55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf

PDF 557 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 55-TPF FFE

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
1-V1.04_SURVEY_PLAN.pdf PDF
49_25__TPFV4.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
55_TQ3.11C_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_C.pdf PDF
55_TQ3.11_-_FFE_PLAN_-_TPF_PHASE_1.pdf PDF
55_TQ4.11C_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_C.pdf PDF
49_24__TPF3.0_Full_Luminary_Plan.pdf PDF
49_23__TCP1.2_Combined_Clinic_TPF_RCP.pdf PDF
49_23__TCP1.0_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ3.11B_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_B.pdf PDF
49_24__TPF7.0_Overall_Plumbing_Plan_-_D.W.V.pdf PDF
49_25__TPFV3.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_25__TPFV5.0_STANDARD_CANOPY_DETAILS_STAMPED.pdf PDF
49_24__TPF2.1-P2_Full_Building_Plan_Phase_2.pdf PDF
29_06_TNX1.0_Building_Cross_Section.pdf PDF
43_16_TCCA1.0_Exterior_Elevations.pdf PDF
36_10_TSP3.0-PII_Plumbing_Plan_-_Supply_Phase_2.pdf PDF
07_E0-02_-_SYMBOL_LEGEND_AND_GENERAL_NOTES.pdf PDF
36_09_TSA2.0_Floor_Plan.pdf PDF
36_11_TSE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_02_TNA4.0_Egress_Plan.pdf PDF
36_09_TSA3.0_Reflective_Ceiling_Plan.pdf PDF
29_03_TNP2.0_Plumbing_Schematics.pdf PDF
43_16_TCCA4.0_Egress_Plan.pdf PDF
43_17_TCCE1.0_Elec_Plan.pdf PDF
29_04_TNE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_05_TNM1.0_Mechanical_HVAC_Plan.pdf PDF
36_10_TSP4.0-PII_Plumbing_Plan_-_DWV_Phase_2.pdf PDF
36_10_TSP1.0_Plumbing_Schematics.pdf PDF
36_09_TSA1.0_Exterior_Elevations.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_19Aug19.pdf PDF
29_04_TNE4.0_MDP_-_One_Line_Diagram.pdf PDF
05_1-CU1.02_UTILITY_PLAN_-_PHASE_2_AND_3.pdf PDF
29_03_TNP3.0_Plumbing_Plan.pdf PDF
08_T1.10_-_TELECOM_SITE_PLAN_-_CONSTRUCTION_PHASE.pdf PDF
43_17_TCCE2.0_Illumination_Plan.pdf PDF
29_02_TNA2.1_Interior_Elevations.pdf PDF
Attachment_H_-_TPF_Placement_Area.pdf PDF
36_09_TSA4.0_Egress_Plan.pdf PDF
36_08_TSC1.0_Cover_Sheet.pdf PDF
36_11_TSE1.0_Electrical_Plan.pdf PDF
43_18_TCCM1.0_MECHANICAL_HVAC_PLAN.pdf PDF
08_T6.05-TECHNOLOGY_SITE_RISER_DIAGRAM.pdf PDF
36_13_TSX1.0_Building_Cross_Section.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_13Aug19.pdf PDF
Attachment_C_-_AFMSA_Design_Guidance.pdf PDF
Attachment_B_-_Utility_Plans.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation.pdf PDF
Attachment_G_-_PFD_TYNDALL_TPF_v2_20190702.pdf PDF
Attachment_E_-_Installation_Facility_Standards_&_Plans.pdf PDF
Tyndall_TMMF_Statement_of_Work_10Jul19.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TV

TV

TV

+72"

A.F.F.

J

E-4

+72"

A.F.F.

GFI

G F I

REFRG

G F I

GFI

G F I

G F I

GFI

GFI

GFI

G F I

GFI

G F I

G F I

G F I

+72"

A.F.F.

GFI

+72"

A.F.F.

G F I

G F I +72"

A.F.F.

R E F R

IG

R E F R

IG

R E F R

IG

REFRIG

GFI

+48"

A.F.F.

+48"

A.F.F.

+48"

A.F.F.

+48"

A.F.F.

+72"

A.F.F.

+72"

A.F.F.

REFRIG

GFI

GFI

GFI

REFRIG

GFI

TV

TV

TV

TV

TV

48"GFI

GFI GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI

+72"

A.F.F.

+72"

A.F.F.

+72"

A.F.F.

+72"

A.F.F.

GFI

+72"

A.F.F.

+72"

A.F.F.

+72"

A.F.F.

+72"

A.F.F.

GFI

+72"

A.F.F.

GFI

GFI

PLAN NORTH

BMET

P-106

CLR01

CENTRAL

STORAGE

K-112

SRS01

SHARED NCOIC

OFFICE

K-110

OFA02

OIC OFFICE

K-111

OFA02

IDMT EXAM

ROOM

C-108a

EXRG3

TECH

A-511

OFA03

TECHNICIAN

OFFICE

INTERVIEW

COMMUNITY

HEALTH

D-110

OFA01

DEPLOYMENT

MED OFFICE

D-115

OFA05

TECH

C-113c

OFA03

TECH OFFICE

INTERVIEW

COMM HEALTH

D-104

OFA01

RECORDS FIXED

SHELVING

A-516

MRS01

TECH OFFICE

INT OCC

HEALTH

D-103

OFA05

COPY DISTRO

FILES

D-102a

RPR01

WAITING

C-101

WRC01

COPY DISTRO

FILES

C-102a

RPR01

IDMT TECH

C-113a

OFA03

AUDIO TESTING

D-106

PEHS1

RECEPTION

C-102

RECP1

PROVIDER

OFFICE OIC

C-111

OFA02

IDMT TECH

C-113b

OFA03

PHA INTERVIEW

ROOM NCOIC

D-108

OFDC2

TREATMENT

ROOM

C-121

TRGM1

PROVIDER

OFFICE

C-117a

OFA02

STAFF

LOUNGE_TEAM

CONFERENCE

ROOM

C-109

SL002

PHA INTERVIEW

ROOM

D-111

OFDC2

EXAM ROOM

C-108

EXRG3

PROVIDER

OFFICE

C-114

OFA02

PHA INTERVIEW

ROOM

D-109

OFDC2

EXAM ROOM

C-107

EXRG3

PROVIDER

OFFICE

C-112

OFA02

CLEAN UTILITY

C-110

UCCL1

PHA

DEPLOYMENT

MED EXAM

ROOM

D-116

EXRG3

EXAM ROOM

C-105

EXRG3

PROVIDER

OFFICE

C-115

OFA02

SOILED UTILITY

C-120

USCL1

COUNSELING

ROOM

D-113

OFDC2

EXAM ROOM

C-103

EXRG3

NCOIC OFFICE

C-124

OFA02

EXAM ROOM

C-106

EXRG3

NURSE

WORKROOM

C-122

OFA05

OIC OFFICE

D-119

OFA02

EXAM ROOM

C-104

EXRG3

MEDICAL

STANDARDS

OFFICE MSME

C-116

OFA05

WAITING

D-101

WRC01

PUBLIC HEALTH

CENTER

D-107

OFA02

MULTI-DIAGNOSTIC

ROOM

C-123

PEVS1

PHA

TECHNICIAN

WORKSTATION

C-118a

OFA03

RECEPTION

D-102

RECP1

PHA

TECHNICIAN

WORKSTATION

C-118b

OFA03

TECH OFFICE

INT FORCE

HEALTH MGMT

D-105

OFA01

SHPE OFFICE

INTERVIEW

C-125

OFA04PROVIDER

OFFICE

C-117

OFA02

NCOIC OFFICE

D-118

OFA02

STAFF TOILET

A-110

TLTU1

LPN OFFICE

D-117

OFA02

FOLDED

EYE-LANE

E-105

EYEL4

FITTING AND

DISPENSING

AREA

E-116

EYFD1

FRAME

CONTACTS

STORAGE AREA

E-114

SRS01

VISUAL FIELD

E-111

EYVF1

OPTOMETRIST

OFFICE

E-110

OFD03

OPTOMETRIST

OFFICE

E-112

OFD03

WAITING

E-101

WRC01

RECEPTION

E-102

RECP1

VISUAL

SCREENING

E-103

EYVS1

COPY DISTRO

FILES

E-102a

RPR01

MULTI-DIAGNOSTIC

ROOM

E-106

EYVF1

STAFF TOILET

E-115

TLTU1

MULTI-DIAGNOSTIC

ROOM

E-104

EYVF1

FULL EYE-LANE

E-108

EYEL1

FULL EYE-LANE

E-109

EYEL1

FOLDED

EYE-LANE

E-107

EYEL4

SUB-WAITING

E-113

WRC01

TECH

WORKSTATION

E-116a

OFA03

TOILET

A-111

COMM ROOM

D-114

COMC1

ELECTRICAL

ROOM

D-112

MECH1

JANITOR

A-112

JANC1

MICROBIOLOGY

K-107

M TLT

A-103

F TLT

A-105

STAFF TOILET

A-109

TLTU1

JAN

K-106

JANC1

CORE LAB

K-105

LBSC1

COPY DISTRO

FILES

K-104a

RPR01

SHIPPING

RECEIVING

K-108

LBSS2

TECH

K-105b

OFA03

TECH

K-105a

OFA03

RECEPTION

K-104

RECP1

WAITING ROOM

K-101

WRC01

TECHNICAL

SUPERVISOR

K-109

OFA02

BLOOD

DRAWING AREA

K-103

LBVP1

SPECIMEN

TOILET

K-102

TLTU1

STAFF

LOUNGE_CONFERENCE

ROOM

A-108

SL002

STAFF TOILET

A-107

TLTU1

STAFF

LOUNGE_CONFERENCE

ROOM

A-106

SL002

WAITING

G-101

WRC01

VACANT

G-104

EXRG3

OFFICE

G-106

OFA02

STORAGE

G-107

SRCS1

PATIENT STAFF

TOILET

G-109a

TLTU1

BEE WORK

ROOM

G-103

PTES1

OFFICE

G-102a

PTBT1

STORAGE

G-103a

PTTC1

COMM ROOM

A-102

COMC1

JANITOR

A-104

JANC1

STAFF

LOUNGE_CONFERENCE

ROOM

B-104

SL002

STAFF TOILET

SHR

B-103

TLTS1

ON-CALL ROOM

B-105

DUTY1

ON-CALL ROOM

B-106

DUTY1

STORAGE

B-102

SRS01

NCO OFFICE

-SHARED-

B-101

OFA05

KITCHEN

B-104a

SL002

JANITOR

G-108

JANC1

TECH

C-113d

OFA03

STORAGE

C-117b

PATIENT STAFF

TOILET

G-109b

TLTU1

OFFICE

G-109C

LAB

G-105

VACANT

FIT

G-103c

VACANT

STORAGE

P-101

VACANT

BMET STORAGE

P-104

VACANT

VACANT

HSMR STORAGE

FFE PHASING

FFE TRANSITION

COMPLETED IN PHASE 1

MOVE. RE: TQ1.11A

L

IT

T L

E R

O C

K D

IV

IS

IO

N

L

IT

T L

E R

O C

K

A R

K A

N S

A S

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A

54321

B

C

D

E

54321

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M

J E

D U

N N

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

/2 /2

JE DUNN + HWA

NATIONAL HEALTHCARE DEISGN-BUILD TEAM

R E

V

IS

E D

C O

R R

E C

T E

D F

IN

A

L

06/28/1706/28/1706/28/1706/28/17

/2

/2

:4

:1

A

M

A s in di ca te d

C U s e rs

\k e lly

.w h it n e y \D o c u m e n ts

\1 A

M

A T

O C

T y n d a ll

A F

B T

P F

P h a s e k e lly

.w h it n e y .r v t

F F

E P

L A

N

T P

F P

H A

S E

T Y

N D

A

LL

A F

B

TQ4.11

S T

R E

E T

N A

M E

C

IT

Y , S

T A

T E

H O

E F

E R

W Y

S O

C K

I

D S

B M

A K

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

4'0 8' 16' 1/8" = 1'-0"A1

OVERALL FURNITURE AND EQUIPMENT PLAN

- PHASE 2

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

Sheets
TQ4.01 - FFE JSN LEGEND
TQ4.11 - FFE PLAN - TPF PHASE 2
TQ4.11C - FFE PLAN - TPF PHASE 2, AREA C
TQ4.11D - FFE PLAN - TPF PHASE 2, AREA D

File details come from the government source that posted it.