ALL EXPOSED CONDUITS SHALL BE GRC (GALVANIZED RIGID METALLIC

CONDUIT). ALL CONCEALED CONDUITS SHALL BE EMT (ELECTRICAL

METALLIC TUBING). ALL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE

40 UNLESS NOTED.

12.

7. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH

THE CONTRACT DOCUMENTS. TESTING SHALL BE DONE IN ACCORDANCE

WITH THE CONTRACT DOCUMENTS.

ALL ELECTRICAL SPLICES BELOW GRADE SHALL BE WATERPROOF.

11.

REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION RESULTING FROM THE

INSTALLATION OF ELECTRICAL ITEMS. THE AREAS REPAIRED SHALL MATCH

THE ADJACENT SURFACES IN TEXTURE AND COLOR.

10.

3. THE CONTRACTOR SHALL FURNISH ALL EQUIPMENT FOR TEMPORARY

CONSTRUCTION POWER AS REQUIRED.

FIRE ALARM/MASS NOTIFICATION SYSTEM GENERAL NOTES:

SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK, THE CONTRACTOR

SHALL MARK SUCH CHANGES ON THE AS-BUILT DRAWINGS. IF THESE CHANGES REQUIRE

ALTERNATE METHODS TO THOSE SPECIFIED IN THE CONTRACT DOCUMENTS, THE

CONTRACTOR SHALL SUBMIT DRAWINGS SHOWING THE PROPOSED ALTERNATE METHODS

TO THE CONTRACTING OFFICER. THE CONTRACTOR SHALL NOT PROCEED UNTIL

APPROVAL IS OBTAINED FROM THE CONTRACTING OFFICER. REARRANGEMENT OF WORK

FOR THE PURPOSE OF COORDINATION SHALL NOT BE CONSIDERED AN ITEM FOR EXTRA

COST.

THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CONTRACTING OFFICER

BEFORE MAKING ANY PENETRATIONS THROUGH STRUCTURAL MEMBERS OR

FIRE RATED WALLS AND SLABS.

ALL PENETRATIONS THROUGH FIRE BARRIERS SHALL BE FIRE STOPPED TO

MAINTAIN THE INTEGRITY OF THE FIRE BARRIER. FIRE STOPPING MATERIAL

SHALL BE U.L. LISTED.

THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL JUNCTION AND PULL

BOXES REQUIRED FOR THE INSTALLATION OF ELECTRICAL DEVICES AND

EQUIPMENT, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS.

SIZING OF THESE BOXES SHALL BE PER THE NATIONAL ELECTRICAL CODE.

6.

4.

2.

5.

8.

ALL EQUIPMENT SHALL BE CAPABLE OF FITTING IN THE SPACES LOCATED WHILE

MEETING THE MANUFACTURER'S RECOMMENDED ACCESS REQUIREMENTS. REVIEW

ALL PLACES WHERE EQUIPMENT IS TO BE INSTALLED PRIOR TO ORDERING OF

EQUIPMENT AND NOTIFY THE CONTRACTING OFFICER OF ANY INADEQUATE

CLEARANCES OR CONDITIONS THAT WILL PREVENT THE PROPER INSTALLATION,

MAINTENANCE, AND OPERATIONS OF THE EQUIPMENT.

PROVIDE ACCESS PANELS TO ALL CONCEALED TRANSFORMERS, DEVICES,

JUNCTION BOXES AND EQUIPMENT. COORDINATE THE LOCATION OF ACCESS

PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.

PROVIDE BLANK COVER PLATES FOR EXPOSED RECESSED JUNCTION

BOXES AFTER REMOVAL OF ITEM NOT BEING REPLACED WITH NEW.

ALL EQUIPMENT, MATERIAL, DEVICE AND WIRING LOCATED

OUTDOORS SHALL BE RATED FOR WET CONDITIONS.

14.

15.

THE CONTRACTOR SHALL COMPLY WITH THE CONSTRUCTION PRACTICES

AND REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRIC

CODE (NFPA 70), NATIONAL ELECTRICAL SAFETY CODE, AMERICAN

ELECTRICIANS HANDBOOK BY CROFT EDISON ELECTRIC INSTITUTE,

APPLICABLE INSTRUCTIONS OF MANUFACTURERS OF EQUIPMENT AND

MATERIALS SUPPLIED FOR THE PROJECT.

1.

9.

ALL WIRING SHALL BE CONCEALED UNLESS OTHERWISE NOTED IN

FINISHED AREAS. CUT AND PATCH EXISTING WALLS AND CEILINGS AS

REQUIRED FOR NEW CONCEALED CONDUIT INSTALLATION.

FIRE ALARM/MASS NOTIFICATION SYSTEM NOTES:

1.

7.

6.

5.

4.

10.

11.

12.

13.

3.

8.

9.

COORDINATE THE EXACT DEVICE LOCATIONS WITH ELECTRICAL AND MECHANICAL

SYSTEM EQUIPMENT AND BUILDING ARCHITECTURAL FEATURES. COORDINATE

FIRE ALARM DEVICES WITH FURNITURE PARTITION LOCATIONS TO ENSURE

DEVICES ARE NOT OBSTRUCTED.

MINIMUM CONDUIT SIZE SHALL BE 3/4"

MINIMUM CIRCUIT PERFORMANCE REQUIREMENTS:

IDC - INITIATING DEVICE CIRCUIT SHALL BE CLASS A

NAC - NOTIFICATION APPLICATION CIRCUIT SHALL BE CLASS A

SLC - SIGNALING LINE CIRCUIT SHALL BE CLASS A

ALL LOOPS SHALL HAVE OUTGOING AND RETURN CONDUCTORS IN SEPARATE

CONDUIT.

CLASS A CIRCUITS SHALL BE INSTALLED SUCH THAT THE OUTGOING AND

RETURN CONDUCTORS ARE SEPARATED 1 FOOT WHERE THE CABLE IS

INSTALLED VERTICALLY AND 4 FEET WHERE THE CABLE IS INSTALLED

HORIZONTALLY. THE OUT GOING AND RETURN CIRCUIT CONDUCTORS ARE

PERMITTED TO BE INSTALLED IN THE SAME CONDUIT FOR A MAXIMUM

DISTANCE OF 10 FEET WHERE THE OUTGOING AND RETURN CONDUCTORS

ENTER OR EXIT THE DEVICE.

"T" TAPPING OF ANY CLASS "A" CIRCUIT IS PROHIBITED.

UPON COMPLETION OF THE INSTALLATION OR ALTERATION, A SATISFACTORY

TEST OF THE ENTIRE SYSTEM SHALL BE MADE IN THE PRESENCE OF THE

CONTRACTING OFFICER REPRESENTATIVE AND FEDERAL FIRE INSPECTOR. ALL

FUNCTIONS OF THE SYSTEM SHALL BE TESTED.

PROVIDE BOOSTER PANELS AS REQUIRED FOR A COMPLETE SYSTEM.

PROVIDE DETECTION (SMOKE DETECTOR) AT ALL PANELS & POWER

EXTENDER PANELS.

ALL EXTERIOR DEVICES SHALL BE WEATHERPROOFED & ALL DEVICES LOCATED

IN WET LOCATIONS SUCH AS SHOWERS SHALL BE WEATHERPROOF TYPE.

MANUAL ACTIVATION DEVICE

(PULL STATION)

AUDIO DEVICEVISUAL OR

COMBINED

AUDIO/VISUAL

DEVICE

MOUNTING/INSTALLATION REQUIREMENTS

ALL CONNECTIONS FOR IDC, NAC, AND SLC CONDUCTORS TO BE MADE USING

SCREWED TERMINAL BLOCKS. (WIRE NUTS ARE PROHIBITED)

"6

K E

Y P

A D

A T

FIRE ALARM

CONTROL

PANEL/MASS

NOTIFICATION

PANEL

B O

T T

O M

O F

D E

V

IC

E

B O

T T

O M

O F

D E

V

IC

E

H A

N D

L E

T O

H A

N D

L E

CLASS A OUTGOING AND RETURN CONDUCTORS TO BE

SEPARATED A MINIMUM OF 12" WHERE THE CABLE IS INSTALLED

VERTICALLY AND 48" WHERE THE CABLE IS INSTALLED

HORIZONTALLY. THE OUTGOING AND RETURN CIRCUIT CONDUCTS

ARE PERMITTED TO BE INSTALLED IN THE SAME CONDUIT FOR A

MAXIMUM DISTANCE OF 10 FEET WHERE THE OUTGOING AND

RETURN CONDUCTS ENTER OR EXIT THE DEVICE

OUTGOING AND RETURN WIRING ARE

NOT PERMITTED TO BE INSTALLED IN

A SINGLE CONDUIT.

14. MASS NOTIFICATION STROBES SHALL BE MARKED "ALERT" AND BE

AMBER IN COLOR.

ALL AUDIBLE AND VISUAL APPLIANCES SHALL BE SYNCHRONIZED AND

PROVIDE THE STANDARD TEMPORAL PATTERN PER NFPA 72.

FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL COMPLY WITH NFPA 70, NFPA 72,

NFPA 90A, ADAAG, ABA, UFAS AND SPECIFICATIONS. PROVIDE A SUPERVISED,

COMBINED AUDIO, FIRE, AND EMERGENCY EVACUATION SYSTEM.

EXTERIOR AUDIBLE DEVICES SHALL MEET THE PUBLIC MODE

AUDIBILITY REQUIREMENTS PER NFPA 72.

15. DUCT DETECTOR SHALL BE COMPATIBLE WITH THE FIRE ALARM SYSTEM.

1" WITH TYPE II COAXIAL CABLE

LIGHTNING ARRESTOR STATIC

DISCHARGE UNIT W/ ENCLOSURE

WALL MOUNTS

1" F/F PULLING ELBOW

BUILDING TRANSCEIVER

ANTENNA CUT TO FREQUENCY BY INSTALLER

16. STROBES SHALL FLASH AT A MINIMUM OF 15 CANDELA UNLESS NOTED OTHERWISE.

FACP/

MNP

THE NUMBER OF DEVICES SHOWN ARE CONCEPTUAL . THE FIRE ALARM SYSTEM

SHOWN IS MINIMUM REQUIRED AND THE FINAL QUANTITY SHALL BE IN ACCORDANCE

WITH THE APPLICABLE CODE, SPECIFICATIONS AND MANUFACTURER'S EQUIPMENT

LISTING. SHOP SUBMITTAL TO SHOW DETAILED DEVICE LOCATIONS IN ACCORDANCE

WITH THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS AND WIRE COUNT.

2.

THE NUMBER OF DEVICES SHOWN ARE CONCEPTUAL . THE FIRE ALARM SYSTEM

SHOWN IS MINIMUM REQUIRED AND THE FINAL QUANTITY SHALL BE IN ACCORDANCE

WITH THE APPLICABLE CODE, SPECIFICATIONS AND MANUFACTURER'S EQUIPMENT

LISTING. SHOP SUBMITTAL TO SHOW DETAILED DEVICE LOCATIONS IN ACCORDANCE

WITH THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS AND WIRE COUNT.

16.

POWDER ACTUATED FASTENERS, SHOT PINS, AND EXPANSION BOLTS LESS THAN 1/2"

IN DIAMETER SHALL NOT BE PERMITTED IN EXISTING PRECAST CONCRETE ROOF

MEMBERS SUCH AS INVERTED T-GRIDERS, RECTANGULAR BEAMS, AND WEB OR STEM

PORTIONS OF DOUBLE T-GRIDERS. SEE ROOF FRAMING PLANS ON STRUCTURAL

DRAWINGS.

17.

17. ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS, WHEN

PROVIDED MUST BE FACTORY PAINTED RED IN UNFINISHED AREAS (E.G.,

ABOVE CEILINGS, MECHANICAL ROOMS, ETC.)

18. ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS, WHEN

PROVIDED ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM

FINISHING IN FINISHED AREAS. THE INSIDE COVER OF THE JUNCTION

BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST

HAVE PAINTED RED BANDS 3/4" (20 MM) WIDE AT 20 FEET (6M) INTERVALS

AND ON BOTH SIDES OF ALL FLOOR, WALL, AND CEILING PENETRATIONS.

THE PROJECT AND SPECIFICATIONS SHALL REFERENCE THE USAC ENGINEERING

MANUAL (EM), EM-385-1-1 AND NFPA 241, 2013 EDITION AND SHALL FOLLOW THE

REQUIREMENT OF THE INSTALLATION'S FIRE REGULATIONS.

18.

THE CONSTRUCTION (SHOP) DRAWINGS AND CALCULATIONS MUST BE PREPARED BY,

OR PREPARED UNDER THE IMMEDIATE SUPERVISION OF THE QFPE. THE QFPE MUST

AFFIX THEIR PROFESSIONAL ENGINEERING STAMP WITH SIGNATURE TO THE SHOP

DRAWINGS, CALCULATIONS AND MATERIAL DATA SHEETS, INDICATING APPROVAL

PRIOR TO SUBMITTING THE FIRE ALARM SYSTEM SHOP DRAWINGS TO THE DFPE. THE

QFPE MUST MONITOR THE INSTALLATION OF THE FIRE PROTECTION SYSTEMS AND

CERTIFY IN WRITING THAT THE FIRE PROTECTION SYSTEMS HAVE BEEN

CONSTRUCTED AND OPERATE AS INTENDED IN THE DESIGN PLANS AND

SPECIFICATIONS.

19.

THE FIRE ALARM TRANSMITTER SHALL BE MONACO AND THE MASS NOTIFICATION

TRANSCEIVER IS COOPER WAVES 8.

20.

FIRE ALARM/MASS NOTIFICATION PANELFMCP

WP WEATHER PROOF

ADDRESSABLE MONITOR MODULEM

FEP

FIP FIRE ALARM RADIO TRANSCEIVER INTERFACE PANEL

EXIST

SYMBOLS

NEW

DESCRIPTION

MANUAL PULLSTATION

RADIO TRANSCEIVER ANTENNA (SEPARATE FOR MASS AND FIRE ALARM)

FIRE ALARM/MASS NOTIFICATION LEGEND

FIRE ALARM POWER EXTENDER PANEL

PS PRESSURE SWITCH

M

WALL MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER

TAMPER SWITCH

FLOW SWITCH

SMOKE DETECTOR, PHOTOELECTRIC

LOCAL OPERATOR'S CONSOLELOC

MASS NOTIFICATION POWER EXTENDER PANELMEP

RAP REMOTE AMPLIFIER PANEL

EMERGENCY HVAC SHUTDOWN SWITCH

F

CEILING MOUNTED MASS NOTIFICATION STROBE WITH AMBER LENSE MARKED "ALERT"

WITH CANDELA RATING NOTED

CEILING MOUNTED FIRE ALARM STROBE WITH CLEAR LENSE MARKED "ALERT"

WITH CANDELA RATING NOTED

XX

XX

CEILING MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE WITH CLEAR

LENSE MARKED "ALERT" WITH CANDELA RATING NOTED

XX

WALL MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE WITH CLEAR

LENSE MARKED "ALERT" WITH CANDELA RATING NOTED

MASS NOTIFICATION TRANSCEIVERTRX

PHOTOELECTRIC DUCT SMOKE DETECTOR

XX

C

CEILING MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER

C

P

P

P

SURGE SUPPRESSIONTV

FIRE ALARM/MASS NOTIFICATION ANNUNCIATORANN

HS

MM

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H

I

18SB02

OF 173

FA001

F

IR

E A

L A

R M

N O

T E

S A

N D

L E

G E

N D

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

A

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

GENERAL NOTES:

1. CONTRACTOR TO FIELD VERIFY LOCATION OF THE

EXISTING DEVICES AND COMPONENTS.

DEMOLISH ALL EXIST.

FIRE ALARM DEVICES,

PANELS, CONDUITS,

AND COMPONENTS IN

BLDG. 2091

WOMENS

7A

MEN'S

7B

ADCO

CORRIDOR

CLASSROOM

131WAITING

CIVILIAN

ACPL

CPC

STOR

STOR

17A

STOR

COMPUTER RM

INSTRUCTOR

CONTRACT

COORDINATOR

PREVENTION

CORRIDOR

PREVENTION

ASSISTANT

BREAK ROOM

WAITING

MILITARY

TESTING

CIVILIANTOILET

AIBTC

STAFF

COFFEE AREA

FTDTL

BOOTH

TOILET

TOILET

STORAGE

SECURED

STORAGE

STORAGE

STAFF

TOILET

STAFF

JAN

ELECT

LUNCH ROOM

PROGRAM

OFFICE

14B

OFFICE

14A

CLASSROOM #2

ACS

CLASSROOM #1

ACS

PROGRAM

LC STORAGE

19D

LC STORAGE

19E

LC STORAGE

19C

CLOSET

LENDING

CLOSET

19A

LENDING

LC STORAGE

19B

IVC

READINESS

FINANCIAL

ACS

6A

CHIEF

OFFICE

16R

OFFICE

OFFICE

LOBBY

STORAGE

AER FILES

16F

CORRIDOR

4A

CORRIDOR

PROGRAM

ADVOCACY

FAMILY

PROGRAM

ADVOCACY

FAMILY

READINESS

STORAGE

I&R FILES

MGR

I&R

BREAK

2A

COMM

16S

OFFICE

8A

STORAGE

133A

COMM

11E

TOILET

11D

OFFICE

11A

OFFICE

11B

OFFICE

11C

STOR

11F

HALL

11J

FAMILY

STOR

11G

CORRIDOR

4B

CORRIDOR

OFFICE

8E

OFFICE

8D

OFFICE

8C

JAN

7C

ELECT

8B

OFFICE

9A

OFFICE

9B

STOR

11H

MEMBER

FAMILY

EXCEPTIONAL

OFFICE

16A

OFFICE

16B

OFFICE

16C

OFFICE

16D

OFFICE

16E

STORAGE

17B

A A

B

C

D

E

F

B

C

D

E

F

2 3 4 5 6 7 8

3 4 5 6 7 8 9 10 11

2322212019181716

20191817161514

UP

U P

DNDN

DN

DN

D N

DN

DN

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H I

18SB02

OF 173

FD101

F

IR

E A

L A

R M

D E

M O

L

IT

IO

N

P L A

N

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

3/32" = 1'-0"A1

FIRE ALARM DEMOLITION PLAN

S E

C O

N D

T

IT

L E

S

B F

D

E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

REF.

W

W P P

P2 W

W P

P

P

W

W P

2WWP

L O

C

A N

N

P

2W WP

FEP

MEP

FMCP TRX FIP

P

W

W P

W

W P

P

30 2W

2W WP

2WWP

P

RAP FTR

DN

UP

DN

DN

DN

DN

REF.

W

W P P

P2 W

W P

P

P

W

W P

2WWP

L O

C

A N

N

P

2W WP

FEP

MEP

FMCP TRX FIP

P

W

W P

W

W P

P

30 2W

2W WP

2WWP

P

RAP FTR

AA

BB

CC

DD

EE

FF

M

30 1/2W

C

M

30 1/2W

C

M

C M

1/2W

75 1/2W

C 75

M

75 1/2W

C 75

M

1/2W

C

75 1/2W

C 75

M

75 1/2W

C 75

M

75 1/2W

C 75

M

75 1/2W

C 75

M

75 1/2W

C 75

M

75 1/2W

C

75M

2W

M

2W

M

30 1/2W

C 30

M

C

1/2W

M

C

1/2W

M

1W

75 1/2W

C WP

75WP

M

30 1/2W

C

M

30 1/2W

C 30

M

C

1/2W

75 1/2W

C WP

75WP

M

30 1/2W

C WP

30WP

M

15 1/2W

C 15M

1/2W

C 30 M

2W

M P

M

30 1/2W

C 2W

M 75

30 1/2W

C 30

M

30 1/2W

C

30M

C 1/2W

M

15 1/2W

C 15

M

1/2W

C

M

1/2W

C

75 1/2W

C

75M

30 1/2W

C 30

M

75 1/2W

C

75M

75 1/2W

C

1/2W

C

75 1/2W

M

75C

75 1/2W

M

75C

75 1/2W

M

75C

75 1/2W

M

75C

30 1/2W

C

30M

30 1/2W

C

30M

75 1/2W

C 75

M

75 1/2W

C 75

M 30 1/2W

C

30M

HS 75 1/2W

M

75C

30 1/2W

C 30 M

30 1/2W

C 30

M

30 1/2W

M

30 1/2W

C 30 M

30 1/2W

M

30 1/2W

M

30 1/2W

M

C

C

C F 15

M 15

75 1/2W

C

M

75 1/2W

C

M

30 1/2W

C

30M

1/2W

C

1/2W

C

75 1/2W

C 75

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C M 3015

1/2WC

M 15

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

P

15 1/2W

C

M

15 1/2W

C

M

1/2W

C

1/2W

C

15 1/2W

C

M

1/2W

C

15 1/2W

C

M

15 1/2W

C

M

1/2W

C

1W

M

P

M

1W

M

1/2W

15 1/2W

C

M

30 1/2W

C

30M

30 1/2W

C

30M

30 1/2W

C

M

1/2W

M

C

C

30 1/2W

C 30

M

15 1/2W C

15M

30 M

1/2W

30 1/2W

C 30

M

30 1/2W

C 30

M

15WP

15WP

F

M

MWP

1/2WWP

MWP

1/2WWP

15WP

15WP

F

M

30 1/2W

C 30

M

30 1/2W

C

30M

30 1/2W

C

30M

30 1/2W

C

30M

30 1/2W

C

30M

30 1/2W

C

30M 75 1/2W

C

75M

WP

WP

75 1/2W

C

75M

WP

WP

15WP

M

WP F

15WP

F

WP M

1/2W

C 30

M

1/2W

C

M 1/2W

C

1/2W

C

M

C 1/2W

M

P

30 1/2W

C

30M

75 1/2W

C

75M

75 1/2W

C 75

M

1/2W

M

C

1/2W

M

75C

1/2W

C

M

1/2W

C

M

1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

30 1/2W

C

M

M

1/2W15

CM

1/2W15

C

1/2W

C

M

30 1/2W

C

30M

30 1/2W

C

30M

M

M

1/2W30

C

C

1/2W

M

C

1/2W

M

C 1/2W

M

30 1/2W

C

M

30 1/2W

C

M

75 1/2W

C

M

75 1/2W

C

M

30 1/2W

C

M

C

1/2W

M

75 1/2W

C

M

75 1/2W

C

M

75 M

1W

30 1/2W

C 30

M

75M

WP WP

M

AIM

AIM AIM

AIM

AIM

PS

AIM

P

AOM

AIM

P

AOM

1/2W

C

1/2W

C

1/2W

C

75 1/2W

C 75

M 1/2W

C

75 1/2W

C

M

1/2W

C

75 1/2W

C 75

M 1/2W

C

75 1/2W

C

1/2W

C

75 1/2W

C M

M

1/2W

C

C 1/2W

M

AIM

AOM

AIM

AOM

AIM

AOM

AIM

AOM

AIM

AOM

AIM

AOM

AIM

AOM

AIM

AOM

AA

BB

CC

DD

EE

FF

LOBBY

FIRE ALARM &

SPKR

SECURITY

CORR

SIPRNET

TEAM

MEDIA

SCA

CBRN NCO

CBRN SGM

CBRN OFF

OIC

NCOIC

MECH

M SHOWER

MEN RESROOM

WOMEN

RESROOM

CORR

DIV PAO

OFFICE

TEAM

MEDIA

PA OFF

VTC

BREAK

PROT

CHAPLAIN

MEDIA

CHIEF CHAPL

ASST CHAPL

CORR

TEAM

MEDIA

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

MECH

CHIEF ENG

ENG NCO

TR

MEDIA

PSY CHT

CORR

DIV SURGEON

PSYCHT

SURGOEN

MEDIA

TEAM

CH MED OPS

MED OPS

MECH

DIV RETENSION

TEAM

MEDIA

CNSLR

CNSLR

SR CNSLR

MR2 CNSLR

TR

ELECT

JAN

WOMEN

RESROOM

MEN RESTROOM

WOMEN SHOWER

MEN SHOWER

PROVIDE FIRE ALARM/MASS NOTIFICATION

SYSTEM IN ACCORDANCE WITH NEFA 72,

UFC 3-600-01, UFC 4-021-01, AND NFPA 101

MASS NOTIFICATION

ANTENNA

FIRE ALARM ANTENNA

TAMPER SWITCHES AND

PRESSURE SWITCH LOCATED IN

THE FIRE SPRINKLER ROOM

FOR LOCATION OF CIRCUIT BREAKER # AND

PANEL NAME SEE SHEET FA601. FOR PANEL

LOCATION SEE ELECTRICAL SHEET

DIV G8

CG

COFS

DCSM

M

S

GO

ELECT

124 JAN

WOMEN

RESROOM

MEN RESROOM

M SHOWER

SPCL STAFF

DIV CBRNE

105 CMD CNSLR

TRIAL CNSL

DIV SJC-CRIMLAW

Room

RAMP

MCP-OD

DIV SAFTY

MECH

TR

SUPRVSR

MEDIA

THE FIRE ALARM SPEAKER

INSIDE THE LOBBY SHALL DE-

ACTIVATE UPON ACTIVATION OF

THE MICROPHONE ONLY IN THE

LOBBY AREA.

THE FIRE ALARM SPEAKERS

INSIDE THE FIRE ALARM ROOM

SHALL DE-ACTIVATE UPON

ACTIVATION OF THE

MICROPHONE ONLY IN THE FIRE

ALARM ROOM AREA.

THE FIRE ALARM SPEAKERS

INSIDE THE FIRE ALARM ROOM

SHALL DE-ACTIVATE UPON

ACTIVATION OF THE

MICROPHONE ONLY IN THE FIRE

ALARM ROOM AREA.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H I

18SB02

OF 173

FA101

F

IR

E A

L A

R M

N E

W W

O R

K P

L A

N

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

3/32" = 1'-0"A1

FIRE ALARM NEW WORK PLAN

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M M

M

M

M M

M

M

M

F

M

F

F

F

F

F

F

M

F

F

F

F

M F

M F

F

F M

F

M

F

F

F

F

F

F

M

M

F

F

M

F

F M

F

F

F

F

F

M

F

F

F M

F

F F

F

F

F

F F

F

F

M

F

F

F

F

M

F

F

F

F

F

F

F

F

F

F

F

F

F

F M

F

F

F

F

F

F

F

F

F

F

M

F

F

F F

F

F

M

F

F

F

F

FF

F

F

M

F

F

F

F

MF

F

F

F

F

F

F M

F F

M F

F

F M

F

F

F

F

F

F

F

F

F S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

FS

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

SS

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

SS

S

S

SS

S

S

S

S

S

S

S

S

S

S

SS

S

S

S

S S S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S SS

S

S

S

S

S

S

S

S

M

M

M

MM

M

F

F

F

F

F

F

F

FIRE ALARM NOTES:

1. PROVIDE INPUT AND OUTPUT MODULES FOR THE

FIRE SMOKE DAMPERS FOR EACH JANITOR'S

CLOSETS, EACH ELECTRICAL ROOMS, EACH MECHANICAL

ROOMS. SEE MECHANICAL DRAWINGS FOR THE LOCATIONS

OF SMOKE DAMPERS. (TOTAL OF 8)

2. PROVIDE DUCT DECTECTORS FOR AHU OVER 2000 CFM,

REFER TO MECHANICAL DRAIWNGS FOR AHU LOCATION.

(TOTAL OF 2)

S E

C O

N D

T

IT

L E

S

B F

A

AIMAIM AIM AIM AIM

AIM AIM

AIM

AIM AIM

FA & SPKR

ROOM

SR CNSLR

MR2 CNSLR

TR

JAN

W. RSTRM

W. SHOWER

DIV RET.

CNSLR

DIV RET.

TEAM

FA & SPKR

MEDIA

CNSLR

M. SHOWER

M. RSTRM

SURGOEN

MEDIA

TEAM

EXTERIOR

MED OPS

DIV SURG.

PSYCHT

CH MED OPS

EXTERIOR

DIV RET.

ELECT

W. RSTRM

MECH

CORR

DIV ENG

TR

RAMP

ENG NCO

DIV ENG

PSYCTH

MEDIA

DIV SURGEON

CORR

TRIAL CNSL

DIV ENG

CHIEF ENG

RAMP

MEDIA

DIV-SJC

TRIAL CNSL

TRIAL CNSL

DIV-SJC

TEAM

TRIAL CNSL

TRIAL CNSL

CORR

DIV SJC

TRIAL CNSL

TRIAL CNSL

EXTERIOR

MECH

TV

FMCP WITH

MICROPHONE

FIP

TV

RAP

TV

FEP

TV

MEP

LOC

ANN

TV

P

C

1/2W 15

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W

1W

F

C

1/2W 75

C

1/2W 15

WP

1/2W

15WP

F

15WP

C

1/2W 30

C

1/2W 75

C

1/2W 30

C

1/2W 75 1W

WP

C

1/2W 30

C

1/2W 15

WP

1/2W F

15WP

C

1/2W

WP

F

15WP

C

1/2W

C

1/2W 30

C

1/2W 30

1/2W

1/2W

C

1/2W 75

C

1/2W 30

C

1/2W 30

C

1/2W 75

C

1/2W 75

C

1/2W 15

C

1/2W 75

C

1/2W 75

C

1/2W 75

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 75

C

1/2W 75

C

1/2W 30

C

1/2W

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

MWPWPWP

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

P P

2W WP 2W WP

WPWP WP WP WP

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30 2W 30

C

1/2W 15

C

1/2W 15

C

1/2W 30

C

1/2W 30

C

1/2W 75

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 15

C

1/2W 75

C

1/2W 75

C

1/2W 30

C

1/2W

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

P

1/2W C 2W WP

HS

PS

P

AOM

P

AOM

AOM

AOM AOM

COOPER WAVES 8 MASS

NOTIFICATION TRANSCEIVER

MONACO FIRE ALARM

TRANSMITTER

120/1/60 LOCATED AT PANEL

FA CKT#1 (1P20A BREAKER)

FOR CONT.

SEE

A

FOR CONT.

SEE

A

A

A

A

A

FOR CONT.

SEE

B

FOR CONT.

SEE

B

FOR CONT.SEE

SHEET FA602

C

B

B

B

B

120/1/60 LOCATED AT PANEL

FA CKT#2 (1P20A BREAKER)

120/1/60 LOCATED AT PANEL

FA CKT#3 (1P20A BREAKER)

120/1/60 LOCATED AT PANEL

FA CKT#4 (1P20A BREAKER)

FOR CONT.SEE

SHEET FA602

C

PROVIDE INPUT AND

OUTPUT MODULES FOR

THE SMOKE DAMPERS

PROVIDE INPUT AND

OUTPUT MODULES FOR

THE SMOKE DAMPER

PROVIDE INPUT AND OUTPUT MODULES

FOR THE SMOKE DAMPER

NOT TO SCALEA1

FIRE ALARM ONE LINE DIAGRAM

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H

I

18SB02

OF 173

FA601

F

IR

E A

L A

R M

O N

E L

IN

E

D

IA

G R

A M

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

A

AIM

AIM

AIM AIM

AIM

TRIAL CNSL

CORR

EXTERIOR

MEDIA

CHAPLAIN

ASST CHAPTL

PROT

CORR

CORR

VTC

CHAPLAIN

PA OFF

DIV PAO

CORR

DIV SAFETY

CHIEF CHAPL

BREAK

MEDIA

DIV PAO

MEDIA

OFFICE

SUPRVSR

TR

EXTERIOR

MECH

DCSM

COFS

CG

DIV G8

FILES

MECH

M

EXTERIOR

GO

S

CORR

W. SHOWER

CORR

ELECT

EXTERIOR

W. RSTRM

CORR

CBRN OFF

CBRN SGM

SPCL STAFF

CBRN NCO

DIV CBRNE

SCA

NCOIC

OIC

TEAM

MCP-OD

MEDIA

DIV CBRNE

MCP-OD

MEDIA

CORR

SECURITY

FA & SPKR

LOBBY

JAN

M. RSTRM

MECH

EXTERIOR

M. SHOWER

SIPRNET

EXTERIOR

TEAM

DIV CBRNE

C

1/2W 15

C

1/2W 15

C

1/2W 15

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 75

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 75

C

1/2W 75

C

1/2W 15

C

1/2W 75

C

1/2W 75

C

1/2W

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

P

1/2W C 1/2W C 2W WP 1/2W C1/2W C 1/2W C 1/2W C

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 75 2W 75 2W 75

C

1/2W 75

C

1/2W 75

C

1/2W 75

C

1/2W 75

C

1/2W

M

M

M

M

M

M

M

M

M

M

M

M

M

P P

2W WP 1/2W C

C

1/2W 75

C

1/2W 75

C

1/2W 30

C

1/2W 15

C

1/2W 30

C

1/2W 30

C

1/2W 15

C

1/2W 75 1W 75

C

1/2W

WP

M

M

M

M

M

M

M

M

M

M

PP

2W WP 2W WP

WP

WP

WP

C

1/2W 75

C

1/2W 30

C

1/2W 75

C

1/2W 75

C

1/2W 75

C

1/2W 75

C

1/2W 30

C

1/2W 75

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W 30

C

1/2W F

C

1/2W

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

C

1/2W 75

C

1/2W 30

C

1/2W 15

C

1/2W 15

C

1/2W 30

C

1/2W 75

C

1/2W 75 1W

M

M

M

M

M

M

M

M

P

1/2W C 1/2W C

1/2W C1/2W C 1/2W C 1/2W C

C

1/2W

M

C

1/2W

M

C1/2W

C

1/2W

M

C

1/2W

M

C

1/2W

M

1/2W C 1/2W C

C

1/2W

M

1/2W C

C

1/2W 75

C

1/2W

WP

C

1/2W

WP 2W

2W

M

M

M

M

MWP WP

P

2W WP

AOM

P

C

1/2W 30

C

1/2W 30

C

1/2W

M

M

M

2W WP

AOM

AOM AOM

AOM

C

C

C

C

FOR CONT.

SEE

D

FOR CONT.

SEE

D

FOR CONT.

SEE

E

FOR CONT.

SEE

E

E

E

E

E

FOR CONT.

SEE

F

FOR CONT.

SEE

F

D

D

D

D

FOR CONT.

SEE

G

FOR CONT.

SEE

G

G

G

G

G

F

F

F

F

BACK TO FIRE ALARM PANEL

BACK TO FIRE ALARM PANEL

BACK TO FIRE ALARM PANEL

BACK TO FIRE ALARM PANEL

PROVIDE INPUT AND OUTPUT MODULES

FOR THE SMOKE DAMPER

PROVIDE INPUT AND

OUTPUT MODULES

FOR THE SMOKE

DAMPER

PROVIDE INPUT AND

OUTPUT MODULES

FOR THE SMOKE

DAMPER

PROVIDE INPUT AND

OUTPUT MODULES

FOR THE SMOKE

DAMPER

NOT TO SCALEA1

FIRE ALARM ONE LINE DIAGRAM

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H I

18SB02

OF 173

FA602

F

IR

E A

L A

R M

O N

E L

IN

E

D

IA

G R

A M

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

A

EVACUATION

SIGNALS

AUXILIARY FUNCTIONS

TRANSMIT SIGNALS TO

THE FIRE DEPARTMENT

ANNUNCIATION AT

PANEL

* IN THE EVENT OF A CONFLICT BETWEEN THE

SPECIFICATIONS AND THE MATRIX, THE MATRIX SEQUENCE

WILL TAKE PRECEDENCE.

MASS NOTIFICATION SYSTEM ACTIVATION SHALL SILENCE ALL

FIRE ALARM OCCUPANT APPLIANCES UNTIL MASS SYSTEM IS

DEACTIVATED

SPRINKLER RISER OR FLOOR WATER FLOW OR PRESSURE SWITCH

MANUAL PULLSTATION

SMOKE DETECTOR

DUCT SMOKE DETECTOR

SPRINKLER VALVE TAMPER SWITCH

SINGLE BREAK OR GROUND FAULT IN FIRE ALARM CIRCUIT

MASS NOTIFICATION SYSTEM ACTIVATION (AUTO) (SEE NOTE NO.1)IN

IT

IA

T

IO

N

NOTE 1:

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

FIRE ALARM SYSTEM INPUT

S Y S T E M

O U

T P U

T S U

P E R

V

IS

O R

Y S

IG

N

A L

T R

O U

B

LE

S

IG

N A L

A C

T

IV

A T E V

IS

IB

LE

A

N D

A U

D

IB

LE

A

LA

R

M

A N

N U

N C

IA

T O

R

A C

T

IV

A T E V

IS

IB

LE

A

N D

A U

D

IB

LE

S U

P E R

V

IS

O R

Y A

N N

U N

C

IA

T O

R

A C

T

IV

A T E V

IS

IB

LE

A

N D

A U

D

IB

LE

T R

O U

B

LE

A N

N U

N C

IA

T O

R A C

T

IV

A T E A

LL

O

C C

U P A N

T N

O T

IF

IC

A T

IO

N

A P P

LI

A N

C E S

IN

T A K E F

IR

E A

LA

R

M P

R E -R

E C

O R

D E D

M E S S A G

E

(V

IS

U A L

D E V

IC

E S T

O R

E M

A

IN

O N

S O

U N

D

IN

G

A U

D

IB

LE

E

V A C

U A T

IO

N A

LA

R

M T

E M

P O

R A R

Y

A N

D

IM

M E D

IA

T E

LY

D E A C

T

IV

A T E A

LL

O C

C U

P A N

T N

O T

IF

IC

A T

IO

N A

P P

LI

A N

C E S

IN

IT

IA

T

IO

N D

E V

IC

E A

N D

O C

C U

P A N

T N

O T

IF

IC

A T

IO

N

A P P

LI

A N

C E S O

P E R

A T

IO

N M

A

IN

T A

IN

E D

S H

U T D

O W

N

IN

D

IV

ID

U

A L

A

IR

H A N

D

LI

N G

F A N

X

LOW BATTERY X XX

X X

XX

X

F

LO

W S

W

IT

C H

A C

T

IV

A T

IO

N

S M

O K E D

E T E C

T O

R A

C T

IV

A T

IO

N

T E M

P O

R A R

IL

Y D

E -A

C T

IV

E F

IR

E A

LA

R

M

S T R

O B E S A

N D

M E S S A G

E S

X

HVAC SHUTDOWN SWITCH X X X

C

LO

S E S

M O

K E D

A M

P E R

S

X

X

X

X

P U

LL

S

T A T

IO

N A

C T

IV

A T

IO

N

D U

C T D

E T E C

T O

R A

C T

IV

A T

IO

N

X

S H

U T D

O W

N A

LL

A

IR

H

A N

D

LI

N G

U N

IT

S

IN

B

NOT TO SCALEA1

SEQUENCE MATRIX OF OPERATIONS

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H

I

18SB02

OF 173

FA603

F

IR

E A

L A

R M

S E

Q U

E N

C E

M A

T R

IX

O

F O

P E

R A

T

IO

N S

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

A

TEMPERATURE RATINGS FOR ALL SPRINKLERS SHALL BE APPROPRIATE FOR THE LOCATION

IN ACCORDANCE WITH NFPA 13. PROVIDE QUICK RESPONSE SPRINKLERS THROUGHOUT THE

FACILITY UNLESS OTHERWISE NOTED. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED.

16. COORDINATE SPRINKLER LINE ROUTING WITH CEILING HEIGHTS AND OTHER

EQUIPMENT, DUCTS, AND PIPING IN THE CEILING. CONTRACTOR SHALL FOLLOW THE

PROPOSED MAIN ROUTING AS MUCH AS POSSIBLE. SPRINKLER PIPE TO BE

CONCEALED ABOVE CEILING S WHERE PRESENT.

PROVIDE LABELS AND VISIBLE IDENTIFICATION INDICATING LOCATION OF ALL FLOOR

CONTROL VALVES, INSPECTOR'S TEST STATIONS; AND FIRE DEPARTMENT

CONNECTIONS.

15.

14. ALL EXTERIOR SPRINKLER HEADS SHALL BE ELECTROLESS NICKEL PTFE (ENT).

13. PROVIDE INSPECTION AND HYDROSTATIC TEST AND SUBMIT CONTRACTOR'S MATERIAL

AND TEST CERTIFICATES FOR ABOVE GROUND AND UNDERGROUND PIPING IN

ACCORDANCE WITH NFPA 13. PRIOR TO HYDROSTATIC TEST, THE CONTRACTOR SHALL

PERFORM AN AIR PRESSURE TEST TO LOCATE ANY POTENTIAL LEAKAGE.

FIRE SPRINKLER SYSTEM NOTES:

1. FIRE SPRINKLER SYSTEM SHALL COMPLY WITH NFPA 13, NFPA 13R, NFPA 24, AND THE

CONTRACT SPECIFICATIONS.

ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED.10.

11.

12.

FIRE PROTECTION GENERAL NOTES:

PROPERLY FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS,

OR PARTITIONS WITH A UL APPROVED SYSTEM APPROPRIATE FOR THE

PENETRATION TYPE AND FIRE RATING IN ACCORDANCE WITH MANUFACTURER'S

INSTALLATION INSTRUCTIONS. FIRE STOP ALL PENETRATIONS BETWEEN FLOORS.

4.

3.

2.

1.

FIRE PROTECTION UNDERGROUND NOTES:

THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS

OF THE NATIONAL FIRE PROTECTION ASSOCIATION CODE, NATIONAL ELECTRICAL

CODE, AND ALL OTHER AGENCIES HAVING JURISDICTION.

THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER THE COMPLETE

INSTALLATION OF SYSTEMS TO FUNCTION AS DESCRIBED AND SPECIFIED. THE

OMISSION OF REFERENCE TO ANY NECESSARY ITEM OF LABOR OR MATERIAL SHALL

NOT RELIEVE THE CONTRACTOR FROM PROVIDING SUCH LABOR AND MATERIAL.

ALL EQUIPMENT SHALL BE CAPABLE OF FITTING INTO THE SPACES ALLOCATED

WHILE MEETING THE MANUFACTURER'S RECOMMENDED ACCESS

REQUIREMENTS. REVIEW ALL SPACES WHERE EQUIPMENT IS TO BE INSTALLED

PRIOR TO ORDERING OF EQUIPMENT AND NOTIFY THE CONTRACTING OFFICER

OF ANY INADEQUATE CLEARANCES OR CONDITIONS THAT WILL PREVENT THE

PROPER INSTALLATION, MAINTENANCE, AND OPERATION OF THE EQUIPMENT.

PROVIDE SHOP DRAWINGS FOR THE LAYOUT OF FIRE SPRINKLER AND FIRE

ALARM SYSTEMS SHOWING COORDINATION OF ALL WORK WITH ALL OTHER

TRADES, INCLUDING PLUMBING, AIR CONDITIONING, CONTROLS, ELECTRICAL

AND COMMUNICATION SYSTEMS. COORDINATION DRAWINGS SHALL OVERLAY

HVAC, PLUMBING, FIRE SPRINKLER, ELECTRICAL AND FIRE ALARM SYSTEMS,

AND ALL CONFLICTS BETWEEN TRADES SHALL BE NOTED AND RESOLVED.

VERIFY AND COORDINATE ALL ROOF, WALL AND FLOOR PENETRATIONS WITH

THE STRUCTURAL AND ARCHITECTURAL DRAWINGS AND NOTIFY THE GENERAL

CONTRACTOR OF ANY CONFLICTS PRIOR TO START OF CONSTRUCTION.

OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING ANY

PENETRATIONS THROUGH STRUCTURAL MEMBERS, WALLS AND SLABS.

TONE AND LOCATE ALL UTILITY LINES OR OTHER INTERFERENCES IN AREAS OF

PROPOSED TRENCH WORK PRIOR TO START OF EXCAVATION. REPAIR OR PAY

FOR ALL DAMAGES TO EXISTING UTILITIES.

DRAWINGS DO NOT ATTEMPT TO SHOW EXACT DETAILS OF PIPING. PROVIDE

OFFSETS AS NECESSARY TO AVOID LOCAL OBSTRUCTIONS OR INTERFERENCE

WITH OTHER TRADES. REVIEW ALL PIPING AND DUCT RUNS PRIOR TO

FABRICATION AND IMMEDIATELY NOTIFY THE GENERAL CONTRACTOR OF ANY

INTERFERENCE AND/OR LACK OF ADEQUATE CLEARANCES.

SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK, MARK

SUCH CHANGES ON THE AS-BUILT DRAWINGS AND NOTIFY THE GENERAL

CONTRACTOR. IF THESE CHANGES REQUIRE ALTERNATE METHODS TO THOSE

APPROVED BY THE CONTRACT DOCUMENTS, SUBMIT SHOP DRAWINGS SHOWING

THE PROPOSED ALTERNATE METHODS TO THE GENERAL CONTRACTOR FOR

REVIEW. DO NOT PROCEED UNTIL REVIEWED.

REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION RESULTING FROM THE

INSTALLATION OF MECHANICAL ITEMS. THE AREAS REPAIRED SHALL MATCH

THE ADJACENT SURFACES IN TEXTURE AND COLOR.

SEISMICALLY BRACE ALL EQUIPMENT AND PIPING IN ACCORDANCE WITH THE

SPECIFICATIONS. PROVIDE ZONE-OF-INFLUENCE CALCULATIONS

1.

2.

4.

3.

6.

5.

10.

9.

8.

7.

12.

11.

UNDERGROUND FIRE PROTECTION WATER LINE DESIGN AND INSTALLATION SHALL BE IN

ACCORDANCE WITH NFPA 24 AND THE SPECIFICATIONS.

ALL DEVICES AND EQUIPMENT SHALL BE LISTED IN UL FPED OR FM P7825a FOR

UNDERGROUND FIRE SERVICE.

PIPING SHALL BE DUCTILE IRON WITH A RATED WORKING PRESSURE OF 150 PSI

CONFORMING TO AWWA C151, WITH CEMENT MORTAR LINING CONFORMING TO

AWWA C104. MINIMUM BURIAL DEPTH OF PIPE SHALL BE 3 FEET.

PROVIDE PROPER THRUST RESTRAINT AT ALL CHANGES IN DIRECTION OF PIPE.

LOCATION: FROM RFP DOCUMENTS

FLOW AT RESIDUAL PRESSURE

RESIDUAL PRESSURE

STATIC PRESSURE

WATER SUPPLY AT TIME OF DESIGN4.

8.

7. PROVIDE EARTHQUAKE PROTECTION (SWAY BRACING) IN ACCORDANCE WITH NFPA 13.

USE A HORIZONTAL FORCE FACTOR OF HALF THE WEIGHT OF THE WATER FILLED

PIPE.

PROVIDE SURGE RESTRAINT CLIPS ON ALL HANGAR RINGS USED IN END OF BRANCH

LINE RESTRAINT. PROVIDE END OF BRANCH RESTRAINT FOR ALL BRANCH LINES OVER

4 FEET OR WHERE SUBJECT TO DAMAGE OR WHERE UPWARD OR LATERAL MOVEMENT

OF THE SYSTEM PIPING WOULD RESULT IN DAMAGE TO THE SPRINKLER THROUGH

IMPACT AGAINST THE BUILDING STRUCTURE, EQUIPMENT, OR FINISH MATERIALS.

SPRINKLER PIPING SHALL BE: ACCORDANCE WITH SPECIFICATIONS

ALL DRAINS AND EXTERIOR PIPING SHALL BE COPPER OR EPOXY COATED SCHEDULE 40 BLACK STEEL.

THE CONTRACTOR SHALL COMPLY WITH OSHA 29 CFR 1910.36 AND 29 CFR 1910.37.

THE FIRE SPRINKLER SYSTEM SHOWN IS CONCEPTUAL . THE EQUIPMENT IS SHOWN IN

SUGGESTED LOCATIONS, FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE WITH

APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTING.

SHOP SUBMITTALS SHALL SHOW SPRINKLER DETAILS IN ACCORDANCE WITH NFPA 13 AND

THE MANUFACTURER'S EQUIPMENT LISTING INSTALLATION REQUIREMENTS.

2.

5. SPRINKLER DESIGN REQUIRED PRESSURE (RESIDUAL) SHALL BE BASED ON A MINIMUM

10% OR 10 PSI SAFETY FACTOR, WHICH EVER IS GREATER

ACCORDANCE WITH THE FOLLOWING CRITERIA:

THE WET-PIPE SYSTEM SHALL BE HYDRAULICALLY DESIGNED AND INSTALLED IN6.

AUTOMATIC SPRINKLER PROTECTION IS REQUIRED THROUGHOUT THE ENTIRE BUILDING

IN ACCORDANCE WITH NFPA 13.

3.

17. PROVIDE SPRINKLER GUARDS ON THE SPRINKLER HEADS IN ELECTRICAL ROOMS,

STORAGE ROOMS, TELECOM ROOMS, AND MECHANICAL ROOMS.

9.

18.

1400 GPM

32 PSI

70 PSI

LIGHT HAZARD (OFFICES, CORRIDORS, COMMON ROOMS, RESTROOMS, AND DWELLING UNITS )

DESIGN DENSITY: .10 GPM/sf LIGHT HAZARD

DESIGN AREA: 1500 sf

HOSE STREAM: 250 GPM

DURATION: 60 MINUTES

SPRINKLER: QUICK RESPONSE CONCEALED PENDENT AND SIDEWALL SPRINKLERS. USE

RESIDENTIAL CONCEALED PENDENT AND SIDEWALL SPRINKLERS FOR DWELLING UNITS.

ORDINARY HAZARD GROUP 1 (MECHANICAL, STORAGE, JANITORIAL, AND ELECTRICAL)

DESIGN DENSITY: .20 GPM/sf ORDINARY HAZARD

DESIGN AREA: 2500 sf OR LARGEST ROOM

HOSE STREAM: 250 GPM

DURATION: 60 MINUTES

SPRINKLER: QUICK RESPONSE UPRIGHT AND PENDENT

PROVIDE LABELS AND VISIBLE IDENTIFICATION INDICATING LOCATION OF ALL FLOOR

CONTROL VALVES, INSPECTOR'S TEST STATIONS; AND FIRE DEPARTMENT

CONNECTIONS.

19. LOCATE ALL FIRE PROTECTION RISER PIPING AT LEAST 12' FORM ANY EXTERIOR

WALL FOR BLAST SAFETY.

THE CONTRACTOR SHALL PAINT THE FIRE SPRINKLER PIPES RED AND SHALL

PROVIDE PAINTING LABELS ON THE PIPE, SEE SPECIFICATIONS FOR MORE MORE

INFORMATION ON THE LABELING.

COORDINATE CONNECTION OF THE FIRE SPRINKLER SUPERVISORY DEVICES WITH

THE FIRE ALARM CONTRACTOR. THE FIRE SPRINKLER CONTRACTOR SHALL PROVIDE

THE FLOW AND TAMPER SWITCHES AND THE FIRE ALARM CONTRACTOR SHALL

INSTALL AND CONNECT TO THE FIRE ALARM SYSTEM.

20.

21.

POWDER ACTUATED FASTENERS, SHOT PINS, AND EXPANSION BOLTS LESS THAN 1/2"

IN DIAMETER SHALL NOT BE PERMITTED IN EXISTING PRECAST CONCRETE ROOF

MEMBERS SUCH AS INVERTED T-GRIDERS, RECTANGULAR BEAMS, AND WEB OR STEM

PORTIONS OF DOUBLE T-GRIDERS. SEE ROOF FRAMING PLANS ON STRUCTURAL

DRAWINGS.

13.

THE PROJECT AND SPECIFICATIONS SHALL REFERENCE THE USAC ENGINEERING

MANUAL (EM), EM-385-1-1 AND NFPA 241, 2013 EDITION AND SHALL FOLLOW THE

REQUIREMENT OF THE INSTALLATION'S FIRE REGULATIONS.

14.

PORTABLE FIRE EXTINGUISHERS SHALL COMPLY WITH NFPA 10 AND SPECIFICATIONS.

ALL FIRE EXTINGUISHERS SHALL HAVE A MINIMUM CLASS 4A:60B:C RATING &

SHALL BE DRY CHEMICAL TYPE UNLESS NOTED OTHERWISE.

FIRE EXTINGUISHER NOTES:

1.

2.

THE CONSTRUCTION (SHOP) DRAWINGS AND CALCULATIONS MUST BE PREPARED BY,

OR PREPARED UNDER THE IMMEDIATE SUPERVISION OF THE QFPE. THE QFPE MUST

AFFIX THEIR PROFESSIONAL ENGINEERING STAMP WITH SIGNATURE TO THE SHOP

DRAWINGS, CALCULATIONS AND MATERIAL DATA SHEETS, INDICATING APPROVAL

PRIOR TO SUBMITTING THE FIRE EXTINGUISHING SYSTEM SHOP DRAWINGS TO THE

DFPE. THE QFPE MUST MONITOR THE INSTALLATION OF THE FIRE PROTECTION

SYSTEMS AND CERTIFY IN WRITING THAT THE FIRE PROTECTION SYSTEMS HAVE BEEN

CONSTRUCTED AND OPERATE AS INTENDED IN THE DESIGN PLANS AND

SPECIFICATIONS.

15.

TYP.

FDC

F

WET-PIPE FS RISER

FIRE SPRINKLER PIPING

SPRINKLER CROSS MAIN END CAP

TYPICAL

FIRE DEPARTMENT CONNECTION

POC POINT OF CONNECTION

FIRE SPRINKLER LEGEND

DESCRIPTIONABBRV.SYMBOL

FS FIRE SPRINKLER

TS TAMPER SWITCH

GATE VALVEGV

OS&Y OUTSIDE STEM AND YOKE

FLOW SWITCHFSFS

INDICATING BUTTERFLY VALVE-

MAIN DRAIN DISCHARGE

NORMALLY CLOSEDN.C.

FLOOR CONTROL ASSEMBLYFCA

TS

PS ALARM PRESSURE SWITCHPS

LEGEND

LIGHT HAZARD: CORRIDORS,

OFFICES, COMMON ROOMS,

RESTROOMS.

DESIGN

DENSITY

OCCUPANCY CLASSIFICATION

.10 GPM/SF

DESIGN

AREA

1500 SF

MAX. SPRINKLER

SPACING

HOSE

ALLOWANCE

250 GPM

DURATION

60 MIN.225 SF

ORDINARY HAZARD:

MECHANICAL ROOMS,

ELECTRICAL ROOMS, JANITOR

ROOMS, STORAGE ROOMS.

.20 GPM/SF 2500 SF 250 GPM 60 MIN.130 SF

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H

I

18SB02

OF 173

FX001

F

IR

E S

P R

IN

K

L E

R N

O T

E S

A N

D L

E G

E N

D

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

X

E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

EXIST. FIRE HYDRANT

SEE SHTS. FX101 AND FA101 FOR

THE BLDG. 2091 NEW FIRE

SPRINKLER AND FIRE ALARM/MASS

NOTIFICATION WORK

B2091

6" FS RISER W/ BACKFLOW

PREVENTER SEE SHEET

FX101 FOR

CONTINUATION

6" FS MAIN FOR CONT.

SEE CIVIL DWGS.

FIRE DEPT. AND TEST HEADER

CONNECTION MONUMENT WITH

FIRE DEPARTMENT

CONNECTION, SEE CIVIL SHEET

C-503 FOR DETAILS AND FINAL

LOCATION

F I R

E D

E P

T . A

C C

E S

S R

D

4" FDC/TEST HEADER

MAIN TO MONUMENT.

FOR CONT. SEE CIVIL

DRAWINGS

WATER GONG

NEW FIRE HYDRANT SEE CIVIL

FOR MORE DETAIL

PROVIDE CHECK VALVE ON

THE VERTICAL PIPE FOR THE

FDC CONNECTION

PROVIDE GATE VALVE ON

THE VERTICAL PIPE FOR THE

TEST HEADER CONNECTION.

VALE SHALL BE CHAINED AND

LOCKED.

GENERAL NOTES:

1. FIRE DEPARTMENT CONNECTION SHALL BE WITHIN

150 FEET OF THE NEAREST FIRE HYDRANT. FIRE

DEPARTMENT SHALL BE PLACED ON THE EDGE OF

THE SIDEWALK BEHIND THE EXISTING 3 FOOT HIGH

WALL IN FRONT OF THE PARKING LOT. FIRE

HYDRANT SHALL BE CLEARLY VISIBLE.

2. THE FIRE HYDRANT SPACING IS WITHIN 350 FEET.

3. THE BACKFLOW PREVENTER SHALL BE INSTALLED

ON THE FIRE SPRINKLER RISER.

4. THE POST INDICATING VALVE SHALL BE PROVIDED

BY CIVIL.

5. THE MONUMENT SHALL BE INSTALLED WITHIN 20

FEET FROM THE FIRE DEPARTMENT ACCESS ROAD.

DN DN

DN

DN

DN

DN

DN

DN

DN

DN

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H I

18SB02

OF 173

FS101

F

IR

E S

P R

IN

K

L E

R S

I T E

P L A

N

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

1" = 20'-0"A1

FIRE SPRINKLER SITE PLAN

S E

C O

N D

T

IT

L E

S

B F

S

E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

DN

UP

DN

DN

DN

DN

REF.

AA

BB

CC

DD

EE

FF

LOBBY

FIRE ALARM &

SPKR

SECURITY

CORR

SIPRNET

TEAM

MEDIA

SCA

CBRN NCO

CBRN SGM

CBRN OFF

OIC

NCOIC

MECH

WOMEN

RESROOM

M SHOWER

MEN RESROOM

WOMEN

RESROOM

CORR

COFS

TR

DIV PAO

OFFICE

TEAM

MEDIA

148 PA OFF

VTC

BREAK

PROT

CHAPLAIN

MEDIA

CHIEF CHAPL

ASST CHAPL

CORR

TEAM

MEDIA

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

TRIAL CNSL

MECH

CHIEF ENG

ENG NCO

TR

MEDIA

PSY CHT

CORR

DIV SURGEON

PSYCHT

178SURGOEN

MEDIA

TEAM

CH MED OPS

MED OPS

MECH

DIV RETENSION

TEAM

MEDIA

CNSLR

CNSLR

SR CNSLR

MR2 CNSLR

TR

ELECT

JAN

WOMEN

RESROOM

MEN RESTROOM

WOMEN SHOWER

MEN SHOWER

6" FIRE SPRINKLER RISER

WITH WATER GONG FOR

DETAIL B1 ON SEE SHEET

FX501

6"

6"

6" FIRE MAIN, SEE

CIVIL FOR CONT.4"

TO FIRE DEPARTMENT AND

TEST HEADER CONNECTION

MONUMENT. SEE CIVIL FOR

CONTINUATION

HAZARD CATEGORY

LIGHT HAZARD

ORDINARY HAZARD

PROVIDE FIRE SPRINKLER

COVERAGE IN ACCORDANCE WITH

NFPA 13 AND UFC 3-600-01 FOR ALL

AREAS INSIDE THE BOUNDARY

CMD CNSLR

CG

DCSM

DIV G8

M

S

GO

ELECT

JAN

SPCL STAFF

CORR

MECH

DIV CBRNE

DIV SAFTY

SUPRVSR

MEDIA

DIV SJC-CRIMLAW

RAMP

Room

MCP-OD

MEDIA

TEAM

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H I

18SB02

OF 173

FX101

F

IR

E S

P R

IN

K

L E

R N

E W

W O

R K

P L A

N

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

3/32" = 1'-0"A1

FIRE SPRINKLER NEW WORK PLAN

S E

C O

N D

T

IT

L E

S

B F

X

O E

S P

N E

C L O

O E

S E N

P C L O

NOTES:

1. PROVIDE SPRINKLER PIPE CLEARANCES IN ACCORDANCE

WITH NFPA 13.

PLASTIC WATERPROOF

CEMENT IN NON-FIRE

RATED WALLS (TYP)

SPRINKLER

WHEN BELL RINGS

CALL

FIRE DEP'T OR POLICE

FIRE ALARM

NOTES:

1. SIGN SHALL BE MOUNTED ADJACENT TO FIRE

ALARM BELL.

2. SIMILAR WORDING ON WATER MOTOR ALARM GONG

SHALL BE ACCEPTABLE INSTEAD OF A SEPERATE SIGN.

MINERAL WOOL

BATT INSULATION

(TYP)

STEEL SLEEVE,

AS REQUIRED WALL ASSEMBLY

(CONCRETE, CMU,

OR GYPSUM BOARD)

6" RISER

PROVIDE FOUR WAY SEISMIC

BRACE AT TOP OF RISER

FLEXIBLE GROOVED

COUPLING (TYP)

PRESSURE GAGE W/

COCK (TYP)

WATER OPERATED ALARM GONG

LOCATED OUTSIDE OF BUILDING

ALARM CONTACTOR

(PRESSURE SWITCH)

PLUG COCK WITH

LEVER

RETARD CHAMBER

DRIP CUP

ANGLE VALVE (TYP)

DRAIN TO GRADE

ALARM VALVE

24"

MAX.

6"x6"x4" TEE

FIRE SPRINKLER

ALARM SIGN, SEE

OS & Y GATE VALVE

MANUAL SHUT-OFF

W/ SEAL SHUT-OFF &

TAMPER SWITCH

DOUBLE CHECK

VALVE

TO FDC/TEST

HEADER MONUMENT

SEE SHEET C-503

FOR DETAIL ON THE

MONUMENT

TS

TS

THRUST BLOCK

FLEXIBLE COUPLING

12"

FLOOR LINE

3/4" BITMUS COATED

TIE RODS

D3

FS501

(WET PIPE SYSTEM)

**NOTES:

PROVIDE 1" INSPECTORS TEST AND

DRAIN WITH PRESSURE RELIEF VALVE

THE TEST HEADER SHALL BE ROUTED

UNDERGROUND TO THE TEST HEADER MONUMENT

1. THE FIRE DEPARTMENT CONN. SHALL BE ROUTED

UNDERGROUND TO THE FDC MONUMENT

SEE CIVIL DRAWINGS FOR THE DETAIL ON THE

FIRE DEPARTMENT CONNECTION MONUMENT

3.

2.

PROVIDE ANNULAR CLEARANCE PER NFPA

13 REQUIREMENTS. PROVIDE SLEEVE PER

SPECIFICATION 21 13 13.00 10.

SCALE: NOT TO SCALE

FIRE SPRINKLER RISER DETAIL

B1

SCALE: NOT TO SCALE

SPRINKLER FIRE ALARM SIGN DETAIL

D3

SCALE: NOT TO SCALE

TYPICAL PIPE AND CONDUIT THRU WALL DETAIL

C3

No. FP 001359

R E G

IS

T E

R

ED

PRO

FESS IONAL

EN

G

IN

E E R

B A R R

Y G .S .

J

IM

O N

F I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O

NF

I R

E

P R O T E C T

I O N

S T A

T E

OF CA L I F

O R

N I A

SIGNATURE

JUNE 30, 2019

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B J

IM

O N

W A

-1 -D

-0

H O

N O

L U

L U

D

IS

T R

IC

T

F O

R T

S H

A F

T E

R H

A W

A

II

U

L R

IC

H

W A

Y

S C

H O

F

IE

L D

B A

R R

A C

K S

O

A H

U H

I

IN

S

Y N

E R

G Y

E N

G

IN

E E

R I N

G

IN

C

F

O R

T S

T R

E E

T M

A L L S

U

IT

E

H

O N

O L U

L U

H

I

18SB02

OF 173

FX501

F

IR

E S

P R

IN

K

L E

R D

E T

A

IL

S

R S

U S

T E

R

R S

U S

T E

R

B J

IM

O N

M

A Y

RTA SUBMITTAL, DBB, 7 MAY 2018

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

S E

C O

N D

T

IT

L E

S

B F

X

D

COTG; FCO

PLUMBING LEGEND

SYMBOL ABBREV. DESCRIPTION

SANITARY SOIL, SEWER OR WASTE PIPING BELOW FLOOR OR GRADESS OR W

VENT PIPINGV

CW COLD WATER PIPING

CLEANOUT; WALL CLEANOUTCO; WCO

CLEANOUT TO GRADE; FLOOR CLEANOUT

CONDENSATE DRAIND

CONTINUATIONCONT.

EXISTING SANITARY SOIL, SEWER OR WASTE PIPING BELOW FLOOR OR GRADE(E)SS OR

(E)W

EXISTING VENT PIPING(E)V

(E)CW EXISTING COLD WATER PIPING

EXISTING(E) OR

EXIST.

AIR-HANDLING UNITAHU

HW HOT WATER PIPING

FD FLOOR DRAIN

DOWNDN.

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

PLUMBING LEGEND

SYMBOL ABBREV. DESCRIPTION

HOSE BIBBHB

LAV LAVATORY

ACCESSIBLE LAVATORYA-LAV

S.P. STATIC PRESSURE

T&P TEMPERATURE & PRESSURE RELIEF VALVE

U.C. UNDER CUT

UNION

VTR VENT THRU ROOF

WITHW/

WC WATER CLOSET

ACCESSIBLE WATER CLOSETA-WC

SHOWERSH

URINALUR

POINT-OF-CONNECTIONP.O.C.

POINT-OF-REMOVALP.O.R.

ACCESSIBLE URINALA-UR

SHEETSHT.

ACCESSIBLE SHOWERA-SH

GENERAL NOTES:

1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS PRIOR TO FABRICATION, INSTALLATION

AND COMMENCEMENT OF ALL WORK TO BE PERFORMED. COORDINATE ALL WORK TO BE

PERFORMED WITH OTHER TRADES. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER

OF ANY MAJOR DEVIATIONS OR DISCREPANCIES IN THE PLANS AND SPECIFICATIONS.

2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER THE COMPLETE

INSTALLATION OF SYSTEMS TO FUNCTION AS DESCRIBED AND SPECIFIED. THE OMISSION

OF REFERENCE TO ANY NECESSARY ITEM OF LABOR OR MATERIAL SHALL NOT RELIEVE

THE CONTRACTOR FROM PROVIDING SUCH LABOR AND MATERIAL.

3. ALL EQUIPMENT SHALL BE CAPABLE OF FITTING INTO THE SPACES ALLOCATED WHILE

MEETING THE MANUFACTURER'S RECOMMENDED ACCESS/CLEARANCE REQUIREMENTS.

4. VERIFY AND COORDINATE ALL WALL, FLOOR AND ROOF PENETRATIONS.

5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES AND FIELD

CONDITIONS AFFECTED BY THIS INSTALLATION PRIOR TO, COMMENCING AND DURING

CONSTRUCTION.

6. TONE AND/OR SCOPE TO LOCATE EXISTING UNDER SLAB WASTE AND VENT PIPING TO

VERIFY LOCATION PRIOR TO SAW CUTTING OF EXISTING CONCRETE SLAB.

7. TONE AND LOCATE ALL UTILITY LINES OR OTHER INTERFERENCES IN AREAS OF

PROPOSED TRENCH WORK PRIOR TO START OF EXCAVATION.

8. DRAWINGS DO NOT ATTEMPT TO SHOW EXACT DETAILS OF PIPING AND DUCTWORK.

PROVIDE OFFSETS AS NECESSARY TO AVOID LOCAL OBSTRUCTIONS OR INTERFERENCE

WITH OTHER TRADES. REVIEW ALL PIPING AND DUCT RUNS PRIOR TO FABRICATION AND

IMMEDIATELY NOTIFY THE CONTRACTING OFFICER OF ANY INTERFERENCE AND/OR LACK

OF ADEQUATE CLEARANCES.

9. SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK, MARK SUCH

CHANGES ON THE AS-BUILT DRAWINGS. IF THESE CHANGES REQUIRE ALTERNATE

METHODS TO THOSE APPROVED BY THE CONTRACT DRAWINGS, SUBMIT SHOP DRAWINGS

SHOWING THE PROPOSED ALTERNATE METHODS TO THE CONTRACTING OFFICER FOR

REVIEW. DO NOT PROCEED UNTIL REVIEW.

10. POWDER ACTUATED FASTENERS, SHOT PINS, AND EXTENSION BOLTS LESS THAN 1/2"

IN DIAMETER SHALL NOT BE PERMITTED IN EXISTING PRECAST CONCRETE ROOF MEMBERS

SUCH AS INVERTED T-GIRDERS, RECTANGULAR BEAMS, AND WEB OR STEM PORTIONS OF

DOUBLE T-GIRDERS. SEE ROOF FRAMING PLANS ON STRUCTURAL DRAWINGS.

M

W

PROFESSIONAL

A

S H

A

SIIA , .U

N

ENGINEER

No. 7624-M

LICENSED

.A

YU

.K H

This work was prepared by me or under my supervision.

US Army Corps of Engineers ®

SHEET OF

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

17384

P-001

18SB02

PL

U

M

BI

N G

L E G

EN

D

U

LR

IC

H

W

AY

SC

H O

FI

EL

D B

AR

R

AC

KS

, O

AH

U , H

I H

O N

O L U

LU

D

IS

TR

IC

T

F O R

T

SH

AF

TE

R , H

AW

AI

I

M C

E

IN

TE

R

N

AT

IO

N

AL

, I

N C

S

. B

ER

ET

AN

IA

S

TR

EE

T

ST

E

H

O N

O

LU

LU

, H

AW

AI

I 9

D N

JA SHD

N

M

AY

. W

A-

-D

-0

SHFI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

RTA SUBMITTAL, DBB, 7 MAY 2018

R

EN

O

VA

TI

O

N O

F

BU

IL

D

IN

G

. 18

SB

P-

EXIST. 2" CW TO

REMAIN, FOR POINT

OF REMOVAL IN

BLDG., SEE

REMOVE EXIST. PLUMBING

FIXTURES & ASSOCIATED

WASTE, VENT & WATER

PIPING WITHIN THIS AREA,

UNLESS NOTED OTHERWISE

EXIST. 4" WASTE LINE

TO REMAIN, FOR POINT

OF REMOVAL IN

BLDG., SEE

EXIST. 4" WASTE

LINE TO REMAIN,

FOR POINTOF

REMOVAL IN

BLDG., SEE

EXIST. 6" WASTE

LINE TO REMAIN

EXIST. 4" WASTE

LINE TO REMAIN

EXIST. 4" CW TO

REMAIN, CAP IN

WALL

REMOVE EXIST.

ABANDONED GAS

PIPING, CUT & CAP

6" ABOVE FLOOR

REMOVE EXIST.

ABANDONED GAS

PIPING ALONG WALL

IN IT'S ENTIRETY

EXIST. FOS & FOR

PIPING TO REMAIN,

CAP IN WALL

P-402

EXIST. COTG

TO REMAIN

P-102

POINT OF

REMOVAL

EXIST. FCO

TO REMAIN

P-402

WOMENS

7A

MEN'S

7B

ADCO

CORRIDOR

CLASSROOM

131WAITING

CIVILIAN

ACPL

CPC

STOR

STOR

17A

STOR

COMPUTER RM

INSTRUCTOR

CONTRACT

COORDINATOR

PREVENTION

CORRIDOR

PREVENTION

ASSISTANT

BREAK ROOM

WAITING

MILITARY

TESTING

CIVILIANTOILET

AIBTC

STAFF

COFFEE AREA

FTDTL

BOOTH

TOILET

TOILET

STORAGE

SECURED

STORAGE

STORAGE

STAFF

TOILET

STAFF

JAN

ELECT

LUNCH ROOM

PROGRAM

OFFICE

14B

OFFICE

14A

CLASSROOM #2

ACS

CLASSROOM #1

ACS

PROGRAM

LC STORAGE

19D

LC STORAGE

19E

LC STORAGE

19C

CLOSET

LENDING

CLOSET

19A

LENDING

LC STORAGE

19B

IVC

READINESS

FINANCIAL

ACS

6A

CHIEF

OFFICE

16R

OFFICE

OFFICE

LOBBY

STORAGE

AER FILES

16F

CORRIDOR

4A

CORRIDOR

PROGRAM

ADVOCACY

FAMILY

PROGRAM

ADVOCACY

FAMILY

READINESS

STORAGE

I&R FILES

MGR

I&R

BREAK

2A

COMM

16S

OFFICE

8A

STORAGE

133A

COMM

11E

TOILET

11D

OFFICE

11A

OFFICE

11B

OFFICE

11C

STOR

11F

HALL

11J

FAMILY

STOR

11G

CORRIDOR

4B

CORRIDOR

OFFICE

8E

OFFICE

8D

OFFICE

8C

JAN

7C

ELECT

8B

OFFICE

9A

OFFICE

9B

STOR

11H

MEMBER

FAMILY

EXCEPTIONAL

OFFICE

16A

OFFICE

16B

OFFICE

16C

OFFICE

16D

OFFICE

16E

STORAGE

17B

A A

B

C

D

E

F

B

C

D

E

F

2 3 4 5 6 7 8

3 4 5 6 7 8 9 10 11

2322212019181716

20191817161514

UP

UP

DNDN

DN

DN

DN

DN

DN

M

W

PROFESSIONAL

A

S H

A

SIIA , .U

N

ENGINEER

No. 7624-M

LICENSED

.A

YU

.K H

This work was prepared by me or under my supervision.

US Army Corps of Engineers ®

SHEET OF

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

17385

PD101

18SB02

D

EM

O

LI

TI

O

N P

L U M

BI

N

G F

LO

O

R P

LA

N

U

LR

IC

H

W

AY

SC

H O

FI

EL

D B

AR

R

AC

KS

, O

AH

U , H

I H

O N

O L U

LU

D

IS

TR

IC

T

F O R

T

SH

AF

TE

R , H

AW

AI

I

M C

E

IN

TE

R

N

AT

IO

N

AL

, I

N C

S

. B

ER

ET

AN

IA

S

TR

EE

T

ST

E

H

O N

O

LU

LU

, H

AW

AI

I 9

D N

JA SHD

N

M

AY

. W

A-

-D

-0

SHFI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

RTA SUBMITTAL, DBB, 7 MAY 2018

R

EN

O

VA

TI

O

N O

F

BU

IL

D

IN

G

3/32" = 1'-0"1 DEMOLITION PLUMBING FLOOR PLAN

SB

PD

M

W

PROFESSIONAL

A

S H

A

SIIA , .U

N

ENGINEER

No. 7624-M

LICENSED

.A

YU

.K H

This work was prepared by me or under my supervision.

UP

UP

DN

REF.

UP

F.E.C

FD FD

SPCL STAFF

FILES

MEDIA

PA OFF

149 CHAPLAIN

CHIEF CHAPL

ASST CHAPL

VTC

DIV PAO

DIV SAFTY

SUPRVSR

MECH

OFFICE

DCSM

CG

130 COFS

DIV G8

M

S

CORR

PROT

BREAK

MCP-OD

OIC

TEAM

MEDIA

ELECT

W RESTROOM

M RESTROOM

M SHOWER

MECH

CBRN OFF

CBRN SGM

CBRN NCO

SCA

NCOIC

MEDIA

TEAM

LOBBY

DIV CBRNE

TR

SECURITY

SIPRNET

CO

RR

CO

RR

P-401

NEW 2 1/2" CW

LINE AT CEILING

M

AT

C H

L

IN

E, F

O R

C O

N

TI

N U

AT

IO

N S

EE

D

W G

. P -1

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

P-13

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

P-12

(P-12)

P-12

P-12

P-12

GO

CORR

JAN

MEDIA

3/4" HOSE BIBB

W/ VACUUM

BREAKER & SHUT-

OFF VALVE

BALL VALVE

REDUCED PRESSURE

BACKFLOW

PREVENTOR

PRESSURE

REGULATING VALVE

WATER METER

1" CW LINE DN.

BELOW GRADE

3/4" CW LINE TO

EXPANSION TANK

AT CHILLER

P-11

3/4" HOSE BIBB

W/ VACUUM

BREAKER & SHUT-

OFF VALVE

3/4" HOSE BIBB

W/ VACUUM

BREAKER & SHUT-

OFF VALVE

AA

BB

CC

DD

EE

FF

US Army Corps of Engineers ®

SHEET OF

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

17386

P-101

18SB02

N

EW

P L U

M

BI

N G

F L O

O R

P

LA

N

D

O M

ES

T I

C

U

LR

IC

H

W

AY

SC

H O

FI

EL

D B

AR

R

AC

KS

, O

AH

U , H

I H

O N

O L U

LU

D

IS

TR

IC

T

F O R

T

SH

AF

TE

R , H

AW

AI

I

M C

E

IN

TE

R

N

AT

IO

N

AL

, I

N C

S

. B

ER

ET

AN

IA

S

TR

EE

T

ST

E

H

O N

O

LU

LU

, H

AW

AI

I 9

D N

JA SHD

N

M

AY

. W

A-

-D

-0

SHFI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

RTA SUBMITTAL, DBB, 7 MAY 2018

R

EN

O

VA

TI

O

N O

F

BU

IL

D

IN

G

1/8" = 1'-0"1

NEW PLUMBING FLOOR PLAN 1 -

DOMESTIC

KEY PLAN

NOT TO SCAL

SB

P-

PROFESSIONAL

A

S H

A

SIIA , .U

N

ENGINEER

No. 7624-M

LICENSED

.A

YU

.K H

This work was prepared by me or under my supervision.

DN

DN

UP

FD

CORR

DIV SJC-CRIMLAW

TEAM

MECH

CHIEF ENG

TRIAL CNSL

TRIAL CNSL

DIV SJC-CRIMLAW

TRIAL CNSL

TRIAL CNSL

ELECT

W RESTROOM

M RESTROOM

PSYCHT

TEAM

MECH

MED OPS

183 CH MED OPS

CNSLR

CNSLR

190SR CNSLR

MR2 CNSLR

TR

CMD CNSLR

DIV RETENSION

MEDIA

MEDIA

WOMEN SHOWER

MEN SHOWER

TRIAL CNSL

TRIAL CNSL

FIRE ALARM &

SPKR

JAN

CO

RR

CO

RR

P-401

2 1/2" CW

LINE AT

CEILING

M

AT

C H

L

IN

E, F

O R

C O

N

TI

N U

AT

IO

N S

EE

D

W G

. P -1

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

2 1/2" CW LINE, FOR

CONT. & COORDINATION

SEE CIVIL DWG.

2 1/2" CW LINE DN.

BELOW CONC.

WALKWAY

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

3/4" HOSE BIBB W/

VAC. BREAKER &

SHUT-OFF VALVE

2 1/2" CW

LINE, FOR

CONTINUATION

SEE 1/P-101

1/2" HW LINE, FOR

CONTINUATION

SEE 1/P-101

P-12

P-12

P-12

P-12

MEDIA

RAMP

P-12

TRIAL CNSL

168 PSY CHT

TEAM

LOBBY

SURGEON

SURGEON

DIV

ENGINEER

DIV

AA

BB

CC

DD

EE

FF

MEDIA

ENG NCO

US Army Corps of Engineers ®

SHEET OF

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

17387

P-102

18SB02

N

EW

P L U

M

BI

N G

F L O

O R

P

LA

N

D

O M

ES

T I

C

U

LR

IC

H

W

AY

SC

H O

FI

EL

D B

AR

R

AC

KS

, O

AH

U , H

I H

O N

O L U

LU

D

IS

TR

IC

T

F O R

T

SH

AF

TE

R , H

AW

AI

I

M C

E

IN

TE

R

N

AT

IO

N

AL

, I

N C

S

. B

ER

ET

AN

IA

S

TR

EE

T

ST

E

H

O N

O

LU

LU

, H

AW

AI

I 9

D N

JA SHD

N

M

AY

. W

A-

-D

-0

SHFI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

RTA SUBMITTAL, DBB, 7 MAY 2018

R

EN

O

VA

TI

O

N O

F

BU

IL

D

IN

G

1/8" = 1'-0"1

NEW PLUMBING FLOOR PLAN 2 -

DOMESTIC

KEY PLAN

NOT TO SCALE

SB

P-

PROFESSIONAL

A

S H

A

SIIA , .U

N

ENGINEER

No. 7624-M

LICENSED

.A

YU

.K H

This work was prepared by me or under my supervision.

UP

UP

DN

REF.

F.E.C

FD FD

P-402

EXIST. 4" WASTE LINE

BELOW FLOOR SLAB

M

AT

C H

L

IN

E, F

O R

C O

N

TI

N U

AT

IO

N S

EE

D

W G

. P -1

P-13

2" CO

UNDERSINK

CG

COFS

DIV G8

DCSM

S

M

MECH

W RESTROOM

M RESTROOM

121 M SHOWER

W SHOWER

SPCL STAFF

DIV CBRNE

CBRN OFF

CBRN SGM

CBRN NCO

SIPRNET

LOBBY

SECURITY

DIV CBRNE

SCA

MEDIA

TEAM

MCP-OD

112NCOIC

OIC

TEAM

114 MEDIA

CORR

MEDIA

CHAPLAIN

PA OFF

MEDIA

FILES

147OFFICE

MECH

SUPRVSR

TR

DIV SAFTY

PROT

ASST CHAPL

CHIEF CHAPL

VTC

DIV PAO

2" WASTE LINE

BELOW FLOOR SLAB,

FOR CONTINUATION

SEE DWG. 1/P-104BREAK

EXIST.