM
16x12
18x12 x1
1" COND
DRAIN
1 1/2" CHWS
1 1/2" CHWR
30x18
8x8 8x8
8x8 EXH. DUCT
UP TO
GOOSENECK
ON ROOF
32x16
8x10
3/4"ø
2" ø
2" ø
VD
VAV10
VAV8VAV7VAV9
VAV5 VAV6VAV4
VAV3
VAV1 VAV2
VAV15
VAV14
VAV12
VAV13
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
AHU-1
2" COND
DRAIN
1 1/2" CHWS
1 1/2" CHWR
THERMOSTAT
DIV CBRNE
MCP-OD
SPCL STAFF
SPCL STAFF
DIV G8
16x16 RAR
550 CFM
10x8
18x8
VD
THERMOSTAT
VD 6x4
6x6 SAR
50 CFM
8x6
6"10x10
14x6
14x6
14x10
14x10 8x8 RAR
125 CFM
8x8 RAR
145 CFM
6x6 RAR
70 CFM
6x6 RAR
70 CFM
6x66x6 6x6
22x22
8x6
8x8 RAR
145 CFM
6x6
6x6 RAR
70 CFM
6x6 RAR
70 CFM
6x6 RAR
90 CFM
6x6 RAR
70 CFM
6x6 RAR
25 CFM
6x6
TG
6x6 RAR
70 CFM
12x12 RAR
325 CFM
STORAGE
MEDIA
LOBBY
THERMOSTAT
VD VD VDVD
VD VDVD
VD
VD
VD
VD
VD VD
VD VD
IU-5
THERMOSTAT
IU5
DUCT
THERMOMETHER
DD
EE
FF
8x14
BAROMETRIC
DAMPER
16x16 RELIEF AIR
DUCT UP TO
GOOSENECK ON
ROOF THRU EXIST.
ROOF OPENING
24x24 RELIEF
GRILLE
18x12
M-301
6x6
FCU-9
12x6
6x6 CD
10 CFM
VD
6x4
THERMOSTAT
FCU11
FCU9
8x8 TG
6x6 TG
1/2"
1/4"
1/2"1/4"
OU-5 4" THK.
CONC. PAD
22x22
CH
W
S
DUCT SMOKE
DETECTOR
FIRE/SMOKE
DAMPER
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173114
M-405
18SB02
EN
LA
R G
ED
N
EW
H
VA
C
F
LO
O R
P L A
N
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
1/4" = 1'-0"1 ENLARGED NEW HVAC FLOOR PLAN 5
KEY PLAN
NOT TO SCALE
NOTE:
FOR DUCT PENETRATIONS THRU STRUCTURAL WALLS,
SEE STRUCTURAL DRAWINGS FOR PENETRATION DRAWINGS/
DETAIL TO AVOID EXISTING REBAR.
SB
M
-4
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
MECH
FIRE ALARM &
SPKR
CMD CNSLR
186 TEAM
ELECT
TR
MR2 CNSLR
SR CNSLR
CNSLR
190DI
V
RE
TE
NS
IO
N
MEDIA
MEDIA
PSYCHT
CH MED OPS
MED OPS
CNSLR
TEAM
JAN
CORR
2" ø
1 1/2"ø
1" ø1" ø
1" ø
1" ø
1 1/4"ø
M-302
MATCH LINE, FOR CONTINUATION SEE DWG. M-403
M
AT
C H
L
IN
E, F
O R
C O
N
TI
N U
AT
IO
N S
EE
D
W G
. M -4
10x12 OUTSIDE
AIR DUCT UP
TOGOOSENECK
ON ROOF
58x29
14x10
24x24 CD
120 CFM
24x24 CD
115 CFM
24x24 RAR
775 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 CD
225 CFM
24x24 CD
150 CFM
24x24 CD
150 CFM
24x24 CD
200 CFM
24x24 CD
100 CFM
24x24 CD
100 CFM
24x24 CD
100 CFM
24x24 CD
100 CFM
24x24 CD
50 CFM
24x24 CD
100 CFM
24x24 CD
75 CFM
24x24 CD
200 CFM
VAV-16
VAV-17
VAV-19
VAV-18
VAV-21
VAV-20
VAV-22
VAV-23
VAV-27
VAV-28
VAV-24
VAV-29
VAV-25
VAV-26
14x14 RAR
440 CFM
14x14 RAR
460 CFM
8x8 EAR
100 CFM
6x6 EAR
50 CFM
8x8 EAR
125 CFM
8x8 EAR
100 CFM
6x6 4x8
8x8 6x108x8
8x8
8x8
8x6
6x6
8x8
8x8
8x6
8x6
6x10
6x10
18x14 18x12 16x12
20x820x8 x1 x1
4x8
8x8
4x8
6x6
8x8
10x10
8x88x8
18x10
16x10
8x8
8x88x8
18x8
16x8
14x8
24x24 CD
100 CFM
x8
4x86x64x8
6x6
8x8
8x8
10x10
12x12 24x16
4x8
6x6
6x6
6x10 6x8
6x8
6x8 6x6
6x8
6x6
10x8 6x8
4x8
8x8 8x8
8x8 8x810x8
12x12
6x6
8x8
EF-3
EF-4
EF-7
14x10 14 x1
16x24 SA
DUCT DN.
16x24 SA
DUCT DN.
IU-2
2" CD
DN.
OU-3
8x8
10x12
DOAS-2
x1 x1
26x10
M-302
M-305
M-305
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
VD
BACKDRAFT
DAMPER
12x12
8x8
8x8
10x8
10x8
EF-1
8x8
8" 8"
8" 8"
6"
8"
8"
8"
6" 6"
6" 6"
6"
6"
6"
8"
6" 6"
6"
6x624x24 CD
75 CFM
6x6
6"
8x8
AHU-2
VAV16VAV17
VAV20
VAV21
VAV19
VA
V1
THERMOSTAT
THERMOSTAT
VAV24
EF7
IU2
VAV23
VAV25
VAV29
VAV28
VAV27
VAV26
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
T-STAT
T-STAT
VAV11
THERMOSTAT
THERMOSTAT
VAV22
THERMOSTAT
CORR
RESTROOM
MEN
RESTROOM
WOMEN
SHOWER
MEN 199
SHOWER
MEN
SURGEON
DIV SURGEON
DIV SURGEON
LOBBY
OU-2
IU-3
IU-3
THERMOSTAT
1/ 2" ø
1/ 4" ø
1/2"ø1/4"ø 1/2"ø
1/4"ø
1/ 2" ø 1/
4" ø
1/ 4" ø1/ 2" ø
1/4"ø1/2"ø
1/4"ø 1/2"ø
DIV SURGEON
4" THK. CONC. PAD
(TYP. OF 2)
10x12
24x12
VDVD
EMERGENCY HVAC
SHUTDOWN SWITCH
LOCATED IN LOBBY,
COORDINATE WITH FIRE
PROTECTION DWGS,
6x6 SAR
50 CFM
VD
6x6
M-303
6x6
6x6 RAR
80 CFM
8x6
6x6 RAR
115 CFM
8x8 RAR
150 CFM
6x6 RAR
115 CFM
6x6 RAR
90 CFM
6x6
6x6 RAR 85 CFM6x6
8x4
6x6
6x4
6x6
6x6 RAR
80 CFM
6x6 TG
6x6 RAR
80 CFM
6x6 RAR
40 CFM
6x6 RAR
80 CFM
8x8 RAR
80 CFM
8x8 RAR
150 CFM
10x12
VD
DUCT
THERMOMETHER
DUCT
THERMOMETHER
1 1/4"ø
1/
4" ø
1/
4" ø
1/
2" ø
1/
2" ø
3/4"ø
2" ø
3/4"ø
3/ 4" ø
1/ 2" ø1/ 4" ø
3/ 4" ø
DD
EE
FF
x
6x6 TG
6x6 TG
6x6 TG
6x6 TG
6x6 TG
6x6 TG
6x6 TG
6x6 TG
BACKDRAFT
DAMPER
6x6
8x8
VD
VD
VD
6x6 RAR
80 CFM
8x8
FIRE/
SMOKE
DAMPER
FIRE/SMOKE
DAMPER
FIRE/
SMOKE
DAMPER
FIRE/SMOKE
DAMPER
DUCT SMOKE
DETECTOR
FIRE/SMOKE
DAMPER
8x8 TG 150 CFM8x8 TG
150 CFM
8x6
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173115
M-406
18SB02
EN
LA
R G
ED
N
EW
H
VA
C
F
LO
O R
P L A
N
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
1/4" = 1'-0"1 ENLARGED NEW HVAC FLOOR PLAN 6
KEY PLAN
NOT TO SCALE
NOTE:
FOR DUCT PENETRATIONS THRU STRUCTURAL WALLS, SEE
STRUCTURAL DRAWINGS FOR PENETRATION DRAWINGS/ DETAIL
TO AVOID EXISTING REBAR.
SB
M
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
DN
3"ø
3" ø
3"ø
3"ø
3" ø
3" ø
CH-1
3" DIA. CHWS
& 3" CHWR
LINES UP
CHECK
VALVE
AIR SEPARATOR
(AS-1)CHEMICAL
POT FEEDER
(CF-1) BUTTERFLY VALVE
6" THK. CONC PAD,
SEE STRUCT. DWG.
FOR DETAIL
4" THK. CONC.
PAD
3/4"
BUTTERFLY VALVE
(TYP. OF 2)
2'
/3 2"
4' - 0 1/8"
CONCENTRIC
INCREASER
(2 1/2"x3")
(TYP. OF 2)
FLEXIBLE
CONNECTION
(TYP. OF 2)
DD
EE
PIPE SUPPORT,
SEE DETAIL 2/M-503
(TYP.)
3' - 7 21/32" 8' - 9 7/32"
8'
1/
2"
0'
6"
4' - 2 1/2"
5'
3/
22x22
15x20
32x16 x1
18x12
2" COND. DRAIN
UP TO CEILING
2" COND. DRAIN
DN. & TERMINATE
AT 3" FD
2" COND. DRAIN
DN. & TERMINATE
AT 3" FD 6" THK. CONC. PAD
M-301
M-305
M-306
MECH
1 1/2" CHWS &
1 1/2" CHWR UP
EWH-1
(P-14)
20x20 RA DUCT
UP
AHU-1
8' - 9 1/32"
6'
1/
2"
2'
/3 2"
2' - 1 5/16"
EE
M-301
M-302
26x10 x1
DOAS-2
24x16 x1
EWH-2 (P-15)
2" COND. DRAIN
UP TO CEILING
6" THK. CONC. PAD
2" COND. DRAIN
DN. & TERMINATE
AT 3" FD
1" COND. DRAIN
DN. & TERMINATE
AT 3" FD
2" COND. DRAIN
DN. & TERMINATE
AT 3" FD
4" THK. CONC.
PAD
IU-3
M-302
4" THK. CONC.
PAD
IU-2
3/4" COND. DRAIN
DN. & TERMINATE
AT 3" FD
MECH
MED OPS
MEDIA
TEAM
CNSLR
AHU-2
1 1/4" CHWS &
1 1/4" CHWR
UP
24x16 RA
DUCT UP
24x16 SA
DUCT UP 4'
/1
6"
8' - 0 19/32"
1' - 11 13/16"
2'
5/
3' - 2 11/16"
1'
7/
1/2" RS & 1/4" RL
LINES UP
EE
MECH
SUPRVSR
DCSM
M-303
18x12 SA DUCT
UP
14x14 OA
DUCT UP
6" THK. CONC.
PAD
DOAS-1
OU-1
FLEX. CONN.
(TYP.)
1 1/4"
CHWS UP
COND. DRAINS
TERMINATE AT
3" FD 1 1/2" COND.
DRAIN UP
1" COND.
DRAIN UP
1 1/2"
1 1/2"
1"
1/2" & 1/4"
REFRIG.
PIPE UP
4" THK
CONC. PAD
2'
- 1
/1 6"
BB
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173116
M-407
18SB02
EN
LA
R G
ED
N
EW
H
VA
C
F
LO
O R
P L A
N
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
1/4" = 1'-0"4 ENLARGED NEW HVAC FLOOR PLAN - CH-1
1/4" = 1'-0"2
ENLARGED NEW HVAC FLOOR PLAN -
AHU-1
1/4" = 1'-0"3
ENLARGED NEW HVAC FLOOR PLAN -
AHU-2
KEY PLAN
NOT TO SCALE
1/4" = 1'-0"1
ENLARGED NEW HVAC FLOOR PLAN -
DOAS-1
SEE ENLARGED
PLAN 1/M-407
SEE ENLARGED
PLAN 2/M-407
SEE ENLARGED
PLAN 3/M-407
NOTE:
FOR DUCT PENETRARIONS THRU STRUCTURAL WALLS, SEE STRUCTURAL
DRAWINGS FOR PENETRATION DRAWINGS/DETAIL TO AVOID EXISTING
REBAR.
SB
M
CEILING
AIR FLOW
TYP. FAN COIL UNIT MOUNTING DETAIL
NOT TO SCALE
AHU MOUNTING DETAIL
NEOPRENE COATED
UNIT
ROD (TYP.)
AIR HANDLING
1/2" DIA HANGER
NOT TO SCALE
SPRING
MIN. 1" DEFLECTION
SOLE PLATE
WASHER, TOP & BOTTOM
DOUBLE NUTS W/ LOCK
MOUNT ON THE CONC.
(TYP.)
(TYP.)
ISOLATOR, MIN. 1"
VIBRATION SPRING
DEFLECTION
EXPANSION SHIELD
GALV. HOUSING
EXPANSION BOLT
3/8" DIA. x 4" LONG
HOT DIPPED GALV.
(TYP.)
3/8" DIA. HOT DIPPED
GALV. BOLT & NUT W/
AHU SUPPORT PLATE
ATTACH SECURELY
ACCOUSTICAL NON
TOP AND BOTTOM
NEOPRENE PAD
TO SOLE PLATE
WASHER (TYP.)
AHU CHILLED WATER PIPING CONNECTION
NOT TO SCALE
(TYP.)
CLEANOUT
CONDENSATE DRAIN
LINE
STRAINER & C/O
VALVE
CHWS
UNION (TYP.)
THERMOMETER (TYP.)
PRESSURE GAUGE (TYP.)
COOLING COIL
AUTO AIR VENT
0 - 100 PSI
SUPPLY AIR TEMPERATURE
(TYP.)
0 - 100°F
SENSOR
TO AHU
T
1C
FROM FCU
1C
(TYP.)
PLUG VALVE
CIRCUIT SETTER
FLOW CONTROL
CHWR
3-WAY MODULATING
CONTROL VALVE
TYPICAL CHILLED WATER PIPE
THRU WALL DETAIL
NOT TO SCALE
(3 PCF)
MEDIUM DENSITY
PACK FIBERGLASS
INSULATION TO
SLEEVE
INSULATION
SOLID GROUT TO
1/2" TO 3/4" CLEARANCE
1" MIN. THICKNESS
SUCH AS U.S. GYPSUM
RESILIENT CAULKING
CONTINUOUS DENSE
(BOTH ENDS)
ACOUSTIC SEALANT
EXIST. CMU WALL
PIPE
OU MOUNTING DETAIL
NOT TO SCALE
TOP OF CONCRETE
SLAB
ACCU GALV. EXPANSION BOLT
5/8" x 3" LONG
WITH WASHER
ISOLATOR PADS
4"x4"x1" THK. NEOPRENE
BASE PLATE
EQUIPMENT
CASING
(TYP.)
DETAIL
1/2" HANGER
EXHAUST FAN
UNIT
ROD (TYP.)
DOUBLE NUTS W/ LOCK
WASHER, TOP & BOTTOM
MOUNT ON THE CEILING
MOUNTING BRACKET
NOT TO SCALE
EXPANSION SHIELD
SLAB (TYP.)
FLEXIBLE
CONNECTION
FAN
IN-LINE FAN MOUNTING DETAIL
1/2" 0 THREADED
SPRING ISOLATOR
( TYP. OF 4 )
ROD
( TYP. )
MOUNT ON THE CEILING
EXPANSION SHIELD
SLAB (TYP.)
NOT TO SCALE
(TYP.)
UNDER
DUCTWORK
#10 SHEET METAL
SCREWS @ 6" O.C.
BEND STRAP
TYPICAL DUCT SUPPORT DETAIL
NOTE:
FOR MOUNTING
SEE DETAILS ABOVE
1. USE SPECIFIED SPACING AND NOT LESS THAN ONE
SUPPORT
PER
BRANCH.
2. DUCT STRAP AND ATTACHMENT DEVICES SHALL BE SIZED PER SMACNA
3. TOUCH-UP BARE METAL W/ ZINC-RICH GALV. COATING AND PAINT TO
NOT TO SCALE
TURNING VANE
TYPICAL ELBOW DETAIL DETAIL
11/4" x 16 GA. GALV.
SHEET METAL STRAP
(TYP.)
TURNING VANE
SPLITER DAMPER
NOT TO SCALE NOT TO SCALE
2" MIN.
COND DRAIN
3/4" THK.
INSULATION
EXHAUST DUCT/
DUCT SIZE
+ 25%
1/4" MESH S.S.
BIRDSCREEN
180°
W/ NEOPRENE GASKET &
RUBBERIZED WEATHER
STAINLESS STEEL SCREW
SEALER
PAINT TO MATCH EXTERIOR
GALVANIZED SHEET
METAL GOOSENECK AND
ROOF CAP
ROOF GOOSENECK DETAIL
NEW ROOF
CURB
FLASHING AND
PROVIDE WATERPROOF
COUNTER FLASHING
STAINLESS STEEL OR
EXIST. ROOF
NOT TO SCALE
OUTSIDE AIR DUCT
M-501
M-501
M-501
M-501
M-501
M-501
M-501
M-501
M-501
M-501
M-501
TO AVOID VERTICAL AND HORIZONTAL REBARS,
ADJUST LOCATION OF PENETRATION AS REQUIRED
NOTE:
SEE STRUCTURAL SHEET S-501.
(TYP.)
CONDITION CEILING
CEILING CONDITION
ANGLE IRON FOR STEEL
CONDITION
STEEL CEILING
ANGLE IRON FOR
CEILING EXHAUST FAN MOUNTING TYPICAL SPLITTER DAMPER
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173117
M-501
18SB02
M
EC
H
AN
IC
AL
D
ET
AI
L
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
-5
'zoom p 'zoom w
TYPICAL CONDENSATE DRAIN PIPE
SUPPORT DETAIL
NOT TO SCALE
6"x6"x4" BRICK
GALV. STEEL
PLATE CLAMP
CONDENSATE PIPE
GALV. STEEL
PLATE
GALV. SCREW
VA
RI
ES
(TYP.)
TYPICAL REFRIGERANT PIPING SCHEMATIC
NOT TO SCALEM-502
OUIU
SIGHT GLASS
CARTRIDGE TYPE
FILTER DRYER
BALL VALVE
(TYP.)
TXV, TYP.
(TYP.)
(TYP.)
CHARGING VALVE
(TYP.)
PACK TIGHT WITH
FIRE SAFING
DUCT THRU WALL DETAIL
NOT TO SCALE
ALL AROUND
OAKUM
CAULK
INTERIOR WALL-
CUT SMOOTH HOLE.
CEMENT GROUT-
TROWEL SMOOTH.
ALL AROUND
CAULK 1"
SA/RA DUCT
SLEEVE
(TYP.)
VALVES
REFRIGERANT ISOLATION
2"x2"x3/16" THICK
TYPICAL DOAS MOUNTING DETAIL
NOT TO SCALE
SUPPORT
ANGLE IRON
3/8" HANGER
(TYP. OF 4)
SPRING VIBRATION
ISOLATORS
ROD
DOAS
SECURE FAN
COIL UNIT TO
SUPPORT
LOCK WASHER
DOUBLE NUT W/
DOAS COIL PIPING DIAGRAM
NOT TO SCALE
UNION
COOLING COIL
AIR VENT BALL
VALVE WITH CAP
2-WAY MODULATING
VALVE
REDUCER
CALIBRATED
BALANCING VALVE
BALL
VALVE
(TYP.)
CHWS PIPING
STRAINER W/ DRAIN VALVE,
HOSE CONNECTION & BRASS
CAP
CHWR PIPING
PETE'S PLUG
(TYP.)
NOT TO SCALE
INSULATED PIPE THRU WALL DETAIL
COOLING COIL
COIL AIR VENT VALVE
WITH PLUG
THERMOWELL
THERMOMETHER WITH
(TYP.)
(TYP.)
AIR VENT, BALL VALVE
WITH CAP
CHWR PIPING
CHWS PIPING
BUTTERFLY (2" & OVER)
BALL VALVE (UP TO 1 1/2")
1 1/2" DRAIN WITH
BALL VALVE & HOSE
DI-ELECTRIC UNION
(TYP.)
COUPLING
(TYP.)
GAGE COCK
PRESSURE GAGE WITH
(TYP.)
FLOW CONTROL
UNION
VALVE
2-WAY MODULATING
REDUCER
VALVE
CONC. SLAB
TOP OF EXISTING
18 GA. GALV. SHEET
SCH. 40 STEEL PIPE
2" DIA. GALVANIZED
SUPPORT
METAL SADDLE
(ADJUSTABLE)
CHILLED WATER PIPE
WITH INSULATION
6"X 6"X 1/4" THK. GALV.
STEEL PLATE (HOT
DIPPED)
1/2" DIA. X 3" LONG
GALV. EXPANSION
BOLT (HOT DIPPED)
1/2" GROUT
EXIST. CMU WALL
PIPE IS EXPOSED
WALLS WHERE
FOR FINISHED
ESCUTCHEON
CAST-IN-PLACE
PIPE SLEEVE
SEALANT
C PIPE
THRU FIRE RATED WALL
FIRE STOP WHEN PASSING
INSULATION
BACK UP MATERIAL
ALUMINUM JACKET
DRAW BAND
L
AHU COOLING COIL PIPING DIAGRAM
NOT TO SCALE
Y-STRAINER WITH BLOWOFF VALVE,
HOSE CONNECTION & BRASS CAP
CHW PIPE SUPPORT DETAIL
NOT TO SCALE
26 GA. x 4" WIDE
PROTECTIVE SHIELD
AROUND INSULATION
SCHEDULE
HANGER ROD
(TYP.)
3/8" o
PIPE HANGER SUPPORT DETAIL
CONTROL HANGER
SPRING VIBRATION
BOLTS (TYP.)
GALV. STEEL
CONC. SLAB
TRAPEZE TYPE
TO SUIT
UNISTRUT
SHIELD
EXPANSION
1/2"- 2" "- 3
SIZE
/2 21 2/1 "
PIPE
STAINLESS STEEL
INSULATION
PIPE WITH
GALV. STEEL
CLAMP
CLEVIS TYPE
1/2" o/
SIZE
ROD
FLARED
EDGES
NOTCHED TO
FIT PIPE HANGER
CORNERS
ARE CLIPPED
LENGTH = TWICE
INSULATION O.D.
FLARED END
NOTE:
EDGES TO PIPE INSULATION
HANGER. VAPOR SEAL
BEARING PLASTIC THROUGH
USE HIGH DENSITY LOAD
FOR FOAMED PLASTIC,
HANGER UNBROKEN
ALL INSULATION
PIPE SADDLE HAS
FLARED EDGES
(SEE SPEC.)
PIPE HANGER
(TYP.)
GLASS INSULATION AT ALL
PIPE HANGER LOCATIONS
PROVIDE CELLULAR
PASSES THRU
NOT TO SCALE 3"x2"x3/16" GALV.
ANGLE IRON
M-502
M-502
M-502
M-502
M-502
M-502
M-502
M-502
PIPE HANGER SUPPORT DETAIL
NOT TO SCALEM-502
HORIZONTAL REBARS, SEE STRUCTURAL
AS REQUIRED TO AVOID VERTICAL AND
ADJUST LOCATION OF PENETRATIONS
NOTE:
DWG. SHEET S-501.
SEE STRUCTURAL SHEET S-513 FOR DETAILS.
PROIDE SEISMIC PROTECTION PER SECTION 13 4800.00 10,
NOTE:
TO AVOID VERTICAL AND HORIZONTAL REBARS,
ADJUST LOCATION OF PENETRATION AS REQUIRED
NOTE:
SEE STRUCTURAL SHEET S-501.
(TYP.)
GAGE COCK
PRESSURE GAGE WITH
(TYP.)
THERMOWELL
THERMOMETHER WITH
(TYP.)
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173118
M-502
18SB02
M
EC
H
AN
IC
AL
D
ET
AI
L
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
M-503
M-503
M-503
M-503
M-503
M-503
M-503
M-503
M-503
EXPANSION TANK BASE
CHARGING VALVE
CW LINE TO PUMP
EXPANSION TANK
LIFTING RING
CONC. FLOOR SLAB
INLET
RING SUPPORT@ WALL OR COLUMN
INSTALL UP 60" AFF
BALL VALVE,
FACTORY WELDED
SUPPORTS
( TYP. OF 2 )
PIPE SUPPORTS, SEE
DETAIL
AUTO VENT
1/2" HANGER ROD
( TYP. OF 2 )
PIPE
BUTTERFLY VALVE
FLOW
NOT TO SCALE
ISOLATOR MOUNTING DETAIL
NOT TO SCALE
CHILLED WATER PIPE SUPPORT DETAIL
NOT TO SCALE
AIR SEPARATOR MOUNTING DETAIL
NOT TO SCALE
EXPANSION TANK MOUNTING DETAIL
CHEMICAL FEEDER MOUNTING AND SCHEMATIC
NOT TO SCALE
BALL VALVE
(TYP)
(HOT DIPPED)
GALV. STEEL PIPE
WELD 2" DIA. GALV.
PIPE TO 8x8x3/8
THICK GALV. STEEL PLATE
2" DIA. HOT DIPPED
EXP. BOLT WITH
1" GROUT
WASHER
CONC. FLOOR SLAB
1/2" DIA. X 4" LONG
HOT DIPPED GALV.
INSULATION
COPPER PIPE
2" THICK
CL
PIPE SUPPORT ON FLOOR DETAIL
NOT TO SCALE
TANK
1/2" DIA. x 3" LONG
GALV. STEEL EXP. BOLT
(TYP. OF 4)
CHECK VALVE
BALL VALVE
UNION (TYP.)
CHEMICAL FEEDER
(TYP.)
CHWS
CHWR
2 1/2" DIA. HOT DIPPED
REDUCING BUSHING
6" x 6" x 1/4" THK. HOT DIPPED
GALV. STEEL PIPE
CONC. SLAB
GALV. STEEL PLATE
DISCHARGE
2" WIDE x 1/8" THK.
STRAP (ANCHOR TO
SUCTION
TO PUMP
BOLT & NUT
(TYP.)
STAINLESS STEEL
PIPE CLAMP W/
DIELECTRIC SHEET
BETWEEN PIPE & CLAMP
1/2" HOSE END VALVE
& BRASS CAP
3/4" DRAIN LINE
WITH DRAIN
VALVE, HOSE END
& BRASS CAP
4EA - 2"x2"x1/2" ANGLE WITH
ANCHOR BOLTS 90° APART
(HOT DIPPED)
3/4" DRAIN LINE WITH DRAIN
VALVE, HOSE END & BRASS
CAP
TERMINATE 6" ABOVE
FLOOR NEAR WALL
DIPPED GALV. EXP.
BOLT WITH WASHER
EXIST. CONC.
PAD
MIN. 1" DEFLECTION
NEOPRENE COATED
SPRING VIBRATION
ISOLATORS W/ SEISMIC
VERTICAL RESTRAINT
5/8" x 4" LONG HOT
(TYP.)
CHILLER
WITH WASHER
(TYP.)
5/8" HOT DIPPED
GALV. BOLT & NUT
ACCOUSTICAL NON
TOP AND BOTTOM
NEOPRENE PAD
" M
IN
18 GAUGE x 12" LONG GALVANIZED
SHEET METAL INSULATION SHIELDS
1/8"x2"x2" ANGLE IRON WELDED TO
PIPE SUPPORT
18 GAUGE GALVANIZED SHEET
METAL SADDLE BOTH SIDES.
1/8" U-BOLT
(TYP.)
INSULATED CHILLED
WATER PIPES W/
ALUMINUM JACKET
AS REQ'D
2" GALVANIZE
SCHEDULE 40 STEEL
PIPE SUPPORT
WELDED TO PLATE
SECURED TO CONCRETE
SLAB 86 LONG (GALV)
EXPANSION BOLT
CONCRETE SLAB OR
BLOCK 1" THK. GROUT (FOR MOUNTING ON
CONCRETE SLAB)
6"x6"x1/8" THK. GALV. STEEL PLATE
(HOT DIPPED)
CHILLER VIBRATION
WALL SUPPORT
(TYP. OF 4)
CONCRETE
SLAB
(TYP.)
2"x2" ANGLE GALV.
18" MIN
30" MAX
3/8" GALV. SCREW
WALL SUPPORT
2" WIDE GALV PIPE
CLAMP BOLTED TO
(TYP. OF 4)
TEST COCK
BACKFLOW PREVENTOR
REDUCE PRESSURE
BALL VALVE
BACKFLOW PREVENTER MOUNTING DETAIL
(TYP. OF 4)
NOT TO SCALE
1/2" DIA. x 3" LONG
GALV. STEEL EXP. BOLT
(TYP. OF 4) 6" x 6" x 1/4" THK. HOT DIPPED
CONC. SLAB
GALV. STEEL PLATE
3/4" CW SUPPLY
LINE
SLOPE DN.
SLOPE DN.
3/4" DRAIN LINE
FROM FCU
CONDENSATE DRAIN
MAIN LINE TO 3"
FLOOR DRAIN
DRAIN LINE CONNECTION DETAIL
NOT TO SCALE
DN
PUMP
HEAT EXCHANGER
FLOW SWITCH
PRESSURE RELIEF
FLEX CONNECTION
AIR SEPARATOR
MANUFACTURER
AND VENT
EXPANSION TANK
(SIZES 011 - 060 ONLY)
BALANCE VALVE/
DRAIN PLUG
TEMPERATURE
ACCESS PORT
STRAINER (40 MESH)/
BLOW-DOWN VALVE
ISOLATION VALVE
ELECTRIC HEATER
PRESSURE REDUCING/
FILL VALVE
AIR VENT
CONNECTION PORT
PRESSURE/
TEMPERATURE
ACCESS PORT
PRESSURE/
CONDENSATE
NOT TO SCALE
PROTOTYPE CHILLER WITH INTEGRAL PUMP
FACTORY SUPPLIED
PRESSURE GAUGE
(TYP. OF 2)
THERMOMETHER
PETE'S PLUG
(TYP. OF 2)
(TYP. OF 2)
(TYP. OF 2)
(TYP. OF 2)
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173119
M-503
18SB02
M
EC
H
AN
IC
AL
D
ET
AI
L
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
. 18
SB
M
M-504
M-504
M-504
M-504
CHWR
FLOW SWITCH
CHILLER CONNECTION DETAIL
INCREASER
(TYP.)
FS
FLEXIBLE
FLANGE
COUPLING
BUTTERFLY VALVE
COUPLING
ADAPTER
M
CHWS
(TYP.)
FLOW CONTROL
PRESSURE GAUGE
VALVE
(TYP.)
BUTTERFLY VALVE
THERMOMETER
NOT TO SCALE
TYP.
TYP.
TYP.
CONNECTION
FLEXIBLE
(TYP.)
CABLE
CONNECTION
TO ANGLE
8" HANGER ROD
REINFORCING EACH CORNER
VAV ACTUATOR
1/8" WIRE ROPE
(STRAND CORE) W/ 850#
BREAKING STRENGHT
EACH CORNER
THERMOSTAT
VAV
ACTUATOR
L 3"x3"x1/4"
CL 12" O.C.
(2 MIN EACH ANGLE)
VAV BOX INSTALLATION DETAIL
NOT TO SCALE
FLEX DUCT/
CEILING
DIFFUSER
VERIFY
SHEET METAL DUCT
W/ 2" THK DUCT LINER
AIR VELOCITY
1000 FPM MAX.
3 DIAMETERS
NO DAMPERS, ELBOWS, OR
OTHER FITTINGS ALLOWED
VAV
NOTES:
1. DO NOT LOCATED NON-FAN POWERED BOXES OF SPACES NC 35 OR LESS.
2. INSTALL FLEXIBLE DUCT ELBOW SUPPORTS AT ALL DIFFUSERS.
AIR VELOCITY
2000 FPM MAX.
SHOULD BE LOCATED AT
BRANCH TAKEOFFS AND FAR
AWAY FROM DIFFUSERS.
SUPPORT
MINIMUM
DIAMETERS
STRAIGHT DUCT FOR MIN.
DAMPERS, IF REQUIRED,
FLEXRIGHT DUCT ELBOW
3 DUCT
RIGID DUCT
CONCENTRIC
VALVE
MOTORIZED SHUT-OFF
2" DRAIN
PIPE OR EQUAL.
#2 CRUSHED
AMERICAN CONC.
PRE-CAST CONC.
MANHOLE CONE
NOTES:
DIAMETER
ROCKS
CAST IRON SD MANHOLE
4" S
4C
6" TOPSOIL
FRAME & COVER
6"
70" + 48"
5"
MORTAR
AROUND
24"
SECTION-
1" FINISHED GRADE
EXISTING OR
SEEPAGE PIT (DRYWELL) DETAIL
NOT TO SCALE
2. CORE THRU PRECAST CONCRETE MANHOLE WALL AND MORTAR
AROUND 2" DRAIN PIPE.
1. USE PRECAST CONCRETE CONE SECTION WITHOUT RUNGS.
NOT TO SCALE
CHILLED WATER PIPE SUPPORT DETAIL
7'- 6 1
/2"
18 GAUGE x 12" LONG
GALVANIZED SHEET METAL
INSULATION SHIELDS
1/8"x2"x2" ANGLE IRON
WELDED TO PIPE SUPPORT
18 GAUGE GALVANIZED
SHEET METAL SADDLE
BOTH SIDES.
1/8" U-BOLT
(TYP.)
INSULATED CHILLED
WATER PIPES W/
ALUMINUM JACKET
AS REQ'D
2" GALVANIZE
SCHEDULE 40 STEEL
PIPE SUPPORT
WELDED TO PLATE
SECURED TO CONCRETE
SLAB 86 LONG (GALV)
EXPANSION BOLT
CONCRETE SLAB OR
BLOCK 1" THK. GROUT (FOR
MOUNTING ON CONCRETE
SLAB)
6"x6"x1/8" THK. GALV. STEEL
PLATE (HOT DIPPED)
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173120
M-504
18SB02
M
EC
H
AN
IC
AL
D
ET
AI
L
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
. 18
SB
M
TAG LOCATION
FLA VOLTS PHASE HZ
WATER COND. (°F)
LVG.ENT.
AIR HANDLING UNIT SCHEDULE
MOTOR
(HP)
ELECTRICAL
REMARKS
4,700 1,100 45.0 55.0 14.3 208 3 605 943 WITH UV LIGHTS112.23 94.86 2.0
ENT. AIR COND.
WB (°F)DB (°F)
71.7 61.22.73
LVG. AIR COND.
WB (°F)DB (°F)
53.0 52.7
COOLING COIL
PD (FT.)
22.4 1.7
FLOW
(GPM)
No. OF
ROWS
AHU
1 A
2,805 615 45.0 55.0 6.2 208 3 602 43162.3 57.1 1.0 73.3 61.01.18 54.0 52.9 12.4 2.636
AHU
1 A
TAG LOCATION
FLA VOLTS PHASE HZ
WATER COND. (°F)
LVG.ENT.
DEDICATED OUTDOOR AIR SYSTEM
MOTOR
(HP)
ELECTRICAL
REMARKS
1100 1100 45.0 55.0 3.1 208 3 601.0 37277.73 29.03 2.0
ENT. AIR COND.
WB (°F)DB (°F)
80.2 76.62.46
LVG. AIR COND.
WB (°F)DB (°F)
55.2 55.2
COOLING COIL
PD (FT.)
15.4 7.0
FLOW
(GPM)
No. OF
ROWS
DOAS
1 A
615 615 45.0 55.0 3.3 208 3 600.75 22443.5 16.1 1.0 80.21.31 56.8 56.8 6.5 6.76
DOAS
1 B
800 800 45.0 54.9 3.3 208 3 600.75 27854.6 20.3 1.0 80.21.34 55.5 55.5 11.0 21.16
DOAS
1 B
505 505 45.0 55.0 3.3 208 3 600.75 22438.8 14.5 0.50 80.20.66 54.5 54.5 6.8 7.16
DOAS
1 B
TAG LOCATION
MOCP VOLTS PHASE HZ
AIR-COOLED CHILLER
ELECTRICAL
REMARKS
52.56 44 300 208/230 3 60254.5 2,950 WITH INTEGRAL DUAL PUMPS47.28 132.0 R410A 958.8
CH
CONN.
TYPE MCA
1 102.2 67.4
EXTERNAL
TO CHILLERAT PUMP
PUMP DYNAMIC HEAD (FT.)
QTY.
SINGLE
POINT
COND.
ENT. AIR
(°F)
REFRIG.
PD
(FT. WG.)
FLOW
RATE
(GPM)
LWT
(°F)
CAPACITY
(TONS)
SEE PLAN
EWT
(°F)
MECH 169
MECH 141
UNIT TYPE: A - INDOOR MOUNTED CENTRAL STATION AIR HANDLING UNIT .
B - INDOOR MOUNTED 2-PIPE, BELT-DRIVEN.
MECH 184
UNIT
TYPEQTY. TSP
(IN. WG.)
ESP
(IN. WG.)
OUTSIDE
AIR CFM
TOTAL
CAPACITY
(MBTUH)
SENSIBLE
CAPACITY
(MBTUH)
MECH 141
SUPPLY
AIR CFM
UNIT TYPE: A - INDOOR MOUNTED CENTRAL STATION AIR HANDLING UNIT .
MECH 184
UNIT
TYPEQTY. TSP
(IN. WG.)
ESP
(IN. WG.)
OUTSIDE
AIR CFM
TOTAL
CAPACITY
(MBTUH)
SENSIBLE
CAPACITY
(MBTUH)
MECH 118
SUPPLY
AIR CFM
WEIGHT
(LBS)
WEIGHT
(LBS)
WEIGHT
(LBS)
MCA
17.9
7.7
MOCP
MCA
3.9
MOCP
76.6
76.6
76.6
WITH INTEGRAL EXPANSION TANK
CHILLER ENCLOSURE
WITH UV LIGHTS
WITH UV LIGHTS
WITH UV LIGHTS
WITH UV LIGHTS
WITH UV LIGHTS
PUMP HP
EA.
7.5
NOTES:
1. PROVIDE CHILLER CASING WITH PSX-700 OR EQUAL COATING.
2. PROVIDE CHILLER COIL WITH BLYGOLD OR EQUAL COATING.
3. PUMP SHALL HAVE THE FOLLOWING ACCESSORIES:
a) STRAINER WITH BLOWDOWN VALVE
b) PRESSURE TAPS
c) DRAIN AND VENT VALVE
d) FLOW SWITCH
e) BALANCINF VALVE f ) CHECK VALVES
g) ISOLATIONS VALVES
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173121
M-601
18SB02
H
VA
C S
C H
ED
U
LE
S
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
. 18
SB
M
-6
TAG LOCATION
WB (°F)DB (°F)
INDOOR UNIT SCHEDULE
REMARKS
530 - 80.0 67.0 38
OU
IU
18,000 -
%RH
TAG LOCATION
OUTDOOR UNIT SCHEDULE
SEE PLAN 152
REMARKS
-95
MOCP VOLTS PHASE HZ
30 208/230 1 6019
MCA
ELECTRICAL
SEER
21.018,000 4,435
OU
OU
530 - 80.0 67.0 38
OU
IU
18,000 - --
SEE PLAN 15295 30 208/230 1 6019 21.018,000 4,435
TAG LOCATION
EXHAUST FAN SCHEDULE
ABOVE CEILING 65
REMARKS
SONES
3.5
SERVES CFM
600 0.25
WATTS VOLTS PHASE HZ
- 115 1 60
ELECTRICAL
EF
HP
1/6DIRECT
ABOVE CEILING 44 -3.5400 0.25 - 115 1 60
EF
1303 1/10DIRECT
CEILING 11 INTERLOCK W/ LIGHT SWITCH3.5100 0.25 128 115 1 60
EF
706 -DIRECT
CEILING 11 INTERLOCK W/ LIGHT SWITCH3.5100 0.25 128 115 1 60
EF
706 -DIRECT
ABOVE CEILING 24 INTERLOCK W/ LIGHT SWITCH3.5225 0.25 66.3 115 1 60
EF
926 -DIRECT
CEILING INTERLOCK W/ LIGHT SWITCH100
EF
113.50.25 128 115 1 60706 -DIRECT
CEILING T-STAT CONTROL150
EF
253.50.25 25.7 115 1 60708 -DIRECT
CEILING T-STAT CONTROL200
EF
253.50.25 43.5 115 1 60836 -DIRECTELECT 124 CEILING CABINET
ELECT 194 CEILING CABINET
WOMEN SHOWER 119 CEILING CABINET
MEN SHOWER 120 IN-LINE CABINET
WOMEN SHOWER 198 CEILING CABINET
MEN SHOWER 199 CEILING CABINET
MEN RESTROOM 121/
WOMEN RESTROOM 122/
JAN 123
CENTRIFUGAL
IN-LINE
DRIVEFAN
RPM
JAN 195/
WOMEN RESTROOM 196/
MEN RESTROOM 197
S.P.
(IN. WG)
CENTRIFUGAL
IN-LINE
FAN TYPE
INDOOR UNIT POWERED FROM OUTDOOR
UNIT; PROVIDE CONDENSATE PUMP
WALL-MOUNTEDTR 193
MIN. CAP.
(BTUH)
COND. AIR
TEMP.
(°F)
RATED CAP.
(BTUH)
INDOOR UNIT POWERED FROM OUTDOOR
UNIT; PROVIDE CONDENSATE PUMP
WALL-MOUNTED
E.S.P.
(IN. WG.)
INDOOR AIR CONDITION
OUTSIDE
AIR CFM
WT.
(LBS.)
SENS. CAP.
(BTUH)
INDOOR
UNIT TYPE
SUPPLY
AIR CFM
(HI-SPD)
OUTDOOR
UNIT
TOTAL CAP.
(BTUH)
TR 140
530 - 80.0 67.0 38FIRE ALARM & SPKR OU
IU
18,000 - --WALL-MOUNTED INDOOR UNIT POWERED FROM OUTDOOR
UNIT; PROVIDE CONDENSATE PUMP
OU
SEE PLAN 15295 30 208/230 1 6019 21.018,000 4,435
WT.
(LBS.)
WT.
(LBS.)
530 - 80.0 67.0 38
OU
IU
18,000 - --WALL-MOUNTED INDOOR UNIT POWERED FROM OUTDOOR
UNIT; PROVIDE CONDENSATE PUMP
OU
SEE PLAN 15295 30 208/230 1 6019 21.018,000 4,435
TR 173
530 - 80.0 67.0 38
OU
IU
18,000 - --WALL-MOUNTED INDOOR UNIT POWERED FROM OUTDOOR
UNIT; PROVIDE CONDENSATE PUMP
SIPRNET 104
OU
SEE PLAN 15295 30 208/230 1 6019 21.018,000 4,435
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173122
M-602
18SB02
H
VA
C S
C H
ED
U
LE
S
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
TAG SERVES
VARIABLE AIR VOLUME UNIT SCHEDULE
REMARKS
VAV
8250900
VAV
8250900
VAV
670375
VAV
425100
VAV
425100
VAV
VAV
425200
VAV
425150
VAV
8100750
VAV
425100
VAV
660450
VAV
425100
VAV
425130
VAV
660450
VAV
425200
VAV
425110
VAV
425100
VAV
425100
VAV
425100
VAV
460200
VAV
425200
VAV
425110
VAV
430150
VAV
425200
VAV
425150
VAV
425100
VAV
425115
VAV
425120
VAV
91401,050
14425100
-DIV SURGEON 177/
CORRIDOR
-CH MED OPS
-MED OPS 183
-PSYCHT
-SURGEON 179
-MEDIA 180
-TEAM 181
-CMD CNSLR-186
-MEDIA 188
DIV. RET. 185/
STORAGE187/
CORR 103
-SR CNSLR 191
-MR2 CNSLR 192
-CNSLR 190
-CNSLR 189
-MEDIA 113
-MCP-OD 112
-OIC 115/
STORAGE 114
-NCOIC 116
-LOBBY 100
-SECURITY 102
-DIV CBRNE
-TEAM 106
-MEDIA 107
-SCA 108
-CBRN NCO 109
-CBRN SGM 110
-CBRN OFF 111
-SPCL STAFF 117
-SPCL STAFF 117
INLET
SIZE
(IN.)
PRIMARY
MIN.
AIRFLOW
(CFM)
WT.
(LBS.)
PRIMARY
MAX.
AIRFLOW
(CFM)
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173123
M-603
18SB02
H
VA
C S
C H
ED
U
LE
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
TAG LOCATION COND. (°F)
LVG.ENT.
FAN COIL UNIT SCHEDULE
350 45.0 55.07,502 6,604 -
COND.
RH
(°F)
75.0 50HIGH
COND.
55.0 54.0
FCU
FAN
SPEED
ESP
(IN. WG.)
TOTAL
CAPACITY
(BTUH)
SENSIBLE
CAPACITY
(BTUH)
SUPPLY
M
WATERENT. AIR LVG. AIR
AIR
(CFM) DB
(°F)
DB
(°F)
WB
350 45.0 55.0129 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
M
350 45.0 55.0128 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
S
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0131 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
COPS
350 45.0 55.0145 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
DIV PAO
350 45.0 55.0142 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
DIV SAFTY
350 45.0 55.0143 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
SUPRVSR
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0144 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
MEDIA
350 45.0 55.0149 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
PA OFF
350 45.0 55.0146 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
OFFICE
350 45.0 55.0147 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
TEAM
350 45.0 55.0148 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
MEDIA
350 45.0 55.0150 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
VTC
350 45.0 55.0151 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
BREAK
350 45.0 55.0150 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
VTC
350 45.0 55.0152 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
PROT
350 45.0 55.0
7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
CHAPL
350 45.0 55.0
7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
CHAPL
TAG LOCATION
SUPPLY COND. (°F)
LVG.ENT.
350 45.0 55.0153 7,502 6,604
SENSIBLE
CAPACITY
(BTUH)
TOTAL
CAPACITY
(BTUH)
COND.
RH
(°F)
75.0 50HIGH
ESP
(IN. WG.)
FAN
SPEED
COND.
55.0 54.0
FCU
CHAPLAIN
WATERENT. AIR LVG. AIR
AIR
(CFM) DB
(°F)
DB
(°F)
WB
350 45.0 55.0154 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
MEDIA
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0160 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
MEDIA
350 45.0 55.0159 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
TEAM
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0175 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
PSY CHT
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0
7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
350 45.0 55.0
7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
ENGINEER
350 45.0 55.0174 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
MEDIA
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
FAN COIL UNIT SCHEDULE
350 45.0 55.0171 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
CHIEF ENG
350 45.0 55.0172 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
ENG NCO
350 45.0 55.0200 7,502 6,604 - 75.0 50HIGH 55.0 54.0
FCU
RAMP
DIV
ENGINEER
DIV
ENGINEER
DIV
CRIMLAW
DIV SJC
CRIMLAW
DIV SJC
CNSL
G0
S
GO
CG
CG
COPS
DIV G8
DIV G8
DIV G8
DIV G8
ENGINEER
DIV
DIV PAO
PUMP REMARKS
MCA V PH. HZMOTOR
(FLA)
ELECTRICAL
0.44 208 1 600.35 185
COOLING COIL
PD
1.5 1.4
FLOW
(GPM)
No. OF
ROWS
FUSE
SIZE
WT.
(LBS)
(PSI)
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
HEAD FLOW
(GPM)(IN.)
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
PUMP
CONDENSATE
REMARKS
MCA V PH. HZMOTOR
(FLA)
ELECTRICAL
0.44 208 1 600.35 185
COOLING COIL
PD
1.5 1.4
FLOW
(GPM)
No. OF
ROWS
FUSE
SIZE
WT.
(LBS)
(PSI)
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
0.44 208 1 600.35 1851.5 1.4- 15
HEAD FLOW
(GPM)(IN.)
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
30 0.1
CHIEF
ASST
TRIAL
CNSL
TRIAL
CNSL
TRIAL
CNSL
TRIAL
CNSL
TRIAL
CNSL
TRIAL
CNSL
TRIAL
CNSL
TRIAL
FCU
FCU
FCU
FCU
FCU
FCU
FCU
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
350 45.0 55.07,502 6,604 - 75.0 50HIGH 55.0 54.0 0.44 208 1 600.35 1851.5 1.4- 1530 0.1
DIV G8
DCSM
DIV G8
DIV G8
DIV G8
DIV G8
DIV G8
CONDENSATE
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173124
M-604
18SB02
H
VA
C S
C H
ED
U
LE
S
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D es ig ne r
Au th or
SHC
he ck er
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
LE
AD
LA
G
OP
DDC SYSTEM POINTS LIST
GR
AP
HI
C
PR
ES
SU
RE
(P
SI
TE
M
PE
RA
TU
RE
F)
SYSTEM POINT DESCRIPTION
SE
T
BA
CK
/S
ET
U P
DE
M
AN
D
LI
M
IT
IN
G
EV
EN
T
PR
OG
RA
M
TI
M
E
SC
HE
DU
LE
OP
T
ST
AR
T/
ST
OP
M
AI
NT
W
OR
K
OR
DE
R
ST
AT
US
O
N/
OF
F
ST
AT
US
O
PE
N/
CL
OS
ED
SE
TP
OI
NT
A
DJ
US
T
W
AT
ER
F
LO
W
(G
PM
KW AI
R
FL
OW
(C
FM
PE
RC
EN
T
RL
A
PE
RC
EN
T
OP
ER
AT
IO
N
CO
(P
PM
DD
C
FI
LT
ER
S
TA
TU
S
OF
F/
ON
HI
GH
A
NA
LO
G
BI
NA
RY
LO
W A
NA
LO
G
CO
M
M . F
AI
L
SE
NS
OR
F
AI
L
DI
AG
NO
ST
IC
S
RE
SE
T
DD
C
RU
N
TI
M
E
AL
AR
M
IN
ST
EX
P
M
ES
SA
GE
NI
GH
T
PU
RG
E
OUTPUT
(EQUIPMENT AND DEVICES ACTUATED, SENSED, AND DISPLAYED BY DDC SYSTEM)
INPUT
ANALOG
OUTPUT INPUT
BINARY SYSTEM FEATURES
ALARMS PROGRAMS
TI
M
ED
O
VE
RR
ID
E
TO
TA
LI
ZI
NG
MOTOR X X X
ROOM THERMOSTAT (AS REQUIRED) X X
SUPPLY / RETURN AIR X X
XX X X X XX
COOLING COIL VALVE X
X X
W
AT
ER
S
EN
SO
R
PA
N
2-
VD
C
CO
NT
RO
L
2-
VD
C
FE
ED
BA
CK
X
ZONE TEMPERATURE X X X
X
X
X
X
MOTOR
SUPPLY / RETURN AIR X
X X
X
XX X X X XX
COOLING COIL VALVE XX
ZONE TEMPERATURE X X X
X
X
X
X
EXHAUST FAN
X X
X
X X X XX
ZONE TEMPERATURE X X X
X
X X
VARIABLE FREQUENCE DRIVE X X XXX
VAV DAMPER X X X X X
COOLING COIL VALVE XX
COOLING TEMPERATURE X X XX
X
X
X
X
X
X
X
X
X
X
X
ELECTRIC POWER METER
WATER METER MAIN SUPPLY X
X X
X
CHILLED WATER MAIN SUPPLY X X
XX X X X XXXXX
X
SUPPLY AIR DISCHARGE PRESSURE X X X
CHILLED WATER - ENTERING
CHILLED WATER - LEAVING
X
X
X
X
FL
OW
F
AI
L
X X X X X X X X X X X X X X X X
CHILLED WATER - ENTERING
CHILLED WATER - LEAVING
X X
X X X X X
REFRIGERANT ALARM X
PUMP MOTOR
PUMP SUCTION
PUMP DISCHARGE
X X X X
X
X X
X
MOTOR X X XX
CHILLER (W/ INTEGRAL PUMP)
VAV TERMINAL (TYP)
DOAS (TYP)
BUILDING
IU/OU - DUCTLESS SPLIT DX (TYP)
FAN COIL UNITS - CEILING CASSETTE (TYP)
AIR HANDLING UNIT - VAV (TYP)
CHILLER SEQUENCE OF OPERATION:
A. DDC SYSTEM SHALL INTERFACE WITH THE CHILLER’S BUILT-IN CONTROLLER
PACKAGE TO PROVIDE THE CONTROL OF THE SYSTEM. ALL CHILLER SAFETIES ARE
TO BE CONTROLLED BY THE CHILLER MANUFACTURER’S CONTROLLER.
B. SYSTEM ENABLE AND LOOP ENABLE:
1. THE DDC SHALL ENERGIZE THE CILLED WATER SYSTEM.
2. THE DDC CAN OVERRIDE THE COMMAND TO NOT START CHILLER IF ONE OR
MORE SYSTEMS HAVE NOT FINISHED/FAILED THE START UP CHECKS.
3. WHEN THIS SYSTEM IS ENABLED AND THE CHILLED WATER PUMPS ARE
PROOFED ON, THE AIR-COOLED CHILLER CONTROL SHALL BE ENABLED.
C. CHILLER CONTROL:
1. THE CHILLER CONTROLLER WILL BE CONNECTED TO THE BUILDING DDC.
2. THE CHILLER CONTROLLER SHALL RUN THE PRIMARY CHILLED WATER
CIRCULATION PUMP. THE CHILLER CONTROLLER SHALL CONTROL THE
PRIMARY/STANDBY OF THE CHILLED WATER PUMPS.
3. WHEN FLOW IS DETECTED, THE CHILLER CONTROLLER SHALL RUN THE
COMPRESSORS.
4. UPON A SIGNAL FROM THE DDC THAT CHILLED WATER IS REQUIRED, THE
CHILLER CONTROLLER WHALL RUN THE CHILLED WATER PUMP. THE CHILLER
CONTROLLER SHALL MODULATE CHILLER CAPACITY AS REQUIRED TO
MAINTAIN LEAVING CHILLED WATER SUPPLY TEMPERATURE SETPOINT OF 44°F.
5. THE CHILLER CONTROLLER SHALL PROVIDE, AT A MINIMUM, THE FOLLOWING:
a. CAPACITY CONTROL BASED ON LEAVING CHOLLED FLUID TEMPERATURE.
b. LIMITING THE CHILLED WATER TEMPERATURE PULLDOWN RATE AT START-
UP.
c. LEAVING CHILLED WATER TEMPERATURE RESET.
d. CHILLED WATER PUP START/STOP CONTROL AND PRIMARY/STANDBY
SEQUENCING TO ENSURE EQUAL PUMP RUN TIME.
ADDITIONAL MONITORING/CONTROL FUNCTIONS SHALL BE PROVIDED
THROUGH THE BACNET CHILLER INTERFACE TO THE DDC SYSTEM.
D. SAFETIES:
1. THE CHILLER WILL RUN WITH THE MANUFACTURER’S BUILT-IN SAFETIES.
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173125
M-605
18SB02
M
EC
H
AN
IC
AL
D D
C
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
SETPOINT SENSOR SCHEDULE
CHILLED WATER SUPPLY 44°F
CHILLED WATER SUPPLY
SUPPLY AIR
RETURN AIR
DUCT STATIC PRESSURE SENSOR (AHU-1)
55°F
55°F
75°F
1.6 IN. WC SP
DUCT STATIC PRESSURE SENSOR (AHU-2) 0.7 IN. WC SP
M-605 NOT TO SCALE
TYPICAL VARIABLE AIR VOLUME AIR HANDLING UNIT (VAV-AHU) CONTROL DIAGRAM
RETURN
AIR
PRIMARY
COOLING
COIL
OUTSIDE AIR
DAMPER FILTER
DPS FILTER
CONTROLLER
CFM FLOW
RING
LOW VELOCITY
DUCT
AIR OUTLET
HIGH VELOCITY
DUCT
NOT TO SCALE
TYP. VAV TERMINAL UNIT CONTROL DIAGRAM
M-605
COMM LINK TO
NEXT DEVICE
COMM LINK FROM
PREVIOUS DEVICE
T TYPICAL
VAV ZONE
SENSOR, 75°F
VFD SD
DAMPER
START/STOP
VFD SPEED
STATUS
SUPPLY AIR
TEMP SENSOR
SMOKE
DETECTORCOOLING
COIL
CHWS
CHWR
CHILLED
WATER
CONTROL
VALVE
TYPICAL
NEW VAV
T
TYPICAL
VAV ZONE
TEMP SENSOR, 75°F
55°F 2/3 DOWN STREAM
PRESSURE SENSOR,
LOCATE ON SUPPLY DUCT
SUPPLY
AIR
DEVICE
COMM LINK
TO NEXT
DEVICE
COMM LINK
FROM PREVIOUS
AHU-X
CONTROLLER
RETURN
AIR TEMP
ALARM
CONTACT TO
FIRE ALARM
SYSTEM
M-605 NOT TO SCALE
TYPICAL FAN COIL UNIT (FCU) CONTROL DIAGRAM
START/STOP
STATUS
SUPPLY AIR
TEMP SENSOR
SMOKE
DETECTOR
PRIMARY
COOLING
COIL
CHWS
CHWR
CHILLED
WATER
CONTROL
VALVE
FROM PREVIOUS
DEVICE
COMM LINK
TO NEXT
DEVICE
COMM LINK
T FCU ZONE
TEMP SENSOR, 75°F
RETURN
AIR
FCU-X
(WHERE REQUIRED)
CONTROLLER
RETURN AIR
TEMP SENSOR
OUTSIDE AIR
TEMP SENSOR
65°F
UV
LIGHT
S UV
SWITCH
PRIMARY
SUPPLY AIR
TEMP SENSOR
CHWR
CHWS
FROM PREVIOUS
DEVICE
COMM LINK
TO NEXT
DEVICE
COMM LINK
STATUS
CONTROLLER
CHWR TEMP
SENSOR
M-605 NOT TO SCALE
TYPICAL DOAS CONTROL DIAGRAM
CHWS FLOW
SENSOR
CHWS TEMP
SENSOR
CHWR TEMP
SENSOR
120VAC
120VAC
FROM
DOAS
(WHERE REQ'D)
CHILLED WATER
CONTROL VALVE
OUTSIDE
AIR TEMP
CHWS TEMP
SENSOR
CHWS FLOW
SENSOR
ALARM
CONTACT TO
FIRE ALARM
SYSTEM
SD
120VAC
M
W
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173126
M-606
18SB02
M
EC
H
AN
IC
AL
D D
C
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
.18
SB
M
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
FCU-6
FCU-5
FCU-56
FCU-53
FCU-3
FCU-2
FCU-13
FCU-11
FCU-25
FCU-27
FCU-29
FCU-31
FCU-17
FCU-16
FCU-26
FCU-28
FCU-30
FCU-24
FCU-20
FCU-22
FCU-59
FCU-23
FCU-18
FCU-15
FCU-21 FCU-19
DOAS-1
DOAS-3
AHU-1
CH-1
2" COND. DRAIN
TERMINATE AT 3" FD
2" COND. DRAIN
TERMINATE AT 3" FD
1/2"
3/4" 1/2"
3/4"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2" 1/2"
1/2"
3/4"
1"
1"
3/4"
3/4"
1 1/4" 1"
1 1/4"
1 1/2"
1 1/4"
1 1/2"
3/4"
1"
1"
2"
1 1/2"
1/2"
3/4"
1"
1 1/2"
2"
1 1/4"
1 1/2"
3/4"
3/4"
3/4"
1"
1"
1"
3/4"
3/4"3/4"
3/4"
IU-1
OU-1
1/2" 1/4"
3/4"
1/2"
1/4"
1 1/4"
1"
3"
3"
2 1/2"
3"
2"
3"
2"
2"
1 1/2"
1 1/2"
1/2"
3/4"
1 1/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
3/4" 1/2"
1/2"
1 1/2"
1 1/4"
1 1/2"
1 1/2"
3" 3"
3"
2"
2"
3"
1 1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
2"
BALL VALVE
(TYP.)
AIR SEPARATOR
(AS-1)
BUTTERFLY
VALVE
(TYP.)
CHEMICAL
POT FEEDER
(CF-1)
CHECK VALVE
2 1/2" CHWS & CHWR
LINES, FOR CONT.
SEE DWG. 1/M-902
2"
1"
2"
2"
2" COND. DRAIN
TERMINATE AT
3" FD
1 1/2"
1"
1" & 1 1/2" COND.
DRAIN TERMINATE
AT 3" FD
FLOW
CONTROL
VALVE
FLOW
CONTROL
VALVE
FLOW CONTROL
VALVE
FLOW
CONTROL
VALVE
FLOW CONTROL
VALVE
FCU-57
FCU-54
FCU-55
FCU-8
3/4"
3/4
1"
3/4"
3/4"
FCU-58
3/4"
3" DIA. CHILLED WATER
SUPPLY & RETURN
PIPING ABOVE GRADE
(7'-10" A.F.F. TO C.L.
OF PIPE)
1/2"
1/4"
2 1/2" GALV. PIPE
SUPPORT, SEE
DETAIL 4/M-504
FCU-14
1/2"
3/4"
1/2"
1/2" 1 1/2"
3/4"
1/2"
FCU-1
FCU-4
FCU-10
FCU-7
FCU-9
3/4"
1/2"
1/2"
3/4"
2"
3/4"
1"
3/4" CO
1 1/4" CO
1"
3/4" CO
1 1/2" CO"
1" CO"
3/4"
1"
3/4"
FCU-12
1"
3/4" CO"
3/4"
3/4"
1 1/4" CO1" CO
2" CO
3/4"
1" CO
3/4" CO
1/2"
1/2"
3/4"1"
3/4"
1"
1"
1 1/4"
1/2"
1"
FLOW
CONTROL
VALVE
1 1/4" 1"
1"3/4"
1"
1"
1 1" CO"
1"
1"
1/2"
3/4" CO
1"
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173127
M-901
18SB02
C H
IL
LE
D W
AT
E R
P
IP
I N G
D I A
G R
A M
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
1 CHILLED WATER PIPING DIAGRAM 1
SB
M
-9
PROFESSIONAL
A
S H
A
SIIA , .U
N
ENGINEER
No. 7624-M
LICENSED
.A
YU
.K H
This work was prepared by me or under my supervision.
FCU-35
FCU-36
FCU-38
FCU-34
FCU-33
FCU-46
FCU-43
FCU-41
FCU-39
FCU-37
FCU-52
FCU-49
FCU-45
FCU-40
FCU-50
FCU-51
FCU-42
FCU-44
FCU-47
FCU-48
FCU-32
DOAS-4
AHU-2
DOAS-2
3/4"
3/4"
3/4"
1"
3/4"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
1"
3/4"3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
2 1/2"
1 1/2"
2"
1 1/2"
1 1/4"
1"
2"
1/4" 1/2"
1/4"
1/2"
1/2"
1/4"
3/4"
2"
1"
1"
1/2"
3/4"
1"
1 1/2"
1 1/2"
1 1/4"
1 1/2"
1"
1"
1"
1"
1"
2"
1 1/2"
1 1/2"
1 1/2"
IU-2
OU-3
2" COND. DRAIN
DN. & TERMINATE
AT 3" FD
1" COND. DRAIN
DN. & TERMINATE
AT 3" FD
1"
1 1/4"
1 1/2"
1"
1"
1 1/2"
2"
2"
1 1/2"
OU-2
OU-3
2 1/2" CHWS & CHWR
LINES, FOR CONT.
SEE DWG. 1/M-901
3/4" COND. DRAIN
DN. & TERMINATE
AT 3" FD
1/2"
1/4"
3/4"
IU-4
OU-4
3/4"
1 1/2"
FLOW CONTROL
VALVE
FLOW CONTROL
VALVE
FLOW
CONTROL
VALVE
1/4"
1/2"
1/4"
1/2"
3/4"
1/4"
1/2"
3/4"
OU-5
3/4"
1/4"1/2"
1/4" 1/2"
1/2" 1/4"
1/4" 1/2"
1/4"
1/2"
1" COND. DRAIN
TERMINATE AT 2" FD
1 1/4" CO
1 1/4"
3/4"
3/4"
1 1/4"
2" CO"
1 1/2" CO
1" CO
3/4"
1 1/4" COND. DRAIN
TERMINATE AT 2" FD
1" CO
OU-5
1/4"
1/2"
1/2"
3/4"
3/4"
US Army Corps of Engineers ®
SHEET OF
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
173128
M-902
18SB02
C H
IL
LE
D W
AT
E R
P
IP
I N G
D I A
G R
A M
U
LR
IC
H
W
AY
SC
H O
FI
EL
D B
AR
R
AC
KS
, O
AH
U , H
I H
O N
O L U
LU
D
IS
TR
IC
T
F O R
T
SH
AF
TE
R , H
AW
AI
I
M C
E
IN
TE
R
N
AT
IO
N
AL
, I
N C
S
. B
ER
ET
AN
IA
S
TR
EE
T
ST
E
H
O N
O
LU
LU
, H
AW
AI
I 9
D N
JA SHD
N
M
AY
. W
A-
-D
-0
SHFI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
RTA SUBMITTAL, DBB, 7 MAY 2018
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
1 CHILLED WATER PIPING DIAGRAM 2
SB
M
-9
GENERAL NOTES:
ELECTRICAL SYMBOLS
DESCRIPTIONNEWEXST
JUNCTION BOX IN CEILING
EXPOSED CONDUIT WITH WIRES
ELECTRIC PANEL, +6"-0" TO TOP
LIGHT SWITCH, 1-POLE, +45" AFF
LIGHT SWITCH, 3-WAY, +45" AFF
JUNCTION BOX WALL MOUNTED
S
S
S
AFF
GFCI
RCPT
WP
DUPLEX RCPT, NEMA 6-20R, +18" (+6" ABOVE COUNTER)
DOUBLE DUPLEX RCPT, NEMA 5-20R, +18" (+6" ABOVE COUNTER)
SINGLE RCPT, NEMA 5-20R OR AS INDICATED, +18" OR AS INDICATED
DUPLEX RCPT, NEMA 5-20R, GFCI, +36" OR AS INDICATED (+6" ABOVE COUNTER)
POWER POLE
MOTOR CONNECTION
MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION
MAGNETIC MOTOR STARTER, HP-RATED
DISCONNECT SWITCH, HP-RATED
RACEWAY WITH WIRES CONCEALED IN WALL OR CEILING (3 WIRES INDICATED, GROUND WIRE NOT SHOWN)
UNDERGROUND RACEWAY WITH WIRES
FLEXIBLE CONDUIT WITH WIRES
LIGHT FIXTURE TYPE INDICATOR, TYPE "A" INDICATED
ABOVE FINISH FLOOR
GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE
WEATHERPROOF
S OCCUPANCY SENSOR, WALL MOUNTED, +45"
OCCUPANCY SENSOR, CEILING MOUNTED
2'X4' LED CEILING RECESSED INDIRECT/DIRECT LIGHT
2'X2' LED CEILING RECESSED INDIRECT/DIRECT LIGHT
1'X4' LED CEILING SURFACE INDIRECT/DIRECT LIGHT
FLOOR OUTLET, DUPLEX RCPT, NEMA 5-20R
3.
2.
1.
4.
5.
6.
7.
9.
10.
11.
12.
13.
14.
8.
VAV CONNECTION
FLOOR OUTLET, DOUBLE DUPLEX RCPT, NEMA 5-20R
LIGHT LEVEL SENSOR
MANUAL DIMMER SWITCH, +45" AFFS
2'X2' LED CEILING RECESSED INDIRECT/DIRECT LIGHT W/INTEGRAL BATTERY PACK
15.
TIME SWITCH
2'X4' LED CEILING RECESSED INDIRECT/DIRECT W/ INTERGRAL BATTERY PACK
COMPLY WITH NEC, UFC 3-520-01, UFC 3-530-01, UFC 3-550-01, AND REQUIREMENTS OF NFPA 101.
EXISTING CONDITION BASED ON LIMITED FIELD OBSERVATION AND REFERENCE DRAWINGS.
CONTRACTOR TO VERIFY EXISTING CONDITION AND REPORT DISCREPANCY TO ENGINEER
PRIOR TO CONSTRUCTION.
SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHT FIXTURES.
SEE ARCHITECTURAL PLANS, INTERIOR ELEVATIONS & DETAILS, SHOP DRAWINGS & EQUIPMENT
BROCHURES FOR ELECTRICAL REQUIREMENTS & PROVIDE WIRING AS APPROPRIATE. VERIFY &
COORDINATE EQUIPMENT RATINGS, MOUNTING HEIGHTS, AND EQUIPMENT RACEWAY ROUGH-IN
REQUIREMENTS.
VERIFY & COORDINATE REQUIREMENTS FOR MECHANICAL EQUIPMENT WITH MECHANICAL
CONTRACTOR. SEE MECHANICAL PLANS.
FOR INSTALLATION OF ALL ELECTRICAL EQUIPMENT, COORDINATE ALL WORK WITH OTHER TRADES TO AVOID CONFLICTS AND PROVIDE A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM WITHIN
INTENT INDICATED IN DRAWINGS AND SPECIFICCATIONS.
ALL RACEWAYS SHALL BE INSTALLED CONCEALED WHERE POSSIBLE. IF EXPOSED, ROUTE NEATLY AND INCONSPICUOUSLY ALONG CORNERS, STRUCTURAL MEMBERS AND ARCHITECTURAL TRIMS FOR
MINIMUM PROFILES. ALL NEW EXPOSED RACEWAYS SHALL BE GALVANIZED RIGID STEEL (GRS)
UNLESS INDICATED OTHERWISE. ELECTRICAL METALLIC TUBING (EMT) WITH COMPRESSION FITTINGS
MAY BE USED WITHIN BUILDING INTERIORS CONCEALED IN WALLS & CEILING SPACES.
ALL OUTDOOR EQUIPMENT SHALL BE NEMA 4X STAINLESS STEEL UNLESS OTHERWISE NOTED.
EXPOSED SMALL JUNCTION BOXES SHALL BE CAST METAL TYPE WITH NO UNUSED FACTORY
KNOCK-OUTS. OUTLET BOXES SHALL MATCH ELECTRICAL DEVICES AND COMPLY WITH
MANUFACTURER'S RECOMMENDATIONS.
PAINT ALL EXPOSED RACEWAYS AND BOXES WITH TWO COATS METAL PRIMER AND
TWO COATS POLYURETHANE ENAMEL FINISH TO MATCH SURROUNDING SURFACES.
ADJUST LOCATION OF THE NEW ELECTRICAL EQUIPMENT AND WIRING AS REQUIRED TO CLEAR
BUILDING OBSTRUCTIONS & EQUIPMENT. PROVIDE ANY SPACERS, FILLERS, BRACKETS, HANGERS, ETC. NEEDED TO PROPERLY INSTALL THE ELECTRICAL EQUIPMENT AND WIRING.
REPAIR ANY DAMAGE MADE TO THE BUILDING AND UTILITIES INCLUDING EXISTING CEILINGS, WALLS, FLOORS, OTHER STRUCTURES AND UTILITY LINES CAUSED DURING CONSTRUCTION.
CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, SERVICES, AND EQUIPMENT NECESSARY FOR THE
PROPER REMOVAL, TRANSPORTATION, AND DISPOSAL OFFSITE OF PCB CONTAINING LIGHTING
BALLASTS, ASSOCIATED MERCURY-CONTAINING FLUORESCENT LAMPS, IN ACCORDANCE WITH EPA AND OSHA REQUIREMENTS, AND ALL LOCAL, STATE, AND FEDERAL REGULATIONS. DO NOT BREAK MERCURY CONTAINING FLUORESCENT LAMPS. DISPOSE OF REMOVED MATERIALS OFF GOVERNMENT
PROPERTY IN ACCORDANCE WITH EPA AND LOCAL REGULATIONS AT A PERMITTED SITE.
SEAL ALL PENETRATIONS THROUGH FIRE RATED WALL AND SLABS USING U.L. LISTED FIRE
RATED SEALANT TO MAINTAIN THE INTEGRITY OF THE FIRE RATING.
DO NOT MOUNT WALL OUTLETS BACK TO BACK.
T
D
V
U
A
J
M
J
1'X4' LED CEILING SURFACE INDIRECT/DIRECT LIGHT W/ INTEGRAL BATTERY PACK
LED RECESSED DOWNLIGHT
LED WALL LIGHT
EXIT SIGN
CEILING OUTLET, DUPLEX RCPT, NEMA 5-20R
RACEWAY WITH WIRES CONCEALED BELOW FINISH FLOOR
JUNCTION BOX/FLEXIBLE CONNECTION FOR WIRED SYSTEM FURNITURE COORDINATE W/ WIRED SYSTEM J
FURNITURE SUPPLIER/MANUFACTURER
16. CONTRACTOR TO SUBMIT A COMPUTERIZED FOOTCANDLE LEVEL PRINTOUT FOR EGRESS PATHS AND
EMERGENCY LIGHTING SHOWING COMPLIANCE WITH THE REQUIREMENTS OF NFPA 101-7.8,9.
17. PROVIDE MULTIPLE HANDLE TIES IN PANELBOARDS FOR ASSOCIATED CIRCUIT BREAKERS USED ON
MULTIWIRE BRANCH CIRCUITS WITH SHARED NEUTRAL PER UFC 3-520-01.
M
J e
US Army Corps of Engineers ®
SHEET OF 173
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D…